metal panel product performance testing seminar
TRANSCRIPT
![Page 1: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/1.jpg)
Product Product Performance Performance
TestingTestingMarch 16, 2015Roger A. Wallace, CSI, AIAAlliance Steel, Inc.Architectural Products Division
![Page 2: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/2.jpg)
Learning ObjectivesLearning Objectives
Section 1: Thermal MovementSection 2: Paint Finish TestingSection 3: Air, Water And Impact TestingSection 4: Wind Uplift TestingSection 5: Fire Resistance TestingSection 6: Common Metal Roof Problems
![Page 3: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/3.jpg)
Section 1: Thermal Movement
![Page 4: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/4.jpg)
Thermal MovementThermal MovementExpansion and contraction is a factor of:• Material type (steel, aluminum)• Temperature differential• Length of panels
Most specify a default of 150 deg temp. differential, unless greater is specified (COE up to 220 degrees)
Easy rule of thumb is 1/8” for every 10 ft of panel length ! (Steel panels at a 150-degree temperature change)
![Page 5: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/5.jpg)
Thermal MovementThermal Movement
![Page 6: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/6.jpg)
Thermal MovementThermal Movement
![Page 7: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/7.jpg)
Thermal Movement FormulaThermal Movement Formula
IceDam
![Page 8: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/8.jpg)
AISI Thermal Expansion ChartAISI Thermal Expansion Chart
![Page 9: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/9.jpg)
Is Thermal Design Important?Is Thermal Design Important?
Low Eave Over Expansion Oilcanning
Penetrations
![Page 10: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/10.jpg)
Thermal Movement In Other RoofingThermal Movement In Other Roofing
Modified Bitumen Roofing Asphalt Shingles
![Page 11: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/11.jpg)
Section 2: Paint Finish Testing
![Page 12: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/12.jpg)
Florida 45-Degree Paint Finish Test BedFlorida 45-Degree Paint Finish Test Bed
![Page 13: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/13.jpg)
Paint Finish Paint Finish HunterHunter Fade Units Fade Units
![Page 14: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/14.jpg)
Kynar Vs. SMP Fade RatesKynar SMP (WeatherXL)
![Page 15: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/15.jpg)
So does having a good fade rate matter?
This was a BLACK roof 5 years ago
![Page 16: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/16.jpg)
Paint Finish Delamination
![Page 17: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/17.jpg)
Paint Finish Chalking
![Page 18: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/18.jpg)
Section 3: Air, Water And Impact Testing
![Page 19: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/19.jpg)
• ASTM E-1680: test for air leakage through panels
• ASTM E-1646: tests for water penetration into the panels, simulates wind-driven rain at the panel ribs.
• UL 2281/FM 4473: impact resistance test where steel balls are dropped to simulate hailstones. “Class 4” is the best rating possible, all Alliance panels meet Class 4.
Air, Water and Impact TestingAir, Water and Impact Testing
![Page 20: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/20.jpg)
Suction
Usually 6.24 or 12.0 psf
![Page 21: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/21.jpg)
This procedure tests for water penetration into the panels, simulates wind-driven rain at the panel ribs.
ASTM E-1646 Water Penetration TestASTM E-1646 Water Penetration Test
Suction
![Page 22: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/22.jpg)
The Cool Impact Resistance TestUL Standard 2218 This test, developed and standardized in
1996, was designed for use in evaluating resistance to impact by replicating the impact energy of large hailstones on roof covering materials. The test involves dropping a series of varying sized and weighted steel balls from distances varying from 12 to 20 feet on test decks, built to replicate actual roof installations.
Micro-Cracking of the top Galvalume layer---------->
22 gauge Steel
![Page 23: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/23.jpg)
Section 4: Wind Uplift Testing
![Page 24: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/24.jpg)
Does Wind Uplift Really Effect Roofing?
![Page 25: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/25.jpg)
The Uplift Failure That Started It All
RICOWI was formed to investigate the wind uplift failures from Hurricane Katrina.
![Page 26: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/26.jpg)
RICOWI: Roofing Industry Commission On Weather Issues Established in 1990 as a non-profit organization to identify and address important technical issues related to the cause of wind damage which include:•Dynamic testing of roof systems;•Importance of sample size for tests;•Role of wind tunnels and air retarders;•Need for acceptable procedures for ballasted systems;•Field data and response team reports;•General lack of communication within the roofing industry
Main sponsor organization is Oak Ridge National Laboratory.
![Page 27: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/27.jpg)
What Came Out Of The RICOWI InvestigationsIt was determined that roofs experience different wind uplift loads depending on their size, shape, height, location and wind exposure. Engineers now have to design for three roof wind exposure zones:
![Page 28: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/28.jpg)
What Came Out Of The RICOWI InvestigationsIt was also determined that different geographical locations experience different nominal (average) wind speeds. A new wind zone design map was created:
![Page 29: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/29.jpg)
There are three industry recognized wind uplift test methods:
1. UL 580 Class 90
2. ASTM E-1592
3. Factory Mutual
Wind Uplift Test Methods
![Page 30: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/30.jpg)
UL 580 Class 90UL 580 Class 90• A measure of quality assurance only – it does
not model real world exposure!• Often incorrectly specified as a UL-90 test; it
should be described as UL 580, Class 90• A 10’ x 10’ assembly of various substrates are
subjected to incremental positive and negative pressures, both static and oscillating. Note: the test sample is fastened around the perimeter!!!
• Passing assembly must show no joint disengagement, clip distress, or buckling.
![Page 31: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/31.jpg)
UL 580 (cont’d)UL 580 (cont’d)
Quote from AISI (American Iron and Steel Institute) Design Guide:
“UL 580 doesn’t give realistic panel strength values for comparing to design wind pressures that a roof may experience on an actual building. It is considered a main field of roof simulation but due to the specimen size and lack of test restrictions to the perimeter of the test specimen, the panels behave like a pre-tensioned membrane that results in un-conservative strength results”
![Page 32: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/32.jpg)
UL 580 Class 90 Test ChamberUL 580 Class 90 Test Chamber
Pressure is applied to the top and bottom of the panels
![Page 33: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/33.jpg)
Time for a Quiz !Time for a Quiz !
What does the “90” in UL-90 stand for?
• 90 miles per hour
• 90 pounds per square foot
• The number of jobs Roger will sell this month
![Page 34: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/34.jpg)
Quiz Answer
What does the “90” in UL-90 stand for?
Nothing … it’s just their test number.
It could just as easily have been A9JX3
![Page 35: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/35.jpg)
ASTM E-1592 Uplift TestASTM E-1592 Uplift Test• Premier test method for evaluating the uplift
capacity of standing seam roof panels. Best method of evaluating real world performance.
• Specimen size varies- 10’ x 25’, various end conditions allowed (fixed, floating and open).
• Test is run until failure – this establishes the ultimate load capacity of the panel.
• Ultimate load is then reduced by safety factor. (1) test SF = 2.0, multiple tests SF can be reduced depending on test repeatability. Allowable panel load is now determined.
![Page 36: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/36.jpg)
ASTM E-1592 Test PictureASTM E-1592 Test Picture
![Page 37: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/37.jpg)
Factory Mutual (FM)Factory Mutual (FM)
• FM Global is world’s largest commercial and industrial property insurance organization.
• Applicable standard for metal roofing is FM 4471. Achieving a Class 1 rating involves tests for Combustibility, Wind Uplift, Foot Traffic, Hail, and Water Leakage.
• An FM rating does not mean the roof complies with the applicable building code or wind pressures!
• If FM is not insuring the building – why is this necessary?
![Page 38: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/38.jpg)
FM I-90 ?FM I-90 ?
Many specifiers mistakenly call for an “FM I-90” rating. (I-90 is a highway that runs through Chicago) The rating is actually designated “FM 1-90”. Clip spacings example:
UC-6 HD 16" x 24 ga (standard clip)
Rating Field spacing (in) Edge Spacing(in) Corner Spacing(in)
1-60 60 50 20
1-75 60 40 20
1-90 50 25 16
1-105 40 20 13
1-120 30 15 10
![Page 39: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/39.jpg)
Factory Mutual ExplainerFactory Mutual Explainer
• The FM uplift test is similar to ASTM E-1592, in that it is run until system failure.
• The ultimate failure load determines the classification (1-90, 1-105, etc.) where the 1-xx number is the ultimate pressure load (psf).
• Ultimate failure for metal roofing panels is typically around 1-120. For typical 1-90 spec, clip spacings would be 4 ft. in the field of the roof.
• There is a difference between FM listing, FM approved, and FM loading.
![Page 40: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/40.jpg)
Factory Mutual Test To FailureFactory Mutual Test To Failure
ALokType Panel
![Page 41: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/41.jpg)
Section 5: Fire Resistance Testing
![Page 42: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/42.jpg)
UL-790 Fire Resistance TestingUL-790 includes three test procedures: Spread of
Flame, Intermittent Flame and the Burning Brand. During all three tests, there can be no flaming or glowing wood particles falling off the underside of the test deck, the roof deck cannot become exposed, and portions of the deck must not fall or break away in the form of glowing particles.
Roof assemblies with combustible decks (plywood, plank or tongue and groove) require two additional fire tests: (1) an intermittent flame and (2) the burning brand which measures the ability to resist flaming embers.
![Page 43: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/43.jpg)
UL-790 Test Classifications
![Page 44: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/44.jpg)
UL-790 Flaming Brand Test Material
![Page 45: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/45.jpg)
UL-790 Flaming Brand Test
![Page 46: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/46.jpg)
UL-790 Fire Resistance Proof (flying embers do make a difference)
![Page 47: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/47.jpg)
Section 6: Common Metal Roof Problems
![Page 48: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/48.jpg)
Galvanic Corrosion/Dissimilar Metals
The most protective metal will sacrifice itself first – note the copper is still new.
![Page 49: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/49.jpg)
Wet Stack Staining
![Page 50: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/50.jpg)
Swarf – Rusting Metal Filings
Swarf are rusting metal filings that have landed on and melted into the paint system.
![Page 51: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/51.jpg)
Rusting
Rust is scientifically called oxidation, which occurs when oxygen comes in long-term contact with iron. Over time, the oxygen combines with the metal at an atomic level, forming a new compound called an oxide and weakening the bonds of the metal itself - it is a CORROSION problem. If the base metal is iron or steel, the resulting rust is properly called iron oxide – it is not a “sacrificial action” of the finish.
![Page 52: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/52.jpg)
Uneven Substrate - Oilcanning
![Page 53: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/53.jpg)
Improper Storage
![Page 54: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/54.jpg)
Don’t Step On The Flashings
![Page 55: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/55.jpg)
Fire Station # 4North Richland Hills, TX
Improper Design: More Pookie Didn’t Help
![Page 56: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/56.jpg)
Mechanical SeamerMechanical Seamer
Ice And Snow Is Heavy
![Page 57: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/57.jpg)
Proper “Avalanche” Valley Design
![Page 58: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/58.jpg)
Why Snow Design Is Important
Before After
![Page 59: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/59.jpg)
Why We Stock Masterflash Pipe Boots
![Page 60: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/60.jpg)
How Does The Water Get Around?
![Page 61: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/61.jpg)
Solution To A Dilemma
![Page 62: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/62.jpg)
Use Touch-Up Paint Sparingly
Most Air-Dry Touch-Up Paints Fade Within Six Months.That’s Why They Come With Little Tiny Brushes!
![Page 63: Metal Panel Product Performance Testing Seminar](https://reader035.vdocuments.us/reader035/viewer/2022070522/58ee21071a28abe01a8b45db/html5/thumbnails/63.jpg)
Thank you for your attention
Any Questions?