Page 1: MOBILE SPOT COOLER Service Manual€¦ · MOBILE SPOT COOLER Service Manual. Troubleshooting 1.Repair form Check 2.Confilm cause 3.Repair . Repair contents It is not out of cold air

MOBILE SPOT COOLER Service Manual

Page 2: MOBILE SPOT COOLER Service Manual€¦ · MOBILE SPOT COOLER Service Manual. Troubleshooting 1.Repair form Check 2.Confilm cause 3.Repair . Repair contents It is not out of cold air

Troubleshooting

1.Repair form Check

2.Confilm cause

3.Repair

Page 3: MOBILE SPOT COOLER Service Manual€¦ · MOBILE SPOT COOLER Service Manual. Troubleshooting 1.Repair form Check 2.Confilm cause 3.Repair . Repair contents It is not out of cold air

Repair contents

It is not out of cold air

Gas leak=Gas filling or Product exchange

Compressor trouble=Product exchange

Overload relay trouble=Overload relay exchange

Filter・condenser・evaporator dust =Clean up

Compressor condenser trouble=Compressor condenser exchange

Page 4: MOBILE SPOT COOLER Service Manual€¦ · MOBILE SPOT COOLER Service Manual. Troubleshooting 1.Repair form Check 2.Confilm cause 3.Repair . Repair contents It is not out of cold air

Fan motor trouble=Fan motor Exchange

Not working

Substrate trouble=Exchange

Power cord breakdown=Exchange

Switch trouble=Switch Exchange

Fan motor condenser trouble=Exchange

Repair contents

Page 5: MOBILE SPOT COOLER Service Manual€¦ · MOBILE SPOT COOLER Service Manual. Troubleshooting 1.Repair form Check 2.Confilm cause 3.Repair . Repair contents It is not out of cold air

Not swing

Swing parts or Swing belt trouble=Exchange

Swing switch trouble=Swing switch Exchange

Water leak Drain case=Drain case Clean up

Parts break Exchange

Swing motor trouble=Swing motor Exchange

Page 6: MOBILE SPOT COOLER Service Manual€¦ · MOBILE SPOT COOLER Service Manual. Troubleshooting 1.Repair form Check 2.Confilm cause 3.Repair . Repair contents It is not out of cold air

⑦ Complaint case No Content Answer

① Cold wind not out A cord is long ※No move compressor

② The whole room not cold It is a machine to cool at a spot

③ use it generator? Use a generator of the capacity of 4~5times

④ This machine is driven 24hour Possible

⑤ Electricity bill of one hour Electricity bill answer

⑥ Put the water No

⑦ Distribution duct None

⑧ Cool air temperature Environmental temperature=35℃ cool air temperature=about 25℃

⑨ Use timer Possible but after 3minutes of turning off

⑩ N407-TC & SAC-4500 only Stop the swing?

Choose the switch