miracle booklet 1 - hvi.com.au

16
User Guide AC/DC 6 AC/DC 9 AC/DC 4 AC/DC 2 DC IP68 AC IP65

Upload: others

Post on 26-Jun-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: miracle booklet 1 - hvi.com.au

User Guide

AC/DC 6 AC/DC 9AC/DC 4AC/DC 2

DC IP68 AC IP65

Page 2: miracle booklet 1 - hvi.com.au

2

1

3

2

What else do I need?

What is in this package?

9V

1

1-9

Moiture sensor (Opional)

DC IP68 AC IP65

2

Page 3: miracle booklet 1 - hvi.com.au

3User Guide

Five different irrigation programs:

Selected days.Up to 4 start times.1 to 9 valves.Option of each valveseparately.

watering set pervalve (see page 13).

watering in secondsin a defined timewindow (see page 12).

Reliable Backup:Nonvolatile memory:All programs are saved (forever) in case of batteryfailure or replacement.Date and time are kept for1 minutes.

F e a t u r e s o f t h e M i r a c l e P l u s

Water Budget:200% to 10%in irrigation time.

Rain Delay putsprogram on hold tillresume operationas programmed.

Rain/MoistureSensor: anoptional sensorinput stopsirrigation whensoil is wet.

Special Features:

Page 4: miracle booklet 1 - hvi.com.au

4

Clock icon. Time and date are not complete.

Sensor is working andblocks irrigation.

Valve indicator.

Date indicator

MiraclePlus is off.MiraclePlus is on.

Manual Operation (program).

Manual Operation (valve).

Power failure

Page 5: miracle booklet 1 - hvi.com.au

5User Guide

Rain Delay. Enables adefined irrigation-free days.

Irrigation time as a percentage of value set (per program).

Warning! Check connections

Miracle Plus in operation.

Start time indicator.

Irrigation programe indicators.

Operationbuttons.

Caution-Battery low!

Battery out of powerand must be replaced.

Page 6: miracle booklet 1 - hvi.com.au

6

1 Installation 2

3A

B

C

4

9V

D

9

21

93

BlackCommon1 2 3MV

OrangeMV

Red1,2,3...9

ø=1mm240m

ø=0.5 mm150m

ø=1.5mm330m

DC

Page 7: miracle booklet 1 - hvi.com.au

7User Guide

Operation Instructions

programing:

Increase parametervalueNext parameterPrevious parameterDecrease parametervalue

Set Date and time

Set Date

ø=1mm2000m

ø=1.3 mm3500m

ø=0.8mm1250m

ø=1.1mm2500m

ø=1.5 mm5000m

AC

1 2 3 9MV

1,2,3...9 21

93

Page 8: miracle booklet 1 - hvi.com.au

8

Set 24 or 12 hour setting

MiraclePlusis now ready forprograming:

Set time

Page 9: miracle booklet 1 - hvi.com.au

Programs A, B & C:selected days with up to 4 start times,up to 9 valves, each operates separately(not simultaneously in the same program).For simultaneously operation, use same start timefor 2 or 3 different programs.First program will be A, followed by B and then C.For selecting active days: a) calendar days - (Sun, Mon,etc.) b) fixed interval days (e.g every 2nd day). with this option you may select odd or even dates (odd:1,3,5 even 2,4,6), and define non-irrigetion days.

User Guide

Active Days with Intervalpress the to define an interval (1 to 19).Active days will start tomorrow followed by(1 to 19) days you have defined, and thenthe next active day as a pattern.

Calendar Days as Active Days1.Press to select today as an active day.press to continue (to the next day-tomorrow).2.Next day flashes. Press to select second activeday. Press to continue and so on.

if you do not want a particular day to be included,press to continue (without pressing ).

9

3. To deselect any day press till you reach thechosen day and press .

Page 10: miracle booklet 1 - hvi.com.au

10

Active Days on Odd or Even DatesPress to select Odd or Even datesas active days.

Selecting Start timesSelect up to 4 Start times during 24 hours of eachselected days. Press , after the last day of the week.A flashes on the right and new time field isdisplayed. Press to set the hour of the first starttime. Press and to set minutes. Press toconfirm and to open next start time. A icon nowflashes (under the first). New time field opens. Press to set hour, Press to confirm. Press to setminutes. press to confirm and so on with next 2start times. If you want less than 4 start times, pressthe button without entering a time

Note! 31nd of any month and the29th of February considered asOdd days.

Active Days with CalenderSet irrigation/non irrigation days.1. Press to choose first for interval count. Press to activate the date.2. To define any day as non irrigation day press to selecte the day and to define it as non irrigation day

Note! The controller sorts the start timesautomatically. If you scheduled setup starttime 2 earlier then start time 1, the controllerautomatically will switch between them.

Page 11: miracle booklet 1 - hvi.com.au

User Guide 11

You have created your first irrigation program –program A. You can set two programs more (B,C)with selected Active Days. To move on to the nextprogram press .

Note! It is not recommended to switchamong programs during programming.Use this method in case of changing oneparameter to all of your programs(e.g. Rain delay)

Selecting Valves and irrigation timeValves are listed (1 to 9) at the bottom of thescreen. Press after setting last start time.A flashes on top of the first valve, a glass houricon appears, and a new time field (to setduration of irrigation for this valve) is displayed.Press to set time and to move on the secondand so on for each of the connected valves.

Page 12: miracle booklet 1 - hvi.com.au

12

Program I (pulses irrigation)Set Start time and End time to define anirrigation window (hours & min.).Set Open time and Close time (hours, min.& sec.) to defined the pulse duration andtime between pulses.To enable program I Press continuously together till - I - appears (A B C I).Set Active Days as for programs A B C (seepage 9-10).Select first valve as for programs A B C (seepage 11). The time parameters flash on theright of the screen, (same place as the StartTimes for programs A B C, see page 11).Set time parameters for selected valve:a. Enter the Start Time for the Time Windowb. Enter the End Time for the Time Windowc. Enter the Open Time, (time in hours, min., sec. that valve will be open).d. Enter the Close Time, (time in hours, min., sec. that valve will be closed).

Note: Set the irrigation days for the entirevalves in program I.Set the time parameters for each selectedvalve individually.

Page 13: miracle booklet 1 - hvi.com.au

User Guide 13

Note! When selecting program D, programs A, B, C andI are not available. By switching to program D, ALLOTHER PROGRAMS (A,B,C,I) WILL BE ERASED.To switch back from program D to A, B,C, presstogether continuously till the letters ABC appear.

Rain DelayEnables delay program for selected number of daysif for example your weather forecast is for rain.Press or till icon is flashing.Press the to enable it. Press the / repeatedlyto enter the number of days that you wish yourprogram to be set on. At the end of this period,the program will resume operation as originally set.

Program DProgram D is different from programs A,B,C. Activedays and start times are set specifically for the eachselected valve. To activate program D Presstogether continuously till the letter D appears. Pressthe button to select a valve.Set Active Days for the selected valve as for programsA B C, (see page 9). Select Start Times for selectedvalve and active days, same as setting Start Timesfor programs A B C,(see page 10).Set irrigation duration for each valve (see pag 11).Select a second valve (if required) and repeat thesame steps as detailed above andso on to other required valves.

Note!When Rain Delay icon appears ( ),the chosen program is disabled.

Page 14: miracle booklet 1 - hvi.com.au

14

Water BudgetEnables to reduce or increase irrigation time(200%-10%) to match seasonal changes.Press till -%- flashes.Press or to increase or decreaseirrigation time in your selected program bypercentage.

Note: Water Budget has to be implemented for each program individually. It is not available for program I. If water budget ≠ 100% the % icon will be shown on screen.

Manual Operation of program:Press or till the upper icon is displayedand flashing. Press to activate (current programwith selected valves and operating time only).Press to activate the program.

Page 15: miracle booklet 1 - hvi.com.au

User Guide 15

Optional Sensor inputWhen Soil moisture sensor is activated(open = ON) the irrigation programthat is currently run will stop(can be activated with allprogram but program C).

Manual Operation of a selected valve:Press or till the lower icon is displayedand flashing. Press to select a valve. Pressto set a run time for the selected valve (hours,min.).Press .The digits will flash. Press againto activate the valve. Press to disable it.Repeat the same for each valve you wish.

Note:The sensor input is normally close.

Page 16: miracle booklet 1 - hvi.com.au

www.netafim.com

Netafim Irrigation Inc. products are guaranteed to be freefrom defects in material and workmanship for a period of one(1) year from the date of delivery.This warranty does not apply where equipment is not usedand installed strictly in accordance with Netafim specificationsand User Manual. Neither does it apply to failures caused bylightning strikes or damage due to freezing temperatures,Water corrosion (in AC models only) or mechanical causes(e.g. lawn-mowers) . Netafim is not liable for indirect, incidentalor consequential damage in connection with the use ofequipment.To receive warranty benefits, customers should return defectiveparts to the nearest Netafim distributor.Netafim reserves the right to alter, modify or redesign itsproducts, pricing and warranty at all times without creatingany liability for the obsolescence of customer inventory ofsuch parts or products.This manufacturer warty policy may apply differently in differentcountries.

For more information, contact your Netafim distributor orTel: 972 8 6473111 Fax: 972 8 6420098Email: [email protected]

MiraclePlus is protected internationally by world-wide patent.

HD

L B.

1205