memwriter & doctor software - scc-service.com · troubleshooting: 1.ensure that the black...
TRANSCRIPT
![Page 1: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/1.jpg)
Installationsanleitung
MemWriter & Doctor Software
26.03.2017
Karsten Nowak
![Page 2: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/2.jpg)
PC / Laptop
USB Kabel
Adapter Div. Geräte
ggf. Zwischenadapter
Whirlpool
Internet
• Programmieren
• Re-programmieren
![Page 3: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/3.jpg)
PC / Laptop
USB Kabel
Adapter Div. Elektronik
ggf. Zwischenadapter
Whirlpool
Internet
• Programmieren
• Re-programmieren
![Page 4: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/4.jpg)
PC / Laptop
USB Kabel
Adapter Div. Geräte
ggf. Zwischenadapter
• Einzeltest
• Gesamttest
• Statistiken
![Page 5: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/5.jpg)
- unterstützte Versionen von Windows:
Windows 10
Windows 8 und 8.1
Windows 7
Windows XP mit Service Pack 2
Windows 2000 mit Service Pack 3
Windows 98
Windows 98 Second Edition
Windows ME
Windows Server 2003
- Arbeitsspeicher 96 MB RAM (Minimum), 256 MB (empfohlen)
- Auflösung 1024 x 768 high color, 32-bit
- Festplatte 50 Mb freier Speicherplatz
- Bereits vorhandene Software Microsoft .Net framework 2.0. download von:
http://www.microsoft.com/en-gb/download/details.aspx?id=1639
- Mindestens Windows Installer 3.1 download von:
http://www.microsoft.com/en-us/download/details.aspx?id=16821
- Microsoft Visual C++ 2005 Redistributable Package (x86) download von:
http://www.microsoft.com/en-us/download/confirmation.aspx?id=5638
Systemvorraussetzungen
![Page 6: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/6.jpg)
Bei Neuinstallation bitte die Reihenfolge beachten
1. Manuelles erstellen zweier benötigter Ordner
( Siehe Folgeseite )
2. Treiberinstallation
( Adapter hierbei noch nicht mit PC verbinden )
3. Doctor Softwareinstallation
4. MemWriter Softwareinstallation inkl. Konfiguration
( Dateien werden nur entpackt und verschoben )
![Page 7: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/7.jpg)
Manuelles erstellen zweier benötigter Ordner
Öffnen Sie mit dem Explorer Ihre Festplatte C:\ und erstellen Sie direkt auf dieser Ebene
manuell einen neuen Ordner und benennen Sie diesen „rfx “
Öffnen Sie den „rfx“ Ordner und erstellen Sie in diesem Ordner einen neuen Ordner welcher
als „out“ benannt werden muss.
C:\rfx
C:\rfx\out
![Page 8: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/8.jpg)
Installation des Treibers
Verbinden Sie den Adapter noch nicht mit Ihren PC, führen Sie zunächst
die Installationsdatei des Treibers aus.
PL2303_Prolific_DriverInstaller_v1417.exe
Starten Sie das Setup und führen Sie diese mit „Weiter“ / „Next“ bis zum
Ende durch.
Nach abgeschlossener Installation können Sie nun per USB-Kabel den
Adapter mit Ihrem PC verbinden. Windows wird die neue Hardware erkennen
und innerhalb weniger Sekunden automatisch den Treiber zu diesem Anschluss
verwenden.
Hinweis:
Windows wird dem USB-Port einen COM-Port zuweisen, wird der Adapter an einem anderen USB-Port
angeschlossen, wird sich der COM-Port ebenfalls ändern! Beachten Sie hierbei die Folgeseiten bei der
Verwendung des MemWriters oder Doctors!
![Page 9: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/9.jpg)
Installation der Doctor Software
Führen Sie die Installation der Doctor Software durch, öffnen Sie hierzu die
setup.exe und führen Sie mit „Weiter“ / „Next“ die Installation bin zum Ende
durch. Alle vom System verwendeten Einstellungen während der Installation
sollten nicht umgestellt oder geändert werden.
In der Software können Sie nach dem öffnen Ihre gewünschte Sprache
einstellen, weitere Konfigurationen sind hierbei nicht mehr notwendig.
Hinweis:
Die Software wird automatisch installiert, nachdem die Installation abgeschlossen wurde, befindet sich ein
neues Programmsymbol direkt auf Ihrem Desktop. Beachten Sie bitte die Verwendung der Einstellung des
COM-Ports
![Page 10: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/10.jpg)
Entpacken Sie den MemWriter*.ZIP Ordner auf einen beliebigen Ort, wir empfehlen
diesen Ordner direkt in das Verzeichnis zu verschieben indem sich bereits die
Doctor Software automatisch installiert hat.
Der Pfad heißt C:\indesit\
Öffnen Sie nachdem Sie diesen „verschoben“ haben und klicken Sie mit der rechten
Maustaste auf das u.g. Symbol, verwenden Sie „Senden an Desktop“ und auf Ihrem
Desktop wird die MemWriter Software eine korrekte Verknüpfung erstellen.
Hinweis:
Beachten Sie bitte die Verwendung der Einstellung des COM-Ports
Installation der MemWriter Software
![Page 11: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/11.jpg)
Die MemWriter Software benötigt eine wichtige Einstellung, öffnen Sie hierzu das
Menü: „COMET“, tragen Sie hier das Passwort: MEMCOM261108 ein und
klicken Sie mit der Maus auf „OK“.
Hierbei muss die Einstellung auf Server DataBase umgestellt werden und
als „Techniker Nummer“ 999999 verwendet werden, nun können sie diese
Einstellung „sichern“
Hinweis:
Wird diese Konfiguration nicht gemacht, können keine Elektroniken programmiert werden!
Konfiguration der MemWriter Software
![Page 12: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/12.jpg)
Prüfen Sie den verwendeten COM-Port
Prüfen Sie jedes mal wenn Sie den Adapter an irgendeinem USB-Port
anschließen, welcher COM-Port von Windows verwendet wurde. Wird
immer der gleiche USB-Port verwendet, bleibt der COM-Port ebenfalls
immer gleich.
1. Weg
Öffnen Sie den Gerätemanager unter Windows, hier wird ihnen der Adapter
Unter Anschlüsse (COM & LPT) angezeigt.
Beisp.
COM 10
Hinweis:
Windows wird dem USB-Port einen COM-Port zuweisen, wird der Adapter an einem anderen USB-Port
angeschlossen, wird sich der COM-Port ebenfalls ändern!
![Page 13: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/13.jpg)
Prüfen Sie den verwendeten COM-Port
Prüfen Sie jedes mal wenn Sie den Adapter an irgendeinem USB-Port
anschließen, welcher COM-Port von Windows verwendet wurde. Wird
immer der gleiche USB-Port verwendet, bleibt der COM-Port ebenfalls
immer gleich.
2. Weg
Öffnen Sie von Windows das Menü: „Geräte & Drucker“, hier wird Ihnen
der nun Vorhandene Adapter angezeigt.
Beisp.
COM 10
Hinweis:
Windows wird dem USB-Port einen COM-Port zuweisen, wird der Adapter an einem anderen USB-Port
angeschlossen, wird sich der COM-Port ebenfalls ändern!
![Page 14: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/14.jpg)
Verwendung der Doctor Software
Nach dem öffnen der Doctor Software muss in der Einstellung der entsprechende
COM-Port eingestellt werden. Nachdem der richtige COM-Port eingestellt wurde,
können Sie sich entweder direkt mit der Steuerung verbinden oder die Statistik
abrufen.
Hinweis:
Windows wird dem USB-Port einen COM-Port zuweisen, wird der Adapter an einem anderen USB-Port
angeschlossen, wird sich der COM-Port ebenfalls ändern!
![Page 15: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/15.jpg)
Verwendung der MemWriter Software
Nach dem öffnen der MemWriter Software muss in der Einstellung der entsprechende
COM-Port eingestellt werden. Nachdem der richtige COM-Port eingestellt wurde,
können Sie sich direkt mit der Steuerung verbinden.
Hinweis:
Windows wird dem USB-Port einen COM-Port zuweisen, wird der Adapter an einem anderen USB-Port
angeschlossen, wird sich der COM-Port ebenfalls ändern!
Serial / USB
Folgeseiten
Beachten! Die
Meisten Elektroniken
Werden mit dieser
Einstellung programmiert.
Nur diese Methode
verwenden!
11 stelliger Code 9 stellige S/N Auf Server suchen
COM-Port? Verbinden
oder Trennen
![Page 16: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/16.jpg)
Verwendung der MemWriter Software
Um auf den Server zugreifen zu können, benötigen Sie Ihren Account,
dieser Account ist nicht gleich wie Service NET oder WeDoc, Sie benötigen hier
einen ganz spezifischen Account! Sollten Sie diese Daten vergessen haben oder
noch keinen Account besitzen, dann wenden Sie sich an unser Backoffice.
Hinweis:
Benötigen Sie diese Daten? Wenden Sie sich an das Backoffice
[email protected] oder 0711 810 81 6111
Benutzername & Passwort
Download Software für
Elektronik
![Page 17: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/17.jpg)
Verwendung der MemWriter Software
Nachdem die Software für die Elektronik herunter geladen wurde, können
Sie diese zur Elektronik programmieren, beachten Sie die u.g. Schritte.
Hinweis:
Bestätigen Sie die Meldungen mit „OK“ / „JA“, hierbei handelt es sich nicht um Fehlermeldungen!
Elektronik verbunden mit Adapter?
- Bestätigen -
Bei Re-programmierung, Software identisch
mit der vom Server geladener?
- Bestätigen -
Software mit „Download“ zur Elektronik
„hochladen“ (Button falsch beschriftet)
![Page 18: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/18.jpg)
Verwendung der MemWriter Software
Während des programmieren wird der Prozess entsprechend angezeigt.
Hinweis:
Wird eine Fehlermeldung während des programmieren oder im Vorfeld angezeigt, beachten Sie bitte
die Folgenden Seiten.
Software wird im ersten Schritt auf die Elektronik
programmiert und im zweiten Schritt wieder zur
Kontrolle überprüft.
Nach erfolgreicher Programmierung wird
NO ERRORS angezeigt.
![Page 19: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/19.jpg)
19
Programmieren von Elektroniken außerhalb des Gerätes
Beachten Sie, dass Elektroniken erst in das Gerät verbaut und dann programmiert werden, ist
vor Ort keine direkte Verbindung mit dem Internet möglich, können Sie die Elektronik auch im
Büro, Geschäft, Werkstatt oder am Fahrzeug programmieren.
Schließen Sie hierzu direkt an der Elektronik ein Netzkabel an, ein passendes Netzkabel gibt
es unter ET-Nr. 4819 321 18136
Schuko AMP-Stecker
Wo genau die AMP-Stecker auf der jeweiligen Elektronik angeschlossen werden, entnehmen
Sie bitte den Service Quick Guides siehe Aktuelle Info Nr. 4802 720 91020
![Page 20: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/20.jpg)
20
MemWriter PC – Appendix 1 – Error Messages
ERROR DESCRIPTION: The memwriter cannot read the IDENTification TABLE of the electronic board. TROUBLESHOOTING: 1. Check that the Com port is correctly selected. 2. Ensure that the black hardware key icon (see par. 8) is being selected 3. The module may not have any firmware loaded (unable to be
programmed) 4. Check the board and/or the hardware key is properly powered 5. Check the connection between the board and the hardware key 6. Check to be within the Bluetooth range 7. Check for any communication interference (e.g.: very strong magnetic
fields, Wi-Fi interferences….) 8. Check for the integrity of the connection cables 9. Ensure that the software drivers are properly installed
![Page 21: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/21.jpg)
21
MemWriter PC – Appendix 1 – Error Messages
ERROR DESCRIPTION: The memwriter cannot communicate with the hardware key TROUBLESHOOTING: 1. Ensure that the black hardware key icon (see par. 8) is being selected 2. Check that the appliance is connected to the mains supply / the hardware
key is powered. 3. Check the connection between the board and the hardware key 4. Check to be within the Bluetooth range 5. Check for any communication interference (e.g.: very stronge magnetic
fields, Wi-Fi interferences….) 6. Check for the integrity of the connection cables
ERROR DESCRIPTION: The selected Hardware Key icon is wrong TROUBLESHOOTING: 1. Wrong hardware key icon (see par. 8) selected in
Communication Settings. Select the black hardware key setting
![Page 22: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/22.jpg)
22
MemWriter PC – Appendix 1 – Error Messages
ERROR DESCRIPTION: There was an error when the Memwriter tried to
communicate with the appliance TROUBLESHOOTING: 1. Ensure that the correct Com port is selected 2. Check that the connections (cables, plugs, connectors, ...)
are properly fixed - disconnect and re-connect several times 3. Check if there are any communication problems with the
remote assistance server 4. The setting file could not be present in the Remote
Assistance Server (please communicate to your Service Quality Manager)
ERROR DESCRIPTION: There was an error when the Memwriter tried to communicate with
the appliance TROUBLESHOOTING: Check that the user interface is not standing-by. Activate the user interface and try to re-program. (pay attention expecially to the cooking and dishwashing product).
![Page 23: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/23.jpg)
23
MemWriter PC – Appendix 1 – Error Messages
ERROR DESCRIPTION: There was an error when checking the downloaded setting file TROUBLESHOOTING: 1. Try to download the setting file again 2. Check if you are programming the correct C+8 for the intended
appliance
ERROR DESCRIPTION: There was an error when the Memwriter tried to communicate with the appliance TROUBLESHOOTING: 1. You can get this error message when trying to program an EVO I board. Just try to re-program. If the error message pops-up in the verification step, the board was correctly written anyway.
ERROR DESCRIPTION: There was an error when the Memwriter tried to communicate with the appliance TROUBLESHOOTING: 1. Check if the Eeprom is inserted before programming an EVO I or EVOII
![Page 24: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/24.jpg)
24
MemWriter PC – Appendix 1 – Error Messages
ERROR DESCRIPTION: The Com port is not open TROUBLESHOOTING 1. The Com port is closed. Open the port in Communication
Settings.
ERROR DESCRIPTION: The memwriter cannot read any data from the appliance TROUBLESHOOTING 1. Check the appliance type (i.e.: the correct electronic platform)
in Target Settings 2. Check that the appliance is connected to the mains supply /
the hardware key is powered 3. Ensure that the black hardware key icon (see par. 8) is being
selected
![Page 25: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/25.jpg)
25
MemWriter PC – Appendix 1 – Error Messages
ERROR DESCRIPTION: There was an error trying to open the COM port TROUBLESHOOTING 1. Ensure that the USB cable is connected before opening the Com port 2. Check if the correct COM port has been selected (in Menu Windows -
Control Panel - Device Manager see the COM port where the hardware key was installed (USB or Bluetooth))
ERROR DESCRIPTION: The setting file is not compatible with the electronic board TROUBLESHOOTING 1. The file to be loaded on the board is from a different electronic platform
than the firmware on the board. Check the file on the server
![Page 26: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/26.jpg)
26
MemWriter PC – Appendix 1 – Error Messages
ERROR DESCRIPTION: The MemWriter is trying to load the setting file from a local database,
but no folder was specified. TROUBLESHOOTING 1. Check that the “Server Database” in the “COMET Setup” dialog box
is checked, and that the “Local Database” is unchecked
ERROR DESCRIPTION: The downloaded setting file is not correct for the intended board TROUBLESHOOTING 1. The setting file was not properly downloaded from the server. Try
and download it again 2. A wrong platform was selected (e.g.: downloading an Arcadia file
setting on a EVO2 board). Select the correct platform (see par. 8)
![Page 27: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/27.jpg)
27
MemWriter PC – Appendix 1 – Error Messages
ERROR DESCRIPTION: There was an error when the memwriter try to erase the old setting
file (maybe an interference when the SW is going to erase). TROUBLESHOOTING 1. Disconnect the mainboard from the power alimentation for one
minute. Just try programming once again 2. Use the white HW Key. If you have bought it after 04/2014 it has
the new firmware, otherwise be sure that it has been re-flashed with the new firmware.
ERROR DESCRIPTION: The version of memwriter that is used is an old version, and doesn’t
support the intended board TROUBLESHOOTING 1. Install the last released version of memwriter and try again to
program the board.
![Page 28: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/28.jpg)
28
MemWriter PC – Appendix 1 – Error Messages
ERROR DESCRIPTION: The error message "I/O generic error" is an error message that
identifies that something went wrong during erasing or writing of the flash memory.
TROUBLESHOOTING 1. Problem during the communication with the board. Just try
programming once again. 2. The hardware key was disconnected during the downloading
causing a timeout. Just try programming once again. 3. An area of the flash memory of the board is damaged. Order
another board and try to program it.
![Page 29: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/29.jpg)
29
MemWriter PC – Appendix 2 – Web Access Error Messages
ERROR MESSAGES NOTES
Error: Connection with Indesit web site.
Check GPRS state
There was a some issues with internet connection.
Please check that the PC/PDA is actually connected to the internet. Error: Communication during the download
Check GPRS state
Check GPRS connection, if the error persist restart the
application
Be sure that telephone is on. Check that the PDA is active (ONLY PDA)
Version.txt file not present.
Install again remote assistance software. The“Version.txt “file is not present in the main directory of the software.
Reinstall the remote assistance software.
Access denied.
IMEI not registered Server communication
Server communication.
Check with the
managers of the server
that is all right.
Only if the error is C01
you need to update the
“Version.txt” file. ( this
task if not for the
engineer, ask support
to the quality)
Access denied.
UserId or Password are wrong Server communication
Server connection error C01
Server communication. Unsupported version. The installed software version
is newer than the one on the server. The password may be incorrect.
Server connection error C02 Server communication. Error in the server database
Server connection error C03 Server communication. Transaction ID with the server not valid
Setting file not prenset in the server Server communication. Setting file not prenset in the server
Server connection error C04 Server communication. Remote Assistance Software is not found on the
server
Server connection error C05 Server communication. Version not available
ATTENTION: remote assistance software version not
updated.
Install * version available in the server
Server communication. The installed software version is older than the one
on the server.
![Page 30: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/30.jpg)
30
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
Washing Machine EVO1
1.Requires eeprom 93C86 inserted before programming 2. Power supply to Hardware Key +6V 3. Memwriter Appliance Setting: WM EVO I 4. Setting file format: 28xxxxxxxxx
![Page 31: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/31.jpg)
31
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
Washing Machine EVO2 Low End
1.Requires eeprom 24C64 inserted before programming 2. Power supply to Hardware Key +6V 3. Memwriter Appliance Setting: WM EVO II / DRYER 4. Use hardware key adapter C00255979 5. Setting file format: 28xxxxxxxxx Programming connector J12
From beginning of April 2008 spare parts warehouse started to manage the EVOII modules with
eeprom fixed, these can only be programmed with smart card/palmare/pc (so modules after that
date does not need a eeprom - skip step 1).
Attention!! The premodification with eeprom socket can be programmed with smart
card/palmare/pc using a blank eeprom or with pre programmed eeprom.
![Page 32: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/32.jpg)
32
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
Washing Machine EVO2
1.Requires eeprom 24C64 inserted before programming 2. Power supply to Hardware Key +6V 3. Memwriter Appliance Setting: WM EVO II / DRYER 4. Setting file format: 28xxxxxxxxx
From beginning of April 2008 spare parts warehouse started to manage the EVOII modules with
eeprom fixed, these can only be programmed with smart card/palmare/pc (so modules after that
date does not need a eeprom - skip step 1).
Attention!! The premodification with eeprom socket can be programmed with smart
card/palmare/pc using a blank eeprom or with pre programmed eeprom.
Collector 3-Phase
Programming connector J7
![Page 33: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/33.jpg)
33
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
Tumble Dryer EVO2
1.Requires eeprom 24C64 inserted before programming 2. Power supply to Hardware Key +6V 3. Memwriter Appliance Setting: WM EVO II / DRYER 4. Setting file format: 28xxxxxxxxx
Programming connector J8
From beginning of April 2008 spare parts warehouse started to manage the EVOII modules with
eeprom fixed, these can only be programmed with smart card/palmare/pc (so modules after that
date does not need a eeprom - skip step 1).
Attention!! The premodification with eeprom socket can be programmed with smart
card/palmare/pc using a blank eeprom or with pre programmed eeprom.
![Page 34: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/34.jpg)
34
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
Dryer Entry level (Strip modul) [NEW PLATFORM]
1. No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. use hardware key adapter C00255979 5. Setting file format: 50xxxxxxxxx
Programming connector CN1
Arcadia Dryer [NEW PLATFORM]
1. No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Setting file format: 50xxxxxxxxx
Programming connector J1
CN1
J1
![Page 35: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/35.jpg)
35
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
Washing Machine ARCADIA (NEW PLATFORM)
1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Setting file format: 50xxxxxxxxx
Arcadia Full 3-Phase Programming connector J15
Arcadia Base Collector Programming connector J7
Arcadia Full Collector Programming connector J7
![Page 36: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/36.jpg)
36
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
Washing Machine ARCADIA 2 (NEW PLATFORM)
1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Setting file format: 87xxxxxxxxx
Arcadia 2 Full 3-Phase Programming connector J13 Arcadia 2 Strip 3-Phase Programming connector J13
Arcadia 2 Base Collector Programming connector J7
![Page 37: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/37.jpg)
37
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Setting file format: 28xxxxxxxxx
Dishwasher DEA 600 / DEA 601 / DEA 602 (NEW PLATFORM)
A B
C
![Page 38: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/38.jpg)
38
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Setting file format: 28xxxxxxxxx
Dishwasher DEA 700 / DEA 603 (NEW PLATFORM)
A B
C
![Page 39: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/39.jpg)
39
1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. For FULL & STRIP board use module box C00252366 for ease 5. Setting file format: 28xxxxxxxxx
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
Cooling CL 2005 / CL 2008 (NEW PLATFORM)
Full Strip
Programming connector DIRECTLY ON THE SURFACE
OF MAIN BOARD
![Page 40: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/40.jpg)
40
1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. For Static & Entry Segment use hardware key adapter C00255979 5. Setting file format: 28xxxxxxxxx
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
Cooling CL 2005 / CL 2008 (NEW PLATFORM)
Entry Segment Programming connector E3
Static Board Programming connector L4
![Page 41: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/41.jpg)
41
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
Cooling ARTICA (NEW PLATFORM) 1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. For Full & Entry Segment use hardware key adapter C00255979 and connector C00275571 4. Setting file format: FULL: 77xxxxxxxxx ENTRY: 78xxxxxxxxx
Artica entry segment
Programming connector J13
Artica full Programming connector J13
![Page 42: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/42.jpg)
42
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
Cooling ARTICA (NEW PLATFORM) 1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. For Clever use hardware key adapter C00255979 and connector C00275571 4. Setting file format: CLEVER 79xxxxxxxxx
Clever IN Programming connector CN2
Clever OUT
Programming connector CN2
To reprogram this board, disconnect
the user interface connector and
replace it with hardware key adapter
CN2
CN2
![Page 43: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/43.jpg)
43
1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Use hardware key adapter C00142028 + C00142026. 5. Setting file format: 28xxxxxxxxx
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
Cooking HOT 2005 (NEW PLATFORM)
Programming connector J7
![Page 44: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/44.jpg)
44
1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. If you program to bench, use the module support C00297766 5. Setting file format: 28xxxxxxxxx
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
Cooking HOTTIMA (NEW PLATFORM)
![Page 45: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected](https://reader031.vdocuments.us/reader031/viewer/2022012307/5c9fa30988c99312188bc030/html5/thumbnails/45.jpg)
45
1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Setting file format: 96xxxxxxxxx
MemWriter PC – Appendix 2 – Programmable Electronic Platforms
HOOD (NEW PLATFORM)