memwriter & doctor software - scc-service.com · troubleshooting: 1.ensure that the black...

45
Installationsanleitung MemWriter & Doctor Software 26.03.2017 Karsten Nowak

Upload: truongthuy

Post on 31-Mar-2019

315 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Installationsanleitung

MemWriter & Doctor Software

26.03.2017

Karsten Nowak

Page 2: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

PC / Laptop

USB Kabel

Adapter Div. Geräte

ggf. Zwischenadapter

Whirlpool

Internet

• Programmieren

• Re-programmieren

Page 3: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

PC / Laptop

USB Kabel

Adapter Div. Elektronik

ggf. Zwischenadapter

Whirlpool

Internet

• Programmieren

• Re-programmieren

Page 4: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

PC / Laptop

USB Kabel

Adapter Div. Geräte

ggf. Zwischenadapter

• Einzeltest

• Gesamttest

• Statistiken

Page 5: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

- unterstützte Versionen von Windows:

Windows 10

Windows 8 und 8.1

Windows 7

Windows XP mit Service Pack 2

Windows 2000 mit Service Pack 3

Windows 98

Windows 98 Second Edition

Windows ME

Windows Server 2003

- Arbeitsspeicher 96 MB RAM (Minimum), 256 MB (empfohlen)

- Auflösung 1024 x 768 high color, 32-bit

- Festplatte 50 Mb freier Speicherplatz

- Bereits vorhandene Software Microsoft .Net framework 2.0. download von:

http://www.microsoft.com/en-gb/download/details.aspx?id=1639

- Mindestens Windows Installer 3.1 download von:

http://www.microsoft.com/en-us/download/details.aspx?id=16821

- Microsoft Visual C++ 2005 Redistributable Package (x86) download von:

http://www.microsoft.com/en-us/download/confirmation.aspx?id=5638

Systemvorraussetzungen

Page 6: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Bei Neuinstallation bitte die Reihenfolge beachten

1. Manuelles erstellen zweier benötigter Ordner

( Siehe Folgeseite )

2. Treiberinstallation

( Adapter hierbei noch nicht mit PC verbinden )

3. Doctor Softwareinstallation

4. MemWriter Softwareinstallation inkl. Konfiguration

( Dateien werden nur entpackt und verschoben )

Page 7: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Manuelles erstellen zweier benötigter Ordner

Öffnen Sie mit dem Explorer Ihre Festplatte C:\ und erstellen Sie direkt auf dieser Ebene

manuell einen neuen Ordner und benennen Sie diesen „rfx “

Öffnen Sie den „rfx“ Ordner und erstellen Sie in diesem Ordner einen neuen Ordner welcher

als „out“ benannt werden muss.

C:\rfx

C:\rfx\out

Page 8: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Installation des Treibers

Verbinden Sie den Adapter noch nicht mit Ihren PC, führen Sie zunächst

die Installationsdatei des Treibers aus.

PL2303_Prolific_DriverInstaller_v1417.exe

Starten Sie das Setup und führen Sie diese mit „Weiter“ / „Next“ bis zum

Ende durch.

Nach abgeschlossener Installation können Sie nun per USB-Kabel den

Adapter mit Ihrem PC verbinden. Windows wird die neue Hardware erkennen

und innerhalb weniger Sekunden automatisch den Treiber zu diesem Anschluss

verwenden.

Hinweis:

Windows wird dem USB-Port einen COM-Port zuweisen, wird der Adapter an einem anderen USB-Port

angeschlossen, wird sich der COM-Port ebenfalls ändern! Beachten Sie hierbei die Folgeseiten bei der

Verwendung des MemWriters oder Doctors!

Page 9: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Installation der Doctor Software

Führen Sie die Installation der Doctor Software durch, öffnen Sie hierzu die

setup.exe und führen Sie mit „Weiter“ / „Next“ die Installation bin zum Ende

durch. Alle vom System verwendeten Einstellungen während der Installation

sollten nicht umgestellt oder geändert werden.

In der Software können Sie nach dem öffnen Ihre gewünschte Sprache

einstellen, weitere Konfigurationen sind hierbei nicht mehr notwendig.

Hinweis:

Die Software wird automatisch installiert, nachdem die Installation abgeschlossen wurde, befindet sich ein

neues Programmsymbol direkt auf Ihrem Desktop. Beachten Sie bitte die Verwendung der Einstellung des

COM-Ports

Page 10: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Entpacken Sie den MemWriter*.ZIP Ordner auf einen beliebigen Ort, wir empfehlen

diesen Ordner direkt in das Verzeichnis zu verschieben indem sich bereits die

Doctor Software automatisch installiert hat.

Der Pfad heißt C:\indesit\

Öffnen Sie nachdem Sie diesen „verschoben“ haben und klicken Sie mit der rechten

Maustaste auf das u.g. Symbol, verwenden Sie „Senden an Desktop“ und auf Ihrem

Desktop wird die MemWriter Software eine korrekte Verknüpfung erstellen.

Hinweis:

Beachten Sie bitte die Verwendung der Einstellung des COM-Ports

Installation der MemWriter Software

Page 11: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Die MemWriter Software benötigt eine wichtige Einstellung, öffnen Sie hierzu das

Menü: „COMET“, tragen Sie hier das Passwort: MEMCOM261108 ein und

klicken Sie mit der Maus auf „OK“.

Hierbei muss die Einstellung auf Server DataBase umgestellt werden und

als „Techniker Nummer“ 999999 verwendet werden, nun können sie diese

Einstellung „sichern“

Hinweis:

Wird diese Konfiguration nicht gemacht, können keine Elektroniken programmiert werden!

Konfiguration der MemWriter Software

Page 12: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Prüfen Sie den verwendeten COM-Port

Prüfen Sie jedes mal wenn Sie den Adapter an irgendeinem USB-Port

anschließen, welcher COM-Port von Windows verwendet wurde. Wird

immer der gleiche USB-Port verwendet, bleibt der COM-Port ebenfalls

immer gleich.

1. Weg

Öffnen Sie den Gerätemanager unter Windows, hier wird ihnen der Adapter

Unter Anschlüsse (COM & LPT) angezeigt.

Beisp.

COM 10

Hinweis:

Windows wird dem USB-Port einen COM-Port zuweisen, wird der Adapter an einem anderen USB-Port

angeschlossen, wird sich der COM-Port ebenfalls ändern!

Page 13: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Prüfen Sie den verwendeten COM-Port

Prüfen Sie jedes mal wenn Sie den Adapter an irgendeinem USB-Port

anschließen, welcher COM-Port von Windows verwendet wurde. Wird

immer der gleiche USB-Port verwendet, bleibt der COM-Port ebenfalls

immer gleich.

2. Weg

Öffnen Sie von Windows das Menü: „Geräte & Drucker“, hier wird Ihnen

der nun Vorhandene Adapter angezeigt.

Beisp.

COM 10

Hinweis:

Windows wird dem USB-Port einen COM-Port zuweisen, wird der Adapter an einem anderen USB-Port

angeschlossen, wird sich der COM-Port ebenfalls ändern!

Page 14: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Verwendung der Doctor Software

Nach dem öffnen der Doctor Software muss in der Einstellung der entsprechende

COM-Port eingestellt werden. Nachdem der richtige COM-Port eingestellt wurde,

können Sie sich entweder direkt mit der Steuerung verbinden oder die Statistik

abrufen.

Hinweis:

Windows wird dem USB-Port einen COM-Port zuweisen, wird der Adapter an einem anderen USB-Port

angeschlossen, wird sich der COM-Port ebenfalls ändern!

Page 15: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Verwendung der MemWriter Software

Nach dem öffnen der MemWriter Software muss in der Einstellung der entsprechende

COM-Port eingestellt werden. Nachdem der richtige COM-Port eingestellt wurde,

können Sie sich direkt mit der Steuerung verbinden.

Hinweis:

Windows wird dem USB-Port einen COM-Port zuweisen, wird der Adapter an einem anderen USB-Port

angeschlossen, wird sich der COM-Port ebenfalls ändern!

Serial / USB

Folgeseiten

Beachten! Die

Meisten Elektroniken

Werden mit dieser

Einstellung programmiert.

Nur diese Methode

verwenden!

11 stelliger Code 9 stellige S/N Auf Server suchen

COM-Port? Verbinden

oder Trennen

Page 16: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Verwendung der MemWriter Software

Um auf den Server zugreifen zu können, benötigen Sie Ihren Account,

dieser Account ist nicht gleich wie Service NET oder WeDoc, Sie benötigen hier

einen ganz spezifischen Account! Sollten Sie diese Daten vergessen haben oder

noch keinen Account besitzen, dann wenden Sie sich an unser Backoffice.

Hinweis:

Benötigen Sie diese Daten? Wenden Sie sich an das Backoffice

[email protected] oder 0711 810 81 6111

Benutzername & Passwort

Download Software für

Elektronik

Page 17: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Verwendung der MemWriter Software

Nachdem die Software für die Elektronik herunter geladen wurde, können

Sie diese zur Elektronik programmieren, beachten Sie die u.g. Schritte.

Hinweis:

Bestätigen Sie die Meldungen mit „OK“ / „JA“, hierbei handelt es sich nicht um Fehlermeldungen!

Elektronik verbunden mit Adapter?

- Bestätigen -

Bei Re-programmierung, Software identisch

mit der vom Server geladener?

- Bestätigen -

Software mit „Download“ zur Elektronik

„hochladen“ (Button falsch beschriftet)

Page 18: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

Verwendung der MemWriter Software

Während des programmieren wird der Prozess entsprechend angezeigt.

Hinweis:

Wird eine Fehlermeldung während des programmieren oder im Vorfeld angezeigt, beachten Sie bitte

die Folgenden Seiten.

Software wird im ersten Schritt auf die Elektronik

programmiert und im zweiten Schritt wieder zur

Kontrolle überprüft.

Nach erfolgreicher Programmierung wird

NO ERRORS angezeigt.

Page 19: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

19

Programmieren von Elektroniken außerhalb des Gerätes

Beachten Sie, dass Elektroniken erst in das Gerät verbaut und dann programmiert werden, ist

vor Ort keine direkte Verbindung mit dem Internet möglich, können Sie die Elektronik auch im

Büro, Geschäft, Werkstatt oder am Fahrzeug programmieren.

Schließen Sie hierzu direkt an der Elektronik ein Netzkabel an, ein passendes Netzkabel gibt

es unter ET-Nr. 4819 321 18136

Schuko AMP-Stecker

Wo genau die AMP-Stecker auf der jeweiligen Elektronik angeschlossen werden, entnehmen

Sie bitte den Service Quick Guides siehe Aktuelle Info Nr. 4802 720 91020

Page 20: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

20

MemWriter PC – Appendix 1 – Error Messages

ERROR DESCRIPTION: The memwriter cannot read the IDENTification TABLE of the electronic board. TROUBLESHOOTING: 1. Check that the Com port is correctly selected. 2. Ensure that the black hardware key icon (see par. 8) is being selected 3. The module may not have any firmware loaded (unable to be

programmed) 4. Check the board and/or the hardware key is properly powered 5. Check the connection between the board and the hardware key 6. Check to be within the Bluetooth range 7. Check for any communication interference (e.g.: very strong magnetic

fields, Wi-Fi interferences….) 8. Check for the integrity of the connection cables 9. Ensure that the software drivers are properly installed

Page 21: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

21

MemWriter PC – Appendix 1 – Error Messages

ERROR DESCRIPTION: The memwriter cannot communicate with the hardware key TROUBLESHOOTING: 1. Ensure that the black hardware key icon (see par. 8) is being selected 2. Check that the appliance is connected to the mains supply / the hardware

key is powered. 3. Check the connection between the board and the hardware key 4. Check to be within the Bluetooth range 5. Check for any communication interference (e.g.: very stronge magnetic

fields, Wi-Fi interferences….) 6. Check for the integrity of the connection cables

ERROR DESCRIPTION: The selected Hardware Key icon is wrong TROUBLESHOOTING: 1. Wrong hardware key icon (see par. 8) selected in

Communication Settings. Select the black hardware key setting

Page 22: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

22

MemWriter PC – Appendix 1 – Error Messages

ERROR DESCRIPTION: There was an error when the Memwriter tried to

communicate with the appliance TROUBLESHOOTING: 1. Ensure that the correct Com port is selected 2. Check that the connections (cables, plugs, connectors, ...)

are properly fixed - disconnect and re-connect several times 3. Check if there are any communication problems with the

remote assistance server 4. The setting file could not be present in the Remote

Assistance Server (please communicate to your Service Quality Manager)

ERROR DESCRIPTION: There was an error when the Memwriter tried to communicate with

the appliance TROUBLESHOOTING: Check that the user interface is not standing-by. Activate the user interface and try to re-program. (pay attention expecially to the cooking and dishwashing product).

Page 23: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

23

MemWriter PC – Appendix 1 – Error Messages

ERROR DESCRIPTION: There was an error when checking the downloaded setting file TROUBLESHOOTING: 1. Try to download the setting file again 2. Check if you are programming the correct C+8 for the intended

appliance

ERROR DESCRIPTION: There was an error when the Memwriter tried to communicate with the appliance TROUBLESHOOTING: 1. You can get this error message when trying to program an EVO I board. Just try to re-program. If the error message pops-up in the verification step, the board was correctly written anyway.

ERROR DESCRIPTION: There was an error when the Memwriter tried to communicate with the appliance TROUBLESHOOTING: 1. Check if the Eeprom is inserted before programming an EVO I or EVOII

Page 24: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

24

MemWriter PC – Appendix 1 – Error Messages

ERROR DESCRIPTION: The Com port is not open TROUBLESHOOTING 1. The Com port is closed. Open the port in Communication

Settings.

ERROR DESCRIPTION: The memwriter cannot read any data from the appliance TROUBLESHOOTING 1. Check the appliance type (i.e.: the correct electronic platform)

in Target Settings 2. Check that the appliance is connected to the mains supply /

the hardware key is powered 3. Ensure that the black hardware key icon (see par. 8) is being

selected

Page 25: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

25

MemWriter PC – Appendix 1 – Error Messages

ERROR DESCRIPTION: There was an error trying to open the COM port TROUBLESHOOTING 1. Ensure that the USB cable is connected before opening the Com port 2. Check if the correct COM port has been selected (in Menu Windows -

Control Panel - Device Manager see the COM port where the hardware key was installed (USB or Bluetooth))

ERROR DESCRIPTION: The setting file is not compatible with the electronic board TROUBLESHOOTING 1. The file to be loaded on the board is from a different electronic platform

than the firmware on the board. Check the file on the server

Page 26: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

26

MemWriter PC – Appendix 1 – Error Messages

ERROR DESCRIPTION: The MemWriter is trying to load the setting file from a local database,

but no folder was specified. TROUBLESHOOTING 1. Check that the “Server Database” in the “COMET Setup” dialog box

is checked, and that the “Local Database” is unchecked

ERROR DESCRIPTION: The downloaded setting file is not correct for the intended board TROUBLESHOOTING 1. The setting file was not properly downloaded from the server. Try

and download it again 2. A wrong platform was selected (e.g.: downloading an Arcadia file

setting on a EVO2 board). Select the correct platform (see par. 8)

Page 27: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

27

MemWriter PC – Appendix 1 – Error Messages

ERROR DESCRIPTION: There was an error when the memwriter try to erase the old setting

file (maybe an interference when the SW is going to erase). TROUBLESHOOTING 1. Disconnect the mainboard from the power alimentation for one

minute. Just try programming once again 2. Use the white HW Key. If you have bought it after 04/2014 it has

the new firmware, otherwise be sure that it has been re-flashed with the new firmware.

ERROR DESCRIPTION: The version of memwriter that is used is an old version, and doesn’t

support the intended board TROUBLESHOOTING 1. Install the last released version of memwriter and try again to

program the board.

Page 28: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

28

MemWriter PC – Appendix 1 – Error Messages

ERROR DESCRIPTION: The error message "I/O generic error" is an error message that

identifies that something went wrong during erasing or writing of the flash memory.

TROUBLESHOOTING 1. Problem during the communication with the board. Just try

programming once again. 2. The hardware key was disconnected during the downloading

causing a timeout. Just try programming once again. 3. An area of the flash memory of the board is damaged. Order

another board and try to program it.

Page 29: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

29

MemWriter PC – Appendix 2 – Web Access Error Messages

ERROR MESSAGES NOTES

Error: Connection with Indesit web site.

Check GPRS state

There was a some issues with internet connection.

Please check that the PC/PDA is actually connected to the internet. Error: Communication during the download

Check GPRS state

Check GPRS connection, if the error persist restart the

application

Be sure that telephone is on. Check that the PDA is active (ONLY PDA)

Version.txt file not present.

Install again remote assistance software. The“Version.txt “file is not present in the main directory of the software.

Reinstall the remote assistance software.

Access denied.

IMEI not registered Server communication

Server communication.

Check with the

managers of the server

that is all right.

Only if the error is C01

you need to update the

“Version.txt” file. ( this

task if not for the

engineer, ask support

to the quality)

Access denied.

UserId or Password are wrong Server communication

Server connection error C01

Server communication. Unsupported version. The installed software version

is newer than the one on the server. The password may be incorrect.

Server connection error C02 Server communication. Error in the server database

Server connection error C03 Server communication. Transaction ID with the server not valid

Setting file not prenset in the server Server communication. Setting file not prenset in the server

Server connection error C04 Server communication. Remote Assistance Software is not found on the

server

Server connection error C05 Server communication. Version not available

ATTENTION: remote assistance software version not

updated.

Install * version available in the server

Server communication. The installed software version is older than the one

on the server.

Page 30: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

30

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

Washing Machine EVO1

1.Requires eeprom 93C86 inserted before programming 2. Power supply to Hardware Key +6V 3. Memwriter Appliance Setting: WM EVO I 4. Setting file format: 28xxxxxxxxx

Page 31: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

31

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

Washing Machine EVO2 Low End

1.Requires eeprom 24C64 inserted before programming 2. Power supply to Hardware Key +6V 3. Memwriter Appliance Setting: WM EVO II / DRYER 4. Use hardware key adapter C00255979 5. Setting file format: 28xxxxxxxxx Programming connector J12

From beginning of April 2008 spare parts warehouse started to manage the EVOII modules with

eeprom fixed, these can only be programmed with smart card/palmare/pc (so modules after that

date does not need a eeprom - skip step 1).

Attention!! The premodification with eeprom socket can be programmed with smart

card/palmare/pc using a blank eeprom or with pre programmed eeprom.

Page 32: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

32

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

Washing Machine EVO2

1.Requires eeprom 24C64 inserted before programming 2. Power supply to Hardware Key +6V 3. Memwriter Appliance Setting: WM EVO II / DRYER 4. Setting file format: 28xxxxxxxxx

From beginning of April 2008 spare parts warehouse started to manage the EVOII modules with

eeprom fixed, these can only be programmed with smart card/palmare/pc (so modules after that

date does not need a eeprom - skip step 1).

Attention!! The premodification with eeprom socket can be programmed with smart

card/palmare/pc using a blank eeprom or with pre programmed eeprom.

Collector 3-Phase

Programming connector J7

Page 33: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

33

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

Tumble Dryer EVO2

1.Requires eeprom 24C64 inserted before programming 2. Power supply to Hardware Key +6V 3. Memwriter Appliance Setting: WM EVO II / DRYER 4. Setting file format: 28xxxxxxxxx

Programming connector J8

From beginning of April 2008 spare parts warehouse started to manage the EVOII modules with

eeprom fixed, these can only be programmed with smart card/palmare/pc (so modules after that

date does not need a eeprom - skip step 1).

Attention!! The premodification with eeprom socket can be programmed with smart

card/palmare/pc using a blank eeprom or with pre programmed eeprom.

Page 34: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

34

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

Dryer Entry level (Strip modul) [NEW PLATFORM]

1. No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. use hardware key adapter C00255979 5. Setting file format: 50xxxxxxxxx

Programming connector CN1

Arcadia Dryer [NEW PLATFORM]

1. No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Setting file format: 50xxxxxxxxx

Programming connector J1

CN1

J1

Page 35: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

35

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

Washing Machine ARCADIA (NEW PLATFORM)

1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Setting file format: 50xxxxxxxxx

Arcadia Full 3-Phase Programming connector J15

Arcadia Base Collector Programming connector J7

Arcadia Full Collector Programming connector J7

Page 36: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

36

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

Washing Machine ARCADIA 2 (NEW PLATFORM)

1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Setting file format: 87xxxxxxxxx

Arcadia 2 Full 3-Phase Programming connector J13 Arcadia 2 Strip 3-Phase Programming connector J13

Arcadia 2 Base Collector Programming connector J7

Page 37: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

37

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Setting file format: 28xxxxxxxxx

Dishwasher DEA 600 / DEA 601 / DEA 602 (NEW PLATFORM)

A B

C

Page 38: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

38

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Setting file format: 28xxxxxxxxx

Dishwasher DEA 700 / DEA 603 (NEW PLATFORM)

A B

C

Page 39: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

39

1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. For FULL & STRIP board use module box C00252366 for ease 5. Setting file format: 28xxxxxxxxx

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

Cooling CL 2005 / CL 2008 (NEW PLATFORM)

Full Strip

Programming connector DIRECTLY ON THE SURFACE

OF MAIN BOARD

Page 40: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

40

1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. For Static & Entry Segment use hardware key adapter C00255979 5. Setting file format: 28xxxxxxxxx

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

Cooling CL 2005 / CL 2008 (NEW PLATFORM)

Entry Segment Programming connector E3

Static Board Programming connector L4

Page 41: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

41

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

Cooling ARTICA (NEW PLATFORM) 1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. For Full & Entry Segment use hardware key adapter C00255979 and connector C00275571 4. Setting file format: FULL: 77xxxxxxxxx ENTRY: 78xxxxxxxxx

Artica entry segment

Programming connector J13

Artica full Programming connector J13

Page 42: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

42

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

Cooling ARTICA (NEW PLATFORM) 1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. For Clever use hardware key adapter C00255979 and connector C00275571 4. Setting file format: CLEVER 79xxxxxxxxx

Clever IN Programming connector CN2

Clever OUT

Programming connector CN2

To reprogram this board, disconnect

the user interface connector and

replace it with hardware key adapter

CN2

CN2

Page 43: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

43

1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Use hardware key adapter C00142028 + C00142026. 5. Setting file format: 28xxxxxxxxx

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

Cooking HOT 2005 (NEW PLATFORM)

Programming connector J7

Page 44: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

44

1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. If you program to bench, use the module support C00297766 5. Setting file format: 28xxxxxxxxx

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

Cooking HOTTIMA (NEW PLATFORM)

Page 45: MemWriter & Doctor Software - scc-service.com · troubleshooting: 1.Ensure that the black hardware key icon (see par. 8) is being selected 2.Check that the appliance is connected

45

1.No eeprom insertion required 2. Power supply to Hardware Key +12V 3. Memwriter Appliance Setting: NEW PLATFORM 4. Setting file format: 96xxxxxxxxx

MemWriter PC – Appendix 2 – Programmable Electronic Platforms

HOOD (NEW PLATFORM)