Page 1: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

Quality you can rely on

Middle Ear ImplantsInstruments and Miscellaneous

Page 2: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

Middle Ear Implants

Page 3: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

Middle Ear Implants

In otoplasty, middle ear implants serve as re-

placements for damaged or redundant ossic-

les. They restore the defect mechanical chain

of sound transmission between the tympanum

and the stapes footplate.

There are two basic types of middle ear implants:

Total implants, TORP ( Total Ossicular Replacement

Prosthesis) – total ossicular replacement; functio-

nal stapes footplate

Partial implants, PORP ( Partial Ossicular Replace-

ment Prosthesis) – partial ossicular replacement;

stapes still present; functional stapes footplate

Page 4: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

According to Wullstein (1968), tympa-noplasty requires a constant assess-ment of the present situation, each of which requires a special solution. One of the great challenges is recon-structing a broken or fixed ossicular

chain to restore optimal hearing. Since the dawn of middle ear surgery, a variety of materials have been used. An ever-advancing development in materials technology has led to the use of titanium since 1994.

Advantages:• Manufactured from one single piece• Excellent stability and handling• Large choice of lengths• Adjustable head angle (exception: 3 mm length)

Art.-No. Length (mm)11830 3.0011835 3.5011840 4.0011842 4.2511845 4.5011847 4.7511850 5.0011855 5.5011860 6.0011865 6.5011870 7.00

Art.-No. Length (mm)11930 3.0011935 3.5011940 4.0011942 4.2511945 4.5011947 4.7511950 5.0011955 5.5011960 6.0011965 6.5011970 7.00

The reconstruction of the sound-conducting chain is one of the major tasks of modern middle ear surgery.

Titanium is distinguished from all other materials used so far by its high biocompatibility and stability with high rigidity and low weight. By a simp-le individual adjustment in length and angle partial and total prosthesis can be ideally adapted to any anatomical situation. This middle ear implant sys-tem made of pure titanium has been able to provide the young as well as experienced otologist with a tool to safely replace destroyed ossicles and to reproduce the patient‘s lost hearing.

Central headOffset head

PD Dr. med. Carsten V. DalchowHead of the Department of Otolaryngology, Head and Neck Surgery, Plastic Surgery and Allergology Hospital Frankfurt Höchst, Germany

4 SPIGGLE & THEIS | Middle Ear Implants

Part ial implantMiddle ear implants

Total implant

f ixed length, t i tanium, shaft ∅ 0. 3 mm, ster i le

Page 5: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

Advantages:• Manufactured from one piece of titanium• Optimal positioning on the stapes head• Large choice of lengths• Different dimensions available

Partial implant designs with slitted bells provide the option of placing the implant on the complete bow of the stapes sides when the stapes head is no longer there. This placement reduces the risk of implant dislocation. The implant head can be either centrally (round head) or

• Central head or offset head with additional groove• Complete bell or bell with slits• Excellent stability and handling

eccentrically (oval head) attached to the implant shaft. The oval headed version has an additional groove for an improved fitting of the malleus. A clearer view for positi-oning the bell end is possible due to openings found in both versions.

Central head with slitted bell

Art.-No. Insert length (mm)12705 0.5012710 1.0012712 1.2512715 1.5012717 1.7512720 2.0012722 2.2512725 2.5012730 3.0012735 3.50

Offset head with slitted bell

Art.-No. Insert length (mm)12805 0.5012810 1.0012812 1.2512815 1.5012817 1.7512820 2.0012822 2.2512825 2.5012830 3.0012835 3.50

Central head with complete bell

Art.-No. Insert length (mm)12905 0.5012910 1.0012912 1.2512915 1.5012917 1.7512920 2.0012922 2.2512925 2.5012930 3.0012935 3.50

SPIGGLE & THEIS | Middle Ear Implants 5

f ixed length, t i tanium, shaft ∅ 0 . 3 mm, ster i le

Part ial implant

Page 6: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

Total- Implants

var iable length, t i tanium, shortenable, ster i le

Shaft ∅ 0.4 mm

· Two parts (shaft with head and separate shoe)· No sharp ends

Art.-No. Material Overall Length (mm)

11100 titanium 2.8 - 7.811200 titanium 2.3 - 7.3

Shaft ∅ 0.4 mm

· Adjustable shaft· Two pieces (with head and separate shoe)

Art.-No. Material Overall Length (mm)

11500 titanium 2.8 - 7.811600 titanium 2.3 - 7.3

Shaft ∅ 0.3 mm

· Two pieces (shaft with shoe and separate head)· Reduction in weight due to 0.3 mm shaft diameter

Art.-No. Material Overall Length (mm)

11300 titanium 3.5 - 7.511400 titanium 3.0 - 7.0

Advantages:• Shaft can be shortened to required length in 1 mm intervals

6 SPIGGLE & THEIS | Middle Ear Implants

Part ial implant

Page 7: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

Shaft ∅ 0.3 mm

· Two pieces (shaft with bell and separate head)· Reduction in weight due to 0.3 mm shaft diameter

Art.-No. Material Overall Length (mm)

12100 titanium 2.5 - 5.512200 titanium 2.0 - 5.0

Advantages:• Shaft can be shortened to required length in 1 mm intervals

Overall length

1 mm

Insert length

SPIGGLE & THEIS | Middle Ear Implants 7

Steri le, t i tanium

Part ial implant

Insert length / Overal l length

Variable length

ATTENTION:Insert length = Overall length - 1 mm

Page 8: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

Dummy sizers

Storage and Ster i l izat ion Container

For t i tanium middle ear implants

For dummy sizers

· Dummy to determine required length· Similar in form to original implant· Length indicated on implant head· Single or set available· Non-sterile · Multi use· Special container for sterilizing available

Attention:The dummies are comparatively wide and have no smooth surface. The use of dummies as implants is strictly prohibited!

Art.-No. Overall-Length (mm)

Art.-No. Insert Length (mm)

11000-D20 2.00 12000-D05 0.5011000-D25 2.50 12000-D10 1.0011000-D30 3.00 12000-D15 1.5011000-D35 3.50 12000-D17 1.7511000-D40 4.00 12000-D20 2.0011000-D45 4.50 12000-D25 2.5011000-D50 5.00 12000-D30 3.0011000-D55 5.50 12000-D35 3.5011000-D60 6.00 12000-D40 4.0011000-D65 6.50 12000-D45 4.5011000-D70 7.00 12000-D50 5.0011000-D75 7.50 12000-D55 5.50

Dummy sizer for Torp

Dummy sizer for Porp

Art.-No. DescriptionDummy Box

Sterilization container for dummy sizers

Dummy Set

Sterilization container with 12 total and 12 partial dummy sizers

(1 piece per size)

8 SPIGGLE & THEIS | Middle Ear Implants

Shortening instruments

Reference instrument

Page 9: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

PF001-10

PF001-11

PF001-12

PF001-13

10-715-00

Basic block for shortening scales (total and partial implants)

Shortening scale for use with the basic block for total implants 11100, 11200, 11500, 11600

Shortening scale for use with the basic block for partial implants 12100, 12200

Shortening scale for use with the basic block for total implants 11300, 11400

Shortening forceps with extra strong jaw, 1.4 x 4.0 mm, 8 cm

Slide button control from 0-8 mm, 18.5 cm

Art.-No. Description10-651-00 Non-Dismountable10-652-00 Dismountable

18.5 cm

SPIGGLE & THEIS | Middle Ear Implants 9

For t i tanium middle ear implants

For middle ear prostheses

Shortening instruments

Reference instrument

Page 10: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

Insert ion instruments

For otological microsurgery

10-489-15

10-504-10

Hartmann, ear forceps

· Serrated and fine· Self-closing· Straight· Slim jaw· 0.8 x 4.0 mm· 8 cm

10-701-00

Helms, dressing forceps

· Straight, serrated· 2.8 mm· 15 cm

Hildmann, cartilage forceps

· Straight· 11 cm

Please see our otological instrument catalogue for the complete range of our otological instruments.

10 SPIGGLE & THEIS | Middle Ear Implants

Titanium Ear Instrument Set

Page 11: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

Hartmann ear forceps

· Non-magnetic· Straight· Fine· 1.0 x 6.0 mm· 8 cm

10-703-10

Hartmann ear forceps

· Non-magnetic· Fine· Straight· Self-closing· 8 cm

Art.-No. Description Size (mm)10-702-10 serrated 1.0 x 6.010-702-11 smooth 1.0 x 6.0

Coupling the VSB to existing anatomical structures can be greatly facili tated using non-magnetic Titanium instruments. With the help of the presented instruments

Vibrant Soundbridge (VSB) implantation is well established in the surgical treatment of sen sorineural as well as combined hearing loss in e.g. revision middle ear surgery or complex atresia cases.

frequently used during such operations, the VSB can be easily positioned and will no longer be displaced by a magnetic ghost hand.

Prof. Dr. med. B. Wollenberg Director of the clinic for Otolaryn-gology University HospitalSchleswig-Holstein, Campus Lübeck, Germany

8 cm

8 cm

SPIGGLE & THEIS | Middle Ear Implants 11

Prof. Wollenberg

Titanium Ear Instrument Set

Page 12: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

Micro forceps

· Non-magnetic· Anatomical· 1 mm· 15 cm

10-605-10

Micro needle

· Non-magnetic· 16 cm

Art.-No. Description10-600-00 short curve, slightly curved10-601-00 long curve, very slightly curved

Micro hook

· Non-magnetic· Sharp· 1 mm· 16 cm

Art.-No. Angle10-603-10 90°10-604-10 45°

16 cm

16 cm

15 cm

12 SPIGGLE & THEIS | Middle Ear Implants

Titanium Ear Instrument Set

Prof. Wollenberg

Page 13: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

SPIGGLE & THEIS | Middle Ear Implants 13

Notes

Page 14: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

14 SPIGGLE & THEIS | Middle Ear Implants

Notes

Page 15: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical
Page 16: Middle Ear Implants - MediTop · Middle Ear Implants. In otoplasty, middle ear implants serve as re-placements for damaged or redundant ossic-les. They restore the defect mechanical

© 2019 by SPIGGLE & THEIS Medizintechnik GmbH Modification and errors - including pictures - reserved.Please note also that not all goods might be for sale in your country.

F_M

EI_E

_01

Burghof 14 · 51491 Overath · Germany Phone: +49 2206 90 81 - 0 Fax: +49 2206 90 81 - 13 in fo@spigg le-theis .comw w w. s p i g g l e - t h e i s . co m