1
MOTOR VIBRATION DIAGNOSTIC CHART PROBLEM SYMPTOMS COLD-NO COLDWARM SECURE PHASE LOADED LOADED POWER 1X RPM ROUGH NO CHANGE NO CHANGE DROPS SOLID SLOWL Y AIR GAP'* ., 2X LINE ROUGH INCREASES INCREASES IMMEDIATE N/A . DROP . 2X LfNE ROUGH INCREASES INCREASES IMMEDIATE N/A ,. DROP 2X LINE ROUGH INCREASES INCREASES IMMEDIATE' 'N/A " . DROP > ROTOR BAR I X WITH SMOOTH INCREASES INCREASES NO CHANGE RAPiD . OSCILLATIONS ROUGH INCREASES INCREASES IMMEDIA TE RAPID 1X WITH DROP OSCILLATIONS SHORTED 1X WITH SMOOTH INCREASES INCREASES DROPS ST ATIC SHIFT SIDEBANDS SLIGHTLY SIGNIFICANTL Y soft foot check. # Eliminate Softfoot and Airgaps first. I

Upload: dilkisuno

Post on 15-Nov-2015

216 views

Category:

Documents


1 download

DESCRIPTION

motor vibration diagnsis basic

TRANSCRIPT

  • MOTOR VIBRATION DIAGNOSTIC CHART

    PROBLEM

    SYMPTOMSCOLD-NOCOLDWARMSECUREPHASELOAD

    LOADEDLOADEDPOWERUNBALANCE

    1X RPMROUGHNO CHANGENO CHANGEDROPSSOLID

    SLOWL YSTATOR AIR GAP'*., 2X LINEROUGHINCREASESINCREASESIMMEDIATEN/A

    FREQ

    . DROP$OFTfQOT *

    . 2X LfNEROUGHINCREASESINCREASESIMMEDIATEN/A

    ,FREQ

    ,. DROP

    .L~OOSEIRON #

    2X LINEROUGHINCREASESINCREASESIMMEDIATE' 'N/A" .

    FREQ

    DROP

    ROTOR

    >

    ROTOR BARI X WITHSMOOTHINCREASESINCREASESNO CHANGE RAPiD

    SIDEBANDS

    . OSCILLATIONSECCENTRIC

    ROUGHINCREASESINCREASESIMMEDIA TERAPID

    ROTOR

    1X WITH DROPOSCILLATIONS

    SIDEBANDS SHORTED

    1X WITHSMOOTHINCREASESINCREASESDROPSST ATIC SHIFT

    IRON

    SIDEBANDS SLIGHTLYSIGNIFICANTL Y

    * Confirm usingtorsional measurementsand soft foot check.#EliminateSoftfoot andAirgaps first.

    I