mono-blocktm ii+ - honeywell · mono-blocktm ii+ the mono-block ii+ is the building block for both...

4
Mono-Block TM II+ The Mono-Block II+ is the building block for both smart and slave injector solutions. The new Mono-Block™ II+ represents the latest generation of Honeywell Enraf’s MBII, the industry’s most widely used additive injector, installed at more than 75,000 load racks, pipelines, chemical storage and distribution facilities and aviation fuel delivery facilities around the world. Built upon the identical footprint and utilizing identical electronic components as the MBII, it is differentiated by numerous mechanical enhancements and unique patent pending features. Mono-Block II+ is designed to work seamlessly with Honeywell Enraf’s Smart injector controllers (Mini-Pak 3000, Mini-Pak 6 and new Fusion4 SSC) or as a slave unit with latest generation loading presets and Terminal Automation Systems. The compact assembly features a solid block design manufactured in 303 stainless steel. A patent pending pressure relief feature prevents possible injector damage during the calibration operation. An integral adjustable needle valve in the discharge port of the block provides for precise flow regulation for unparalleled additive control.

Upload: lamdien

Post on 11-Oct-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Mono-BlockTM II+ - Honeywell · Mono-BlockTM II+ The Mono-Block II+ is the building block for both smart and slave injector solutions. The new Mono-Block™ II+ represents the latest

Mono-BlockTM II+

The Mono-Block II+ is the building block for both smart and slave injector solutions.ThenewMono-Block™II+representsthelatestgenerationof

HoneywellEnraf’sMBII,theindustry’smostwidelyusedadditive

injector,installedatmorethan75,000loadracks,pipelines,

chemicalstorageanddistributionfacilitiesandaviationfuel

deliveryfacilitiesaroundtheworld.Builtupontheidentical

footprintandutilizingidenticalelectroniccomponentsasthe

MBII,itisdifferentiatedbynumerousmechanicalenhancementsanduniquepatentpending

features.Mono-BlockII+isdesignedtoworkseamlesslywithHoneywellEnraf’sSmart

injectorcontrollers(Mini-Pak3000,Mini-Pak6andnewFusion4SSC)orasaslaveunitwith

latestgenerationloadingpresetsandTerminalAutomationSystems.Thecompactassembly

featuresasolidblockdesignmanufacturedin303stainlesssteel.Apatentpendingpressure

relieffeaturepreventspossibleinjectordamageduringthecalibrationoperation.Anintegral

adjustableneedlevalveinthedischargeportoftheblockprovidesforpreciseflowregulation

forunparalleledadditivecontrol.

Page 2: Mono-BlockTM II+ - Honeywell · Mono-BlockTM II+ The Mono-Block II+ is the building block for both smart and slave injector solutions. The new Mono-Block™ II+ represents the latest

Benefits

• Operationalsecuritywithtamperprooffeatures

• SeamlessintegrationontoexistingpanelsandracksasfootprintisidenticaltoMBII

• Provenreliability,greaterthan75,000MBIIinjectorsinstalledworldwide

• Proveneaseofmaintenanceandcalibration

• ExtremelyaccuratewithunparalleledtreatrateoptimizationwhenusedwithFusion4SSC,andexistingMiniPakand

BlendPakcontrollers

Features

• 303Stainlesssteelblock.

• 3/8”FNPTinletandoutletports

• Inletandoutlettaperedplugstyleisolationvalveswith180°operation

• Allenwrenchaccessboltstoprovidetamperresistance

• Valvecoverplateswithsealwirescrewsforaddedsecurity

• Patentpendingthermalreliefdevice

• Allenadjustableintegralneedleforpreciseflowthrottling

• Ovalgearmetercavitymachinedintoblock.

• Strainerbasketpositionedperpendiculartoflowinfaceofblock

• SSballcheckvalve,machinedandpolishedtoachieveoptimumsealing

• Meter,solenoid,mountingholesandcomponentheightsareidenticaltolegacyMBIIensuringseamlessintegration

• NewMaleTestPortP/N10-50000-SWK

• NewCalibrationKitP/N10-31565-SWK

• Explosionproofsolenoidmachinedintoblock

• ExplosionproofHall-Effectmetersensor

General Arrangement

Page 3: Mono-BlockTM II+ - Honeywell · Mono-BlockTM II+ The Mono-Block II+ is the building block for both smart and slave injector solutions. The new Mono-Block™ II+ represents the latest

Flow

NominalK-Factor : 5000PPG

MeterAccuracy : 0.50%

MeterRepeatability : 0.25%

MaxFlowRate : 2.5gal/Min(9.5Liters/Min)

MinFlowRate : 0.1gal/Min(0.38Liters/Min)

MaxPressure : 400psi(27.6Bar)

MaxViscosity : 300cst.

Environmental

Temperature : -28ºCto65ºC(-20ºFto150ºF)

Approvals : ExplosionproofcomponentsratedforClass1,Div1GroupC&D

Materials

Manifold : 303StainlessSteel

MeterGears : 538RytonTM

Sensor : Aluminum

SolenoidSeals : Chemraz

Electrical

SolenoidVoltage : 120/240VAC 22W/11W;50/60Hz

(ConsultFactoryfor12VDCor24VDC)

Sensortype : Solid-state,bi-polarmagneticgated,opencollectoroutput

Sensorpower : 5-25VDC,20mAmaximum

OpenCollectorOutput : 5–25VDC,100mAmaximum(un-sourced)

Mechanical

ManifoldComponents : Outletflowcontrol&divertervalve,Inletstrainer,

Outletcheckvalve,QRCcalibrationpoint.

ManifoldConnections : 3/8”FNPT

Weight

BareMono-BlockIIunmounted: 5kg(11lbs)approx

Options

Ovalgearmaterial : StainlessSteel

Calibration : Mono-BlockTMCalibrationKit(P/N10-31565-SWK)

Technical Specification

Page 4: Mono-BlockTM II+ - Honeywell · Mono-BlockTM II+ The Mono-Block II+ is the building block for both smart and slave injector solutions. The new Mono-Block™ II+ represents the latest

Identification Code

EN-10-06-US_Rev.01May 2012© 2012 Honeywell International Inc.

For More InformationTolearnmoreaboutHoneywellEnraf’ssolutions,contactyourHoneywellEnrafaccountmanagerorvisitwww.honeywellenraf.com.

AmericasHoneywellEnrafAmericas,Inc.2000NorthfieldCt.Roswell,GA30076USAPhone:+17704751900Email:[email protected]

Europe, Middle East and AfricaHoneywellEnrafDelftechpark392628XJDelftTheNetherlandsPhone:+31(0)152701100Email:[email protected]

Asia PacificHoneywellPteLtd.17ChangiBusinessParkCentral1Singapore486073Phone:+6563552828Email:[email protected]

Pos 1, 2, 3 Manufactured Product9 0 - Mono-BlockII+Multi-PakFamilyofinjectorblocks

Pos 4 Operating Voltage0 120VAC50/60Hz1 240VAC50/60Hz9 Special

Pos 5 Wetted parts material0 OptionalTeflonSolenoidSeatwithotherstandardsales1 StandardChemrazsolenoidseat2 HighresistantOption-SSgears,HighresistantElastomers9 Special

Pos 6 Meter resolution1 RytonGears-5000PPG(Nominal)4 StainlessSteelGears-5000PPG(Nominal)9 Special

Pos 7 Electrical and certifications0 ULlistedelectricalcomponents9 Special

Pos 8 Configuration0 BareMono-BlockII+unmounted1 Fullsizepanelwith1MBII+InjectorBlockwithroomfor5more2 Fullsizepanelwith2MBII+InjectorBlockswithroomfor4more3 Fullsizepanelwith3MBII+InjectorBlockswithroomfor3more4 Fullsizepanelwith4MBII+InjectorBlockwithroomfor2more5 Fullsizepanelwith5MBII+InjectorBlockwithroomfor1more6 Fullsizepanelwith6MBII+InjectorBlocks9 Special

Pos 9, 10, 11 Control options0 0 0 SlaveInjectorswithterminalstripsinenclosureM P 6 AdderforMP6electroniccontrollerinenclosure

9 0 - 1 1 1 0 6 M P 6 Typical identification code

9 0 - Your identification code