Clearswift Public
Monitoring Clearswift Gateways with SCOM
Technical Guide
Version 01
28/11/2014
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
Documentation Information
File Name Monitoring the gateways with SCOM_v1.docx
Document Author Iván Blesa
Document Filename Monitoring the gateways with SCOM_v1.docx
Issue 01
Classification Public
Document Change Control
Version Date Name Change Description
01 28/11/201 Iván Blesa First version
Document Approval
Name Role Signature Date
Approval
Approval
Approval
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
Contents
1 Introduction ............................................................................... 4
2 Scope ....................................................................................... 4
3 Configuration and Setup ................................................................. 5
3.1 Overview .............................................................................. 5
3.2 Installation ............................................................................ 5
3.2.1 Create a Linux user account for the monitoring service .................. 5
3.2.2 Sudoers file configuration ..................................................... 6
3.2.3 Iptables configuration(Linux firewall) ....................................... 6
3.2.4 Allowing SSH access ............................................................ 7
3.2.5 Verify DNS – forward and reverse lookup .................................... 7
3.2.6 Import Management Packs ..................................................... 8
3.2.7 Create a monitoring resource pool ......................................... 10
3.2.8 Configure Runas accounts and profiles .................................... 11
3.2.9 Configure Gateways to monitor ............................................. 16
4 Monitoring the Gateways .............................................................. 19
5 Troubleshooting ......................................................................... 22
5.1 No SSH access ...................................................................... 22
5.2 Incorrect account privileges ...................................................... 22
5.3 Incorrect management pack imported .......................................... 23
5.4 General troubleshooting .......................................................... 23
6 FAQ – Frequently Asked Questions ................................................... 23
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
1 Introduction
Since the introduction of Version 4 of the Clearswift SECURE Gateways, the
products run on a Red Hat Enterprise Linux 64 bit Platform. Having a standard
underlying Linux distribution opens a wide range of options and flexibility to fulfil
specific clients’ requirements.
This guide explains what is required and how to monitor the Gateways from
Microsoft System Center Operations Manager (SCOM).
The configuration described in this guide has been validated on the below versions:
SECURE Email Gateway – Version 4.0.0
2 Scope
This guide describes how to configure the required software on the Clearswift
Gateway side and its integration with SCOM. It is not intended to provide an
installation or configuration guide for SCOM.
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
3 Configuration and Setup
3.1 Overview
Microsoft System Center Operations Manager (SCOM) provides infrastructure
monitoring that is flexible and offers comprehensive monitoring for datacenters
and cloud, both private and public. For more information on SCOM, visit
http://technet.microsoft.com/library/hh205987.aspx
SCOM monitoring is based on deploying agents in systems to monitor, which collect
statstics and send it back to a SCOM server. There are specific Management Packs
for different operating systems, but new ones can be created to monitor custom
applications or non standard stats.
In the case of the Gateways, a Red Hat 6 agent is required. This guide does not
provide a guide on how to create a custom management pack for the Gateways.
3.2 Installation
In order to deploy the agents and monitor the platform, the following steps need
to be taken:
Create a Linux user account for the monitoring service
Sudoers file configuration
iptables configuration (Linux firewall)
Allowing SSH access
Verify DNS – forward and reverse lookup
Import Management Packs
Create a monitoring resource pool
Runas accounts and profiles
Configure Gateways to monitor
These steps are detailed in the next sub-sections.
3.2.1 Create a Linux user account for the monitoring service
A new dedicated account needs to be created in the Gateways for monitoring
purposes. In order to create the account, log in the Gateway through the command
line console or SSH, open a terminal session, and as root run:
# useradd opsmgrsvc
# passwd opsmgrsvc
Changing password for user opsmgrsvc.
New password:
Retype new password:
passwd: all authentication tokens updated successfully.
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
3.2.2 Sudoers file configuration
The newly created user must be able to run commands as root, so an entry in the
sudoers file must be created. Editing the sudoers file can be done by running the
“visudo” command. Then, at the bottom of the file, the below must be added:
Defaults:opsmgrsvc !requiretty
opsmgrsvc ALL=(root) NOPASSWD: ALL
Please note that this configuration allow the user to run as root anything without
asking for a password. If a tighter configuration is required, the below
configuration can be used as explained in
http://social.technet.microsoft.com/wiki/contents/articles/7375.configuring-
sudo-elevation-for-unix-and-linux-monitoring-with-system-center-2012-operations-
manager.aspx:
#-----------------------------------------------------------------------------------
#User configuration for Operations Manager agent – for a user with the name: opsmgrsvc
#General requirements
Defaults:opsmgrsvc !requiretty
#Agent maintenance (discovery, install, uninstall, upgrade, restart, cert signing)
opsmgrsvc ALL=(root) NOPASSWD: /bin/sh -c cp /tmp/scx-opsmgrsvc/scx.pem
/etc/opt/microsoft/scx/ssl/scx.pem; rm -rf /tmp/scx-opsmgrsvc;
/opt/microsoft/scx/bin/tools/scxadmin -restart
opsmgrsvc ALL=(root) NOPASSWD: /bin/sh -c sh /tmp/scx-opsmgrsvc/GetOSVersion.sh; EC=$?; rm -rf
/tmp/scx-opsmgrsvc; exit $EC
opsmgrsvc ALL=(root) NOPASSWD: /bin/sh -c cat /etc/opt/microsoft/scx/ssl/scx.pem
opsmgrsvc ALL=(root) NOPASSWD: /bin/sh -c rpm -e scx
opsmgrsvc ALL=(root) NOPASSWD: /bin/sh -c /bin/rpm -F --force /tmp/scx-opsmgrsvc/scx-1.[0-
9].[0-9]-[0-9][0-9][0-9].rhel.[0-9].x[6-8][4-6].rpm; EC=$?; cd /tmp; rm -rf /tmp/scx-
opsmgrsvc; exit $EC
opsmgrsvc ALL=(root) NOPASSWD: /bin/sh -c /bin/rpm -U --force /tmp/scx-opsmgrsvc/scx-1.[0-
9].[0-9]-[0-9][0-9][0-9].rhel.[0-9].x[6-8][4-6].rpm; EC=$?; cd /tmp; rm -rf /tmp/scx-
opsmgrsvc; exit $EC
#Log file monitoring
opsmgrsvc ALL=(root) NOPASSWD: /opt/microsoft/scx/bin/scxlogfilereader -p
###Examples
#Custom shell command monitoring example – replace <shell command> with the correct command
string
#opsmgrsvc ALL=(root) NOPASSWD: /bin/bash -c <shell command>
#Daemon diagnostic and restart recovery tasks example (using cron)
#opsmgrsvc ALL=(root) NOPASSWD: /bin/sh -c ps -ef | grep cron | grep -v grep
#opsmgrsvc ALL=(root) NOPASSWD: /usr/sbin/cron &
#End user configuration for Operations Manager agent
#-----------------------------------------------------------------------------------
3.2.3 Iptables configuration(Linux firewall)
Even though Operations Manager uses SSH to transfer information and to execute
scripts, it first requires connecting to the agent via port 1270.
The firewall settings in the Gateways will prevent this from happening unless the
firewall is configured to allow this access. It can be done by creating or editing the
file /opt/cs-gateway/custom/custom.rules and adding the below line:
-I INPUT 1 -p tcp -s 192.168.2.116/32 --dport 1270 -m state --state NEW,ESTABLISH -j ACCEPT
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
Policy must be applied through the Web UI for the rule to be configured in the
firewall.
3.2.4 Allowing SSH access
As the Operations Manager sever needs to access the agent through SSH, it is
needed to allow access to it through the Gateway Web UI by accessing System-
>System Settings->SSH Access and adding the Operations Manager’s IP address to
the list of SSH allowed addresses:
Figure 1: SSH access settings
The policy must be applied for changes to take effect.
3.2.5 Verify DNS – forward and reverse lookup
The Operations Manager will not allow the definition of a server to be monitored if
its name o IP cannot be resolved. So the DNS configuration in the Operations
Manager server must ensure that both forward and reverse DNS lookups will resolve
the Gateway name and IP to be monitored:
Figure 2: Adding a DNS record
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
3.2.6 Import Management Packs
The core Unix/Linux libraries are already imported after the installation of
Operations Manager 2012, but not the detailed Management Packs for each OS
version.
These packs are available on the installation media, in the \ManagementPacks
directory.
Figure 3: Available management packs
For the v4 Gateways, the following Management Packs are required:
Microsoft.ACS.Linux.RHEL6.mp
Microsoft.ACS.Unix.Library.mp
Microsoft.Linux.Library.mp
Microsoft.Linux.RedHat.Library.mp
Microsoft.Linux.RHEL6.mpb
These MP’s can be imported through the Operations Manager UI browsing to
Administration->Management Packs and selecting the Import Management Packs
action on the right pane:
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
Figure 4: Importing management packs
After adding the above list from disk, the install process can start. If there are
unmet dependencies, the import process will show them and the appropriate
management packs will need to be added.
Figure 5: Management packs installation
Now these packages are made available to deploy on the managed servers.
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
3.2.7 Create a monitoring resource pool
A resource pool is a group of Operations Manager monitoring servers dedicated to
monitoring a specific type of servers, e.g. Networking, UNIX/Linux,…
It is common practice to create a group for each type of platform to monitor. This
is done to be able to escalate properly and to have dedicated monitoring resources
for servers that might generate a high number of events.
This step is not mandatory and it is possible that a resource pool will already exist
in a production environment to monitor such servers. In any case, the steps are
described below.
Resource pools can be created through the Operations Manager console under
Administration -> Resource Pools.
Figure 6: Create a new resource pool
The New Resource Pool Wizard window opens, where a name can be defined:
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
Figure 7: New resource group wizard
Assign the selected monitoring servers to the resource group and complete the
wizard.
Figure 8: Resource pool definition
The resource pool definition is complete.
3.2.8 Configure Runas accounts and profiles
Computers and devices could now be added to the system to be monitored.
However, unless the monitoring accounts are configured in the system, Operations
Manager will only report whether the system is running or not.
By assigning accounts to monitoring profiles, Operations Manager will be able to
monitor the status of the different components of the system.
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
Two types of accounts will be configured: a standard monitoring one and a
privileged account.
3.2.8.1 Monitoring Account
A new account can be created in Administration -> Run As Configuration ->
UNIX/Linux Accounts by selecting Create Run As Account in the right pane.
Figure 9: Create a Run As account
As this is a non-privileged account, the opsmgrsvc details will be configured, and
Do not use elevation with this account will be selected.
Figure 10: Account credentials
The next step in the configuration asks for the distribution security options. For
this account, More secure should be selected.
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
Figure 11: Account distribution security
The next account to configure is the elevated monitoring account.
3.2.8.2 Monitoring elevated monitoring account
This account can be created in exactly the same way as the previous one, but
selecting different account credential options. As the same user can be configured
in both types of accounts, the display name must be configured so that it is
possible to differentiate both types. In this example, the account will be named
opsmgrsvc – privileged.
Figure 12: Privileged account creation
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
In the account credentials details, the option Elevate this account using sudo for
privileged access must be selected.
Figure 13: Account credential details
As done previously, the distribution security option should be set to More secure.
3.2.8.3 Associate accounts with profiles
The newly created accounts have to be associated with monitoring profiles to be
used to monitor the Gateways. There are two profiles to associate the accounts
with:
UNIX/Linux Action Account: The opsmgrsvc account will be associated to this profile
UNIX/Linux Privileged Account: The opsmgrsvc - privileged account will be associated to this profile
Both are associated exactly in the same way and the only difference is the profile
that is selected to do the association.
Under Administration -> Run As Configuration -> Profiles, double click on the
appropriate profile.
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
Figure 14: Associating accounts to profiles
New accounts can then be added to the profile. The appropriate account must be
selected based on the profile. The scope can be left to All targeted objects, as
afterwards the account will be associated with the resource group created before.
Figure 15: Select account to associate
Once saved, the wizard allows clicking on the account name to select where to use
the configured account. This is described in the final wizard page, as the account
has been created as More secure, which means that it should be defined manually
where to use those credentials.
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
Figure 16: Associate account wizard final page
After clicking on the account name, it is possible to select the resource group to
which this account must be distributed. In this case, the Clearswift SECURE
Gateways resource group will be used.
Figure 17: Assign distribution lists
This process must be completed for both profiles: UNIX/Linux Action Account with
the opsmgrsvc account, and UNIX/Linux Privileged Account with the opsmgrsvc-
privileged account.
3.2.9 Configure Gateways to monitor
The Clearswift Gateways can now be configured in Operations Manager to be
monitored. Computers and devices can be added in the Operations Manager
interface in Administration -> Device Management:
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
Figure 18: Adding the Gateways to Operations Manager
The Computer and Device Management Wizard opens. After selecting UNIX/Linux
computers as the device time, the appropriate criteria to discover the gateways
will need to be added. The Clearswift SECURE Gateways Resource Pool should be
selected to have the proper accounts utilized to monitor the Gateways:
Figure 19: Discovery criteria configuration
Either by IP address or hostname, define in the discovery scope as many entries as
needed. Credentials will need to be configured using user name and password.
Following the configuration previously done, the opsmgrsvc user will be configured
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
and stated that it has no privilege access, so that it uses sudo escalation to achieve
it:
Figure 20: Discovery criteria definition
Once the criteria are saved and the discovery process run, the configured gateways
must be available for selection:
Figure 21: Discovered gateways
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
After selecting them and clicking on Manage, Operations Manager will connect to
the Gateways through SSH to install the management agent:
Figure 22: Management pack deployment
Once this step is completed, Operations Manager starts monitoring the Gateways.
4 Monitoring the Gateways
The installed management packs can review the internal status of Red Hat
systems. A fast view of the status can be found under Monitoring->UNIX/Linux
Computers in the Operations Manager interface:
Figure 23: Monitoring the Gateways
In case of finding that a gateway is in a critical status, a detailed view can be used
to find out which parts of the system are failing.
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
Figure 24: Monitored Gateway in a Critical status
Right clicking on the failed server allows having different views, which will allow
doing a root cause analysis.
Figure 25: Root cause analysis
The Diagram View allows pinpointing the area in which the problem has been
found:
Figure 26: Diagram view
However, this view does not allow taking actions on the problems found. The Alert
view, though, allows managing the alerts found in the system.
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
Figure 27: Alert view of a Clearswift Gateway
A number of alerts are triggered after the monitoring starts. The management
packs for Red Hat monitor for a range of services that assume must always be
running, including Syslog, the ACPI daemon, NFS and all the NFS related services.
As the Clearswift Gateways make a customized installation of Red Hat, some of the
Operations Manager default monitored services are not running in the Gateways.
These monitors can be disabled for the gateways by right clicking on the alert row
and selecting Overrides -> Disable the Monitor -> For the object:
Figure 28: Disabling unnecessary monitors
This configuration could be saved in the Red Hat management pack, but it should
instead be saved in a new management pack:
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
Figure 29: Override monitoring in a new management pack
After overriding the monitoring on a new management pack, the system reports
back that the Gateways are in a correct status:
Figure 30: New Gateways status
5 Troubleshooting
The configuration process can fail for a number of reasons. The most common ones
and how to troubleshoot them are shown in this section.
5.1 No SSH access
The Operations Manager servers that monitor the Gateways must have access to
them through SSH. So access must be allowed through the Gateways’ UI. If access
has not been granted, it will be reported when trying to discover the Gateways.
5.2 Incorrect account privileges
The account configured to be used by the Operations Manager server after logging
through SSH must be able to sudo without being asked for a password. If the
configuration hasn’t been set correctly, monitoring will fail.
Monitoring Clearswift Gateways with
SCOM
Clearswift Public
5.3 Incorrect management pack imported
If the Red Hat 6 management pack and all its dependencies have not been
installed, the agent will not be installed. The management packs downloaded from
the catalogue are not always the most appropriate. It is recommended to install
the ones provided on the installation media and upgrade them if necessary with
the ones on the online catalogue.
5.4 General troubleshooting
The Gateways will log access to SSH in the /var/log/cs-gateway/auth-YYYY-MM-
DD.log file. It will also show whenever a sudo command is executed and the
command it is used with. This can be used to validate that the monitoring agent is
being correctly executed.
Nov 28 19:25:20 cs-gw-23358 sudo: opsmgrsvc : TTY=unknown ; PWD=/var/opt/microsoft/scx/run ;
USER=root ; COMMAND=/opt/microsoft/scx/bin/scxlogfilereader -p
Nov 28 19:30:20 cs-gw-23358 sudo: opsmgrsvc : TTY=unknown ; PWD=/var/opt/microsoft/scx/run ;
USER=root ; COMMAND=/opt/microsoft/scx/bin/scxlogfilereader -p
Nov 28 19:35:20 cs-gw-23358 sudo: opsmgrsvc : TTY=unknown ; PWD=/var/opt/microsoft/scx/run ;
USER=root ; COMMAND=/opt/microsoft/scx/bin/scxlogfilereader -p
6 FAQ – Frequently Asked Questions
Q: Is there a Management Pack available to monitor the internal status of the
Clearswift Gateways?
A: Clearswift does not provide a Management Pack to monitor the status of
Clearswift Gateways. However, administrators can create a new one based on
the standard templates provided by SCOM to monitor the status of the
gateway’s processes.