Movitrac LTE B

The ideal solution for simple applications

Page 2: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B

Only 40 Parameters for ease of useBuilt in keypad and displayKeyhole mountings for ease of installationUp to 50°C Ambient TemperatureInternal RFI Filter for EMC compliance150% Overload for 60 Seconds32kHz Output Switching Frequency for ultra quiet motor operation Optional Optistick for fast parameter copying

AC Variable Speed Drive0.37-11kW / 0.5-15HP

Page 3: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B Additional Features

Integrated control unit with 6-digit display

Integrated brake transistor for size 2 and 3

Helpcard with default wiring and basic parameters

Preset for motors with same power rating

Integrated DIN rail mounting

SBus interface via RJ45-connector

Modification for IT systems possible

Page 4: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B

Simple Conveyors, eg. in agricultural environment

Fans and pumps

Simple pumps e.g. wine pumps

Traditional applications Not suitable for more complex applications

Page 5: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B Part No.s

• Additional Features of LTE B eg options

Page 6: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B Sizes & Ratings

mains voltagerating size 1

[kW]rating size 2

[kW]rating size 3

[kW]

110 … 115V, 1ph 0.37 0.75 1.1 -

200 ... 240V, 1ph out

0.37 0.75 1.1

220 … 240V, 1ph 0.37 0.75 1.5 1.5 2.2 4.0

220 … 240V, 3ph 0.37 0.75 1.5 1.5 2.2 4.0

380 … 480V, 3ph 0.75 1.5 1.5 2.2 4.0 5.5 7.5 11(only IP20)

Page 7: Movitrac LTE B The ideal solution for simple applications

MOVIDRIVE B• 3 x 230V, 3 x 500V

Basic inverter Standard inverter Application inverter

Functionality

Pri

ce

MC07B• 3 x 230V• 3 x 500V

MOVITRAC LT• 1 x 110V • 1/3 x 240V • 3 x 480V• 3 x 575V

Movitrac LTE B Placement in SEW portfolio

Page 8: Movitrac LTE B The ideal solution for simple applications

MOVITRAC® LTE B• 1 x 115V 0.37…1.1kW• 1/3 x 230V 0.37...4.0kW• 3 x 400V 0.75…7.5kW(11kW)

MOVITRAC® LTP• 1/3 x 230V 0.37... 90kW• 3 x 400V 0.75..160kW• 3 x 575V 0.75…45kW

Pri

ce

Functionality

Movitrac LTE B Placement in SEW portfolio

Page 9: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B Additional Features

Overload capability

150 % for 60 s

175 % for 2 s

Cable length

shielded: 25 – 100 m

unshielded: 40 – 150 m

Maximum cable length depends on drive size

Page 10: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B Additional Features

Helpcardlist of drive parameters& terminal layout

RJ45 connectorFor SBusand start up

Key holesFor easy mechanical installation

7-digit displayand keypad build in as standard

11 Terminals3x DI1x AI1x AO/DO1x Relay (eg. for brake)

Intuitive Power terminals

40 Parameters14 basic26 extended

Braking resistor Connection at size 2 and size 3

Mounting railfor size 1 and 2

Page 11: Movitrac LTE B The ideal solution for simple applications

DIN mounting rail

Size 1 and 2 drives are designed to mount directly onto DIN rail if required

Removal by releasing catch at bottom of drive

When size 1 and 2 are mounted side by side, the keypads are level for ease of operation and monitoring

Page 12: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B Additional Features

Display

Start

Reset/Stop

Navigate

Up

Down

Navigate

Long press into/ out of parameter programming

Short press to view/ store parameter values

Up / Down

Increase/ decrease the value of the parameter or the speed

Start

Enable running of motor

Stop / Reset

Stop motor/ reset trip

Page 13: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B Additional FeaturesAccessories / Options

IP55 / Nema 12k housing

EMC filter externally

Input choke

Output choke

Braking resistor

Parameter module

External keypad

PI controller card

Second analog output

Second relay output

SEW Gateways

RJ45-cabel splitter

Page 14: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B Optistick

Infra red communications for programming with PDA or Smartphone

Status LEDLED on: Power on Flashing LED: Data transfer

Simply insert Optistick into the RJ45 slot in front

side of the MOVITRAC ® LTE B

Upload/download buttons allow fast copying of parameters between drives

Page 15: Movitrac LTE B The ideal solution for simple applications

LT Shell CE

Pocket PC Software for LTE-B (and LTP)

Designed for Windows Mobile 5

Parameter transfer to / from drive

Product configuration

Language support

Export to settings to WORD/text file

display mode

descriptions

parameter list

Movitrac LTE B Software

Page 16: Movitrac LTE B The ideal solution for simple applications

LT Shell

PC Software for LTE-B (and LTP)

Designed for Windows

Parameter transfer to / from drive

MOVITRAC LTE-B configuration

Local MOVITRAC LTE-B control

Language support

Export to settings to WORD/text file

Movitrac LTE B Software

Page 17: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B Communications

Gateway Slave 1 Slave 2 Slave 3

1m 3m0.3m

0.3m

0.3m

0.3m

Termination resistor

Works with all SEW Gateways and PLC from version 2030

Cables, splitter and bus termination available

Up to 8 drives in a network

Page 18: Movitrac LTE B The ideal solution for simple applications

Energy optimizer

For energy saving, the energy optimizer (P-06) can be enabled

The drive automatically reduces the applied motor voltage (hence torque) depending on the load conditions

The advantage of this control over a variable torque characteristic (traditionally used) is that a higher starting torque can be achieved

If boost is applied the function then has limited capability on the low speed range as the boost function has priority.

V

f

Page 19: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B Housing

Cabinet housingIP20

Field duty housingIP55 / NEMA 12k

Page 20: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B Enclosed Version

FWD/Off/REV switch

programmable in drive

Local potentiometer

Power isolation switch

with lock off capability

3 frame sizes up to 7.5kW / 10 HP

IP55/NEMA 12K

Wall mountable

Resists low-pressure water,

dust, dirt and chemicals

Rugged industrial 40°C ambient rating for hot and tough applications

Conduit cable entry

Small mechanical size

Keypad Control

Integral RFI filter option

Switched or non-switched variants

Page 21: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B Enclosed

IP55/Nema 12 enclosure prevents dust and moisture ingressEnclosure designed to resist the effects of most chemicals and lubricantsWash down duty IP55/NEMA 12 Wall or machine mountable Compact Mechanical SizeIntegral RFI FilterAmbient temperature up to 40°C with no deratingConduit cable entry Switched or non switched

AC Variable Speed Drive0.37-7.5kW / 0.5-10HP

Page 22: Movitrac LTE B The ideal solution for simple applications

Movitrac LTE B 2nd Generation Enclosed

Lightweight, compact ‘Flat Plate’ design for easy OEM integration High Pressure Washdown duty IP66/NEMA4X for indoor use Specially Coated heatsinks to protect against corrosion Dust tight seals to prevent water, oil & dust entering the enclosure No external Fans to replace Switched versions onlyRapid programming with Optistick & Optiwand PDA Rugged industrial 40°C ambient ratingOptional built-in RFI/EMC Filter S-bus communication as standard

AC Variable Speed Drive0.37-7.5kW / 0.5-10HP

Page 23: Movitrac LTE B The ideal solution for simple applications

Adaptation of Movitrac LTE B drive

Dedicated to control of single phase motors:

Permanent Split CapacitorShaded Pole

Special Boost Starting Cycle

Movitrac LTE B Single Phase Output