Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018 Uncontrolled if printed. Controlled by MTM Process and Interface Engineering. [email protected] Number Certificate Issue Title/Product Function/Application(s) Applicable System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No. Software Version No. Manufacturer's Details Place of Manufacture Condition and Service Restrictions CML086 1 Next Generation CBI- SmartLock 400 Computer Based Interlocking system. Type Approval Superseded 14/05/2010 Next Generation CBI- SmartLock 400 Alstom Transport/Alstom Signalling Solutions As specified on the TA Certificate 01-1201-0001_P_TA 1 Track Circuit ET200 Railway Signalling Equipment - For Train Detection Type Approval Approved EBI Track 200 (TI21) Audio Frequency Track Circuit Bombardier Transportation; UK Ltd United Kingdom Not specified as at this time 01-1201-0003_P_TA 2 Computer Base Interlocking Westrace MK II Computer Based Interlocking system. Type Approval Approved 31/05/2016 Westrace MK II Siemens United Kingdom Nil 01-1201-0004_P_TA 1 AZ S 350U Axle Counter Track Vacany Detection Type Approval Approved 5/04/2012 AZ S 350U Axle Counter Siemens Germany Germany As specified on the TA Certificate 01-1201-0005_P_TA 1 Continuous Earth Leakage Detector To detect earth leakage to any conductor directly connected a power distribution system Type Approval Approved 10/02/2012 MRD-ELD-AC/DC-AUTO-110 Earth Leakage Detector Auto Monotoring Busbar 0-650V AC or 12V-150VDC fault Contact, Item No. ELD AC/DC- AUTO 110 MRD Rail Technologies Pty; Cleveland, Queensland 4163, Australia 235 South Street, Cleveland, Queensland 4163, Australia As specified on the TA Certificate 01-1201-0006_P_TA 1 Tilting Mast Specially designed mast which allows maintenance work to be carried out on the mast at ground level eliminating the risks of working at heights and in close proximity to overhead high voltage power lines Type Approval Approved 20/02/2012 Rail Industry Constructions Pty Ltd., Mayfiedl West, NSW, Australia Unit 15, 5-7 Channel Road, Steel Industrial Estate, Rail Industry Constructions Pty Ltd., Mayfiedl West, NSW, Australia As specified on the TA Certificate 01-1201-0007_P_TA 1 Siemens S 700 V(A) In Bearer Points Points/Turnout Operation Type Approval Approved S 700 V(A) Siemens Australia Germany As specified on the TA Certificate 01-1201-0008_P_TA 1 RailAsset Monitor Signal Equipment Monitoring Type Approval Approved N/A Siemens Australia Germany 01-1201-0009_P_TA 1 SpheroLock Point Locking Mechanism Rail Head point locking mechanism Type Approval Approved VAE Systems Australia As specified on the TA Certificate 01-1201-0010_P_TA 2 UniStar In Bearer points Points/Turnout Operation utilising machine locking Type Approval Superseded CONTEC Gmbh Austria As specified on the TA Certificate 00010 4 UniStar In Bearer points Points/Turnout Operation utilising machine locking Type Approval Approved 20/11/2015 Refer to TA Certificate CONTEC Gmbh Austria As specified on the TA Certificate 01-1201-0011_P_TA 1 EcoStar In Bearer points Points/Turnout Operation utilising Rail Head locking Type Approval Approved VAE Systems Austria As specified on the TA Certificate 01-1201-0012_P_TA 1 ACM 100 Axle Counter Track Vacany Detection Type Approval Withdrawn ACM 100 Siemens Germany Germany As specified on the TA Certificate 01-1201-0013_P_TA 1 Front End Processor (FEP) Signals Type Approval Withdrawn Alstom 01-1202-0014_F_TA 1 Train Protection Warning System Type Approval Approved 2/03/2012 Thales TPWS Refer to certificate 00015 1 Hascom Serial IO MkII PRIDE telemetry (Railmasters) track indications (train movement) back to PRIDE Engineering Product Approval Approved P/N 025001 HASCOM International Pty Ltd 00017 1 Edilon Sedra Embedded Rail System (ERS) Level crossing renewals Type Approval Approved 7/08/2015 30/06/2016 Edilon LC-H / LC-L Edilon Sedra Australia Not specified as at this time 00018 3 Alpha CFRTU 6103 (96 Volts) Alpha CFRTU 6103/SR (48 Volts) Uninterruptible Power Supply Type Approval Approved 1/05/2014 Alpha CFRTU 6103/96 Volts; UPS Alpha Power Systems, Australia 2F Xinye Building, Pioneering Park, Torch Hi- Tech Industrial Development Zone, Xiamen, China 361009 As specified on the TA Certificate 00021 2 VRM Plastic Ground Level Trough (GLT) Plastic GLT can be used as an alternative to traditional concrete or metal GLT to route signalling, communication and power cables. Moulded barriers within the trough allow separation of services and types of cables such as communication and HV cables. Type Approval Approved 8/10/2015 Cable Tray (GLT)/UG2072 Cable Tray Lid (GLT lid) /UG2071 Viscount Rotational Moulding Pty. Ltd. 81 Frankston Gardens Drive, Carrum Downs, Vic 3201 As specified on the TA Certificate 00022 1 Railway Type 1 Pit & Lid / UG2078 Plastic pits can be used as an alternative to traditional concrete pits, for access to cable routes for signalling, communication and power cables. Plastic pits can also be used as turning chambers where cable routes require a change of direction (of more than 45 degrees). Type Approval Approved 5/03/2013 Railway Type 1 Pit & Lid / UG2078 Viscount Rotational Moulding Pty. Ltd. 81 Frankston Gardens Drive, Carrum Downs, Vic 3201 As specified on the TA Certificate 00024 1 Westlock CBI S1.05 Computer Based Interlocking system. Type Approval Approved 26/02/2013 WESTLOCK/S1.05 Invensys Rail UK United Kingdom Nil 00025 2 2000R/AF Impedance Bond Track Circuits/ Traction application for 50Hz/AC or Audio Frequency Track Circuits (CSEE) Type Approval Approved 3/02/2014 SDM 2000 Sulzer Dowding and Mills Laverton, Victoria, Australia Not specified as at this time 00026 5 UniPart Rail Hollow Sleeper Assembly Railway signal or communication cables containment where local cables are required to be placed under tracks Type Approval Approved 25/06/2016 Hollow Sleeper 1600 (full depth) and 1700 (shallow depth) series Trackwork Limited/Unipart Rail Australasia Hetton Lyons Industrial Estate; Tyne & Wear; DH5 0RF ; United Kingdom As specified on the TA Certificate 00027 2 PZH AS60kg Standard Carbon New Work, Maintenance and Renewal of Track. Type Approval Suspended (Until Further Notice) 27/08/2013 AS60kg Standard Carbon Panzhihua Steel and Vanadium Co. Ltd. Panzhihua, China Type Approval suspended until further notice 00028 1 Low Profile Concrete Sleepers Re-sleepering, track construction Type Approval Approved 24/04/2014 SRM-LPCS-001 LECHANGSHI ANJIE RAILWAY SLEEPER CO China Only to be used with SINO Rail Fastening 00029 1 100 Series Fastening Used in combination with LPCS for resleepering, track construction Type Approval Approved 24/04/2014 Clip Housing - SRM-100-SHD-001 Clip - SRM-100-CLP-001 Pad - SRM -100-PAD-001 Insulator - SRM -100-INS-001 ANYANG RAILWAY PRODUCT CO China Only to be used with SINO Sleepers 00030 1 Unipart Dorman LED Possession Limit Board Board/sign (i.e. visible marker) installed on the rail head to mark the limit of an Absolute Occupation with a large, reflective STOP sign and a flashing red LED light. Type Approval Approved PLB6N/RR/01/001 Unipart Dorman Nil 00031 1 Heinemann F35D160Y 110V Signalling Power Isolation; SUN534SEH Engineering Product Approval Withdrawn F35D160Y Heinemann ??? Not specified as at this time 00032 1 Heinemann F35D200Y 110V Signalling Power Isolation; SUN534SEH Engineering Product Approval Withdrawn F35D200Y Heinemann ??? Not specified as at this time 00033 3 Electromagnetic Latched Pedestrian Escape Exit Gate Pedestrian Crossings Type Approval Approved Issue 1 - DMS Standard drawing STD_C0020 Nov 2013 Issue 2 - DMS Standard drawing STD_C0035 May 2016 Issue 3 - DMS Standard drawing STD_G0305 July 2017 DMS Standard drawing STD_G0305 Australia Trial Installation at Lilydale up end platform station access for a 6 month operations of Electromagnetic Escape Exit Gate Arrangement. Improved gate post design and 1600mm high gate and push button panel adopted for the network. 00034 1 161mm2 Contact Wire Overhead traction supply to the 1500 V dc metropolitan railway system Type Approval Approved 28/08/2013 3104004846 Lamifil, Belgium Frederic Sheidlaan, B-2620 Hemiksen, Belgium Trial Installation of Contact Wire 00035 1 Intelepower CXS48V, 120A Battery Charger Battery charger for 48V dc control system Type Approval Approved 23/05/2013 331019 Century Yuasa Batteries Pty Ltd. 42-46 Dunlop Rd, Mulgrave, VIC 3170 As specified on the TA Certificate 00036 3 Elsafe Surge Protection Unit(SPU) Signalling Type Approval Approved 21/11/2014 555665 and 216600A; 216660, 555220, 216690, 555710, 216600A, 555175 Elsafe, Australia Australia As specified on the TA Certificate 00037 4 Mechanical Blade Anchor Lock Locking mechanism for staging works as part of turnout Installation Type Approval Approved 3/02/2014 Mechanical Blade Anchor Lock for Asymmetric Switches, AS60kg (Drawing A0B17211, Rev A) Mechanical Blade Anchor Locks For Single & Double Compounds, AS60kg (Drawing A1B17724, Rev A) Mechanical Blade Anchor Locks For Dg Type 40 Turnout, AS50kg (Drawing A1B17730, Rev A) Vossloh Cogifer Castlemaine, Victoria, Australia Trial installation of Mechanical Blade Anchor Lock at South Kensington. 00038 1 Eaton Magnefix MD4 Plus Switchgear Electrical supply to signalling and protection equipment along railway tracks. Type Approval Withdrawn 3/06/2013 Eaton Holec Magnefix MD4 Plus Switchgear Eaton Electric B.V. Hengelo, The Netherlands As specified on the TA Certificate 00039 1 Eaton Magnefix MD4 Switchgear Electrical supply to signalling and protection equipment along railway tracks. Type Approval Withdrawn 3/06/2013 Eaton Holec Magnefix MD4 Switchgear Eaton Electric B.V. Hengelo, The Netherlands As specified on the TA Certificate 00040 3 SIGWAY FEP Signalling Protocol Convertor Type Approval Approved 28/11/2014 Model: UNO-3084-D23E Hardware Configuration Item (CI): 1.0.1 Computer Software Configuration Item (CSCI): Server 1.0.21 Patch 23.14 Alstom Ltd Australia As specified on the TA Certificate 00041 1 AzLS - single line Axle Counter Type Approval Withdrawn Hardware Configuration Item (CI): 1.0.1 Thales 00042 2 AzLM - multi line Axle Counter Type Approval Approved 24/05/2016 FieldTrac 6315 AzLM Microprocessor-Based Multiple Section Axle Counter v6.4 Thales Refer to certificate 00043 1 DVTel Mini Dome Camera Engineering Product Approval Approved CM-2101-21P 00044 1 Rebosio Insulated Arm Bridges and other areas with restricted overhead clearance. Type Approval Approved 15/07/2013 SC 10181, M01347 and LT1659 Bonomi Eugenio - Rebosio Italy As specified on the TA Certificate 00046 1 Friction Buffer Stop Buffer Stop For terminal Point Protection Track & Structures Type Approval Approved 31/07/2013 10EB, 10EB M+S, 12 ZEB/5, 16ZEB A.RAWIE GmbH & Co. Germany As specified on the TA Certificate 00048 1 Grease Applicators Rail Lubrication Type Approval Withdrawn Various LB Foster 00050 1 Vi24xx series Ethernet extenders over coax Analogue to Digital CCTV Engineering Product Approval Approved Vi2401, single port; Vi2404, four port; Vi2408, eight port; Vi2416, sixteen port. Vigitron USA 00051 1 Vigitron MaxiiCopper Vi22xx series High- Power POE Midspan: Ethernet switch with high power PoE demand. Engineering Product Approval Approved Vi2208 Vi2216 Vigitron USA

Upload: ngokien

Post on 06-Mar-2018

907 views

Category:

Documents


42 download

TRANSCRIPT

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

CML086 1 Next Generation CBI- SmartLock 400 Computer Based Interlocking system. Type Approval Superseded 14/05/2010 Next Generation CBI- SmartLock 400 Alstom Transport/Alstom Signalling Solutions As specified on the TA Certificate

01-1201-0001_P_TA 1 Track Circuit ET200 Railway Signalling Equipment - For Train Detection Type Approval Approved EBI Track 200 (TI21) Audio Frequency Track Circuit

Bombardier Transportation; UK Ltd

United Kingdom Not specified as at this time

01-1201-0003_P_TA 2 Computer Base Interlocking Westrace MK II Computer Based Interlocking system. Type Approval Approved 31/05/2016 Westrace MK II Siemens United

Kingdom Nil

01-1201-0004_P_TA 1 AZ S 350U Axle Counter Track Vacany Detection Type Approval Approved 5/04/2012 AZ S 350U Axle Counter Siemens Germany Germany As specified on the TA Certificate

01-1201-0005_P_TA 1 Continuous Earth Leakage Detector To detect earth leakage to any conductor directly connected a power distribution system Type Approval Approved 10/02/2012

MRD-ELD-AC/DC-AUTO-110 Earth Leakage Detector Auto Monotoring Busbar 0-650V AC or

12V-150VDC fault Contact, Item No. ELD AC/DC-AUTO 110

MRD Rail Technologies Pty; Cleveland, Queensland 4163,

Australia

235 South Street,

Cleveland, Queensland

4163, Australia

As specified on the TA Certificate

01-1201-0006_P_TA 1 Tilting MastSpecially designed mast which allows maintenance work to be carried out on the mast at ground level eliminating the risks of working at heights and in close proximity to overhead high voltage power lines

Type Approval Approved 20/02/2012Rail Industry Constructions Pty

Ltd., Mayfiedl West, NSW, Australia

Unit 15, 5-7 Channel

Road, Steel Industrial

Estate, Rail Industry

Constructions Pty Ltd., Mayfiedl

West, NSW, Australia

As specified on the TA Certificate

01-1201-0007_P_TA 1 Siemens S 700 V(A) In Bearer Points Points/Turnout Operation Type Approval Approved S 700 V(A) Siemens Australia Germany As specified on the TA Certificate01-1201-0008_P_TA 1 RailAsset Monitor Signal Equipment Monitoring Type Approval Approved N/A Siemens Australia Germany

01-1201-0009_P_TA 1 SpheroLock Point Locking Mechanism Rail Head point locking mechanism Type Approval Approved VAE Systems Australia As specified on the TA Certificate

01-1201-0010_P_TA 2 UniStar In Bearer points Points/Turnout Operation utilising machine locking Type Approval Superseded CONTEC Gmbh Austria As specified on the TA Certificate00010 4 UniStar In Bearer points Points/Turnout Operation utilising machine locking Type Approval Approved 20/11/2015 Refer to TA Certificate CONTEC Gmbh Austria As specified on the TA Certificate

01-1201-0011_P_TA 1 EcoStar In Bearer points Points/Turnout Operation utilising Rail Head locking Type Approval Approved VAE Systems Austria As specified on the TA Certificate01-1201-0012_P_TA 1 ACM 100 Axle Counter Track Vacany Detection Type Approval Withdrawn ACM 100 Siemens Germany Germany As specified on the TA Certificate01-1201-0013_P_TA 1 Front End Processor (FEP) Signals Type Approval Withdrawn Alstom01-1202-0014_F_TA 1 Train Protection Warning System Type Approval Approved 2/03/2012 Thales TPWS Refer to certificate

00015 1 Hascom Serial IO MkII PRIDE telemetry (Railmasters) track indications (train movement) back to PRIDE Engineering Product Approval Approved P/N 025001 HASCOM International Pty Ltd

00017 1 Edilon Sedra Embedded Rail System (ERS) Level crossing renewals Type Approval Approved 7/08/2015 30/06/2016 Edilon LC-H / LC-L Edilon Sedra Australia Not specified as at this time

00018 3 Alpha CFRTU 6103 (96 Volts) Alpha CFRTU 6103/SR (48 Volts) Uninterruptible Power Supply Type Approval Approved 1/05/2014 Alpha CFRTU 6103/96 Volts; UPS Alpha Power Systems,

Australia

2F Xinye Building,

Pioneering Park, Torch Hi-

Tech Industrial

Development Zone,

Xiamen, China

361009

As specified on the TA Certificate

00021 2 VRM Plastic Ground Level Trough (GLT)

Plastic GLT can be used as an alternative to traditional concrete or metal GLT to route signalling, communication and power cables. Moulded barriers within the trough allow separation of services and types of cables such as communication and HV cables.

Type Approval Approved 8/10/2015 Cable Tray (GLT)/UG2072Cable Tray Lid (GLT lid) /UG2071

Viscount Rotational Moulding Pty. Ltd.

81 Frankston Gardens

Drive, Carrum Downs, Vic

3201

As specified on the TA Certificate

00022 1 Railway Type 1 Pit & Lid / UG2078

Plastic pits can be used as an alternative to traditional concrete pits, for access to cable routes for signalling, communication and power cables. Plastic pits can also be used as turning chambers where cable routes require a change of direction (of more than 45 degrees).

Type Approval Approved 5/03/2013 Railway Type 1 Pit & Lid / UG2078 Viscount Rotational Moulding Pty. Ltd.

81 Frankston Gardens

Drive, Carrum Downs, Vic

3201

As specified on the TA Certificate

00024 1 Westlock CBI S1.05 Computer Based Interlocking system. Type Approval Approved 26/02/2013 WESTLOCK/S1.05 Invensys Rail UK United Kingdom Nil

00025 2 2000R/AF Impedance Bond Track Circuits/ Traction application for 50Hz/AC or Audio Frequency Track Circuits (CSEE) Type Approval Approved 3/02/2014 SDM 2000 Sulzer Dowding and Mills

Laverton, Victoria, Australia

Not specified as at this time

00026 5 UniPart Rail Hollow Sleeper Assembly Railway signal or communication cables containment where local cables are required to be placed under tracks Type Approval Approved 25/06/2016 Hollow Sleeper 1600 (full depth) and 1700 (shallow

depth) seriesTrackwork Limited/Unipart Rail

Australasia

Hetton Lyons Industrial

Estate; Tyne & Wear; DH5 0RF ; United

Kingdom

As specified on the TA Certificate

00027 2 PZH AS60kg Standard Carbon New Work, Maintenance and Renewal of Track. Type Approval Suspended (Until Further Notice) 27/08/2013 AS60kg Standard Carbon Panzhihua Steel and Vanadium

Co. Ltd.Panzhihua,

China Type Approval suspended until further notice

00028 1 Low Profile Concrete Sleepers Re-sleepering, track construction Type Approval Approved 24/04/2014 SRM-LPCS-001 LECHANGSHI ANJIE RAILWAY SLEEPER CO China Only to be used with SINO Rail Fastening

00029 1 100 Series Fastening Used in combination with LPCS for resleepering, track construction Type Approval Approved 24/04/2014

Clip Housing - SRM-100-SHD-001Clip - SRM-100-CLP-001Pad - SRM -100-PAD-001

Insulator - SRM -100-INS-001

ANYANG RAILWAY PRODUCT CO China Only to be used with SINO Sleepers

00030 1 Unipart Dorman LED Possession Limit Board

Board/sign (i.e. visible marker) installed on the rail head to mark the limit of an Absolute Occupation with a large, reflective STOP sign and a flashing red LED light. Type Approval Approved PLB6N/RR/01/001 Unipart Dorman Nil

00031 1 Heinemann F35D160Y 110V Signalling Power Isolation; SUN534SEH Engineering Product Approval Withdrawn F35D160Y Heinemann ??? Not specified as at this time

00032 1 Heinemann F35D200Y 110V Signalling Power Isolation; SUN534SEH Engineering Product Approval Withdrawn F35D200Y Heinemann ??? Not specified as at this time

00033 3 Electromagnetic Latched Pedestrian Escape Exit Gate Pedestrian Crossings Type Approval Approved

Issue 1 - DMS Standard drawing STD_C0020 Nov 2013

Issue 2 - DMS Standard drawing STD_C0035 May 2016

Issue 3 - DMS Standard drawing STD_G0305 July 2017

DMS Standard drawing STD_G0305 Australia

Trial Installation at Lilydale up end platform station access for a 6 month operations of Electromagnetic Escape Exit Gate Arrangement.Improved gate post design and 1600mm high gate and push button panel adopted for the network.

00034 1 161mm2 Contact Wire Overhead traction supply to the 1500 V dc metropolitan railway system Type Approval Approved 28/08/2013 3104004846 Lamifil, Belgium

Frederic Sheidlaan,

B-2620 Hemiksen,

Belgium

Trial Installation of Contact Wire

00035 1 Intelepower CXS48V, 120A Battery Charger Battery charger for 48V dc control system Type Approval Approved 23/05/2013 331019 Century Yuasa Batteries Pty

Ltd.

42-46 Dunlop Rd, Mulgrave,

VIC 3170As specified on the TA Certificate

00036 3 Elsafe Surge Protection Unit(SPU) Signalling Type Approval Approved 21/11/2014555665 and 216600A;

216660, 555220, 216690, 555710, 216600A, 555175

Elsafe, Australia Australia As specified on the TA Certificate

00037 4 Mechanical Blade Anchor Lock Locking mechanism for staging works as part of turnout Installation Type Approval Approved 3/02/2014

Mechanical Blade Anchor Lock for Asymmetric Switches, AS60kg (Drawing A0B17211, Rev A)Mechanical Blade Anchor Locks For Single &

Double Compounds, AS60kg (Drawing A1B17724, Rev A)

Mechanical Blade Anchor Locks For Dg Type 40 Turnout, AS50kg (Drawing A1B17730, Rev A)

Vossloh CogiferCastlemaine,

Victoria, Australia

Trial installation of Mechanical Blade Anchor Lock at South Kensington.

00038 1 Eaton Magnefix MD4 Plus Switchgear Electrical supply to signalling and protection equipment along railway tracks. Type Approval Withdrawn 3/06/2013 Eaton Holec Magnefix MD4 Plus Switchgear Eaton Electric B.V. Hengelo, The Netherlands As specified on the TA Certificate

00039 1 Eaton Magnefix MD4 Switchgear Electrical supply to signalling and protection equipment along railway tracks. Type Approval Withdrawn 3/06/2013 Eaton Holec Magnefix MD4 Switchgear Eaton Electric B.V. Hengelo, The Netherlands As specified on the TA Certificate

00040 3 SIGWAY FEP Signalling Protocol Convertor Type Approval Approved 28/11/2014 Model: UNO-3084-D23EHardware

Configuration Item (CI): 1.0.1

Computer Software

Configuration Item (CSCI): Server 1.0.21 Patch 23.14

Alstom Ltd Australia As specified on the TA Certificate

00041 1 AzLS - single line Axle Counter Type Approval Withdrawn Hardware Configuration Item (CI): 1.0.1 Thales

00042 2 AzLM - multi line Axle Counter Type Approval Approved 24/05/2016FieldTrac 6315 AzLM

Microprocessor-Based Multiple Section Axle Counter v6.4

Thales Refer to certificate

00043 1 DVTel Mini Dome Camera Engineering Product Approval Approved CM-2101-21P

00044 1 Rebosio Insulated Arm Bridges and other areas with restricted overhead clearance. Type Approval Approved 15/07/2013 SC 10181, M01347 and LT1659 Bonomi Eugenio - Rebosio Italy As specified on the TA Certificate00046 1 Friction Buffer Stop Buffer Stop For terminal Point Protection Track & Structures Type Approval Approved 31/07/2013 10EB, 10EB M+S, 12 ZEB/5, 16ZEB A.RAWIE GmbH & Co. Germany As specified on the TA Certificate00048 1 Grease Applicators Rail Lubrication Type Approval Withdrawn Various LB Foster

00050 1 Vi24xx series Ethernet extenders over coax Analogue to Digital CCTV Engineering

Product Approval Approved

Vi2401, single port;Vi2404, four port;Vi2408, eight port;

Vi2416, sixteen port.Vigitron USA

00051 1 Vigitron MaxiiCopper Vi22xx series High-Power POE Midspan: Ethernet switch with high power PoE demand. Engineering

Product Approval Approved Vi2208 Vi2216 Vigitron USA

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

00052 2 Marciano Double Skin Location CasesUsed for boxes that is prone to high internal heat increases. (i.e. areas with no adequate shading or boxes that require a large amount of electronic components),13/02/2018 version 2 has captured the addition sized equipment case and its preferred foundation

Signals Type Approval Approved 1/04/2014

version 1 approved 01/04/2014 MRSC-SC01 - Complete Single Width Case

MRSC-DC01 - Complete Double Width CaseMRSCR-SC01 - Signal Width Case Re-Skinning

KitMRSCR-DC01 - Double Width Case Re-Skinning

Kitversion 2 approved xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx

13/02/2018 version 2 has captured the addition sized equipment case and its preferred foundation

na na Marciano Industries

12 Century Circuit,

Baulkham Hills, NSW,

Australia

None

00053 1 Platform Gap Filler Platform Gap Filler for access to Metro Trains Type Approval Approved 9/12/2013 Various TMT Co. Ltd. China None

00054 1Switch Mode Power Supply (48Vdc,

110Vdc, 24Vdc)Smartpack Controller and Flatpack

Type Approval Withdrawn

241115.205 Flatpack2 Rectifier 24V, 1800W HE

241115.805 Flatpack2 Rectifier 110VDC, 2000W HE

Eltek Valere

00056 2 GE Tempo Interlocking Urban and mainline applications, configured either as a centralised or distributed CBI/object controller architecture. Type Approval Approved

Tempo IXL Baseline 2 hardware modules and software. Modules included: VCPU, CPU4, VFCI,

DOLP, DOULP, Bridge, DGN, Core rack, peripherals rack, PSU.

GE Transportation Europe France and Italy

1. The Tempo IXL shall only be installed at the Carrum location for site trial purposes.2. Power inputs to the Tempo IXL shall be connected such that they will not impact on the upstream power supply.3. Signalling inputs to the Tempo IXL shall be connected such that they are non-intrusive to the connected in-service equipment, and can be readily disconnected in the case of a fault.

00063 1 Schneider PREMSET 15 kV Electrical 2.2kV Supply Type Approval Withdrawn 14/11/2013 31/10/2014 D02N , I06T with G06 Schneider France One Installation only at North Melboure Substation - 6 month trial May - Dec 201400065 2 Gayrad 50V Regulated Power Supply 110V AC - 50V DC Power Supply Type Approval Approved 14/12/2017 na WQRTJF50/5-R Gayrad Australia Provisional for Westrace MkII installation at Mitcham Rooks Road, and made final on 14/12/2017 , with NO conditions attached to its use

00067 1 Vossloh Multi Purpose Point Clip Securing of Points Type Approval Approved 26/08/2015 416.B17266V01416.B17266V04 Vossloh Cofiger Australia Australia Nil

00068 5 Railduct High Density Polyethylene (HDPE) moulded cable trough system. Track & Structures Type Approval Approved 5/04/2016

610003 - Railduct™ cable trough complete610001 - Railduct™ cable trough body only610002 - Railduct™ cable trough cover only

610005 - Railduct™ cable trough divider610004 - Railduct™ cable trough T Piece

Cubis Systems Northern Ireland Refer to Certificate

00070 1 Pandrol FASTCLIP FE1400 This product is used to fasten rail to concrete sleepers. Type Approval Approved 11/02/2014 FE1400 Pandrol Australia Pty Ltd Australia Nil

00071 1 Milspec Double Skin Location Cases Used for boxes that is prone to high internal heat increases. (i.e. areas with no adequate shading or boxes that require a large amount of electronic components) Type Approval Approved 27/03/2014 M02737 & M03619 Milspec Manufacturing Pty Ltd

161 – 169 Fallon Street, Albury, NSW,

Australia

None

00071a 1 Milspec Double Skin Location Cases Reskinning Type Approval Approved

00072 1 Signal Mast Extendable Stand Off Bracket Mitigation of signal sighting issues based on location of signal mast Type Approval Approved 25/07/2014 DH-2014-005 DH Engineering Pty. Ltd. Victoria

Australia

Future installation to be on case-by-case basis as approved by Head of Engineering Signals & OCS.Design to prevent mast from extending into Kinematic Envelope.Only to be used with single signal head units.

00073 1 Robel Rail Clamps Rail Clamps for Mechanical Jointing of Broken Rails Type Approval Approved 4/03/2014 Rail clamp long 68.05 ROBEL Bahnbaumaschinen GmbH Germany

The maximum train speed over the clamp is 80 kphThe clamp should be checked and retightened after one train and then monitored every 72 hours until removal.To be stored in dry location to minimise corrosion.Do not fit where groundwater is affected by salt water.Not to be used on weld repair plates. Not be used on bow plates

00073A 1 Robel Rail Clamps Rail Clamps for Mechanical Jointing of New Track Construction, Closure Rails in Existing Track and Rerailing. Type Approval Approved 26/08/2015 26/09/2015 Rail clamp long 68.05 ROBEL Bahnbaumaschinen

GmbH Germany

00077 1 53kg Mechanical Insulated Rail Joint Electrical solation of adjacent track sections of jointed rail for the effective operation track circuits Type Approval Approved 53kg Mechanical Insulated Rail Joint Imtram Pty Ltd Australia

Approved for trial on MTM network. Installation locations to be approved by Head of Engineering – Track and Structures.Review of product to be completed at completion of trial period confirming UV compliance, wear resistance and successful installation of these components during the initial trial.

00078 2 ARSC 47kg railGlued joints and fabricated points & V crossingsRail closures for RFD repair in accordance with MTPR 033000-10 – Welded Track Management Manual Chapter 10 – Closure Rails

Type Approval Approved 29/09/2015 47kg N/A China Rail not approved for FBW. Separate application will be required to expand the Type Approval to cover FBW.

00079 2 Hedkote Welding Process Repair of defects in rail and crossings Track & Structures Full Type Approval Approved 21/06/2016 N/A N/A N/A Hardface Technology Australia 6 month trial has expired. Re-submission post provisional type approval to full type approval has been completed and certified. Please refer to the hyperlinked location for description of the restrictions/conditions/limitations.

00080 1 Famco Viking LED Luminaire MURL Emergency Lighting Type Approval Approved FSP 16773 Famco Lighting PtyLtd Australia Approved for trial in the MURL00081 2 Clevertronics LED Luminaire MURL Emergency Lighting Type Approval Approved 17/12/2014 LWP2LIFEM-PRO-WPPOD-400-ZW-4HR Clevertronics Australia Full approval for installatin in MURL

00082 3 Zöllner Automated Track Warning System Automated mobile track protection Type Approval Approved 4/09/2015 Refer to TA Certificate Zöllner Signal GMBH Germany • Not approved for use in MURL.

• To be used in accordance with safe working procedure L1-SWS-PRO-016.

00083 2Dual Inventive ZKL3000 and ZKL3000-

RC Track Circuit Operating Devices (TCOD)

A TCOD for activating track circuits during planned engineering operations in accordance with Operational Requirements. Signals Type Approval Approved 18/12/2015 Refer to TA Certificate Dual Inventive BV Netherlands Refer to certificate

00085 1 DEHN Spark-gap Overvoltage protection of 1500V DC Apparatus Electrical Networks Type Approval Approved 10/02/2016 MA SDS M12 (723 199) and SDS1 (923 110) N/A N/A DEHN & SOHNE GmbH &Co Neumarkt, Germany Nil

00086 2 Siemens Axle Counters Type Approval Approved 20/08/2015 ACM 200 Siemens Refer to certificate

00088 1 Switchguard D150 derail MkII & C150 cwoder MkII Type Approval Approved

00089 1 Siemens’ Wayguard DC Shunting Panel

The Siemens Wayguard DC Shunting Enhancer Panel is suitable for:-• Use with the Siemens Grade Crossing Predictor3000 and 2000• Trial with the Highway Crossing Processor (HXP3) Signals Type Approval Approved 13/04/2015 31/10/2015 8000-80049-0001; 8000-80049-0005 Siemens Rail Automation Germany

1. Projects shall ensure that appropriate protection from lightning and surges is provided in accordance with the VRIOGS and the supplier's recommendations.2. During the test and commissioning of the trail shunt enhancer, a test train shall be used to ensure the shunt enhancer has not degraded the proper operation of the HPX3 system. Further, the test train shall be used to demonstrate the enhanced performance of the shunt enhancer.3. Should the test and commissioning tests inclusive of the use of a test train in accordance with item 2) above be unsuccessful, then the shunt enhancer shall be decommissioned from use immediately.4. The test and commissioning pass/fail criteria shall be included with the relevant test and commissioning documentation5. Approved for 6 month trial at Disney St Level Crossing.6. This Type Approval is for Siemens Wayguard DC Shunting Enhancer Panel. Any subsequent versions will need to be reassessed for further Type Approval prior to use in the Victorian rail network.

00090 1 Soundwed London BLU-100 Signal Processor (Public Address) Public Address system on the concourse at Flinders Street station Engineering

Product Approval Approved 13/03/2015 BLU-100 Soundweb London Nil

00091 1 Crown Power Amplifier CDi Analog 2-1250 (2 channel) Public Address system on the concourse at Flinders Street station Engineering

Product Approval Approved 13/03/2015 CDi 2-1250 Crown by Harman Nil

00094 1 Contec ClipFix System Cable channel installation to the foot of rail. Track & Structures Type Approval Approved 16/10/2015 Refer to TA Certificate Contec Transportation Systems Germany Refer to TA Certificate

00095 2 Lincoln Wayside Rail Lubricator System Rail Lubrication System Track & Structures Full Type Approval Approved 22/12/2017 Wayside Railroad Lubricator: 85666 & 85667Clamp Kit: 276624 & 276625 Lincoln Industrial Corp

1. The lubricator shall be installed in accordance with manufacturer’s installation manual and MTM Rail Lubrication Standard.2. The lubricator shall be installed with an amplifier gain adjustment box, electronic signal conditioning module (for filtering), suppressors and wiring configured to turn off hydraulic track selection valves when the pump is shut down due to a hydraulic failure alarm. 3. The lubricator shall be installed with the Wayside SafeStop module. The module is a fail-safe solution that prevents the pump motor from operating continuously for extended periods of time (i.e. for more than one minute), by removing power from the motor.4. Inspection and Test Plans shall be completed for each lubricator installed to ensure the accuracy of the axle count and lubrication performance meet the design intent. 5. The network and lubricator security shall comply with the Victorian Protective Data Security Standards (VPDSS).6. Applicator bars shall not be installed on rail smaller than AS 50kg.7. Lubricant used to fill Lincoln Lubricator shall be an MTM Type Approved lubricant.

00096 1 Claretech Supreme Rail Lubricant Lubricating Grease Track & Structures Full Type Approval Approved 13/07/2017 0027/030003 R S Clare & Co Ltd UK1. The product is harmful if swallowed, can cause burns and may cause sensitisation by inhalation and skin contact. Use of PPE and safe handling instructions as outlined in the Material Safety Data Sheets must be strictly adhered to.2. Mandatory training of staff in the safe and correct use and handling of the product must be undertaken before practical field application/maintenance.

00104 1 EZSeries 10”TFT Windows HMIHMI Panels are to be used within MTM substations, tie stations and switching stations as part of the current SCADA system to allow operators remote control and monitoring of equipment within the facility

Type Approval Approved 10/02/2016 31/12/2016

EZSeries 10” & 15”TFT Windows HMI• EZ Series Touch Panel Editor (P/N EZ-

ANELEDIT)• CPU Type: Intel Atom E640 1 GHz with 1GB

DDR2 RAM

• EZ Series Touch Panel

Editor (P/N EZ-ANELEDIT)

• CPU Type: Intel Atom E640 1 GHz with 1GB DDR2 RAM

UTICOR USA

1. Only authorised HV Operators with level T1 and T2 certification are to operate the panel.2. Two locations will trial the HMI Panels for a period of 6 months prior to network wide rollout. The trials will be conducted at Burnley Substation and Surrey Hills Tie Station. If trials are deemed successful, network wide rollout will occur.3. A formal engineering review of the trial is to be conducted in accordance with the management of change process.4. Familiarisation of the equipment is to be conducted by the high voltage trainer for the trial.

00105 1 Millennium Call Processing System MURL Station Public Address System OCS Engineering Product Approval Approved 15/12/2015 METRO-MCPS-V1 Dallas Delta Pty Ltd

This approval is to be limited to this specific functionality to allow remote public address announcements to the MURL stations only.Changes to existing public address system operation at all other locations may consider this system for suitability / flexibility and if suitable could be approved by amendment to this TA.

Not to be relied upon as an emergency evacuation device.

00106 1 Next Generation CBI- SmartLock 400 Computer Based Interlocking system. Interlocking Type Approval Approved 3/07/2015 Next Generation CBI- SmartLock 400 1.4.4 1.4.4 Alstom Transport/Alstom Signalling Solutions France Nil

00107 1 Thermoplastic Urethane Escalator Handrail. Escalator hand rail. Track & Structures Type Approval Approved NT3000 N/A N/A EHC Global China

• Approved for 6 month trial at Box Hill to monitor • Installation in accordance with EHC – NT Handrail Replacement – On site Installation to an Existing Machine• Following products should NOT be used for cleaning o Abrasive cleaners o Wax and other lubricants o Ethyl Alcohol.

00108 1 Benkler MK1HT 4 Hole Kit Type Approval Superseded 21/04/2017

BK-47KGMK1HTX4H BK-50KGMK1HTX4HBK-53KGMK1HTX4HBK-60KGMK1HTX4H

N/A N/A Tenconi SA

00109 1 JR12 DCCB Safety Barrier Installation in front of JR12 DCCBs for protection against inadvertent contact by trained substation personnel. Type Approval Approved 12/06/2015 As per drawing STD_E0148 N/A N/A Metro Trains Melbourne Australia

• The materials listed as safety critical in the ‘Material part Numbers’ document affect the safety criticality rating of the barrier and shall not be substituted with any other brands or models.• Drawing STD_E0148 is only suitable for JR12 DCCB equipped Substations/Tiestations with zones equal to or less than 2750mm in width. Substations/Tiestations with zones greater than 2750mm will require a site specific design based on drawing STD_0148 and approved by the MTM Chief Engineer.

00112 1 200mm Glass Disc Insulator For installation on the overhead wiring system Overhead Type Approval Approved 2/12/2015 CE-U70CN N/A N/A Nanjing Electric (Group) Co. Ltd. China Nil

00113 3 RUGGEDCOM RS900G Network switch OCS Type Approval Approved 6/06/2016 RS900G RS900G Siemens Canada OCS Industrial Control & Signalling Networks

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

00114 1 Holdfast / Rosehill Rubber Level Crossing System Level Crossing Construction Track & Structures Type Approval Approved 26/08/2015 30/06/2016 Holdfast / Rosehill Rubber Rail Crossing Panels N/A N/A Rosehill Polymers Limited UK UK

1. Approved for one trial location only.2. Configuration to explicitly recorded in the Full Type Approval.3. Sleepers spacing through level crossing shall be at 600mm as rubber panels are 1.8m in length. This ensures adequate support where panels are joined.4. Line speed less than 200km/hr and less than 25T axle loads5. Panels shall be installed on tangent track OR on curves with radius >400m on approval.6. Road traffic volume shall not exceed 2500 commercial (heavy) vehicles per lane per day.7. Road speed limit shall not exceed 110 km/hr and alignment of road and rail shall be between 60° and 90°. 8. Shall be installed to manufacturer’s instructions9. End Restraints, as per Manufacturer’s design or an approved equivalent, shall be fitted to end panels.

00115 1 STRAIL Rubber Level Crossing System Level Crossing Construction Track & Structures Type Approval Approved 26/08/2015 30/06/2016 STRAIL Rubber Level Crossing System N/A N/A Gummiwerk KRAIBURG Elastik GmbH Germany

1. Approved for one trial location only.2. Configuration to explicitly recorded in the Full Type Approval.3. Shall be installed to manufacturer’s instructions.4. Road speed limit shall not exceed 110 km/hr.5. Sleeper spacing in Level Crossing shall be nominal 600mm.

00116 2 Dwarf Tilting Signal Mast (2.5 Meters) Dwarf Signal Mast Structure (Built In Tilting Functionality) Signals Type Approval Approved 20/11/2015 TILTMAST2500 N/A N/ARail Industry Construction Pty

LtdMayfield West, NSW 2304

Australia

1. Only to be installed with front mounted "U" style LED signal heads with a maximum weight of 50kg (including brackets).2. When working with the tilting mast, hard hat shall always be worn.3. The installation of the tilting mast shall not foul the running lines.4. The installation of the tilting mast shall ensure that when in the lowered position, the mast shall be parallel with the running line and the signal lens shall always face the ground direction.5. A safety lanyard provided as part of the tilting mast shall be used for a secondary protecting mechanism.6. The mast shall be lowered and raised in compliance with L3-SIG-MAl-004 / MSMP 030100-04 "Signal Maintenance Instruction Railway Industry Constructions (RIC) Tilting Signal Mast" Version 1 dated 16/03/2012.7. The mast shall be maintained in compliance with the operational requirements shown in L3-SIG-PRO-001 / MSMP 030100-04 "Signal Maintenance Procedure Signalling & Safeworking for Maintenance of Tilting Signal Mast" Version 1 dated 16/03/2012.

00117 1 Digital Ambient Noise Controller The Digital Ambient Noise Controller and Ambient Noise Sensing Microphone will be components of the OCS / Passenger Information System / Public Address System. OCS Engineering

Product Approval Approved 22/12/2015 DP-L2 TOA Corporation N/A Forms part of the OCS Public Address System, to improve customer audio clarity while minimising unnecessary loudness for nearby residences, and is to be used with exclusively with the AN-9001 Ambient Noise Sensing Microphone (TA 00118).

00118 1 Ambient Noise Sensing Microphone The Digital Ambient Noise Controller and Ambient Noise Sensing Microphone will be components of the OCS / Passenger Information System / Public Address System. OCS Engineering

Product Approval Approved 22/12/2015 AN-9001 TOA Corporation N/A Forms part of the OCS Public Address System, to improve customer audio clarity while minimising unnecessary loudness for nearby residences, and is to be used with exclusively with the DP-L2 Digital Ambient Noise Controller (TA 00117).

00119 2 Siemens TD84M Mk3 Trailable Dual Control Point Machine Point Machine Signals Type Approval Approved 18/12/2015 Refer to TA Certificate Siemens Germany

1) This Type Approval is for the Siemens TD84M Mk3 point machine, piece number 1335101601. Any subsequent models shall be reassessed for further Type Approval prior to use in the MTM rail network.2) Installers, maintainers and operators shall be cognisant of the safety warnings and pinch points of the TD84M Mk3 point machine, as contained in the Siemens Installation, Adjustments and Maintenance Guide [Appendix E, Doc 007].3) The TD84M Mk3 point machine shall be installed with a facing point lock (i.e. claw lock). 4) The switch blades shall be independent, that is, not connected to each other by spreaders (stretchers) or restrained by any mechanism other than the TD84M Mk3 point machine.5) The locking mechanism shall be designed for trail movements and allow independent blade movement sufficient to allow the closed blade to be unlocked prior to excessive flanging of the closed blade.6) A fixed label identifying that the point machine is a trailable type shall be visible to operators and maintainers.7) A fixed label identifying that the point machine must not be trailed when in hand shall be externally visible to operators and maintainers.8) MTM shall ensure that specific training for trailable point machines is added to the D84M point machine training procedure. The training procedure shall include inspections for wear and damage, lubrication, set up, adjustment and manual throw of points to check for binding in the turnout.9) MTM shall ensure that yard masters, shunters and maintainers are trained to always put the point machine back into motor after being in hand, and to always inspect the route prior to allowing moves.10) MTM should install signage on the relevant DOCU to advise drivers to fully complete moves where points are trailed. This mitigates the risk of trains setting back while points are disarranged.11) MTM should consider installing automatic rail lubricators in areas where TD84M Mk3 point machines are installed. 12) Installers shall test each specific turnout configuration by trail through tests (normal to reverse and reverse to normal).13) Installers shall ensure that the track gauge is within a tolerance consistent with an unlocking operation that does not place excessive flanging on the closed blade. Excessive over gauge of the rails will increase the distance of wheel set travel through the turnout before the unlocking stroke is completed and the closed blade released, leading to stress on both the blade and locking mechanism. 14) The turnout should be plated through both blades if on timber or other flexible bearers to minimise the potential to place a force on the lock and closed blade during trailing.15) For ideal operation, installers shall ensure that there is zero or minimal blade tension present. Excessive tension impacts on the lock retention in certain circumstances.16) Projects and maintainers shall ensure correct clutch spring is ordered for the turnout. The standard TD84M Mk3 point machine is fitted by Siemens with the “high” trail setting clutch spring (part number 4177300901), which provides a nominal 6 kN trail force.17) Testing of the claw lock mechanism for a turnout should be conducted with the TD84M Mk3 point machine in hand operation. This is recommended to prevent compromising the service life of the clutch by avoiding prolonged slippage during testing18) MTM should update their maintenance procedures for the use of trailable machines. In particular all areas around the blades need to be kept clean.19) Projects shall ensure that the lock interference on both the Normal and Reverse side are adjusted to the same or similar values for the points to be trailed reliably

00120 1 SpikeFast

Remediation of holes in timber sleepers and the remediation of seat abrasion on timber sleepers.Repair damage to timber sleepers. Repairing timber sleepers for re-gauging.

Track & Structures Type Approval Approved 13/04/2016 30/10/2016 ES-50 RM/RMII & ET-75 n/a n/a Willamette Valley Company USA

The Product shall be stored in ideal conditions and applied strictly in accordance with the manufacturers instructions, dispensing guidelines and curing rates/ The product shall not be used past its 'used by date,' as performance cannot be guaranteed. The product can cause eye, skin and respiratory burns. Use of PPE and safe handling instructions as outlined in the MSDS must be strictly adhered to. Mandatory training for of staff in the safe and correct use and handling of the product must be undertaken before practical field application. The product has restricted use where the timber condition is poor. Application shall be assessed by an experienced/qualifified track supervisor. Voids and holes must be filled correctly to ensure no air pockets are present. Adequate time must be allowed for the product to set before any drilling or boring is undertaken. A register of all sites shall be maintained during the trial period. During regular maintenance inspections, particular attention shall be paid to track gauge, lock spike and screw spike tension. And any other factors relating to movement on the sleeper of the rail or the plate. Any discrepencies observed shall be reported to the Track Delivery Manager. Prior to the expiry date for this TA, a thorough examination of all installation locations is to be undertaken. Particular attention shall be paid to the aforementioned factors, and photographs shall be taken to compare the before and after results, to determine the success or otherwise of the trial. ID to use the manufacturers guidelines as an interim procedure and ID to develop a detailed procedure that must be finalised after the successful completion of the trial period and confirmation by visual inspection that fastenings are holding and there is no movement under the train load.

00121 2 Hilti X-BT system Track Circuit Connections (M6, M8 and M10 stainless steel lug for electrical connections) Signals Type Approval Approved 15/08/2017 X-BT Hilti Lichtenstein

References contained within these conditions are made to "Hilti X-BT Threaded Fastener, Type Approval Submission"1) "The User" is the Project or Infrastructure Delivery Manager responsible for the application design and installation or maintenance of the Hilti X-BT Threaded Fastener system.2) The User is fully aware of and complies with the Product Information contained in the Type Approval Submission and references contained therein.3) To use this Approved product, the User shall comply with the conditions of this Type Approval and the items below: a) The Hilti X-BT fastening system shall only be used for track circuit connections. It is not to be used for any other rail bond application. Specifically the X-BT system is not to be used as a substitute for head-bond or traction bonding applications. b) The Hilti X-BT studs shall not be used for rail connections associated with impedance bond or negative traction return connections. c) Hilti X-BT studs shall not be installed within 50mm from each other (centre to centre). d) The Hilti X-BT studs shall not be installed within 62mm of a rail weld in 47kg or 53kg rail, or within 88mm of a rail weld in 60kg rail. e) The Hilti X-BT studs shall not be installed within 127mm of a bolt hole in 47kg or 53kg rail, or within 130mm of a bolt hole in 60kg rail. f) The Hilti X-BT studs shall not be installed on an uneven surface (i.e. where the rail is embossed). g) The pilot hole shall be drilled using the specified TX-OT 4/7-110 stepped drill bit. h) Where the Hilti X-BT stud is to be installed on the foot of the rail, it shall be installed using the appropriate rail jig, 30mm from the edge of the foot. The user shall refer to L1-CHE-SPE-181 - "Permanent Track Circuit Connections for Signaling Equipment" for clarification. i) Where the Hilti X-BT stud is to be installed in the web of the rail, it shall be installed using the appropriate rail jig, below the neutral axis in accordance with AS1085.1. The user shall refer to L1-CHE- SPE-181 - "Permanent Track Circuit Connections for Signaling Equipment" for clarification. j) The drilled pilot hole shall be clear of liquids and debris before the stud is inserted. k) After the hole has been drilled the stud shall be inserted within 30 minutes to prevent an oxide coating forming. I) Application shall be restricted to X-BT-ER M6/7 SN 4 Fasteners. m)The order of installation of the stud shall be sealing washer (against the rail), plain nut, cable lug, locking washer, plain nut. n) X-BT-ER M6/7 SN 4 fasteners shall be tightened to a torque of 10Nm to 20Nm. o) The powder cartridges shall be stored in dry conditions, within the manufacturer's packaging, and the correct disposal method followed through.

00123 1 iDS Cable Troughing Installation of signalling and comms routes without the need for excessive excavation. Track & Structures Type Approval Approved 14/01/2016 iDS FRD1, FRD2 & FRDP integrated Ducting Systems UK Refer to TA Certificate

00124 1 TechDRAIN T5 GeonetDrainage blanket to be installed beneath the structural fill layer of the track formation to capture and direct groundwater flow to the groundwater drainage system on each side of the rail cutting at Blackburn, preventing it from entering the rail formation.

Track & Structures Engineering Product Approval Approved 9/12/2015 TechDRAIN T5 GTG 512 Intermas Geosynthetics Spain

• This request for product approval shall ONLY apply for use of TechDRAIN on the Blackburn Rd grade separation project. Any request for further use at other locations, on the MTM network, shall be reassessed and a separate product approval application must be submitted. • The product must be installed strictly in accordance with the manufacturer’s installation guidelines for civil works.• Wide track vehicles should never ride directly over InterDRAIN unless a cover of soil >150mm is placed as a protection element for the geosynthetic layer.• It is not recommended to ride over the geocomposite with construction vehicles that use rubber tyres. Occasionally they may ride directly over it, in the planar areas (never in the slopes), reducing as much as possible the speed and avoiding any sharp turns and any fast accelerations or decelerations which may damage the geotextile• Penetrations in TechDRAIN Geonet, due to installation of OH and/or signal masts and drainage pits, must be adequately sealed to ensure design requirements are met.• Longitudinal drainage pits to be installed in 6 foot, as required for track drainage, shall be designed to ensure compatibility and functionality with the interface of the TechDRAIN drainage layer.

00125 1 AusTrak Full Depth Broad Gauge Concrete Guard Rail Sleepers Concrete Sleeper compatible with guardrail installation Track & Structures Type Approval Approved 22/12/2015 212-22B-e-GRA n/a n/a Austrak Australia

The Guardrail Sleepers shall be installed in a face. No interspersion with other sleeper type shall be permitted unless approved by the Chief Engineer.Guardrail Sleepers GR2 – GR8 shall be installed at 600mm centres as per manufacturer’s design. GR1 Sleepers shall be installed at 685mm centres.Installation on curves with radius < 400m will require an engineering review to evaluate applicable sleeper spacing.All componentry used shall be as specified by manufacturer and installed as per manufacturer’s instructions.

00128 1 Platform Gap Filler Mounted to coping to assist with passenger boarding trains Track & Structures Type Approval Approved 22/12/2015 48mm & 66mm Delkor Australia

1. The 48mm PGF shall be installed as an interim measure as a substitute for the preferred 65mm PGF. The 48mm PGF (with 15mm packing plate) may be approved to remain in place at the installed location, subject to a satisfactory trial period and proven performance in the field. A report on performance will need to be provided to justify this before a Full Type Approval is granted.2. The 48mm with (15mm packing plate) PGF shall be attached to the coping face using countersunk fastenings to ensure the head of fastenings does not encroach into the frangible area.3. The installation using bolts or studs with the head of fastening that protrudes beyond the PGF mounting bracket, must not be used to attach the PGF to the coping face.4. Where unsatisfactory performance has been recognised the 48mm PGF shall be replaced by the 65mm product.5. PGF’s are to be painted white with non-slip paint to match the platform coping

00132 1 FIN-LUBE Point switch plate lubricant Signals Engineering Product Approval Approved 22/12/2015 FIN-LUBE TF/EP and metal cleaner INTERFLON Netherlands Product to be used and stored in line with health and safety instructions outlined in the Material Safety Data Sheet (MSDS) and manufacturer specifications.

00135 1 Arthur Flury Low Speed Section Insulator Low speed areas only such as sidings, stabling yards, depots. Overhead Provisional Type

Approval Approved 14/07/2016 14/07/2017 Type FOK3 Low Speed Section Insulator - 655.300.046 N/A N/A Arthur Flury Switzerland Installation at Cragieburn Train Maintenance Facility as part of a 6 month trial. The design incorporating the proposed LSSI take into account its operating

parameters such as maximum line speed, tension etc which are available on drawing L9563

00137 1 Metrospec 38” Slimline Double Sided Passenger Information Display

The Metrospec 38” Slimline PID is an LCD panel allowing greater functionality and information for customers.The LCD panels are IP65 rated and are driven by a PC situated within the Panel.

OCS Engineering Product Approval Approved 8/04/2016 MS4238-1500

Graphics Firmware

20150914-SL4238V11

N/A Metrospec Australia Use on OCS Networks Only

00138 1 Plastream Steel Reinforced HDPE Pipe Steel reinforced HDPE pipe (SRP), either solid or slotted. Track & Structures Engineering Product Approval Approved 16/06/2016 Composite Drainage Pipe

Slotted Drainage Pipe N/A N/A Rocla AustraliaInstallation of pipe shall be in accordance with Plastream Steel Reinforced HDPE Pipe Installation Guide, AS/NZS 2566.2 and project specifications. The design and installation of Plastream pipes shall be completed by a qualified and competent engineer to demonstrate compliance to AS/NZS 2566.1. Loading calculations shall be provided for each project.

00139 1 Moxa PoE SwitchThe EDS-G512E-8PoE-4GSFP-T is part of the Moxa range of Industrial PoE switches. These devices are designed to provide gigabit switching and supply PoE power to remote devices over copper CAT5/CAT6 cabling.

OCS Engineering Product Approval Approved 8/04/2016 EDS-G512E-8PoE-4GSFP-T N/A N/A Moxa Taiwan Use on OCS Networks Only

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

00140 1 Industrial Etherenet ExtenderThese devices are designed to extend Ethernet networks over traditional twisted-copper pair cabling, over long distances (up to 15km, based on the quality of the copper cabling being used).

OCS Engineering Product Approval Approved 8/04/2016 DDW-142 N/A N/A Westermo Sweden Use on OCS Networks Only

00141 1 4G RouterThe Cybertec Model 2455 is a 4G router, and is able to provide secure remote connectivity via a VPN (virtual private network), supporting a number of encryption and connection options.

OCS Engineering Product Approval Approved 8/04/2016 2455 N/A N/A Cybertec Australia Use on OCS Networks Only

00142 1 Ballast Cage A Ballast Cage is a steel cage mounted to the top of a grated drainage pit to prevent ballast from covering/entering the pit and reducing its inlet capacity. Track & Structures Engineering

Product Approval Approved N/A Manufactured Australia

• Top of ballast cage to be installed 100mm above top of sleeper height• Site inspection prior to undertaking maintenance activities to identify and mark risks within the rail corridor (i.e. train stops, signal cables, existing pits, etc…)• Lid designed to be trafficable by construction / maintenance vehicles• Centre track ballast cage installed on inside of pit to maximise distance from edge of sleeper• Training & Awareness - MTM Infrastructure Staff to be made aware of this new type of pit and potential risk of damage during maintenance activities.• Pits with ballast cage to be added to Ellipse• All steel is hot dipped galvanized, for durability and general corrosion protection in accordance with -AS3679/1 - Structural Steel Hot Rolled Bars & Sections (Grade 300 Plus) -AS3678 - Structural Steel - Hot Rolled Plates, Floorplates & Slabs (Grade 250) -AS1163- Cold Formed Structural Steel Hollow Sections (Grade C450 Lo Galvanized) -AS/NZS1554 - Structural Steel Welding - Welding of Steel Structures -AS/NZS4680 - Hot-Dip Galvanized (Zinc) Coatings on Fabricated Ferrous Articles -AS1214 - Hot-Dip Galvanized Coatings on Threaded Fasteners• No fixings from ballast cage into reinforced concrete pit• Ballast cage isolated to minimise corrosion• Ensure O&M procedure specifies periodic general condition inspections of cages as part of drainage inspections• Use of standard pit and ballast cage sizes so they can be easily/quickly replaced• Maintenance staff to follow AC Train Infrastructure Electrical Safety Rules (high voltage rules) 1997• Install geofabric around the ballast cage when appropriate (i.e. where retrofitting poor condition ballast/ formation)

00143 1 Composite Station Platform

The Composite Station Platform is manufactured from fibre reinforced polymer (FRP) where glass fibres (aramid) are encased in a particular resin under high temperature.

The product is intended to compete with traditional methods of producing platforms (typical constructed insitu from steel, concrete and asphalt). Composite Station Platform panels are produced off-site and include all linemarking and tactical ground sensing indicators (TGSIs). The coping edge of the platform shall be produced as a standard product item, with custom made sections (also manufactured offsite) making up the remaining width of the platform.

Track & Structures Provisional Type Approval Rejected N/A Exel Composites Australia

00145 4 Frauscher Axle Counter Track Vacany Detection Signals Full Type Approval Approved FAdC-R2MTM - FAdC-R2

R2 approval Version 6

Frauscher Sensor Technology

1. MTM standards shall be complied with for Design and Installation of the axle counting system.2. That when integrated into a Westrace MkII via a WNC network, the Moviola Diagnostic System shall be configured to monitor the Axle Counter System as well as the Frauscher FDS system and that the interface communication parameters are fully documented and approved.3. The resetting of axle counters shall NOT be within the CBI, unless approved by the Chief Engineer or Delegate.

00147 1 ADS Pipe • Gravity and Low-Head water conveyance. • Groundwater/water table removal. Track & Structures Engineering

Approval Approved HDPE (various) ADS Various

•Installation of pipe shall be in accordance with ADS N12 Dual-Wall Corrugated HDPE Pipe Installation Guide, AS/NZS 2566.2 andproject specifications.• The design of ADS N12 Dual-Wall Corrugated shall comply with AS/NZS 2566.1. HDPE Pipe pipes • Any variation to the recommended cover will require a waiver and shall be submitted to the Chief Engineer for approval.

00148 1 Friction Buffer Stop The buffer stop is designed to bring trains to a complete halt in the available track. Track & Structures Full Type Approval Approved 29/07/2016 N/A N/A N/A Klose GmbH Germany

1. The friction buffer stops shall be designed in accordance with MTM End of Track Protection standard (MTST 0000002-08 L1-CHE-STD-032).2. Friction buffer stops are to be installed in accordance with Martinus installation & Maintenance Manual.3. Installation of buffer stops to be completed by trained personnel under supervision of Martinus Representative. 4. Buffer stop to be designed fit for purpose and in accordance with the Martinus Rail Design Criteria Form.5. MTM Track certification required post installation.6. Following the resetting and adjustments after damage caused by a train strike the buffer stop is to be recertified prior to re-use.7. Friction buffer stop details to be entered into Ellipse (incl. location, sliding distance, and Installation and Maintenance Manual).8. MTM ID to incorporate the Martinus Buffer stop into the TMP for buffer stop maintenance and inspection.9. Routine inspection and maintenance to be undertaken as per Martinus Installation & Maintenance Manual until the requirement of item 8 (above) is completed.

00149 1 Siemens Simatic IPC

The product is proposed for, but not limited to the NMCR project, which will be used as protocol converter and/or Technicians Maintenance Terminal i.e. MoviolaWThe product is a PC, which hardware is designed for industrial environment, SRA proposed to be implemented as Control System equipment as a non-vital equipment.For the MoviolaW and CSPC applications, SRA propose to deploy the hardware using either the standard Microsoft Windows 7 or Linux environments.

Signals Full Type Approval Approved 20/06/2016 IPC 427D N/A N/A Siemens Germany

Intended Application 1: Protocol Converter (CSPC) : This device is only approved for operation in equipment rooms in order to comply with the environmental requirements: The device must be installed with clearance of at least 100mm from the interfaces and at least 50mm from the non-interface sides. The device must be equipped with a CFast card, HDD or SDD. The storage media must be certified with a temperature rating of 55 degrees or better. The device must be equipped with an expansion cubicle. The device must be specified with: Intel Core i3-3217UE 1.6 GHz, 3 MB SLC and 4 GB DDR3-ECC SODIMM. Intended Application 2: MoviolaW Work Station - The device is only approved for operation in equipment rooms in order to comply with environmental requirements: The device must be installed with clearance at least 100mm from the interfaces and at least 50mm the non-interface side. The device must be equipped with a CFast card, HDD or SDD. The storage media must be certified with a temperature rating of 55 degrees or better. The Device must be equipped with an expansion cubicle. The BIOS > Power > Turbo Mode Level must be set to 'Temperature Optimised.' The Device must be specified with: Intel Core i7-35117UE 1.7 GHz, 4 MB SLC and 4 GB DDR3-ECC SODIMM

00150 1 AEG “Protect” Uninterruptible Power Supply Range

The AEG UPS is a modular system which combines the AEG Traction Rectifier and AC UPS Protect 8.31 products to provide single-phase input capability to suit the characteristics of the 2.2kV MTM signal power network. The system is comprised of a 60kVA industrial UPS with single-phase output augmented by a modular switch mode traction rectifier to take in a single phase supply. Multiple 60kVA UPS modules can be paralleled to provide higher capacity systems.

Electrical Networks Provisional Type Approval Approved 27/09/2016 23/10/2017 Traction rectifier 384V/Protect 8.31 60 8.31 60-415-384-

240-H20

Inverter CE1CW34P.Dy2

Bypass CE1CE50H.DY4

Rectifier CP1CG21J.D07Communication

PP1MC41Q.D01Firmware:CE1YY

18R

AEG Power Solutions Germany

Where phase dependent signal equipment is present this equipment can only be placed into service when installed with independent check sync protection relay and with external synchronisation available. The unit must always be installed with the AEG proprietary LBS included. This will likely impact on the firmware and software versions provided by AEG.

Under no circumstances can the UPS be allowed to ‘free run’ on its internal 50Hz clock oscillator where phase dependent signal equipment is present.

FAT must include for LBS synchronisation testing. Site acceptance testing must be conducted which includes for failure scenarios, confirms UPS isolation and prevention of the UPS from free running, where phase dependent signal relays are present, when either operating on static bypass or LBS reference.

MTM Signals must be consulted and form part of the installation planning where a new UPS is being installed.

This equipment must be fully tested and commissioned with detailed test plans before being placed into operational service.

The UPS is installed with the SEL relay protection scheme and “double knock circuit “

00151 1 Extreme ISW 8GbP, 4-SFP, PoE Switch Provide a layer 2 Ethernet network and supply PoE power for CCTV, access control and sensor devices in the MURL. It is also expected that this switch will be deployed at stations, as part of a standard FLS switch.

OCS Type Approval Approved 27/07/2016 Extreme 16804 (ISW 8GbP,4SFP) N/A N/A Extreme Taiwan Use on OCS Networks Only

00152 1 Solar Powered LED lighting.

Leadsun Systems are designed to be ‘All in One’ providing an aesthetically pleasing totally self-contained unit with all control, battery and lighting maintained at pole height reducing the possibility of damage and vandalism. A total range of LED lights up to 60W can provide secondary type lighting for applications such as stations, carparks, pathways and facilities. A combination of Solar Engines and LED Lights with alternative distribution Patterns would be offered depending on layouts. All system designs will be based on compliance to AUS standards, with CAD software to detail lighting design intensity levels.

Track & Structures Type Approval Withdrawn (300-1, 300-UTS) VOSSLOH GERMANY

00154 1 Vertaic Bollard

Solar powered bollard500 lumen operationVandal resistantNo cabling required

Track & Structures Type Approval Withdrawn M10-1SP Valen Light USA ( AUSTIN TX ) Refer to Correspondence within case number

00156 1 Siemens Vandal Resistent Trainstop

This is an incremental Provisional Type Approval from the existing JAH to the Siemens Trackguard Trainstop, Style JAV.

The JAH was originally Type Approved by PTC as TAC87/98 and is currently approved by MTM via Grandfather Rights Approval (no available Certificate).

A trial of the JAV in revenue service will be conducted to demonstrate the vandal resistant features of the JAV. It is proposed to replace the existing C209V at Royal Park with the JAV. The trial location will be finalised and full details shown in a “Trial Report” document which will be produced after this Provisional Type Approval is completed.

Signals Provisional Type Approval Approved 15/07/2016 31/12/2016 Part Number:- 390102001 390102001 N/A Siemens Australia

1) The Provisional Type Approval is valid for the trial period which shall be concluded and removed from service by the 31/12/2016.2) All staff involved in the installation, set to work, test and commission and maintenance activities during the trial must be fully briefed on the Siemens JAV Trainstop prior to entering the worksite.3) Design, Installation and T&C of the trial site shall be performed in accordance with the relevant VRIOGS.4) A CDS Logger shall be connected to monitor and log Trainstop performance.5) Infrastructure Maintainers shall ensure that equipment is maintained in accordance with equipment manufacturer’s recommendations detailed in the interim “Siemens Trainguard JAV Vandal Resistant Trainstop Installation and Field Maintenance Guide” Issue 0.2.6) Infrastructure Signals Delivery Manager shall ensure that all staff required to use the equipment are suitably trained and have the required competency.7) Siemens shall update and issue their interim “Siemens Trainguard JAV Vandal Resistant Trainstop Installation and Field Maintenance Guide” Issue 0.2 (tttnjav_0.2.pdf) as final before the trial commences.8) Using the results of the JAV trial, Siemens shall complete and issue their “V&V and Safety Assessment” before Full Type Approval is approved.9) Siemens shall update and issue their “Siemens Trainguard Trainstop, Style JAV, Application for Type Approval of JAV Trainstop for use on MTM’s network” Issue 3.0 dated 29/06/2016 (TTA JAV Type Approval MTM.pdf) as final before Full Type Approval is approved.

00157 2 Siemens Tilt Mast

This Type approval has been performed to create an alternative to MTM-FTA-00116(2) RIC Tilt Mast.

The scope of this Type Approval application is limited to the Siemens Easy Access Signal Mast for use on the MTM network for signal mast and other mast applications.

The signals and associated mounting hardware (e.g. front of post brackets) are not included in this Type Approval.

This type approval does not include a detection switch in the tilt mechanism to indicate the position of the Siemens Easy Access Signal Mast.

Signals Full Type Approval Approved 22/11/2017 na

Refer to Appendix 1 in hyperlink. Note: Existing Siemens Part Numbers: Masts:

1175104003/1175104004/1175104007/1175104013/1175104014. Counter Weights:

3175308301/3175308302

Refer to Appendix 1 in

MTM-FTA-0157(1) - Type

Approval Recommendatio

n

N/A Siemens Australia

Conditions:-References contained within these conditions are made to “Siemens Easy Access Mast Full Type Approval for MTM Evaluation Report” version 1.0 dated 18/07/2016.

1) “The User” is the Project or Infrastructure Delivery Manager responsible for the application design and installation or maintenance of the Siemens Easy Access Mast.2) The User shall ensure that he/she is fully aware of and complies with the Product Information contained in “Siemens Easy Access Mast Full Type Approval for MTM Evaluation Report” version 1.0 dated 18/07/2016 and references contained therein.3) The User shall comply with the Manufacturer’s recommendation that the Siemens Easy Access Mast not be operated in wind conditions above 24km/h. Refer to “FEA Report” 1751-054 Rev A (Appendix E Doc 21).4) The User shall supply a hand held wind meter for staff performing installation or maintenance that requires the Siemens Easy Access Mast to be lowered and raised, to ensure safe operation in wind speeds less than 24 km/h.5) The User shall ensure that internal signal cable(s) are protected by flexible corrugated plastic conduit near the mast pivot, to prevent possible damage.Application Design and Installation6) To use this Type Approved product, the User shall require an application design which shall be reviewed and accepted by the Head of Engineering, Signals. The design submission shall be based on the Manufacturer’s drawing 1751-040 Rev 21.0 (Appendix E Doc 3) and shall consist of detailed dimensioned plan and cross-sectional DMS compliant drawings which demonstrate compliance with the conditions of this Type Approval and full details of:-a) The signal installation in both the raised and lowered positions in relation to the track, structure gauge and ground level. b) Safe operation of the mast including but not limited to, clearances to other structures, power lines etc. and balancing to minimise operator effort.c) The fitted signal shall not encroach on the track structure gauge, other structures, power lines etc.d) An adequate working surface level to the baseplate of the Siemens Easy Access Signal Mast, to allow safe and convenient access to all equipment on the Siemens Easy Access Signal Mast when in the lowered position (Refer to Manufacturer’s drawing 1751-040 Rev 21.0 Installation Note No.4). On embankments and in cuttings, retaining walls and/or hand rails shall be provided where necessary for statutory compliance. All such structures shall be clear of the working surface.e) The level working surface shall extend 1200mm beyond both the bottom and top of the fitted signal when in the lowered position, to provide sufficient work space.f) The signal foundation shall be provided in accordance with STD_G0074 Rev A “Signals Standard Foundation Signal Masts”.g) The User shall provide calculations demonstrating that the chosen foundation is sufficient to support the fitted signal considering the ground conditions and a maximum wind loading of 160km/h, in compliance with “FEA Report” 1751-054 Rev A (Appendix E Doc 21).h) Full signal sighting details as required by the Signal Sighting Committee, to enable the Signal Sighting Committee to sight the signal.i) The Siemens Easy Access Signal Mast shall be installed in compliance with the Manufacturer’s requirements contained in M574-02 Issue 3.0 “Use, Installation and Maintenance” (Appendix E Doc 11).Maintenance Use

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

00158 1 Phoenix Contact updated on 22/11/2017 to capture 5.5metre masts OCS Engineering Approval Approved 13/07/2016 MINI-PS-48 6-DC/24DC/1 N/A N/A Phoenix Contact China Nil

00159 2 Meanwell Basic 240v to 24vDC power supply. Intended use is to power industrial PCs and network equipment such as 4G routers. Input Range is 100-240vAC. Temperature Range is -20 -50 ambient

OCS Full Type Approval Approved MDR-40-24 N/A N/A Meanwell China Nil

00160 1 Siemens S60 Boom Mechanism & S40 to S60 Conversion Kit Withdrawn

Type Approval is being rescinded due to a maintenance issue. Not to be used in any future works.

00163 1 Treadwell FRP Fence Assembly

The Treadwell fence assembly is made from a fibreglass reinforced plastic (FRP) which is composed of a matrix of plastic augmented by fine glass fibres usually formed by the process of moulding. The weight and strength of FRP materials are comparable to those of conventional materials such as aluminium and steel. Upright posts can be positioned up to 2.3m apart. The fence panel stands at 3m tall with spikes cut along the top section.

Structures Full Type Approval Approved 19/05/2017 ArchitEX Treadwell Australia

Treadwell FRP fences shall:• Be assembled using only the Treadwell FRP fence components covered by this Type Approval.The minimum height of the fence shall be 2.5 metres above the adjacent ground level and constructed in accordance with the requirements of AS 2067 except that razor wire shall be used in place of barbed wire at the top of the fence.

00167 2 Dahua IP CCTV CameraAn IP Camera with H.264 1080p, PoE, and basic on-board analytics.ONVIF compliantWill be used with Dahua branded lenses, but is compatible with C/CS lenses.

OCS Engineering Approval Approved 15/05/2017 DH-IPC-HF8281EP N/A N/A Dahua China None

00168 1 Vossloh 300 series slab track fastening system

The Vossloh 300 series fastening which is the world’s most popular on slab track – it offers a range of handling, install and maintenance benefits since it is mounted directly to the precast without the need for a baseplate giving significant cost reduction. There is also the possibility of pre-assembly of the components on the precast concrete to aid installation onsite. Since the components are all retained the components cannot come loose so there is opportunity to increase efficiency and reduce life cycle costs during rail installation and replacement.

Track Full Type Approval Approved 23/06/2017 (300-1, 300-UTS) N/A N/A Vossloh Germany

1.The System 300-1 is approved for use on Direct Fix track. Variants should be considered for ballasted track subject to demonstration of compliance with MTM sleeper and resilient fastening requirements.2. System 300-1 shall be installed in accordance with manufacturers’ installation guidelines.3. For major works MTM reserve the right to request construction of one or more demonstration or test sections ahead of the main works. These will be used to confirm performance of the proposed trackform in accordance with agreed criteria which may include sub-component conformance testing, constructability, installation quality, maintainability and operability with signalling systems which may include axle counters, TPWS, Audio frequency track circuits or others.4. 4. Any use of the System 300-1 shall be supported by an agreed track design specifying the required clip toe load, rail pad stiffness and interface transitions with the adjoining track. Designers shall demonstrate that the proposed product configuration will meet MTM’s functional requirements and agreed noise and vibration requirements on a case by case basis.5. Provision of spare components, materials and special tools shall be agreed with MTM infrastructure on a case by case basis for each project.

00170 1 Vossloh Precast Plinth

The Vossloh Precast Plinth track system is an evolution of the typical in-situ plinth slab track construction method where the precast enables reduced site works, greater installation accuracy and increased install rates. The precast includes an integrated concrete upstand or ‘kerb’ for derailment containment.

Track Full Type Approval Approved 11/10/2017 VPP-CBG-1 N/A N/A Vossloh Germany

1. The VCA Plinth shall be installed in accordance with manufacturers installation guidelines.

2. The VCA Plinth shall be compatible with the trackform that has the following characteristics :o 23 TAL at 115km/ho 25 TAL at 80km/ho 115 km/h max. design speed (80 km/h max. operational)o Max. cant of 40mmo 50 year design life in accordance with AS3600o Vossloh 300 Fastening system at 685mm spacing.

3. Interface connections between the underside of the plinths and the deck shall be in accordance with an approved structural design and warranted as fit for purpose by an MTM approved proof engineer. The design must accommodate expected variations in deck surface level.

4. To ensure correct operation of Audio frequency circuits, plinths and the concrete interface connections shall contain no enclosed metallic loops within 500mm of the top of rail.

5. Integrated upstands must be installed on the gauge side of both running rails wherever it is reasonably practicable to do so. Any gaps or discontinuities between plinth units shall be minimised and treated to MTM’s approval.

6. Provision of spare components, materials and special tools shall be agreed with MTM infrastructure.

7. The production, handling, storage and delivery of the plinths shall conform to Quality Control and Quality Assurance procedures reviewed and accepted by MTM.

8. Design ULS lateral derailment load shall not exceed 138kN when applied to the top of the upstand.

9. The configuration of the plinth system shall allow for placement of signalling equipment to MTM standards and Standard plans, with capture of infrastructure requirements for access and egress to that equipment. And a full and detailed “Rail System Components” report shall be provided to MTM for MTM Engineering approval prior to final construction of plinth.

00171 1 Siemens DC-DC Converter for S40 & S60 DC-DC converter for S40 or S60 level crosssing boom mechanisms Signals Full Type Approval Approved The User shall ensure that he/she is fully aware of and complies with the Product Information contained in MTM-FTA-00171 Issue 1 dated 22/09/2016 and

references contained therein.

00172 1 Siemens Type 8DJH range medium voltage switchgear

The Siemens 8DJH switchgear is factory-assembled, type-tested, 3-pole metal-enclosed single-busbar switchgear for indoor installation. Substations Provisional Type

Approval Approved 17/11/2016 8DJH-121509 N/A N/A Siemens China•24 month trial.•Assessment of in service performance

00173 1

SoundWeb Londons-BLU800 Master DSP;

-BLU100; -BLU-BIB; -BLU-Dan

MTM is looking to introduce an IP based PA system which allows for greater flexibility in the area of recordings and announcements.The new PA system will be connected via the Metro Trains Security Network. A general configuration of the PA system will comprise the below listed products. 1. Soundweb London BLU800 Master DSP (TA-00173)2. Soundweb London BLU100 (TA-00173)3. Soundweb London BLU-BIB (Break-In Box) Input Expander (TA-00173)4. Soundweb London Blue-Dan (Networked Signal Processor) (TA-00173)5. TOA SX2000 Paging Matrix System (TA-00174)6. TOA RM200SA Paging Station (TA-00174)

OCS Engineering Approval Approved Use at Flinders St Station only

00174 1 TOA SX2000 Paging Matrix System and TOA RM200SA Paging Station

MTM is looking to introduce an IP based PA system which allows for greater flexibility in the area of recordings and announcements.The new PA system will be connected via the Metro Trains Security Network. A general configuration of the PA system will comprise the below listed products. 1. Soundweb London BLU800 Master DSP (TA-00173)2. Soundweb London BLU100 (TA-00173)3. Soundweb London BLU-BIB (Break-In Box) Input Expander (TA-00173)4. Soundweb London Blue-Dan (Networked Signal Processor) (TA-00173)5. TOA SX2000 Paging Matrix System (TA-00174)6. TOA RM200SA Paging Station (TA-00174)

OCS Engineering Approval Approved Use at Flinders St Station only

00177 1 Forked Collar Socket

The forked collar sockets are designed with a breaking load of greater than 80kN. The forked collar sockets have been independently tested by ALS Global and a breaking load of ~100kN was recorded. The maximum working load for the forked collar socket will be 20kN.

Overhead Full Type Approval Approved

• Bonomi product number: 15195103 for use on 181mm2, 17.5mm dia. 37/2.5, HdCu catenary wire.• Bonomi product number: 15197029 for use on 161mm2, 16.27mm dia. 37 strand, HdCu catenary wire.• Bonomi product number: 15195104 for use on 161mm2, 15mm dia. HdCu contact wire.

N/A N/A Bonomi Italy

• Bonomi part number and conductor diameter to be stamped on the body of the Forked Collar Socket.• On the catenary wire body (part number 15199 5107), the distance from the end of the forked collar socket to the centre of the cuphead pin to be reduced from 30mm to 25mm to allow for attachment to the existing overhead wiring infrastructure.Split pin to be replaced with a humpback pin prior to delivery.

00178 13.8/6.6 kV 3 core - 35mm2 Copper

Conductor XLPE Insulated cable

35mm2 Cable for 3.3kV Essential Services Distribution System Substations Full Type Approval Approved 30/11/2016 14317111.01 N/A N/A Prysmian Group Australia The Manufacturer is to label each core with the numbers 1, 2, and 3 or R, W, and B.

00179 13.8/6.6 kV 3 core - 35mm2 Copper

Conductor XLPE Insulated cable

35mm2 Cable for 3.3kV Essential Services Distribution System Substations Full Type Approval Approved 30/11/2016 XHHP18RD003OMAA N/A N/A Nexans (Olex) China The Manufacturer is to label each core with the numbers 1, 2, and 3 or R, W, and B.

00180 1 22kV/400V Essential Services and Auxiliary Transformer

Supply of Essential Services UPS and auxiliary loads from 22kV supply within a substation or switchyard. Substations Provisional Type

Approval Approved 30/11/2016 30/05/201831727 (100kVa, 22kV)31730 (200kVa, 22kV) N/A N/A TMC Australia

Alteration of winding vector to Dyn1 in GA drawing title blocks.

Provision of completed Technical Data Schedules for the transformers and acceptance of these schedules as appropriate.

Type tests as specified in AS60076 conducted and results approved by MTM Engineering.

Standard drawings for product (General Arrangement and Nameplate) produced in PTV compliant format and booked into DMS.

00181 1 400V/3.3kV Essential Services Step-up Transformer Suitable for cable entry and exit, indoor or outdoor installation. Substations Provisional Type

Approval Approved 30/11/2016 30/05/2018

TMT110603300 (60kVA)TMT111203300 (120kVA)TMT111803300 (180kVA) N/A N/A TMC Australia

Satisfactory detailed design package approved by MTM Engineering including shop drawings and precise nameplate details.

Type tests as specified in AS60076 conducted and results approved by MTM Engineering.

Standard drawings for product (General Arrangement and Nameplate) produced in PTV compliant format and booked into DMS.

00182 1 AEG Protect 8.33 Essential Services Distribution System Supply UPS Supply of 3.3kV Essential Services Distribution System from 400V UPS output. Substations Provisional Type

Approval Approved 30/11/2016 30/05/201870151774/001 (Protect 8.31 20-400-216-230)70152034/002 (Protect 8.33 40-400-384-400) N/A N/A AEG Power Systems Germany

Synchronisation R&D completed successfully or clarification of existing synchronisation functionality.

Satisfactory detailed design package to be completed and approved by MTM Engineering

Standard drawings for product to be produced in PTV compliant format and booked into DMS.

Installation of batteries within climate controlled rooms to ensure an average ambient temperature of 25°C.

00183 2 Eaton Xiria Essential Services Distribution System Switchgear

Supply of 3.3kV Essential Services Distribution System via a compatible step up transformer Substations Provisional Type

Approval Approved 13/09/2017 30/11/2018 TBA N/A N/A Eaton Germany

Confirmation of desired standard 3 way bus configuration during detailed design process.Installation of switchgear assembly to be such that access to the rear is prevented during operation.Installation to be restricted to locations where the maximum prospective fault current is no more than 2000A.Installation to include separate electrical control and indication panelUsage of the switchgear on the Essential Services Distribution System requires remote control and indication via the MTM SCADA system.Satisfactory detailed design package to be completed and approved by MTM Engineering including standard installation arrangements.Standard drawings for each panel type to be produced in PTV compliant format and booked into DMS.

00184 1 Schneider Premset Essential Services Distribution System Switchgear

Protection and switching of Essential Services Distribution System feeders and supply transformers when used in conjunction with an appropriate SCADA control system and installed within a substation.

Substations Provisional Type Approval Approved 30/11/2016 30/05/2018 D06H, I06T, G06, D06H-NE N/A N/A Schneider France

Satisfactory detailed design package to be completed and approved by MTM Engineering.

Submission of compliance statement relating to no requirement for arc venting at 2kA fault levels.

Standard drawings for each panel type to be produced in PTV compliant format and booked into DMS.

Sleeved cable markers to be provided on cables within the control compartment.

Hooks or clips for storage for operating handle to be provided near to switchgear.

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

00185 1

IEI Tank 820 PC - A durable fan-less Embedded PC constructed of

aluminium alloys and designed with various expansion interfaces, giving the

ability to add PCI/PCIe expansion boards.

The product will be utilised as a fan-less PC for the TCMS Fringe Box applications. While the product is capable of operation as a fan-less PC for other purposes, other uses will require amendment to the Type Approval.

OCS Engineering Approval Approved TANK-820-H61-i5/2G/1P2E-R22 N/A N/A IEI USA Intended Application -OCS Signalling Networks- TCMS Fringe Box Applications

00186 1 Single Phase Signal Power Supply Transformers

Supply of 110V signalling loads from the 3.3kV Essential Services Distribution System when connected to Essential Services Trackside Switchgear conforming to MESP 041000-01 and mounted within a suitable secured and weatherproof enclosure or building.

Substations Provisional Type Approval Approved 28/11/2016 28/11/2018

TMT120033300A (3kVa 3.3kV)TMT120063300A (6kVA 3.3kV)

TMT120103300A (10kVA 3.3kV)TMT120153300A (15kVA 3.3kV)TMT120203300A (20kVA 3.3kV)

N/A N/A TMC Australia

Satisfactory detailed design package approved by MTM Engineering including completed technical data schedule, shop drawings and precise nameplate details.

Type tests as specified in AS60076 conducted and results approved by MTM Engineering.

Standard drawings for products (General Arrangement and Nameplate) produced in PTV compliant format and booked into DMS.

00188 1 Three Phase Essential Services Load Transformer 3300/400V AC

Supply of 400V Essential Services loads (as defined in L1-CHE-SPE-154) from the 3.3kV Essential Services Distribution System when connected to Essential Services Trackside Switchgear conforming to MESP 041000-01 and mounted within a suitable secured and weatherproof enclosure or building.

Substations Provisional Type Approval Approved 28/11/2017 27/11/2018

TMT130063300B (6kVa 3.3kV)TMT13010330B (10kVA 3.3kV)

TMT130203300B (20kVA 3.3kV)TMT130323300B (31.5kVA 3.3V)

N/A N/A TMC Australia

Satisfactory detailed design package approved by MTM Engineering including completed technical data schedule, shop drawings and precise nameplate details.

Type tests as specified in AS60076 conducted and results approved by MTM Engineering.

Standard drawings for products (General Arrangement and Nameplate) produced in PTV compliant format and booked into DMS.

00190 1 THYCON MPX Industrial UPS

The MPX UPS comprises the following major components:• Input Circuit Breaker – this provides the point of isolation & protection to the rectifier.• Rectifier – converts the incoming AC to DC. It supplies DC power to the Inverter and to the battery bank.• Battery Circuit Breaker – this provides a point of isolation between the battery bank and the Inverter/Rectifier. The battery circuit breaker includes an automatic under voltage release that isolates the batteries whenever the inverter is shutdown.• Battery Bank – this provides the energy for the UPS inverter to survive disturbances to the incoming AC mains supply.• Inverter – to convert DC to AC power• Reactive Compensator – to provide reactive power• Dzn0 Output Transformer – this provides galvanic isolation between the UPS Inverter and the output supply. It provides a clean neutral for the UPS load, while prevent balanced triplen harmonic currents from returning to the input. • Output Circuit Breaker – this provides protection to the UPS inverter in the event of a fault.• Static Switch – this ensures supply is maintained in the event of a Inverter fault. It also provides an alternative source of fault energy to clear downstream load faults.

Substations Provisional Type Approval Approved 4/08/2017 MPX 50 through to MPX 200 N/A N/A Thycon Australia

Synchronisation input shall be provided in accordance with MTM requirements to permit paralleling (normal switching practice).Unit shall be configured such that when no synchronisation reference is available the load is dropped, subject to a site specific risk assessment.Independent sync-check protection shall be providedShall be used in conjunction with an Auxiliary and Essential Services Transformer in conformance with MESP 050100-01.Satisfactory detailed design package (shop drawings) shall be approved by MTM Engineering.Standard drawings for product shall be produced in PTV compliant format and booked into DMS.Sound level testing shall be completed by independent body and results to confirm performance is in line with specification.Testing of Short Circuit Performance shall be undertaken on the first unit of each type.Batteries shall be installed within climate controlled rooms to ensure an ambient temperature of 25±5°C.Field testing for compatibility with existing equipment and synchronisation solution shall be completed prior to use of the equipment during normal running.MTM maintenance and operating documentation shall be produced prior to commissioning.An Inspection and Testing Plan for the installation of unit shall be approved by MTM Engineering.Hardware and software versions used during commissioning testing shall be recorded and shall not be changed without the consent of MTM Engineering.

00191 2 Pfisterer TENSOREX Tensioner C+

The Tensioner C+ manufactured by Pfisterer is an overhead wiring spiral spring based tensioning device which applies a constant tension to the overhead conductors throughout a given temperature range. The Tensioner C+ performs the same function as the existing balanced weight wheel assembly and will be used as an alternative product.

Overhead Provisional Type Approval Approved

750/2000 4S, part number 000700434-DB1203750/1500 3S, part number 000700433-DBS1203750/1500 3S, part number 000700433-DB1203

750/1000 2S, part number 000700441-DBS1203N/A N/A Pfisterer Germany

00192 1 161mm2 Hard-drawn Copper Contact Wire

Contact wire is used to provide traction power to the trains. The contact wire manufactured by Isodraht is identical to the contact wire MTM have been using since the 1910’s. Isodraht will be used as an alternative manufacturer to the MTM’s existing supplier Lamifil.

Overhead Full Type Approval Approved 30/03/2017 N/A N/A Isodraht GmbH Germany

00196 1 Siemens Helios Sine Wave Inverter Used to provide 110V clean power for Westrace MkII LOM Cards Signals Full Type Approval Approved 16/01/2017 RSI 200-2A50F3P-S8347 NAHelios Power Solutions P/L

Unit 6 / 2-8 South St,Rydalmere NSW 2114

Helios Power Solutions P/L Refer to Type Approval Certificate

00197 1 FireMaster Fire Compartmentation / Smoke Compartmentation for all buildings Structures Full Type Approval Withdrawn FM N/A N/A Coopers Fire UK & Australia

00198 1 RMP Use as edge profile cladding on the outside of the viaduct in all areas on LXRP-CTD. Structures Engineering Product Approval Approved 8/02/2017 N/A N/A N/A Viscount Rotation Moulding Pty

Ltd Australia

00199 1 GRC Use as edge profile cladding on the outside of the viaduct in all areas on LXRP-CTD. Structures Engineering Product Approval Withdrawn N/A N/A N/A ASURCO Contracting Pty Ltd

& GRC Environments Pty Ltd Australia

00202 1 Chemset Reo 502

It is to be used for fastening the sleeper anchor bolts in the MURL.Can also be used for reinforcing bars, deformed bars, starter bars, anchoring structural steel to concrete, rail sleeper repair, rail gantries, road stitching, light poles Structures Engineering

Approval Approved 28/08/2017 N/A N/A N/A Ramsetreid Australia

• Application and Handling of Chemset Reo 502 shall be in accordance with Manufacturer’s instructions. Refer to Chemset Reo 502 Technical Data Sheet and Chemset Reo 502 Material Safety Data Sheet.• Chemset Reo 502 shall be utilised for anchoring hold-down bolts in both direct fixation and double sleeper arrangements only. Any extension to this will require a revision to the Type Approval. • The shelf life of Chemset Reo 502 shall be 12 months from date of manufacture stored in a cool, dry place between 5°C and 25°C away from direct sunlight as per Chemset Reo 502 Technical Data Sheet (Page 3).• Cure Times for Chemset Reo 502 shall be in accordance with Working and Loading Times Table specified in Chemset Reo 502 Technical Data Sheet (Page 2).

00203 1 Multidcut - HDPE based troughing system Mounting to structures for combined Service Route. Structures Full Type Approval Approved N/A N/A Cubis Systems Ireland

• The Multiduct product is only to be used over bridges • The Multiduct product requires the endorsement for use in each location by the Chief Engineer• Ensure that the pits on either side of the bridge and to which the Multiduct enters are the standard pits used by MTM• “Danger HV” label to be placed securely on every section carrying HV cables• The arrangement and separation of cables follow MTM Specifications L1-CHE-SPE-070 High Voltage Cable Routes• Ensure the support brackets and connections to the structure are hot dip galvanised and can carry the anticipated loads (and have future capability for more cables) from the troughing system.

00204 1 Weidmuller PROmax 960W 24V 40A

This supply has a smoother and better regulated output than the current Ironcore solution which it is replacing. It is also smaller, which offers increased design utility and decreased manual handling risk. Additionally, it is far cheaper than the Ironcore solution. For use with Siemens S-40 and S-60 Boom Mechanisms alongside the accompanying Siemens DC/DC converters.

Signals Full Type Approval Approved 24/07/2017 N/A N/A Weidmuller Germany

References contained within these conditions are made to "Full Type Approval Report Weidmuller" version 1 dated 21/07/2017.1) The user shall ensure that he/she is fully aware of and complies with the information given in "Weidm0llerPROmax 960W 24V 40A Operating Instructions".2) Any changes to the Weidm0ller PROmax 960W 24V 40A power supply shall be detailed to MTM.3) Weidmuller shall retain ISO 9001 accreditation and inform MTM of any change in accreditation.4) Spare units are to be kept at critical store locations to ensure that any faults that occur can be rectified as soon as possible.5) To indicate a failure, the indication relay output shall be used where possible.

00205 1 Siemens LED Tricolour Signal To be used as another option for installation in situations where LED modules are installed. Signals Full Type Approval Approved 28/08/2017 N/A N/A Siemens Mexico

1) When a UGL MK3 Tricolour LED TC2 Signal Module Version 10A is installed on a signal post with 212mm A and B arms, both arms shall have the same signal model installed. This is to provide consistent signal luminance of signals on the same post.2) Where UGL becomes aware of any unsafe failure modes (i.e. any mode which may compromise SIL-4 requirements) which affect equipment of this type, MTM shall be notified and any retrofit must be provided by UGL, free of charge.3) The UGL MK3 Tricolour LED TC2 signal case used shall allow for installation/replacement and inspection from the rear of the case.4) The red aspect, with back relay contacts, shall NOT be double cut, to provide a greater fail safe function to a more restrictive aspect. An exception to this condition is made with respect to LED conversion kits where the red aspect is double cut as a default configuration.5) When UGL perform incremental changes to the product, UGL shall inform MTM. Minor incremental changes, considered version changes by UGL, will also fall under this Type Approval subject to the discretion and review of MTM.

00206 1 53kg 4 hole insulated fishplate (modified from 6 hole insulated fishplate)

Modified Westray 4 hole insulated fishplate will be used at locations, particularly within P&Cs, where 6 hole fishplates cannot fit. MTM currently uses 1939 Victorian Railways 4 hole Mechanical IRJ at these locations. MTM to supply own insulation kit for installation of joint dependent on a dry run off track to determine compatibility.

Track Full Type Approval Approved CP522-1 N/A N/A Westray Engineering Australia

1. 4 hole Westray insulated fishplate is to be installed with existing insulation kits in use on MTM network2. 4 hole Westray insulated fishplate is to comply with requirements of AS 1085.2-2002 Railway track material Part 2: Fishplates3. 4 hole Westray insulated fishplate shall only be installed in and around points and crossings to replace an existing 4 hole mechanical joint where a siz hole joint cannot be fitted due to space restriction. Size, location and condition of bolt holes must be checked prior to installation.Note: Drilling pattern is compatible4. 4 hole Westray fishplates are NOT permitted in CWR on mainline open track.5. 4 hole Westray fishplates are NOT permitted in new 60kg mainline track and turnouts.6. Rail ends must be square and not battered or dipped and if possible ultrasonically tested in accordance with Section 3.3. of MTIM 030600-01.7. Surface of the rail must be clean and free from dirt, rust and scale in accordance with Section 3.3 of MTM 030600-01.8. Where 4 hole Westray joints are installed; ensure allowance for expansion is provided in accordance with the stress control and anchoring requirements as detailed in MTM Procedure MTPR 033000-08.9. Sleeper/ timber spacing to be adjusted so that the join is located centrally between sleepers clear of sleepers and anchored in accordance with section 9 of MTM Procedure MTPR 033000-07.10. The Westray joints shall be regularly inspected for:• Joint insulation material lost, visible cracking or disintegration• Failure of insulation in joint, particularly between the end post and the first bolt hole and beyond• Rail end damage which may cause cracking an flow across join which ultimately will bridge the joint causing a signal fault• Excessive rail head wear which may cause cracking and flow across joint which ultimately will bridge the joint causing a signal fault• Excessive rail head wear which may cause cracking• Loose, bent or broken bolt resulting in joint pulling apart or closing up• Cracked or broken fishplates• Pumping sleeper/timbers which will give little support to the joint• Ineffective ties or fastenings• Excessive or deficient ballast; excessive ballast heaped around the joint provides potential for short circuiting of the insulation. Deficient ballast will not give enough support to the joint• Ineffective drainage; moisture could cause electrical bridging of joint• Metal conductors/ heat flow across the joint which could short circuit the insulation

00207 1 Urbanise IoT Sensors and Gateway

Remote monitoring of building assets, assets movement, environmental conditions andto improve the maintenance and operation of buildings. The Remote Monitoring Platform provides the ability for an end user customer to view the data represented as trends or alarms and conditions of the buildingassets.

OCS Engineering Approval Approved 03/30/2017

- Wireless M2M Gateway - UBG-4-3C3I-SC-B1-ND- Meter Counter - UBS-4-W1-DC-PC-03-MC- Flood Sensor - UBS-4-W1-WS-03-00- Light Sensor - UBS-4-W1-LS-ST-00- On/Off Sensor - UBS-4-W1-CF-03-00- Vibration Sensor - UBS-4-W1-AC-VB-P2-00- Temperature Sensor - UBS-4-W1-TS-LD-00- Motion Sensor - UBS-4-W1-MS-ST-00- Humidity Sensor - UBS-4-HU-RH-03-00

N/A N/A Urbanise

Housing: Manufactured

in ChinaFinal

assembly: USA

Three parallel activities are proposed:1. Conduct a two month trial (expires 02/06/2017) of the Urbanise IoT system at Surrey Hills Railway No type approval for wider use on the network is granted.2. System elements shall not to be installed in vicinity of CSEE track circuits without further testing.3. The vendor shall liaise with MTM (OCS Engineering) to determine if system can meet key type approval acceptance criteria, namely:• Use of industry standard protocols and architecture.• Implementation of acceptable cybersecurity measures and compliance.• Compatibility with MTM higher level supervisory systems. • Data transfer to MTM higher level supervisory systems. • Defined system configuration roles and responsibilities.Should the vendor meet the key criteria for OCS Engineering approval, a secondary trial may be necessary to test system changes. Type approval for wider network use to be granted upon sign off from OCS Engineering.

00208 1Remote Isolation System – SBE 1500V

4000A Disconnector and Earthing Switch

The application of this equipment is to conduct isolation and short circuiting of the 1500V DC Overhead Network. Electrical Systems Provisional Type

Approval Approved 15/06/2017 14/06/2018 SBE 1500V 4000A Disconnector and Earthing Switch N/A N/A SDCEM France

• Switch shall be used in conjunction with all type approved equipment as part of the Remote Isolation System in conformance with L1-CHE-SPE-128.• Satisfactory detailed design package (shop drawings) shall be approved by MTM Engineering.• Standard drawings for product shall be produced in PTV compliant format and booked into DMS.• The switch performance shall be monitored during the trial. Positive isolation and earthing of the switch is to be monitored by indications sent to Electrol by SCADA.• MTM maintenance and operating documentation shall be produced prior to commissioning.

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

00209 1 Infraco Systems The application of this equipment is limited to the operation of the Remote Isolation System. There are no other applications for this equipment outside of switching activities. Electrical Systems Full Type Approval Approved 6/06/2017 MR41E Motor Drive N/A N/A France

To be used in conjunction with all type approved equipment as part of the Remote Isolation System in conformance with L1-CHE-SPE-128.

Satisfactory detailed design package (shop drawings) to be approved by MTM Engineering.

Standard drawings for product to be produced in PTV compliant format and booked into DMS.

The motor drive cabinet construction shall be reviewed and accessed during the trail. If the design is unacceptable, the control cabinet shall be constructed of SS316 and the thickness shall be 1.6mm according to MTM Specification L1-CHE-SPE-128.

MTM maintenance and operating documentation to be produced prior to commissioning.

00210 1 Star Quad CableFor use in the Signalling and also Communications sections of Metro Trains Melbourne-MTM for applications such as ; train detection systems cabling (axle counters, CSEE jointless track circuits, etc), signal post telephones, and similar such applications

Signals Full Type Approval Approved 1/05/2017 0.90mm 2 pair quad communications cable N/A N/A Germany There are no conditions to the Type Approval of this cable

00211 1 Traction Return Bonding Cable

For use in the Train traction return system of the MTM Melbourne network, as traction return cabling for the 1500 volts DC return. It is used as cabling connected to; impedance bonds, negative return pillars and connected to substation negative traction return, as temporary jumper cables in rail replacement activities and to jumper out insulated rail joints for specific applications

Signals Full Type Approval Approved 1/05/2017 300mm2 Aluminium N/A N/A South KoreaThat the cable be supplied in accordance to VRIOGS specifications with the only exceptions being:1) that the type insulation produced and used be HD-90-CPE2) And that the cable be supplied on 500 meter drums rather than the 250 meter drums specified in VRIOGS 012.6.34

00213 1 EWSMany existing applications include but not limited to: Hospitals, High rise buildings, University complexes, Casinos, Road Tunnels, Commercial buildings, shopping centres, and defence facilities

Structures Full Type Approval Approved 8/08/2017 N/A N/A Tyco Fire Protection New Zealand

1. Provision of spare components, materials and special tools shall be agreed with MTM Infrastructure on a case by case basis. 2. Requirements for maintenance given in manufacturer’s O&M documentation shall be incorporated into MTM maintenance procedures. 3. As per the ActivFire certificate of conformity (afp-1423):i. The WIDG2004 adaptor board where fitted shall carry the Renesas M16C62 microcontroller as the replacement for the Texas Instruments TMS77C82 microcontrollerii. Where the Vigilant FP0938 WIP handset is installed inside the emergency waning & intercommunication system panel, the Sound Pressure Level is required to exceed 80 dB(A) at a distance of one metre. 4. When installed in underground railway stations the QE90 panel shall be either:i. Installed in an IP65 rated enclosure with toughened glass facia panel; orii. Installed within space/room that is protected by a sprinkler system complying with AS2118.1; or,iii. Installed within an enclosure that provides not less than 30 minutes of fire resisting separation (ie -/30/30) from the surrounding station; or,iv. Installed within an enclosure that is constructed from a ‘fire protective covering’ as defined by NCC (BCA) provisions; or, v. Installed within a Fire Control Room as defined under NCC (BCA) Specification E1.8 Clause 6.

00214 1 Witt & Sohn Reversible Axials (MR Series)

Reversible axial fan complete with special corrosion resistant cast aluminium with inner steel skeleton impeller blade design suited for high temperature and heavy industrial applications. Independently laboratory certified for temperature rating upto 400degC/2 hours.

Structures Full Type Approval Approved 8/08/2017 Witt & Sohn Reversible Axials (MR Series) N/A N/A Witt & Sohn Germany

A-MR x / x / x / x /x On the conditions that:1. A (as in A-MR) is an adapted fan designed for high temperature applications, specifically 400°C for 2 hours. 2. Motors shall be WEG.3. Materials of construction shall be:i. Impeller: cast Al alloy c/w steel reinforced skeleton (M-SAS’) hubii. Casing: hot dipped galvanised4. Provision of spare components, materials and special tools shall be agreed with MTM Infrastructure on a case by case basis5. Requirements for maintenance given in manufacturers O&M documentation shall be incorporated into MTM maintenance procedures

00215 1 Programmable Logic Controller

High-end process control (e.g. power generation, utilities), machine control and critical infrastructure applications (e.g. tunnels, data centres, hospitals), where high availability (>99.99%) is required. Can also be used for safety applications up to SIL 3 (TUV certified product to IEC61508)

Structures Full Type Approval Approved 20/07/2017 N/A N/A Siemens Germany Projects installing the S7-400 PLC will ensure that the devices are integrated into existing maintenance arrangements and sufficient schedule 4 budget allocated for their lifecycle.

00216 2 Dampers

Tunnel Ventilation systems with considerable global application experience. Used in Australia on Cross City Tunnel, Sydney, M5 Road Tunnel, Sydney, Metro Rail, Perth, Lane Cove Tunnel, Sydney, Melbourne East Link Tunnel, Parrametta Rail Link, Sydney, Inner Northern Busway, Brisbane, Legacy Way Tunnel, Brisbane, City Link Tunnel, Melbourne.

Structures Full Type Approval Approved 23/08/2017

JFM / E / FL2 / x / x / x / x / x / x / x / x / Z04JFM / E2 / FL2 / x / x / x / x / x / x / x / x / Z04JFM / E / FL2 / x / x / x / x / x / x / x / x / Z03

JFM / E2 / FL2 / x / x / x / x / x / x / x / x / Z03

N/A N/A TROX Malaysia

Electrically Actuated JFM Dampers (‘Z04’)It is recommended that type approval is issued for TROX “JFM series” tunnel ventilation dampers of the following part number designations (note: x = no specific requirement): JFM / E / FL2 / x / x / x / x / x / x / x / x / Z04Electro-Hydraulically Actuated JFM Dampers (‘Z03’)It is recommended that type approval is also issued for TROX “JFM series” tunnel ventilation dampers of the following part number designations (note: x = no specific requirement): JFM / E / FL2 / x / x / x / x / x / x / x / x / Z03JFM / E2 / FL2 / x / x / x / x / x / x / x / x / Z03On the conditions that:1. Damper blades shall be orientated in an opposed blade arrangement. 2. Test evidence is supplied to MTM for review and approval to demonstrate that when either a thermal jacket or thermal enclosure is used to provide thermal protection to the Z03 actuator, the damper is capable of operating at 400°C for not less than 2 hours. And:i. The test report (referred to (2) above) shall contain a sufficiently detailed description of the thermal jacket or thermal enclosures used in the test to enable the tested material/assembly to be uniquely identified and readily distinguished from any similar product.ii. Only thermal jackets or thermal enclosures matching the description of the tested product (in the test referred to in item (2) above) are used.3. Provision of spare components, materials and special tools shall be agreed with MTM Infrastructure on a case by case basis. 4. Requirements for maintenance given in manufacturer’s O&M documentation shall be incorporated into MTM maintenance procedures.

JFM / E2 / FL2 / x / x / x / x / x / x / x / x / Z04On the conditions that:1. Damper blades shall be orientated in an opposed blade arrangement. 2. Actuators shall be installed within thermal enclosure boxes fabricated from 1.2 mm thick (cover and back panel) and 3.0 mm thick (mounting plate and base) galvanised sheet steel and lined with three layers of Promat ‘Promatect H’ boards of thicknesses 20 mm, 20 mm, and 40 mm respectively. Protection of damper actuators by thermal blankets, in lieu of this Promatect H thermal enclosure, can be used if:i. Test evidence is supplied to MTM for review and approval to demonstrate that the thermal blanket is capable of ensuring that the JFM damper is capable of operating at 400°C for not less than 2 hours. ii. This test report (referred to (i) above) contains a sufficiently detailed description of the thermal jacket used in the test that allows the tested thermal jacket material/assembly to be uniquely identified and readily distinguished from any other similar product.iii. Only thermal jackets matching the description of the tested product (in the test referred to in item (i) above) are used. 3. Provision of spare components, materials and special tools shall be agreed with MTM Infrastructure on a case by case basis. 4. Requirements for maintenance given in manufacturer’s O&M documentation shall be incorporated into MTM maintenance procedures.

00218 1161mm2 Contact Wire181mm² Catenary Wire9.6mm² Dropper Wire

For use on the 1500V overhead traction wiring system. Structures Full Type Approval Approved 5/06/2017161mm2 Contact Wire181mm² Catenary Wire9.6mm² Dropper Wire

N/A N/A NKT Cables Germany • There shall be no joints in the contact or catenary wires. This includes joints being made in the raw material prior to drawing.• Country of manufacturer to remain in Germany.

00219 1 Remote Isolation System: CRS2000 Voltage Sensor

The application of this equipment is limited to the operation of the Remote Isolation System. There are no other applications for this equipment outside of switching activities. Electrical Systems Provisional Type

Approval Approved 29/06/2017 CRS2000+CBI21CA-24VDC PROAT Spain

The unit shall be used in conjunction with all type approved equipment as part of the Remote Isolation System in conformance with L1-CHE-SPE-128.

Satisfactory detailed design package (shop drawings) shall be approved by MTM Engineering.

Standard drawings for product shall be produced in PTV compliant format and booked into DMS.

MTM maintenance and operating documentation shall be produced prior to commissioning.

On the completion of the trial, a test report shall be produced with the following criteria as a minimum:• An inspection of the connections to the end of the of the Proat voltage transducer• Visual inspection of the bushings/unit for burn marks.• Confirmation of the correct operation levels of the remote isolation system as a whole and of the Proat voltage transducer

00221 1 Texlon ETFE Roofing System Roof Skylight Structures Engineering Approval Approved 23/06/2017 LK-700 Vector Foiltec Germany &

China

Vector Foiltec is to provide an Operation and Maintenance Manual for the Texlon ETFE roofing system. The Manual must detail equivalent products that are freely available from alternative suppliers for all components. It shall also include work instructions for repairs to the system.

Vector Foiltec shall provide a 25 year material and system warranty. The warranty will state that Vector Foiltec will continue to warrant the system following repairs, provided these are carried out by a qualified repairer following the work instructions and using equivalent products detailed in the Operation and Maintenance Manual. The warranty may note that repairs are to be warranted by the repairing contractor.

The ETFE pillows shall be designed to support the accumulation of water in a collapsed state.

The air supply system shall be provided with backup power designed to operate for a minimum of eight hours to minimise the likelihood of failure.

The proposed installation shall demonstrate enhanced safety outcomes such as improved ventilation of smoke in a significant fire event, improved lighting conditions to assist in the safe departure of trains, or similar.

Texlon ETFE does not meet the requirements of MTM DPN L1-CHE-INS-025. A Fire Engineering Report shall be provided to support a conclusion that the material does not present a risk in the application and location proposed by the design. An independent third party assessment shall be provided to support a conclusion that appropriate fire testing data has been presented and that it is comparable to the application and location proposed by the design.

00222 1 Multi-Point Aspirating Smoke Detection System (MASDS)

Data Centres, Sub-stations, Concourse and Platforms, Service Tunnels and Train CarriagesVESDA within Metro or Rail applications is synonymous to protection of critical assets and enabling safe evacuation of people in the event of a fire.

Structures Full Type Approval Approved 8/08/2017 VESDA-E VEU Xtralis Malaysia

• The VESDA-E VEU series aspirated detector shall be supplied with an aluminium enclosure.• Provision of spare components, materials and special tools shall be agreed with MTM infrastructure on a case by case basis.• Requirements for maintenance given in manufacturer’s O & M documentation shall be incorporated into MTM maintenance procedures.

00223 1 SIMATIC HMI ComfortSIMATIC HMI devices offer the option of local operation of ventilators or other system components Structures Full Type Approval Approved 20/07/2017 TP1500 Windows CE

V6.0 Siemens Germany

1. Implementation of security recommendations in accordance with Siemens document “Security guidelines for SIMATIC HMI devices”, particularly: 1.1 Panel access protection A password shall be implemented to protect access to the panel device settings (section 1.3.1). 1.2. User administration function A user administration function shall be implemented that governs each panel operation via authorisation (section 1.3.2).2. Software updates The HMI shall be incorporated as part of a defined maintenance process that ensures software is kept up to date.3. Software resiliency The HMI shall be installed with the SIMATIC HMI memory card option to facilitate field replacement without reprogramming.4. Procurement HMI to be ordered with Siemens screen membrane option.

00224 1 SCALANCE Industrial Ethernet switches Industrial Ethernet switched for networks at data transfer rates of 10/100/(1000) Mbps in a line, star or ring topology. Structures Full Type Approval Approved 20/07/2017 6GK5206-2BS00-2AC2 1 1 Siemens Germany

1.Purchasing: Scalance switches shall be procured with C-PLUG dongles.2. Deployment: 2.1 FMP shall be configured when using fibre SFPs. 2.2 Fault mask shall be configured to indicate power or link abnormality. 2.3 SNMP shall be configured as read only. 2.4 Ingress filtering shall be used for port based VLANs. 2.5 In a CCTV environment, unknown multicast shall be blocked on the Fast Ethernet ports.

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

00225 1 TMC 3.3kV/2.2kV/110V Single Phase Signal Load Transformers

Supply of 110V signalling loads from the 3.3kV, or alternatively the 2.2kV, Essential Services Distribution SystemTMC 3.3kV/2.2kV/110V Single Phase Signal Load Transformers

Electrical Systems Provisional Type Approval Approved 7/06/2017 6/06/2018

TMT120033322C (3kVA) TMT120063322C (6kVA) TMT120103322C (10kVA)

TMT120153322C (15kVA) TMT120203322C (20kVA)

NA NA Transformers Manufacturing Company (TMC) Australia

To be used in conjunction with a Trackside Essential Services Switchgear Assembly conforming to MESP 041000-01

Satisfactory completion of Type Testing and Routine Testing on a unit (any variant listed) to AS 60076.11 including sound level and temperature rise testing.

Maintenance instructions and service schedules to be produced to include recommended servicing activities

Routine tests to AS 60076.11 to be completed on each unit.

00228 1 22kV Fuse Isolator 11kV or 22kV exposed bus fuse isolator for use within substations Electrical Networks Grandfather Rights Approved 15/04/2017 V Series EDOModel V150PC6S0000 ABB Selection of fuse with appropriate rating to be undertaken by competent engineer and approved prior to installation

Prospective fault level not to exceed 6kA

00229 1 22kV Fuse Isolator 11kV or 22kV exposed bus fuse isolator for use within substations Electrical Networks Grandfather Rights Approved 15/04/2017Single Phase Hookstick Operation 12/24kV, 150kV

BILPart Number 72298/17MT2

NGK Stanger Selection of fuse with appropriate rating to be undertaken by competent engineer and approved prior to installationProspective fault level not to exceed 6kA

00230 1 22kV Isolator11kV or 22kV exposed bus isolator for use within substations

Electrical Networks Grandfather Rights Approved 15/04/2017Single Phase Hookstick Operation. 12/24KV, 630A

HVIPart Number 70423-3MT

NGK Stanger

00231 1 22kV Surge Diverter - ABB Polim D Surge Diverter for use on 22kV outdoor buses at substations Electrical Networks Grandfather Rights Approved 15/04/2017 POLIM-D26, 32.5kV rmsABB Part: 7840064 ABB Engineering review of insulation coordination required.

00232 1 22kV/1000V TMC Dry Signal Transformer (50kVA/63kVA) Signal Transformer Electrical Networks Grandfather Rights Approved 15/04/2017 TMC Melbourne Shop drawing approval by MTM Engineering required prior to manufacture

00233 1 22kV/2200V Etel Oil Signal Transformer (50kVA) Signal Transformer Electrical Networks Grandfather Rights Approved 15/04/2017 Etel New Zealand Shop drawing approval by MTM Engineering required prior to manufacture

00234 1 22kV/2200V TMC Dry Signal Transformer (50kVA/63kVA) Signal Transformer Electrical Networks Grandfather Rights Approved 15/04/2017 TMC Melbourne Shop drawing approval by MTM Engineering required prior to manufacture

00235 1 22kV/230V Etel Oil Auxiliary Transformer (50kVA) Substation Auxiliary Transformer - Supply of Substation Lighting and Power Only Electrical Networks Grandfather Rights Approved 15/04/2017 Etel New Zealand Shop drawing approval by MTM Engineering required prior to manufacture

00236 1 22kV/230V TMC Dry Auxiliary Transformer (50kVA) Substation Auxiliary Transformer - Supply of Substation Lighting and Power Only Electrical Networks Grandfather Rights Approved 15/04/2017 TMC Melbourne Shop drawing approval by MTM Engineering required prior to manufacture

00237 1 22kV/415V Etel Oil Auxiliary Transformer (50kVA) Substation Auxiliary Transformer - Supply of Substation Lighting and Power Only Electrical Networks Grandfather Rights Approved 15/04/2017 Etel New Zealand Shop drawing approval by MTM Engineering required prior to manufacture

00238 1 22kV/415V TMC Dry Auxiliary Transformer (50kVA) Substation Auxiliary Transformer - Supply of Substation Lighting and Power Only Electrical Networks Grandfather Rights Approved 15/04/2017 TMC Melbourne Shop drawing approval by MTM Engineering required prior to manufacture

00239 1 3220kVA TMC Dry Rectifier Transformer Rectifier Transformer for use with 1500V 3MW Class VI Rectifier Electrical Networks Grandfather Rights Approved 15/04/2017 TMC Melbourne Shop drawing approval by MTM Engineering required prior to manufacture

00240 1 3MW UGL Rectifier with integrated Rectifier Control System 1500V 3MW Class VI Rectifier Electrical Networks Grandfather Rights Approved 15/04/2017 UGL Sydney Shop drawing approval by MTM Engineering required prior to manufacture

00241 1

95mm2 Copper Conductor, XLPE Insulated, Screened, PVC/HDPE

Sheathed 12.7/22(24)kV Single Core Cable

22kV Cabling within substations Electrical Networks Grandfather Rights Approved 15/04/2017 Olex

00242 1

95mm2 Copper Conductor, XLPE Insulated, Screened, PVC/HDPE

Sheathed 12.7/22(24)kV Single Core Cable

22kV Cabling within substations Electrical Networks Grandfather Rights Approved 15/04/2017 Prysmian

00243 1

95mm2 Copper Conductor, XLPE Insulated, Screened, PVC/HDPE

Sheathed 12.7/22(24)kV Single Core Cable

22kV Cabling within substations Electrical Networks Grandfather Rights Approved 15/04/2017 General Cable

00244 1

185mm2 Aluminium Conductor, XLPE Insulated, Screened, PVC/HDPE

Sheathed 12.7/22(24)kV Three Core Cable

22kV Cabling Electrical Networks Grandfather Rights Approved 15/04/2017 Olex

00245 1

185mm2 Aluminium Conductor, XLPE Insulated, Screened, PVC/HDPE

Sheathed 12.7/22(24)kV Three Core Cable

22kV Cabling Electrical Networks Grandfather Rights Approved 15/04/2017 Prysmian

00246 1

185mm2 Aluminium Conductor, XLPE Insulated, Screened, PVC/HDPE

Sheathed 12.7/22(24)kV Three Core Cable

22kV Cabling Electrical Networks Grandfather Rights Approved 15/04/2017 General Cable

00247 1 400mm2 Aluminium Screened 1.9/3.3kV Single Core Cable 1500V DC connections within substations and to switch masts Electrical Networks Grandfather Rights Approved 15/04/2017 Olex

00248 1 400mm2 Aluminium Screened 1.9/3.3kV Single Core Cable 1500V DC connections within substations and to switch masts Electrical Networks Grandfather Rights Approved 15/04/2017 Prysmian

00249 1 400mm2 Aluminium Screened 1.9/3.3kV Single Core Cable 1500V DC connections within substations and to switch masts Electrical Networks Grandfather Rights Approved 15/04/2017 General Cable

00250 1 400mm2 Aluminium Unscreened 1.9/3.3kV Single Core Cable 1500V Negative Connections within substations and to negative pillars Electrical Networks Grandfather Rights Approved 15/04/2017 Olex

00251 1 400mm2 Aluminium Unscreened 1.9/3.3kV Single Core Cable 1500V Negative Connections within substations and to negative pillars Electrical Networks Grandfather Rights Approved 15/04/2017 Prysmian

00252 1 400mm2 Aluminium Unscreened 1.9/3.3kV Single Core Cable 1500V Negative Connections within substations and to negative pillars Electrical Networks Grandfather Rights Approved 15/04/2017 General Cable

00253 1 500mm2 Aluminium Screened 1.9/3.3kV Single Core Cable 1500V DC connections within substations and to switch masts Electrical Networks Grandfather Rights Approved 15/04/2017 Olex

00254 1 500mm2 Aluminium Screened 1.9/3.3kV Single Core Cable 1500V DC connections within substations and to switch masts Electrical Networks Grandfather Rights Approved 15/04/2017 Prysmian

00255 1 500mm2 Aluminium Screened 1.9/3.3kV Single Core Cable 1500V DC connections within substations and to switch masts Electrical Networks Grandfather Rights Approved 15/04/2017 General Cable

00256 1 500mm2 Aluminium Unscreened 1.9/3.3kV Single Core Cable 1500V Negative Connections within substations and to negative pillars Electrical Networks Grandfather Rights Approved 15/04/2017 Olex

00257 1 500mm2 Aluminium Unscreened 1.9/3.3kV Single Core Cable 1500V Negative Connections within substations and to negative pillars Electrical Networks Grandfather Rights Approved 15/04/2017 Prysmian

00258 1 500mm2 Aluminium Unscreened 1.9/3.3kV Single Core Cable 1500V Negative Connections within substations and to negative pillars Electrical Networks Grandfather Rights Approved 15/04/2017 General Cable

00259 1 ABB R-MAG 27kV Outdoor ACCB Outdoor 22kV ACCB, Outdoor 11kV ACCB Electrical Networks Grandfather Rights Approved 15/04/2017 ABBFort Mary Florida, Mexico

Shop drawing approval by MTM Engineering required prior to manufacture

00260 1 ABB VD4 24kV Indoor AC Switchgear Assembly Indoor 22kV Switchgear, Indoor 11kV Switchgear Electrical Networks Grandfather Rights Approved 15/04/2017 ABB Shop drawing approval by MTM Engineering required prior to manufacture

00261 1 Balfour Beatty DCP106 Protection Relay DC Protection relay. Electrical Networks Grandfather Rights Approved 15/04/2017 Balfour Beatty To be used with UGL KDA DCCBs, or in other designs as approved by MTM Engineering.

00262 1 Century Yuasa 110V 3kW Battery Charger Substation 110V control battery charger Electrical Networks Grandfather Rights Approved 15/04/2017 Century Yuasa Shop drawing approval by MTM Engineering required prior to manufacture

00263 1 Century Yuasa 125V 3kW Battery Charger Substation 125V control battery charger Electrical Networks Grandfather Rights Approved 15/04/2017 Century Yuasa Shop drawing approval by MTM Engineering required prior to manufacture

00264 1 Century Yuasa 48V 3kW Battery Charger Substation 50V control battery charger Electrical Networks Full Type Approval Approved 15/04/2017 Century Yuasa Shop drawing approval by MTM Engineering required prior to manufacture

00265 1 Century Yuasa Battery 6V Cell Substation control battery Electrical Networks Grandfather Rights Approved 15/04/2017 UXH125-6 Century Yuasa Preferred battery for use within Substations due to standardisation.

00266 1 DCCB Bus-Tie W&B Enclosed Bus-Tie DCCB Electrical Networks Grandfather Rights Approved 15/04/2017 Whipp & Bourne Great Britain Suitable for use in existing Whipp & Bourne installations only

00267 1 DCCB Feeder JR12 Exposed Feeder DCCB Electrical Networks Grandfather Rights Approved 15/04/2017 Various Suitable for renewals only

00268 1 DCCB Feeder W&B Enclosed Feeder DCCB Electrical Networks Grandfather Rights Approved 15/04/2017 Whipp & Bourne Great Britain Suitable for use in existing Whipp & Bourne installations only

00269 1 DCCB Rectifier JR12 Exposed Rectifier DCCB Electrical Networks Grandfather Rights Approved 15/04/2017 Various Suitable for renewals only

00270 1 DCCB Rectifier W&B Enclosed Rectifier DCCB Electrical Networks Grandfather Rights Approved 15/04/2017 Whipp & Bourne Great Britain Suitable for use in existing Whipp & Bourne installations only

00271 1 KDA Bus-Tie DCCB Enclosed 4000A 125V Control (Cable or Busbar type) Bus-Tie DCCB Electrical Networks Grandfather Rights Approved 15/04/2017 UGL France/Sydne

y Shop drawing approval by MTM Engineering required prior to manufacture

00272 1 KDA Bus-Tie DCCB Enclosed 4000A 48V Control (Cable or Busbar type) Bus-Tie DCCB Electrical Networks Grandfather Rights Approved 15/04/2017 UGL France/Sydne

y Shop drawing approval by MTM Engineering required prior to manufacture

00273 1 KDA Bus-Tie Isolator Enclosed 4000A 125V Control (Cable or Busbar type) Bus Tie DC Isolator Electrical Networks Grandfather Rights Approved 15/04/2017 UGL France/Sydne

y Shop drawing approval by MTM Engineering required prior to manufacture

00274 1 KDA Bus-Tie Isolator Enclosed 4000A 48V Control (Cable or Busbar type) Bus-Tie DC Isolator Electrical Networks Grandfather Rights Approved 15/04/2017 UGL France/Sydne

y Shop drawing approval by MTM Engineering required prior to manufacture

00275 1 KDA Feeder DCCB Enclosed 2000A 125V Control Feeder DCCB Electrical Networks Grandfather Rights Approved 15/04/2017 UGL France/Sydne

y Shop drawing approval by MTM Engineering required prior to manufacture

00276 1 KDA Feeder DCCB Enclosed 2000A 48V Control Feeder DCCB Electrical Networks Grandfather Rights Approved 15/04/2017 UGL France/Sydne

y Shop drawing approval by MTM Engineering required prior to manufacture

00277 1 KDA Master Feeder DCCB Enclosed 2000A 125V Control Feeder DCCB Electrical Networks Grandfather Rights Approved 15/04/2017 UGL France/Sydne

y Shop drawing approval by MTM Engineering required prior to manufacture

00278 1 KDA Master Feeder DCCB Enclosed 2000A 48V Control Feeder DCCB Electrical Networks Grandfather Rights Approved 15/04/2017 UGL France/Sydne

y Shop drawing approval by MTM Engineering required prior to manufacture

00279 1 KDA Rectifier DCCB Enclosed 4000A 125V Control Rectifier DCCB Electrical Networks Grandfather Rights Approved 15/04/2017 UGL France/Sydne

y Shop drawing approval by MTM Engineering required prior to manufacture

00280 1 KDA Rectifier DCCB Enclosed 4000A 48V Control Rectifier DCCB Electrical Networks Grandfather Rights Approved 15/04/2017 UGL France/Sydne

y Shop drawing approval by MTM Engineering required prior to manufacture

00281 1 KDA - Whipp & Bourne Transition Cubicle Bus connections between KDA and Whipp & Bourne DC Buses Electrical Networks Grandfather Rights Approved 15/04/2017 UGL Sydney Shop drawing approval by MTM Engineering required prior to manufacture

00282 1 Micom P120 Protection Relay Single Phase AC protection relay for use on earth fault protection and 650V/2.2kV systems Electrical Networks Grandfather Rights Approved 15/04/2017 Areva, Alstom or Schneider

00283 1 Micom P122 Protection Relay AC Protection Relay for use on 1kV/6.6kV/11kV/22kV systems Electrical Networks Grandfather Rights Approved 15/04/2017 Areva, Alstom or Schneider

00284 1 Micom P123 Protection Relay AC Protection Relay for use on 1kV/6.6kV/11kV/22kV systems Electrical Networks Grandfather Rights Approved 15/04/2017 Areva, Alstom or Schneider

00285 1 Micom P127 Protection Relay AC Protection Relay for use on 11kV/22kV systems Electrical Networks Grandfather Rights Approved 15/04/2017 Areva, Alstom or Schneider

00286 1 PSG/LAI VD4 Indoor AC Switchgear Assembly Indoor 22kV Switchgear, Indoor 11kV Switchgear Electrical Networks Grandfather Rights Approved 15/04/2017 PSG or LAI Shop drawing approval by MTM Engineering required prior to manufacture

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

00287 1 Station Post Insulator 22kV Buswork Insulation for outdoor use within substations Electrical Networks Grandfather Rights Approved 15/04/2017 SPI340-12-12-RB EMC Pacific

00288 1 Acrylic Screen Use for the viaduct screens on the south side in all areas on LXRP -CTD. Structures Full Type Approval Withdrawn IHO184RD004BZVY PALRAM Israel

00289 14 pairs 1.5 mm2 (7/0.5 mm) Plain Annealed Copper, 0.6/1 kV XLPE

Insulated

4 pairs 1.5 mm2 (7/0.5 mm) Plain Annealed Copper, 0.6/1 kV XLPE Insulated (0.7 mm min av wall), Laid up, HFS-90-TP Bedded (2.0 mm nom wall), Copper taped, HFS-110-TP Sheathed (3.0 mm min av wall), Fire Safe cable generally to AS/NZS 5000.1 and generally to VRIOGS Standard 012.6.37.

Local cable connection between the Signal Mast Junction box and signal head.

Signals Full Type Approval Approved 22/08/2017 IHO184RD004BZVY Nexans Olex Australia/New Zealand This cable shall not be used in the MURL or similar type tunnel applications

00290 14 pair 1.5 mm2 (7/0.5 mm) Plain

Annealed Copper, 0.6/1 kV XLPE Insulated

Local cable connection between the Signal Mast Junction box and signal head. Signals Full Type Approval Approved 22/08/2017 CU/X90/HFS110/OSCR/HFS110 4X2X1.5 Prysmian China This cable shall not be used in the MURL or similar type tunnel applications

00291 13 pairs 1.5 mm2 (7/0.5 mm) Plain Annealed Copper, 0.6/1 kV XLPE

Insulated

Three pairs 1.5 mm2 (7/0.5 mm) Plain Annealed Copper, 0.6/1 kV XLPE Insulated (0.7 mm min av wall), Laid up, HFS-90-TP Bedded (2.0 mm nom wall), Copper taped, HFS-110-TP Sheathed (3.0 mm min av wall), Fire Safe Cable generally to AS/NZS 5000.1 and generally to VRIOGS Standard 012.6.37

Local cable connection between the Signal Mast Junction box and signal head.

Signals Full Type Approval Approved 22/08/2017 IHO184RD003BZVY Nexans Olex Australia/New Zealand This cable shall not be used in the MURL or similar type tunnel applications

00292 13 pairs 1.5 mm2 (7/0.5 mm) Plain Annealed Copper, 0.6/1 kV XLPE

InsulatedLocal cable connection between the Signal Mast Junction box and signal head. Signals Full Type Approval Approved 22/08/2017 CU/X90/HFS110/OSCR/HFS110 3X2X1.5 Prysmian China This cable shall not be used in the MURL or similar type tunnel applications

00294 1 Siemens Derail and Crowder MK11 The derail is used for the protection against run away vehicles, with the crowder component being used to prevent the derailed vehicle from then becoming “re-railed” Signals Full Type Approval Approved 24/08/2017 Siemens Derail and Crowder MK11

Switchguard D150 derail MK11,and

crowder MK11

Siemens Australia

That the following Conditions shall be met;1. Only the following listed part numbers shall to be purchased and used within MTM Network areas, a. Left Hand Installation Requirement-Derail D150 and Crowder C150, 1600mm gauge, Part number 3330100502 b. Right Hand Installation Requirement-Derail D150 and Crowder C150, 1600 mm gauge, Part Number 3330100501 2. Selection of derailer only or derailer/crowder combinations shall be based on operational performance requirements and nominated performance limits.3. D150 derailer shall only be used where maximum speed of rolling stock does not exceed 15kph.4. D150 and C150 derailer/crowder combination shall only be used where maximum speed of rolling stock does not exceed 25kph.5. Operation of Derail and Crowder shall only be used with lever operation or point motor operation. Manual operation shall not be permitted.6. Derailer and Crowder shall be securely locked in either the normal position or reverse position at all times (The units shall not be free to move when unattended).7. Units shall be installed by competent installers in accordance with manual TTTODER Issue 10.0 or later.8. The derailer shall be installed on the outside rail when the track is curved.9. For concrete sleeper installations use Siemens pre-drilled sleepers. Timber sleepers may be used if in an acceptable condition to MTM.10. Each installation shall consider risks that may occur post derailments, run off areas (example, ballast drag) should be provided where ever space is available.

00295 2 Syfonic Drainage System Syfonic Roof Drainage is an efficient alternative to draining storm water from roof areas compared with conventional systems which have been used traditionally. Structures Engineering

Approval Approved 16/10/2017 SS01 G Syfon Systems Australia

The Syfonic Roof Drainage System was initially accepted for use at Carnegie, Murrumbeena, Hughesdale, Clayton and Noble Park Stations only. This revised approval aims to extend the approval to other sites. The design and installation of the system will take into consideration maintainability (e.g. service life, non-proprietary components, removal of blockages), specific design (e.g. pipe run lengths, number of bends, access to undertake repairs) and suitability based on location (e.g. potential for obstruction due to leaf litter).

-An Operation and Maintenance Manual for the roof drainage system is to be provided. The Manual must detail equivalent products that are freely available from alternative suppliers for all components including pipework, bracketry, inlets, debris guards and first flush valves. It must also include work instructions for repairs to the system and DMS compliant drawings that describe the system.-The preferred supplier for the inlet valve (SS01) is Syfon Systems, 22 Hargreaves St, Huntingdale, Victoria, 3166.However similar or equal designs shall also be considered based on evidence of satisfactory performance such as good project references.-The design life of the product is to be as per Australian Standards.-The warranty is to state that the supplier/manufacturer will continue to warrant the system following repairs, provided these are carried out by a qualified plumber following the work instructions detailed in the Operation and Maintenance Manual. The warranty will note that repairs are to be warranted by the repairing contractor.-Overflow protection is to be provided using a conventional (non-siphonic) system.-The pipes must be accessible to ensure blockages can be removed if needed.-If frequent OR biannual maintenance inspections are required, engineering controls such as handrails for fall protection shall be installed to enable access without a safety harness.-Noise levels during operation of the system shall not have a significant adverse effect on PA audibility. An acoustic assessment to demonstrate that the system will not cause adverse impacts to noise sensitive receivers including staff and customers on the platform and nearby residents is to be provided. -Leaf/debris guards to be installed at the inlets to minimise the likelihood of blockages in the gutters impeding the performance of the system. In bushfire prone areas, the design and construction of the system shall comply with AS 3959 – 2009 Construction of buildings in bushfire prone areas.-Acoustic lagging (Soundlag 4525C or approved equivalent) to be provided to pipework in noise sensitive areas such as staff areas or station waiting rooms.-HDPE pipework to be shrouded from direct sunlight.-Purpose designed rail and bracketing system to be used to support the pipe to ensure its structural integrity and minimise vibration problems. Installation to be carried out by fully licensed and experienced plumbers trained in the requirements of siphonic roof drainage and HDPE welding techniques.

00296 1 Witt & Sohn Reversible Axials (NR Series)

Reversible axial fan complete with special corrosion resistant cast aluminium with inner steel skeleton impeller blade design suited for high temperature and heavy industrial applications. Independently laboratory certified for temperature rating upto 400degC/2 hours.

Structures Full Type Approval Withdrawn Witt & Sohn Reversible Axials (NR Series) N/A N/A Witt & Sohn Germany

00297 2 Variable speed driveThe main function of the Altivar Process / Machines products ranges is the speed control and variation of a synchronous, asynchronous or reluctance electric motor for fluid management and industrial applications.

Structures Full Type Approval Approved 23/08/2017 ATV630D45N4 - V1.3 IE15 Schneider Electric France / China

1. Shall comply with AS 61800.3 and IEC 610002. Technical Backup support shall be available 24 hours 7 days a week.3. Potential for voltage spikes and electro –magnetic interference from VSD to Vic track equipment shall have incorporated AC line reactors, Sinus filters and cables shielding.4. Design of VSD installation shall take into account power harmonic content, Voltage spikes and Electromagnetic noise 5. IP 21 rated unit shall be installed inside enclosure or switch room.6. The distance between the VSD and the motor it is controlling shall be no greater than 500 metres.Shall be designed in a n+1 arrangement if installed as part of safety-critical system

00298 2 Variable speed driveThe main function of the Altivar Process / Machines products ranges is the speed control and variation of a synchronous, asynchronous or reluctance electric motor for fluid management and industrial applications.

Structures Full Type Approval Approved 23/08/2017 ATV650D45N4 - V1.3 IE15 Schneider Electric France / China

1. Shall comply with AS 61800.3 and IEC 610002. Technical Backup support shall be available 24 hours 7 days a week.3. Potential for voltage spikes and electro –magnetic interference from VSD to Vic track equipment shall have incorporated AC line reactors, Sinus filters and cables shielding.4. Design of VSD installation shall take into account power harmonic content, Voltage spikes and Electromagnetic noise 5. Unit shall be IP55 rated.6. The distance between the VSD and the motor it is controlling shall be no greater than 500 metres.Shall be designed in a n+1 arrangement if installed as part of safety-critical system

00300 1 GageLok Rail Screws GageLok screws can be used in timber and composite sleepers. Track Provisional Type Approval Approved 7/07/2017 6/01/2018 N/A N/A Haiyan Guangda Hardware Co.

Ltd China

• A 6 month trial shall be conducted at selected sites, for each screw type, and a report provided to validate performance in the field, prior to the commencement of trial, the MoC and EC process shall be followed including the development of trials success criteria.• All dog and lock screws shall be inserted in accordance with the manufacturer’s procedures• MTM purchasing shall ensure that Cold Forge is ISO9001 accredited when purchasing GageLok Rail Screws.• MTM reserves the right to arrange an independent test of these products and audit the manufacture and supply of these components to confirm compliance to AS19011• The supplier or manufacturer shall advise MTM of any product or systems related changes made to any of the following aspect: o Identification o Performance characteristics o Form/Fit/Function o Place of manufacture o Installation/operating process.

00301 1 Lai Negative Pillar outdoor Trackside negative pillar Electrical Networks Full Type Approval Approved 1/11/2017 N/A N/A N/A LAI Switchboards Australia

00302 1 47kg Rail To be used for rail closures for RFD repair in accordance with MTPR 033000-10 – Welded Track Management Manual Chapter 10 – Closure Rails Track Grandfather Rights Approved

47kg RailN/A N/A OneSteel Whyalla Steelworks Australia

1. The first batch of 47kg rail produced is to undergo testing and OneSteel to validate compliance in accordance with AS1085.1-2002 - Railway track materials Part 1: Steel rails2. To be used for rail closures for RFD repair in accordance with MTPR 033000-10 – Welded Track Management Manual Chapter 10 – Closure Rails

00303 1 Powerjoint - termination kit Rectifier and rectifier transformer indoor and outdoor 581 V termination kits aluminium and bimetal lugs, Negative pillar outdoor aluminium termination lugs Electrical Networks Engineering

Approval Approved 30/08/2017

H6N500BLMT04H6N500BLMT05H1R500ALMT06H1R500BLMT07H1W500ALTM08H1W500BLMT09H1B500ALMT10H1B500BLMT11

N/A N/A Legend Power China For use on rectifier transformer, negative busbar and rectifier low voltage terminations only

00304 1 Series 3590 Boom Mechanism

The WCH Series 3590 Boom Mechanism operates level crossing boom arms and is used extensively in the United States, with Sydney Trains, in the ARTC Network, TasRail and with CRN.The mechanism was first installed in NSW in 1975 and there have been no changes to the design or with manufacturing since then. The mechanism has a proven record of reliability and ease of maintenance in the ARTC Network.

Signals Provisional Type Approval Approved 8/06/2017 9/09/2017 3593E N/A N/A Western-Cullen-Hayes USA

References contained within these conditions are made to “Provisional Type Approval Report WCH 3593E Boom Mechanism” version 1 dated 08/06/2017.1) The Provisional Type Approval is valid for three (3) months from the date of approval.2) The user shall ensure that he/she is fully aware of and complies with the information given in “WCH Model 10 Signals with 3590 Series Gate Mechanism – Service and installation manual” revision 11/95.3) Only the components in Appendix 1 shall be used.4) Only the tools in Appendix 1 shall be used for installation and maintenance.5) Any changes to the mechanism by WCH or Bradken shall be detailed to MTM.6) Western-Cullen-Hayes and Bradken shall retain ISO 9001 accreditation and inform MTM of any change in accreditation.7) Spare units are to be kept at critical store locations to ensure that any faults that occur can be rectified as soon as possible.8) MTM are to request that Western-Cullen-Hayes update the 3590 Series Boom Mechanism Manual to reflect any changes and the addition of the fuse panel and terminations.9) MTM are to confirm upon delivery that the models delivered are 3593E mechanisms by checking the circuit diagram on the front cover of the mechanism and confirming that the relay within is the non-vital relay.10) MTM are to follow the recommendations as per the Maintenance Alert – ISC-060 by V/Line dated 12th of April 2017.11) Fuses adjacent to the boom arm light terminations are not to be used and should be removed.12) Full Type Approval is to be conditional upon the resolution of the Power Loss Free-Falling failure mode by a permanent solution.13) Full Type Approval is to be conditional upon confirmation of the WCH 3593E Test Procedure via the test report from Infrastructure Delivery and full CDS Logger results.

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

00305 1 ShapeShell Architectural Cladding Architectural Cladding Structures Engineering Approval Approved 23/06/2017 Free Form ‘Monocoque’ N/A N/A Vector Foiltec Indonesia

Shapeshell is accepted for use as an architectural cladding material at Carnegie, Murrumbeena, Hughesdale, Clayton and Noble Park Stations only. Installation at other locations shall be subject to approval, which will take into consideration access provisions for maintenance and repairs including ability to paint over in the event of scratching using a paint roller and a standard Dulux paint colour and product, whether the placement of the product within the design is vulnerable to vandalism, and whether the colour, placement and gloss level of the product will cause signal sighting, glare or reflectivity problems for train drivers. The design life of fixings is to exceed the design life of the cladding by a minimum of 25%. Details of fixings must be included in architectural drawings for prior review and acceptance by MTM Engineering and included in the DMS compliant drawing set submitted at as-built stage.

ShapeShift shall provide an Operation and Maintenance Manual for ShapeShell cladding. The Manual shall include work instructions for repairs to the system and detail equivalent products that are freely available from alternative suppliers for all repairs. Shop drawings for moulds are to be supplied in the Operation and Maintenance manual and ShapeShift must agree to provide MTM with design IP licence/s to enable procurement from an alternative supplier in the event that ShapeShift cease to trade.

ShapeShift is to provide a 50 year warranty for the product substrate and a 25 year warranty for the surface finish including colour and gloss retention. The warranty will state that ShapeShift will continue to warrant the system following repairs, provided these are carried out by a qualified repairer following the work instructions and using equivalent products detailed in the Operation and Maintenance Manual. The warranty may note that repairs are to be warranted by the repairing contractor.

ShapeShell does not meet the requirements of MTM DPN L1-CHE-INS-025. A Fire Engineering Report shall provide to support a conclusion that the material does not present a risk in the application and location proposed by the design. An independent third party assessment shall provide to support a conclusion that appropriate fire testing data has been presented and that it is comparable to the application and location proposed by the design.

00307 1 TPWS PVC 2 core electrical cable It is a 2 core 2.5 mm2, 50/0.25 mm2 Stranding, 0.6/1kV, XLPE X-90 insulated, 5V-90 PVC sheathed, with drain wire 2.5mm², and metallic tape screen.

Signals Full Type Approval Approved 7/08/2017

2 core 2.5 mm2, 50/0.25 mm2 Stranding, 0.6/1kV, XLPE X-90 insulated, 5V-90 PVC sheathed, with drain wire 2.5mm², and metallic tape screen. TPWS use

N/A N/A Prysmian Group Australia The cable shall not be used in the MURL or similar type tunnel applications

00308 1 160kVA 11000/400V Transformer Essential Services / Auxiliary Transformer Electrical Networks Provisional Type Approval Approved 21/06/2017 TMT0516011-BD-IP43-Dzn0 N/A N/A TMC Australia

Standard drawings for product shall be produced in PTV compliant format and booked into DMS.

Prior to commissioning, Type Testing and Routine Testing on a unit to AS 60076.11 including sound level and temperature rise testing shall be undertaken to the satisfaction of MTM Engineering.

00309 1 Miniature relays TYPE BRB930 Series

These miniature relays are used in signalling and rail systems areas of MTM, for both vital and non-vital applications. Typical applications such as, signal circuits, train stop controls, track circuits, point circuits, level and pedestrian crossing circuits, signalling interlocking functionality over the entire MTM Network.

Signals Full Type Approval Approved 14/09/2017 Miniature relays TYPE BRB930 Series N/A N/A Mors Smitt.UK Ltd UK Refer to certificate

00312 1 SEL Protective RelayFor use in providing protection in MTM’s internal 22kV network. These will be located in substations within a dedicated protection cabinet. These relays require an interconnected fibre for communication purposes.

Substations Full Type Approval Approved 1/08/2017 SEL-411L / SEL-311L SEL USA

Where provided for Line Differential Protection (ANSI 87L), shall be used in conjunction with a type approved GPS clock, network switch and either dedicated fibres or other approved secure network.The relay shall be installed and used in accordance with manufacturer recommendations. Test links shall be installed on all connections to the relay to facilitate testing.Protection study and report shall be developed for the scheme to ensure the relay is suitable and required.Routine testing shall be undertaken as part of the testing of the protection schemePart numbers other than those listed below are not preferred and may be used only with the permission of the Head of Engineering – Electrical:• 0411L0X4X5C8CHXH52222XX o for 48V Substation with 5A CTs• 0411L0X4X1C8CHXH52222XX o for 48V Substation with 1A CTs• 0411L0X4X5C8CHXH52323XX o for 110-125V Substation with 5A CTs• 0411L0X4X1C8CHXH52323XX o for 110-125V Substation with 1A CTs

00313 1 Rebosio Strut and Post Insulators

the Earthing, Bonding and Electrolysis Mitigation Strategy, it was recommended that the 1500V DC traction system be electrically separated from the OHW mast using a single insulator with a basic insulator level (BiL) greater than 250kV and a flashover distance greater than 500mm.

Overhead Full Type Approval Approved I02080 (Strut Insulator), I02079 (Post Insulator NA NA Bonomi Italy For use on the CTD project Elevated Viaduct only. May be used in other areas of the network providing an insulation co-ordination report is conducted to the satisfaction of the Chief Engineer or Delegate.

00314 1 Lynx Series Industrial Ethernet Routing Switches

Full Layer 2 and Layer 3 capabilities including VPN, static and dynamic routing, firewall, cyber security features, network configuration management tools are supported. OCS Engineering

Approval Approved 17/08/2017 L210-F2G ; L208-F2G-S2 v10 4.21 Westermo Sweden

1. Purchasing:When deployed in a new geographic location for the first time, shall be purchased / supplied with the Westermo specific console cable (Part Number 1211-2027).2. Deployment:Shall be deployed with firmware version 4.20.0 or higher.

00316 1 SPX In Bearer Assembly The SPX In Bearer Assembly is an in-bearer assembly for the MKIII modular clamp lock point machine available with a hydraulic or electro-mechanical drive. Signals Provisional Type

Approval Approved 17/08/2017 15/11/2017 AP106230 - - SPX United Kingdom

1. The Provisional Type Approval is valid for the trial period which shall be concluded after three (3) months service from the date of installation. If the trial is unsuccessful, the point machine shall be removed.2. The user shall ensure that he/she is fully aware of and complies with the information given in “Executive Summary - MKIII SPX Clamplock Point Operating Machine”.3. Any changes to the SPX Clamplock In Bearer Assembly shall be detailed to MTM.4. SPX shall retain ISO 9001 accreditation and inform MTM of any change in accreditation.5. The SPX Clamplock In Bearer Assembly shall be installed as per the requirements given by SPX.6. Full Type Approval shall be conditional on the success of the trial to be agreed upon by Signals Engineering and Signals Delivery.

00317 1 Bluey GRP Soil Nails BluGeo GRP60 is a Glass-Fibre Reinforced Plastic continuously threaded solid bar which forms a high load carrying capacity ground anchor and soil nail. Structures Full Type Approval Approved 25/07/2017 BluGeo GRP60 - - Bluey Technologies China

• Bluey GRP Soil Nails shall be designed, installed and tested insitu in accordance with VicRoads Section 683 Soil Nail Walls.• Documentation shall be supplied for each batch of Bluey GRP Soil Nails delivered to site to evidence that the approved Quality Control procedures have been followed.• The manufacture, testing, supply, design and installation of BluGeo GRP60 shall comply with Bluey Technical Data Sheet code BG-50-00-000 R02/2017.• The supplier shall submit to MTM for its approval any revisions made to BG-50-00-000 R02/2017 where they may affect any of the following aspects of the product:- Performance characteristic- Form/ Fit/ Function- Place of manufacture- Installation/ operating process

00318 1 Phoenix Contact “Plug in Block” and also Connectors”

For use in Westrace MK2 Computer Based Interlocking and similar type applications within the MTM Melbourne Rail Network Signals Engineering

Approval Approved 26/07/2017 Due to multiple part numbers refer to submission form - - Pheonix connectors Germany Nil Conditions

00319 1 Tapered rail joint shims

Rail joint shims fit inside and along the upper fishing surface of mechanical joints to return them to their design longitudinal plan thereby eliminating dipped fish plated joints, voiding and mud holes in the area of joints.Unquantified savings will be made due to reduced maintenance, reactive works and reductions to PWM’s.

Track Provisional Type Approval Approved 16/08/2017 15/11/2017 AS47kg Joint Shim set - - Bance England

1. A 3 month trial shall be conducted at Lilydale siding, using shims for 47kg rail. A report shall be provided after the trial to validate and confirm successful performance in the field. Where a trial is found to be unsuccessful, the shims shall be removed from track.2. Bance Joint Shims shall not be used: • On Insulated rail joints; • On Crippled or battered rail ends; • On mismatched rails; and • To equalise rail end wear.3. Measurement of joint dip and installation of shims shall be carried out as per the manufacturer’s recommendation. Refer to Appendix 1 for details.4. Sleepers on either side of the joints, fitted with shims, shall be packed and consolidated to ensure joint is supported during the passage of a train

00323 1 100-50kVA 400/3300-2200V dYN11 Cast Resin Step-up Transformer Essential Services / Auxiliary Transformer Electrical Networks Provisional Type

Approval Approved 17/11/2017 TMT111003322-IP22-dYN11 N/A N/A TMC Australia

The transformer shall be installed indoors.

Requirement for the primary side circuit breaker shall be determined by the designer of the intended installation and an appropriate unit selected based on the protection discrimination requirements if required.

The transformer shall be used in conjunction with an Essential Services and Auxiliary Transformer conforming to MESP 050100-01.

00324 2 Weathering Steel - Cladding Used for cladding purposes(Engineering Product Approval covers cladding only) Structures Engineering

Approval Approved 28/08/2017

Bluescope XLERPLATE® to AS/NZS 3678 – WR350 and WR350L0

Bluescope TRU-SPEC® and Hot Rolled Coil to AS/NZS 1594 – HW350

Bluescope Cold Rolled Coil to AS/NZS 1595 – CW300-G

N/A N/A Bluescope Australia

00328 1 SEL Protective Relayuse in providing protection in MTM’s internal HV network. These will be located in substations within the LV compartment of the HV switchgear as an upgrade to the MiCOM P127 to accommodate additional protection functionality for the UPS installations.

Electrical Networks Full Type Approval Approved 20/09/2017SEL-751 / 751401DCD3D70830320 (for 110V or 125V DC Supplies) or 751402CCC3C70830320

(for 48V DC Supply)

Firmware:R200-V2 N/A Schweitzer Engineering

LaboratoriesWashington State, USA

The relay shall be installed and used in accordance with manufacturer recommendations. Test links shall be installed on all connections to the relay to facilitate testing.Protection study and report shall be developed for the scheme to ensure the relay is suitable and required.Routine testing shall be undertaken as part of the testing of the protection schemePart numbers other than those listed below are not preferred and may be used only with the permission of the Head of Engineering – Electrical:• 751402CCC3C70830320 o for 48V Substation with 1A CTs • 751401DCD3D70830320 o for 110-125V Substation with 1A CTs• 751402CCC3C70870320 o for 48V Substation with 5A CTs• 751401DCD3D70870320 o for 110-125V Substation with 5A CTs

00329 1 AUSGROUP Grade Acrylic Acrylic panels that offers light transmission matching that of glass, typically has higher strength and half the weight, and is commonly used for high traffic acoustic barriers. Structures Engineering

Product Approval Approved 8/02/2018 Noisewall Grade Acrylic N/A N/A PALRAM Israel

00330 1 StormPRO-Polypropylene Storm water pipe

StormPRO-Polypropylene Storm water pipe.• 6m Lengths approximately• Lightweight-Safer as no heavy machinery is required for pipe 150mm-450mm• Range 150mm-900mm• Rubber Ring joints Sewer quality Seal• Reduced root intrusion, minimal water and soil intrusion• SN8 Stiffness• Longer lengths then traditional drainage pipes• Flexible pipe ASNZ allows 7.5% deflection• 100mm-150mm connections• Range of fittings to suit-Bends, Tees, Reducers• No rebar exposure• High Chemical resistance• High Abrasion Resistance• Environmental Product Declaration (EPD)• Australian made

Structures Engineering Product Approval Withdrawn

p/n:29479 -150mm diameter - 150 StormPRO2 SN8 PP 6.020m lengthp/n:29456 -225mm diameter - 225 StormPRO2 SN8 PP 5.988m lengthp/n:29458 -300mm diameter - 300 StormPRO2 SN8 PP 5.941m lengthp/n:29460 -375mm diameter - 375 StormPRO2 SN8 PP 5.931m lengthp/n:29471 -450mm diameter - 450 StormPRO2 SN8 PP 5.948m lengthp/n:29473 -525mm diameter - 525 StormPRO2 SN8 PP 5.889m lengthp/n:29475 -600mm diameter - 600 StormPRO2 SN8 PP 5.848m lengthp/n:29418 -750mm diameter - 750 StormPRO SN8 PP 5.920m lengthp/n:29419 -900mm diameter - 900 StormPRO SN8 PP 5.910m length

N/A N/A Vinidex Australia

00331 1 Powerjoint - termination kit 1 core 500 sq.mm screened positive Aluminium cable indoor terminations Electrical Networks Engineering Approval Approved 30/08/2017 H61500MT01 Aluminium Lug & H6i500BLMMT03

Bimetal Lug N/A N/A Legend Power China For use on indoor 1500 volt equipment only

00332 1 Powerjoint - termination kit 1 core 500 sq.mm screened positive Aluminium cable outdoor terminations Electrical Networks Engineering Approval Approved 30/08/2017 H60500BLMT02 Bimetal Lug N/A N/A Legend Power China For use on outdoor 1500 volt equipment only

00333 1 Powerjoint - termination kit 3 core 35 sq. mm screened Cu cable Electrical Networks Engineering Approval Approved 30/08/2017 H6i1X2MT012 (outdoor) N/A N/A Legend Power China

• Approved 35 sq. mm cable as per L1-CHE-SPE-148 • For use in cable terminations inside Eaton Xiria switchgear• Type approved high voltage cable boots to be fitted over the termination

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

00334 1 Powerjoint - termination kit 3 core 185 sq.mm screened aluminium cable indoor terminations Electrical Networks Engineering Approval Approved 30/08/2017 H22iX3T2 (indoor) N/A N/A Legend Power China For use on indoor 22 kV cable terminations only

00335 1 Powerjoint - termination kit 3 core 185 sq.mm screened aluminium cable outdoor terminations Electrical Networks Engineering Approval Approved 30/08/2017 H22o1X3T3 (outdoor) N/A N/A Legend Power China For use on outdoor 22 kV cable terminations only

00338 1 DC-DC Converter To provide 48V DC supply from an existing 125V DC power supply. Electrical Networks Full Type Approval Rejected 13/11/2017 SD-500H-48 N/A N/A Mean Well Taiwan

00339 1 Junction Rail AS60kg – AS47kgFor use in the transition from different rail profiles, an example being new 60kg rail interfacing with existing 47kg rail. These will predominately be located in interfaces from new track and old.

Track Full Type Approval Approved 20/10/2017 440.081431.W01 N/A N/A Vossloh Australia

1. Welded junction rails shall be installed in accordance with the requirements of the Welded Track Management Manual with specific reference to closure rails and Section 4 of MTPR 033000-11 - Chapter 11, Rail Welding Process2. Welded junction rails shall be a minimum of 13.7m in length.3. Any variation in length shall be referred to the Track Delivery Manager for review and approval.

00340 1 Relocatable Equipment Building (REB)

Structure to house signalling equipment. Two types:

Small – 4955mm x 3305mm

Large – 6155mm x 3305mm

Both types have:• Two A/C’s, • A single step • Sloped roof with gutters and drain pipeEach structure can be either fire rated or non-fire rated.

To maintain the required signalling equipment environment when subject to all of the climatic conditions in Victoria. This includes allowance for a shade air temperature of –10 degrees Celsius to +45 degrees Celsius with a relative humidity of 95%

Signals Full Type Approval approved 24/11/2017 na

SRS Power Pty Ltd Large Size Fire rated Equipment Building

Dimensions: 6306L x 3494W x 3296H mmWeight: 4200 kgWall and ceiling type: MNERAL WOOL CORE 150mm THCK PANELSBush fire rating: - / 120/ 120 Drawing numbers: P03-000-C-CTD-DRG-00-CFD-ARC-(9009 to 9016)SRS Power Pty Ltd Large Size Non – Bush Fire rated Equipment Building

Dimensions: 6155L x 3443W x 3219H mmWeight: 2800 kgWall and ceiling type: XFLAM 75mm THCK PANELSDrawing numbers: P03-000-C-CTD-DRG-00-CFD-ARC-(9001 to 908)SRS Power Pty Ltd Small Size Fire rated Equipment Building

Dimensions: 5106L x 3494W x 3205H mmWeight: 3350 kgWall and ceiling type: MNERAL WOOL CORE 150mm THCK PANELSBush fire rating: - / 120/ 120 Drawing numbers: P03-000-C-CTD-DRG-00-CFD-ARC-(9083 to 9093)

SRS Power Pty Ltd Small Size Non-Bush Fire rated Equipment

N/A N/A Siemens Australia 1. A detailed design process shall be undertaken to identify any application and site specific requirements to determine the appropriate REB size and type.

00347 1 Relocatable Equipment BuildingTo maintain the required signalling equipment environment when subject to all of the climatic conditions in Victoria. This includes allowance for a shade air temperature of –10 degrees Celsius to +45 degrees Celsius with a relative humidity of 95%

Signals Full Type Approval Withdrawn Structure N/A N/A Siemens Australia/New Zealand

00349 1 Wavetrain Level Crossing Warning System (LCWS)

The application of this equipment is currently limited to the scope of the Wavetrain Wheel Flat Detection trial, which aims to determine the viability for additional use of the wavetrain sensors around the network. The trial will involve attaching the sensors at a specific location on the network for a set period of time.The wheel flat detection trial will take place on running line where there is a section of track clear of points and IRJs to reduce noise. This will allow for accurate modelling of train audio signatures. It has been proposed to choose the test site on the Craigieburn down line in order to capture the signatures of trains with wheel flats transferring to Craigieburn Depot for turning at the underfloor wheel lathe. This will increase the number of flats that pass the sensors in a given time frame and produce more accurate signatures.

Track Full Type Approval Withdrawn 1310-21741 1.3 1.3 WaveTrain Systems AS Norway Refer to e-mail from Jennifer Nguyen, WaveTrain EC .msg.

00350 1 MCE lightweight Portable Possession Limit Board Possession limit board Track Full Type Approval Approved 14/11/2017 MCE 205STK

Pads No 057/072981 N/A N/A MC Electronics United Kingdom

00351 1 MCE Lightweight Marker Board Possession limit board Track Full Type Approval Approved 14/11/2017 MCE 1402Pads No: 0020/039499 N/A N/A MC Electronics United

Kingdom

00352 1 Nord-Lock Washer (M24) Fastening Fish bolts in mechanical joints and mechanical insulated rail joints. Track Grandfather Rights Approved 17/11/2017 NL24 N/A N/A Nord-Lock Sweden Refer to e-mail from T&S -HoE,Trialed under EC:IF-14-089-PC

00353 1 Lock Nut (M24) Fastening Fish bolts in mechanical joints and mechanical insulated rail joints. Track Grandfather Rights Approved 17/11/2017 1651-0024-300-G-P N/A N/A Security Locknut USA Refer to e-mail from T&S -HoETrialed under EC:IF-14-067-PC

00354 1 Lock Nut (M27) Fastening heel bolts in Points and Crossings. Track Grandfather Rights Approved 17/11/2017 1603-0027-300-G-P N/A N/A Security Locknut USA Refer to e-mail from T&S -HoE

00363 1 Crimp Connection on bare aerial copper conductors Overhead Full Type Approval Approved GCE250-259 N/A N/A Panduit Mexico

The crimp can only be used to crimp the following conductors:181mm² catenary wire to 181mm² feeder wire181mm² catenary wire to 100mm² jumper wire161mm² catenary wire to 100mm² jumper wire

00366 1 SEL Protective 751A Relay Digital AC Protection Relay Substations Full Type Approval Approved 16/02/2018 SEL-751A - 751A52C0X0X0X841320 N/A N/ASchweitzer Engineering

LaboratoriesWashington State, USA

The relay shall be installed and used in accordance with manufacturer recommendations. Test links shall be installed on all connections of the relay to facilitate testing.Protection study and report shall be developed for the scheme to ensure the relay is suitable and required.Routine testing shall be undertaken as part of the testing of the protection schemePart numbers other than 751A52C0X0X0X841320 shall not be used without the approval of the Head of Engineering – Electrical.

00368 1 Minilogger Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved MINHCL-068-BM-103MINHCL-084-BM-103 N/A N/A Voestalpine Germany

00369 1 Minilogger HD Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved MINANG-531-BM-103MINANG-631-BM-103 N/A N/A Voestalpine Germany

00370 1 Minilogger 2 Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved

MINTWO-621-BM-103MINTWO-641-BM-102MINTWO-691-BM-103MINTWO-681-BM-103MINHCL-391-BM-103

N/A N/A Voestalpine Germany

00371 1 VT1 Minilogger Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 VT1HCL-003-BM-103 N/A N/A Voestalpine Germany00372 1 Router w/Magnetic Whip Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 ROUKIT-000-BM-006 N/A N/A Voestalpine Germany00373 1 Router w/Dome Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 ROUKIT-001-BM-006 N/A N/A Voestalpine Germany00374 1 Rail Temp Sensor 10m Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 RTSCAB-000-BM-002 N/A N/A Voestalpine Germany00375 1 Rail Temp Sensor 20m Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 RTSCAB-000-BM-004 N/A N/A Voestalpine Germany00376 1 Rail Temp Sensor Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 RTSCAB-0000-BM-005 N/A N/A Voestalpine Germany00377 1 Temp Thermistor Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 ETP-CS N/A N/A Voestalpine Germany00378 1 Ambient Temp Sensor Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 Ocean Controls KTD-267 N/A N/A Voestalpine Germany

00379 1 CRmagnetics CR4620-150 - AC Transducer Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 CTGKIT-000-BM-001 N/A N/A Voestalpine Germany

00380 1 Switch Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 NETKIT-000-BM-001 N/A N/A Voestalpine Germany00381 1 PCM CT (Unistar) Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 CTPLAT-100-BM-012 N/A N/A Voestalpine Germany00382 1 PCM CT Cable 2m Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 CTPLAT-102-BM-001 N/A N/A Voestalpine Germany00383 1 PCM CT Cable 4m Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 CTPLAT-104-BM-001 N/A N/A Voestalpine Germany00384 1 PCM CT Cable 5m Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 CTPLAT-105-BM-001 N/A N/A Voestalpine Germany00385 1 PCM CT Cable 12m Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 CTPLAT-112-BM-001 N/A N/A Voestalpine Germany00386 1 Router Cable Minilogger system used for remote condition monitoring of fixed assets Signals Grandfather Rights Approved 11/12/2017 EVNSL27E-0001-90DU N/A N/A Voestalpine Germany

00389 1TAKEX PHOTOELECTRIC BEAM SENSOR (INTELLIGENT QUAD

SERIES)Tunnel Intruder Detection Systems OCS Grandfather Rights Approved 18/12/2017 PB-IN-50HF N/A N/A Takex Japan Nil

00390 1TAKEX PHOTOELECTRIC BEAM

SENSOR ANTI-CRAWL HIGH SECURITY PHOTOBEAM

Tunnel Intruder Detection Systems OCS Grandfather Rights Approved 18/12/2017 PB-IN-100AT N/A N/A Takex Japan Nil

00405 1 Eaton 9PX UPS Eaton 9PX UPS OCS Engineering Product Approval Approved

3kVA Unit - 9PX3000IRT2U (with optional 9PXEBM72RT EBM)

6kVA Unit - 9PX6Ki (with optional 9PX EBM 180V EBM)

N/A N/A Eaton China and Philippines

Network-MS module shall be installed and connected to a central monitoring system.In locations that do not have temperature monitoring, the Environmental Monitoring Probe shall be installed.

00406 1 APC Transfer Switches The AP44xx range of Transfer Switches provides the capability of automatically switching to secondary power source should the primary source fails. OCS Engineering

Product Approval Approved10A Model – AP442116A Model – AP4423 N/A N/A APC China N/A

00407 1 NanoBeam wireless network bridge The Ubiquiti NanoBeam is a point-to-point wireless network bridge, allowing for the network connection of two buildings when it is impractical to run network cabling. OCS Engineering

Product Approval Approved NBE-5AC-Gen2 N/A N/A Ubiquiti China

Radio antenna shall be installed inside a sealed plastic junction box to provide additional weather and vandal protection.Redundant power supply options (e.g. UPS) shall be considered as part of a risk assessment.Device shall be configured to only use the following outdoor channels:5745,5750,5755,5760,5765,5770,5775,5780,5785,5790,5795,5800,5805,5810,5815,5820,5825

00409 1 Siemens ET200SP PLCProviding remote indication and/or control of plant equipment such as pumps,HVAC units, lifts, escalators, etc...). OCS Engineering

Product Approval Approved ET200SP N/A N/A Siemens Australia GermanyCP1543SP-1 shall be used for any upstream (non-local) network connections.Not to be used for vital signalling

00415 1 Layer 3 Switch & Modules Site Master Switch OCS Grandfather Rights Approved 26/02/2018 Summit x460-G2 24T (Part No 16701)Summit x460-G2 24X (Part No 16705) Refer to e-mail from Mark cole - 'OCS approved products.msg'

00416 1 Redundant, Hot pluggable 240V PSU, Extreme Networks Site Master Switch OCS Grandfather Rights Approved 26/02/2018

Summit x460 AC PSU (Part No. 10930 Standard Temperature Range)

Summit x460 AC PSU (Part No. 10930A Extended Temperature Range)

00417 1 Full Layer 3 license upgrade, Extreme Networks Site Master Switch OCS Grandfather Rights Approved 26/02/2018 ExtremeXOS Advanced Core License Upgrade

from Edge License (Part No. 16422)

00418 1 PlusOptics SFPs Optics OCS Grandfather Rights Approved 26/02/2018SFPs are ordered from PlusOptics to suit the

intended application i.e. switch vendor, OF type, wavelength, distance etc.

Refer OCS Engineering for assistance if required

00419 1 Allied Telesis 10GBE 1310nm XFP - 10km Single Mode 10GBE XFP / XENPACK OCS Grandfather Rights Approved 26/02/2018 AT-XPLR To be used for reactive/corrective maintnence only

Not be used in new installations or purchased.

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

00420 1 Allied Telesis 10GBE 1550nm XFP - 40km Single Mode 10GBE XFP / XENPACK OCS Grandfather Rights Approved 26/02/2018 AT-XPER40 To be used for reactive/corrective maintnence only

Not be used in new installations or purchased.

00421 1 Allied Telesis 1Gb 850nm SFP - 550m Multimode SFPs OCS Grandfather Rights Approved 26/02/2018 AT-SPSX To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00422 1 Allied Telesis 100Mb 1310nm SFP - 2km Multimode SFPs OCS Grandfather Rights Approved 26/02/2018 AT-SPFX-2 To be used for reactive/corrective maintnence only

Not be used in new installations or purchased.

00423 1 Hirschmann 1Gb 850nm SFP - 550m Multimode SFPs OCS Grandfather Rights Approved 26/02/2018 M-SFP-SX/LC To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00424 1 10/100/1000TX SFP (Copper) Copper SFPs OCS Grandfather Rights Approved 26/02/2018 AT-SPTX To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00425 1 8ch Single Core Mux Side 'A' CWDM Mux/DeMux OCS Grandfather Rights Approved 26/02/2018 MD-8CH-1RU-CWDM-1310-LCSX-A00426 1 8ch Single Core Mux Side 'B' CWDM Mux/DeMux OCS Grandfather Rights Approved 26/02/2018 MD-8CH-1RU-CWDM-1310-LCSX-B00427 1 48 VDC Hirschmann Switch Field LAN Switch Options OCS Grandfather Rights Approved 26/02/2018 Hirschmann MS30 Series

00428 1 Basic switch + backplane unit (16 port) Field LAN Switch Options OCS Grandfather Rights Approved 26/02/2018 MS30-1602TCAPHHXX.X

00429 1 Basic switch + backplane unit (24 port) Field LAN Switch Options OCS Grandfather Rights Approved 26/02/2018 MS30-2402TCAPHH06.0

00430 1 dual 1000baseSX interface Field LAN Switch Options OCS Grandfather Rights Approved 26/02/2018 MM4-2TX/SFP

00431 1 100baseFx interface module (for fibre connected cameras) Field LAN Switch Options OCS Grandfather Rights Approved 26/02/2018 MM3-4FXM2

00432 1 PoE 100baseT interface × 4 module Field LAN Switch Options OCS Grandfather Rights Approved 26/02/2018 MM22-4T100433 1 Expansion module - 2 port Field LAN Switch Options OCS Grandfather Rights Approved 26/02/2018 MB-2T00434 1 Summit layer 2 switch Field LAN Switch OCS Grandfather Rights Approved 26/02/2018 Summit-X430-24P(Part No 16517)

00435 1 Ethernet Extender Ethernet Extenders OCS Grandfather Rights Approved 26/02/2018 EtherWan ED3146-22B To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00436 1 Ethernet Remote Terminal Unit Controller Remote Terminal Unit Controllers OCS Grandfather Rights Approved 26/02/2018 Moxa ioLogik E2210-T

00437 1 IP Fixed Camera for CHP's and choke points CCTV OCS Grandfather Rights Approved 26/02/2018 DVTel Quasar CF-4221-00

00438 1 IP Fixed Camera with integral analitics CCTV OCS Grandfather Rights Approved 26/02/2018 DVTEL Quasar CF-5222-00To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.Requires Latitude 6.3 Camera Pack 1

00439 1 2.8-10.0 mm f1.2 varifocal Megapixel lens CCTV OCS Grandfather Rights Approved 26/02/2018 Computar AG4Z2812FCS-MPIR

00440 1 8.0 – 50.0 mm f1.6 varifocal HD IR lens CCTV OCS Grandfather Rights Approved 26/02/2018 Tamron M13VG850IR (s45379)

00441 1 IP PTZ Dome Camera, POE+ CCTV OCS Grandfather Rights Approved 26/02/2018 DVTel Quasar CP-4221-301 Heater/demister function inoperative on POE+

00442 1 POE+ Injector for use with CP-4221-201 PTZ CCTV OCS Grandfather Rights Approved 26/02/2018 Moxa INJ-24A-T

00443 1 Analogue Camera (24V AC or 12V DC), normal duty. CCTV OCS Grandfather Rights Approved 26/02/2018 Panasonic SD634 Model No: WVC-P634 WV-CP634

00444 1 Fixed Camera Housing, in line - Pelco CCTV OCS Grandfather Rights Approved 26/02/2018 EH3512

00445 1 Fixed Camera Housing Wall Mount High Security CCTV OCS Grandfather Rights Approved 26/02/2018 CMH02WM

00446 1 Fixed Camera Housing, in line - Pelco CCTV OCS Grandfather Rights Approved 26/02/2018 EH4712DB Special order fitted with 268 lock barrel

00447 1Corner-mount Camera Housing with

12mm glass and security screws - SEE Security

CCTV OCS Grandfather Rights Approved 26/02/2018 CHM02 with adaptor kit

00448 1Wedge Camera Housing with 12mm

glass and security screws - SEE Security

CCTV OCS Grandfather Rights Approved 26/02/2018 SMW5 with adaptor kit

00449 1Recessed Wedge Camera Housing with 12mm glass and security screws - SEE

SecurityCCTV OCS Grandfather Rights Approved 26/02/2018 RMW5 with adaptor kit

00450 1 Mounting bracket – For mounting EH3512 to building CCTV OCS Grandfather Rights Approved 26/02/2018 EM1450

00451 1 Mounting bracket – For mounting EH3512 to pole CCTV OCS Grandfather Rights Approved 26/02/2018 EM2000

00452 1

Mounting bracket – For mounting EH3512 to top of pole (if pole does not come with mounting bracket) or under

roof

CCTV OCS Grandfather Rights Approved 26/02/2018 EM1009U & EM1015U

00453 1

Mounting bracket – For mounting EH3512 to top of pole (if pole does not come with mounting bracket) or under

roof

CCTV OCS Grandfather Rights Approved 26/02/2018 MM22

00454 1Mounting bracket for PTZ dome camera

– suitable for mounting to wall type surface

CCTV OCS Grandfather Rights Approved 26/02/2018 IWM24-GY

00455 1 Adaptor plate for PTZ CCTV OCS Grandfather Rights Approved 26/02/2018 FX-150

00456 1 Mounting bracket for IWM24-GY on pole CCTV OCS Grandfather Rights Approved 26/02/2018 PA402

00457 1 Mounting bracket for IWM24-GY on corner CCTV OCS Grandfather Rights Approved 26/02/2018 CM400

00458 1Security screws for camera mounting brackets and housings (Keys available

from MTM only) - Austra GoldCCTV OCS Grandfather Rights Approved 26/02/2018 F7 Barrinuts from Austra Gold (small & large

formfactor available)

00459 1225 serries padlock for camera housings (keyed CL001) - API

LocksmithsCCTV OCS Grandfather Rights Approved 26/02/2018 225/40/119/LF

00460 1 6-12 port 12VDC Video Distribution Amplifier CCTV OCS Grandfather Rights Approved 26/02/2018 Pacom VDA816PR1

00461 1 16 Channel Encoder 12VDC CCTV OCS Grandfather Rights Approved 26/02/2018 DVT-7608E

00462 1 8 Channel Encoder with audio 12VDCc CCTV OCS Grandfather Rights Approved 26/02/2018 DVT-EV208-A

00463 1 16 Channel Encoder with audio 12VDC CCTV OCS Grandfather Rights Approved 26/02/2018 DVT-EN216

00464 1 Single Channel Encoder with audio 12VDC CCTV OCS Grandfather Rights Approved 26/02/2018 DVT-7801EA

00465 1Single Channel Encoder with audio POE, extended temperature range

(Inside Field LAN Switch assemblies)CCTV OCS Grandfather Rights Approved 26/02/2018 DVT-7401ETA

00466 1 Single Channel Decoder 12V dc CCTV OCS Grandfather Rights Approved 26/02/2018 DVT-7401DA

00467 1 UPS Environmental Monitoring probe - For all UPS types SNMP Alarm Interface / UPS OCS Grandfather Rights Approved 26/02/2018 Powerware Environmental Monitoring Probe (EMP)

00468 1 UPS SNMP Card - For all UPS types SNMP Alarm Interface / UPS OCS Grandfather Rights Approved 26/02/2018 ConnectUPS-MS Network Management Card

00469 1 6 kVA UPS (Note: may need electrician to install) UPS OCS Grandfather Rights Approved 26/02/2018 9SX6KiRT To be used for reactive/corrective maintnence only

Not be used in new installations or purchased.

00470 1 UPS Extended Battery Module UPS OCS Grandfather Rights Approved 26/02/2018 9SXEBM180RT To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00471 1 3 kVA UPS UPS OCS Grandfather Rights Approved 26/02/2018 9PX3000IRTN To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00472 1 UPS Extended Battery Module UPS OCS Grandfather Rights Approved 26/02/2018 9PXEBM72RT2U To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00473 1 Automatic Transfer Switch Power OCS Grandfather Rights Approved 26/02/2018 American Power Conversion (APC) AP7723 To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00474 1 UPS Distribution Box Power OCS Grandfather Rights Approved 26/02/2018 WMDIN2

00475 1 48 V dc power supply – Fitted with 10 x 6A load circuit breakers CCTV OCS Grandfather Rights Approved 26/02/2018

Eaton Powerware APS3-320 rectifier system including APR48-3G × 2 (1+1) 31A 48V, rectifiers, integral 10-way load distribution, Control module

SC200, and separate power supply to each rectifier (multiple AC option)

00476 1 48 V dc power supply – Fitted with 20 x 6A load circuit breakers CCTV OCS Grandfather Rights Approved 26/02/2018

Eaton Powerware APS6-320 rectifier system including APR48-3G × 2 (1+1) 31A 48V, rectifiers, integral 20-way load distribution, Control module

SC200, and separate power supply to each rectifier (multiple AC option)

00477 1 48V - 12V dc-dc converter for 12V PTZ cameras CCTV OCS Grandfather Rights Approved 26/02/2018 Mean Well SD-100C-12

00478 1 240V-12V ac-dc power supply general purpose CCTV OCS Grandfather Rights Approved 26/02/2018 Mean Well DR-120-12

00479 1 12 V dc Power Supply for encoders CCTV OCS Grandfather Rights Approved 26/02/2018 Tactical Technologies RPS12-20DC-D20

00480 1 24V ac Power supply for analogue cameras CCTV OCS Grandfather Rights Approved 26/02/2018 Tactical Technologies RPS24-10-D10-2RU

00481 1 Removed - requirement in Specification Racks OCS Grandfather Rights Approved 26/02/2018 As per CCTV Specification As per CCTV Specification

00482 1 1RU KVM - 17" LCD monitor - Multiple input Accessories OCS Grandfather Rights Approved 26/02/2018 ATEN CL5708MA To be used for reactive/corrective maintnence only

Not be used in new installations or purchased.

00483 1 KL1508MA-I Aten 19" rack mount 8 port KVM over IP Switch with 17" screen Accessories OCS Grandfather Rights Approved 26/02/2018 S46283 To be used for reactive/corrective maintnence only

Not be used in new installations or purchased.

00484 1 8 & 16 port Coax Ethernet & POE Extender IP Over Coax cable OCS Grandfather Rights Approved 26/02/2018 Vi2608A/Vi2616A Standards Waiver Required For Use Of this Equipment

Approved for use in Analogue CCTV Renewals Project Only

00485 1 Mini High Speed Ethernet Mini Extender Over Coax Cables IP Over Coax cable OCS Grandfather Rights Approved 26/02/2018 Vi2400A Standards Waiver Required For Use Of this Equipment

Approved for use in Analogue CCTV Renewals Project Only

00486 1 High Speed Ethernet Mini Extender Over Coax Cables IP Over Coax cable OCS Grandfather Rights Approved 26/02/2018 V12401A Standards Waiver Required For Use Of this Equipment

Approved for use in Analogue CCTV Renewals Project Only

00487 1 4 port High Speed Ethernet Extender over Coax IP Over Coax cable OCS Grandfather Rights Approved 26/02/2018 V2404A Standards Waiver Required For Use Of this Equipment

Approved for use in Analogue CCTV Renewals Project Only

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

00488 1 PC Workstations, Monitors, Servers and Storage equipment PC Workstations, Monitors, Servers and Storage equipment OCS Grandfather Rights Approved 26/02/2018 For current equipment standards refer to OCS Engineering Manager

00489 1 Challenger Security Master Panel Security & Access Control OCS Grandfather Rights Approved 26/02/2018 TS101600490 1 Memory Expansion Security & Access Control OCS Grandfather Rights Approved 26/02/2018 TS108200491 1 16 Input Collector Card Security & Access Control OCS Grandfather Rights Approved 26/02/2018 TS084200492 1 IP Ethernet Card Security & Access Control OCS Grandfather Rights Approved 26/02/2018 TS009900493 1 Remote Arming Station Security & Access Control OCS Grandfather Rights Approved 26/02/2018 CA1110

00494 1 74DC + 2 x Card Readers (Heavy duty) V7 Compatible Firmware Security & Access Control OCS Grandfather Rights Approved 26/02/2018 TS0866KH

00495 1 74DC + 2 x Card Readers (Heavy duty) V10 Compatible Firmware Security & Access Control OCS Grandfather Rights Approved 26/02/2018 TS0866KH

00496 1 Card Reader (Heavy duty) Security & Access Control OCS Grandfather Rights Approved 26/02/2018 TS0870H00497 1 Data Gathering Panel Security & Access Control OCS Grandfather Rights Approved 26/02/2018 TS102000498 1 8 Input Expansion Module Security & Access Control OCS Grandfather Rights Approved 26/02/2018 TS102100499 1 LAN Distribution Board Security & Access Control OCS Grandfather Rights Approved 26/02/2018 TS084400500 1 Fibre Interface Card Security & Access Control OCS Grandfather Rights Approved 26/02/2018 TS0896B00501 1 Universal Enclosure Security & Access Control OCS Grandfather Rights Approved 26/02/2018 TS030700502 1 Electronic Mortice Lock Security & Access Control OCS Grandfather Rights Approved 26/02/2018 3570ELM0SC00503 1 3570 External Plate with Lever Security & Access Control OCS Grandfather Rights Approved 26/02/2018 S1541A00504 1 3570 Internal Plate with Lever Security & Access Control OCS Grandfather Rights Approved 26/02/2018 S1542A00505 1 Power Transfer Lead 300mm Security & Access Control OCS Grandfather Rights Approved 26/02/2018 S452800506 1 Double Electric Lock - Padde Security & Access Control OCS Grandfather Rights Approved 26/02/2018 Z8 EML10

00507 1 Lokitwell K series 2-pole Ezy2 Key Override Security & Access Control OCS Grandfather Rights Approved 26/02/2018 EZY2

00508 1 Electric Strike – Padde Security & Access Control OCS Grandfather Rights Approved 26/02/2018 ES900000509 1 Electric Strike – Padde Security & Access Control OCS Grandfather Rights Approved 26/02/2018 ES2000

00510 1 Standard Door Reed Switch – Sentrol (Recessed) Security & Access Control OCS Grandfather Rights Approved 26/02/2018 1078

00511 1 Triple Bias Door Reed Switch - Sentrol Security & Access Control OCS Grandfather Rights Approved 26/02/2018 2707A

00512 1 Triple Bias Door Reed Switch for Double leaf Doors with Maglock- Sentrol Security & Access Control OCS Grandfather Rights Approved 26/02/2018 2767-L

00513 1 Heavy Duty Reed Switch – Sentrol Security & Access Control OCS Grandfather Rights Approved 26/02/2018 2202A

00514 1 Roller Shutter Door Reed Switch – Sentrol Security & Access Control OCS Grandfather Rights Approved 26/02/2018 2302A

00515 1 Aritech PIR Detector Security & Access Control OCS Grandfather Rights Approved 26/02/2018 EV66900516 1 Smoke Detector Security & Access Control OCS Grandfather Rights Approved 26/02/2018 ESL449CSTN-AA

00517 1 PIDS Display LED – 2 line Single Sided Pass Info Displays & Clocks OCS Grandfather Rights Approved 26/02/2018 Display Logic 2 Line Single Sided Character Per Line

To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00518 1 PIDS Display LED – 2 line Double Sided Pass Info Displays & Clocks OCS Grandfather Rights Approved 26/02/2018 Display Logic 2 Line Double Sided 20 Character To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00519 1 PIDS Display LED – 4 line Single Sided Pass Info Displays & Clocks OCS Grandfather Rights Approved 26/02/2018 Display Logic 4 Line Single Sided 40 Character Per Line

To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00520 1 PIDS Display LED – 4 line Double Sided Pass Info Displays & Clocks OCS Grandfather Rights Approved 26/02/2018 Display Logic 4 Line Double Sided 40 Character Per Line

To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00521 1 Platform Digital Clock LED 100mm (single or double sided) Pass Info Displays & Clocks OCS Grandfather Rights Approved 26/02/2018 AD Engineering AD312-150 NTP Clock & optional

GPS reciever

00522 1 Signal Box Digital Clock LED 50mm (single or double sided) Pass Info Displays & Clocks OCS Grandfather Rights Approved 26/02/2018 AD Engineering AD312-50 NTP Clock & optional

GPS reciever

00523 1 VOIP PBX (Server) - 8 VOIP intercoms/phones VOIP Intercom OCS Grandfather Rights Approved 26/02/2018 Epygi Quadro 2x

00524 1 Expand Quadro 2x to 16 intercoms/phones VOIP Intercom OCS Grandfather Rights Approved 26/02/2018 Quadro2x IP Phone Expansion Key

00525 1 VOIP PBX (Server) - 32 VOIP intercoms/phones VOIP Intercom OCS Grandfather Rights Approved 26/02/2018 Epygi Quadro M8L

00526 1 Desktop VOIP intercom (phone) VOIP Intercom OCS Grandfather Rights Approved 26/02/2018 Yealink SIP-T28PG

00527 1 Outdoor VOIP intercom – 1 button vertical VOIP Intercom OCS Grandfather Rights Approved 26/02/2018 Dallas Delta GUARDMK2VOIP1V

00528 1 Outdoor VOIP intercom – 1 button horizontal VOIP Intercom OCS Grandfather Rights Approved 26/02/2018 Dallas Delta GUARDMK3VOIP1H

00529 1 CHP Phone Assembly Analogue Red Button CHP OCS Grandfather Rights Approved 26/02/2018 Century DCOM1BHPTCAGC

00530 1 CHP Phone Assembly Analogue Red & Green Button CHP OCS Grandfather Rights Approved 26/02/2018 Century DCOM2BHPTCAGC

00531 1 CHP Intercom Mounting Panel CHP OCS Grandfather Rights Approved 26/02/2018 Custom manufactured by Metlink

00532 1 CHP stankess steel surface mount shroud CHP OCS Grandfather Rights Approved 26/02/2018 ENCSSH ENC 270x130 Horizontal SS

00533 1 Intercom unit - Dallas Delta CHP OCS Grandfather Rights Approved 26/02/2018 SentryBK10-LST

00534 1 Modular Amplifier 680W PA System OCS Grandfather Rights Approved 26/02/2018 TOA DA-250F To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00535 1 Modular Amplifier 340W PA System OCS Grandfather Rights Approved 26/02/2018 TOA DA-250D To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00536 1

Plug-in modules for Power Amplifier- Balanced Line / Unbalanced Mic Input

(10kΏ) with Vox and dual mute bus support

PA System OCS Grandfather Rights Approved 26/02/2018 TOA ML-11T To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00537 1 8 Channel Mixer Preamplifier PA System OCS Grandfather Rights Approved 26/02/2018 TOA M-900MK2 To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00538 1 Sound Web London Signal Processor PA System OCS Grandfather Rights Approved 26/02/2018 BLU-100 Approved for use at Flinders Street Station Only00539 1 Crown Power Amplifier PA System OCS Grandfather Rights Approved 26/02/2018 DCI Analogue 2-1250 Approved for use at Flinders Street Station Only

00540 1

Outdoor Horn Speakers 15W (only for coverage extension of existing SC-615M

horn speaker systems, not for use on new or fully redeveloped platforms)

PA System OCS Grandfather Rights Approved 26/02/2018 TOA SC-615M

00541 1 Outdoor Speakers 6W (poles on new platforms, also under canopy) PA System OCS Grandfather Rights Approved 26/02/2018 TOA CS-64

00542 1 Outdoor Under Canopy Speakers or indoor (surface bracket) PA System OCS Grandfather Rights Approved 26/02/2018 TOA PJ-100W

00543 1 Indoor Flush Ceiling Speakers PA System OCS Grandfather Rights Approved 26/02/2018 TOA PC-1869

00544 1 Free standing desktop microphone with PTT PA System OCS Grandfather Rights Approved 26/02/2018 Redback A2086 To be used for reactive/corrective maintnence only

Not be used in new installations or purchased.

00545 1 Free standing desktop microphone with PTT and zone selection PA System OCS Grandfather Rights Approved 26/02/2018 Redback A4585

00546 1UHF cordless microphone receiver

configurable to one of 64 Channels, with antenna distribution for

PA System OCS Grandfather Rights Approved 26/02/2018 TOA WT5800FO1AS

00547 1 Hand held UHF cordless microphone, configurable for 64 channels PA System OCS Grandfather Rights Approved 26/02/2018 TOA WM5265FO1AS

00548 1 UHF Antenna for cordless mic receiver PA System OCS Grandfather Rights Approved 26/02/2018 TOA YW4500

00549 1 Extended Zone Speaker Switchbox PA System OCS Grandfather Rights Approved 26/02/2018 Refer to Drawing SS00/615To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.Custom fabricated

00550 1 Techniplan Remote PA Access Modules PA System OCS Grandfather Rights Approved 26/02/2018

System Interface Module (SIM)Line Isolation Module (LIM)Tone Detect Module (TDM)

Teleswitch ModuleVox Monitor Module (VOX/MON)

To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.Techniplan Systems & Components Can Only be Sourced From MTM Infrastructure Operations - OCS - PIDS

00551 1 Large Loop AFILS Amplifiers OCS Grandfather Rights Approved 26/02/2018 LIC XL-2000 (covers up to 2000m2) [requires external 50:1 transformer for input from 100V line]

00552 1 Medium Loop AFILS Amplifiers OCS Grandfather Rights Approved 26/02/2018 Bosch PLN-1LA10 (covers up to 600m2) [has inbuilt screw terminal 100V balanced line input]

00553 1 Small Loop AFILS Amplifiers OCS Grandfather Rights Approved 26/02/2018 LIC XL-150 (covers up to 150m2) [requires external 50:1 transformer for input from 100V line]

00554 1 Base Switch, 240V powered must have redundant power option Core Network Switch OCS Grandfather Rights Approved 26/02/2018 Summit x460-24t/x/p (Part No. 16401) To be used for reactive/corrective maintnence only

Not be used in new installations or purchased.

00555 1 Redundant, Hot pluggable 240V PSU, Extreme Networks Core Network Switch OCS Grandfather Rights Approved 26/02/2018 Summit x460 AC PSU (Part No. 10930) To be used for reactive/corrective maintnence only

Not be used in new installations or purchased.

00556 1 2 x SFP+ Option Card Core Network Switch OCS Grandfather Rights Approved 26/02/2018 XGM3-2SF (Part No. 16117) To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00557 1 Basic Layer-2 ethernet switch Non-Core Network Switch OCS Grandfather Rights Approved 26/02/2018 Summit X430-24p To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00558 1 RuggedComm RX1500 RX1500 Field Switch OCS Grandfather Rights Approved 26/02/2018 RX1500-L3 RX1500 8 Gigabit Layer 3 w/ 4 LM slots and 2 PM slot00559 1 48vDC Power Module RX1500 Field Switch OCS Grandfather Rights Approved 26/02/2018 48 48VDC (36-72VDC), screw terminal block00560 1 High-Range Power Module RX1500 Field Switch OCS Grandfather Rights Approved 26/02/2018 HI 88-300 VDC or 85-264VAC, screw terminal block00561 1 10-FL Module RX1500 Field Switch OCS Grandfather Rights Approved 26/02/2018 FL01 3x 10FL Multimode 850nm ST 2km00562 1 100-tx Module RX1500 Field Switch OCS Grandfather Rights Approved 26/02/2018 6TX01 6x 10/100TX RJ4500563 1 1000-SFP Module RX1500 Field Switch OCS Grandfather Rights Approved 26/02/2018 FG50 2x 1000LX SFP Blank (no optical transceiver)00564 1 3G Module RX1500 Field Switch OCS Grandfather Rights Approved 26/02/2018 W11 1x GSM/EDGE/HSPA00565 1 RuggedComm RX1400 RX1400 Field Switch OCS Grandfather Rights Approved 26/02/2018 6GK6014-0A00566 1 Netcomm M2M Router 4G/3G Router OCS Grandfather Rights Approved 26/02/2018 NTC-140W-0200567 1 Juniper SRX240 Firewall OCS Grandfather Rights Approved 26/02/2018 SRX240-H2 Requires ATS to provide redundant power00568 1 1-Port Gigabit Ethernet SFP Mini-PIM Firewall OCS Grandfather Rights Approved 26/02/2018 SFP Mini-PIM00569 1 Cisco ASA5505 Firewall OCS Grandfather Rights Approved 26/02/2018 Cisco-ASA5505

Metro Trains Melbourne Approved Engineering Product List As of 01/03/2018

Uncontrolled if printed. Controlled by MTM Process and Interface [email protected]

Number Certificate Issue Title/Product Function/Application(s) Applicable

System(s) Approval Type Approval Status Approval Date Expiry Type/Model Number Hardware Revision No.

Software Version No. Manufacturer's Details Place of

ManufactureCondition and Service Restrictions

00570 1 APC Automatic Transfer Switch (ATS) ELECTROL SCADA UPS/Power OCS Grandfather Rights Approved 26/02/2018 AP7723, AP7721 To be used for reactive/corrective maintnence onlyNot be used in new installations or purchased.

00571 1 UPS ELECTROL SCADA UPS/Power OCS Grandfather Rights Approved 26/02/2018 Eaton Evolution 115000572 1 UPS ELECTROL SCADA UPS/Power OCS Grandfather Rights Approved 26/02/2018 Eaton 5P 1150

00573 1 Fan module Site Master LAN / ELECTROL SCADA Switch options OCS Grandfather Rights Approved 26/02/2018 Summit Fan module FB for Summit X460-G2 Series Switches (Part No. 10945)

00574 1 Expansion Module - 2 x SFP+ Site Master LAN / ELECTROL SCADA Switch options (Summit X460-G2 VIM-2x - Optional Virtual Interface Module (Part No. 16711)) OCS Grandfather Rights Approved 26/02/2018 Summit X460-G2 VIM-2x - Optional Virtual

Interface Module (Part No. 16711)

00575 1 Expansion Module - 2 x Stack Ports Site Master LAN / ELECTROL SCADA Switch options OCS Grandfather Rights Approved 26/02/2018 Summit X460-G2 VIM-2ss - Optional Virtual Interface Module (Part No. 16713)

00576 1 Mounting bracket – J mount bracket for mounting EH3512 to building CCTV OCS Grandfather Rights Approved 26/02/2018 EM1900U

00577 1 LCD Monitor SPOT OCS Grandfather Rights Approved 26/02/2018 PACOM 215LED-MET-NG (Modified to suit SPOT functionality)

00578 1 Wide Gap Reed Switch - Sentrol Security & Access Control OCS Grandfather Rights Approved 26/02/2018 2505A00579 1 Stainless Steel Duress button Security & Access Control OCS Grandfather Rights Approved 26/02/2018 PADP2

00580 1 Emergency Glass Break Release White DPDT - KAC Security & Access Control OCS Grandfather Rights Approved 26/02/2018 MCP4A-WOOOSG-HO69-OI

00581 1 Flat Panel 47" LCD PID – Single Sided Pass Info Displays & Clocks OCS Grandfather Rights Approved 26/02/2018 MS-47-2000 (Single Sided)Brackets ordered seprately.

00582 1 Flat Panel 47" LCD PID – Double Sided Pass Info Displays & Clocks OCS Grandfather Rights Approved 26/02/2018 MS-47-2000 (Double Sided)Brackets ordered seprately.

00583 1 Flat Panel PID Display PC - FitPC4 Pass Info Displays & Clocks OCS Grandfather Rights Approved 26/02/2018FitPC4 Pro Barebone. No HDD/SSD, No Wifi, 4GB

RAM, Hardened VESA mounting bracket for fit-PC3/4/IPC

00584 1Modular Powered 8x8 Matrix Mixer with 2 x 500W 100V line outputs (incl. 1 x

D001T) - TOAPA System OCS Grandfather Rights Approved 26/02/2018 TOA A9500D2

00585 1 Dual Mic/Line Input Module for 9000 Series - TOA PA System OCS Grandfather Rights Approved 26/02/2018 TOA D001T

00586 1 Dual Line Output Module for 9000 Series - TOA PA System OCS Grandfather Rights Approved 26/02/2018 TOA T001T

00587 1 Ambient Noise Control Module - TOA PA System OCS Grandfather Rights Approved 26/02/2018 TOA AN001T

00588 1 Outdoor Sound Column Speakers 10W (slimline) PA System OCS Grandfather Rights Approved 26/02/2018 Australian Monitor CS210

00589 1 2x8ch Single Core Mux Side 'A&B' CWDM Mux/DeMux OCS Grandfather Rights Approved 26/02/2018 MD-8CH-1RU-CWDM-1310-LCSX-A&B

00590 1 1RU Dell KVM - LED monitor & Mounting bracket Accessories OCS Grandfather Rights Approved 26/02/2018

Dell DKMMLED185-001Dell DRMK-77