molbloc-L® & molbloc-S® GAS CALIBRATION AVAILABILITY MATRIX
The following charts provide information on the availability of molbloc gas calibrations at DHI for gases supported by molbox, molbox1, and molbox-RFM. The statuses of molbloc references are represented in five categories. The categories are defined as:
Y = Yes, Calibration available. P = Calibration Planned but not yet available. N = No calibration planned for yet, not currently available. F = (molbloc-S only) Gas to be added to Future revision of molbox. X = molbox selection only, no calibration support planned (too hazardous).
molbloc-L® SIZE / RANGE
GASES 1E1 10
sccm
5E1 50
sccm
1E2 100
sccm
2E2 200
sccm
5E2 500
sccm
1E3 1
slm
5E3 5
slm
1E4 10 slm
3E4 30 slm
1E5 100slm
Nitrogen N2 Y Y Y Y Y Y Y Y Y Y Argon Ar N Y Y Y Y Y Y Y Y Y Helium He N N Y Y Y Y Y Y Y Y Sulfur Hexafluoride SF6 Y Y Y Y Y Y Y Y Y N Xenon Xe N N N N N N N N N N
Butane C4H10 N N N N N N N N N N Ethane C2H6 N N N N N N N N N N Ethylene C2H4 N N N N N N N N N N Hydrogen H2 N Y Y Y Y Y Y Y Y Y Methane CH4 N P P P P P P P P P Propane C3H8 N N N N P P P P P N Oxygen O2 X X X X X X X X X X
Carbon Tetrafluoride CF4 N P P P P P P P P N Hexafluoroethane C2F6 N N N N N N N N N N Octofluorocyclobutane C4F8 N N N N N N N N N N Trifluoromethane CHF3 N N N N N N N N N N
Air Air Y Y Y Y Y Y Y Y Y Y Carbon Dioxide CO2 N Y Y Y Y Y Y Y Y P Carbon Monoxide CO X X X X X X X X X X Nitrous Oxide N2O N P P P P P P P P N
February 12, 1998/MGB Revision Date 2009 January 12
Primary Pressure Standards
Pressure Controller/ Calibrators
Reference Pressure Monitors
Gas Flow Standards
Calibration Software
Calibration and Repair Services
Training Courses
Affiliates Worldwide
Y = Yes, Calibration available. P = Calibration Planned but not yet available
NOTE: Y & P on molbloc-S includes nominal full-scale flow @ 500 kPa, or if the calibration support is limited the maximum supported flow with the corresponding pressure in kPa absolute given in brackets [].
N = No calibration planned for yet, not currently available. F = Gas to be added to Future revision of molbox (molbloc-S only) X = molbox selection only, no calibration support planned (too hazardous)
molbloc-S® SIZE / RANGE
GASES 1E1 2E1 5E1 1E2 2E2 5E2 1E3 2E3 5E3 1E4
Nitrogen N2 Y 5
Y 10
Y 25
Y 50
Y 100
Y 250
Y 500
Y 1000
Y 2500
Y 2800 [280]
Argon Ar Y 4
Y 8
Y 21
Y 42
Y 84
Y 210
Y 420
Y 840
Y 1600 [385]
Y 1600 [192]
Helium He P 13
P 26
P 66
P 130
P 260
P 330
[250] N N N N
Sulfur Hexafluoride SF6 P 2
P 4
P 11
P 22
P 44
P 110
P 110
[250] N N N
Xenon XE F, N F, N F, N F, N F, N F, N F, N F, N F, N F, N
Butane C4H10 F, X F, X F, X F, X F, X F, X F, X F, X F, X F, X
Ethane C2H6 F, N F, N F, N F, N F, N F, N F, N F, N F, N F, N
Ethylene C2H4 F, N F, N F, N F, N F, N F, N F, N F, N F, N F, N
Hydrogen H2 Y 18.5
Y 37
Y 93
Y 187
Y 373
Y 750
[400]
Y 750
[200] N N N
Methane CH4 P 6.5
P 13
P 33
P 66
P 132
P 330
P 330
[250] N N N
Propane C3H8 F, N F, N F, N F, N F, N F, N F, N F, N F, N F, N
Oxygen O2 F, X F, X F, X F, X F, X F, X F, X F, X F, X F, X
Carbon Tetrafluoride CF4 F, N F, N F, N F, N F, N F, N F, N F, N F, N F, N
Hexafluoroethane C2F6 F, N F, N F, N F, N F, N F, N F, N F, N F, N F, N
Octofluorocyclobutane C4F8 F, N F, N F, N F, N F, N F, N F, N F, N F, N F, N
Trifluoromethane CHF3 F, N F, N F, N F, N F, N F, N F, N F, N F, N F, N
Air Air Y 5
Y 10
Y 25
Y 50
Y 100
Y 250
Y 500
Y 1000
Y 2500
Y 2800 [280]
Carbon Dioxide CO2 P 4
P 8
P 20
P 40
P 80
P 200
P 318
[400]
P 318
[200] N N
Carbon Monoxide CO F, X F, X F, X F, X F, X F, X F, X F, X F, X F, X
Nitrous Oxide N2O P 4
P 8
P 20
P 30 N N N N N N