microscan v5 overview.ppt - intech instruments · 1 microscan v5 s.c.a.d.a and datas.c.a.d.a and...

34
1 MicroScan V5 S.C.A.D.A and data S.C.A.D.A and data-logging logging software and associated software and associated hardware from hardware from MicroScan MicroScan - Connects to Connects to MicroScan Software connects Analogue Inputs & Outputs MicroScan Software connects to the Intech Micro 2100 series Remote Station hardware modules to form a complete supervisory control and data acquisition system. Analogue Inputs & Outputs Digital Inputs & Outputs PLCs Controllers

Upload: lykhue

Post on 28-Sep-2018

233 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

1

MicroScan V5S.C.A.D.A and dataS.C.A.D.A and data--logging logging

software and associated software and associated hardware fromhardware from

MicroScan MicroScan -- Connects toConnects to

MicroScan Software connects Analogue Inputs & OutputsMicroScan Software connects to the Intech Micro 2100 series Remote Station hardware modules to form a complete supervisory control and data acquisition system.

Analogue Inputs & OutputsDigital Inputs & Outputs

PLCs

Controllers

acqu s t o syste

Page 2: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

2

MicroScan MicroScan -- CapabilityCapability

MicroScan combines all the basic d t l i f ti i t

Analogue Inputs & OutputsDigital Inputs & Outputsdatalogging functions into one

package and performs the function of regularly gathering information, checking alarm states - displaying the data, plus historical analysis and (MMI) operator interface.

g p p

PLCs

Controllers

RS232 to RS422/485converterPC-Networks

MicroScan is made up of the MicroScan is made up of the following main Modules:following main Modules:

Recorder Module: Real Time Trends Recorder Module: Real Time Trends D t Di lD t Di lUp to: 1320 I/OUp to: 1320 I/O Data Displays Data Displays Historical AnalysisHistorical Analysis

Mimic Module: Operator Interface Mimic Module: Operator Interface Up to: 6400 I/OUp to: 6400 I/O MMIMMIController ModuleController ModuleInterface Module: Field Remote Stations and PLC’sInterface Module: Field Remote Stations and PLC’sNetwork Module: Data SharingNetwork Module: Data SharingDDE: Link in to other Windows ApplicationsDDE: Link in to other Windows Applications

Page 3: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

3

Page #

11The RecorderThe Recorder

The recorder forms the ‘heart’ 11Page #

2020Page #

5353Page #

8484

The recorder forms the heart of the MicroScan system.

The recorder displays up to 100 pages.

8484Page #

9595

The RecorderThe Recorder

Each page can Page 11

display up to 10 different input signals.

Analogue Inputs/ OutputsDigital Inputs/ Outputs

PLCs

Controllers

Digital Inputs/ Outputs

Page 4: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

4

The recorder functions operates continuously including automatic logs & reports plus alarm handling and store file

The RecorderThe Recorder

reports, plus alarm handling and store file generation.

The recorder scans and loads data onto the hard disk at preset rates ensuring safe storage for later retrieval and analysis.

RecorderRecorderPowerful trendingPowerful trendingPowerful trending Powerful trending

and and Historical retrievalHistorical retrieval

Page 5: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

5

Digital InputsDigital Inputs(On/Off Indication)(On/Off Indication)

Analogue InputsAnalogue Inputs

Page 6: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

6

Hyperlink page Hyperlink page selection for instant selection for instant

page accesspage access

Password protection for Password protection for changes to settingschanges to settings

Page 7: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

7

Popup Colour Popup Colour Key Index..Key Index..

..or expand ..or expand Navigation TreeNavigation Tree

Page 8: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

8

Use The Mouse tracker Use The Mouse tracker to pinpoint times, dates to pinpoint times, dates and values of interestand values of interest

Track throughTrack throughtime and reallytime and really

see what see what happenedhappened

Page 9: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

9

Select which Select which lines to viewlines to view

Popup Tool Bar for quick Popup Tool Bar for quick p p qp p qscale changes, printing, scale changes, printing,

measuring time & values, measuring time & values, showing/hiding inputsshowing/hiding inputs

Page 10: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

10

Check on vital Alarm statesCheck on vital Alarm states

Alarms:Alarms:Alarms can perform the following states: Alarms can perform the following states:

Activate the PC beeperActivate the PC beeperActivate the PC beeper,Activate the PC beeper,Send an alarm text message to cell phone(s).Send an alarm text message to cell phone(s).Activate an alarm relay to:Activate an alarm relay to:

Activate an autoActivate an auto--dialler,dialler,Activate Alarm bells.Activate Alarm bells.

Page 11: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

11

MA5: MA5: Text messages allow you to Text messages allow you to keep in touch with your processkeep in touch with your process

MA5 Examples:MA5 Examples:

Page 12: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

12

It doesn’t have to be all graphsIt doesn’t have to be all graphsAlphaAlpha--Numeric indicationNumeric indication

Switch between Graphs and Data instantlySwitch between Graphs and Data instantlyp yp y

Choose from Choose from the Listthe List

Page 13: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

13

Easy to follow menusEasy to follow menus

Easily view the Last Easily view the Last Pages looked atPages looked at

Page 14: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

14

OnOn--Line HistoryLine HistoryThis is a powerful and convenient This is a powerful and convenient history viewing window. history viewing window. y gy g

Any data stored by the Recorder can be:Any data stored by the Recorder can be:retrieved and viewed in a trend format, retrieved and viewed in a trend format, exported through the Windows clipboard, or exported through the Windows clipboard, or converted to a format suitable for converted to a format suitable for

d h t d t bd h t d t bspreadsheets or databases,spreadsheets or databases,

without interrupting the Recorder!without interrupting the Recorder!

Data Movement Buttons just like a CDData Movement Buttons just like a CD--Player. Player. Move the graph window through history.Move the graph window through history.

Page 15: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

15

Adjust the viewing window time Adjust the viewing window time scale from 5 Minute to 31 daysscale from 5 Minute to 31 days

Easy Search Easy Search FunctionFunction

Page 16: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

16

Select which lines you want to Select which lines you want to look at, what scale, colour...look at, what scale, colour..., ,, ,

print it or ...print it or ...

Page 17: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

17

Export it to another Export it to another applicationapplication

On Line calibration withOn Line calibration with

ISO 9000 TrackingISO 9000 Tracking

Page 18: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

18

EventsEvents are logged are logged automatically.automatically.

CalibrationCalibration Log provides Log provides ISO 9000 TrackingISO 9000 Tracking

NotesNotes for operatorfor operatorcomments.comments.

OperatingOperating Log provides Log provides Usage TrackingUsage Tracking

Page 19: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

19

StationStation Log gives easy Log gives easy viewing of station statusviewing of station status

Fast - Simple - Painless !

Setup/ConfigurationSetup/Configuration

With our graphical representation the Remote Station network and PLC’s are easily set-up and maintained.

All the parameters and controlsAll the parameters and controls are shown leaving no gaps or hidden mistakes to be found (or worse NOT found).

Page 20: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

20

Full control over all program Full control over all program aspects in one easy to use areaaspects in one easy to use area

“So - everything is visual, can I see something other than graphs and data ?”

The MimicThe MimicMMI Man Machine InterfaceMMI Man Machine Interface

something other than graphs and data ?

YES!YES!You can use all the data collected by MicroScanYou can use all the data collected by MicroScan

and show it in a diagrammatical form (eg. Show how full the tanks are and what

pumps are running).

Page 21: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

21

Analogue Level Analogue Level Indicators...Indicators...

On/Off Indicators On/Off Indicators (text, flashing (text, flashing

colours, popups)...colours, popups)...

Page 22: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

22

RealReal--time values time values IndicatedIndicated

Meaningful representation with Meaningful representation with easily recognisable symbolseasily recognisable symbols

Page 23: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

23

Add buttons to Add buttons to change setpoints, change setpoints,

alarms, swap pages, alarms, swap pages, start/stop motors...start/stop motors...

Up to 50 Mimic pages are Up to 50 Mimic pages are p p gp p gavailable via Hyperlinks...available via Hyperlinks...

Page 24: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

24

If you want to avoid bored fingers If you want to avoid bored fingers playing on the nightplaying on the night--shift shift -- all/any all/any pages can be password protected.pages can be password protected.

This is the ‘Fun’ part!This is the ‘Fun’ part!This is the Fun part!This is the Fun part!

Lots of room for the imagination here!Lots of room for the imagination here!

Begin with a blank page...Begin with a blank page...

Page 25: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

25

RealReal--time values,time values,

On/Off indicators,On/Off indicators,On/Off indicators,On/Off indicators,

Buttons,Buttons,

Hotspots,Hotspots,

Text,Text,

BarBar--Graphs,Graphs,

...there’s room for ...there’s room for custom PLC recipes.custom PLC recipes.

Add background bitmaps drawn with Add background bitmaps drawn with your favourite graphics editor (Paint your favourite graphics editor (Paint

Shop Pro, CorelDraw, PaintBrush etc).Shop Pro, CorelDraw, PaintBrush etc).

Page 26: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

26

Drop a few controls in Drop a few controls in the appropriate placesthe appropriate places

It is now finished and It is now finished and ready to put onlineready to put online

Page 27: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

27

Accessory: Tool BoxAccessory: Tool BoxUser Friendly Special Function UtilityUser Friendly Special Function Utility

MicroScan Tool Box MicroScan Tool Box --Function Block SummaryFunction Block Summary

HumidityHumidityDew PointDew PointMoisture ContentMoisture Content

Math Math -- AverageAverageMath Math -- FormulaFormulaMathMath -- Rate ofRate of

Step Control Step Control -- StepStepStep Control Step Control --MasterMaster

Moisture ContentMoisture ContentBatch AverageBatch AverageBatch MinBatch MinBatch MaxBatch Max

Batch Save to DBatch Save to D--BaseBase

Math Math Rate of Rate of ChangeChangeMath Math -- SumSumMath Math -- TrigonometryTrigonometryMath Math -- Tank VolumeTank Volume

Math Math -- TotalTotal

Time Time -- Time ClockTime ClockTime Time -- Multi TimerMulti TimerTime Time -- PC ClockPC ClockTime Time -- PulsePulseTime TimerTime Timer

Page 28: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

28

NetworkingNetworking

The sharing of data between the The sharing of data between the ti d i tti d i t

Active Node

active and passive computer active and passive computer nodes running MicroScan is nodes running MicroScan is supported on both:supported on both:

the file server styled network, andthe file server styled network, andthe Windows multiple independent the Windows multiple independent server network.server network.

Security is provided to regulateSecurity is provided to regulate

Net

wor

kPassive Node

Passive Node

Security is provided to regulate Security is provided to regulate the sharing of data.the sharing of data.

Node

More Passive Nodes

Comprehensive Help Comprehensive Help always a click awayalways a click away

Page 29: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

29

We supply a comprehensive range of

The Remote StationsThe Remote Stations

pp y p gdata-collection and control devices.

Analogues Input/Output StationsDigital Input/Output Stations

MultiplexersRamp and P ocess Cont olle sRamp and Process Controllers

Remote Station IntroductionRemote Station Introduction

2100-A16

2100-A4

Up to 64 Remote Stations can be connected Up to 64 Remote Stations can be connected --any combinationany combinationRemote Station Power Supply options:Remote Station Power Supply options:

80 ~ 264Vac/dc80 ~ 264Vac/dc23 ~ 90Vdc23 ~ 90Vdc

More Remote Stations

2100-D10 ~ 28Vac/dc10 ~ 28Vac/dc

2100-AO

Page 30: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

30

21002100--A16 Remote StationA16 Remote Station

16 Analogue Inputs* Individually ConfigurableThermocoupleThermocouplePt100 or Pt1000mAmVV*16 Bit A/D

2 Analogue Outputs4~10mA0~20mA2~10V0~10V

4 Digital on/off InputsOpto Isolated

30 C

2100-A16

2100-A4

5 to 30 V DCOn/off statesPulses from flow meters etc

2 Relay Outputs* Expandable to 16 by adding the 2100-R Relay Expander* Alarm or Control outputs

On Board Controllers16 on/off controllers8 heat/cool controllers

More Remote Stations

2100-D

2100-AO

21002100--A4(e) Remote StationA4(e) Remote Station

4 Analogue Inputs4 Analogue Inputs* I di id ll C fi bl* I di id ll C fi bl* Individually Configurable* Individually ConfigurableThermocoupleThermocouplePt100Pt100mAmAmVmVVV*12 Bit A/D*12 Bit A/D

2 Analogue Outputs2 Analogue Outputs4~10mA4~10mA0~20mA0~20mA2~10V2~10V0~10V0~10V

2100-A16

2100-A4

4 Digital on/off Inputs4 Digital on/off InputsOpto IsolatedOpto Isolated5 to 30 V DC5 to 30 V DCOn/off statesOn/off statesPulses from flow meters etcPulses from flow meters etc

4 Relay Outputs4 Relay Outputs* Optional 8 outputs 2100* Optional 8 outputs 2100--A4eA4e* Alarm or Control outputs* Alarm or Control outputs

On Board ControllersOn Board Controllers4 on/off controllers (21004 on/off controllers (2100--A4)A4)4 heat/cool controllers (21004 heat/cool controllers (2100--A4e)A4e)

More Remote Stations

2100-D

2100-AO

Page 31: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

31

21002100--D Remote StationD Remote Station

12 Digital on/off InputsOpto Isolated5 to 30 V DC

2100-A16

2100-A4

Up to 500HzOn/off statesPulses from flow meters etc

12 Relay Outputs2 Amps 250 V AC

More Remote Stations

2100-D

2100-AO

21002100--AO Remote StationAO Remote Station

8 Analogue InputsmA or V selectable

8 Analogue OutputsmA or V selectable

2 Relay Outputs12 Digital Outputs

2100-A16

2100-A4

More Remote Stations

2100-D

2100-AO

Page 32: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

32

Connecting Field Station’s via Connecting Field Station’s via Data HiData Hi--WayWay

RS422/485 Data Hi-WayRS232

2100-SeriesLength of Data HiLength of Data Hi--way before a way before a booster is required:booster is required:

RS422 2 pair = 1.2km typicalRS422 2 pair = 1.2km typical

Option = MODBUS RTU

2100-IS

More Remote Stations

2100-Series

RS422 2 pair 1.2km typicalRS422 2 pair 1.2km typical

RS485 1 pair = 0.5km typicalRS485 1 pair = 0.5km typical

Data HiData Hi--way cable type is low way cable type is low capacitance data cable with overall capacitance data cable with overall screen screen -- cat5 or similarcat5 or similar

Connecting Field Station’s via Connecting Field Station’s via EthernetEthernet

HUB

2100-A16-NET

2100-Series

2100-NET

RS422/485

More Remote Stations

2100-Series

Page 33: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

33

Connecting Field Station’s via Connecting Field Station’s via Wireless Radio ModemWireless Radio Modem

Option = USB

RS232

2100-IS

RS422/485

2100-Series

RS422/485

Performance (900MHz ISM Band):Performance (900MHz ISM Band):Indoor Urban = Up to 450m*Indoor Urban = Up to 450m*

More Remote Stations

2100-Series

Outdoor Line of Sight:Outdoor Line of Sight:with Dipole = Up to 3km*with Dipole = Up to 3km*with High Gain Antenna = Up to 6km*with High Gain Antenna = Up to 6km*

*Subject to Terrain Conditions*Subject to Terrain Conditions

Connect to multiple remote Connect to multiple remote sites via Wirelesssites via Wireless

SB

or U

S

Page 34: MicroScan V5 Overview.ppt - Intech Instruments · 1 MicroScan V5 S.C.A.D.A and dataS.C.A.D.A and data--lologging software and associated hardware from MicroScan MicroScan --Connects

34

If you wish to find out more or see a live version of MicroScan in action please contact your nearest Intech Instruments Ltd outlet.

More InformationMore Information

your nearest Intech Instruments Ltd outlet. Thank-you for viewing our demonstration.

Christchurch: Ph: +64 3 343 0646Christchurch: Ph: +64 3 343 0646Fx: +64 3 343 0649

E-mail: [email protected]: www.intech.co.nz