metal roofing & siding systems - building materials, products
TRANSCRIPT
www.ultraseam.com
From the Arctic to the Equator - Providing Long Lasting Protection for All Climates
®
Metal Roofing & Siding Systems
07 61 00 / ULTBuyLine 2486
2486_01.qxd 8/9/05 8:22 AM Page 1
1"
w/STIFFENER BEADS
12" OR 16"12", 14", 16" AND 18"
112"
12", 16", 18" AND 20"
1"12", 16", AND 20"
112"
2"
12", 14", 16" AND 18"
US-175LS LOCK SEAM
US-150CL STANDING SEAM
US-200 MECHANICALLYSEAMED
US-100CS STANDING SEAM
The Ultra Seam standing seam systems utilize state of the art technology for roof and wall integrity and p o s i t i v e w e a t h e r -tightness. Our continuing interest and expertise in the Architectural Metal industry has enabled us to design, manufacture, and install products of the highest quality at a com-petitive cost with timely performance.All our roofing systems are designed to meet the highest quality standards, as well as the simplest installation requirements. They also offer the tools for design flexibility with high level of aesthetic quality.Whether your require-ments are low or steep slope, mansards, retrofit, fascias, coping, soffits, walls, or equipment screens, Ultra Seam has a suitable system. These systems can span across purlins on typical spacing, or laid directly over rigid insulation and/or solid decking. We offer many combinations of panel widths, rib heights and seam profiles, for differ-ent architectural applica-tions.
UL90 Rated ASTM E-1646 Water Penetration Tested
ASTM E-1680 Air Infiltration Tested ASTM E-1592 Tested
UL90 Rated 100 mph Wind Driven Rain Infiltration Resistance Tested
UL90 Rated ASTM E-1646 Water Penetration Tested
ASTM E-1680 Air Infiltration Tested ASTM E-1592 Tested
ASTM E-331Water Infiltration Tested ASTM E-283 Air Infiltration Tested
12", 14", 16", AND 18"
134"
US-150 MECHANICALLYSEAMED
UL90 Rated ASTM E-1646 Water Penetration Tested
ASTM E-1680 Air Infiltration Tested ASTM E-1592 Tested
US-100FP FLUSH PANEL
www.ultraseam.com
Florida Product Approval
Florida Product Approval
Florida Product Approval
Florida Product Approval
2486_02.indd 22486_02.indd 2 11/5/2007 7:43:39 AM11/5/2007 7:43:39 AM
12", 14", 16", AND 18"
112"
16" AND 18"
2"
12", 16", 18" AND 20"
1"
112"
12" - 22"
BATTEN PANEL
ASTM E-331Water Infiltration Tested ASTM E-283 Air Infiltration Tested
•Curving available in a minimum 10’-0” radius•
US-100CSC CURVED/TAPEREDROOFING SYSTEM
US-200C MECHANICALLY SCURVED PANEL SYSTEM
•Curving available in a minimum 20’-0” radius•
UL90 Rated ASTM E-1646 Water Penetration Tested
ASTM E-1680 Air Infiltration Tested ASTM E-1592 Tested
US-150C MECHANICALLY SEAMEDCURVED PANEL SYSTEM
UL90 Rated ASTM E-1646 Water Penetration Tested
ASTM E-1680 Air Infiltration Tested ASTM E-1592 Tested
EAMED
7" BOX GUTTER
4" x 5" OUTLET
4" x 5" DOWNSPOUT
4" x 5" ELBOW
7" HIDDEN HANGER
7" END CAP
US-700CG COMMERCIALGUTTERS
For specifications and details, visit www.ultraseam.com.
2486_03.indd 32486_03.indd 3 10/16/07 6:51:26 AM10/16/07 6:51:26 AM
Seward Recreation Camp – Seward, Alaska Architect: Cash Barner Usher ArchitectsAlaska District Corps of Engineers
14432 State Route 141 S.Pride, Kentucky 42437Tel: (270) 333-9552Fax: (270) 333-9702
8059 Crile RoadPainesville, Ohio 44077Tel: (440) 352-7800Fax: (440) 352-7048
3400 International St.Fairbanks, Alaska 99701Tel: (907) 456-3089Fax: (907) 456-4079
91-079 Makokole St.Kapolei, Hawaii 96707Tel: (808) 682-8090Fax: (808) 682-8095
2204 West Front StreetStatesville, NC 28677Tel: (704) 871-8704Fax: (704) 871-1381
8660 Lambright StreetHouston, Texas 77075Tel: (713) 991-2202Fax: (713) 991-4747
1300 40th StreetDenver, Colorado 80205Tel: (303) 292-1511Fax: (303) 292-1676
4530 126th Ave. N.Clearwater, Florida 33762Tel: (727) 573-2255Fax: (727) 573-2330
67 Benson AvenueHamilton, NJ 08610Tel: (609) 586-4411Fax: (609) 586-4422
17891 Ryan RoadDetroit, Michigan 48212Tel: (313) 893-9810Fax: (313) 893-9815
4333 Lynwood CourtDouglasville, Georgia 30134Tel: (770) 920-1931Fax: (770) 920-6838
P.O. Box 9017Houma, Louisiana 70361Tel: (985) 872-4511Fax: (985) 879-4551
10371 Airline HwySt. Rose, Louisiana 70087Tel: (504) 464-7485Fax: (504) 464-6011
4328 East MagnoliaPhoenix, AZ 85034Tel: (602) 437-9323Fax: (602) 437-9274
P.O. Box 1450Briarcliff Manor, NY 10510Tel: (914) 762-5311Fax: (914) 762-5434
121 County Rd. 11400Paris, TX 75462Tel: (903) 783-0058Fax: (903) 783-7868
3270 Associates Dr., Unit ACharleston, SC 29418Tel: (843) 767-0393Fax: (843) 767-8290
YOUR ULTRA SEAM PLANTS ARE LOCATED NATIONWIDE
© Copy Right 2004
Ultra Seam Headquarters1-800-USI-SEAM1-800-874-7326www.ultraseam.com
2486_04.qxd 11/8/07 3:28 PM Page 4