mmi3g software update 22 presentation part two

2
Current MMI3G software update Contents  Te chnical innova t ions Elec t r onics Data memory entri es follo win g sof tw are upd ate in " 5F- Inform atio nselektron ik 1" (5F Information electronics 1) "SAECode 3623 Freischaltcode fehlerhaft" (SAECode 3623 — Incorrect release code) Cause: Re l ease co d e f or v o i ce d ata no t a v a i l a b l e . Func t i ona l l i m i t a t i on s: Th e v o i ce up d a t e f or t h e sp e ec h d i a l ogu e sy st e m c anno t b e p e r f orme d when switching to another language. If no language change is provided, the speech dialogue system continues to use the language set before the update. Procedure forexport market: - No cu st omer co m p la in t an d n o l an g u ag e c h an g e p r ov isi on Î put repair on hold - Cust o mer com p lain t u p o n lan g ua g e u p date Î replace control unit 1 for information electronics Procedure for German market: - Cr ea t e o bli g a t ion t o re p o r t v ia DISS The procedure will also be includ ed i n Guided Fault Finding.

Upload: eduardorojas007

Post on 14-Apr-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MMI3G Software Update 22 Presentation Part Two

7/30/2019 MMI3G Software Update 22 Presentation Part Two

http://slidepdf.com/reader/full/mmi3g-software-update-22-presentation-part-two 1/2

Current MMI3G software update

Contents

 Technical innovations Electronics

Data memory entries following software update in "5F-Informationselektronik 1" (5F

Information electronics 1)

"SAECode 3623 – Freischaltcode fehlerhaft" (SAECode 3623 — Incorrect release code)

Cause: Release code for voice data not available.

Functional limitations: The voice update for the speech dialogue system cannot be performed

when switching to another language.If no language change is provided, the speech dialogue systemcontinues to use the language set before the update.

Procedure for export market:

- No customer complaint and no language change provisionÎ

put repair on hold- Customer complaint upon language updateÎ replace control unit 1 for information electronics

Procedure for German market:

- Create obligation to report via DISS

The procedure will also be included in Guided Fault Finding.

Page 2: MMI3G Software Update 22 Presentation Part Two

7/30/2019 MMI3G Software Update 22 Presentation Part Two

http://slidepdf.com/reader/full/mmi3g-software-update-22-presentation-part-two 2/2

Current MMI3G software update

Contents

 Technical innovations Electronics

Back-up documentation following software update unsuccessful

Technical background:

¾ Control unit 1 for information electronics cannot restart automatically following update andparameterisation.

¾  The control unit no longer responds to requests from SVM.

¾ SVM generates the response "Hardware prüfen" (Test hardware) for all other MMI components.

Procedure:

1. The following appears in the MMI display after update:

2. Select "Dokumentation abbrechen" (Abort documentation).

3. The MMI automatically initiates a restart.

4. Wait until the MMI display is populated again.

5. Create back-up documentation with SVM code.