Computer Recommendations
• 750 MHz Pentium III or Better• 64 Meg SRAM• 40 Gig Hard Drive• 1024 x 768 graphics• CD Writer• USB Port• Standard RS-232 (COM port)• Windows 2000, XP or NT
![Page 3: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/3.jpg)
IES Software
Main Software Window
![Page 4: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/4.jpg)
Model 64 Pin Layout
![Page 5: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/5.jpg)
Model 64 Interface Boxes
Feedback Test Plug for Small Interface Box
Small Interface BoxRegular Interface Box
![Page 6: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/6.jpg)
Small Interface Box Connector
Dale MMP22G-11027L (Male)
Pin A – External Power (Orange)
Pin B – n.c.
Pin C – Ground (Brown)
Pin D – n.c.
Pin E – RX (Gray)
Pin F – Ground (Brown)
Pin H – External Power (Orange)
Pin J – RX (Gray)
Pin K – TX (Purple)
Pin L – n.c.
Pin M – TX (Purple)
![Page 7: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/7.jpg)
Direct Computer to Recorder Interface
The recorder can be directly connected to the RS-232 port of a computer. Only a DB-9 Female Connector and three wires, are required.
DB-9 Recorder
Pin 2 - TXPin 3 - RXPin 5 - Ground
![Page 8: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/8.jpg)
Sensor – Recorder Interface• To increase the odds of collecting data in harsh environments,
care must be taken to prevent sensor wire breakage
• Small sensor wires are connected to an interface board and epoxy is used to prevent wire movement.
• Interface boards allow easy sensor replacement and protects the recorder solder pads
![Page 9: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/9.jpg)
Sensor – Recorder Interface• The sensor cable goes through the strain relief hole on the
interface board, and the shield is soldered to the board.
![Page 10: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/10.jpg)
Sensor – Recorder Interface• The small sensor wires can be carefully stripped with a
soldering iron and a flat surface.
![Page 11: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/11.jpg)
Sensor – Recorder Interface• The wires are carefully soldered to the interface board.
Usually, IN+ is Green, IN- is White, Vref is Red, and Ground is Black.
![Page 12: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/12.jpg)
Sensor – Recorder Interface• After the wires are soldered, use epoxy to stabilize the wires to
prevent breakage.
![Page 13: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/13.jpg)
Sensor – Recorder Interface• Use resistor leads to connect the interface board to the
recorder.
![Page 14: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/14.jpg)
Sensor – Recorder Interface• Important: Use Kapton Tape between the interface board and
the recorder to prevent the solder pads from sticking to each other. This will allow easy removal of the interface board.
![Page 15: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/15.jpg)
Sensor – Recorder Interface• Align the interface board with the recorder and solder the feed
through wires to the board. Be sure the round and square holes match up.
![Page 16: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/16.jpg)
Sensor – Recorder Interface• Sensor Balancing (if required).
– Do not cut the feed through wires until you have balanced the sensor.– To balance the sensor, first program the recorder channel for maximum
Gain and set the Bias to 128. Put the recorder in STANDBY or “Battery Test” Mode, and go to the “View: Recorder Voltages” and monitor the analog voltage output for that channel.
– Connect a resistor decade box to either IN+ and ground OR IN- and ground, using the leads extending out of the interface board on the recorder. One or the other combination will allow you to balance the sensor. Adjust the resistance until the analog output of the recorder channel is approximately bit 128 (~1.7 volts). This value is the resistor you will solder on the termination board. Be sure to use 1% ceramic SM resistors.
– After you install the balance resistor, epoxy it in place, and your sensor is now balanced.
![Page 17: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/17.jpg)
Sensor – Recorder Interface• Sensor Balancing.
– Leave the feed through wires in place and connect the resistor decade box. With the channel Gain set to maximum and the Bias set to bit 128, put the recorder in the “STANDBY” mode.
![Page 18: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/18.jpg)
Sensor – Recorder Interface• Sensor Balancing.
– Adjust the decade box until the analog Vout is in the middle (~Bit 128). (View: Recorder Voltages) Try IN+/ground or IN-/ground.
![Page 19: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/19.jpg)
Sensor – Recorder Interface• Sensor Balancing.
– Install the closest 1%, ceramic SM resistor that matches the decade box. (If a resistor is needed)
![Page 20: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/20.jpg)
Sensor – Recorder Interface• Sensor Balancing.
– Epoxy the balance resistor.
![Page 21: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/21.jpg)
Recorder Operation Modes
![Page 22: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/22.jpg)
Recorder Operating Modes
• “Sleeping”• “Standby” (Battery Test)• “Recording Data”
![Page 23: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/23.jpg)
Recorder Operating Modes• “Sleeping”
– Recorder is in a low power mode and is NOT recording data. The sensors are OFF. Any data in memory is maintained as long as there is power connected to the Recorder.
– Draws 10 – 15 mA when connected to the computer.
– Draws ~0.6 mA when NOT connected to the computer.
![Page 24: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/24.jpg)
Recorder Operating Modes
Sleeping…
![Page 25: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/25.jpg)
Recorder Operating Modes• “Standby”
– Recorder and sensors are fully powered up, but the Recorder is NOT recording data.
– Draws 40 – 100 mA, depending on the number of channels and sensors connected to the Recorder.
– The mode is typically used to test the battery and sensors for proper voltages.
![Page 26: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/26.jpg)
Recorder Operating Modes
Standby…
![Page 27: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/27.jpg)
Recorder Operating Modes• “Recording Data”
– Recorder and sensors are fully powered up, and the Recorder is recording data in the “SLOW SPEED” sampling mode.
– Draws 35 – 100 mA, depending on the number of channels and sensors connected to the Recorder.
– When the Recorder is disconnected from the computer, it will continue recording data.
NOTE: The Recorder cannot be triggered into “FAST Speed” while it is connected to the computer.
![Page 28: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/28.jpg)
Recorder Operating ModesRecording Data…
![Page 29: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/29.jpg)
Recorder Sampling Speeds
![Page 30: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/30.jpg)
Recorder Sampling Speeds
• Multi-Speed Data Recording Modes.– Fast Speed
• 115,000 data points/second– Intermediate Speed
• 115 data points/second toto 14,700 data points/second– Slow Speed
• One data point every 10 seconds toto 14 data points/second
“Recorder Settings” Menu
Multiple recording modes can be selected
![Page 31: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/31.jpg)
Recorder Sampling Speeds• “SLOW Sampling Speed”
– When the Recorder starts recording data, it begins storing data at the “Slow Speed” sampling rate.
– The ONLY time the Recorder does NOT start in the “Slow Speed” is if the “Fast Speed on Startup” has been enabled.
• “FAST Sampling Speed”– When an “Internal Auto Trigger” occurs (i.e. the pressure exceeds
the programmed threshold), the Recorder begins storing data at the “FAST Speed” sampling rate (115,000 data points per second).
![Page 32: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/32.jpg)
Recorder Sampling Speeds• “INTERMEDIATE Sampling Speed”
– After the “FAST Speed” sampling window has completed, the Recorder will begin storing data at the “INTERMEDIATE Speed” sampling rate (if this mode is enabled).
– After the “INTERMEDIATE Speed” sampling window has completed, the Recorder go back to storing data at the “SLOW Speed” sampling rate.
– NOTE: The Recorder might go back into the “FAST Speed” mode before it return to the “SLOW Speed” mode, if another “Auto Trigger” occurs while in the “INTERMEDIATE Speed” mode.
![Page 33: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/33.jpg)
Auto “LOW BATTERY” Shutdown
![Page 34: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/34.jpg)
Auto “LOW BATTERY” Shutdown
• When the Recorder is “Recording Data” and the battery voltage goes below a safe operating voltage (typ. 4.5 volts), the Recorder will automatically stop recording data and go to SLEEP (0.5 milliamps).
• This feature ensures that data is not lost if the Recorder cannot be recovered in a timely manner. In the SLEEP mode, the data can be maintained in memory for up to 30 days (or longer depending on the batteries).
NOTE: ALWAYS use an External 9 volt battery for backup power when you connect the computer to the recorder.
![Page 35: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/35.jpg)
Recorder Software Features
![Page 36: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/36.jpg)
Software Preferences
Selected in the Main Software Window under “LINK”
Allows you to set certain defaults when the software starts.
![Page 37: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/37.jpg)
Test Sensors
Selected in the Main Software Window under “Control”
Tests the sensors and internal voltages of the recorder. You can perform this test on your own.
![Page 38: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/38.jpg)
Voltage Monitoring
Monitors Internal and Sensor Input Voltages.
Selected in the Main Software Window, under “View”
![Page 39: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/39.jpg)
Job Report
Selected in the Main Software Window, under “Edit”
Allows you to to store information about a job or test directly into the Recorder or data file.
![Page 40: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/40.jpg)
Edit Recorder Channel DataContains the sensor calibration information for each channel, and general user
information.
Selected in the Main Software Window, under “Edit”
![Page 41: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/41.jpg)
Recorder Settings Menu
Selected in the Main Software Window, under “Edit”
![Page 42: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/42.jpg)
Displaying Recorder Data
Selected in the Main Software Window, under “View”
![Page 43: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/43.jpg)
View Test Data
Selected in the “View Recorder Data” Window, under “View”
Shows data about the job and the data you downloaded.
![Page 44: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/44.jpg)
Convert Data to ASCII FileAllows you to exporting the Recorder data to an ASCII file for use in Windows Excel
or other programs.
Selected in the “View Recorder Data” Window, under “File”
![Page 45: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/45.jpg)
View the Recorder Battery Voltage and Recorder Temperature EEPROM Data.
Battery Data
Select the “Display : Slow Speed Data”, and then display “Battery” and “Temperature” to view this data (dotted lines).
Temperature Data
Selected in the “View Recorder Data” Window
![Page 46: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/46.jpg)
Programming the Recorder Settings
![Page 47: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/47.jpg)
Changing the Recorder Settings
• To program the Recorder Options, go to the “Recorder Settings” menu
![Page 48: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/48.jpg)
Recorder Settings Menu
![Page 49: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/49.jpg)
To EDIT the recorder “Settings”, FIRST go to the “Edit” pull down menu and select “Recorder Settings”
![Page 50: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/50.jpg)
Second, you must enter the password “IES”. Now you can EDIT the Recorder Settings.
![Page 51: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/51.jpg)
Recording Speed Options
• Data Recording Modes.– “Slow Speed ONLY”– “Slow -> Fast -> Slow Speed”– “Slow -> Fast Speed”– “Multi-Speed”
![Page 52: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/52.jpg)
Recording Speed Options
• Data Recording Modes.– Fast Speed
• 115,000 data points/second– Intermediate Speed
• 115 data points/second toto 14,700 data points/second– Slow Speed
• One data point every 10 seconds toto 14 data points/second
“Recorder Settings” Menu
Multiple recording modes can be selected
![Page 53: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/53.jpg)
Recording Speed Options
• Slow Speed Data Recording.– Records data from one data point every 10 seconds up toup to
14 data points/second– When not in “Fast” or “Intermediate” recording speeds, the
data is sampled at “Slow” Speed
“Recorder Settings” Menu
“Slow” speed sampling rate can be selected
(8 values)
![Page 54: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/54.jpg)
5 10 15 20 25 30 35 40 45 50 55 60 65Time - minutes
0
1
2
3
4
5
6
7
8
9
10Pr
essu
re -
MPa
0
5
10
15
20
25
30
35
40
45
Tem
pera
ture
Penn WestSlow speed data
file: 684a.grf
CCLcorrelation
ignition --
pressure
temperature
“Slow Speed” Data
Slow Speed Data(2 data points/second)
Fast and Intermediate Speed
Data
![Page 55: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/55.jpg)
Recording Options
• Fast Speed Data Recording.– Changes sampling rate to Fast speed (115,000 data
points/second) when pressure* exceeds programmed Trigger Level
“Recorder Settings” Menu
Trigger Level
Trigger Threshold“Actual Value” or “Above Static”Trigger Channel
* Or other analog channels
![Page 56: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/56.jpg)
Recording Options
• Fast Speed Data Recording.– After the trigger level has been reached, and the Recorder
records at Fast Speed for a “preset” time window (10 millisecand greater, depending on memory available)
“Recorder Settings” Menu
Fast Speed Time Window
![Page 57: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/57.jpg)
“Fast Speed” Data(115,000 data points/second)
-0.001 0.000 0.001 0.002 0.003 0.004 0.005 0.006 0.007 0.008 0.009 0.010Time seconds
0
5
10
15
20
25
30
35
40
45
50
Pres
sure
- M
PaKey West
High speed pressure data
file 686b1perf -gun
- propellant burn
max. verticalstress ~36 MPa -
max. horizontal stress ~27 MPa?
Static Pressure of 1500 psi
Trigger Point
Trigger Level of 2500 psi above Static Pressure
4000 psi
Fast Speed Time Window
40 millisec of Pre-Trigger Fast Speed Data is saved
![Page 58: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/58.jpg)
Recording Options• Intermediate Speed Data Recording.
– After the Recorder is done recording at “Fast” speed, it starts collecting data at a “Intermediate” speed, at a “preset”sampling rate and time window (depending on memory available), ONLY IF this MODE (Multi-Speed Speed) has been enabled.
“Recorder Settings” Menu
Intermediate Speed Time Window (in seconds)
Intermediate Sampling Speed (8 values)
![Page 59: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/59.jpg)
“Intermediate Speed” Data
0 1 2 3 4 5 6 7 8 9 10 11Time seconds
-6
-3
0
3
6
9
12
15
18
21
24
27
Pres
sure
- M
Pa
Penn West tool movement/pressure
file 684b1
tool movement - meters
*
Intermediate Speed Data
(1000 data points/second)
Tool Movement Tool Pressure
Fast Speed Data
Intermediate Speed Time Window (in seconds)
![Page 60: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/60.jpg)
Other Features
• Programmable Features.– Over 130,000 pressure* Range Combinations.– Automatic Sensor Balancing at “Start” – Automatic Sensor Balancing “During the Test”
• Used for sensors that are sensitive to drifting during to temperature. Mainly High G Accelerometers
– Automatic Sensor Testing
* Or other analog channels
![Page 61: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/61.jpg)
Sensor Balance
Sensor Test / Display Data
Sensor Range
![Page 62: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/62.jpg)
Programming New Settings into the Recorder
• Saving any changes to the Recorder
![Page 63: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/63.jpg)
“Starting” the Recorder to Collect Data
![Page 64: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/64.jpg)
Connecting Battery Power to the Recorder
• When power is first connected to the Recorder, a “Power Interruption”error will always occur. This is normal and indicates power has just been applied. NOTE: If this error occurs after data has been collected, it could indicate a battery problem occurred.
![Page 65: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/65.jpg)
Connecting Battery Power to the Recorder
• Clear the “Power Interruption” error with the “Clear Error Flags”
![Page 66: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/66.jpg)
“Start” Options
• Multiple “Start” Recording Data Options– Manual Start– Start on “Power Up”– Start after Delay– Auto Start – External Start (T1)
![Page 67: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/67.jpg)
“Start” Options• “Manual” Start
– Manually Starts recording data in the “Slow Speed Mode”.
![Page 68: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/68.jpg)
“Start” Options• Starting…
– When the recorder is Started, all data that is in memory will be erased…
![Page 69: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/69.jpg)
“Start” Options• Starting…
– The Recorder and Sensors (if enabled) is tested before the Recorder is Started.
![Page 70: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/70.jpg)
“Start” Options• Starting…
– If the Sensor Test fails for some reason, you still have the option to “Start” the recorder anyway…
![Page 71: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/71.jpg)
“Start” Options• Recording Data…
– If the Recorder is actually RECORDING DATA into memory (in the Slow Speed Mode), the main menu display will indicate this.
![Page 72: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/72.jpg)
“Start” Options• Other Ways to Start the Recorder…
– To enable other “START” options, go to the “Recorder Settings” menu
![Page 73: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/73.jpg)
Start / Stop Recording Options
![Page 74: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/74.jpg)
“Start” Options• “Power Up” Start
– Starts recording data when Recorder is powered up.
This will activate ONLY if “Checked”in the “Recorder Settings” Menu.
“Recorder Settings” Menu
![Page 75: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/75.jpg)
“Start” OptionsIf the “Power Up Start” is enabled and these new settings are saved to the
Recorder, the Recorder will automatically perform a Sensor Test.
![Page 76: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/76.jpg)
“Start” Options• “Power Up” Start
– When activated, the Main menu shows this feature is will occur when the battery/power is connected to the recorder.
NOTE: if the computer is connected to the recorder when battery / power is applied, the “Power Up” Start will not be activated.
![Page 77: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/77.jpg)
“Start” Options
• “Delay” Start– Recorder is enabled to “Start Recording Data” after the
programmed delay reaches zero. This count down only occurs while the Recorder is NOT connected to the computer.
Recorder will NOT start recording data until the count reaches zero
– Draws 8 – 10 mA when the Recorder is not connected to the computer, and while it is counting down.
![Page 78: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/78.jpg)
“Start” Options• “Delay” Start
– Start recording data after 1 to 255 hours (±30 minutes)– Draws 6 – 8 mAThis feature must be first, enabled in the “Recorder Settings” menu,
and second, “Started” in the “START/STOP” pull down menu.
Step #1Step #2
“Recorder Settings” Menu
![Page 79: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/79.jpg)
“Start” Options• “Delay” Start
– When the “Delay” Start feature is activated, the Main Menu will indicated this feature is enabled.
NOTE: The delay counter will not start until the computer is disconnected from the recorder.
![Page 80: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/80.jpg)
“Start” Options• “Auto” Start
– The Recorder is enabled to “Start Recording Data” after the actual sensor value (i.e.500 psi) exceeds the programmed threshold. This only can occur if the Recorder is NOT connected to the computer.
– In the “Low Power Mode”, the Recorder will “wake up” for one second, once every 5 minutes, to check the sensor (i.e. pressure) to see if it has exceed the programmed threshold. If not, the Recorder goes back to sleep for another 5 minutes. If the sensorvalue IS above the threshold, and remains above it for 5 – 10 minutes longer, the Recorder will start recording data .
– Draws ~0.7 mA when the Recorder is not connected to the computer, and it is checking the sensor.
![Page 81: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/81.jpg)
“Start” Options
• “Auto” Start– In the “Constant Monitor Mode”, the Recorder continuously monitors the
sensor (i.e. pressure) to see if it has exceed the programmed threshold. If the sensor value IS above the threshold, and remains above it for the programmed Threshold Time, the Recorder will start recording data .
– Draws 40 - 100 mA when the Recorder is not connected to the computer, and it is checking the sensor.
![Page 82: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/82.jpg)
“Start” Options
• “Auto” Start– Starts recording data when pressure* reaches a preset
value** (Entered in “Recorder Settings” menu)
5 10 15 20 25 30 35 40 45 50 55 60 65Time - minutes
0
1
2
3
4
5
6
7
8
9
10Pr
essu
re -
MPa
0
5
10
15
20
25
30
35
40
45
Tem
pera
ture
Penn WestSlow speed data
file: 684a.grf
CCLcorrelation
ignition --
pressure
temperature
Recorder Starts when pressure reaches 2300** psi
* Or other analog channels
![Page 83: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/83.jpg)
“Start” Options• “Auto” Start Options
– “Low Power Mode” (Advantage: Long Battery Life)• Checks Pressure* once every 5 minutes. (Draws only 0.5 milliamps of battery
power until the recorder starts.) • If Pressure* exceed the “Threshold”, the Pressure* must then remain above the
“Threshold” for the “Threshold Time”. If this happens, the recorder is then “Started”.
• If the Pressure* falls below the “Threshold” at any time, this Mode is reset and goes back to sleep for 5 more minutes.
“Recorder Settings” Menu * Or other analog channels
“Threshold”“MODE”
“Threshold Time”
![Page 84: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/84.jpg)
“Start” Options• “Auto” Start Options
– “Constant Monitor Mode” (Advantage: Quick Recorder “Start”)• Checks Pressure* continuously. (Draws up to 100 milliamps of battery power.)• If Pressure* exceed the “Threshold”, the Pressure* must then remain above the
“Threshold” for the “Threshold Time”. If this happens, the recorder is then “Started”.
• If the Pressure* falls below the “Threshold” at any time, the “Threshold Timer” is reset back to zero.
“Recorder Settings” Menu * Or other analog channels
“Threshold”“MODE”
“Threshold Time”
![Page 85: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/85.jpg)
“Start” Options• “Auto” Start Options
– “Delay before Auto Start”• If the “Delay before Auto Start” box is checked, AND the “Threshold” has been
exceeded for the “Threshold Time”, the recorder will not “Start” until after the “Delay Time” has timed out.
During the delay, the recorder draws 6 – 8 milliamps.
“Recorder Settings” Menu
* Or other analog channels
![Page 86: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/86.jpg)
“Start” Options• “Auto” Start
– This feature must FIRST be enabled in the “Recorder Settings” menu.
“Recorder Settings” Menu
* Or other analog channels
Step #1
![Page 87: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/87.jpg)
“Start” Options• “Auto” Start
After this feature is enabled in the “Recorder Settings” menu, it must be selected in the “START/STOP” pull down menu.
Step #2
* Or other analog channels
![Page 88: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/88.jpg)
“Start” Options• “Auto” Start
– When the “Delay” Start feature is activated, the Main Menu will indicated this feature is enabled.
NOTE: The delay counter will not start until the computer is disconnected from the recorder.
* Or other analog channels
![Page 89: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/89.jpg)
“Start” Options
• “External” Start (T1)Starts recording data when the External (T1) signal occurs (either External T1 or an internal G Switch in the recorder).
– “Bounces” (Internal G Switch or External T1 Signal)• If the selected “Number of Bounces” occurs within a certain
“Bounce Time Window”, the recorder will “Start” recording. – “Level Signal” (This feature might not be available)
• If the External (T1) remains HIGH for the “Min. Pulse Length” the recorder will “Start” recording.
– Draws ~0.7 mA when the Recorder is not connected to the computer, and it is checking the sensor.
![Page 90: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/90.jpg)
“Start” Options
• “External” Start (T1)– Starts recording data when the External (T1) signal occurs (either External T1 or an
internal G Switch in the recorder). This feature draws 0.5 milliamps.
![Page 91: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/91.jpg)
“Start” Options• “External” Start (T1)
– “Bounces” (Internal G Switch or External T1 Signal)• If the selected “Number of Bounces” occurs within a certain “Bounce Time
Window”, the recorder will “Start” recording. – “Level Signal” (This feature might not be available)
• If the External (T1) remains HIGH for the “Min. Pulse Length” the recorder will “Start” recording.
“Recorder Settings” Menu
“# of Bounces”“MODE”
“Bounce Time Window”
“Min. Pulse Length”
![Page 92: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/92.jpg)
“Start” Options• “External” Start (T1)
– “Quick START” (This feature might not be available)• If an “External Start (T1)” occurs, and this feature is enabled, the recorder will
instantly start recording data without warming up the analog channels or testing the sensors. Normal startup requires several seconds, whereas, this will start recording data instantly.
NOTE: The recorder will normally Start recording data in the FAST SPEED mode.
“Recorder Settings” Menu
![Page 93: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/93.jpg)
“Start” Options“External” Start (T1)
This feature must FIRST be enabled in the “Recorder Settings” menu.
“Recorder Settings” Menu
Step #1
![Page 94: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/94.jpg)
“Start” Options“External” Start (T1)
After this feature is enabled in the “Recorder Settings” menu, it must be selected in the “START/STOP” pull down menu.
Step #2
![Page 95: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/95.jpg)
“Start” Options“External” Start (T1)
– When the “External (T1)” Start feature is activated, the Main Menu will indicated this feature is enabled.
NOTE: The “External (T1)” will not be activated until the computer is disconnected from the recorder.
![Page 96: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/96.jpg)
“Stop” Options
• Manual Stop– The Recorder can be manually stopped when
connected to the computer.• Auto Stop
– When enabled in the Recorder Settings Menu, the recorder will stop recording data and go to “Sleep” after the Pressure* falls below a set Threshold.
* Or other analog channels
![Page 97: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/97.jpg)
“Stop” Options• “Manual” Stop
– Stops recording data.
![Page 98: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/98.jpg)
“Stop” Options• Stop…
– When the Recorder has Stopped recording data, the Main Menu Display will indicate this.
![Page 99: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/99.jpg)
“Stop” Options• “Auto” Stop
– Stops recording data when the pressure* falls below a preset value** (Entered in “Recorder Settings” menu)
5 10 15 20 25 30 35 40 45 50 55 60 65Time - minutes
0
1
2
3
4
5
6
7
8
9
10Pr
essu
re -
MPa
0
5
10
15
20
25
30
35
40
45
Tem
pera
ture
Penn WestSlow speed data
file: 684a.grf
CCLcorrelation
ignition --
pressure
temperature
Recorder Stops when pressure reaches 500** psi
* Or other analog channels
![Page 100: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/100.jpg)
“Stop” Options• “Auto” Stop
– The channel, pressure* threshold, and time must be selected, and enabled– Checks pressure* while in the “Slow Speed Mode” – If the pressure* falls below the threshold, for a “preset” time (in seconds), the Recorder
stops recording data, and goes to “Sleep”
NOTE: This feature is activated when it is selected in the “Recorder Settings” menu, and then programmed into the recorder.
This feature is enabled in the “Recorder Settings” menu
“Recorder Settings” Menu
* Or other analog channels
![Page 101: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/101.jpg)
Downloading the Data
![Page 102: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/102.jpg)
Downloading the Data• Always be sure an external 9 volt battery is connected to the interface
box before you connect the computer to the Recorder. This is to ensure you do not loose data if the internal Recorder battery is LOW.
![Page 103: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/103.jpg)
Downloading the Data• If the Recorder is still “Recording Data”, you must first “STOP” the
Recorder, before you can download the data.
![Page 104: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/104.jpg)
Downloading the Data• After the Recorder is in the “SLEEP” mode, you can download the data.
![Page 105: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/105.jpg)
Downloading the Data
• Download ALL Data– Downloads all the data in memory.
• Quick Download– Downloads only the “Valid Memory” data.
When collecting data, sometimes not all the memory is used to store the data, so the Recorder keeps track of how much data has actually been stored in memory. The Recorder will indicate how much data was stored into memory, and this download option downloads ONLY that data.
NOTE: If in doubt, use the “Download ALL Data” option.
![Page 106: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/106.jpg)
Downloading the Data• If a “Parity Error” occurs while downloading the data, just try
downloading the data again.
• The data can be downloaded as many times as you want to. The data remains in memory until EITHER you remove battery power OR you “START” the Recorder again.
![Page 107: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/107.jpg)
Displaying the Data
![Page 108: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/108.jpg)
Data Display Software
![Page 109: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/109.jpg)
Data Display Software
![Page 110: Model 64 Operation and Software - IES Global, Inciesglobalinc.com/.../IES-Model-64-Software-Guide.pdf · Software Preferences Selected in the Main Software ... Convert Data to ASCII](https://reader034.vdocuments.us/reader034/viewer/2022042201/5ea0f1e56945e7236d0907ad/html5/thumbnails/110.jpg)
Recorder Operation and Software
by Scott A. Ager