mg pricing 1996.pdf - schneider · pdf filemasterpact circuit breakers ... 124 1 long rear...
TRANSCRIPT
Pricing Guide
96
CompactTMand Masterpact" Circuit breakers
GROUPE SCHNElDER Inl "
pricing guide table of contents
page
Compact circuit breakers select~on table 2 Compact CE-100 A 4 Compact CF-250 A 9 Compact CJ-400-600 A 14 Compact CK-800-1200 A 21 Compact CM-1250-2500 A 29
Masterpact circuit breakers select~on table 32 UL L~sted Masterpact MP08 to MP63 34 IEC Rated Masterpact M08 to M63 44 request for quotat~on forms 55
index 61
pricing guide table of contents
page Compact circuit breakers selectton table 2 Compact CE-100 A 4 Compact CF-250 A 9 Compact CJ-40MOO A 14 Compact CK-800-1200 A 21 Compact CM-1250-2500 A 29
Masterpact circuit breakers select~on table 32 UL L~sted Masterpact MP08 to MP63 34 IEC Rated Masterpact M08 to M63 44 request for quotation forms 55
index 61
CompactrM: selection table UL Listed CompactTM circuit breaker
2 Discount Schedule
O 800 A in CKlOOOL and HL drawout version; 1000 A in CK1200 drawout version @ rating 3200 A not UL Listed
CompactTM CE: pricing guide
installation and connection catalog no. term. no. special term. no. list price
cable connection cable lugs on both sides L no charge
rear connection mixed rear connection kit F SR2 $I 90
cons~st~ng of 2 short rear connect~ons 39998 (2) 124
1 long rear connection 39991 (1) 66
plug-in mounting plug-in assembly N-type F BH3 31 8 '--type F BL3 327
conststlng of base@ 38458 200
Plugs N-type 39985 (3) 69 L-type 39992 (3) 78
terrn~nal covers 39983 49
O no trip interlock on 15, 20 and 30 amp ratings
Discount Schedule
Compact'" CE: pricing guide Compact'" CE circuit breaker
complete device catalog number construction
1 2 3 4 5 6 7 8 9 10
1 style 2 termination 3 poles 4 voltage 5 amperage 6 trip 7 aux. switches 8 shunt trip 9 special 10 handle acc. page 8 page 6 page 5 page 6 page 6 function alarm switch undervoltage trip termination motor operators page 7
page 6 page 7 page 7 page 5
Com~act CE with thermal-maanetic t r i ~ unit w
ratina (A) cataloa number list mice " 3 , "
CE104N-480 Vac max.-18kA at 480 Vac 15 CEAL34015 $ 398
100 CEAL34100 471
CE106N-600Y1347 Vac max.-35kA at 480 Vac
100 CEAL36100 565
CE1 O6L -600 Vac max.-100kA at 480 Vac
CElOGNA-molded case switch-600 Vac 100 CEAL36000S 452
cable range: pressure terminals are suitable for copper and aluminum cables:
15-30 A: # I4 AWG (2.5 mm2) to # l o AWG (4 rnmy Cu
II 40-100 A: #8 AWG (10 mm" to #I AWG (50 mm7) Cu or 418 AWG (1 0 mmy to #I10 AWG (50 mm2) Al
interrupting ratings: page 2 technical manual: AC012111 E
Discount Schedule
CompactTM CE: pricing guide
accessories r for factory-tnstalled accessories complete the ctrcult breaker catalog number by inserttng the opt~on number in the appropriate block * far field-lnstallable accessortes order the 5-dlgtt catalog number
A- - volts (V) cataloa no. ootion no. list orice
~lectrical accessories auxiliary and alarm switchesa 1 auxiliary switch (OF) 38401 A1 $156
2 aux~l~ary sw~tches (OF) 38401 (2) A2 31 2
1 alarm switch (SD) 38402 B1 156
1 auxiliary (OF) and I alarm switch (SD) 38401 + 38402 AB 312
2 alarm switches 1SD) 38402 12) 82 31 2
125 38438 SR 382
MN (undervoltage trip)O AC 60 Hz 120 38420 U A 382
motor oneratot@
CompactTM CE: pricing guide
consistina of Compact CE with thermal-magnetic trip unit rating (A) cable connection style voltage trip function list price
CE104N-480 Vac max.-18kA at 480 Vac 15 381 13-01 5 CEA 4 $ 398 20 381 13-020 CEA 4 398
30 381 13-030 CEA 4 398
40 381 13-040 CEA 4 398
45 381 13-045 CE A 4 398 50 381 13-050 CEA 4 398 - --- 60 381 13-060 CEA 4 398
70 381 13-070 CEA 4 471 .. . 80 381 13-080 CE A 4 471
90 381 13-090 CEA 4 471
100 381 13-100 CE A 4 471
CE106N-600Yl347 Vac max.-35kA at 480 Vac 15 38033-01 5 CEA 6 477
20 38033-020 CEA 6 477 30 38033-030 CE A 6 477 40 38033-040 CEA 6 477 45 38033-045 CEA 6 477
50 38033-050 CEA 6 477
60 38033-060 CEA 6 477
70 38033-070 CEA 6 565
80 38033-080 CEA 6 565 90 38033-090 CEA 6 565
100 38033-1 00 CE A 6 565
CE106L-600 Vac max.-100kA at 480 Vac 15 38073-01 5 CEI 6 1051
20 38073-020 CEI 6 1051 30 38073-030 CEI 6 1051
40 38073-040 CEI 6 1051
45 38073-045 CEI 6 1051
50 38073-050 CEI 6 1051 60 38073-060 CEI 6 1051 70 38073-070 CEI 6 1240
80 38073-080 CEI 6 1240 90 38073-090 CEI 6 1240
100 38073-1 00 CEI 6 1240
CE1 O6NA-molded case switch-600 Vac 100 38093 CEA 6 S 452
6 Discount Schedule
CompactTM CF: pricing guide CompactTM CF circuit breaker
complete device catalog number construction
1 2 3 4 5 6 7 8 9 10 11 12 I U U U I I U U i i U I ~ 1 style 2 termination 3 poles 4 voltage 5 amperage 6 trip function
page 1 1 page 10 Page 9 page 11 page 11
7 aux. switches 8 overcurrent trip 9 shunt trip 10 secondary 11 special 12 handle accessories page 13 alarm switch switch undervoltage trip disconnects termination motor operators page 12 page 12 page 12 page I 2 page 12 page 10
cable range: pressure terminals are suitable for copper and aluminum cables: m 15-30 A: #I4 AWG (2.5 mm2) to
# I 0 AWG (4 mmz) Cu 40-100 A: #8 AWG (I0 mm2) to # I AWG (50 mmz) Cu or #8 AWG ( I 0 mm2) to #If0 AWG (50 mm2) Al
interrupting capability: page 2 technical manual: AC0121/1 E
Compact CF with thermal-magnetic trip unit - rating (A) busbar connection list price cable connection list price
CF250N 600Yl347 Vac max.-35kA at 480 Vac 70 CFAF36070 $1155 CFAL36070 $1255 90 CFAF36090 11 55 CFAL36090 1255
100 CFAF36100 11 55 CFAL36100 1255 125 CFAF36125 1155 CFAL36125 1255 150 CFAF36150 1155 CFAL36150 1255 175 CFAF36175 1155 CFAL36175 1255 200 CFAF36200 1155 CFAL36200 1255 225 CFAF36225 1155 CFAL36225 1255 250 CFAF36250 1987 CFAL36250 2087
CF250H-600Y1347 Vac max.-42kA at 480 Vac 70 CFHF36070 1501 CFHL36070 1601 90 CFHF36090 1501 CFHL36090 1601
100 CFHF36100 1501 CFHL36100 1601 125 CFHF36125 1501 CFHL36125 1601 150 CFHF36150 1501 CFHL36150 1601 175 CFHF36175 1501 CFHL36175 1601 200 CFHF36200 1501 CFHL36200 1601 225 CFHF36225 1501 CFHL36225 1601 250 CFHF36250 2584 CFHL36250 2684
CF250L-600 Vac max.-150kA at 480 Vac 70 CFIF3607OF 2872 CFlL3607OF 2972 90 CFIF3609OF 2872 CFlL3609OF 2972
100 CFIF361OOF 2872 CFlL361OOF 2972 125 CFIF36125F 2872 CFlL36125F 2972 150 CFIF3615OF 2872 CFIL3615OF 2972 175 CFIF36175F 2872 CFIL36175F 2972 200 CFIF3620OF 2872 CFIL362OOF 2972 225 CFIF36225F 2872 CFIL36225F 2972 250 CFIF3625OF 3963 CFIL3625OF 4063
rear connection list price plug-in list price
70 CFIF36070R $3180 CFIF36070 $3034 90 CFIF36090R 31 80 CFIF36090 3034
100 CFIF36100R 3180 CFIF36100 3034 125 CFIF36125R 3180 CFIF36125 3034 150 CFIF36150R 3180 CFIF36150 3034 175 CFIF36175R 3180 CFIF36175 3034 200 CFIF36200R 3180 CFIF36200 3034 225 CFIF36225R 3180 CFIF36225 3034 250 CFIF36250R 4268 CFIF36250 4124
CF25OHC-for motor circuit protection-600Yl347 Vac 150 CFHF36150M 1155 CFHL36150M 1254 250 CFHF36250M 1987 CFHL36250M 2086
CF25ONA-molded case switch-600 Vac
CompactTM CE: pricing guide
accessories - Continued 8 for factory-installed accessories complete the circuit breaker catalog number by inserting the option number in the appropriate block 8 for field-installable accessories order the 5-digit catalog number
catalog no. handle list price option no.
rotary handles directly mounted standard w~th black toggle 39980 RO $ 78
MCC type 39979 110
door mounted
rear door long shaft (=39980+42897) 39954 246
locks, interlocking padlocking and locking devices
of the handle (In OFF pos~t~on)
by 3 padlocks (not suppl~ed) 44936 PL 29 by 1 key IockO rnount~ng k~ t 35636 LK 144
rnountlng kit and 35636 + KK 844 key ~nterlock 35635-F
key ~nterlock only 35635-F 700
of the rotary handle (CII n OFF pos~t~on)
by 3 padlocks (not suppl bu~lt ~n
by 1 key lock : 1351 500 41 940 101
cuit breaker i
ied)
W
mechanical interlockina (for fixed circuit breakers with rotarv handle)
mechan~cal device (rotary operating handles not included) 44826 388
key locks interlocking (for f~xed clrcurt breakers w~th rotary handle)
1 set of 2 key locks Ron~s 1351 500 41 950 206 (keyed al~ke)
installation accessories door escutcheon for door cutout 42977 21
@ handle rubber boot
sealing accessories
F for trip unlt and cover ( I set) 39970 16
circuit label-holder
set of 10 42976 36
spare parts black handle for rotary operating handle
42875 43
- factory-mounted only
8 Discount Schedule
CompactTM CF: pricing guide
consistina of Compact CF with thermal-magnetic trip units rating (A) busbar connection style trip function list price
CF250N-600Y1347 Vac max.--35kA at 480 Vac 70 37026-070 CFA $1155 90 37026-090 CFA 1155
100 37026-1 00 CFA 1155
125 37026-1 25 CFA 1155
150 37026-1 50 CFA 1155 175 37026-1 75 CFA 1155
200 37026-200 CFA 1155
225 37026-225 CFA 1155 250 37026-250 CFA 1987
CF250H-600Yl347 Vac max.-42kA at 480 \, 70 37028-070 CFH 1501
90 37028-090 CFH 1501
100 37028-1 00 CFH 1501 125 37028-125 CFH 1501
150 37028-1 50 CFH 1501 175 37028-1 75 CFH 1501
200 37028-200 CFH 1501 225 37028-225 CFH 1501
250 37028-250 CFH 2584
CF250L-600 Vac max.-150kA at 480 Vac 70 37029-070 CFI 2872
90 37029-090 CFI 2872
100 37029-1 00 CFI 2872 125 37029-1 25 CFI 2872
150 37029-1 50 CFI 2872 175 37029-1 75 CFI 2872
200 37029-200 CFI 2872 225 37029-225 CFI 2872 250 37029-250 CFI 3963
rear connection
70 37030-070 CFI 3180
90 37030-090 CFI 31 80 100 37030-1 00 CFI 31 80 125 37030-1 25 CFI 31 80
150 37030-1 50 CFI 31 80
175 37030-1 75 CFI 31 80 200 37030-200 CFI 3180 225 37030-225 CFi 3180
250 37030-250 CFI 4268
plug-inO
70 37031 -070 CFI 3034 90 37031 -090 CFI 3034
100 37031 -1 00 CFI 3034
125 37031-125 CFI 3034 150 37031-1 50 CFI 3034
175 37031 -175 CFI 3034 200 37031 -200 CFI 3034
225 37031 -225 CFI 3034 250 37031 -250 CFI 41 24 -
CF250HC for motor circuit protection-600Yl347 Vac 150 37032-1 50 CFH M 1155 - ~
250 37032-250 CFH M 1987
CF250NA-molded case switch-600 Vac 250 37034 CFA S 1096
O without plug-in base, w~th plugs
Discount 11
Schedule
@ 60i75"C wlres for ratings 125 A and less a consult factory for other available optlons @ suppl~ed wlth the circuit breaker
10 Discount Schedule
Csmpacl'" CF: pricing guide
accessories f o r factory-installed accessories complete the circuit breaker catalog number by inserting the option number in the appropriate block = for field-installable accessories order the 5-digit catalog number
volts (V) catalog no. option no. list price
electrical accessories auxiliary and alarm switches 2 auxiliary switches (0F)O 37402 A2 $ 287 1 auxiliary (OF) and 1 alarm switch (SD)O 37401 AB 203
1 overcurrent trip switchO 37403 AT 81
shunt trip and undervoltage trip MX (shunt trip) O AC60Hz 120 37437 S A 382
240 37446 SC 382 480 37447 SH 382
DC 12 37434 SN 382 24 37435 SO 382 48 37436 SP 382
125 37437 SR 382
48 3741 1 UP 382 125 3741 2 UR 382
motor oDerator ~~ --
standard type AC60 Hz 120 37464 MA 1502 240 37465 MC 1502
DC 24 37460 MO 1502 48 37461 MP 1502
125 37462 MR 1502
secondary disconnecting blocks moving part 3 terminals@ 36693 DO 23 - .
6 terminals8 36696 DO 34
fixed part 3 terminals@ 42940 DO 23
6 terminals8 42941 DO 34
6 A (auxiliary), 5 A (alarm) at 480 Vac; 3 A at 600 Vac; 0.5 A at 125 Vdc; 0.25 A at 250 Vdc O factory-mounted Continued On next page @ minimum voltage 55% of rated voltage in ac and 75% of rated voltage in dc @ dropout at 3570% of rated voltaae. D ~ C ~ U D at 85% of rated voltaoe @ 3 wires are needed for shunt trip or iinde~oltage trip 6 6 ares are needed for a ~ x ~ l ~ a r y sw tches or motor operator 'Z optlon D' Inserted In block 10 w II supp y both rnovtng and ftxed parts on a e ectrlcal accessories nstal ed
12 Discount Schedule
CompactTM CJ: pricing guide
complete device Compact CJ with electronic trip unit and full ampere rating plug trip unit type rating (A) busbar connection list price cable connection list price
CJ400N-35kA at 480 Vac ST1 14D 400 CJAEF36404LI $2463 CJAEL36404LI $2643
ST214S 400 CJAEF36404LS 3539 CJAEL36404LS 371 9
CJGOON-35kA at 480 Vac ST1 14D 600 CJAEF36606LI 3869 CJAEL36606LI 4113 ST21 4s 600 CJAEF36606LS 4913 CJAEL36606LS 51 57
CJ400H-42kA at 480Vac ST1 14D 400 CJHEF36404LI 3103 CJHEL36404LI 3283
ST21 4s 400 CJHEF36404LS 4178 CJHEL36404LS 4358
CJ600H-42kA at 480 Vac
CJ40OL-150kA at 480 Vac ST1 14D 400 CJIEF36404LI 4597 CJIEL36404L
Discount Schedule
5 amperage 6 trip function
10 secondary disconnects 11 special termination 12 handle accessories page 20 undervoltage trip page I 9 page I 6 motor operators page 19 page 19
Compact CJ with thermal-magnetic trip unit rating (A) busbar connection list price cable connection list price
CJ400N-35kA at 480 Vac 250 CJAF36254 $2137 CJAL36254 $231 7 300 CJAF36304 21 37 CJAL36304 231 7 350 CJAF36354 21 37 CJAL36354 2317 400 CJAF36404 2137 CJAL36404 231 7
CJ600N-35kA at 480 Vac 350 CJAF36356 3537 CJAL36356 3781 400 CJAF36406 3537 CJAL36406 3781 450 CJAF36456 3537 CJAL36456 3781 500 CJAF36506 3537 CJAL36506 3781 600 CJAF36606 3537 CJAL36606 3781
CJ400H -42kA at 480 Vac 250 CJHF36254 2775 CJHL36254 2955 300 CJHF36304 2775 CJHL36304 2955 350 CJHF36354 2775 CJHL36354 2955 400 CJHF36404 2775 CJHL36404 2955
CJ600H-42kA at 480 Vac 350 CJHF36356 4592 CJHL36356 4836 400 CJHF36406 4592 CJHL36406 4836 450 CJHF36456 4592 CJHL36456 4836 500 CJHF36506 4592 CJHL36506 4836 600 CJHF36606 4592 CJHL36606 4836
CJ400L- 150kA at 480 Vac
300 CJIF36304 4268 CJIL36304 4448 350 CJIF36354 4268 C.III 363.54 M A R
-
400 CJIF36404 4268 CJIL36404 4448
CJ4001600HC for motor circuit ~rotection
CJ4001600NA molded case switch
cable range: pressure terminals are suitable for copper and aluminum cables:
400 A terminal: 1 cable: #210 AWG (70 mmz) to 600 kcmil(300 mm" Cu or 1 cable: #4/0 AWG (95 mm2) to 500 kcmil (240 mm') Al
= 600 A terminal: 1 cable: #2/0 AWG (70 mm" to 500 kcmil (240 mm" Cu or 1 to 2 cables: #2/0 AWG (70 mm') to 350 kcmil (185 mm" Cu or 1 to 2 cables: #4/0 AWG (95 mm2) to 500 kcmil (240 mm') Al
interrupting capability: page 3 technical manual: AC0060/1 E
14 Discount Schedule
CompactTM CJ: pricing guide
Compact CJ with thermal-magnetic trip unit rating (A) busbar connection style trip function list price
CJ400N-35kA at 480 Vac 250 36053-250 CJA $21 37
300 36053-300 CJA 21 37 350 36053-350 CJA 2137
400 36053-400 CJA 21 37
CJ600N-35kA at 480 Vac 350 36054-350 CJA 3537
400 36054-400 CJA 3537
450 36054-450 CJA 3537
500 36054-500 CJA 3537 600 36054-600 CJA 3537
CJ400H-42kA at 480 Vac 250 36057-250 CJH 2775 300 36057-300 CJH 2775
350 36057-350 CJH 2775 4nn 36057-400 CJH 2775
62
e switch
CompactTM CJ: pricing guide
installation and connection catalog no. term. no. special term no. list price
busbar connection connections screws 36703 (2) F no charge
cable connection 400 A lugs-(I) #2/0 AWG (70 mm2) to 600 kcmil (300 mm2) Cu or #4/0 AWG (95 mm2) to 500 kcmil (240 mm2) A1
field-installable one side 36699 $ 90
factory-mounted both sides 36747 L 180
line side only 36748 M 90
load s~de only 36749 P 90
600 A lugs-(I) #a0 AWG (70 mm2) to 500 kcmil (240 mm2) Cu or (I) to (2) #a0 AWG (70 mmz) to 350 kcmil (185 mm2) Cu or ( I ) to (2) #4/0 AWG (95 mm2) to 500 kcmil (240 mm2) Al
field-installable one side 36702 122
factory-mounted both sides 36737 LO 244
line side onlv 36738 MO 122
load side only 36739 PO 122
rear connection mixed rear connection kit F 61 2
consisting of N- and H-type 36704 (2) SRLO 61 2
type 36705 (2) LRLO 61 2 plug-in mounting plug-in assembly N- and H-type F BH3 805
L-type F BL3 946 consistina of base 36698 538
6) for CJ400 insert PT1 in block 11 Oconsult factory for other available options
16 Discount Schedule
CompactTM CJ: pricing guide
accessories for factorv-installed accessories complete the circuit breaker catalog number by inserting the option number in the appropriate block for field-iktallable accessories ordeithe 5-digit catalog number
-
volts (V) catalog no. option no. list price
electrical accessories auxiliary and alarm switches 1 a u x ~ l ~ a r y (OF) and 1 alarm (SD)O 36405 AB $ 203
3 a u x ~ l ~ a r y (OF) and 1 alarm switch (SD)O 36402 A3 552
2 auxil~ary switches ( 0 F ) O 36404 A2 287
1 overcurrent t r ~ p sw~tchO 37403 AT 81
shunt trip and undervoltage trip MX (shunt trip) O
motor operator standard type
secondary disconnecti moving part 3 term. 366930
6 term. 366960 D O 34
fixed part 3 term. 4
6 term. 42941@ D O 3 4
O 6 A (auxiliary), 5 A (alarm) at 480 Vac; 3 A at 600 Vac; 0.5 A at 125 Vdc; 0.25 A at 250 Vdc O factory-mounted Continued On next page O minimum voltage 55% of rated voltage in ac, and 75% of rated voltage in dc @drop out at 3570% of rated voltage, pickup at 85% of rated voltage 0 3 wires are needed for shunt t r i ~ or u n d e ~ o l t a ~ e t r i ~ '5 6 w res are needed for aux a{ swlches or mGor dperator ! opt on 'I3 Inserted In blocn 10 w~ll s ~ p p y 00th mov ng and fixed parts for a I electr~cal accessories ~nstalled
Discount Schedule
CompactTM CJ: pricing guide
ST114D 600 36058-1 14 CJH LI 481 5
ST21 4s 600 36058-21 4 CJH LS 5860
CJ400L-150kA at 480 Vac ~- ~-~ -----..-
ST1 14D 400 36060-1 14 CJI LI 4488 ST21 4s 400 36060-21 4 CJI LS 5562
+ rating plug CJ400 200 36201 204 109
225 36202 224 109
250 36203 254 109
300 36204 304 109 350 36205 354 I ncl
18 Discount Schedule
CompactTM CK: pricing guide CompactTM CK circuit breaker
complete device catalog number construction
1 2 3 4 5 6 7 8 9 10 11 12 13 I u u u I I I I u - - u ~ ~ u 1 style 2 termination 3 poles 4 voltage 5 amperage 6 trip function
page 24 pages22-23 6: 600 Vac page 24 page 24
7 aux. switches 8 overcurrent trip 9 shunt trip 10 secondary 11 special 12 handle accessories page 27 13 drawout alarm switch switch undervoltage trip disconnects termination motor operators page 26 option page 26 page 26 page 26 page 26 pages 22-23 page 23
Compact CK with STR25DP trip unit and full ampere rating plug rating (A) busbar connection list price cable connection list price
CK400/800/1 SOON-standard rated-50kA at 480 Vac CK400N 400 CKAXF36404LI $ 4460 CKAXL36404LI $ 4731
CK800N 800 CKAXF36808LI 4460 CKAXL36808LI 4731
CK1200N 1200 CKAXF36121 LI 7748 CKAXL36121 LI 8061
CK400/80011200NN-100% rated-50kA at 480 Vac CK400NN 400 CKAEF36404LI 4910 CKAEL36404LI 5181
CK800NN 800 CKAEF36808LI 4910 CKAEL36808LI 5181
CK1200NNO 1200 CKAEF36121 LIERL 9254
CK400/800/1000/12OOH-standard rated-65kA at 480 Vac CK400H 400 CKHXF36404LI 5366 CKHXL36404LI 5637
CK800H 800 CKHXF36808LI 5366 CKHXL36808LI 5637
CKIOOOHLO 1000 CKIXF36100LI 13692 CKIXL36100LI 1401 2
CK1200H 1200 CKHXF36121 LI 8657 CKHXL36121 LI 8977
CK400/800/1200HH-100% rated-65kA at 480 Vac CK400HH 400 CKHEF36404LI 5996 CKHEL36404LI 6267
CK800HH 800 CKHEF36808LI 5996 CKHEL36808LI 6267 CK1200HHO 1200 CKHEF36121 LlERL 10275
CK1 000L-standard rated-480 Vac max.-150kA at 480 Vac CKl OOOL 1000 CKIXF34100LI 13692 CKIXL34100LI 1401 2
CK80011200NA molded case switch CK800NA 800 CKAF36008S 3488 CKAL36008S 3759
CK1200NA 1200 CKAF36001 S 5538 CKAL36001 S 5858 O edaewlse rear connectors are mandatory for lhne and load Not available for cable connected O I 56kn at 480 Vac
cable range: pressure terminals are suitable for copper and aluminum cables: s 800 A terminal:
1 to 2 cables: #2/0 AWG (70 mm2) to 400 kcmil (185 mm2) Cu or 1 to 3 cables: #2/0 AWG (70 mm2) to 300 kcmil (150 mm2) Cu or 1 to 3 cables: #4/0 AWG (95 mm2) to 400 kcmil (1 85 mm2) Al 1200 A terminals:
1 to 4 cables: #3/0 to 500 kcmil (240 mm2) Cu or 1 to 4 cables: #4/0 AWG (95 mm2) to 500 kcmil (240 mm2) Al 1 to 3 cables: 250 to 600 kcmil (300 mm2) Cu
interrupting capability: page 3 technical manual: AC003712E
CompactTM CJ: pricing guide
accessories -Continued for factory-installed accessories complete the circuit breaker catalog number by inserting the option number in the appropriate block for field-installable accessories order the &digit catalog number
catalog no. handle list price option no.
rotary handles directly mounted
Q standard wlth black toggle 44820 RO $200
separate red toggle 44847 49
door mounted rear door (=44820+42897) 44840 368
locks, interlocking padlocking and locking devices of the handle (In OFF poslt~on)
by 3 padlocks (padlocks not suppl~ed) 44936 PL 29
key interlock O rnount~ng k ~ t 35636 LK 144
key ~nterlock and 35635-F + KK 844 mountlng k ~ t 35636
key ~nterlock only 35635-F 700
of the rotary operating handle (c~rcuit breaker In OFF position)
by 3 padlocks (padlocks not suppl~ed) bu~lt in
by key lock Ron~s 1351 500 41 940 103
mechanical interlocking (for use with 2 directly mounted rotary handles)
CE to CJ frame 44826 388
key locks interlocking (for fixed circuit breakers with rotary handle)
1 set of 2 key locks Ronls 1351.500 41 950 206 (keyed alike)
- . installation accessories door escutcheons
for door cutout for handle 44938 23
for motor operator 43745 160
handle rubber boot
sealina accessories
circuit label-holder
@ set of 10 42976 36
spare parts handle extension 44964 32 0
black toggle for rotary operating handle 44846 61
20 Discount Schedule
CompactTM CK: pricing guide
installation and connection-continued catalog no. term. no. special drawout list price
term. no. option
standard chassis flat connection N/H 46423 D F DO0 $2337
HUL 46429 D F DO@ 2337 cons~st~ng of complete chass~s NIH 46851 1658
HUL 46852 1658
plugs N/H 46896 (3) 255
HUL 46915 (3) 255
terrn~nal cover 46993 (2) 148
rear connections 46990 (6) 21 0
edgewise connection N/H 46425 D E DO0 2337 HUL 46431 D E DO@ 2337
consrstlng of complete chassis NIH 46851 1658
LH/L 46852 1658
plugs N/H 46896 (3) 255 HUL 46915 (3) 255
terrnlnal cover 46993 (2) 148
rear connections 46988 (6) 276
universal chassis flat connection NIH 46423 D F DUO 2975 HUL 46429 D F DUO 2975
cons~st~ng of rnovlng chass~s 46824 440
fixed chass~s N/H 46820 1922 HUL 46822 1922
plugs N/H 46896 (3) 255
HUL 46915 (3) 255
terrn~nal cover 46993 (2) 148 rear connections 46990 (6) 21 0
edgewise connection NIH 46425 D E DUO 3041
HUL 46431 D E DUO 3041
conslstlng of rnovfng chass~s 46824 440
f~xed chassls N/H 46820 1922
LHIL 46822 1922
plugs N/H 46896 (3) 255 HUL 46915 (3) 255
terminal cover 46993 (2) 148
rear connections 46988 (6) 276 O consult factory for other ava~lable optlons
Discount Schedule
CompactTM CK: pricing guide
installation and connection catalog no. term. no. special drawout list orice
term. no. option
busbar connection connection screws and terminal cover 35626 (2) F no charge
cable connection 800 A lugs-(3) #2/0 AWG (70 mm2)-300 kcrnil(150 mm2) for CK400 and CK800
field-installable one side 46961 $ 136 factory-mounted both sides 35637 L 272
line side only 35638 M 136 load side only 35639 P 136
1200 A lugs-(4) #4/0 AWG (95 mmz)-500 kcmil(240 mrn2) for CK1000 and CK1200
field-installable one side 46960 160 factow-mounted both sides 35627 I m 29n ...- -- ---
line side only 35628 MO 160 load side onlv 35629 PO ifin - - . -"
optional 1200 A lugs-(3) 250-600 kcm~l (12&300 mrn2) f~eld-lnstallable one srde 46966 160 factory-mounted both s~des 3561 7 LO 320
line s~de onlv 3561 8 MO 1 6n . -- load srde only 35619 PO 160
rear connection flat NIH 46415 F FRLO .a4 - -
L 4641 7 F FRLO 760 conslstlng of rear connectors NIH 46958 (6) 396
HUL 46916 (6) 612 termlnal cover 46993 (2) 148
edgewise N/H 46415 F ERLO 544 L 46419 F ERLO 844
conslstlng of rear connectors N/H 46958 (6) 396 HUL 46913 (6) 696
termrnal cover 46993 (2) 148 @ for CK400 or CK800 Insert PT1 in block 11 O for CK400, CK800 or CK1200 insert PT2 in block 11 @ consun factory for other ava~lable options
Continued on next page
22 Discount Schedule
CompactTM CK: pricing guide
consisting of-continued + rating plug rating (A) catalog no. amperage no. list price CK400
+ external neutral sensor ground-fault protection for 3PH4W system 400 35700 720
1200 35703 720 0 cannot be used in a drawout assembly
CompactTM CK: pricing guide
consisting of Compact CK basic frame
busbar connection style trip function list price
CK400/800/1 SOON-standard rated-50kA at 480 Vac CK4OON 35028 CKAX $ 2250
CK800N 35029 CKAX 2250
CK1200N 35030 CKAX 5538
CK400/800/1200NN-100% rated-50kA at 480 Vac CK400NN-100% rated 35038 CKAE 2700
CK800NN-100% rated 35039 CKAE 2700
CK1200NN-100% rated 350400 CKAE 6648
CK400/800/1000/1200H-standard rated-65kA at 480 Vac CK400H 35031 CKHX 3156
CK800H 35032 CKHX 3156
CKIOOOHL 35034 CKlX 11482
CK1200H 35033 CKHX 6447
CK400/800/1200HH-100% rated-65kA at 480 Vac CK400HH-100% rated 35041 CKHE 3786
CK800HH-100% rated 35042 CKHE 3786
CK1200HH-100% rated 350430 CKHE 7669
CK1 000L-standard rated-480 Vac-150kA at 480 Vac CKl OOOL 35035 CKlX 11482
CK80011200NA molded case switch CK800NA 35026 CKA 3488
CK1200NA 35027 CKA 5538
+ electronic trip unit long-timeo, and instantaneous protection STR25DP 35400 LI 21 01
long-timeo, short-time and instantaneous protection STR45SP 35407 LS 3380
long-timeo, short-time, instantaneous protection and options STR55UP T 3541 3 L2 4393
STR55UP RF 3541 6 L3 5086
STR55UP TRF 35417 L4 61 00
STR55UP FC 35420 L5 3947
STR55UP RFC 35422 L7 5086 ~~~
STR55UP TFC 35424 L6 4948
STR55UP TRFC 35425 L8 61 00 0 edgewise rear connectors are mandatory for line and load a LT off: can be defeated by using LT off rating plug cat. no. 35300 @cannot be used in a drawout assembly
summary of options: C: communication with DialpacP R: load monitoring F: fault indicators powered by 24 to 240 Vac or Vdc external source T: residual type ground-fault protection
Continued on next page
24 Discount Schedule
CompactTM CK: pricing guide
accessories - Continued a for factory-installed accessories complete the circuit breaker catalog number by inserting the option number in the appropriate block a for field-installable accessories order the 5-digit catalog number
catalog no. option no. list price
rotary operating handles directly mounted standard wlth black toggle 46933 RO $253
door mounted rear door (=46933+42897) 46872 434
locks, interlocking padlocking and locking devices
of the handle (in OFF position)
by 3 padlocks (padlocks not supplied) 44936 PL 29 bv kev lock mountina kit@ 35636 LK 144
mounting kit and 35636 + KK 844 key interlock 35635-F
key interlock only 35635-F 700
of the rotary operating handle (circuit breaker in OFF position)
by 3 padlocks (not supplied) built-in
1 key lock Ronis 1351.500 41 940 103
drawout assembly locking by 3 padlocks (padlocks not supplied) bullt-ln
locklng dev~ce for 1 or 2 key locks (key lock not supplied) 46836 129
key lock for locklng In disconnected posltlon 35635 472
door Interlock, connected posltlon locklng devlce 46834 141
racklng Interlock locklng devlce 46835 103
mechanical interlocking (for flxed clrcult breakers wlth rotary handle)
mechan~cal devlce (rotary operating handles not ~ncluded) 46946 545
mechanical interlocking (for fixed circuit breakers with rotary handle)
%S I set of 2 key locks (keyed alike) Ronis 1351.500 41 950 206
@ factory-mounted only Continued on next page
Discount 27
Schedule
CompactTM CK: pricing guide
accessories for factory-installed accessories complete the circuit breaker catalog number bv inserting the option number in the appropriate block . . . for field-installable accessories orderthe 5-digit catalog number
-
volts (V) catalog no. option no. list price
electrical accessories auxiliary and alarm switch
1 auxlllary (OF) + 1 alarm (SD) swltch O 36405 AB $ 203
3 auxll~ary (OF) + I alarm (SD) swltch O 36402 A3 552
2 auxlllary (OF) swltches O 36404 A2 287
overcurrent tr~p swltch SDE O 36403 AT 161 position switches 1 connected 46963 222 for drawout onlyO 1 disconnected 46964 222
shunt trip and undervoltage trip
MX (shunt trip)@ AC60Hz 120 36437 S A 382
240 36446 SC 382
480 36446 SH 382
DC 12 36434 SN 382
24 36435 SO 382
MN (undervoltage trip)@ AC 60 Hz 120 3641 8 U A 382
240 3641 9 UC 382
motor operator
standard type AC6OHz 120 35678 MA $2651
240 35679 MC 2651
DC 12 35670 MO 2651
24 35671 MP 2651
125 35672 MR 2651
locking device for Ronis key lock 1351 500 (lock not 44876 120 supplied, cannot be fitted on automatic transfer switch)
1 Ronis key lock 1351.500 41945 103
secondary disconnecting blocks
moving part 3 term.@ 36693 D@ 23
6 terrn.O 36696 D@ 34
fixed part 3 term.@ 42940 D@ 23
6 terrn.O 42941 D@ 34
test kits
battery operated (battery not ~ncluded) 43362 483
portable test kit 120 55391 8950
6 A (auxiliary), 5 A (alarm) at 480Vac; 3 A at 600 Vac; 0.5 A at 125 Vdc, 0.25 A at 250 Vdc 2 A at Z ~ O V ~ C , o . 1 ~ at 125 V ~ C . ~actory-mounted Continued on next page 6 A at 480 Vac, 3 A at 600 Vac, 0.5 A at 125 Vdc, 0.25 A at 250 Vdc
@ minimum operating voltage 55% of rated voltage In ac and 75% of rated voltage in dc @dropout at 3570% of rated voltage, pickup at 85% of rated voltage @ 3 wires are needed for shunt trip or undervoltaqe trip '? 6 w res are needed for auxl ary swtcnes or motor operator 3 opl~on D nsened n olock 10 wll supply ooln mod ng ano I xed pans for all electr cal accessories ~nstalled
26 Discount Schedule
CompactTM CM: pricing guide CompactTM CM circuit breaker
complete device catalog number construction
1 2 3 4 5 6 7 8 9 10
1 style 2 termination 3 poles 4 voltage 5 amperage 6 trip 7 aux. switches 8 shunt trip 9 special 10 handle acc. page 31 page 29 F: busbar 6: 600 Vac page 29 function alarm switch undervoltage trip termination motor operators page 31
page 30 page 31 page 31
A Com~act CM with ST206D t r i ~ unit rating (A) catalog no. list price
standard rated-85kA at 480 Vac
100% rated-85kA at 480 Vac CM1250HH 1250 CMEF36126LI 10064
-. .- - .
CM2500HH 2500 CMEF36250LI 201 63
molded case switch
CM2500HA 2500 CMAF36025S 17209 note: CM3200 circuit breaker or switch (IEC rated, not UL Listed) is available with 3200 A rating. Consult factory for pricing.
interrupting capability: page 3 technical manual: AC0036llE
CompactTM CK: pricing guide
accessories- Continued for factory-installed accessories complete the circuit breaker catalog number by inserting the option number in the appropriate block
a for field-installable accessories order the 5-diait cataloa number
cataloa no. odion no. list orice ., installation accessories door cutout escutcheons
for f~xed mountlng of clrcult breaker 44938 $ 23 escutcheon wlth handle extens~on (IP 40). 46977 249 for wtthdrawable devlce wrthout mGor operator
accessories for drawout assembly door frame around racklng rnechan~sm 46830 103
around handle 46831 207
around rotary handle 46832 289 secondary disconnect~ng block cover 39967 41
drawout shutters
on fixed chassis (1 ~ iece) 46987 (6) 540
sealing accessories for t r~p unlt 46939 71 for cover 44937 34
circuit label-holder set of 10 42976 36
extended handle
A standard 46998 20 long for extended escutcheon (drawout mounttng) 46996 20
toggle
9 for rotary handle black 46970 68
red 46971 68
28 Discount Schedule
CompactTM CM: pricing guide
accessories w for factory-installed accessories complete the circuit breaker catalog number by inserting the option number in the appropriate block
for field-installable accessories order the 5-digit catalog number volts (V) catalog no. options list price
connection accessories connectors 2000 A (3) 55797 $ 666 2000 A (6) 55798 1331 2500 A (6) 55799 301 5 connectors are mandatory for line and load prices are given for replacement only
electrical accessories
4 auxiliary switch (OF) + 1 alarm switch (SD)O 55754 A4 966 overcurrent trip switch@ standard
shunt trip and undervoltage trip
MX (shunt tr~p)O AC 60 Hz 120 55740 SA 571 240 55741 SC 571 480 55742 SH 571
DC 24 55744 SO 571
MN (undervoltage trip)@ AC 60 Hz 120 55728 UA 571
motor operator@@ AC 60 Hz 120 5561 1 MA 5593
240 55613 MC 5593 277 55615 MD 5593 480 5561 7 MH 5593
DC 24 55618 MO 5593 48 55620 MP 5593
locks locking device by 3 padlocks (not suppl~ed) 55653 PL 128 by key lock mountlng k~ t 8 55768 LK 149
mountlnq k~ t and 55768 + KK 621 key ~nteriock 35635
key ~nterlock only 35635 472
spare parts operating handle 55661 46
extended toggle 55662 64
6) 6 A (auxiliary), 5 A (alarm) at 480Vac; 3 A at 600Vac; 0.5 A at 125 Vdc; 0.25 A at 250 Vdc @ minimum operating voltage 55% of rated voltage in ac and 75% of rated voltage in dc O dropout at 3570% of rated voltage, pickup at 85% of rated voltage @ 2 A at 240 Vac and 0.1 A at 125 Vdc @ not UL Listed. Includes 4 auxiliary and I alarm switch #55676: factory-mounted only 8 factory-mounted only
Discount 31
Schedule
Compact CM basic frame busbar connection style trip function list price
standard rated-85kA at 480 Vac CM1250HE 55809 CMX $ 6985 CM1600HE 55808 CMX 7628 CM2000HE 558070 CMX 91 27 CM2500HE 558060 CMX 161 66
100% rated-85kA at 480 Vac CM1250HH 55804 CME 7683 CM1600HH 55803 CME 8391 CM2000HH 558020 CME 10038 CM2500HH 558010 CME 17782
molded case switch-trip unit not required CM1600HA 55791 CMA 7628 CM2000HA 55792 CMA 9128 CM2500HA 55793 CMA 17209
+ electronic trip unit long-time and instantaneous protection ST206D 55722 LI $2381
long-time, short-time and instantaneous protection ST306S 55723 LS 3475
long-time, short-time, instantaneous protection and ground-fault protection ST306ST ( I 250-2000 A) 55724 L2 4559 ST31 6ST (2500 A) 55725 L2 4559
+ external neutral sensor ground-fault protection for 3PH4W system for CM1250 55760 840 for CM1600 55759 840 for CM2000 55758 840 for CM2500 55757 840
0 rear connectors are ~ncluded
30 Discount Schedule
sales offices in the United States
Alabama Birmingham ................ (205) 967-1 110 Dothan ........................ (205) 793-21 77 Huntsville .................... (205) 539-2465 Mobile ....................... (205) 342-7747 Montgomery ............... (205) 271-0230
Alaska Anchorage .................. (907) 278-6048
Arizona Phoenix ...................... (602) 231 -8694 Tucson ........................ (602) 577-0480
Arkansas Little Rock .................. (501) 225-3648 Springdale .................. (501) 750-2477
California Fresno ........................ (209) 226-8454 Los Angeles ............... (31 0) 699-7008 Riverside ......... (909) 784-3661 Sacramento ............... (91 6) 369-2495 San Diego ................... (619) 569-8953 San Francisco ............ (510) 462-0986 Ventura ....................... (805) 658-2566
Colorado Colorado Springs ......... (719) 488-81 22 Denver ........................ (303) 799-9003 Denver ......................... (303) 756-5700
Connecticut Hartford ...................... (860) 529-7472
District of Columbia Govt . Servs ................ (301) 921 -2064 Washington ................ (301) 921 -0083
Florida Ft . Myers .................... (81 3) 936-5573 Jacksonville~ .............. (904) 348-31 50 Miami ......................... (305) 698-9400 Orlando ...................... (407) 774-51 51 tall ah as see^ ............... (904) 348-31 50 Tampa ......................... (81 3) 286-0227 A Jacksonville handles phones for Tallahassee
Georgia Albany .......................... (91 2) 889-8464 Atlanta ........................ (404) 333-3660 Augusta ........................ (706) 724-7441 Macon ........................ (91 2) 471 -9033 Muscogee .................. (706) 596-0070 Norcross ...................... (404) 449-9783 Savannah ................... (91 2) 356-9546
Hawaii Honolulu ..................... (808) 522-051 1
ldaho Boise ......................... (208) 376-0552 Idaho Falls .................. (208) 522-6274
Illinois Champaign ................ (21 7) 356-021 1 Chicago ...................... (708) 91 6-9550 Peoria ......................... (309) 673-2554 Rockford .................... (81 5) 965-2060 Sangamon .................. (21 7) 546-1477
Indiana Evansville ................... (81 2) 473-9900 Fort Wayne ................. (219) 483-3194 Hammond .................. (219) 972-9600 Indianapolis ................ (31 7) 475-4141 South Bend ................ (219) 259-8521
lowa Cedar Rapids ............. (319) 366-0736 Davenport A ................. (319) 366-0736 Des Moines A .............. (319) 366-0736 A Cedar Rap~ds answers all lowa off~ces
Kansas Kansas City ................ (91 3) 599-3000 Wichita ....................... (31 6) 264-9338
Kentucky Lexington ................... (606) 278-0308 Louisville .................... (502) 425-8363 Paducah ..................... (502) 554-5515
Louisiana Baton Rouge .............. (504) 924-9923 Monroe ....................... (31 8) 325-4501 New Orleans .............. (504) 837-9022 Shreveport .................. (31 8) 865-4267
Maryland Baltimore .................... (410) 337-8448 Easton ........................ (41 0) 819-0001 Hagerstown ................ (301) 739-5760
Massachusetts Boston ........................ (61 7) 848-1 1 10
Michigan Detroit ......................... (81 0) 680-4444 Flint ............................. (810) 230-6622 Grand Rapids ............. (616) 954-2700 Kalamazoo ................. (61 6) 372-21 17 Lansing ....................... (517) 337-2835 Traverse City .............. (61 6) 946-3773
Minnesota Duluth ........................ (218) 729-4981 Minneapolis ................ (612) 476-6909
Mississippi Hattiesburg ................ (601) 543-01 70 Jackson ...................... (601) 982-1 031 Tupelo ......................... (601) 842-3398
Missouri Jefferson City ............. (314) 893-4426 Springfield .................. (417) 887-2307 St . Louis ..................... (314) 821-8181
Montana Billings ........................ (406) 252-5587
Nebraska Omaha ....................... (402) 330-3753
Nevada Las Vegas ................... (702) 258-8889
New Hampshire Portsmouth ................ (603) 431-1 71 8
New Jersey New Jersey ................ (201) 575-7000
New Mexico Albuquerque ............... (505) 888-8816
New York Albany ....................... (51 8) 452-2590 Binghamton ............... (607) 723-7337 Buffalo ........................ (71 6) 565-1 000 Nanuet ........................ (914) 627-0056 New York .................... (516) 248-0080 Rochester ................... (71 6) 424-41 71 Syracuse .................... (31 5) 457-5593
North Carolina Asheville ..................... (704) 254-5987 Charlotte .................... (704) 529-1 533 E . Carolina .................. (919) 756-21 17 Greensboro ................ (91 0) 292-8995 Raleigh ....................... (919) 782-1 338 Wilmington ................. (91 0) 256-9956
North Dakota Fargo ......................... (701) 235-7223
Ohio Cincinnati ................... (513) 793-681 1 Cleveland ................... (21 6) 526-9070 Columbus ................... (614) 486-4329 Dayton ....................... (513) 297-7771 Toledo ......................... (419) 535-1293
Oklahoma Oklahoma City ........... (405) 942-7334 Tulsa ................... ........ (918) 622-2800
Oregon Portland ...................... (503) 684-1 090
Pennsylvania Allentown ................... (61 0) 694-9600 Altoona ....................... (814) 942-1966 Philadelphia ................ (610) 565-8750 Pittsburgh ................... (412) 921 -381 0 Wilkes-Barre ............... (71 7) 288-1461
York ............................
Puerto Rico San Juan .................... Rhode Island Providence ................. South Carolina Charleston .................. Columbia .................... Florence ...................... Greenville ...................
South Dakota Sioux Falls .................. Tennessee Chattanooga .............. Kingsport .................... Knoxville ..................... Memphis .................... Nashville .....................
Texas Amarillo ...................... Austin ......................... Beaumont .................. Bryan .......................... Corpus Christi ............ DallasIFt . Worth ......... El Paso ....................... Harlingen .................... Houston ..................... Longview .................... Lubbock ..................... Midland ...................... San Antonio ............... Sherman ..................... Wac0 .......................... Wichita Falls ............... Utah Salt Lake City .............
Virginia Charlottesville ............ Norfolk ........................ Richmond ................... Roanoke ..................... Washington Seattle ....................... Spokane .....................
West Virginia West Virginia ............... Wisconsin Green Bay .................. Madison ..................... Milwaukee ..................
international sales offices Stamford. CT ...................................... 353-9372 Los Angeles. CA ............................................................................. (31 0) 699-7008 Miami. FL ............................................................................................. (305) 591 -971 6 Houston. TX 713) 465-5580 Smyrna. TN ....................................... -1 5) 459-5026 Florence, KY ........................................................................................ (606) 525-3888 Milwaukee, WI ...................................... 963-7447
sales offices in Canada Burl~ngton ....................................................................................... (905) 681 -1 178 Calgary ............................................................................................. (403) 243-8890 Dartmouth ....................................................................................... (902) 468-5338 Edmonton ......................................................................................... (403) 453-3561 London ......................................................................................... (519) 438-21 18 Mississauga ................................................................................. (905) 878-7000 Moncton .................................................................................. (506) 857-0719 Montreal .......................... .. ............................................................ (514) 697-4790 North Bay ............................................................................................ (705) 476-1466 Ottawa ............................................................................................... (61 3) 247-71 71 Owen Sound ..................................................................................... (519) 371-0964 Quebec .......................... .. ............................................................. (41 8) 877-9544 R~chmond .......................................................................................... (604) 273-371 1 Saskatoon ..................... ... ........................................................... (306) 242-4046 Sherbrooke ....................................................................................... (819) 822-3676 St . John's ........................................................................................ (709) 739-6374 Sudbury ......................................................................................... (705) 560-9516
Toronto . head office ......................................................................... (41 6) 752-8020 Thunder Bay ........................................................................................ (807) 622-7792 Waterloo ........................................................................................ (519) 886-5270 Windsor ........................................................................................... (519) 974-0900 Winnipeg ........................................................................................ (204) 488-2305
sales offices in Mexico Aguascalientes ............................................................................... 52-49-1 6-00-85 Cancun ................................................................................................. 52-98-875958 CD . Juarez ....................................................................................... 52-16-1 1-0032 Coatzacoalcos .................................................................................. 52-921 -204-64 Chihuahua .......................... .. .......................................................... 52-14-26-5076 Culiacan .................................... ... .............................................. 52-67-12-12-1 1 Focus Facility .................................................................................... 528361 -3776 Guadalajara ...................................................................................... 52-3-647-09-95 Hermosillo ................... ....... ........................................................ 52-62-12-45-55 Leon ................................................................................................. 52-47-73-34-60 Lerma ................................................................................................. .52-72 8-52249 Merida ........................................................................................... 52-99-26-50-92 Monterrey ......................................................................................... 52-8-372-95-25 Nuevo Laredo .................................................................................... 52-871 -300-1 0 Queretaro ........................................................................................ 52-42-1 5-1 0-72 Tampico .......................................................................................... 52-12-28-42-55 Tijuana ............................................................................................ 52-66-81 -27-87 Tlaxcala ........................................................................................ 52-249-797-00 Torreon ............................................................................................. 52-17-20-38-68 Veracruz ......................................................................................... 52-29-31-56-77
Order No . 0600PL9601 Nov 96 Printed in U.S.A. 5M (Replaces 0629PL9501. 0631 PL9501. 0631 PL9502) O 1996 Square D All Rights Resented