Installation Guide
OVP Kit(Over Voltage Protection)
Art. 351427.033Issue 1, 2005-09
![Page 2: Micro BBU (6)](https://reader038.vdocuments.us/reader038/viewer/2022100514/577cdb931a28ab9e78a88e2d/html5/thumbnails/2.jpg)
7/28/2019 Micro BBU (6)
http://slidepdf.com/reader/full/micro-bbu-6 2/8
2 Installation Guide Over Voltage Protection Kit , 351427.033, v1-2005-09
Index
General .......................................................................................................................................2
Recommended tools ................................................................................................................... 2
Torque settings ........................................................................................................................... 2
Ordering information..................................................................................................................2
Scope of delivery........................................................................................................................3
Installation.................................................................................................................................. 4
General
This kit makes it possible to equip the MicroPower Outdoor System with an Over Voltage
Protection (OVP) unit. The OVP device protects the system from voltage spikes and surge
currents transmitted by the mains input. This over voltage protection kit contains a class C
protection. A class B protection must be mounted externally on the cabinets mains feed if
required.
Installation must be done by authorized personnel only.
Eltek Energy recommends that the system is powered down before installation of the kit.
Recommended tools
Standard equipment used by an authorized electrician. NOTE: All tools must be insulated.
Torque settings
The screw terminals on the OVP base must be tightened with 3.0Nm. The green/yellow earthcable must be fixed with a M6 nut to the PE copper plate with 6.0Nm.
Ordering information
Part number Description Net weight
105289 OVP kit 80gr
![Page 3: Micro BBU (6)](https://reader038.vdocuments.us/reader038/viewer/2022100514/577cdb931a28ab9e78a88e2d/html5/thumbnails/3.jpg)
7/28/2019 Micro BBU (6)
http://slidepdf.com/reader/full/micro-bbu-6 3/8
Installation Guide Over Voltage Protection Kit , 351427.033, v1-2005-09 3
I n s t a l l a t i o n m a n u a l
E l t e k
X x x x x x x x x x
X x x x x x x x x x X x x x x x x x x x
4
Scope of delivery
The Kit for OVP consists of the following components:
Part Note Quantity Unit
OVP 2 Pole OBO V25-B+C/1NPE 280V 1 1 pcs
Loom: OVP MicroPower PRSB 2 1 pcs
STRAP PLT 1,5mm 0 PANDUIT 3 5 pcs
Manual 4 1 pcs
3
1
2
![Page 4: Micro BBU (6)](https://reader038.vdocuments.us/reader038/viewer/2022100514/577cdb931a28ab9e78a88e2d/html5/thumbnails/4.jpg)
7/28/2019 Micro BBU (6)
http://slidepdf.com/reader/full/micro-bbu-6 4/8
4 Installation Guide Over Voltage Protection Kit , 351427.033, v1-2005-09
Installation
Step Description Comment OK
1 The mains input must be
turned off during theinstallation of this kit.
It is possible to mount
this kit without removing
the battery shelf.
However Eltek
recommends removing
the batteries and battery
shelf before installing the
OVP kit.
Turn OFF the external mains input breaker!
2 NOTE! If the 2 Pole ACInput Breaker Kit has
already been installed
always mount this kit to
the right hand side. The
drawing to the right
shows how to install both
kits.
3 Remove the End Stop on
the right hand side of the
mains input terminal
blocks. Mount the OVP
unit on the DIN bar. Push
the OVP unit against the
terminal blocks. Lock the
OVP unit with the End Stop.
2 8 2 / 2 8 4
W A G O
2 8 1 / 2 8 2
L 1
L 1
2 8 2 / 2 8 4
W A G O
2 8 1 / 2 8 2
N N
E
OBO
V25-B+C
OBO
C25-B+C
N-PE
CombiController CombiController
Best.-Nr. 5097061 Best.-Nr. 5095603
IP20 CE IP20 CE
N
L PE
![Page 5: Micro BBU (6)](https://reader038.vdocuments.us/reader038/viewer/2022100514/577cdb931a28ab9e78a88e2d/html5/thumbnails/5.jpg)
7/28/2019 Micro BBU (6)
http://slidepdf.com/reader/full/micro-bbu-6 5/8
Installation Guide Over Voltage Protection Kit , 351427.033, v1-2005-09 5
4 Connect the green/yellow
earth cable from the top
of the blue OVP unit to
the main grounding point
(copper plate) to the right
side.Torque: 3,0Nm (OVP
unit) and
6.0Nm (copper plate).
Connect the blue cable
from the bottom of the
blue OVP unit to one of
the free connections on
the Neutral mains input
terminal blocks. The
brown cable must be
connected from top of thewhite/orange OVP unit to
one of the free
connections for the Live
mains input terminal
blocks.
Torque: 3.0Nm.
Fix the cables with
straps.
5 The internal OVP kit has
now been installed.
Remount the battery
shelf and the batteries if
they have been removed.
Turn the system on with
the external AC breaker.
282/284
W A GO
281/282
L1
L1
282/284
W A GO
281/282
N N
E
OBO
V25-B+C
OBO
C25-B+C
N-PE
CombiController CombiController
Best.-Nr.5097061 Best.-Nr.5095603
IP20 C E IP20 C E
N
L PE
![Page 6: Micro BBU (6)](https://reader038.vdocuments.us/reader038/viewer/2022100514/577cdb931a28ab9e78a88e2d/html5/thumbnails/6.jpg)
7/28/2019 Micro BBU (6)
http://slidepdf.com/reader/full/micro-bbu-6 6/8
6 Installation Guide Over Voltage Protection Kit , 351427.033, v1-2005-09
![Page 7: Micro BBU (6)](https://reader038.vdocuments.us/reader038/viewer/2022100514/577cdb931a28ab9e78a88e2d/html5/thumbnails/7.jpg)
7/28/2019 Micro BBU (6)
http://slidepdf.com/reader/full/micro-bbu-6 7/8
Installation Guide Over Voltage Protection Kit , 351427.033, v1-2005-09 7
![Page 8: Micro BBU (6)](https://reader038.vdocuments.us/reader038/viewer/2022100514/577cdb931a28ab9e78a88e2d/html5/thumbnails/8.jpg)
7/28/2019 Micro BBU (6)
http://slidepdf.com/reader/full/micro-bbu-6 8/8