module 12 frosch
DESCRIPTION
aci 14TRANSCRIPT
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 1
WWW.CONCRETE.ORG/ACI318 1
Chapters 21, 22, 24, 25 – Toolbox Chapters
ACI 318-14:Reorganized for Design
WWW.CONCRETE.ORG/ACI318 2
Toolbox Chapters
• Ch. 21 – Strength Reduction Factors• Ch. 22 – Sectional Strength• Ch. 24 – Serviceability Requirements• Ch. 25 – Reinforcement Details
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 2
WWW.CONCRETE.ORG/ACI318 3
Toolbox Chapters
• Referenced mainly by member chapters in part or in whole
• Requirements organized by topic• Contain requirements that would otherwise
be repeated in several chapters• Allows simpler modification in future editions
WWW.CONCRETE.ORG/ACI318 4
Ch. 21 – Strength Reduction Factors
• Ch. 21 is a simple reference chapter• Contains all reduction factors in tabular
form• Section 21.2 referenced by member
chapters
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 3
WWW.CONCRETE.ORG/ACI318 5
Ch. 21 – Strength Reduction Factors
• Lists strength reduction factor requirements based on:– action or structural element– axial load, moment, and combined, – ends of prestressed members
• Special requirements for φ in structures resisting earthquake effects
WWW.CONCRETE.ORG/ACI318 6
Ch. 21 – φ for pretensioned members *
Clarified φ for sections near the end of pretensioned members *
ACI 318-11, 12.9.3: Where bonding of a strand does not extend to end of member, and design includes tension at service load in precompressedtensile zone as permitted by 18.3.3, ld specified in 12.9.1 shall be doubled.
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 4
WWW.CONCRETE.ORG/ACI318 7
Ch. 21 – φ for pretensioned members *
Clarified φ for sections near the end of pretensioned members *
WWW.CONCRETE.ORG/ACI318 8
Ch. 22 – Sectional Strength
• Referenced in member chapters by section• Used as a reference for strength calculations• Not intended to be read from beginning to
end
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 5
WWW.CONCRETE.ORG/ACI318 9
Ch. 22 – Sectional Strength• Chapter subheadings
– 22.1 Scope– 22.2 Design assumptions for moment and axial str.– 22.3 Flexural strength– 22.4 Axial strength or combined flexural and axial str.– 22.5 One-way shear strength– 22.6 Two-way shear strength– 22.7 Torsional strength– 22.8 Bearing– 22.9 Shear friction
WWW.CONCRETE.ORG/ACI318 10
22.2 - Design assumptions for moment and axial design
• Maximum strain at extreme concrete fiber, εc = 0.003
• Neglect concrete tensile strength
• “Plane sections remain plane”
εt
εc = 0.003
c C = 0.85f’cba
T=Asfy
neutral axisa
d
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 6
WWW.CONCRETE.ORG/ACI318 11
Flexural, axial, or combined strength
• 22.3 - Flexure– Mn based on assumptions in 22.2
• 22.4 - Axial or Combined Axial & Flexural– Mn and Pn based on assumptions in 22.2– Pn,max = (Factor) (Po)
WWW.CONCRETE.ORG/ACI318 12
22.4.2.3 - Axial strength for prestressed member
Calculate Po (previously undefined) *
= . − − + − − .(Eq. 22.4.2.3)
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 7
WWW.CONCRETE.ORG/ACI318 13
22.4.3.1 – Maximum axial tensile strength *
Added equation 22.4.3.1 for the maximum nominal axial tensile strength of any member *
Where:• fse = effective stress in prestressing reinforcement, after allowance for all prestress losses, psi• Δfp = increase in stress in prestressingreinforcement due to factored loads, psi
, = + + ∆ (22.4.3.1)
WWW.CONCRETE.ORG/ACI318 14
Shear strengths
• 22.5 - One-way shear– Vn = Vc + Vs
• 22.6 - Two-way shear• vn = vc + vs
• 22.9 - Shear friction– Vn = μ Avf fy
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 8
WWW.CONCRETE.ORG/ACI318 15
22.9 - Shear-Friction Behavior *
T= Avf fy
Shear Plane(Assumed Crack)
Shear FrictionReinforcement
Vn = Cμ = Tμ = Avf fyμ
Vn
Vn Slip
Vn =Cμ
Note: C=T
Vn
Gap
C
WWW.CONCRETE.ORG/ACI318 16
Ch. 22 – Shear friction *
Clarification that shear friction does not apply when reinforcement is in compression *
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 9
WWW.CONCRETE.ORG/ACI318 17
Torsion and bearing strengths
• 22.7 - Torsion– Torsion threshold – can
neglect torsional effect
– Cracking torsion – can design for cracking torsion if torsion can be redistributed
• 22.8 - Bearing– Bn = 0.85 A1 f’c
WWW.CONCRETE.ORG/ACI318 18
Ch. 24 – Serviceability Requirements
• Referenced in member chapters by section• Not intended to be read from beginning to
end• Used as a reference for serviceability
calculations
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 10
WWW.CONCRETE.ORG/ACI318 19
Ch. 24 – Serviceability Requirements
• Chapter subheadings – 24.1 Scope– 24.2 Deflections due to service-level gravity loads– 24.3 Distribution of flexural reinforcement in one-
way slabs and beams– 24.4 Shrinkage and temperature reinforcement– 24.5 Permissible stresses in prestressed concrete
flexural members
WWW.CONCRETE.ORG/ACI318 20
24.2 - Deflections due to service-level gravity loads
• Allowable deflection limits• Time dependent deflections• Effective moments of inertia
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 11
WWW.CONCRETE.ORG/ACI318 21
Ch. 24 – Change in permissible deflection *
• Table 24.2.2• Removed exception for exceeding allowable
deflection after attachment of nonstructural element when camber is provided
• Applies to roof or floor construction supporting or attached to nonstructural elements not likely to be damaged by large deflections
[4]Limit shall not be greater than tolerance provided for nonstructural elements. Limit may be exceeded if camber is provided so that total deflection minus camber does not exceed limit. *
WWW.CONCRETE.ORG/ACI318 22
24.3 - Distribution of flexural reinforcement– Maximum spacing for crack control– Flanges of T-beams
24.4 - Shrinkage and temperature– Minimum reinforcement– Maximum spacing is the lesser of 5h or 18 in.
24.5 – Stresses in prestressed members
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 12
WWW.CONCRETE.ORG/ACI318 23
Ch. 25 – Reinforcement Details
• Referenced in member chapters by section• Not intended to be read from beginning to
end
WWW.CONCRETE.ORG/ACI318 24
Ch. 25 – Reinforcement Details
• Chapter subheadings – 25.1 Scope– 25.2 Minimum spacing of reinforcement– 25.3 Standard hooks, seismic hooks, crossties, and
minimum inside bend diameters– 25.4 Development of reinforcement– 25.5 Splices– 25.6 Bundled reinforcement– 25.7 Transverse reinforcement– 25.8 Post-tensioning anchorages and couplers– 25.9 Anchorage zones for post-tensioned tendons
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 13
WWW.CONCRETE.ORG/ACI318 25
25.2 - Minimum spacing of reinforcement
• Nonprestressed bars in a horizontal layer– 1 in.– 1 bar diameter– (4/3) nominal maximum aggregate size
• Longitudinal reinforcement in columns, pedestals, struts, and boundary elements– 1.5 in.– 1.5 bar diameters– (4/3) nominal maximum aggregate size
WWW.CONCRETE.ORG/ACI318 26
25.3 - Standard hooks, seismic hooks, crossties, and minimum inside bend diameters
*
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 14
WWW.CONCRETE.ORG/ACI318 27
25.4 – Development of reinforcement
• Tension development length – Straight bar – Hooks– Headed bars– Mechanical anchors– Welded wire reinforcement– Strand
• Compression development of deformed bars and wires
• Reduction for excess reinforcement
WWW.CONCRETE.ORG/ACI318 28
Development length table *
ACI 318-14, R25.4.2.4: Should be considered for inclined reinforcement
ACI 318-14, Table 25.4.2.4: Changed from “Top Bar” to “Casting Position” *
*
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 15
WWW.CONCRETE.ORG/ACI318 29
Ch. 25 – Commentary – closely spaced headed bars *
• ACI 318-14, R25.4.4.2: Where closely spaced headed bars are used, the potential for concrete breakout failure exists. …concrete breakout failure can be precluded by providing anchorage length equal to or greater than d/1.5 …or by providing reinforcement in the form of hoops and ties…
WWW.CONCRETE.ORG/ACI318 30
25.5 Splices
• Lap splices– Based on development lengths– Excess reinforcement reduction for development
length not permitted– Contact and noncontact– Bundled bars– Tension and compression
• End-bearing, mechanical, and welded splices
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 16
WWW.CONCRETE.ORG/ACI318 31
Yield strength of mechanical and welded splices *
• Removed “full” splice language *• Eliminated mechanical and welded splices not
meeting 125% of fy for No. 5 bars and smaller *
ACI 318-11 ACI 318-14
Removed provision
WWW.CONCRETE.ORG/ACI318 32
25.6 – Bundled reinforcement
• Bundled bars– Number– Size– Stagger– Development– Splices
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 17
WWW.CONCRETE.ORG/ACI318 33
25.7 – Transverse reinforcement
• Configuration and anchorage • Stirrups• Ties
– Rectilinear– Circular
• Spirals• Hoops
WWW.CONCRETE.ORG/ACI318 34
25.7.2.4.1 — Anchorage of Circular Tiesa) Ends shall overlap by at least 6 in.b) Ends shall terminate with std
hooks …c) Overlaps at ends of adjacent
circular ties shall be staggered around the perimeter enclosing the longitudinal bars.
New in 2011
American Concrete Institute © 2015. All rights reserved. No part of this publication may be reproduced, copied, distributed, or transmitted in any form. 18
WWW.CONCRETE.ORG/ACI318 35
Fig. R25.7.2.3b — Continuous Ties *New in 2014
Continuously wound bars or wires can be considered as ties, provided their pitch and area are at least equivalent to the area and spacing of separate ties. *
WWW.CONCRETE.ORG/ACI318 36
Post-tensioning anchorage
• 25.8 - Post-tensioning anchorages and couplers
• 25.9 - Anchorage zones for post-tensioned tendons