August 2007 CA08101001E For more information visit: www.eaton.com 5-55 Group Metering & Meter Breakers 5 Meter Breakers Residential Meets EUSERC Requirements Service Entrance Devices 100 – 225 Amperes Meets EUSERC Requirements Service Entrance Devices 100 – 225 Amperes Product Description Eaton is proud to introduce a new line of Cutler-Hammer West Coast/EUSERC Meter Breaker units. The new EUSERC devices complement the existing standard meter breaker devices. Customers who are interested in the complete meter breaker line of prod- ucts can refer to Technical Data TD.31F.01.T.E Features, Benefits and Functions Single-phase, 3-wire, 120/240 volt, 10,000 AIC. Larger 300 kcmil lugs and additional knockouts for ease of installation. Box type main lugs are included. Factory installed neutrals. Hub provisions on top endwall. If hubs are required, order “DS” type hubs. Ring type sockets are provided with a sealing ring. Padlockable device covers provide an additional measure of security, and help prevent tampering. Most units have center keyhole for easy one-person installation. Clip-Tight socket has reduced con- nections. This offers fewer hot spots and improves socket integrity. NEMA 3R rainproof construction. Product Selection Table 5-47. Catalog Numbering System (Applies to New Designs Only) MBE 20 40 B 200 B S Meter Breaker Type MB = 1-Inch (25.4 mm) BR Type MBE = 1-Inch (25.4 mm) BR Type — EUSERC CMB = .75-Inch (19.1 mm) CH Type CMBE = .75-Inch (19.1 mm) CH Type — EUSERC MBED = 7-Inch (177.8 mm) Deep MBER = 1-Inch (25.4 mm) BR Type — EUSERC Ranch CMBER = .75-inch (19.1 mm) CH Type — EUSERC Ranch MBEB = 1-Inch (25.4 mm) BR Type Back-to-Back Main B = Main Breaker Included P = Provision for Main L = Main Lug Poles Maximum Number of Poles Spacing Number of Spaces Mounting S = Surface F = Flush/Stucco Breaker Feed BT = Bottom and Top B = Bottom Only T = Top Only Amperes Amperage of Unit Accessories/Modifications D = 5th Jaw and Horn Bypass CU = Copper C = Single Cover Compact Design CR = 2 Cover Compact Design

Upload: ngohanh

Post on 26-Dec-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

CA08101001E For more information visit: www.eaton.com

5-55Group Metering & Meter Breakers

5

Meter BreakersResidential

Meets EUSERC Requirements Service Entrance Devices 100 – 225 Amperes

Meets EUSERC Requirements Service Entrance Devices 100 – 225 Amperes

Product DescriptionEaton is proud to introduce a new line of Cutler-Hammer West Coast/EUSERC Meter Breaker units. The new EUSERC devices complement the existing standard meter breaker devices. Customers who are interested in the complete meter breaker line of prod-ucts can refer to Technical Data TD.31F.01.T.E

Features, Benefits and Functions■ Single-phase, 3-wire, 120/240 volt,

10,000 AIC.■ Larger 300 kcmil lugs and additional

knockouts for ease of installation.■ Box type main lugs are included.■ Factory installed neutrals.■ Hub provisions on top endwall.

If hubs are required, order “DS” type hubs.

■ Ring type sockets are provided with a sealing ring.

■ Padlockable device covers provide an additional measure of security, and help prevent tampering.

■ Most units have center keyhole for easy one-person installation.

■ Clip-Tight� socket has reduced con-nections. This offers fewer hot spots and improves socket integrity.

■ NEMA 3R rainproof construction.

Product SelectionTable 5-47. Catalog Numbering System (Applies to New Designs Only)

MBE 20 40 B 200 B S

Meter Breaker Type

MB = 1-Inch (25.4 mm) BR Type MBE = 1-Inch (25.4 mm) BR Type —

EUSERCCMB = .75-Inch (19.1 mm) CH Type

CMBE = .75-Inch (19.1 mm) CH Type — EUSERC

MBED = 7-Inch (177.8 mm) DeepMBER = 1-Inch (25.4 mm) BR Type —

EUSERC RanchCMBER = .75-inch (19.1 mm) CH Type —

EUSERC RanchMBEB = 1-Inch (25.4 mm) BR Type

Back-to-Back

Main

B = Main Breaker IncludedP = Provision for MainL = Main Lug

Poles

Maximum Number of Poles

Spacing

Number of Spaces

Mounting

S = SurfaceF = Flush/Stucco

Breaker Feed

BT = Bottom and TopB = Bottom OnlyT = Top Only

Amperes

Amperage of Unit

Accessories/Modifications

D = 5th Jaw and Horn BypassCU = Copper

C = Single Cover Compact DesignCR = 2 Cover Compact Design

Page 2: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

5-56

For more information visit: www.eaton.com CA08101001E

Group Metering & Meter Breakers

5

Meter BreakersResidential

Product SelectionTable 5-48. Combination Service Entrance Devices — Non-EUSERC

� See Page 5-65 for box details.� See drawings for hub information knockout.� Per installed main breaker rating.� Provision for main is provided. WMB style devices accept Main Breaker style BR, 2-Pole. � When a provision for main is provided, order one of the main breakers listed in Table 5-49. Panels are dual labeled to accept Types BW or CSR Main Breakers.� MCBK225 lug kit is needed for load side cable connection for Meter Mains. Please order separately.� When a provision for main is provided, order one of the main breakers listed in this table. Panels are labeled to accept Type CSR Main Breakers. Panels are specifically designed for the Georgia Power Service Territory, but may be used in any service territory that has the same design requirements. Copper bus.� One-piece cover on utility side, Florida approved.� Single cover design.� Xcel approved.

AmpereRating

Bypass Service kAIC Jaws Distribution Main BranchBreakerType

Dimensions & EnclosureShape �

Figure Numbers Catalog Number

PriceU.S. $Wiring Knockout

Ring Style Meter Mains (no distribution section included)100150150

NoneNoneNone

OHOH/UGOH/UG

1022

444

NoneNoneNone

Provision �CSH2150CSH2150

NoneNoneNone

813 3

—5-955-59

—5-1135-103

WMB102RNMBB150BTSCR

CMBB150BTS �

200200200

NoneNoneNone

OH/UGOH/UGOH/UG

10�

22

444

NoneNoneNone

CSH2200Provision ��

CSH2200

NoneNoneNone

13 3 3

5-955-595-59

5-1135-1035-103

MBB200BTSCR

CMBP200BTS �

CMBB200BTS �

Ringless Meter Mains (no distribution section included)150200200

NoneNoneNone

OH/UGOH/UGOH/UG

101010

444

NoneNoneNone

CSH2150CSH2200CSH2200

NoneNoneNone

13 913

5-955-965-95

5-1135-1125-113

MBB150BTSC �

MBB200BTS �

MBB200BTSC �

150200200200

NoneNoneHornHorn

OH/UGOH/UGOH/UGOH/UG

10�

4455

NoneNoneNoneNone

CSH2125Provision �Provision ��

Provision ��

NoneNoneNoneNone

9 911 9

5-965-965-965-96

5-1125-1125-1125-112

MBB150BTSMBP200BTS �

MBP200SD �

MBP200BTSD

100150200

HornHornHorn

OH/UGOH/UGOH/UG

101010

555

NoneNoneNone

ProvisionBWH2150BWH2200

NoneNoneNone

151616

———

5-1145-1155-115

CHMMB100BTSCHMMB150BTSCHMMB200BTS

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD

Page 3: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

CA08101001E For more information visit: www.eaton.com

5-57Group Metering & Meter Breakers

5

Meter BreakersResidential

Product SelectionTable 5-48. Combination Service Entrance Devices — Non-EUSERC (Continued)

� See Page 5-65 for box details.� See knockout drawings for hub information.� Per installed main breaker rating.� Will accept maximum four 1-pole, two 2-pole, or two quad breakers.� When a provision for main is provided, order one of the main breakers

listed in Table 5-49. All panels are dual labeled to accept Types BW or CSR Main Breakers.

� Copper bus.� One-piece cover on utility side, Florida approved. Units come with feed-through lugs. Xcel approved.

Table 5-49. Main Breaker Selection Chart

� When a provision for main is provided, order one of the main breakers listed in this table. All panels are dual labeled to accept Types BW, BWH and CSR Main Breakers.

AmpereRating

Bypass Service kAIC Jaws Distribution Main BranchBreakerType

Dimensions & EnclosureShape �

Figure Numbers Catalog Number

PriceU.S. $Wiring Knockout

Ring Style All-in-Ones (includes distribution section)125125150

NoneNoneNone

OH/UGOH/UGOH/UG

22

444

2/4 8

None — Refer to DistributionCSH2150

BRCHCH

1 2 3

5-615-60

—5-1035-103

WMB1224SCNCMB24L125BTS ��

CMB88B150BTS ��

200200200

NoneNoneNone

OH/UGOH/UGUG

102222

444

4/8 832/42

BWH2200CSH2200CSH2200

BRCHCH

3 3 7

5-735-605-56

5-1035-1035-101

MB48B200BTS �

CMB88B200BTS ��

CMB3242B200BS ��

200 None OH/UG 22 — 42/42 — CH — — — CMB4242B200BTS �

Ringless All-in-Ones (includes distribution section)125150150

NoneNoneHorn

OH/UGOH/UGOH/UG

222210

445

4/8 4/8 8/16

BWH2125BWH2150BW2150

BRBRBR

212111

—5-90—

5-1115-111—

MBT48B125BTSMBT48B150BTSMB816B150STD

150200200

HornNoneNone

OH/UGOH/UGOH/UG

101010

544

20/40 8/16 8/16

BW2150BWH2200BWH2200

BRBRBR

111010

5-985-975-97

5-1125-1125-112

MB2040B150SD

MB816B200BTS �

MB816B200BTSCU ��

200200200

HornNoneNone

OH/UGOH/UGOH/UG

10�

544

8/16 8/16 8/16

BW2200Provision �Provision �

BRBRBR

111010

—5-975-97

—5-1125-112

MB816B200STD

MB816P200BTS �

MB816P200BTSCU ��

200200200

HornHornNone

OH/UGOH/UGOH/UG

10

554

8/16 8/1612/12

Provision �Provision �CSH2200

BRBRCH

111010

5-975-975-81

5-1125-1125-105

MB816P200STD

MB816P200BTSD

CMB1212B200BTS ��

200200200

NoneNoneNone

OH/UGOH/UGOH/UG

444

6 – 2 Pole12/126 – 2 Pole

Main LugsProvision �Main Lugs

CHCHBR

910 9

5-845-815-82

5-1055-1055-105

CMB1212L200BTS �

CMB1212P200BTS ��

MB1212L200BTS

200200200

NoneNoneNone

OH/UGOH/UGOH/UG

222210

444

24/2424/3620/40

CSH2200CSH2200BWH2200

CHCHBR

101010

5-835-895-98

5-1135-1135-112

CMB2424B200BTS ��

CMB2436B200BTS �

MB2040B200BTS �

200200200

NoneHornHorn

OH/UGOH/UGOH/UG

10

455

20/4020/4020/40

Provision �Provision �BWH2200

BRBRBR

101110

5-985-985-98

5-1125-1125-112

MB2040P200BTS �

MB2040P200SD

MB2040B200SD

200200200

LeverLeverLever

OH/UGOH/UGOH/UG

101010

555

None12/1232/42

CSH2200CSH2200CSH2200

NoneCHCH

141414

5-915-935-92

5-1085-1085-108

CMBXB200BTS �

CMBX1212B200BTS �

CMBX3242B200BTS �

200200200

LeverLeverLever

OH/UGOH/UGOH/UG

101010

555

None12/1232/42

ProvisionProvisionProvision

NoneCHCH

141414

5-915-935-92

5-1085-1085-108

CMBXP200BTS �

CMBX1212P200BTS �

CMBX3242P200BTS �

200200

NoneNone

OH/UGOH/UG

2244

4/8 4/8

ProvisionBWH2200

BRBR

2121

5-905-90

5-1115-111

MBT48P200BTS

MBT48B200BTS

MaximumAmpereRating

2-Pole Breaker Catalog Numbers

10 kAIC PriceU.S. $

22 kAIC PriceU.S. $

22 kAIC PriceU.S. $

100125150200

BW2100BW2125BW2150BW2200

BWH2100BWH2125BWH2150BWH2200

CSR2100NCSR2125NCSR2150NCSR2200N

Load Side Lug Kit for BW and CSR Breakers � MCBK225

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 22CD

Page 4: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

5-58

For more information visit: www.eaton.com CA08101001E

Group Metering & Meter Breakers

5

Meter BreakersResidential

Table 5-50. Combination Service Entrance Devices (EUSERC)

� See Table 5-57 on Page 5-65 for box details.� See knockout drawings for hub information.� Interrupting rating is dependent on the main breaker that is installed.� Unit has copper bus.� Units come with feed-through lugs.� When a provision for main is provided, order one of the main breakers

listed in Table 5-51. All panels are dual labeled to accept Types BW or CSR Main Breakers.

� Please use RH-Type hubs on top end wall for overhead feed. Includes factory mounted 2.50 inch hub on bottom endwall.

UG feed only. Semi flush flange, not full stucco flange.� Units include a 2-pole provision for secondary main 70 A max. Type

BR, BRH, BRHH.

Table 5-51. Main Breaker Selection Chart

� When a provision for main is provided, order one of the main breakers listed in this table. All panels are dual labeled to accept Types BW, BWH and CSR Main Breakers.

Amp.Rating

By-pass

Service kAIC Jaws Distri-bution

Main BranchBreakerType

Dimen-sions &EnclosureShape �

Figure Numbers Catalog Number

Wir-ing

Knock-out �

Surface PriceU.S. $

Flush PriceU.S. $

Ring Style Meter Mains (no distribution section included)125125

NoneNone

OH/UGOH/UG

�44

2/4 2/4

MLOMLO

BRCH

2 2

5-715-61

5-103, 5-1025-103

MBE24L125BTSCMBE24L125BTS �

MBE24L125BTF—

150200200

NoneNoneNone

OH/UGOH/UGOH/UG

221022

444

NoneNoneNone

CSH2150NBWH2200CSH2200N

NoneNoneNone

3 3 3

5-595-755-59

5-1035-103, 5-1025-103

CMBEB150BTS �

MBEB200BTSCMBEB200BTS �

—MBEB200BTF—

200200

NoneNone

OH/UGOH/UG

�44

2/4 2/4

MLOMLO

BRCH

3 3

5-725-63

5-103, 5-1025-103

MBE24L200BTSCMBE24L200BTS �

MBE24L200BTF—

Ring Style All-in-Ones (includes distribution section)100100100

NoneNoneNone

OH/UGUGOH

101010

444

12/2414/2812/24

BR2100BR2100BR2100

BRBRBR

2 4 9

5-625-665-99

5-103, 5-1025-101, 5-1005-105

MBE1224B100BTSMBE1428B100BSMBE1224B100TS

MBE1224B100BTFMBE1428B100BF—

125125125

NoneNoneNone

OH/UGOHUG

101010

444

12/2412/2418/36

BR2125BR2125BR2125

BRBRBR

2 9 5

5-625-995-65

5-103, 5-1025-1055-100

MBE1224B125BTSMBE1224B125TS—

MBE1224B125BTF—MBE1836B125BF

150150

NoneNone

OH/UGOH/UG

1022

44

4/88/8

BWH2150CSH2150N

BRCH

1919

——

——

MBER48B150BTS ��

CMBER88B150BTS ���——

150150150

NoneNoneNone

OH/UGUGUG

222210

444

832/4220/40

CSH2150NCSH2150NBWH2150

CHCHBR

3 7 6

5-605-565-64

5-103, 5-1025-1015-100

CMBE88B150BTS ��

CMBE3242B150BS �

CMBE88B150BTF ��

—MBE2040B150BF �

150150

NoneNone

OH/UGOH/UG

2210

44

20/40 4/8

BWH2150BWH2150

BRBR

— 3

5-685-73

—5-103

MBE2040B150BTS �

MBE48B150BTS— —

200200200

NoneNoneNone

OH/UGOH/UGOH/UG

102210

444

4/8 8 8

BWH2200CSH2200NBWH2200

BRCHBR

3 3 3

5-735-605-74

5-103, 5-1025-103, 5-1025-103

MBE48B200BTS �

CMBE88B200BTS ��

MBE88B200BTS

MBE48B200BTF �

CMBE88B200BTF ��

200200

NoneNone

OH/UGOH/UG

1022

44

4/8 8/8

BWH2200CSH2200N

BRCH

1919

5-885-87

5-1075-107

MBER48B200BTS ��

CMBER88B200BTS ���——

200200200

NoneNoneNone

OH/UGOHUG

444

8/16 8/166 – 2 Pole

ProvisionProvisionMain Lug

BRBRCH

1010 5

5-765-765-58

5-1055-1055-101, 5-100

MBE816P200TSCU ��

MBE816P200TS ��

CMBE1212L200BS �

——MBE1212L200BTF

200200200

NoneNoneNone

OH/UGOHUG

1010

444

6 – 2 Pole20/4020/40

Main LugBWH2200BWH2200

BRBRBR

910 6

5-785-775-64

5-100, 5-1015-105, 5-1045-101, 5-100

MBE1212L200BTSMBE2040B200TS �

MBE2040B200BS �

—MBE2040B200TF �

MBE2040B200BF �

200200200

NoneNoneNone

OH/UGOH/UGUG

222222

444

20/4020/4030/42

BWH2200BWH2200BWH2200

BRBRBR

—— 7

5-685-685-69

———

MBE2040BH200BTS �

MBE2040BH200BTF �

——MBE3042B200BF

200200200

NoneNoneNone

UGUGOH/UG

222222

444

32/424040

CSH2200NBWH2200BWH2200

CHBRBR

71212

5-565-865-86

5-101, 5-1005-1065-106

CMBE3242B200BS �

MBE4040B200BSH

MBE4040B200BTS

CMBE3242B200BF �

—MBE4040B200BTF

200200225

NoneNoneNone

OH/UGOH/UGOH/UG

221010

444

4220/4020/40

CSH2200NBWH2200BWH2225

CHBRBR

121818

5-855-685-94

5-1065-109, 5-1105-109

CMBE4242B200BTS �

MBE2040B200BTS �

MBE2040B225BTS �

—MBE2040B200BTF �

MBE2040B225BTF �

225225

NoneNone

UGUG

2222

44

30/4232/42

BWH2225CSH2225N

BRCH

7 7

5-705-56

—5-101, 5-100

—CMBE3242B225BS �

MBE3042B225BFCMBE3242B225BF �

MaximumAmpereRating

2-Pole Breaker Catalog Numbers

10 kAIC PriceU.S. $

22 kAIC PriceU.S. $

22 kAIC PriceU.S. $

100125150200

BW2100BW2125BW2150BW2200

BWH2100BWH2125BWH2150BWH2200

CSR2100NCSR2125NCSR2150NCSR2200N

Load Side Lug Kit for BW and CSR Breakers � MCBK225

Discount Symbol. . . . . . . . . . . . . . . . . . . . . . . . . 22CD

Page 5: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

5-64

For more information visit: www.eaton.com CA08101001E

Group Metering & Meter Breakers

5

Meter BreakersResidential

Mechanical Interlock Covers

Meter Breaker with Interlock Cover

Covers mechanically interlock two breakers. Covers interlock main breaker with 2-pole breaker mounted in the distribution section of the meter breakers.

Product SelectionTable 5-56. Mechanical Interlock CoverMechanical Interlock Deadfront

Meter Breaker Catalog Number

MBDF1M CMB1212B200BTS, CMB1212B200BTSD, CMB1212P200BTS, CMB1212P200BTSD

MBDF1AM CMB2424B200BTS

MBDF2M MB816B200BTS, MB816B200BTSCU, MB816P200BTS, MB816P200BTSCU, MB816P200STD

MBDF3M MB2040B200BTS, MB2040P200BTS, MB2040P200SD

MBDF4M MBE816P200TS, MBE816P200TSCU

MBDF5M MBE2040B150BF, MBE2040B150BS, MBE2040B200BF, MBE2040B200BS

MBDF6M MBE2040B200TF, MBE2040B200TS, MBE2040T200TF, MBE2040P200TS

MBDF7M CMBE324B150BF, CMBE3242B150BS, CMBE3242B200BF, CMBE3242B200BS, CMB3242B150BS, CMB3242B200BS

MBDF8M CMBE4242B200BSH, CMBE4242B200BTF, CMBE4242B200BTS

MBDF9M MBE4040B200BSH, MBE4040B200BSHH, MBE4040B200BTF, MBE4040B200BTS

Page 6: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

CA08101001E For more information visit: www.eaton.com

5-65Group Metering & Meter Breakers

5

Meter BreakersResidential

Box Styles

Figure 5-55. Five Different Styles (Shapes) of Product

Table 5-57. Box Dimensions

Table 5-58. Meter Breaker Parts

Table 5-59. Wire Size Chart

Table 5-60. Wire Size is Determined by the Circuit Breaker Installed in the Enclosure

Table 5-61. Hub Selection Chart

A B C D E F

BoxNumber

Dimensions in Inches (mm) BoxStyleHeight Width Depth

1 2 3

12.50 (317.5)23.88 (606.4)28.38 (720.7)

14.44 (366.7)14.44 (366.7)14.44 (366.7)

4.00 (101.6)5.38 (136.5)5.38 (136.5)

AAA

4 5 6

34.13 (866.8)36.13 (917.6)43.38 (1101.7)

14.44 (366.7)14.44 (366.7)14.44 (366.7)

5.38 (136.5)5.38 (136.5)5.38 (136.5)

BBB

7 8 910

46.88 (1190.6)19.75 (501.7)25.00 (635.0)32.38 (822.3)

14.44 (366.7)7.50 (190.5)

14.44 (366.7)14.44 (366.7)

5.38 (136.5)4.00 (101.6)5.38 (136.5)5.38 (136.5)

BCCC

111213141516

36.63 (930.3)34.38 (873.1)19.75 (501.7)39.91 (1013.7)23.88 (606.6)28.38 (720.9)

14.44 (366.7)22.00 (558.8)14.44 (366.7)14.44 (366.7)13.00 (330.2)13.00 (330.2)

5.38 (136.5)5.38 (136.5)5.38 (136.5)5.38 (136.5)4.94 (125.5)4.94 (125.5)

CDECFF

1718192021

34.19 (868.4)36.06 (915.9)28.38 (720.9)32.06 (814.3)25.50 (647.7)

22.13 (562.1)16.63 (422.4)14.44 (366.8)14.44 (366.8)14.44 (366.8)

5.00 (127.0)5.50 (139.7)4.94 (125.5)4.94 (125.5)4.94 (125.5)

DAACC

Description CatalogNumber

PriceU.S. $

5th Jaw KitsCompact and Standard Styles (MB & CMB)WMB StyleEUSERC Styles

MB5JAWKITWMB5J1MM5JKOP

Manual Bypass KitsRing Style Units Only (MB) 1MMBPM200

Horn Bypass KitsRingless Style Units Only (MB & CMB)EUSERC Styles

MBHBPKIT1MMBPH

Main Wire Size Range Cu/Al 60ºC or 75ºC for Line Terminals

BR250BR260BR270

#14 – 4 kcmil #4 – 1/0 kcmil #4 – 1/0 kcmil

BR280BR290BR2100

#4 – 1/0 kcmil #4 – 1/0 kcmil #4 – 1/0 kcmil

BW2125BW2150BW2200

#2 – 300 kcmil #2 – 300 kcmil #2 – 300 kcmil

BWH2125BWH2150BWH2200

#2 – 300 kcmil #2 – 300 kcmil #2 – 300 kcmil

CSR2125NCSR2150NCSR2200N

#1/0 – 250 kcmil#1/0 – 250 kcmil#1/0 – 250 kcmil

125 Ampere Main Lugs 200 Ampere Main LugsMCBK225

—— #2 – 300 kcmil

Wire/Application Maximum

Wire Size AmpereRating

Aluminum — StandardAluminum — Service EntranceCopper — Standard and Service Entrance

250 kcmil250 kcmil250 kcmil

200225225

Hub SizeDimensions in Inches (mm)

Catalog Number

PriceU.S. $

1.00 (25.4)1.25 (31.8)1.50 (38.1)

DS100H2DS125H2DS150H2

2.00 (50.8)2.50 (63.5)3.00 (76.2)

DS200H2DS250H2DS300H2

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD

Page 7: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

5-66

For more information visit: www.eaton.com CA08101001E

Group Metering & Meter Breakers

5

Meter BreakersResidential

Typical Wiring Diagrams (Residential Meter Breakers)

Figure 5-56. Catalog Numbers — CMB3242B200BS, CMBE3242B150BS, CMBE3242B200BS, CMBE3242B200BF, CMBE3242B225BS and CMBE3242B225BF

#14-2 AWG#14-4 AWG#6-2/0 AWG#6-250 AWG

Wiring Diagram Key

Service DisconnectType CSR

N

BondedNeutral

BondedNeutral

123456789

10111213

14

15

16

17

18

19

20

21

22

23242526272829303132

33

34

35

36

37

38

39

40

41

42

Line

A B

Figure 5-57. Catalog Numbers —

Figure 5-58. Catalog Number — CMBE1212L200BS

1416

22

9111315

10

468

1357

2

1820

1719

NA B

Line

#14-4 AWG#6-2/0 AWG

#6-250 AWG

Wiring Diagram Key

4

8

12

13

7

11

2

A B

NLine

Bo

nd

ed N

eutr

al

Bo

nd

ed N

eutral

#14-4 AWG#6-1/0 AWG#6-250 AWG

Wiring Diagram Key

Page 8: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

CA08101001E For more information visit: www.eaton.com

5-67Group Metering & Meter Breakers

5

Meter BreakersResidential

Typical Wiring Diagrams (Residential Meter Breakers)

Figure 5-59. Catalog Numbers — CMBP200BTS, CMBB150BTS, CMBB200BTS, CMBEB150BTS and CMBEB200BTS� Factory installed MCBK225 Kit for C/B load lugs.

Figure 5-60. Catalog Numbers — CMBE88B200BTS, CMBE88B200BTF, CMB88B200BTS, CMB88B150BTS, CMBE88B150BTS and CMBE88B150BTF

Figure 5-61. Catalog Numbers — CMBE24L125BTS and CMB24L125BTS

Figure 5-62. Catalog Numbers — MBE1224B100BTS, MBE1224B100BTF, MBE1224B125BTS and MBE1224B125BTF

Figure 5-63. Catalog Number — CMBE24L200BTS

Figure 5-64. Catalog Numbers — MBE2040B150BF, MBE2040B200BS and MBE2040B200BF

A B

BondedNeutral

LineN

A B

Install 200 Ampere MaximumService Disconnect Type CSR ➀

Wiring Diagram Key

#14-2/0 AWG#14-2 AWG#6-250 AWG

A B

1234

A B

5678

Wiring Diagram Key

#14-1/0 AWG#14-6 AWG#6-2/0 AWG#6-250 AWG#4-300 AWG

Service DisconnectType CSR 200 Ampere Maximum

Bo

nd

ed N

eutr

al

LineN

A B

BondedNeutral

LineN

A B

#14-1/0 AWG#14-6 AWG#14-1/0 AWG#6-250 AWG

1 3 4

Wiring Diagram Key

1234

#14-6 AWG#14-1/0 AWG#14-2/0 AWG#6-250 AWG

WiringDiagram Key

A

BondedNeutral

B

Main56789

101112131415161718192021222324

A B

BondedNeutralLine

N

A B

#14-6 AWG#14-1/0 AWG#6-250 AWG

1 3 4

Wiring Diagram Key

N

A B

142

35 6

91113151719

323133 34

374038

39

DisconnectType BW,BWH or CSR

Line

#14-4 AWG#6-2/0 AWG#6-250 AWG

Wiring Diagram Key

Page 9: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

5-68

For more information visit: www.eaton.com CA08101001E

Group Metering & Meter Breakers

5

Meter BreakersResidential

Typical Wiring Diagrams (Residential Meter Breakers)

Figure 5-65. Catalog Number — MBE1836B125BF

Figure 5-66. Catalog Numbers — MBE1428B100BS and MBE1428B100BF

Figure 5-67. Catalog Numbers —

Figure 5-68. Catalog Numbers — MBE2040B200BTS, MBE2040B150BTS, MBE2040BH200BTS and MBE2040BH200BTF

Figure 5-69. Catalog Number — MBE3042B200BF

Figure 5-70. Catalog Number — MBE3042B225BF

135

91113151719

23

3635

25272931

N Line

A B

Service Disconnect

Wiring Diagram Key

#14-4 AWG#6-2/0 AWG

#6-250 AWG

135

911131517192123

NLine

A B

Bo

nd

ed N

eutr

al

Bo

nd

ed N

eutral

Wiring Diagram Key

#14-4 AWG#6-2/0 AWG

#6-250 AWG

68

1012

13579

11

2

Line

A B

N

Bo

nd

ed N

eutr

al

#14-6 AWG#6-1/0 AWG#6-250 AWG

Bo

nd

ed N

eutral

Wiring Diagram Key

BondedNeutral

1516171819202122

1314

2324

1112

910

34

12

78

56

N

2728293031323334

2526

353637383940

A B

A B200 A Max.ServiceDisconnect

Wiring Diagram Key

#14-6 AWG#14-1/0 AWG#6-250 AWG

Bo

nd

ed N

eutral

LINEN A B

414042

3937

3638

3533

3234

3129

2830

2725

2426

23

181715

1416

13

111012

9

7

6

8

53

2

4

1

Service DisconnectType BW, BWH or CSR

Bo

nd

ed N

eutr

al

212022

19

Wiring Diagram Key

#14-4 AWG#6-2/0 AWG#6-250 AWG

Bo

nd

ed N

eutral

Service DisconnectType BW, BWH or CSR

Bo

nd

ed N

eutr

al

LINEN A B

414042

3937

3638

3533

3234

3129

2830

2725

2426

23

181715

1416

1311

1012

9

7

6

8

53

2

4

1

212022

19

Wiring Diagram Key

#14-4 AWG#6-2/0 AWG#6-250 AWG

Page 10: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

CA08101001E For more information visit: www.eaton.com

5-69Group Metering & Meter Breakers

5

Meter BreakersResidential

Typical Wiring Diagrams (Residential Meter Breakers)

Figure 5-71. Catalog Numbers — MBE24L125BTS and MBE24L125BTF

Figure 5-72. Catalog Numbers — MBE24L200BTS and MBE24L200BTF

Figure 5-73. Catalog Numbers — MBE48B150BTS, MBE48B200BTS, MBE48B200BTF and MB48B200BTS

Figure 5-74. Catalog Number — MBE88B200BTS

Figure 5-75. Catalog Numbers — MBEB200BTS and MBEB200BTF

Figure 5-76. Catalog Numbers — MBE816P200TS and MBE816P200TSCU

A B

1

NeutralLineN

A B

2 34 56

#14-1/0 AWG#14-6 AWG#14-2/0 AWG#6-250 AWG

Wiring Diagram Key

A B

1

NeutralLine

NA B

2 34 56

#14-1/0 AWG#14-6 AWG#14-2/0 AWG#6-250 AWG

Wiring Diagram Key

A B

200 Ampere MaximumService DisconnectType BW, BWH or CSR

A B L2L1 BondedNeutral

LineN

#14-1/0 AWG#14-6 AWG#6-2/0 AWG#6-250 AWG

Wiring Diagram Key

678

A B

200 Ampere MaximumService DisconnectType BW, BWH or CSR

A BLineN

Wiring Diagram Key

#14-1/0 AWG#14-6 AWG#6-2/0 AWG#6-250 AWG

A B

A B

MCBK225 Kit forC/B Load Lugs

Wiring Diagram Key

#14-2/0 AWG#6-2/0 AWG#6-250 AWG

200 Ampere MaximumService DisconnectType BW, BWH or CSR

BondedNeutral

LineN

A B

#14-4 AWG#6-350 kcmil#6-2/0 AWG#6-300 kcmil#6-300 kcmil

LineN

BondedNeutral

200 AmpereMaximumServiceDisconnectType BW,

Wiring Diagram Key

Page 11: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

5-70

For more information visit: www.eaton.com CA08101001E

Group Metering & Meter Breakers

5

Meter BreakersResidential

Typical Wiring Diagrams (Residential Meter Breakers)

Figure 5-77. Catalog Numbers — MBE2040B200TS and MBE2040B200TF

Figure 5-78. Catalog Number —MBE1212L200BTS

Figure 5-79. Catalog Number — MBE1212L200BTS

Figure 5-80. Catalog Number — CMBE1212L200TS

Figure 5-81. Catalog Numbers — CMB1212P200BTSD, CMB1212P200BTS and CMB1212B200BTS

Figure 5-82. Catalog Number — MB1212L200BTS

A B

Line N

BondedNeutral

200 Ampere MaximumService DisconnectType BW,

13

24

8

#14-4 AWG#6-350 kcmil#6-2/0 AWG

1

3

5

7

9

11

BondedNeutral

N

A B

#14-4 AWG#6-350 kcmil#6-2/0 AWG#6-300 kcmil

2

4

6

8

10

12

Wiring Diagram Key

A B

1

2

LINEN

A B 4

5

BondedNeutral

#14-4 AWG#6-350 kcmil#6-2/0 AWG

Wiring Diagram Key

1

3

5

7

9

11

#14-4 AWG#6-350 kcmil#6-2/0 AWG#6-300 kcmil

BondedNeutral

A BN

2

4

6

8

10

12

Wiring Diagram Key

5TH Jaw Factory Installedon CMB1212B200BTSD andCMB1212P200BTSD Only

1

3

5

7

9

11

200 AmpereMaximumService DisconnectType CSR or CSH

BondedNeutral

LineN

A B

2

4

6

8

10

12

#14-4 AWG#6-350 kcmil#6-2/0 AWG#4-300 kcmil#6-300 kcmil

WiringDiagram Key

1

3

5

7

9

11

BondedNeutral N

A B

Ground Bar

#14-2/0 AWG#6-350 kcmil#6-300 kcmil

2

4

6

8

10

12

WiringDiagram Key

Page 12: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

CA08101001E For more information visit: www.eaton.com

5-71Group Metering & Meter Breakers

5

Meter BreakersResidential

Typical Wiring Diagrams (Residential Meter Breakers)

Figure 5-83. Catalog Number — CMB2424B200BTS

Figure 5-84. Catalog Number — CMB1212L200BTS

Figure 5-85. Catalog Number — CMBE4242B200BTS

Figure 5-86. Catalog Numbers — MBE4040B200BTS and MBE4040B200BSH

Figure 5-87. Typical Wiring Diagram for CMBER88B200BTS and CMBER88B200BTF

Figure 5-88. Typical Wiring Diagram for MBER48B200BTS and MBER48B200BTF

1

3

5

7

9

11

13

15

17

19

21

23

#14-4 AWG#6-350 kcmil#6-2/0 AWG#4-300 kcmil

200 AmpereMaximumService DisconnectType CSR

BondedNeutral

LineN

A B

2

4

6

8

10

12

14

16

18

20

22

24

WiringDiagram Key

1

3

5

7

9

11

N

BondedNeutral

A B

#14-4 AWG#6-350 kcmil#6-2/0 AWG#6-300 kcmil

5th Jaw Factory Installedon CMB1212L200BTSD Only

2

4

6

8

10

12WiringDiagram Key

13579

11131517192123252729313335373941

A B

A B

BondedNeutral

2468

1012141618202224262830323436384042

#14-6 AWG

WiringDiagram Key

Factory InstalledService DisconnectType CSR

#14-1/0 AWG#6 AWG-250 kcmil

N

13579

111315171921232527293133353739

N

A B

A B

BondedNeutral

2468

10121416182022242628303234363840#14-6 AWG

WiringDiagram Key

#14-1/0 AWG#6 AWG-250 kcmil

Factory InstalledService DisconnectType BW

LineN

BA

B

ServiceDisconnect Type CSR orCSH Max 200A

12345678

SecondaryService

Disconnect70A Max

BondedNeutral

Wire Range

#14-1/0

#14-6 AWG

#5-2/0 AWG

#5-250 AWG

#4-300 AWG

A

LineN

BA

B

200A Max ServiceDisconnectType BW, BWH or CSR

SecondaryService

Disconnect70A Max

BondedNeutral

Wire Range

#14-1/0#14-6 AWG

#5-2/0 AWG#5-250 AWG

A

1357

2468

Page 13: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

5-72

For more information visit: www.eaton.com CA08101001E

Group Metering & Meter Breakers

5

Meter BreakersResidential

Typical Wiring Diagrams (Residential Meter Breakers)

Figure 5-89. Typical Wiring Diagram for Catalog Number CMB2436B200BTS

Figure 5-90. Typical Wiring Diagram for Catalog Numbers MBT48B200BTS, MBT48P200BTS, MBT48B150BTS, MBT48P150BTS

Figure 5-91. Typical Wiring Diagram for Catalog Numbers MBP200SD, CMBXB200BTS, CMBXP200BTS

Figure 5-92. Typical Wiring Diagram for Catalog Numbers CMBX3242P200BTS, CMBX3242B200BTS

Figure 5-93. Typical Wiring Diagram for Catalog Numbers CMB1212B150BTS, CMBX1212B200BTS, CMB1212B200BTS, CMB1212P200BTS, CMB1212B200BTSD, CMB1212P200BTSD, CMBX1212P200BTS

Figure 5-94. Typical Wiring Diagram for Catalog Numbers MBE2040B225BTS, MBE2040B225BTF

200A Max.Service DisconnectType CSR or CSH

BondedNeutral

A B LineN

2019

212223

1234

65

24252726

2928

3130

3332

353436

79 8

1110

1312

1514

171618

Maximum of 12 twinBreakers as Shown

#14-4 AWG#6-350 kcmil#6-2/0 AWG#4-300 kcmil

WiringDiagram Key

12 34 56 78 #6-2/0 AWG #6-350 kcmil#1-300 kcmil#6-300 kcmil

Wiring

Factory or Fieldinstalled. 150 A or200 A Max. ServiceDisconnect

Line N

A B

Diagram Key

#6-2/0 AWG #6-350 kcmil#1-300 kcmil#6-300 kcmil

Wiring

CMBXB200BTSfactory installed 200 A Max ServiceDisconnect type CSR

MBP200SDinstall 200 A Max Service Disconnect type BW, BWH or CSR

CMBXB200BTS &CMBXP200BTSincluded lever bypass meter socket

Line N

A B

Diagram Key

1

3

5

7

9

1113

1517

19

2123252729313335

3937

2

4

6

8

10

1214

161820

2428

22

32

26

3638

34

30

40

4241

#14-4 AWG #6-350 kcmil#6-2/0 AWG#6-300 kcmil

Wiring

Line N

Bonded/Neutral

CMBX3242P200BTS200 A Max.Service DisconnectType CSR or CSH(not included)

CMBX3242B200BTS200 A Max.Service DisconnectFactory InstalledType CSR or CSH

Maximum of10 Twin Breakers as shown

A B

Diagram Key

Includes LeverBypass MeterSocket

5TH Ja

CMBX1212B200BTS &CMBX1212P200BTS include lever bypass meter socket

w Factory Installedon CMB1212B200BTSD andCMB1212P200BTSD Only

1

3

5

7

9

11

200 AmpereMaximumService DisconnectType CSR or CSH

BondedNeutral

LineN

A B

2

4

6

8

10

12

#14-4 AWG#6-350 kcmil#6-2/0 AWG#4-300 kcmil#6-300 kcmil

WiringDiagram Key

#14-6 AWG #14-1/0 AWG#6-250 AWG

WiringDiagram Key

225 A Max.ServiceDisconnect

A B

A

N

BondedNeutral

B

Page 14: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

CA08101001E For more information visit: www.eaton.com

5-73Group Metering & Meter Breakers

5

Meter BreakersResidential

Typical Wiring Diagrams (Non-EUSERC Meter Breaker Design)

Figure 5-95. Catalog Numbers — MBB150BTSC, MBB150BTSCR, MBB200BTSCR and MBB200BTSC

Figure 5-96. Catalog Numbers — MBB150BTS, MBP200SD, MBB200BTS, MBP200BTS, MBP200BTSD, CMBXB200BTS and CMBXP200BTS� Use MCBK225 for C/B Load Lugs.

Figure 5-97. Catalog Numbers — MB816P200STD, MB816B200BTS, MB816B200BTSCU, MB816P200BTS, MB816P200BTSCU and MB816P200BTSD

Figure 5-98. Catalog Numbers — MB2040P200SD, MB2040B200BTS, MB2040P200BTS, MB2040B150SD and MB2040B200SD

Figure 5-99. Catalog Numbers — MBE1224B125TS and MBE1224B100TS

A B

200 Ampere MaximumService DisconnectType CSR

BondedNeutral

Line N

#6-2/0 AWG#6-350 kcmil#6-250 kcmil#1-300 kcmil

Included inMBB150BTSCR

Wiring Diagram Key

A B

#6-2/0 AWG#6-350 kcmil#1-300 kcmil#6-300 kcmil

LineN

BondedNeutral

200 Ampere MaximumService DisconnectType BW, BWH or CSR ➀

Wiring Diagram Key

A B

13

24

15 16

#14-4 AWG#6-350 kcmil#6-2/0 AWG#6-300 kcmil#6-300 kcmil

LineN

BondedNeutral

200 Ampere Maximum

Disconnect

Wiring Diagram Key

A B

13

24

810121416182022

262830

34363840

32

LineN

BondedNeutral

200 Ampere MaximumService DisconnectType BW, BWH or CSR

#14-4 AWG#6-350 kcmil#6-2/0 AWG

Wiring

#14-4 AWG#14-1/0 AWG#6-350 kcmil

WiringDiagram Key

13579

11131517192123

125 AmpereMaximumService DisconnectType BR, or BRH

BondedNeutral

LineN

A B

EquipmentGround

2468

1012141618202224

Page 15: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

5-74

For more information visit: www.eaton.com CA08101001E

Group Metering & Meter Breakers

5

Meter BreakersResidential

Dimensions and Knockouts (Residential Meter Breakers) — Dimensions in Inches (mm)

Figure 5-100. Knockouts for Stucco and Surface Units Catalog Numbers — CMBE3242B200BF, CMBE3242B225BF, MBE2040B200BF, MBE2040B150BF, MBE1428B100BF, MBE1212L200BTF, MBE1836B125BF and MBE1212L200BTS

Table 5-62. Top Endwall (Surface)

� Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed.

Table 5-63. Top Endwall (Stucco)

Figure 5-101. Knockouts for Stucco and Surface Units Catalog Numbers — CMBE3242B150BS, CMBE3242B200BS, CMBE3242B225BS, CMBE1212L200BS, MBE2040B200BS, MBE1428B100BS, MBE1212L200BTS, CMB3242B150BS and CMB3242B200BS

Table 5-64. Bottom EndwallHub ProvisionCatalog Number

PriceU.S. $

DS100H2DS125H2DS150H2

DS200H2DS250H2DS300H2DS900AP (Adapter Plate if using DS___H1 hubs only) �

Knockout Size Dimensions in Inches (mm)

Quantity

1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5)1.00, 1.25, 1.50 (25.4, 31.8, 38.1).50, .75, 1.00 (12.7, 19.1, 25.4)

111

.50, .75 (12.7, 19.1)

.50 (12.7)57

3.50(88.9)

Keyhole Knockouts on Sides for Stucco Units Only.

Top Stucco

4.94(125.4)

Bottom

Knockout Size Dimensions in Inches (mm)

Quantity

.50 (12.7)

.50, .75 (12.7, 19.1)

.50, .75, 1.00 (12.7, 19.1, 25.4)

741

1.00, 1.25, 1.50, 2.00 (25.4, 31.8, 38.1, 50.8)1.25, 1.50, 2.00, 2.50, 3.00 (31.8, 38.1, 50.8, 63.5, 76.2)

11

Discount Symbol. . . . . . . . . . . . . . . . . . . . . . . . . 22CD

5.31(134.9)

Top Surface

Bottom

4.94(125.4)

Page 16: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

CA08101001E For more information visit: www.eaton.com

5-75Group Metering & Meter Breakers

5

Meter BreakersResidential

Dimensions and Knockouts (Residential Meter Breakers) — Dimensions in Inches (mm)

Figure 5-102. Knockouts for Stucco and Surface Units Catalog Numbers — CMBE88B150BTF, CMBE88B200BTF, MBE24L125BTF, MBE24L200BTF, MBE48B200BTF, MBEB200BTF, MBE1224B100BTF and MBE1224B125BTF

Table 5-65. Top Endwall (Surface)

� Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed.

Table 5-66. Top Endwall (Stucco)

Figure 5-103. Knockouts for Stucco and Surface Units Catalog Numbers — CMBB150BTS, CMBB200BTS, CMBP200BTS, CMBE24L125BTS, CMB24L125BTS, CMBE24L200BTS, CMBEB200BTS, CMBEB150BTS, CMBE88B150BTS, CMBP200BTS, CMBE88B200BTS, MBE24L125BTS, MBE24L200BTS, MBE48B150BTS, MBE48B200BTS, MBE88B200BTS, MBEB200BTS, MBE1224B100BTS, MBE1224B125BTS, CMB88B150BTS, CMB88B200BTS and MB48B200BTS

Table 5-67. Bottom Endwall

Hub ProvisionCatalog Number

PriceU.S. $

DS100H2DS125H2DS150H2

DS200H2DS250H2DS300H2DS900AP (Adapter Plate) �

Knockout Size Dimensions in Inches (mm)

Quantity

1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5)1.00, 1.25, 1.50 (25.4, 31.8, 38.1).50, .75, 1.00 (12.7, 19.1, 25.4)

111

.50, .75 (12.7, 19.1)

.50 (12.7)33

Keyhole Knockouts on Sides for Stucco Units Only.

Top Stucco

Bottom

3.50(88.9)

4.94(125.4)

Knockout Size Dimensions in Inches (mm)

Quantity

.50 (12.7)

.50, .75 (12.7, 19.1)

.50, .75, 1.00 (12.7, 19.1, 25.4)

741

1.00, 1.25, 1.50, 2.00 (25.4, 31.8, 38.1, 50.8)1.25, 1.50, 2.00, 2.50, 3.00 (31.8, 38.1, 50.8, 63.5, 76.2)

11

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 22CD

Top Surface

Bottom

5.31(134.9)

4.94(125.4)

Page 17: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

5-76

For more information visit: www.eaton.com CA08101001E

Group Metering & Meter Breakers

5

Meter BreakersResidential

Dimensions and Knockouts (Residential Meter Breakers) — Dimensions in Inches (mm)

Figure 5-104. Knockouts for Stucco and Surface Units Catalog Number — MMBE2040B200TF

Table 5-68. Top Endwall (Surface)

� Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed.

Table 5-69. Top Endwall (Stucco)

Figure 5-105. Knockouts for Stucco and Surface Units Catalog Numbers — MBE1224B100TS, MBE1224B125TS, MBE816P200TS, MBE816P200TSCU, MBE2040B200TS, CMB1212P200BTS, CMB1212P200BTSD, CMB1212B200BTS, MB1212L200BTS and CMB1212L200BTS

Table 5-70. Bottom EndwallHub ProvisionCatalog Number

PriceU.S. $

DS100H2DS125H2DS150H2

DS200H2DS250H2DS300H2DS900AP (Adapter Plate) �

Knockout Size Dimensions in Inches (mm)

Quantity

1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5)1.00, 1.25, 1.50 (25.4, 31.8, 38.1).50, .75, 1.00 (12.7, 19.1, 25.4)

111

.50, .75 (12.7, 19.1)

.50 (12.7)33

Keyhole Knockouts on Sides for Stucco Units Only.

Top Stucco

Bottom

3.50(88.9)

4.94(125.4)

Knockout Size Dimensions in Inches (mm)

Quantity

.50 (12.7)

.50, .75 (12.7, 19.1)

.50, .75, 1.00 (12.7, 19.1, 25.4)

741

1.00, 1.25, 1.50, 2.00 (25.4, 31.8, 38.1, 50.8)1.25, 1.50, 2.00, 2.50, 3.00 (31.8, 38.1, 50.8, 63.5, 76.2)

11

Discount Symbol. . . . . . . . . . . . . . . . . . . . . . . . . 22CD

Top Surface

Bottom

5.31(134.9)

4.94(125.4)

Page 18: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

CA08101001E For more information visit: www.eaton.com

5-77Group Metering & Meter Breakers

5

Meter BreakersResidential

Dimensions and Knockouts (Residential Meter Breakers) — Dimensions in Inches (mm)

Figure 5-106. Knockouts for Stucco and Surface Units

Table 5-71. Top Endwall (Surface)

� Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed.

Table 5-72. Top Endwall (Stucco)

Table 5-73. Bottom Endwall

3.44(87.3)

Top Surface

Top Flush

MBE4040B200BTF

Top Surface

Bottom Bottom

2-1/2-inch Hub

CMBE4242B200BTSMBE4040B200BTS

MBE4040B200BSH

5.31(134.9)

4.94(125.4)

5.31(134.9)

4.94(125.4)

Hub ProvisionCatalog Number

PriceU.S. $

DS100H2DS125H2DS150H2

DS200H2DS250H2DS300H2DS900AP (Adapter Plate) �

Knockout Size Dimensions in Inches (mm)

Quantity

1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5).50, .75 (12.7, 19.1)

23

Knockout Size Dimensions in Inches (mm)

Quantity

.50, .75 (12.7, 19.1)

.50, .75, 1, 1.25 (12.7, 19.1, 25.4, 31.8)1.00, 1.25, 1.50, 2.00, 2.50 (25.4, 31.8, 38.1, 50.8, 63.5)1.00, 1.25, 1.50, 2.00, 2.50, 3.00 (25.4, 31.8, 38.1, 50.8, 63.5, 76.2)

6211

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 22CD

Page 19: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

5-78

For more information visit: www.eaton.com CA08101001E

Group Metering & Meter Breakers

5

Meter BreakersResidential

Figure 5-107. Knockout Configurations and Dimensions for Catalog Numbers MBER48B200BTS and CMBER88B200BTS

Figure 5-108. Knockout Configurations and Dimensions for Catalog Numbers CMBXP200BTS, CMBXB200BTS, CMBX1212P200BTS and CMBX3242P200BTS, CMBX3242B200BTS, CMBX1212B200BTS

Figure 5-109. Surface Unit Knockout Configurations and Dimensions for MBE2040B200BTS, MBE2040B225BTS, MBE2040B200BTF and MBE2040B225BTF

Figure 5-110. Semi-Flush Stucco Unit Knockout Configurations and Dimensions for MBE2040B200BTS, MBE2040B225BTS, MBE2040B200BTF and MBE2040B225BTF

Figure 5-111. Knockout Configurations and Dimensions for Catalog Numbers MBT48B125BTS, MBT48B150BTS, MBT48B200BTS and MBT48P200BTS

4-15/16"

Top Surface

Bottom End

Mounting Surface

5-5/16"

Bottom

Top Surface

4-15/16"

5-5/16"

Page 20: Meets EUSERC Requirements Product Description Features ... · For more information visit: CA08101001E Group Metering & Meter Breakers 5 Meter Breakers Residential Table 5-50. Combination

August 2007

CA08101001E For more information visit: www.eaton.com

5-79Group Metering & Meter Breakers

5

Meter BreakersResidential

Dimensions and Knockouts (Non-EUSERC Meter Breaker Design) — Dimensions in Inches (mm)

Figure 5-112. Knockouts for Non-EUSERC Units Catalog Numbers — MBB150BTS, MBB200BTS, MBP200BTS, MB816P200BTS, MB816P200BTSCU, MB816P200BTSD, MB816B200BTS, MB816B200BTSCU, MB2040P200BTS, MB2040B200BTS, MBP200BTSD, MBP200SD, MB816P200STD, MB2040B150SD, MB2040B200SD and MB2040P200SD

Table 5-74. Top Endwall (Surface)

� Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed.

Figure 5-113. Knockouts for Non-EUSERC Units Catalog Numbers — CMB2424B200BTS, MBB150BTSCR, MBB200BTSCR, MBB150BTSC, MBB200BTSC and CMB2436B200BTS

Table 5-75. Bottom Endwall

Figure 5-114. Knockouts for Non-EUSERC Units Catalog Number — CHMMB100BTS

Table 5-76. Bottom Endwall

Figure 5-115. Knockouts for Non-EUSERC Units Catalog Numbers — CHMMB150BTS and CHMMB200BTS

Table 5-77. Bottom Endwall

Hub ProvisionCatalog Number

PriceU.S. $

DS100H2DS125H2DS150H2

DS200H2DS250H2DS300H2DS900AP (Adapter Plate) �

5.31(134.9)

Top Surface

Bottom

4.94(125.4)

Knockout Size Dimensions in Inches (mm)

Quantity

.31 (7.9)

.50 (12.7)

.50, .75 (12.7, 19.1)

.75, 1.00 (12.7, 25.4)1.25, 1.50, 2.00, 2.50 (19.1, 38.1, 50.8, 63.5)1.50, 2.00, 2.50, 3.00 (38.1, 50.8, 63.5, 76.2)

332121

Bottom

4.94(125.4)

5.31(134.9)

Top Surface (Catalog Numbers with SC and SCR Suffix Only)

Knockout Size Dimensions in Inches (mm)

Quantity

.31 (7.9)

.50 (12.7)

.50, .75, 1.00, 1.25, 1.50, 2.00, 2.50 (12.7, 19.1, 25.4, 31.8, 38.1, 50.8, 63.5)1,00, 1.25, 1.50, 2.00, 2.50 (25.4, 31.8, 38.1, 50.8, 63.5)

112

1

Bottom

4.94(125.4)

Knockout Size Dimensions in Inches (mm)

Quantity

.31 (7.9)

.50 (12.7)

.50, .75, 1.00, 1.25, 1.50, 2.00, 2.50 (12.7, 19.1, 25.4, 31.8, 38.1, 50.8, 63.5)1.00, 1.25, 1.50, 2.00, 2.50, 3.00 (25.4, 31.8, 38.1, 50.8, 63.5, 76.2)

112

1

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 22CD

Bottom

4.94(125.4)