mini make up air - thermolec · mini make up air today's airtight construction requires fresh...

2
MINI MAKE UP AIR MINI MAKE UP AIR Today's airtight construction requires fresh air to eliminate excess humidity and indoor pollutants caused by cleaning products, smoking and pets which make the environment both uncomfortable and unhealthy. Equipped with the most advanced modulating controller and air sensor, Thermolec’s Mini Make Up Air uses the minimum amount of energy required to meet your needs. The air flow sensor detects the amount of air flowing through the unit and modulates the heating capacity accordingly, maximizing savings. The controller also monitors abnormal conditions or fan failure and will safely control the elements to avoid potential hazards. 4 NEW SIZES FULLY MODULATING irtight construction requires fresh air to eliminate excess humidity and caused by cleaning products, smoking and pets which make the environme able and unhealthy . with the most advanced modulating controller and air sensor, Thermolec Air uses the minimum amount of energy required to meet your needs. The a tects the amount of air flowing through the unit and modulates the heating ca y , maximizing savings. The controller also monitors abnormal conditions d will safely control the elements to avoid potential hazards. 4 NEW SIZES FULLY MODUL LATING REVERSIBLE AIRFLOW WASHABLE FILTER MODULATING TEMP. SENSOR SPEED CONTROL DAMPER FAN

Upload: duongthien

Post on 24-Feb-2019

219 views

Category:

Documents


0 download

TRANSCRIPT

MINI MAKE UP AIRMINI MAKE UP AIR

Today's airtight construction requires fresh air to eliminate excess humidity and indoor pollutants caused by cleaning products, smoking and pets which make the environment both uncomfortable and unhealthy.

Equipped with the most advanced modulating controller and air sensor, Thermolec’s Mini Make Up Air uses the minimum amount of energy required to meet your needs. The air flow sensor detects the amount of air flowing through the unit and modulates the heating capacity accordingly, maximizing savings. The controller also monitors abnormal conditions or fan failure and will safely control the elements to avoid potential hazards.

4 NEW SIZES

FULLY MODULATING

irtight construction requires fresh air to eliminate excess humidity and caused by cleaning products, smoking and pets which make the environmeable and unhealthy.

with the most advanced modulating controller and air sensor, ThermolecAir uses the minimum amount of energy required to meet your needs. The atects the amount of air flowing through the unit and modulates the heating cay, maximizing savings. The controller also monitors abnormal conditions

d will safely control the elements to avoid potential hazards.

4 NEW SIZES

FULLY MODULLATING

REVERSIBLEAIRFLOWWASHABLE FILTERMODULATING

TEMP. SENSORSPEED CONTROLDAMPER FAN

4 NEW SIZES

WASHABLE FILTER

Fan performance:Available sizes:

MODULATINGTEMP. SENSOR

SPEED CONTROL

DAMPER

FAN

Units are available in a wide range of sizes from 6” to 12” collars, single phase or 3 phase up to 20 kW capacity. See size chart and ordering example below.

All units are equipped with high quality fans with ball bearings for lowest noise and longest life. Based on the size of unit, the fans provide the airflow required up to 600 CFM

Built-in dampers are also included to provide a complete mini make up air solution in a com-pact package.

The fan speed controller allows fine tuning of the air volume required based upon your specific installation.

Electronic temperature sensors control the heater proportionally to maintain the pre-set air temperature in the duct and match the exact capacity required minimizing operating costs.

Easy access allows the filter to be removed, washed and be replaced without any tools, eliminating unnecessary costs.

2060 LUCIEN-THIMENS, MONTREAL ● QUEBEC, CANADA, H4R 1L1 ● Tel.:514-336-9130 Fax:514-336-3270 ● w w w . t h e r m o l e c . c o m

Reversible AirflowThere is no need to modify the fan or any wiring to reverse the airflow, simply rotate the unit 180°. This is possible due to the automatic thermal cutouts located on both the top and bottom of the unit.

NOTE:Not suitable for vertical airflow.

Collar size (inches) Voltage/PhasekW

Fan Damper

When ordering please specify the collar size, kW and voltage/phase as in the following example:

FER-12-20-600/3

X

Y

Z

600 CFM FanCollar Size 6" 6" 8" 10" 12"Single Phase • • • •Three Phase • • • •Max Voltage 240 600 600 600 600Max kW

ControlsIncluded

3 3 6 10 20Dimensions( X x Y x Z )

18 1

/2" x

8" x

10

1/2"

X

x

Y

x

Z

31 1

/2" x

10"

x 1

3 3/

4"

36 1

/2" x

15"

x 1

5"

36 1

/2" x

15"

x 1

5"

43 1

/2" x

16"

x 2

1"

100 CFM Fan 300 CFM Fan

RoomController

CurrentSensor

CurrentSensor

CurrentSensor

CurrentSensor

0

100

200

300

400

500

600

700

800

0 0.05 0.1 0.15 0.2 0.25 0.3 0.35

8 & 10”12”

6”

CFM

Static PressureNote: Sizes are approximate and may change without notice

V1.

0 Ja

n. 2

012