Model B2 19-inch Rack Static Transfer Switch

Upload: marvin-sampson

Post on 30-Dec-2015

29 views

Category:

Documents


0 download

DESCRIPTION

Model  B2. 19-inch Rack Static Transfer Switch. Why choose a model B2 static transfer switch?. Increases power availability . Integrated maintenance bypass. True solid state . Input isolators. Rugged, reliable design . Fast, Intelligent transfers . One touch transfer. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Model  B2

Model B2

19-inch RackStatic Transfer Switch

Page 2: Model  B2

Why choose a model B2static transfer switch?

• Increases power availability.• Integrated maintenance bypass.• True solid state.• Input isolators.• Rugged, reliable design.• Fast, Intelligent transfers.• One touch transfer.• Hot socket field replaceable power module.• Available in both single and three Phase.• Built In LAN web server and HLI.• Available with either LCD or decal interface.• Supported current up to 63A.

Page 3: Model  B2

Features

• Fast, reliable switching• Transparent transfer – less than ¼ cycle.• Solid state devices are far superior to their electro-mechanical equivalents. • Triple redundant internal power sources.

Page 4: Model  B2

Features

• Real time monitoring• LCD mimic status.• Touch screen LCD shows input/output voltage and current.• Visual and audible alarm.• Ethernet web server.

Page 5: Model  B2

LCD Screen functions • Status.• Bypass .• Alarms.• Event list (200 events).• List of Variables.• Settings.• Ethernet options.

Liquid Crystal Display

Page 6: Model  B2

Decal interface •Simple mimic status.•Simple Load indicator LEDS.•Preference LEDS.•Visual and audible alarm.

`Alternative Display

Page 7: Model  B2

• Multiple communications options • From Ethernet (IEEE802.3 10BaseT)

• SNMP• MODBUS• HTTP - Web server• Email Alerts.

• 5 relay outputs.•Pin 10 to 12 General Alarm•Pin 6 to 8 RLY-O/P Not in Synch•Pin 2 to 4 RLY-O/P Overloaded•Pin 1 to 3 RLY-O/P ON A•Pin 5 to 14 RLY-O/P ON B

•2 control inputs.•Pin 13 to Pin 7 Remote Transfer to S1 •Pin 11 to Pin 7 Remote Transfer to S2

Features

Page 8: Model  B2

Ethernet functions • Status.• Event list (200 events).• List of Variables.• Control panel.• Settings panel.

LAN interface

Page 9: Model  B2

Features

• Programmable logic control• Fast internal communication.• All variables are easily set in software.• Constantly monitors for alarm conditions.• Intelligent transfers.

Page 10: Model  B2

Features

• Flexible configurations• Screw Cage terminal (Up to 25mm2) for Input/output.• Hot socket field replaceable power module.

Page 11: Model  B2

Width: 483mm, 19”Height: 88mm, 3.5”Depth: 520mm, 20.5”Weight (typical): 15Kg, 33 lbs

Weight and Dimensions

Page 12: Model  B2

SpecificationSpecification

Type 1-pole / 1-phase

2-pole / 1-phase

3-pole / 3-phase

4-pole / 3-phase

Current Rating 32A 63A

Nominal Voltage 110V to 415V +- 20%

Fault Current 2kA for 20ms, 100A Fused

Frequency 50 / 60Hz (auto detection)

Power Factor No Limit

Crest Factor 3.5:1

Overload Capacity

100A for 30 sec.400A for 1 sec.

2,000A for 20 ms.