microsoft powerpoint - fcm20021016 [compatibility mode]

Upload: ivan-tonja

Post on 05-Apr-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    1/38

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    2/38

    Completing the chain

    Fuel Conditioning Module, FCM

    Presenter Name

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    3/38

    Fuel Conditioning Module, FCM

    www.alfalaval.com Alfa Laval Slide 3

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    4/38

    Completing the chain

    www.alfalaval.com Alfa Laval Slide 4

    Complete fuel treatment with extensive

    automation, high quality and reliability froma single supplier.

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    5/38

    Incorporating a

    new generationof controller.

    The FCM is fully

    Automatic Compact Flexible

    www.alfalaval.com Alfa Laval Slide 5

    automated withextensive remotecontrolpossibilities.

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    6/38

    Automatic Compact Flexible

    www.alfalaval.com Alfa Laval Slide 6

    Common design

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    7/38

    Block assemblies

    integrating severalfunctions allowcompact design.

    Automatic Compact Flexible

    www.alfalaval.com Alfa Laval Slide 7

    Control functionsand motor starterscollected in centralpillar.

    Service areas foreasy maintenance.

    Same capacity

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    8/38

    Easily configured to

    meet the requirementsof any specific engineor engine room layout.

    Automatic Compact Flexible

    www.alfalaval.com Alfa Laval Slide 8

    Supply andconditioning sectionscan be delivered asseparate units.

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    9/38

    Automation more thanviscosity control Detailed process information for all

    control functions.

    Automatic start-up sequence.

    www.alfalaval.com Alfa Laval Slide 9

    read-out of fuel consumption.

    Automatic start-up after power failure.

    If an emergency should occur theautomation can easily be bypassed.

    the list is long

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    10/38

    Process control and monitoring

    Output activation of valves

    and electric motors

    Input from sensors andfeedback signals

    www.alfalaval.com Alfa Laval Slide 10

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    11/38

    Remote monitoring and control

    1. The engine control

    room console.

    2. FCM panel fromAlfa Laval.

    www.alfalaval.com Alfa Laval Slide 11

    3. The centralautomation system.

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    12/38

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    13/38

    Integration with centralautomation system

    www.alfalaval.com Alfa Laval Slide 13

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    14/38

    For shipyards and enginebuilders, the FCM offers ... Space-saving design.

    Flexibility to meet differentcustomer and engine demands.

    Easy installation.

    www.alfalaval.com Alfa Laval Slide 14

    Factory tested, minimumcommissioning time and costs.

    Single supplier for complete

    fuel treatment system. Easy integration with onboard

    computer system.

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    15/38

    For ship or plant operators ...

    Innovative design makes operation and

    maintenance easy.

    Full automation means fewer man-hours requiredfor day-to-day operation.

    www.alfalaval.com Alfa Laval Slide 15

    Same controls as Separation Unit, SU, help crewbecome familiar with equipment.

    Proven key components.

    Single supplier for complete fuel treatment system.

    AL worldwide service.

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    16/38

    Key components and features

    www.alfalaval.com Alfa Laval Slide 16

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    17/38

    Key components and features

    Process controller

    www.alfalaval.com Alfa Laval Slide 17

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    18/38

    Key components and features

    Process controller

    EPC 50B fully

    automatic systemwith options forremote control.

    www.alfalaval.com Alfa Laval Slide 18

    Displays functionsettings, processinformation andalarms in clear

    text.

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    19/38

    Key components and features

    Alfa Laval automatic filter

    www.alfalaval.com Alfa Laval Slide 19

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    20/38

    Key components and features

    Alfa Laval automatic filter Continuous automatic back-

    flushing ensures high efficiencyand minimum maintenance.

    Automatic drain valve which

    www.alfalaval.com Alfa Laval Slide 20

    intervals eliminates the need formanual draining.

    Can be installed on Cold or

    Hot side.

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    21/38

    Key components and features

    Heaters

    www.alfalaval.com Alfa Laval Slide 21

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    22/38

    Key components and features

    Heaters M6 model with

    high efficiencyand small hold-upvolume enablesquick response

    www.alfalaval.com Alfa Laval Slide 22

    at changing loadconditions.

    The FCM can alsobe supplied with

    electric or shell &tube type heaters.

    Shell & tubeheat exchanger

    Electric heater

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    23/38

    Key components and features

    Screw pumps

    www.alfalaval.com Alfa Laval Slide 23

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    24/38

    Key components and features

    Screw pumps

    Three-spindle screw

    type pumps designedspecifically for HFO.

    Shaft seal on suction

    www.alfalaval.com Alfa Laval Slide 24

    side to minimizeleakage.

    Operate on a one-on,

    one-standby basiswith automatic shiftwhen necessary.

    Circulation pumpsSupply pumps

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    25/38

    Key components and features

    Viscosity sensor block

    www.alfalaval.com Alfa Laval Slide 25

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    26/38

    Key components and features

    Viscosity sensor block EVT20, measures viscosity

    against set value. Controller adjusts heaters to

    maintain correct viscosity.

    www.alfalaval.com Alfa Laval Slide 26

    Torsional vibrationmeasuring principle; notaffected by variations inpressure or flow.

    No moving parts to wear out.

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    27/38

    Key components and features

    Pressure transmitter

    www.alfalaval.com Alfa Laval Slide 27

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    28/38

    Key components and features

    Pressure transmitter Easy to adapt pressure

    limits from controller. Possibility to see

    pressure displayed for

    www.alfalaval.com Alfa Laval Slide 28

    supply and circulation.

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    29/38

    Key components and features

    Flow transmitter

    (behind cabinet)

    www.alfalaval.com Alfa Laval Slide 29

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    30/38

    Key components and features

    Flow transmitter Installed on the

    pressure side of thesupply pumps tomonitor actual fuel

    www.alfalaval.com Alfa Laval Slide 30

    .

    Instantaneous andaccumulated flowdisplayed on the

    process controller.

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    31/38

    Key components and features

    Control cabinet

    www.alfalaval.com Alfa Laval Slide 31

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    32/38

    Key components and features

    Control cabinet Process controller of

    the same type usedin the Alfa LavalSeparation Unit.

    www.alfalaval.com Alfa Laval Slide 32

    All motor startersin separatecompartments.

    Manual operation ofall critical functions.

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    33/38

    Key components and features

    Service areas

    www.alfalaval.com Alfa Laval Slide 33

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    34/38

    Key components and features

    Service areasInnovative design and

    service platformsmake maintenanceand operation easy.

    www.alfalaval.com Alfa Laval Slide 34

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    35/38

    Key components and features

    Summary Process controller

    Automatic filter Heaters

    Screw pumps

    www.alfalaval.com Alfa Laval Slide 35

    Viscosity sensor Pressure transmitter

    Flow transmitter

    Control cabinet

    Service areas

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    36/38

    Flow diagram

    www.alfalaval.com Alfa Laval Slide 36

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    37/38

    Capacities and dimensions

    FCM 2100

    FCM 2200

    FCM 3100FCM 3200

    FCM 3300

    www.alfalaval.com Alfa Laval Slide 37

    Dimensions

    FCM 1000 series FCM 2000 series FCM 3000 series2.50 x 1.15 x 1.90 m 3.00 x 1.15 x 2.10 m 4.50 x 1.50 x 2.25 m

    FCM 1100

    FCM 1200

    FCM 1300

    60

    60 Hz 50 Hz

    10 20 30 40 50 70 MW0

  • 8/2/2019 Microsoft PowerPoint - FCM20021016 [Compatibility Mode]

    38/38