CMB-WM-V-AACMB-WM-V-AB
MODEL
EIo-1
AIR CONDITIONING SYSTEMS
HBC controller Indoor units
CMB-WM-V-AA, CMB-WM-V-AB (for YNW/YLM-Series)
MEES17K102 EIo-1 1
I.HBC controller
1.SPECIFICATIONS ........................................................................................................................................... 2
2.EXTERNAL DIMENSIONS .............................................................................................................................. 6
3.CENTER OF GRAVITY ................................................................................................................................. 10
4.ELECTRICAL WIRING DIAGRAMS .............................................................................................................. 11
5.SOUND LEVELS ........................................................................................................................................... 15
5-1. Sound levels ......................................................................................................................................... 155-2. NC curves ............................................................................................................................................. 15
6.ELECTRICAL CHARACTERISTICS.............................................................................................................. 16
0000004671.BOOK 1 ページ 2018年3月13日 火曜日 午前11時9分
1. SPECIFICATIONS Indoor units
MEES17K102
HB
C c
on
tro
ller
2EIo-1
I.HBC controller1. SPECIFICATIONS
Model name CMB-WM108V-AA
Number of branch 8
Power source 1-phase 220-230-240 V
50 Hz 60 Hz
Power input Cooling kW 0.45/0.46/0.47 0.45/0.46/0.47
(220/230/240) Heating kW 0.45/0.46/0.47 0.45/0.46/0.47
Current input Cooling A 2.89/2.83/2.79 2.89/2.83/2.79
(220/230/240) Heating A 2.89/2.83/2.79 2.89/2.83/2.79
Sound pressure level (measured in anechoice room) dB <A> 41
Applicable temperature range of installation site °C (D.B.) 0~32
External finish Galvanized steel plate
(Lower part drain pan: Pre-coated galvanized sheets + powder coating)
Connectable outdoor/heat source unitPURY-P200~500YNW-A(-BS)/PURY-EP200~500YNW-A(-BS)PURY-M200~300YNW-A(-BS)/PURY-EM200~300YNW-A(-BS)
PURY-P200~500YLM-A(1)(-BS)/PURY-EP200~500YLM-A1(-BS)/PQRY-P200~500YLM-A2/A1
Indoor unit capacity connectable to 1 branchModel P80 or smaller
(Use optional joint pipe combing 2 branches when the total unit capacity exceeds P81)
External dimension H x W x Dmm 300 x 1,520 x 630
in. 11-13/16 x 59-7/8 x 24-13/16
Refrigerant piping diameter
To outdoor/heat source unit
Connectable outdoor/heat source unit capacity
To P200To M300
To P250/300 To P350 To P400 for each To P450/500 for each
High press. Pipemm (in.)
O.D.15.88 (5/8)
Brazed19.05 (3/4)
Brazed19.05 (3/4)
Brazed15.88 (5/8)
Brazed19.05 (3/4)
Brazed
Low press. Pipemm (in.)
O.D.19.05 (3/4)
Brazed22.2 (7/8)Brazed
28.58 (1-1/8)Brazed
19.05 (3/4)Brazed
22.2 (7/8)Brazed
Water piping diameter
To Indoor unit
Inlet Pipemm (in.)
I.D.20 (3/4)
Outlet Pipemm (in.)
I.D.20 (3/4)
Field drain pipe size mm (in.) O.D. 32 (1-1/4)
Net weight kg (lbs) 86 (190) [96 (212) with water]
Standardattachment
Document –
Accessory Drain Connection pipe (with flexible hose and insulation)
Optional parts –
Note 1.Works not included: Installation/foundation work, electrical connection work, duct work, insulation work, power source switch, and other items are not specified in this specifications.
2.The equipment is for R410A/R32 refrigerant.
3.Install this product in a location where noise (refrigerant noise) emitted by the unit will not disturb the neighbors. (For use in quiet environments with low background noise, position the HBC CONTROLLER at least 5 m away from any indoor units.)
4.Please install the HBC controller in a place where noise will not be an issue.
5.Please attach an expansion vessel (field supply).
6.Please use copper or plastic pipes for the water circuit. Do not use steel or stainless steel pipework. Furthermore, when using copper pipework use a non-oxidative brazing method. Oxidation of the pipework will reduce the pump life.
7.When brazing the pipes, be sure to braze, after covering a wet cloth to the insulation pipes of the units in order to prevent it from burning and shrinking by heat.
8.Please install an air purge valve where air will gather in the water circuit.
9.Please install a pressure reducing valve and a strainer on the water supply to the HBC controller.
10.Please refer to the databook or the installation manual for the specified water quality.
11.This unit is not designed for outside installations.
12.Please always make water circulate or pull out the circulation water completely when not using it. *Please do not use it as a drinking water.
13.Please do not use ground water and well water.
14.When installing the HBC unit in an environment which may drop below 0 °C, please add antifreeze to the circulating water. (Refer to the databook and the installation manual).
15.R32 is flammable, and certain restrictions apply to the installation of units. When installing new units, moving the existing units, or changing the layout of the room, ensure that installation restrictions are observed. For detail, refer to the section in the Databook on installation restrictions.
0000004671.BOOK 2 ページ 2018年3月13日 火曜日 午前11時9分
1. SPECIFICATIONS Indoor units
MEES17K102
HB
C co
ntro
ller
3EIo-1
Model name CMB-WM1016V-AA
Number of branch 16
Power source 1-phase 220-230-240 V
50 Hz 60 Hz
Power input Cooling kW 0.45/0.46/0.47 0.45/0.46/0.47
(220/230/240) Heating kW 0.45/0.46/0.47 0.45/0.46/0.47
Current input Cooling A 2.89/2.83/2.79 2.89/2.83/2.79
(220/230/240) Heating A 2.89/2.83/2.79 2.89/2.83/2.79
Sound pressure level (measured in anechoice room) dB <A> 41
Applicable temperature range of installation site °C (D.B.) 0~32
External finishGalvanized steel plate
(Lower part drain pan: Pre-coated galvanized sheets + powder coating)
Connectable outdoor/heat source unitPURY-P200~500YNW-A(-BS)/PURY-EP200~500YNW-A(-BS)PURY-M200~300YNW-A(-BS)/PURY-EM200~300YNW-A(-BS)
PURY-P200~500YLM-A(1)(-BS)/PURY-EP200~500YLM-A1(-BS)/PQRY-P200~500YLM-A2/A1
Indoor unit capacity connectable to 1 branchModel P80 or smaller
(Use optional joint pipe combing 2 branches when the total unit capacity exceeds P81)
External dimension H x W x Dmm 300 x 1,800 x 630
in. 11-13/16 x 70-7/8 x 24-13/16
Refrigerant piping diameter
To outdoor/heat source unit
Connectable outdoor/heat source unit capacity
To P200To M300
To P250/300 To P350 To P400 for each To P450/500 for each
High press. Pipemm (in.)
O.D.15.88 (5/8)
Brazed19.05 (3/4)
Brazed19.05 (3/4)
Brazed15.88 (5/8)
Brazed19.05 (3/4)
Brazed
Low press. Pipemm (in.)
O.D.19.05 (3/4)
Brazed22.2 (7/8)
Brazed28.58 (1-1/8)
Brazed19.05 (3/4)
Brazed22.2 (7/8)
Brazed
Water piping diameter
To Indoor unit
Inlet Pipemm (in.)
I.D.20 (3/4)
Outlet Pipemm (in.)
I.D.20 (3/4)
Field drain pipe size mm (in.) O.D. 32 (1-1/4)
Net weight kg (lbs) 98 (217) [111 (245) with water]
Standardattachment
Document –
Accessory Drain Connection pipe (with flexible hose and insulation)
Optional parts –
Note 1.Works not included: Installation/foundation work, electrical connection work, duct work, insulation work, power source switch, and other items are not specified in this specifications.
2.The equipment is for R410A/R32 refrigerant.
3.Install this product in a location where noise (refrigerant noise) emitted by the unit will not disturb the neighbors. (For use in quiet environments with low background noise, position the HBC CONTROLLER at least 5 m away from any indoor units.)
4.Please install the HBC controller in a place where noise will not be an issue.
5.Please attach an expansion vessel (field supply).
6.Please use copper or plastic pipes for the water circuit. Do not use steel or stainless steel pipework. Furthermore, when using copper pipework use a non-oxidative brazing method. Oxidation of the pipework will reduce the pump life.
7.When brazing the pipes, be sure to braze, after covering a wet cloth to the insulation pipes of the units in order to prevent it from burning and shrinking by heat.
8.Please install an air purge valve where air will gather in the water circuit.
9.Please install a pressure reducing valve and a strainer on the water supply to the HBC controller.
10.Please refer to the databook or the installation manual for the specified water quality.
11.This unit is not designed for outside installations.
12.Please always make water circulate or pull out the circulation water completely when not using it. *Please do not use it as a drinking water.
13.Please do not use ground water and well water.
14.When installing the HBC unit in an environment which may drop below 0 °C, please add antifreeze to the circulating water. (Refer to the databook and the installation manual).
15.R32 is flammable, and certain restrictions apply to the installation of units. When installing new units, moving the existing units, or changing the layout of the room, ensure that installation restrictions are observed. For detail, refer to the section in the Databook on installation restrictions.
0000004671.BOOK 3 ページ 2018年3月13日 火曜日 午前11時9分
1. SPECIFICATIONS Indoor units
MEES17K102
HB
C c
on
tro
ller
4EIo-1
Model name CMB-WM108V-AB
Number of branch 8
Power source 1-phase 220-230-240 V
50 Hz 60 Hz
Power input Cooling kW 0.01/0.01/0.01 0.01/0.01/0.01
(220/230/240) Heating kW 0.01/0.01/0.01 0.01/0.01/0.01
Current input Cooling A 0.05/0.05/0.05 0.05/0.05/0.05
(220/230/240) Heating A 0.05/0.05/0.05 0.05/0.05/0.05
Sound pressure level (measured in anechoice room) dB <A> –
Applicable temperature range of installation site °C (D.B.) 0~32
External finish Galvanized steel plate
(Lower part drain pan: Pre-coated galvanized sheets + powder coating)
Connectable outdoor/heat source unit –
Indoor unit capacity connectable to 1 branchModel P80 or smaller
(Use optional joint pipe combing 2 branches when the total unit capacity exceeds P81)
External dimension H x W x Dmm 300 x 1,520 x 630
in. 11-13/16 x 59-7/8 x 24-13/16
Refrigerant piping diameter
To outdoor/heat source unitConnectable outdoor/heat source unit capacity
– – – – –
High press. Pipemm (in.)
O.D.– – – – –
Low press. Pipemm (in.)
O.D.– – – – –
Water piping diameter
To Indoor unit
Inlet Pipemm (in.)
I.D.20 (3/4)
Outlet Pipemm (in.)
I.D.20 (3/4)
Field drain pipe size mm (in.) O.D. 32 (1-1/4)
Net weight kg (lbs) 44 (98) [49 (109) with water]
Standardattachment
Document –
Accessory Drain Connection pipe (with flexible hose and insulation)
Optional parts –
Note 1.Works not included: Installation/foundation work, electrical connection work, duct work, insulation work, power source switch, and other items are not specified in this specifications.
2.The equipment is for water.
3.Install this product in a location where noise (refrigerant noise) emitted by the unit will not disturb the neighbors. (For use in quiet environments with low background noise, position the Sub HBC CONTROLLER at least 5 m away from any indoor units.)
4.Please install the Sub HBC controller in a place where noise will not be an issue.
5.Please attach an expansion vessel (field supply).
6.Please use copper or plastic pipes for the water circuit. Do not use steel or stainless steel pipework. Furthermore, when using copper pipework use a non-oxidative brazing method. Oxidation of the pipework will reduce the pump life.
7.When brazing the pipes, be sure to braze, after covering a wet cloth to the insulation pipes of the units in order to prevent it from burning and shrinking by heat.
8.Please install an air purge valve where air will gather in the water circuit.
9.Please refer to the databook or the installation manual for the specified water quality.
10.This unit is not designed for outside installations.
11.Please always make water circulate or pull out the circulation water completely when not using it. *Please do not use it as a drinking water.
12.Please do not use ground water and well water.
13.When installing the Sub HBC unit in an environment which may drop below 0 °C, please add antifreeze to the circulating water. (Refer to the databook and the installation manual).
14.Can't use singleness. (MAIN HBC CONTROLLER is necessary)
0000004671.BOOK 4 ページ 2018年3月13日 火曜日 午前11時9分
1. SPECIFICATIONS Indoor units
MEES17K102
HB
C co
ntro
ller
5EIo-1
Model name CMB-WM1016V-AB
Number of branch 16
Power source 1-phase 220-230-240 V
50 Hz 60 Hz
Power input Cooling kW 0.01/0.01/0.01 0.01/0.01/0.01
(220/230/240) Heating kW 0.01/0.01/0.01 0.01/0.01/0.01
Current input Cooling A 0.05/0.05/0.05 0.05/0.05/0.05
(220/230/240) Heating A 0.05/0.05/0.05 0.05/0.05/0.05
Sound pressure level (measured in anechoice room) dB <A> –
Applicable temperature range of installation site °C (D.B.) 0~32
External finishGalvanized steel plate
(Lower part drain pan: Pre-coated galvanized sheets + powder coating)
Connectable outdoor/heat source unit –
Indoor unit capacity connectable to 1 branchModel P80 or smaller
(Use optional joint pipe combing 2 branches when the total unit capacity exceeds P81)
External dimension H x W x Dmm 300 x 1,520 x 630
in. 11-13/16 x 59-7/8 x 24-13/16
Refrigerant piping diameter
To outdoor/heat source unitConnectable outdoor/heat source unit capacity
– – – – –
High press. Pipemm (in.)
O.D.– – – – –
Low press. Pipemm (in.)
O.D.– – – – –
Water piping diameter
To Indoor unit
Inlet Pipemm (in.)
I.D.20 (3/4)
Outlet Pipemm (in.)
I.D.20 (3/4)
Field drain pipe size mm (in.) O.D. 32 (1-1/4)
Net weight kg (lbs) 53 (117) [62 (137) with water]
Standardattachment
Document –
Accessory Drain Connection pipe (with flexible hose and insulation)
Optional parts –
Note 1.Works not included: Installation/foundation work, electrical connection work, duct work, insulation work, power source switch, and other items are not specified in this specifications.
2.The equipment is for water.
3.Install this product in a location where noise (refrigerant noise) emitted by the unit will not disturb the neighbors. (For use in quiet environments with low background noise, position the Sub HBC CONTROLLER at least 5 m away from any indoor units.)
4.Please install the Sub HBC controller in a place where noise will not be an issue.
5.Please attach an expansion vessel (field supply).
6.Please use copper or plastic pipes for the water circuit. Do not use steel or stainless steel pipework. Furthermore, when using copper pipework use a non-oxidative brazing method. Oxidation of the pipework will reduce the pump life.
7.When brazing the pipes, be sure to braze, after covering a wet cloth to the insulation pipes of the units in order to prevent it from burning and shrinking by heat.
8.Please install an air purge valve where air will gather in the water circuit.
9.Please refer to the databook or the installation manual for the specified water quality.
10.This unit is not designed for outside installations.
11.Please always make water circulate or pull out the circulation water completely when not using it. *Please do not use it as a drinking water.
12.Please do not use ground water and well water.
13.When installing the Sub HBC unit in an environment which may drop below 0 °C, please add antifreeze to the circulating water. (Refer to the databook and the installation manual).
14.Can't use singleness. (MAIN HBC CONTROLLER is necessary)
0000004671.BOOK 5 ページ 2018年3月13日 火曜日 午前11時9分
2. EXTERNAL DIMENSIONS Indoor units
MEES17K102
HB
C c
on
tro
ller
6EIo-1
2. EXTERNAL DIMENSIONS
412
7070X
7=49
0
447
70 70X
7=49
0
74148153180
84154
73103
151181
4351
93
54090
157 21
622
4 272
286
1321 13
91 1520
1379
543
3
300
200
4427
6
31
93
93
Dra
in p
ipin
g V
P-2
5 C
onne
ctio
n
Con
nect
ion
pipe
to S
UB
HB
C
Con
nect
ion
pipe
from
SU
B H
BC
Con
nect
ion
pipe
from
SU
B H
BC
Con
nect
ion
pipe
to S
UB
HB
C
Con
nect
ion
pipe
from
indo
or u
nit
Con
nect
ion
pipe
to in
door
uni
t
Con
nect
ion
pipe
from
MA
IN H
BC
Wat
er p
ipe(
Inle
t)
Wat
er p
ipe(
EX
P.Ta
nk)
X
Con
nect
ion
pipe
of
outd
oor/h
eat s
ourc
e un
it
Con
nect
ion
pipe
of
outd
oor/h
eat s
ourc
e un
it
Z
Y
ø31
Dra
in h
ose
I.D.3
2(1-
1/4"
) (A
cces
sory
)
Ban
d(A
cces
sory
)
Cut
ting
poin
t
1230
14
100 120200(700)
250
160
300
160
450
450
450
(Lift
ing
bolt
pitc
h)
Con
trol b
ox
(Lifting bolt pitch)
12
34
56
78
ø22.
0(us
e at
tach
men
t pip
e)[F
ield
sup
ply]
ø22.
0(us
e at
tach
men
t pip
e)[F
ield
sup
ply]
(Hig
h pr
essu
re)
ø22.
2<B
raze
d>
(Low
pre
ssur
e)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
ø15.
88<B
raze
d>
ø19.
05<B
raze
d>
Det
ail o
f X s
ectio
nD
etai
l of Z
sec
tion
Det
ail o
f Y s
ectio
n
Ser
vice
spa
ce
Ser
vice
spa
ce
Ser
vice
spa
ce
Ser
vice
spac
e
Acc
ess
door
Acc
ess
door
<Acc
esso
ries>
·Dra
in h
ose
I.D.3
2(1-
1/4"
)···
····
····
····
····
··1p
c.·H
ose
band
····
····
····
····
····
····
····
····
····
····
1pc.
·Tie
ban
d···
····
····
····
····
····
····
····
····
····
····
1pc.
Not
e1. S
uspe
nsio
n bo
lt(ø1
0),w
ashe
r(M
10),a
nd n
ut(M
10)
prep
are
in th
e fie
ld.
2. T
ake
notic
e of
ser
vice
spa
ce a
s fo
llow
s.(P
leas
e gi
ve a
ttent
ion
not t
o oc
cupy
ser
vice
spa
ce b
y le
tting
duc
ts a
nd p
ipes
thro
ugh.
)
·Wre
nch·
····
····
····
····
····
····
····
····
····
····
···1
pc.
CMB-WM108V-AAUnit : mm
0000004671.BOOK 6 ページ 2018年3月13日 火曜日 午前11時9分
2. EXTERNAL DIMENSIONS Indoor units
MEES17K102
HB
C co
ntro
ller
7EIo-1
543
1800
447
7070
X15
=105
0
7070
X15
=105
041
2
74148153180
84
73
103151
181
157 21
622
4 272
286
1601 167116
59
54090
4351
93 154
300
3
4427
6
200
31
93
93
Con
nect
ion
pipe
to S
UB
HB
C
Con
nect
ion
pipe
from
SU
B H
BC
Con
nect
ion
pipe
from
SU
B H
BC
Con
nect
ion
pipe
to S
UB
HB
C
Con
nect
ion
pipe
to in
door
uni
t
Con
nect
ion
pipe
of
outd
oor/h
eat s
ourc
e un
it
Con
nect
ion
pipe
of
outd
oor/h
eat s
ourc
e un
it
Con
nect
ion
pipe
from
MA
IN H
BC
Wat
er p
ipe(
Inle
t)
Wat
er p
ipe(
EX
P.Ta
nk)
Con
nect
ion
pipe
from
indo
or u
nit
XZ
Y
Dra
in p
ipin
g V
P-2
5 C
onne
ctio
n
ø31
Dra
in h
ose
I.D.3
2(1-
1/4"
) (A
cces
sory
)
Ban
d(A
cces
sory
)
Cut
ting
poin
t
1230
14
200(700)
300
300
300
100 120250
450
450
450
(Lifting bolt pitch)
(Lift
ing
bolt
pitc
h)
12
34
56
78
910
1112
1314
1516
Con
trol b
ox
[Fie
ld s
uppl
y]
[Fie
ld s
uppl
y]
ø22.
0(us
e at
tach
men
t pip
e)[F
ield
sup
ply]
(Hig
h pr
essu
re)
ø22.
2<B
raze
d>
(Low
pre
ssur
e)
[Fie
ld s
uppl
y]
ø22.
0(us
e at
tach
men
t pip
e)[F
ield
sup
ply]
ø22.
0(us
e at
tach
men
t pip
e)[F
ield
sup
ply] ø2
2.0(
use
atta
chm
ent p
ipe)
ø22.
0(us
e at
tach
men
t pip
e)
ø22.
0(us
e at
tach
men
t pip
e)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
ø15.
88<B
raze
d>
ø19.
05<B
raze
d>
Det
ail o
f X s
ectio
nD
etai
l of Z
sec
tion
Det
ail o
f Y s
ectio
n
Ser
vice
spac
e
Ser
vice
spa
ce
Ser
vice
spa
ce
Acc
ess
door
Acc
ess
door
Ser
vice
spa
ce
<Acc
esso
ries>
·Dra
in h
ose
I.D.3
2(1-
1/4"
)···
····
····
····
····
··1p
c.·H
ose
band
····
····
····
····
····
····
····
····
····
····
1pc.
·Tie
ban
d···
····
····
····
····
····
····
····
····
····
····
1pc.
Not
e1. S
uspe
nsio
n bo
lt(ø1
0),w
ashe
r(M
10),a
nd n
ut(M
10)
prep
are
in th
e fie
ld.
2. T
ake
notic
e of
ser
vice
spa
ce a
s fo
llow
s.(P
leas
e gi
ve a
ttent
ion
not t
o oc
cupy
ser
vice
spa
ce b
y le
tting
duc
ts a
nd p
ipes
thro
ugh.
)
·Wre
nch·
····
····
····
····
····
····
····
····
····
····
···1
pc.
CMB-WM1016V-AAUnit : mm
0000004671.BOOK 7 ページ 2018年3月13日 火曜日 午前11時9分
2. EXTERNAL DIMENSIONS Indoor units
MEES17K102
HB
C c
on
tro
ller
8EIo-1
(Lifting bolt pitch)
(Lift
ing
bolt
pitc
h)
Con
trol b
ox
ø22.
0(us
e at
tach
men
t pip
e)[F
ield
sup
ply]
ø22.
0(us
e at
tach
men
t pip
e)[F
ield
sup
ply]
12
34
56
78
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
Det
ail o
f X s
ectio
nD
etai
l of Z
sec
tion
Det
ail o
f Y s
ectio
n
Ser
vice
spa
ce
Ser
vice
spa
ce
Ser
vice
spa
ce
Ser
vice
spac
e
Acc
ess
door
Acc
ess
door
<Acc
esso
ries>
·Dra
in h
ose
I.D.3
2(1-
1/4"
)···
····
····
····
····
··1p
c.·H
ose
band
····
····
····
····
····
····
····
····
····
····
1pc.
·Tie
ban
d···
····
····
····
····
····
····
····
····
····
····
1pc.
Not
e1. S
uspe
nsio
n bo
lt(ø1
0),w
ashe
r(M
10),a
nd n
ut(M
10)
prep
are
in th
e fie
ld.
2. T
ake
notic
e of
ser
vice
spa
ce a
s fo
llow
s.(P
leas
e gi
ve a
ttent
ion
not t
o oc
cupy
ser
vice
spa
ce b
y le
tting
duc
ts a
nd p
ipes
thro
ugh.
)
73103
141171
84
154
290
7070X
7=49
0
325
70 70X
7=49
0
54090
543
1379
149 21
915
20
300
93
3
200
276
44
52
Con
nect
ion
pipe
from
MA
IN H
BC
Dra
in p
ipin
g V
P-2
5 C
onne
ctio
n
Con
nect
ion
pipe
from
MA
IN H
BC
Con
nect
ion
pipe
to M
AIN
HB
C
Con
nect
ion
pipe
to M
AIN
HB
C
Con
nect
ion
pipe
from
indo
or u
nit
Con
nect
ion
pipe
to in
door
uni
t
X
Y
Z
ø31
Dra
in h
ose
I.D.3
2(1-
1/4"
) (A
cces
sory
)
Ban
d(A
cces
sory
)
Cut
ting
poin
t
1230
14
100 120200(700)
250
160
300
160
450
450
450
CMB-WM108V-ABUnit : mm
0000004671.BOOK 8 ページ 2018年3月13日 火曜日 午前11時9分
2. EXTERNAL DIMENSIONS Indoor units
MEES17K102
HB
C co
ntro
ller
9EIo-1
(Lifting bolt pitch)
(Lift
ing
bolt
pitc
h)
Con
trol b
ox
ø22.
0(us
e at
tach
men
t pip
e)[F
ield
sup
ply]
ø22.
0(us
e at
tach
men
t pip
e)[F
ield
sup
ply]
12
34
56
78
910
1112
1314
1516
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
[Fie
ld s
uppl
y]ø2
2.0(
use
atta
chm
ent p
ipe)
Det
ail o
f X s
ectio
nD
etai
l of Z
sec
tion
Det
ail o
f Y s
ectio
n
Ser
vice
spa
ce
Ser
vice
spa
ce
Ser
vice
spa
ce
Ser
vice
spac
e
Acc
ess
door
Acc
ess
door
<Acc
esso
ries>
·Dra
in h
ose
I.D.3
2(1-
1/4"
)···
····
····
····
····
··1p
c.·H
ose
band
····
····
····
····
····
····
····
····
····
····
1pc.
·Tie
ban
d···
····
····
····
····
····
····
····
····
····
····
1pc.
Not
e1. S
uspe
nsio
n bo
lt(ø1
0),w
ashe
r(M
10),a
nd n
ut(M
10)
prep
are
in th
e fie
ld.
2. T
ake
notic
e of
ser
vice
spa
ce a
s fo
llow
s.(P
leas
e gi
ve a
ttent
ion
not t
o oc
cupy
ser
vice
spa
ce b
y le
tting
duc
ts a
nd p
ipes
thro
ugh.
)
73103
141171
84
154
290
7070
X15
=105
0
325
7070
X15
=105
0
54090
543
1379
149 21
915
20
300
93
344
276
200
52
Con
nect
ion
pipe
from
indo
or u
nit
Con
nect
ion
pipe
to in
door
uni
t
Con
nect
ion
pipe
from
MA
IN H
BC
Dra
in p
ipin
g V
P-2
5 C
onne
ctio
n
Con
nect
ion
pipe
from
MA
IN H
BC
Con
nect
ion
pipe
to M
AIN
HB
C
Con
nect
ion
pipe
to M
AIN
HB
C
X
Y
Z
ø31
Dra
in h
ose
I.D.3
2(1-
1/4"
) (A
cces
sory
)
Ban
d(A
cces
sory
)
Cut
ting
poin
t
1230
14
100 120200(700)
250
160
300
160
450
450
450
CMB-WM1016V-ABUnit : mm
0000004671.BOOK 9 ページ 2018年3月13日 火曜日 午前11時9分
3. CENTER OF GRAVITY Indoor units
MEES17K102
HB
C c
on
tro
ller
10EIo-1
3. CENTER OF GRAVITY
CMB-WM108, 1016V-AACMB-WM108, 1016V-AB
xz
y
543 A
Center of gravityIndoor unit branching point
A (mm)x (mm)y (mm)z (mm)
CMB-WM108V-AA1379680145285
CMB-WM1016V-AA1659825145285
CMB-WM108V-AB1379610145270
CMB-WM1016V-AB1379680145270
0000004671.BOOK 10 ページ 2018年3月13日 火曜日 午前11時9分
4. ELECTRICAL WIRING DIAGRAMS Indoor units
MEES17K102
HB
C co
ntro
ller
11EIo-1
4. ELECTRICAL WIRING DIAGRAMS
NO
TE:1
. TB
02 is
tran
smis
sion
term
inal
blo
ck.
Nev
er c
onne
ct p
ower
line
to it
.
2. T
he in
itial
set
val
ues
of s
witc
h on
C
ontro
l Boa
rd a
re a
s fo
llow
s.
SW
1:0
S
W2:
0
Det
ail o
f X s
ectio
n
LED
1 SW
1S
W2
SWP2
SWP1
SWP3
110
X
DS
A00
1
(Blu
e)(Y
ello
w)
(Gre
en)
(Red
)
(Gre
en)
(Gre
en)
(Blu
e)
(Blu
e)
(Yel
low
)
(Red
)
(Red
)
(Blu
e)
(Red
)(R
ed)
(Red
)
(Red
)
F001
250V
AC
6.3A
F
TO N
EXT
IND
OO
R U
NIT
PULL
BO
X
FUSE
(16A
)BR
EAKE
R(1
6A)
POW
ER S
UPP
LY~2
20V-
240V
50H
z/60
Hz
Indo
or/o
utdo
orTr
ansm
issi
on L
ine
t°t° t°t°t°t° t° t° t°t°t°t° t°t°t°t° t°t°
MMM
UU
X00
2
X00
6
X00
3
AC
L
SV
1
21S4
Mb21
S4Ma
ZNR0
01
L001
ZNR0
02
C004
C006
C003
C005
C002
C007
LEV1
LEV2
LEV3
WP1
WP2
1 3
1
7
2
6
3
5
4
4
5
3
6
2
1
2
32
1
7
1
2
1
11
1
11
22
33
22
2
33
34
11
24
45
56
6
PS
1P
S3
FS
TH12
TH11
TH31
c
TH31
b
TH31
a
TH31
f
TH31
d
TH13
TH14
TH31
e
TH31
hTH
31g
TH34
TH35
TH16
TH33
TH15
TH32
66
65
55
44
43
33
22
21
11
Con
trol B
oard
Pow
er B
oard
111
1 1
11
1
3
1111 222
2 2
22
2
1
2222 333
3 3
33
3
3333 444
4 4
55
4
4444 555
5 5
77
5
55 666
6 67 7
99
6
6531
13
55
37
1
S(SH
IELD
)TB02
M2
M1
CN
LEV1
CN
LEV2
CN
LEV3
CN
005
CN
AC
CN
002
CN
001
CN
001
CN
002
CN
006
CN
203
CN
204
CN
401
CN
103
CN
101
CN
518
CN
512
CN
513
CN
201
CN
003
CN
101
CN
003
CN50
1CN
502(
Red)
CN50
4(Ye
llow)
CN50
6(Bl
ue)
CN50
5
CN51
0
CN50
3(Bl
ue)
CN50
8(Re
d)
CN50
9(Bl
ue)
CN51
1(Re
d)
NTB01
L
(Red
)(R
ed)
(Yel
low
)(Y
ello
w)
(Red
)(R
ed)
(Yel
low
)(Y
ello
w)
(Red
)(R
ed)
MM
MM
MM
MM
CN
202
32
13
21
45
CN
201
43
21
32
1
CN
203 5
CN
204
43
21
32
15
43
21
32
1
CN
205 5
CN
206
43
21
32
15
43
21
32
15
43
21
32
15
43
21
32
15
CN
207
CN
208
CN
210
CN
209
CN
212
CN
211
CN
214
CN
213
CN
216
CN
215
VB3a
VB3b
VB3c
VB3d
VB3e
VB3f
VB3g
VB3h
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
(Sym
bol e
xpla
natio
n)
LEV1
~3
TH11
~16,T
H32~
35,
TH31
a~h
ACL
PS1,
PS3
Pres
sure
sens
or
Sym
bol
Nam
eAC
reac
tor
Ther
mist
er se
nsor
Expa
nsion
valve
TB01
Term
inal b
lock
(for p
ower
sour
ce)
TB02
Term
inal b
lock
(for T
rans
miss
ion)
Fuse
AC2
50V
6.3A
FF0
01So
lenoid
valve
SV1
21S4
Ma,
21S4
Mb
4 wa
y valv
eW
P1,W
P2Pu
mpNa
me
Sym
bol
VB3a
~hVa
lve b
lock
FSFl
oat s
witch
(Blu
e)
12
3Z CN
514
ZFu
nctio
n sett
ing co
nnec
torSW
3SW
4
SW5
1234
5678
9
ON
1012
3456
7891
0
ON
1234
5678
ON
3
. The
wiri
ngs
to T
B01
and
TB
02 s
how
n in
dot
ted
line
are
field
wor
k.
CMB-WM108V-AA
0000004671.BOOK 11 ページ 2018年3月13日 火曜日 午前11時9分
4. ELECTRICAL WIRING DIAGRAMS Indoor units
MEES17K102
HB
C c
on
tro
ller
12EIo-1
NO
TE:1
.TB0
2 is
tran
smis
sion
term
inal
blo
ck.
Nev
er c
onne
ct p
ower
line
to it
.2.
The
initia
l set
val
ues
of s
witc
h on
Con
trol B
oard
are
as
follo
ws.
SW1:
0SW
2:0
LED
1
SW1
SW2
SWP2
SWP1
SWP3
110
DSA
001
(Blu
e)(Y
ello
w)
(Gre
en)
(Red
)
(Gre
en)
(Gre
en)
(Blu
e)
(Blu
e)
(Blu
e)
(Yel
low
)
(Red
)
(Red
)
(Blu
e)
(Red
)(R
ed)
(Red
)
(Red
)
(Red
)
F001
250V
AC6.
3A F
TO N
EXT
IND
OO
R U
NIT
PULL
BO
X
FUSE
(16A
)BR
EAKE
R(1
6A)
POW
ER S
UPP
LY~2
20V-
240V
50H
z/60
Hz
Indo
or/o
utdo
orTr
ansm
issi
on L
ine
t°t° t° t°t°t°t° t° t°t° t°t° t°t°t°t° t°t° t°t° t° t°t°t° t°t°
MMM
UU
X002
X006
X003
ACL
SV1
21S4
Mb
21S4
Ma
ZNR0
01
L001
ZNR0
02
C004
C006
C003
C005
C002
C007
LEV1
LEV2
LEV3
WP1
WP2
1 3
1
7
2
6
3
5
4
4
5
3
6
2
1
2
32
1
7
1
2
1
11
1
1
1
11
1
1
2
22
2
2
3
33
3
3
22
2
2
33
3
3
4
4
11
24
45
56
6
PS1
PS3
FSZ
TH12
TH11
TH31
c
TH31
m
TH31
b
TH31
a
TH31
f
TH31
d
TH31
n
TH13
TH31
p
TH14
TH31
o
TH31
e
TH31
h
TH31
g
TH34
TH31
i
TH31
j
TH35
TH31
k
TH31
l
TH16
TH33
TH15
TH32
66
65
55
44
43
33
22
21
11
Con
trol B
oard
Pow
er B
oard
111
1 1
11
1
3
1111 222
2 2
22
2
1
2222 333
3 3
33
3
3333 444
4 4
55
4
4444 555
5 5
77
5
55 666
6 67 7
99
6
6531
13
55
37
1
S(SH
IELD
)TB02
M2
M1
CN
LEV1
CN
LEV2
CN
LEV3
CN
005
CN
AC
CN
002
CN
001
CN
001
CN
002
CN
006
CN
203
CN
204
CN
401
CN
103
CN
101
CN
518
CN
507
CN
512
CN
515
CN
516
CN
513
CN
514
CN
201
CN
003
CN
101
CN
003
CN
501
CN
502(
Red
)
CN
504(
Yello
w)
CN
506(
Blue
)
CN
505
CN
510
CN
503(
Blue
)
CN
508(
Red
)
CN
509(
Blue
)
CN
511(
Red
)
NTB01
L
X
(Red
)(R
ed)
(Yel
low
)(Y
ello
w)
(Red
)(R
ed)
(Yel
low
)(Y
ello
w)
(Red
)(Y
ello
w)
(Red
)(Y
ello
w)
MM
MM
MM
MM
MM
MM
MM
MM
CN
202 3
21
87
65
43
2
32
14
5C
N20
1
1
43
21
32
1
87
65
43
21
CN
203
5
CN
204
43
21
32
1
87
65
43
21
54
32
13
21
87
65
43
21
CN
205
5
CN
206
44
33
22
11
33
22
11
55
44
33
22
11
33
22
11
55
43
21
32
1
87
65
43
21
54
32
13
21
87
65
43
21
5
CN
801
CN
802(
Red
)C
N80
3(Ye
llow
)C
N80
6(Ye
llow
)C
N80
5(R
ed)
CN
804 CN
207
CN
208
CN
210
CN
209
CN
212
CN
211
CN
214
CN
220
CN
213
CN
219
CN
216
CN
218
CN
215
CN
217
VB3k
VB3a
VB3b
VB3l
VB3c
VB3m
VB3d
VB3n
VB3e
VB3o
VB3f
VB3p
VB3g
VB3j
VB3h
VB3i
Det
ail o
f X s
ectio
n
LD1:
CPU
in
ope
ratio
n
LD1:
CPU
in
ope
ratio
nLD
1:C
PU in
o
pera
tion
LD1:
CPU
in
ope
ratio
nLD
1:C
PU in
o
pera
tion
LD1:
CPU
in
ope
ratio
nLD
1:C
PU in
o
pera
tion
LD1:
CPU
in
ope
ratio
nLD
1:C
PU in
o
pera
tion
LD1:
CPU
in
ope
ratio
n
LD1:
CPU
in
ope
ratio
n
LD1:
CPU
in
ope
ratio
nLD
1:C
PU in
o
pera
tion
LD1:
CPU
in
ope
ratio
nLD
1:C
PU in
o
pera
tion
LD1:
CPU
in
ope
ratio
n
(Sym
bol e
xpla
natio
n)
LEV1
~3
TH11
~16,
TH32
~35,
TH31
a~p
ACL
PS1,
PS3
Pres
sure
sen
sor
Sym
bol
Nam
eAC
reac
tor
Ther
mis
ter s
enso
r
Expa
nsio
n va
lve
TB01
Term
inal
blo
ck(fo
r pow
er s
ourc
e)
TB02
Term
inal
blo
ck(fo
r Tra
nsm
issi
on)
Fuse
AC
250V
6.3
A F
F001
Sole
noid
val
veSV
1
21S4
Ma,
21S4
Mb
4 w
ay v
alve
WP1
,WP2
Pum
p
Nam
eSy
mbo
l
VB3a
~pVa
lve
bloc
k
ZFSFu
nctio
n se
tting
con
nect
orFl
oat s
witc
h
SW3
SW4
SW5
12
34
56
78
9
ON
12
34
56
78
9
ON
12
34
56
78
O
3.Th
e w
iring
s to
TB0
1 an
d TB
02 s
how
n in
dotte
d lin
e ar
e fie
ld w
ork.
1010
CMB-WM1016V-AA
0000004671.BOOK 12 ページ 2018年3月13日 火曜日 午前11時9分
4. ELECTRICAL WIRING DIAGRAMS Indoor units
MEES17K102
HB
C co
ntro
ller
13EIo-1
NO
TE:1
. TB
02 is
tran
smis
sion
term
inal
blo
ck.
Nev
er c
onne
ct p
ower
line
to it
.
2. T
he in
itial
set
val
ues
of s
witc
h on
C
ontro
l Boa
rd a
re a
s fo
llow
s.
SW
1:0
S
W2:
0
Det
ail o
f X s
ectio
n
LED
1 SW
1S
W2
SWP2
SWP1
SWP3
110
X
DS
A00
1
(Red
)
(Gre
en)
(Gre
en)
(Red
)
(Blu
e)(R
ed)
F001
250V
AC
6.3A
F
TO N
EXT
IND
OO
R U
NIT
PULL
BO
X
FUSE
(16A
)BR
EAKE
R(1
6A)PO
WER
SU
PPLY
~220
V-24
0V 5
0Hz/
60H
z
Indo
or/o
utdo
orTr
ansm
issi
on L
ine
t°t°t°t° t°t°t°t°t°t°
UU
ZNR0
01
L001
ZNR0
02
C004
C006
C003
C005
C002
C007
1
2
32
1
2
11
23
4
11
2
FS
TH31
c
TH31
b
TH31
a
TH31
f
TH31
d
TH31
e
TH31
hTH
31g
TH33
TH32
Con
trol B
oard
Pow
er B
oard
1
1
3
111
2
2
1
222
3
3
333
4
4
444
5
5
56
6
13
55
37
1
S(SH
IELD
)TB02
M2
M1
CN
005
CN
AC
CN
002
CN
001
CN
401
CN
103
CN
101
CN
518
CN
101
CN50
4(Ye
llow)
CN51
0
CN50
3(Bl
ue)
CN50
8(Re
d)
CN50
9(Bl
ue)
NTB01
L
(Red
)(R
ed)
(Yel
low
)(Y
ello
w)
(Red
)(R
ed)
(Yel
low
)(Y
ello
w)
(Red
)(R
ed)
MM
MM
MM
MM
CN
202
32
13
21
45
CN
201
43
21
32
1
CN
203 5
CN
204
43
21
32
15
43
21
32
1
CN
205 5
CN
206
43
21
32
15
43
21
32
15
43
21
32
15
43
21
32
15
CN
207
CN
208
CN
210
CN
209
CN
212
CN
211
CN
214
CN
213
CN
216
CN
215
VB3a
VB3b
VB3c
VB3d
VB3e
VB3f
VB3g
VB3h
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
LD
1:C
PU in
o
pera
tion
(Sym
bol e
xpla
natio
n)
TH31
a~h,T
H32,T
H33
Symb
olNa
meTh
ermist
er se
nsor
TB01
Term
inal b
lock
(for p
ower
sourc
e)
TB02
Term
inal b
lock
(for T
ransm
ission
)Fu
se AC
250V
6.3A
FF0
01
VB3a
~hVa
lve bl
ock
FSFlo
at sw
itch
ZFu
nctio
n sett
ing co
nnec
tor
(Blu
e)
12
3Z
CN
514
SW
3S
W4
SW
5
1234
5678
910
1234
5678
910
ON
ON
1234
5678
ON
3
. The
wiri
ngs
to T
B01
and
TB
02 s
how
n in
dot
ted
line
are
field
wor
k.
CMB-WM108V-AB
0000004671.BOOK 13 ページ 2018年3月13日 火曜日 午前11時9分
4. ELECTRICAL WIRING DIAGRAMS Indoor units
MEES17K102
HB
C c
on
tro
ller
14EIo-1
NO
TE:1
.TB0
2 is
tran
smis
sion
term
inal
blo
ck.
Nev
er c
onne
ct p
ower
line
to it
.2.
The
initia
l set
val
ueso
f sw
itch
onC
ontro
lBoa
rdar
e as
follo
ws.
SW1:
0SW
2:0
Det
ail o
f X s
ectio
n
LED1
SW1
SW2
SWP2
SWP1
SWP3
110
X
DSA0
01
(Red
)
(Gre
en)
(Gre
en)
(Blue
)
(Red
)
(Blue
)
(Red
)
(Red
)
F001
250V
AC6.
3A F
TO N
EXT
INDO
OR
UNIT
PULL
BO
X
FUSE
(16A
)BR
EAKE
R(16
A)POW
ER S
UPPL
Y~2
20V-
240V
50H
z/60H
z
Indo
or/o
utdo
orTr
ansm
ission
Line
t° t°t°t°t° t° t° t° t°t°t°t° t° t°t° t°t°t°
UU
ZNR0
01
L001
ZNR0
02
C004
C006
C003
C005
C002
C007
1
2
32
1
2
11
11
11
222
333
2
2
3
3
4
4
11
2
FSZ
TH31
c
TH31
m
TH31
b
TH31
a
TH31
f
TH31
d
TH31
n
TH31
pTH
31o
TH31
e
TH31
hTH
31g
TH31
iTH
31j
TH31
kTH
31l
TH33
TH32
Cont
rol B
oard
Powe
r Boa
rd
1
1 1
1
3
111
2
2 2
2
1
222
3
3 3
3
333
4
4 4
4
444
5
5 5
5
56
6 67 7 6
13
55
37
1
S(SH
IELD
)TB02
M2
M1
CN00
5CN
AC
CN00
2
CN00
1
CN40
1CN
103
CN10
1
CN51
8
CN50
7CN
515
CN51
6
CN51
4
CN10
1
CN50
4(Ye
llow)
CN50
6(Bl
ue)
CN50
5
CN51
0
CN50
3(Blue
)
CN50
8(Red
)
CN50
9(Blue
)
NTB01
L
(Red
)(R
ed)
(Yell
ow)
(Yell
ow)
(Red
)(R
ed)
(Yell
ow)
(Yell
ow)
(Red
)(Y
ellow
)(R
ed)
(Yell
ow)
MM
MM
MM
MM
MM
MM
MM
MM
CN20
23
21
87
65
43
2
32
14
5CN
201
1
43
21
32
1
87
65
43
21
CN20
3 5
CN20
44
32
13
21
87
65
43
21
54
32
13
21
87
65
43
21
CN20
5 5
CN20
64
43
32
21
13
32
21
15
54
43
32
21
13
32
21
15
54
32
13
21
87
65
43
21
54
32
13
21
87
65
43
21
5
CN80
1CN
802(
Red)
CN80
3(Ye
llow)
CN80
6(Ye
llow)
CN80
5(Re
d)CN
804 CN
207
CN20
8CN
210
CN20
9CN
212
CN21
1CN
214
CN22
0CN
213
CN21
9CN
216
CN21
8CN
215
CN21
7
VB3k
VB3a
VB3b
VB3l
VB3c
VB3m
VB3d
VB3n
VB3e
VB3o
VB3f
VB3p
VB3g
VB3j
VB3h
VB3i
LD1:
CPU
in
ope
ratio
n
LD1:
CPU
in
ope
ratio
nLD
1:CP
U in
o
pera
tion
LD1:
CPU
in
ope
ratio
nLD
1:CP
U in
o
pera
tion
LD1:
CPU
in
ope
ratio
nLD
1:CP
U in
o
pera
tion
LD1:
CPU
in
ope
ratio
nLD
1:CP
U in
o
pera
tion
LD1:
CPU
in
ope
ratio
n
LD1:
CPU
in
ope
ratio
n
LD1:
CPU
in
ope
ratio
nLD
1:CP
U in
o
pera
tion
LD1:
CPU
in
ope
ratio
nLD
1:CP
U in
o
pera
tion
LD1:
CPU
in
ope
ratio
n
(Sym
bol e
xpla
natio
n)
TH31
a~p,
TH32
,TH3
3Sy
mbo
lNa
me
Ther
mist
er se
nsor
TB01
Term
inal b
lock
(for p
ower
sour
ce)
TB02
Term
inal b
lock
(for T
rans
miss
ion)
Fuse
AC2
50V
6.3A
FF0
01
VB3a
~pVa
lve b
lock
ZFSFu
nctio
n se
tting
conn
ecto
rFl
oat s
witch
SW3
SW4
SW5
1234
5678
910
10
ON
1234
5678
910
ON
1234
5678
ON
3.Th
e w
iring
s to
TB0
1 an
d TB
02 s
how
n in
dotte
d lin
e ar
e fie
ld w
ork.
CMB-WM1016V-AB
0000004671.BOOK 14 ページ 2018年3月13日 火曜日 午前11時9分
5. SOUND LEVELS Indoor units
MEES17K102
HB
C co
ntro
ller
15EIo-1
5. SOUND LEVELS5-1. Sound levels(Measured point)
5-2. NC curves
* Measured in anechoic room.
CMB-WM108V-AACMB-WM1016V-AA
1.5m
Measurement location
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
NC-60
NC-50
Oct
ave
band
pre
ssur
e le
vel (
dB) 0
dB=2
0μP
a
Approximate minimumaudible limit oncontinuous noise
NC-40
NC-30
NC-20
63 125 250 500 1k 2k 4k 8kOctave band center frequencies (Hz)
CMB-WM108V-AA,CMB-WM1016V-AA
Power Source: 230V, 50Hz
0000004671.BOOK 15 ページ 2018年3月13日 火曜日 午前11時9分
6. ELECTRICAL CHARACTERISTICS Indoor units
MEES17K102
HB
C c
on
tro
ller
16EIo-1
6. ELECTRICAL CHARACTERISTICS
Symbols: MCA: Max. Circuit Amps, MFA: Max. Fuse Amps, RLA: Rated Load Amps
HBC controllerPower supply
RLA(A)Hz Volts Range+-10% MCA(A) MFA(A)
CMB-WM108V-AACMB-WM1016V-AA
50/60
220Max.: 264VMin.: 198V
3.49 15
2.89
230 2.83
240 2.79
CMB-WM108V-ABCMB-WM1016V-AB
50/60
220Max.: 264VMin.: 198V
0.06 15
0.05
230 0.05
240 0.05
0000004671.BOOK 16 ページ 2018年3月13日 火曜日 午前11時9分
MEES17K102New publication effective Mar. 2018
Specifications subject to change without notice
WarningDo not use refrigerant other than the type indicated in the manuals provided with the unit and on the nameplate.- Doing so may cause the unit or pipes to burst, or result in explosion or fire during use, repair, or at the time of disposal of the unit.- It may also be in violation of applicable laws.- MITSUBISHI ELECTRIC CORPORATION cannot be held responsible for malfunctions or accidents resulting from the use of the wrong
type of refrigerant.Our air conditioning equipment and heat pumps contain a fluorinated greenhouse gas, R410A/R32.
■
■