Page 1: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

ISSUE 6

Model SH0586 & SH0582 Small Automatic Panel Sprayer

Single gun Operators Manual

Page 2: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

1

1.0 Introduction

The TQC Sheen automatic panel sprayers have been designed to remove inconsistencies in the application of wet sprayed coating materials when applied by experienced operators using a hand held gun.

The machines are equipped with a range of adjustments to enable the operator to determine the optimum settings for consistency in the application of a wide range of liquid coating materials. Subsequent sample batches can be applied using the same settings.

Consistency in coating application is absolutely essential for subsequent evaluation of visual properties including colour, gloss, opacity and general appearance, also for the physical properties including thickness, sagging, levelling and adhesion.

Evaluation of these parameters is particularly important when applying high performance coatings such as metallic, pearlescent paints and specialist effect coatings.

The elimination of variabilities at the application stage enables any discrepancies in the applied coatings to be attributable to differences in formulation or processing before the application of the coating material.

Page 3: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

2

2.0 Panel Sprayer Features • Easy to operate controls.

• All functions and movements are operated by compressed air.

• Adjustable gun to panel distance, gun travel speed and spray pressure.

• Adjustable panel lift 40 & 50mm settings for SH0586, this assists overspray of the previous pass of

the spray gun.

• SH0582 model benefits customer specified panel lift increments, from 10 to 500mm. (smaller

increments produces greater overspray of previous pass of the spray gun.

(lift increments to be specified at the time of ordering)

• Flash off timer, to enable optimum setting of rest period between each coating.

• Framework and panels are constructed from stainless steel, making for easy cleaning.

• Magnetic Panel holders. (Vacuum holders for non-metallic panels if required, available at the time or

ordering)

• Suitable for use in all spray booths.

• Lockable castors are fitted to aid easy manoeuvrability.

• Emergency and Reset button

• Easy access to internal parts/mechanism for simplified service and cleaning.

• Fitted with integral air filters & regulators

• Compressed air connection by 12mm diameter hose line, speed fit connectors or ½”BSP

connection.

Page 4: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

3

3.0 Contents

Title & image of machine Front Cover 1.0 Introduction 1 2.0 Panel Sprayer Features 2 3.0 Contents 3 4.0 Packing Information 6 5.0 Safety Feature 6 6.0 Guide to Safety 6 7.0 Installation 7 7.1 Operating the Panel Sprayer 7

7.2 Operating Checks 7

7.3 Cleaning 8

8.0 Control Panel Operation 9 8.1 Panel Holder 9

8.2 Brush Seals 9

8.3 Top Panel 9

8.4 Control Panel 9

8.5 Cover Panel 9

8.6 Air input connector 9

8.7 Castors 9

8.8 Handles 9

8.9 Air Supply 9

9.0 Control Panel Operation 10 9.1 Manual/Off/Auto-switch 10

9.2 Manual Spray 10

9.3 Spray Pressure Gauge 10

9.4 Spray Pressure Regulator 11

9.5 Lift Selector 11

9.6 Number of Coats Counter 11

9.7 Flash-off Timers 11

9.8 Traverse Speed Control 11

9.9 Manual Traverse 11

9.10 Start Button 11

9.11 Raise/Reset Button 12

9.12 Emergency Stop 12

Page 5: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

4

3.0 Contents

10.0 Installation 12

10.1 Main Air Supply 12

10.2 Setting Main Air Pressure 12

11.0 Panel holder Preparation 13 11.1 Test Panels 13

12.0 Spray Gun Preparation 13 12.1 Gun Post Assembly 13

12.2 Airline to Spray Guns 13

13.0 Operating Instructions 14 13.1 Instructions 14

13.2 Air Supply 14

13.3 Isolator Valve 14

13.4 Control Panel 14

13.5 Spray Gun Setting 14

13.6 Travers Speed 14

13.7 Panel Lift 14

13.8 Coats Counter 14

13.9 Flash-off Timer 15

13.10 Test Panels 15

13.11 Start Button 15

14.0 Panel Sprayer Standard Specification 16 15.0 Optional Equipment 16 16.0 Product Compliances 16

16.1 Functions Compliance 16

16.2 Product Legislation 16

16.3 Safety Compliances 16

17.0 Associated Products 17 17.1 Test Panels 17

17.2 Wet Film Thickness Gauges 17

17.3 Further information on accessories 17

Page 6: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

5

3.0 Contents

18.0 Maintenance 18

18.1 Safety 18

18.2 Compressed Air Filter 18

18.3 Traverse Assembly 18

18.4 General Inspection 19

18.5 Fault Finding 19

18.6 Pre-Fault Finding Checks 19

18.7 Panel Sprayer Fault Finding 19

18.8 Traverse Faults 19

18.9 Machine stops in Mid Cycle 20

19.0 Service & Contact Information 21 19.1 Training 21

19.2 Product Service 21

19.3 Fault Reporting 21

19.4 Service Contact & Address 21

Page 7: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

6

4.0 Packing information The Sprayer is supplied complete with Panel Holder, cable for connection to electrical earth, (for static dissipation) product manual and any accessory ordered at the time of manufacture. 4.1 Packing List Check that all items on the packlist have been supplied, inspect all items to ensure that there is no damage. Inform TQC Sheen, (phone: +31 10 7900 100, email: [email protected] should there be any discrepancies).

5.0 Safety Features Air Supply Shut-Off Valve – External air supply to the Sprayer Machine.

Emergency Stop Button – When operated machine stops instantly. Reset has to be initiated to restart.

Reset Speed Control of Traverse Cylinder- This is an independent speed control separate from the panel

restrictor, providing slow speed (preset) when reset is initiated.

Rear Guard Rail – Preventing obstruction to panel lift assembly.

Warning Labels – Clearly highlighting the area of the traverse cylinder that must not be obstructed or

approached during cycle.

Product Disposal

6.0 Guide to Safety The automatic panel sprayer has been designed and constructed to provide operator with optimum safety

and ease of operation.

The following should be read and understood and by operating and maintenance personnel prior to operating

the automatic panel sprayer.

Page 8: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

7

7.0 Installation 1. When moving the panel sprayer it is advisable that two people carry out the operation and where

possible to move the sprayer in a longitudinal manner to retain maximum stability.

2. Main air supply must not exceed 10 Bar (150psi) volume capacity able to supply a consumption of

approximately 35 scfm.

3. Connecting the air supply to the sprayer with 12mm diameter tubing hose line, speed fit connectors or

½” BSP connection.

4. Check that the siting of the Sprayer within spray booth can accommodate panel lift system to its

maximum height (1.8 metres).

5. Ensure front castor brakes are engaged prior to operation.

6. If protective covering over the sprayer panels is to be used ensure that safety warning labels are not

hidden.

7. An earth-wire connection point is provided for potential static discharge to a main electrical earthing

point.

8. Check all switches are in the ‘OFF’ condition, turn on main air supply and check for air leaks. It is

important that any leak is dealt with prior to using sprayer.

9. General Guide to installation see section

10. Approximate weight of the SH0586 & SH00682 is 85kg

7.1 Operating the panel sprayer 1. Check that all panels are in position and secure.

2. Ensure that brush strips are not obstructed.

3. Check that spray guns are secure, and that only recommended cups are being used.

4. Important: during sprayer cycle keep clear of spray gun post and under no circumstance place hands

near the brush strip.

5. Check that cycle is complete before removal of the test panels. Dwell timers should be showing the

pre-set status and coats counter displaying equal pre-set and current value.

6. In the event of mechanical or cyclic problems the Emergency Stop Button should be operated.

7.2 Operating Checks 1. Check condition of all switches, in particular the Emergency Stop Button. Broken actuators must be

replaced.

2. Do not leave air supply on if working inside cabinet.

3. If leaving machine during maintenance work ensure main air supply is disconnected.

4. Service work to cylinders should be carried out by trained personnel only.

Page 9: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

8

7.3 Cleaning 1. It is advisable to turn air supply off prior to any general cleaning.

2. Ensure all instruments and labels are easily readable at all times.

3. If re-siting the sprayer, disconnect the air supply first.

NOTE: Any modification to the supply specification of the sprayer will invalidate warranty and safety aspects.

Page 10: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

9

8.0 Control Panel Operation

8.1 Panel Holder An anodised aluminium frame fitted with magnets to retain steel test sample panels. The holder is easily removed for cleaning by loosening the socket cap screw located at the base and pulling the holder upwards from the support bar. 8.2 Brush Seals These seals protect the gun traversing cylinder, panel lift cylinder and the components within the sprayer from accidental material spillage and over spray. 8.3 Top Panel This panel is manufactured from stainless steel to facilitate cleaning. A raised lip around the base of the panel holder and the gun post slot serves to prevent material accidentally entering the sprayer. 8.4 Control Panel Stainless steel with all controls and indicator identifications chemically etched. 8.5 Cover Panel All made of stainless steel and fitted with quick release fasteners to allow easy access for service and maintenance.

8.6 Air Input Connector A ½” BSP bulkhead connector is located on the lower right hand side of machine. In addition, a ½” BSP X 12mm straight Speedfit coupling is provided as an option. If a Speedfit coupling is used then the 12mm nylon pipe is connected by simply pushing pipe into connector. To release pipe from Speedfit hold down collet and pull out pipe. 8.7 Castors Four swivelling castors are fitted to the unit, making it very easy to move the sprayer from one location to another. The two front castors are fitted with brakes which must always be locked when the machine is in operation in order to prevent movement. 8.8 Handles A handle is fitted on each side of the sprayer, making it easy to manoeuvre. 8.9 Air Supply The air supply capacity to the Sprayers must be clean, dry and filtered.

Page 11: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

10

9.0 Control Panel Operation

9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started, if it is switched to Off position during the auto cycle, the current spray cycle will complete then come to rest.

Manual provides main air to all manual function switches and when operated it activates emergency stop to prevent start up without reset being actioned. Switching to Auto enables start of cycle.

9.2 Manual Spray Setting this switch to ON causes the gun to spray continuously. This facility is used both for cleaning the gun and for establishing the correct settings.

9.3 Spray Pressure – Gauge This indicates the pressure of mains air being supplied to the spray guns.

Page 12: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

11

9.4 Spray Pressure – Regulator Determines the pressure of the main air supplied to spray guns, and is used in conjunction with gauge 2.3 to prevent accidental alteration the regulator control knob cannot be turned unless it is first pulled out slightly from the control panel. The regulator is then turned clockwise to increase pressure or anti-clockwise to decrease pressure. When pressure is set push knob toward panel to lock.

9.5 Lift Select SH0586 This model provides a choice of 40mm or 50mm lift increments of the panel holder. SH0582 model has the customer specified lift increments (10 to 500mm) adjust accordingly.

NOTE: Maximum lift is 9 raises at 50mm increments, and 11 raises at 40mm increments for the SH0586 model, for SH0582 version, the lift increments is dependent on the customer specification. (range from 10mm to 500mm increments)

NOTE: This should not be changed once the cycle has been started.

9.6 Number of Coats Counter This counter determines the number of times the spray gun repeats a series of passes across the test panels to complete one coat. To set the counter, hold down the white button and push in the ‘1s’ ‘10s’ button repeatedly until the required value is displayed, then release the white button.

9.7 Flash-Off Timer Using this timer provides a delay of up to 10 minutes between the applications of each coat. To set the timer, simply turn the knob to the desired delay time.

If several different flash off times are required during multi-coat spraying, it is possible to change timer setting during spraying sequence.

It is also possible to shorten time delay while timer is operating, even turning dial to zero to start next cycle. However it is not possible to increase time value while timer is operating.

9.8 Traverse Speed Control This control determines the speed at which the gun travels across the face of the test panels. The speed is changed by rotating the dial, clockwise to reduce the speed, anti clockwise to increase speed.

The dial is graduated to enable the operator to make a note of the setting, the graduations do not represent any particular unit of speed.

NOTE: If pressure variations of the incoming mains are experienced it will affect the traverse speed and the controller would require adjustment.

9.9 Manual Traverse This switch provides manual control of traverse cylinder and is of particular use in moving spray gun to a central position, in line with panel holder, for test and setting purposes.

9.10 Start Button When the sprayer has been programmed and spray guns and panels set, press the start button to commence spraying sequence.

Page 13: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

12

9.11 Raise/Reset Button This is a dual purpose switch and is only operable by engaging emergency stop action. The switch is spring centred therefore needs to be held for as long as signal is required.

Reset: Will reset all functions to a start condition. Raise: This allows operator to raise panel holder to a convenient position for loading or unloading panels. To lower panel holder turn switch to reset. 9.12 Emergency Stop Pressing stop button while sprayer is in operation will stop cycle and, spray gun immediately. The sprayer will not function again until reset has been actioned. It is advisable to reset machine, after use of Emergency Stop, within 20 minutes.

10 Installation

10.1 Main Air Supply Allow a suitable period of time for the Sprayer to attain ambient conditions (temperature and humidity)

Clean, dry air, pressure not to exceed 1Mpa (1000kPa) 10 bar (150psi)

Volume capacity approximately 35scfm

Connection main air supply to input bulkhead using 12mm tubing ½” hose line. When using the Speedfit

connector ensure 12mm pipe has a clean square cut and is pushed firmly into collet of fitting.

When using ½” BSP connection make sure that there are no restrictions introduced from any smaller size

additional couplings.

10.2 Earth Wire Connection An earth stud has been provided in order to fit an earthing cable, this is good practice and particularly important in view of the possibility of static electricity.. The stud is located on rear right hand castor mounting plate, accessed through right hand side panel.

Page 14: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

13

11 Panel Holder Preparation Before placing test panels on the panel holder, it is advisable to mask the framework and any magnets (or vacuum holders) that are not in use. This greatly reduces the amount of time and effort required to clean the holder after the machine has been used. The panel holder can be removed from the support bar by loosening the wing nut at the base of the support bar. 11.1 Test Panels Panels must be flat and free from contamination (degreased, no finger prints) to ensure a consistent application of the coating materials. (Also see para 18.0 Associated products) Important Test sample panels should be positioned to the holder in such a way that they are supported at each of the four corners to ensure that the surface is presented flat and perpendicular to the traverse of the spray gun. (The image below refers)

12.0 Spray Gun Preparation

12.1 Gun Post Assembly The SH0586 & SH0582 panel sprayers are designed for single gun use allowing the spray gun to be mounted central to the post. The height of the spray gun is not adjustable, its position provides uniform coverage for maximum panel lift. The horizontal distance between gun and panel is adjustable by releasing locking screw and moving plate left or right. If this is insufficient then plate can be turned through 180°.

12.2 Airlines to Spray Guns Two colour coded lines supply air to the guns. The large green line carries mains air used to propel the paint from the gun. The smaller red line activates the gun trigger, switching the gun on or off as it receives the signal from the machine.

Page 15: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

14

13.0 Operating Instructions

13.1 Instructions Ensure that you have read and understood all sections of this manual, particular attention to be drawn to the control panel operation section, before operating the panel sprayer. 13.2 Air Supply Check that the mains air supply is connected at the machine bulkhead, supply is turned on and no air leaks are present at the connection. Any air leaks must be dealt with before proceeding to operate the sprayer. 13.3 Isolator Valve Remove the right-hand cover panel, check the isolator valve is set to on position and that the machine pressure is set to no more than 7.5 bar (100psi) 13.4 Control Panel Set the control panel “Air On/Off” switch to On position, if the spray gun operates immediately check “manual spray” switch is set to the “Off” position and operate reset. If the panel holder and gun are not in their starting positions (Panel Holder fully in the down position, gun post set to end of the left-hand position of travel) press the emergency stop button then hold reset switch until they return. Ensure nothing is obstructing the traverse/gun post and keep clear of the gun post when operating reset. 13.5 Spray Gun Setting Set the gun distance between the gun and the panel holder. It is possible to position the gun central to the panel holder by first turning the traverse speed control to a low figure, pressure the emergency stop button then operate manual left/right until the gun is in front of the panel holder. If this procedure is followed reset must be actioned prior to start, machine will only start from starting position as previously mentioned. Fill the gun reservoir with the previously prepared sample material (paint, varnish etc.) Using the “Manual Spray switch position check the gun pressure is correct by noting the gauge reading on the control panel, adjust as necessary using the pressure regulator gauge. With the manual spray switch “ON” check spay gun settings for optimum fluid and air delivery to achieve the required atomisation, next switch to “Off”. NOTE. THIS CAN ONLY BE OPERATED FOLLOWING EMERGENCY STOP. 13.6 Traverse Speed Select the required traverse speed 13.7 Panel Lift Select the lift increment switch between 40 & 50 mm on the SH0586 and customer defined settings for the SH0582 model. 13.8 Coats Counter Set the number of coats as required (Note the panel lift has been pre-determined), see above)

Page 16: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

15

13.9 Flash-off Timer Set the Flash-Off Time 0 – 10 minutes. 13.10 Test Panels Place the test panels onto the holder checking first that the holder is masked to prevent overspray and assist in subsequent cleaning. 13.11 Start Button Press the start button to operate the machine, if necessary monitor the sequence, changing flash-off timer and traverse speed as required. When the sequence is complete remember to check material level in the gun reservoir and that status switches, timer and counter are all set is required. Press emergency stop switch then reset before starting another cycle.

Page 17: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

16

14.0 Panel Sprayers - Standard Specifications

Function/Sprayer Model SH0586 SH0582 Spray guns(s) facility

1 Spray gun selector switch Spray gun to panel distance, adjustable, (mm) dependent on spray gun type

Spray Gun stroke length. (mm) 400 fixed Spray pressure, 0.5 to 5 bar ✔ Spray area, max with 1 gun (mm) 350 x 500 Traverse speed, adjustable 20 – 800 mm/sec ✔

Panel-lift increments between coats. (mm) 40 & 50 10 to 500 customer specification

1 Flash-off Timer, (0 – 10 minutes between coats) ✔

2 Flash-off timers (Guns 1 & 2) (minutes between coats)

-

Coats Counter. (adjustable 1 – 9999 coats) 1 Passes Counter. (adjustable 1 – 9999 coats) Manual control- Spray on/off, traverse lift.

✔ Magnetic Panel Holder Number of sample panels, 100 x 1500 mm 4 Power supply - pneumatic, 10 bar (150 psi) ✔ Standard dimensions. (without optional equipment) (cm)

70 width x 72 depth x 160 high (panel at full lift height)

Net Weight (kg) 70

15.0 Optional equipment One or more of the following options may have been supplied with the Panel Sprayer (See your Purchase Order for details).

Function/Sprayer Model SH0586 SH0582 Vacuum holder. (for non-magnetic panels, with individual quick release

SH1706 SH1706 ✔

16.0 Product Compliances 16.1 Functional Compliance The Pneumatic Panel Sprayers comply to the requirements of ASTM D823/A

16.2 Safety Compliance The instruction manual should be kept in proximity to where the instrument operates and should be visible and accessible at any time of operation.

In addition to the information contained in the instruction manual, general and local regulations for accident prevention and environmental protection shall be kept available and observed. Always ensure all guidelines in respect of safety and dangers on the instrument are in readable condition.

Page 18: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

17

In case of danger the instrument has to be switched off by means of the on / off switch or by unplugging the mains power, then the danger should be eliminated.

Dangers from Electrical Energy:

• Work on the electrical supply may only be done by a qualified electrician.

• The electrical equipment of the instrument must be checked regularly. Loose connections and damaged cables must be corrected immediately.

• Always make sure the instrument’s power is turned off while adjusting any electrical component.

• Make sure that no paint or other liquids are spilled on the electronics

Modifications to the Equipment:

• Any modifications or additions or alterations to the instrument may solely be made with permission from the manufacturer otherwise the warranty will be void.

• Instruments which are not in fault-free condition must immediately be switched off

• Only use replacement parts from the original supplier. Parts used from other sources aren’t guaranteed to take the loading and meet the safety requirements.

17.0 Associated Products

To contribute towards obtaining consistent film application we recommend the following products:

17.1 Test Panels We offer a range of steel and aluminium panels for the Sprayers to ensure constancy of the surfaces for film application.

17.2 Wet film thickness gauges To obtain the optimum Panel Sprayer settings (speed of application, panel lift, gun settings.) these gauges offer a quick method of checking the wet film thickness at the application stage. This is partially important when in determining the % loss between wet and subsequent dry film thickness. 17.3 Further information on Accessories For further information on these products, also for products for use after the coating film has cured. (Dry film Thickness Gauges, Gloss, Opacity and Colour Meters) visit our website www.tqcsheen.com

Page 19: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

18

18.0 Maintenance

18.1 Safety Any work carried out on mechanical parts within the machine frame should be performed with caution. Please note that cover panels are NOT safety interlocked so the system should be isolated from mains air pressure using the ISOLATION SWITCH (inside right hand side panel).

To operate, press the cap down and this will vent the system.

NOTE: To reset isolation switch press orange button inside cap.

18.2 Compressed Air Filter The filter is intended to remove moisture from the mains air supply. As water collects in the bowl of the filter it is necessary to regularly check the filter bowl to ensure that water does not accumulate to such an extent that it could enter the control system. This may be caused by a particularly damp supply or a sudden surge in the moisture content. To manually release accumulated water, the water release valve at the base of the bowl should be unscrewed one or two turns. The valve should never be fully unscrewed. Tighten the valve again after the water has drained.

18.3 Traverse Assembly WARNING: In the event of any adjustment being made, main air must be disconnected.

With traverse cylinder mounted onto frame and gun post assembly fitted carryout following checks: 1. Check for free and smooth movement in both directions – Set Speed controller to a low figure e.g. 10-

20. Press emergency stop any operate manual left/right switch. 2. Check for no lateral movement of carriage by pushing and pulling gun post.

The carriage slide system can be adjusted if necessary as detailed below. To adjust the carriage slide loosen grub screw, these lock adjusting screws. If carriage is loose:

1. Slacken screws “A”. 2. Turn screws “B” clockwise in small increments ensuring even adjustment. 3. Tighten screws ”A”.

Reverse if carriage is too tight.

Page 20: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

19

18.4 General Inspection • Check for air leaks. • Inspect brushes for wear. • Check panel lift assembly is secure. • Check the security of the earth stud connection.

18.5 Fault finding The level of fault finding is limited to checking that the main functions are operating correctly and conducting elementary level inspection and checking.

Pneumatics Engineer For full investigation of finding faults the skills level required is that of a trained pneumatics engineer this is outside the general scope of the customer’s operators and engineers, should the occasion arise when a full investigation is required please contact our Service Dept. who will be able to advise accordingly.

The nature of the fault finding listed in this manual is first stage investigation, this will enable the local engineer to check that the operator settings are functioning correctly and can relay the information to TQC Sheen Service engineers.

18.6 Pre-Fault Finding Checks Prior to fault finding check the following:

1) Main air supply on at 6 – 6.5 bar (90 to 100 psi). 2) Counters are reset and pre-set value is not less than 1. 3) Manual/auto switch is set to AUTO. 4) Check for air leaks. (Supply line, couplings etc.)

In the event of a fault occurring reset the sprayer to its start condition in the following manner: 1) Press the emergency stop 2) Switch the reset on and hold until both LIFT and TRAVERSE cylinders are returned to their start positions.

18.7 Panel Sprayer Fault Finding Machine will not start when START button is pressed:

• Check the air supply to the machine is supplying approximately 6.5 bar (100PSI) • Check the machine is turned on • Check the machine is reset fully • Check the lift cylinder carriage is fully retracted and is sitting on limit switch. If carriage is on the

switch then the switch could be faulty. 18.8 Traverse faults When the start button is pressed, the traverse cylinder should go from left to right.

• If the cylinder goes from left to right, sprays, and then returns straight away then check the counter is set up. Check the counter is not giving a continuous output by removing the A output pipe from the coats counter, and checking that air is coming from the counter. If air is coming from the output, try resetting the machine and also press the manual reset button on the front of the counter. If the fault still occurs, a new counter will be required.

Page 21: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

20

• If the machine traverses from left to right then returns straight away then lifts then repeats this until it reaches the number of passes then returns to the start position, this is usually caused by one of the logic elements on the logic module become faulty. This will require changing and the services of an service engineer.

• If the traverse travels one way fast and back the other way slow, the cylinder seals could be worn. To check this, open the door on the machine and listen for air leaks from the cylinder. Also, the internal seals could be worn. To check these turn the air supply off to the machine and disconnect the pipes to the cylinder. Apply an air supply to one end of the cylinder (turn air on slowly), the cylinder should then traverse to the other end if air still comes out of the cylinder once it has reached the end then the seals are worn. Repeat for the other end of the cylinder.

18.9 Machine Stops in Mid Cycle (Lift Cylinder Faults) If the machine stops during the cycle check:

1) The speed of the lift cylinder is not too quick when it lifts, this can cause the magnetic reed switches on the carriage to miss the contacts, which will in turn stop the machine. To adjust the speed of the cylinder there is a flow restrictor at the top and the bottom of the cylinder which when adjusted will speed up or slow down the cylinder.

2) Check the magnetic switches are set up properly, e.g. the distance between the switch and the switch contact (gap should be between 1mm/2mm).

3) Check the switches are working (when the switch gives an output, the indicator button should be sticking out. If not, replace the switch.

4) If the cylinder is not lifting try adjusting the flow restrictors on the cylinder, and adjust the cylinder carriage by loosening the ten adjusting screws on the side of the carriage.

Page 22: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

21

19.0 Service & Contact Information 19.1 Training We can offer training in use of the machines, please contact our Sales Dept. [email protected] 19.2 Product Service We can offer service contracts for maintaining the machines, contact our Service Dept. (See below) It is recommended that these machines are subject to regular service in order to ensure that they operate to the designed specifications. 19.3 Fault Reporting TQC Sheen can offer a degree of product support by electronic communication, (email, telephone, video) you should always state the following information regarding any communications:

• Product model reference • Serial number • Age of machine and or when last serviced. • Name of enquirer • Location address • Phone numbers and email address. • Description of the fault, any supporting images and/ or videos.

19.4 Service Contact & address For all enquiries please contact: [email protected] Service Address TQC Sheen B.V. Molenbaan 19 2908LL Capelle aan den IJssel The Netherlands Phone: +31 (0) 10 – 7900-100 Email: [email protected]

Page 23: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

22

Page 24: Model SH0586 & SH0582 Small Automatic Panel Sprayer ......9.1 Manual/Off/Auto Switch This switch provides control of 3 functions. With the switch set to Off the cycle cannot be started,

23

This material is copyrighted by TQC Sheen B.V. and may not be reproduced in whole or in part by any means of information storage, retrieval, or reproduction without written permission from TQC Sheen B.V.

COPYRIGHT© 2019 TQC Sheen B.V.