mechanical legend and abbreviations
TRANSCRIPT
ABBREVIATIONS - MECHANICALABV ABOVE
AC AIR CONDITIONING UNIT
ACC AIR COOLED CONDENSER
ACD AUTOMATIC CONTROL DAMPER
AD ACCESS DOOR
AHU AIR HANDLING UNIT
AL ACOUSTICAL LINING
ARCH ARCHITECTURAL
ATC AUTOMATIC TEMPERATURE CONTROL
B BOILER
BD BALANCING DAMPER
BDD BACK DRAFT DAMPER
BMS BUILDING MANAGEMENT SYSTEM
BO BLANK OFF
BHP BRAKE HORSE POWER
BTU BRITISH THERMAL UNIT
CC COOLING COIL
CD CEILING DIFFUSER
CFF CAP FOR FUTURE
CFM CUBIC FEET PER MINUTE
CG CEILING GRILLE
CH CHILLER
CO CLEAN OUT
COMP COMPRESSOR
CONV CONVECTOR
CR CEILING REGISTER
CT COOLING TOWER
CU CONDENSING UNIT
CW CONDENSER WATER
DB DRY BULB
DIA DIAMETER
DN DOWN
DX DIRECT EXPANSION
(E) EXISTING TO REMAIN
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
ECH ELECTRIC CABINET HEATER
EDB ENTERING DRY BULB
EF EXHAUST FAN
EFF EFFICIENCY
ELEV ELEVATOR
EHC ELECTRIC HEATING COIL
EUH ELECTRIC UNIT HEATER
EWB ENTERING WET BULB
EWT ENTERING WATER TEMPERATURE
°F DEGREES FAHRENHEIT
F FILTER
FBO FURNISHED BY OTHERS
FC FLEXIBLE CONNECTION (DUCT OR PIPE)
FCC FIRE CONTROL CENTER
FCU FAN COIL UNIT
FD FUSIBLE LINK FIRE DAMPER W/ DUCT ACCESS DOOR
FLR FLOOR
FLA FULL LOAD AMPS
FPB FAN POWERED BOX
FPI FINS PER INCH
FRE FIRE RATED ENCLOSURE
FSD COMBINATION FIRE AND SMOKE DAMPER
FT FEET
FTR FIN TUBE RADIATOR
GLY GLYCOL
GPM GALLONS PER MINUTE
GX GENERAL EXHAUST
HC HEATING COIL
HTP HEAT PUMP
HP HORSE POWER
HR HOUR
HRU HEAT RECOVERY UNIT
HTW HEATWHEEL
HV HEATING AND VENTILATING UNIT
HW HOT WATER
HX HEAT EXCHANGER
ID INSIDE DIMENSION
KW KILOWATT
KWH KILOWATT HOURS
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LD LINEAR DIFFUSER (CEILING, WALL, SILL OR FLOOR)
LRA LOCK ROTOR AMPS
LWS LOUVER WITH WIRE SCREEN
LWT LEAVING WATER TEMPERATURE
MAT MIXED AIR TEMPERATURE
MAX MAXIMUM
MBH THOUSAND BTU PER HOUR
MCC MOTOR CONTROL CENTER
MFG MANUFACTURER
ABBREVIATIONS - MECHANICALMFS MAXIMUM FUSE SIZE
MIN MINIMUM
MUA MAKE UP AIR UNIT
MOCP MAXIMUM OVERCURRENT PROTECTION
(N) NEW
NC NORMALLY CLOSED
NFA NET FREE AREA
NIC NOT IN THIS CONTRACT
NK NECK
NO NORMALLY OPEN
NTS NOT TO SCALE
OAI OUTSIDE AIR INTAKE
OBD OPPOSED BLADE DAMPER
OD OUTSIDE DIMENSION
P PUMP
PD PRESSURE DROP
PHC PRE-HEAT COIL
PHX PLATE HEAT EXCHANGER
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH (GAUGE)
PSIA POUNDS PER SQUARE INCH ABSOLUTE
(R) EXISTING TO BE RELOCATED
RA RETURN AIR
RF RETURN FAN
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RPM REVOLUTIONS PER MINUTE
SA SUPPLY AIR
SAD SEE ARCHITECTURAL DRAWINGS
SD SMOKE DAMPER
SF SUPPLY FAN
SED SEE ELECTRICAL DRAWINGS
SENS SENSIBLE
SM SHEET METAL
SP STATIC PRESSURE
STP STAIR PRESSURIZATION
SQFT SQUARE FEET
ST SOUND TRAP
SX SMOKE EXHAUST
TF TRANSFER FAN
TRD TRANSFER DUCT
TRG TRANSFER GRILLE
TX TOILET EXHAUST
TYP TYPICAL
UH UNIT HEATER
UON UNLESS OTHERWISE NOTED
VAR VARIABLE
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
VFD VARIABLE FREQUENCY DRIVE
W/ WITH
WB WET BULB
WG WATER GAUGE
WMS WIRE MESH SCREEN
WO-SIZE WALL OPENING - [SIZE]
(X) EXISTING TO BE DEMOLISHED
(300) CUBIC FEET OR AIR PER MINUTE OR GALLONS PER MINUTE
CEILING DIFFUSER
1-WAY BLOW 3-WAY BLOW
4-WAY BLOW2-WAY BLOW
A
MECHANICAL LEGEND AND ABBREVIATIONS
HOT WATER SUPPLYHWSHWS
HOT WATER RETURNHWRHWR
CONDENSER WATER SUPPLYCWSCWS
CONDENSER WATER RETURNCWRCWR
CHILLED WATER SUPPLYCHWSCHWS
CHILLED WATER RETURNCHWRCHWR
EXPANSION LOOP (SIZE AxB)
(3'-0"x6'-0")
(3'-0"x6'-0")
PIPING LEGEND
CONCENTRIC REDUCER (INCREASER)
ECCENTRIC REDUCER (INCREASER)
BASKET TYPE STRAINER
ELBOW TURNED UP
ELBOW TURNED DOWN
TOP PIPE CONNECTION
LUBRICATED PLUG VALVE
LOCKSHIELD GLOBE VALVE
SOLENOID VALVE
BUTTERFLY VALVE (MANUAL)
BUTTERFLY VALVE (MOTORIZED)
R
D
18x12
18x12
DUCTWORK LEGEND
U
MISCELLANEOUSA
B
18
18
EXPANSION COMPENSATOR
FLEXIBLE BALL JOINT EXPANSION COMPENSATOR
DIRT POCKET
UNION
SIGHT GLASSVALVE IN VERTICAL
MANUAL AIR VENT
AUTOMATIC AIR VENT
THERMOMETER
PIPE SENSOR WELL (THERMOMETER)
PRESSURE GAUGE AND COCK
REFRIGERANT EXPANSION VALVE
PIPE GUIDE
CENTER LINE
HEAT TRACED PIPING
PIPE SLEEVE
C
REFRIGERANT LIQUID PIPING RL RL
REFRIGERANT SUCTION PIPING RS RS
REFRIGERANT-SAFETY VALVE RELIEF LINE R-SV R-SV
HOT GAS PIPING HG HG
DOMESTIC COLD WATER MAKE-UP DCW DCW
ARROW INDICATES DIRECTION OF FLOW
PITCH PIPE DOWN IN DIRECTION OF ARROW
DRAIN LINEDD
SLOPED CHANGE IN PIPE ELEVATION
FLEXIBLE CONNECTION
SHUT-OFF VALVE
GLOBE VALVE
CHECK VALVE
AUTOMATIC THREE-WAY CONTROL VALVE
AUTOMATIC TWO-WAY CONTROL VALVE
RELIEF VALVE S
S
ANGLE RELIEF VALVE S S
PRESSURE REDUCING VALVE (PRV)
BOTTOM PIPE CONNECTION
DUPLEX STRAINER
BALL VALVE
"Y" TYPE STRAINER WITH HOSE ENDBLOWOFF VALVE
CAPPED PIPE WITH SHUT-OFF VALVE
LD-A,48x1,8(300) (300)
LD-A,48x1,8
#P
2M3.1
CT1-1
SR-A,12x8
1M2.1
WO-SIZE
(200)
SR-A,12x8(200)
(200)ER-C,12x8
(200)ER-C,12x8
T #
H #
S
CD-1,12x12(550)
CD-1,12x12(550)
CM #
B
DUCTWORK LEGEND (CONTINUED) CONTROLS LEGEND
AUTOMATIC FLOW CONTROL VALVE
PUMP
CALIBRATED BALANCE VALVE
TH #
18
18
RETURN/EXHAUST REGISTER OR GRILLE WITHFLEXIBLE DUCT CONNECTION
CEILING DIFFUSER WITH FLEXIBLE DUCTCONNECTION
RETURN/EXHAUST REGISTER OR GRILLE
ROUND CEILING DIFFUSER WITH FLEXIBLEDUCT CONNECTION
FLOOR SWIRL DIFFUSER
UNDERCUT DOOR
FIRE RATED ENCASED DUCT
TRANSFER GRILLES ON BOTH SIDES OFPARTITION OR WALL (SIZE)
WALL OPENING ABOVE HUNG CEILING (SIZE)
SUPPLY REGISTER WITH AIR OUTLET DEVICEDESIGNATION
RETURN OR EXHAUST REGISTER OR GRILLE WITH AIR INLET DEVICE DESIGNATION
TERMINAL UNIT WITH/WITHOUT HEATING COIL
FAN POWERED TERMINAL UNITWITH/WITHOUTHEATING COIL
LINEAR DIFFUSER WITH PLENUM
LINEAR DIFFUSER
BACK DRAFT DAMPER WITH DUCT ACCESSDOOR
COMBINATION FIRE AND SMOKE DAMPERWITH DUCT ACCESS DOOR
SMOKE DAMPER WITH DUCT ACCESS DOOR
FUSIBLE LINK FIRE DAMPER WITH DUCTACCESS DOOR
AUTOMATIC CONTROL DAMPER
VOLUME DAMPER IN DUCT
DUCT SPLIT WITH SPLIT SIZE
RADIUS ELBOW
RECTANGULAR SUPPLY DUCT UP
RECTANGULAR SUPPLY DUCT DOWN
RECTANGULAR RETURN OR EXHAUSTDUCTUP
RECTANGULAR RETURN OR EXHAUSTDUCTDOWN
ROUND DUCT, UP
ROUND DUCT, DOWN
BEAMPENETRATION
SLOPING RISE IN DUCTWORK
SLOPING DROP IN DUCTWORK
DUCT SIZE (CLEAR INSIDE DIMENSION)FIRST FIGURE INDICATES PLAN SIZE
ROUND DUCT DIAMETER SIZE (CLEARINSIDEDIMENSION)
OVAL DUCT SIZE
ACOUSTIC LINING IN DUCT (DUCT SIZENOTEDINDICATES INSIDE DIMENSIONS)
FLEXIBLE CONNECTION
FLEXIBLE DUCT
DUCT COIL WITH ACCESS DOOR
TOTALIZING BTU METER
EMERGENCY BREAK GLASS SWITCH FOR EQUIPMENTSHUT-DOWN
TEMPERATURE-PRESSURE TEST FITTING
FLOW MEASURING STATION
FLOW SWITCH
CARBON MONOXIDE SENSOR WITH ZONE DESIGNATION
CARBON DIOXIDE SENSOR WITH ZONE DESIGNATION
TEMPERATURE SENSOR/THERMOSTAT WITH ZONEOR EQUIPMENT DESIGNATION
HUMIDISTAT/HUMIDITY SENSOR WITHHUMIDIFIER DESIGNATION
COMBINATION TEMPERATURE/HUMIDITY SENSOR
DUCT SMOKE DETECTOR SUPPLIED BY ELECTRICALTRADE, INSTALLED BY MECHANICAL TRADE
STATIC PRESSURE SENSOR WITH DESIGNATION
NEW WORK
EXISTING WORK
EXISTING WORK TO BE REMOVED
POINT OF NEW CONNECTION TO EXISTING WORK
OVAL
DIAMETER
RISER DESIGNATION
SECTION DESIGNATION
DETAIL DESIGNATION
EQUIPMENT DESIGNATION
TERMINALDESIGNATION
AIR OUTLET/INLETDEVICEDESIGNATION
LINEAR DIFFUSERDEVICE DESIGNATION
RISER SERVICE
RISER NUMBER
SECTION NUMBERDRAWING NUMBER
DETAIL NUMBERDRAWING NUMBER
EQUIPMENT TYPEEQUIPMENT FLOORAND NUMBER
3-24THE NUMBER ON THE FLOOR
FLOOR OR LEVEL
TYPENECK ORFACE SIZECFM
TYPELENGTH & SLOTSIZEPLENUMINLET SIZECFM
SIDE, TOP OR BOTTOM DUCT ACCESS DOOR
ELBOW WITH TURNING VANES
CD
ACCESSAREA
ACCESSAREA
#R REFRIGERANT SENSOR WITH DESIGNATION
RECTANGULAR OR SQUARE TO ROUND OROVAL TRANSITION
PIPE ANCHOR
PIPE GUIDE
ROUND CEILING DIFFUSER
F
F
DIFFERENTIAL PRESSURE SWITCHDP
B
RECTANGULAR BRANCH TAKEOFFWITHBALANCING DAMPER
DIFFERENTIAL PRESSURE SENSORDP
3-24
HW1
PIPE BLIND FLANGE
PIPE CAP
DUCT END/CAP
8x6
8x616x6
16x6
"Y" TYPE STRAINER
PRESSURE GAUGE WITH LOOP
BEAM PENETRATION
PIPING LEGEND (CONTINUED)PIPING LEGEND (CONTINUED)
E
#
KEYNOTE
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
18:5
5 P
M
05.22.2015
1309100
M-000
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALLEGEND &ABBREVIATIONS
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
MECHANICAL DRAWING LISTSHEET NUMBER SHEET NAME
M-000 MECHANICAL LEGEND & ABBREVIATIONSMH100A MECHANICAL FLOOR PLAN - BASEMENT LEVELMH100B MECHANICAL FLOOR PLAN - BASEMENT LEVEL SERVICE YARDMH101A MECHANICAL FLOOR PLAN - LEVEL 1MH101B MECHANICAL FLOOR PLAN - LEVEL 1 PARKINGMH102 MECHANICAL FLOOR PLAN - LEVEL 2MH103 MECHANICAL FLOOR PLAN - LEVEL 3MH104 MECHANICAL FLOOR PLAN - LEVEL 4MH105 MECHANICAL FLOOR PLAN - LEVEL 5MH106 MECHANICAL FLOOR PLAN - LEVEL 6MH107 MECHANICAL FLOOR PLAN - LEVEL 7MH108 MECHANICAL FLOOR PLAN - LEVEL 8MH109 MECHANICAL ROOF LEVELMP100A MECHANICAL PIPING FLOOR PLAN - BASEMENT LEVELMP100B MECHANICAL PIPING FLOOR PLAN - BASEMENT LEVEL SERVICE YARDMP101A MECHANICAL PIPING FLOOR PLAN - LEVEL 1MP101B MECHANICAL PIPING FLOOR PLAN - LEVEL 1 PARKINGMP102 MECHANICAL PIPING FLOOR PLAN - LEVEL 2MP103 MECHANICAL PIPING FLOOR PLAN - LEVEL 3MP104 MECHANICAL PIPING FLOOR PLAN - LEVEL 4MP105 MECHANICAL PIPING FLOOR PLAN - LEVEL 5MP106 MECHANICAL PIPING FLOOR PLAN - LEVEL 6MP107 MECHANICAL PIPING FLOOR PLAN - LEVEL 7MP108 MECHANICAL PIPING FLOOR PLAN - LEVEL 8MP109 MECHANICAL PIPING ROOF PLANM-301 MECHANICAL SECTIONSM-401 MECHANICAL ENLARGED PLANSM-501 MECHANICAL DETAILSM-502 MECHANICAL DETAILSM-503 MECHANICAL DETAILSM-601 MECHANICAL SCHEDULESM-602 MECHANICAL SCHEDULESM-603 MECHANICAL SCHEDULESM-701 MECHANICAL CONTROL DIAGRAMSM-702 MECHANICAL CONTROL DIAGRAMSM-703 MECHANICAL CONTROL DIAGRAMSM-801 MECHANICAL AIR RISER DIAGRAMM-802 MECHANICAL HYDRONIC RISER DIAGRAMM-803 CHILLER & BOILER HYDRONIC PIPING DIAGRAM
UP
DN
VEHICLE SPB-231
INMATEELEV.
E5
STAIRST4-B
INMATEELEV.
E8
STAIRST5-B
ELEV.E6
CORR.B-100Z
EVID. STOR.B-130
EM. POWERB-105
FM OFFICEB-160
DEPUTYSTATIONB-200B
NORMALPOWERB-110
PED ADULTS.P.
B-212
OFF.STATION
B-211
JCB-213
J.C.B-101
CORRB-110Z
MUSTER/MTGB-209A
M CELLB-222
M CELLB-223
M CELLB-221
M CELLB-220
SEC. VEST.B-209 TOILET/
SHOWERB-209B
F GROUPCELLB-206
F CELLB-207
F CELLB-208
F CELLB-210
F JUV. CELLB-205
M CELLB-202
M CELLB-203
M GROUPCELLB-204
SEC VESTB-214
SEC VESTB-219
M GROUPHOLDING
B-218
M GROUPCELLB-217
M GROUPCELLB-216
M CELLB-215
SEC VESTB-230
GUNLOCKERS
B-200
CORR.B-205Z
SERV./PRIVATE
ELEV.LOBBYB-100
LOADINGDOCK/RECEIVING/
PACKAGESCREEN
B-165
M JUV. CELLB-201
MAIL DIST.B-115
ELEV.E1
ELEV.E7
ELEV.LOBBYB-002
EQUIP ROOMB-138B
TOILETB-138A
CENTRALCONTROL
B-138
S.P.B-137
FIRECOMMAND
B-140
DOMESTICWATERENTRYROOMB-163
RECYCLINGCLOSET
B-161
MDFB-135
FIRE PUMPROOMB-139
FMB-162
OLYMPICSEC
B-120
FURN STOR.B-125B
JANITORSTOR.B-125C FIRE TANK
ROOMB-139A
MEDICALEQUIP STOR
B-001
SHOPSB-125A
STAFF TOIL.B-136
CORRB-161Z
CORRB-200Z
CORRB-137Z
N-C INT.B-220
N-C INT.B-219
STAIRB-305
VEST /LOBBYB-200A
CORR.B-215Z
VEST /LOBBYB-240
CORR.B-211Z
CORR.B-201Z
CORRB-161ZCORRB-161Z
1 1.1 2 3 4 5 6 6.9 7 8
A
B
C
D
E
F
F.5
6.15.25.14.24.13.23.12.22.11.61.4
VAV0-2
VAV0-4
VAV0-10
VAV0-11
VAV0-3
VAV0-6
VAV0-8
VAV0-5
VAV0-9
VAV0-7
26x18
6ø
6ø12x6
16x14
8x8 14x8
8x612x6
12x8
EFB-3
EFB-4
CM
CM
VAV0-1
20x14
FCUB-1
FCUB-3
8ø
CD-A,
(110)
RG-A,(110)
RG-A,
(100)
CD-A,(100)
CD-A,(100)
RG-A
(230)
CD-B, 8x8
(80), TYP-2
EG-B, 8x8
(170), TYP-2
CD-A,(80)
RG-A,(80)
6ø
6ø
EG-B, 6x6(70), TYP-2
CD-B, 6x6
(40), TYP-3
EG-B, 6x6(80)
EG-B, 6X6
(70), TYP-4
EG-B, 8x8(100), TYP-4
EG-B, 12x12(300)
EG-B, 12x12(250)
CD-A,
(40), TYP-3
CD-A,(175), TYP-4
CD-A,(150), TYP-2
RG-A,(120), TYP-3
RG-A,(60)
CD-A,(60)
CD-A,(135), TYP-3
RG-A,
(460)
CD-A, 8x8(160)
EG-B, 12x12(250)
EG-B, 12x12(130)
CD-B, 6x6(60)
CD-B, 6x6(120), TYP-2
10x10
8ø8ø
12x10 8ø
6ø
6ø
6ø
12x10
6ø6ø
6ø
6ø
8ø
6ø6ø
8ø
8ø
6ø
6ø
8ø
6ø
6ø
6ø
6ø6ø
14ø
8ø6ø
8ø
10x10
12x10
8ø
RG-A, 8X8(120), TYP-2
8ø
10ø
18x14
6ø
RG-A(200)
HPB-2
FSD-B-1
SP1
SP3
6ø
EFB-5
EG-A, 8X8
(100)
CD-B, 6x6(40), TYP-4
CD-B, 6x7
(100)
UHB-1
UHB-2
UHB-3
CD-A
(60)
ER-A, 24X24
(375), TYP-2
ER-A, 24X24
(100)
6ø
10ø
CD-A(150)
VAV0-13
VAV0-12
CD-A(50), TYP-2
EG-A, 24X24
(200)
EFB-5
28x1820x16
20x1412x8
12x8
14x10
20x16
EG-A, 24X24(350)
FSD-B-2
TX1
SG-A, 36X28(2700)
SG-A, 36X30(2700)
RFM2-1
RFM2-1
18x12
18x12
RG-A(1500), TYP-2
CD-A(750), TYP-2
CD-A(100), TYP-2
6ø
8ø
FPBB-1
6ø
FCUB-4
18x12
18x12
FCUB-2
CD-B, 8X8(60), TYP-4
CD-A
(300)
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
B
A
Key Plan
5/21
/201
5 6:
19:3
3 P
M
05.22.2015
1309100
MH100A
NEW SNOHOMISHCOUNTYCOURTHOUSE
CSG
ZMS
MECHANICALFLOOR PLAN -BASEMENT LEVEL
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
NUMBERED NOTESPROVIDE OUTSIDE AIR LOUVER WITH 2.4 SF OF NFA.
BACK-UP FCU SERVING THE CONTROL CENTER CONNECTEDTO A MINI-SPLIT SYSTEM IN THE SERVICE YARD
1
2
MH100B
MH100A
MH100B
MH100A
2
1
SHEET NOTES1. THRMOSTAT LOCATION TO BE COORDINATED W/ ARCH. ONE THERMOSTAT PER BOX.2. CARBON DIOXIDE CONTROL VENTALATION IN ALL COURTROOMS & MEETING ROOMS.3. PROVIDE FLEX DUCT CONNECTIONS TO ALL DIFFUSERS AT A MAXIMUM LENGTH OF 5FT.
DNUP
MUSTER/MTGB-209A
SEC. VEST.B-209 TOILET/
SHOWERB-209B
F GROUPCELLB-206
M GROUPCELLB-204
LOADINGDOCK/RECEIVING/
PACKAGESCREEN
B-165
TRANSFORMERVAULTB-302
TRANSFORMERVAULTB-301
DOMESTICWATERENTRYROOMB-163
SERVICEYARDB-310
STAIRST6-B
STAIRB-305
SERVICEYARDB-310
SERVICEYARDB-310
SERVICEYARDB-310
SERVICEYARDB-310
2.4 NFA 1.2 NFA
B1
B2
CHWP3
CHWP2
CHWP1
CWP1
CWP2
CWP3
HWP1
HWP2
HWP3
CH2
CH1
VFD's M-4011
CT1
1 1.1 2 3 4 5 6 6.9 7 8
P-B
A
EFB-1
50x24
50x24
56x26
EFB-2
20x14 20x14 50x24
20x20
20x20
SFB-1
SFB-2
P-A
1
CM
HPB-2
20x20
20x20
4
28x1820x16
8ø8ø
CMCM
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
B
A
Key Plan
5/21
/201
5 6:
19:3
8 P
M
05.22.2015
1309100
MH100B
NEW SNOHOMISHCOUNTYCOURTHOUSE
CSG
ZMS
MECHANICALFLOOR PLAN -BASEMENT LEVELSERVICE YARD
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
NUMBERED NOTESTRANSFORMER EXHAUST CONCRETE DUCT.PROVIDE WITH 3 HR FIRE RATING.
1
MH100B
MH100A
MH100B
MH100A
PROVIDE EXHAUST LOUVER WITH 8.0 SF OF NFA.2
2
PROVIDE EXHAUST LOUVER WITH 0.85 SF OF NFA.3
3
TO COORDINATE MECH ROOM FOR FLOOD PROTECTION4
COMBUSTION AIR AND EXHAUST FLUE RISER LOCATINO TO BE COORDINATED.5
5
SHEET NOTES1. THERMOSTAT LOCATION TO BE COORDINATED W/ ARCH. ONE THERMOSTAT PER TERMINAL UNIT.2. CARBON DIOXIDE DEMAND CONTROL VENTILATION IN ALL COURTROOMS & MEETING ROOMS.3. PROVIDE FLEX DUCT CONNECTIONS TO ALL DIFFUSERS AT A MAXIMUM LENGTH OF 5FT.
LOADING DOCK EXHAUST DUCTWORK TO RUN TIGHT TO EXTERIOR WALL.6
6
UP
DN
FPB1-4
FPB1-27
FPB1-7
FPB1-8
FPB1-28
FPB1-29
FPB1-14
FPB1-5
FPB1-15
FPB1-11
FPB1-33
FPB1-31
FPB1-12
FPB1-13
FPB1-32
FPB1-17
FPB1-19
FPB1-20
FPB1-21
FPB1-2
FPB1-1
FPB1-25
FPB1-24
FPB1-23
FPB1-22
FPB1-9
FPB1-34
FPB1-10
VAV1-2
VAV1-5
VAV1-1
VAV1-3
VAV1-4
VAV1-18
VAV1-17
VAV1-12
VAV1-15
VAV1-13
VAV1-14
VAV1-11
VAV1-9
VAV1-7
VAV1-10
VAV1-8
VAV1-6
VAV1-16
FPB1-18
COMMISSIONERCOURTROOM
1-A00
ELEV.E8
ELEV.E5
STAIRST4-1
ELEV.E6
ELEV.E1
STAIRST5-1
CELL1-A14
OFF. STAT.1-A13
SOUNDLOCK1-B05
SOUNDLOCK1-A05
ATTY. INT.1-B01
W. TOILET1-010
M. TOILET1-012
SEC. VEST.1-A10
N-C INT.1-A11
STAIRST3-1
COMMISSIONERCOURTROOM
1-B00
COMMISSIONERCOURTROOM
1-C00
ATTY. INT.1-A01
ATTY. INT.1-D01
COMMISSIONERCOURTROOM
1-D00
TECH EQUIP1-442
ELEC.1-441
PUBLICELEV.
LOBBY1-002
STAIRST2-1
SEC. VEST.1-B10
SEC. ELEV.ALCOVE
1-A17
EQUIP.STOR.1-445
A/V ROOM1-444
SHAFTS2
SHAFTS1
PUBLICLOBBY1-004
CELL1-B14
DISTRICTHEARING
ROOM1-E00
STOR.1-011
TECH EQUIP1-401
ATTY. INT.1-C01SOUND
LOCK1-C05
SOUNDLOCK1-D05
STAFFTOILET1-430
N-C INT.1-B12
SOUNDLOCK1-E05
IDF1-425
STAFFTOILET1-403
SERV./PRIVATE
ELEV.LOBBY1-440
VEST.1-441Z
CORR.1-420Z
IDF1-203
ELEC1-021
TSER1-020
ELEC.1-402
MEDIAROOM1-E01
WRKALCOVE
1-C02EQUIP.STOR.1-121
SOUNDLOCK1-443Z
A/V ROOM1-429
TECH EQUIP1-426
WAITING1-015
N-C INT.1-A12
N-C INT.1-B11
STAIR # 1ST1-1
VEST.1-008
CEREMONIALCOURTROOM/
JURYASSEMBLY
1-215
SECUREJUROR
WAITING1-223
CORR.1-202Z
CART/PODIUM
STORAGE1-201
M. TOILET1-212
JURYCHECK-IN/QUEUING
1-200
COURTADMINSTAFF1-220
W. TOILET1-210
A/V1-202
SUP. CLERK1-221
JURYLOUNGE
1-204
CORR.1-221Z
TECHNOLOGYBAR
1-210Z
WORK/FILES/
STORAGE1-222
WAITING1-005
WAITING1-006
LAWLIBRARY/STOR
1-125
WAITING1-001
WAITING1-003
PUBLICVENDING
1-001A
OFFICE1-126
ATTY ADMIN1-306
WAITING1-300
OPERATIONSMGR1-305
COPY/STOR/DENNYYOUTH1-302
OPENOFFICE1-301
CORR.1-100Z
M LOCKER /SHOWERS
1-102A
M. TOILETS1-102
F. TOILETS1-104
JC1-105
F LOCKER /SHOWERS
1-104A
INJ. ROOM1-101
LACT. ROOM1-103
STAFFBREAKRM
1-106
ELEC.1-404
SHOW/CAUSECONF ROOM
1-116
OPENOFFICE
WORK AREA1-118
STOR/WORKRM
1-117
ATTY. BARASSN.1-120
OPENOFFICE1-115
COMMOFFICE1-451
COMMOFFICE1-450
CORR.1-450Z
WRK/ FILES/STOR1-437 COMM
OFFICE1-436
COMMOFFICE1-427
COMMOFFICE1-421
DRUGCOURTCOORD.
1-515
DRUGCOURTCOORD.
1-514
DRUGCOURTCOORD.
1-513
DRUGCOURTSPVR.1-512
SPCLTYCOURT MGR
1-511
CORR.1-510ZCLOS.
1-516TOILET1-502
WAITINGROOM1-500
VEST.1-600Z
CORR.1-301Z
OPENOFFICE1-600
CORR.1-004Z
CONF/DINING1-420
CORR.1-C00Z
PUBLICCOUNTER
1-123
ELEV.E7
ELEV.E2
ELEV.E3
COMM.TOILET1-435
COMM.TOILET1-428
CORR.1-435Z
VEST1-436Z
CORR.1-404Z
TBD1-110
CORR.1-020Z
CORR.1-021Z
ATTY HOTEL1-132
CORR.1-325Z
CORR.1-501Z
VEST1-003Z
VEST1-005Z
CORR.1-002Z
SHAFTS3
TBD1-122
OBSERVATION1-502
CORR.1-325ZCORR.1-325Z
TX1
16x14
VAV1-19
36x48 36x48
48x18
16x14
20x16
45x18
12x10
14x10
34x20
34x20
22x26
20x26
30x16
30x16
12x10
20x1816x12
12x12
20x2622x26
22x26
12x12
16x1414x10
18x12
32x18
30x12
24x12
24x12 20x20
30x10 26x10 20x10 10ø
1 1.1 2 3 4 5 6 6.9 7 8
A
B
C
D
E
F
F.5
6.15.25.14.24.13.23.12.22.11.61.4
18x14
40x22
24x16
FPB1-3
LD-A, 2'(200), TYP-4
LD-B, 4'(400), TYP-2
LD-A, 3'(250)
RG-B, 4'(450), TYP-4
FPB1-26
LD-B(300), TYP-2
LD-A, 2'(100)
RG-B, 4'
(550), TYP-2
18x1220x14
LD-B, 2'(110), TYP-4
LD-B, 2'
(110), TYP-4
CD-A(200)
FPB1-6
CD-A
(150)CD-A
(190), TYP-3CD-A(100)
CD-A
(150)
CD-A(140), TYP-5
CD-A(100), TYP-2
10x8
CD-A(360)
12x10
8ø
CD-A(200)
CD-A(120)
8ø
CD-A(175), TYP-2
LD-B, 4'(300), TYP-2
LD-A, 2'(100)
LD-A, 2'(110), TYP-4
LD-B, 4'(300), TYP-2
RG-B, 2'(550), TYP-2
RG-B, 4'(350), TYP-2
CD-A
(250), TYP-2
8ø
8ø
CD-A
(200), TYP-2
12x10
CD-A(625), TYP-2
18x16
16x12
12ø
12ø
12ø
CD-A
(575), TYP-212ø
CD-A(140)
CD-A
(60)
CD-A(540), TYP-4
CD-A(125), TYP-2
CD-A
(100)
12ø 10ø
CD-A
(225), TYP-2
CD-A
(120)
CD-A(100)
CD-A
(150)
CD-A
(150)
CD-A(400
CD-A(170)
CD-A
(200)CD-A(150)
CD-A(50)
CD-A(100)
8ø
CD-A(140), TYP-2
CD-A(170), TYP-3
CD-A(250)
CD-A(30), TYP-2
CD-A
(50)CD-A(250)
CD-A(150)
CD-A(190)
RG-A(200)
RG-A(110)
RG-A
(120)
RG-A
(250)
RG-A(150)
RG-A(140), TYP-5
RG-A(300)
RG-A(360)
RG-A(850)
RG-A(120)
RG-A(200)
RG-A
(600) RG-A(150)
RG-A
(100)
RG-A(1150), TYP-4
RG-A
(60)
RG-A
(1400
RG-A
(250)
RG-A
(100)
RG-A(365), TYP-2
RG-A(40)
RG-8, 4'(460), TYP-3
LD-8, 3'(235), TYP-6
CD-A(40)
LD-8, 2'(200), TYP-4
RG-A(300)
RG-A(400)
RG-A(450)
CD-A(450)
RD-8, 4'
(475), TYP-2
RG-A(170)
8ø 10ø 12x1010x10
10ø
10ø8ø
8ø10ø
12x10
RG-A(500)
CD-A(110), TYP-2
RG-A(150)
RG-A(50)
RG-A(100)
CD-A(70)
RG-A(70)
FCU1-1
FCU1-2
FCU1-3
10ø
8ø
8ø
6ø
8x8 10x8
10ø
12x12
12x10
8ø 8x8
8ø
10ø
8ø
12x60
8x8
8ø
10ø
10ø
8ø
8ø
8ø8ø
10ø
8ø
6ø 8ø
12x12 10ø 8ø
10ø10x8
8ø8ø
12x10
12x12
10ø
RG-A
(200)
12x12
8ø
8ø 10ø
10x8
10ø
12x12
10x8
6ø
6ø6ø12x8
10ø
10ø10ø 8ø
8x8
10x8
12x10
10ø
10ø 6ø8ø
12x12
8ø
12x12
12x10
8ø
8ø 8ø
8ø
8ø8ø
12x1012x10
8ø 6ø
12x10
8ø
12x1014x10
14x10
8ø 10ø
10ø
10ø 10ø
12x12
8ø
6ø
12x12
8ø
10x10
10x10
12ø
12x8
10ø
10x108ø
12x10
8ø
10x8
16x12
10x1012x108ø
12x10
12x1012x10
12x108ø8ø12x1012x10
16x12
10x10
12x12
10ø
10ø10ø
10ø12x12
12x12 12x12
12x12
12x12
8ø8ø
10ø
8ø
10ø
12x10
10ø10ø
10ø
8ø 12ø
10ø
10ø
10ø
8ø
10ø
10ø
10ø
12x12
10ø
12x12
10ø10ø
10ø
10ø10ø
10ø
8ø10ø
12ø 10ø12ø 12ø
10ø
12ø 12ø 12x12
12x10
12x12
8ø 10ø10ø
8ø
6ø
12x12
12x10
16x1214x10
10ø
12ø
10ø
10ø
10ø10ø
10ø
12x1212x12
16x12
8ø16x12
16x12
8ø 10ø
CD-B, 8x8(70), TYP-2
8ø
CD-B, 8x8
(50), TYP-3
CD-A
(110)
RG-A(260)
12x8
EG-A, 16x16
(500), TYP-2
CD-A(200)
EG-A, 12x12
(375), TYP-4
EG-A, 8x8(120)
10ø
12ø10ø
10ø
12ø
10ø16x14
16x1
4
16x14
16x1
4
16x14
EG-A, 8x8(70), TYP-2
8ø
8ø
8ø10ø 12x8
10ø
EG-A, 8x8
(120), TYP-2
14x10
10ø 6ø
8ø
EG-A, 8x8(130)
EG-A, 8x8
(80)
CD-A
(100) CD-A(50), TYP-5
RG-A
(100)
RG-A
(50), TYP-5
CD-A
(100)
CD-A(75), TYP-2
RG-A
(75), TYP-2
RG-A
(100)
6ø
8ø 10ø
8ø
26x18
26x1
6
20x14
20x14
8ø
12x1218x12
LD-A, 2'(100)
12ø
12ø
EG-A, 12x12(350), TYP-2
10ø
12ø
10ø
12ø
16x14
18x16
FSD-1-1
FSD-1-2
FSD-1-3
FSD-1-4
FSD-1-6
FSD-1-5
26x16
10ø
EF1-2
EF1-1
CD-A(80)SP
1
SA2
SA4
SP2
SA3
SA1
SP3EF
1-2
CD-A(50)
RG-A(700)
CD-A
(250), TYP-3
16x16
8ø
CD-A(200)
UHB-3
FSD-1-7 40x22
FSD-1-8
16x12
18x18
18x18
12x10
12x10
EF1-3
CD-A
(50), TYP-2
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
B
A
Key Plan
5/21
/201
5 6:
19:4
7 P
M
05.22.2015
1309100
MH101A
NEW SNOHOMISHCOUNTYCOURTHOUSE
CSG
ZMS
MECHANICALFLOOR PLAN -LEVEL 1
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
NUMBERED NOTESNOT USED1
MH101B
MH101A
MH101B
MH101A
SHEET NOTES1. THERMOSTAT LOCATION TO BE COORDINATED W/ ARCH. ONE THERMOSTAT PER BOX.2. CARBON DIOXIDE CONTROL VENTILATION IN ALL COURTROOMS & MEETING ROOMS.3. PROVIDE FLEX DUCT CONNECTIONS TO ALL SUPPLY DIFFUSERS AT A MAXIMUM LENGTH OF 5FT.
DN
COMMOFFICE1-451
WRK/ FILES/STOR1-437 COMM
OFFICE1-427
COMMOFFICE1-421
DRUGCOURTCOORD.
1-515
DRUGCOURTCOORD.
1-514
DRUGCOURTCOORD.
1-513
DRUGCOURTSPVR.1-512
SPCLTYCOURT MGR
1-511
VEST1-436Z
GENERATOR1-701
COOLINGTOWER1-702
SECUREPARKING
1-700
CORR.1-501Z
GENERATOR1-701
SECUREPARKING
1-700
GENERATOR1-701
SECUREPARKING
1-700
GENERATOR1-701
GENERATOR1-701
1 1.1 2 3 4 5 6 6.9 7 8
P-B
A
P-A
20x16
20x201
CT1
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
B
A
Key Plan
5/21
/201
5 6:
19:5
6 P
M
05.22.2015
1309100
MH101B
NEW SNOHOMISHCOUNTYCOURTHOUSE
CSG
ZMS
MECHANICALFLOOR PLAN -LEVEL 1 PARKING
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
NUMBERED NOTESTRANSFORMER VAULT EXHAUST LOUVER. MIN 10 FT ABOVEGRADE. PROVIDE 8.0 SF OF NFA.
1
MH101B
MH101A
MH101B
MH101A
COMBUSTION AIR AND EXHAUST FLUE RISER FROM BOILERS INMECHANICAL BASEMENT.
2
2
SHEET NOTES1. THRMOSTAT LOCATION TO BE COORDINATED W/ ARCH. ONE THERMOSTAT PER BOX.2. CARBON DIOXIDE CONTROL VENTALATION IN ALL COURTROOMS & MEETING ROOMS.3. PROVIDE FLEX DUCT CONNECTIONS TO ALL DIFFUSERS AT A MAXIMUM LENGTH OF 5FT.
UP
DN
FPB2-15
FPB2-5
FPB2-16
FPB2-4
FPB2-17
FPB2-3
FPB2-11
FPB2-7
FPB2-6
FPB2-13
FPB2-10
FPB2-9
FPB2-14
FPB2-8
VAV2-12
VAV2-11
VAV2-13
VAV2-15
VAV2-17
VAV2-16
VAV2-18
VAV2-14
VAV2-10
VAV2-9
VAV2-8
VAV2-7
VAV2-6
VAV2-5
VAV2-3
VAV2-1
VAV2-4
VAV2-21
VAV2-20
VAV2-19
ELEV.E5
ELEV.E8
STAIRST4-2
STAIRST5-2
ELEV.E1
W. TOILET2-010
ST. TOILET2-512
M. TOILET2-012
ELEV.E3
FINANCEMGR2-281
HD STORVAULT2-287
MICROFICHESTOR.2-248
ST. TOILET2-284
TELE ROOM2-250
SECURESTOR.2-511
S.C.A. STOR.2-506
SCOC MGR2-279
OPENOFFICE2-510
MAIL/COPY/WKRM2-280A
STOR.2-276
SUPPLY/STOR.2-621
SUPPORTWORKAREA2-510A
ELEC.2-286
ELEC.2-620
FIN. FILE RM2-282
W. TOILET2-247A
HD STORVAULT2-246
FIN. STOR/STOR/VAULT2-285
OPENSHELVING
AREA -VAULT2-236
JRARECORDS
MGR2-240
STAIRST3-2
SCA MGR2-515
SERV./PRIVATE
ELEV.LOBBY2-513
ELEV.E6
SHAFTS1
SHAFTS2
PUBLICELEV.
LOBBY2-002
CUST. SERV.AREA2-270
SUP. CLERK2-260
IDF2-277
PROB OFCR2-602
PROB OFCR2-603
WORK/COPY2-610D
SUPERVISOR2-610B
RECEPTION /WAITING
2-600
PROBFILING/STOR
2-610A
STOR.2-615
FILES/ FILEROOM2-616
CORR2-601Z
CORR2-004Z
STAIRST2-2
STOR.2-011
SEALED ANDHD STORRECORDS
VAULT2-237
SECURITYSCREENING
2-105
GUNREMOVAL
1-109
RECD'SSPECIALIST
2-604
S.C.A. STOR.2-505
MARSHALSTATION
1-110
SECURITYQUEUING
2-102
STAIRST3-2STAIRST3-2
OPEN OFC2-215
ELEC2-230
SECURITYSCREENING
2-106
SECURITYSCREENING
2-107
ENTRY VEST.2-100
SERV UNIT2-283
SERVUNIT/COPY
2-227
CLRK OFCOURTS
2-228
EVIDENCESTOR2-231
CHIEFDEPUTY
CLRK2-226
JOA MGR2-222
COPY/PRINT/WORK
AREA2-206
CS MGMTJUV MGR
2-202
IDF2-201
STAFFMEETING
ROOM2-013
STAFFMEETING
ROOM2-014
STORAGEROOM2-209
FILES/STOR.2-217
ELEV.E2
ELEV.E7
OPEN OFC2-205
OPEN OFC2-200
OPEN OFC2-225
OPEN OFC2-610
DIST. CLRK.2-630
SUPR. CRT.ADMIN.2-501
SUPPLY/FILE STOR
2-221SERV UNIT/LOCKERS
2-208
CORR.2-207Z
WAITING2-006
WAITING2-005
OPEN OFC2-249
MENTALHEALTHCOORD
2-601
EXIT VEST.2-101
WAITING2-220
OPEN OFC2-235
OPEN OFC2-280
CORR2-279Z
CORR2-250Z
ST.TOILET2-216 CORR.
2-015Z
VEST.2-008
SHAFTS3
SUP. CLERK2-260
CORR2-274Z
CART STOR2-207
STAIRST1-2
LOBBY2-115
CORR2-003Z
CORR2-002Z
CORR2-001ZCORR
2-001A
CORR.2-222Z
CORR.2-205Z
CORR.2-510Z
CORR.2-617Z
36x48
36x24
36x48
UH2-1
LD-B, 6'
(1100), TYP-2
18x12
20x10 20x16
20x10
VAV2-22
10ø
10ø
10x10
24x16
12ø10x8
16x14
12ø
10x8
12ø
8x8
26x20
36x208ø
8ø
12x10
FPB2-12
16x148ø
8ø
10ø10x10
10ø
18x16
10ø6ø8ø12x10
14x10
10ø
12x10
8x8
10x8
12ø
14x10
10ø
12ø
10ø
10ø10ø
8ø
8ø
10ø
10ø
10x8
10ø
8ø
14ø
8ø
8ø
12ø
10ø
8ø
10ø
10x8
12ø
10ø
10ø 8ø10x10
14x8
10ø
10ø
10ø
8ø
10ø8ø
18x16
6ø
6ø
6ø
6ø
6ø
6ø
6ø
8ø
8ø10ø
8ø
10ø
12ø
8ø 10ø
10ø10ø
14x10
1 1.1 2 3 4 5 6 6.9 7 8
A
B
C
D
E
F
F.5
6.15.25.14.24.13.23.12.22.11.61.4
8ø
12x12
10ø
CD-A,(360), TYP-2
CD-A, 8"(100)
8ø
10øCD-A,(350), TYP-2
CD-A,(250), TYP-2 6ø 8ø
6ø
CD-A,(50), TYP-3
RG-A,
(500), TYP-2
CD-A,(175), TYP-3
10ø
CD-A,(100), TYP-2
8ø
12ø
10ø
CD-A,(210), TYP-3
RG-A,
(400), TYP-3
10ø
10ø
CD-A,(325), TYP-2
CD-A,(100)
CD-A,
(250)
RG-A,(950)
8ø
6øRG-A,(120)
CD-A,(120)
CD-A,(80)
RG-A,(80)
CD-A,
(120), TYP-2
12ø 12ø
RG-A,(230)
RG-A,(250)
CD-A,(250)
6ø
6ø
8ø 8ø
RG-A,(60)
CD-A,(60), (TYP-2)
RG-A(60)
CD-A,(60), TYP-2
RG-A(120)
CD-A,(50)
RG-A(50)
RG-A,
(110)
CD-A,(110)
RG-A,(200)
CD-A,(100)
CD-A
(100)
CD-A,
(350), TYP-2
RG-A,(650), TYP-2
CD-A,(300), TYP-2
10ø
10ø
10ø
10ø
8ø8ø8ø
LD-B, 2'(140), TYP-3
CD-A,(325), TYP-2
RG-A,(650), TYP-2
6ø
8ø
8ø
CD-A,
(75), TYP-2
10ø
CD-A,
(310), TYP-2
10ø
12ø
10ø
CD-A,(30)
RG-A,(30)
CD-A,
(70)
CD-A,
(300)
CD-A,(80)
CD-A,(350)
12ø
10ø
6ø
6ø
10ø
RG-A
(350)
CD-A(250)
RG-A(230), TYP-2
8ø
8ø
18x1
220
x16
20x1
6
20x18
20x1
8
26x18
40x20
28x2
022
x16
26x1
820
x16
CD-A,
(150)
CD-A,
(100)
RG-A,
(100)
CD-A,
(350)
CD-A,(250)
RG-A,(500)
RG-A,(250)
10ø10ø
16x12
18x1
616
x14
CD-A,
(450), TYP-2
RG-A,
(100)
RG-A,(100)
CD-A,(190), TYP-2
RG-A,
(100)
CD-A,
(50), TYP-2
RG-A,(50)
CD-A,(100) CD-A,
(100)
CD-A,
(110), TYP-2
CD-A,(100) 8ø
RG-A,
(360), TYP-2
8ø8ø
CD-A,
(150), TYP-2
RG-A,(425), TYP-2
6ø
10ø
10ø
CD-A,(300)
CD-A,(350)
RG-A,(650)
12ø
10ø 10ø 10ø
12ø14ø 10ø
CD-A,
(250), TYP-5RG-A,(250)
FPB2-1A
FCU1
FCU2-3
FCU2-2
EF2-1
EG-A, 8X8
(120)
EG-A, 8X8(120)
EG-A, 12x12(300)
20x14
20x14
EG-A, 16x16(500), TYP-2
36x2040x20
RG-B, 2'
(200), TYP-6
FSD-2-1
FSD-2-2
FSD-2-3
FSD-2-4
FSD-2-6
FSD-2-5
EG-A, 8X8(60)
SP1
SA2
SA4
SP2
SA1
SA3
SP3
TX1
16x16
CD-A(200)
8ø
8ø
RG-A
(200)
RG-A(100)
RG-A
(750)
CD-A(30)
RG-A(700)
CD-A(90)
ER-A, 8X8(100)
8ø
8ø
16x8
14ø
14x12
10ø
1
1 1
FSD-2-6
RG-A,(XX), TYP-2
RFM2-1
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
20:0
2 P
M
05.22.2015
1309100
MH102
NEW SNOHOMISHCOUNTYCOURTHOUSE
CSG
ZMS
MECHANICALFLOOR PLAN -LEVEL 2
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
NUMBERED NOTESDUCT SIZED FOR POTENTIAL CONVERSION OF HD STORAGE TO OFFICE1
SHEET NOTES1. THERMOSTAT LOCATION TO BE COORDINATED W/ ARCH. ONE THERMOSTAT PER BOX.2. CARBON DIOXIDE CONTROL VENTILATION IN ALL COURTROOMS & MEETING ROOMS.3. PROVIDE FLEX DUCT CONNECTIONS TO ALL SUPPLY DIFFUSERS AT A MAXIMUM LENGTH OF 5FT.
DN
FPB3-20
FPB3-6
FPB3-7
FPB3-24
FPB3-8
FPB3-25
FPB3-26
FPB3-27
FPB3-10
FPB3-11
FPB3-28
FPB3-13
FPB3-16
FPB3-12
FPB3-18
FPB3-31
FPB3-30
FPB3-29
FPB3-32
VAV3-6
FPB3-15
FPB3-14
VAV3-1
VAV3-10
FPB3-5
VAV3-2
VAV3-4
VAV3-5
VAV3-7
VAV3-8
VAV3-3
FPB3-17
ELEV.E3
ELEV.E1
STAIRST2-3
STOR.3-011
CORR.3-004Z
ATTY. INT.3-D02
ATTY. INT.3-D04
N-C INT.3-D11
N-C INT.3-C11
STNDDISTRICT
COURTROOM3-B00
TECH EQUIP3-411 EVID STOR
3-412
A/V ROOM3-413
STAFFTOILET3-414
ASST.DIRECTOR
3-443STORAGE
3-444
OPENOFFICE3-440
DIRECTOR3-442
IDF3-434
STOR3-433
STAFFTOILET3-404 EQUIP STOR
3-405
STOR3-408
JUDICIALOFFICE3-452
ROBINGROOM3-471
FILEPROCESS
3-470
TOILET3-471A
TOILET3-463
SOUNDLOCK3-460TOILET
3-461
ELEC.3-457
FURN. STOR.3-456
FILES3-453
OPENOFFICE3-450
WRK/ FILE/STOR/ SERV
UNIT3-451
LARGE CELL3-D14
SHAFTS2
ELEV.E8
INMATEDOCK3-D15
SEC. VEST.3-D10
N-C INT.3-D12
OFF. STAT.3-C13
N-C INT.3-C12
SEC VEST3-C10
SEC. ELEV.ALCOVE
3-C17
CRIMINALHEARING
ROOM3-D00
SEC. VEST.3-A10
N-C INT.3-A11
N-C INT.3-B11
SEC. VEST.3-B10
ELEV.E5
SINGLECELL3-A14
SINGLECELL3-B14
EVID STOR3-407
TECH EQUIP3-409
SEC. ELEV.ALCOVE
3-A17
OFF. STAT.3-A13
SHAFTS1
STAIRST4-3
SERV./PRIVATE
ELEV.LOBBY3-415
CONFERENCEROOM3-441
TOILET3-432A
JUDICIALOFFICE3-432
OPENOFFICE3-430
ELEV.E6
JUDICIALOFFICE3-431TOILET
3-431A
ELEC.3-424TOILET
3-421
SOUNDLOCK3-420
TOILET3-423
JURY DELIB.3-422
A/V ROOM3-401 EVID STOR
3-403
SOUNDLOCK3-401Z
N-C INT.3-A12
N-C INT.3-B12
M. TOILET3-012
W. TOILET3-010
STAIRST3-3
TOILET3-452A
SINGLECELL3-C14
SINGLECELL3-C15
STAIRST5-3
VEST.3-476Z
ELEC.3-454
PUBLICELEV.
LOBBY3-002
CORR.3-411Z
ATTY. INT.3-B01
VICT/ WITWAITING
3-C01
SOUNDLOCK3-B05
SOUNDLOCK3-A05
PRESIDINGJUDGE'S
COURTROOM3-C00
SOUNDLOCK3-C05
ATTY. INT.3-C02
ATTY. INT.3-A01 ATTY HOTEL
3-B02
SOUNDLOCK3-D05ATTY. INT.
3-D01
STNDDISTRICT
COURTROOM3-A00
WAITINGAREA3-004
WAITINGAREA3-003
WAITINGAREA3-001
ATTY. INT.3-D03
STAIRST3-3
MAIN FILE3-119
INTERVIEW3-102
FINGERPRINT3-101
RECEPT/WAIT3-100
EMPLOYEEBADGING
3-104
CIVIL FILE3-105
IDF3-108
CIVILSUPVSR
3-112
SUP/STOR3-111
REC SUPVSR3-115
RECORDSBULLPEN
3-114
STORAGE/SUPPLIES/LET
MAILBOXES3-120
F. MARSHALCHANGE/WEAPONLOCKER
3-124
MARSHALOFC3-123
MARSHALOFC3-122
DATA ENTRY3-117
M. MARSHALCHANGE/WEAPONLOCKER
3-121
CORR3-121Z
ELEC3-125
OPENOFFICE3-103
WAITINGAREA3-005
WAITINGAREA3-006
STAFF SRVCMANAGER
3-109
VEST.3-008
OPENOFFICE3-102A
OPENOFFICE3-107
OPENOFFICE3-113
OPENOFFICE3-116
CORR.3-108Z CORR.
3-111ZCORR.3-114Z
CORR.3-130Z
LOCKERS /SERVICE
UNIT3-118
CORR.3-D01Z
CORR.3-C00Z
VEST.3-412Z
CORR3-407Z
ELEV.E7
ELEV.E2
JURY DELIB.3-462
WRK/ FILE/STOR3-402
SOUNDLOCK3-460Z
VEST.3-475Z
EVID STOR3-455
SHAFTS3
CORR.3-402Z
16x14
LD-B, 7'(1000), TYP-3
LD-B, 7'(1000), TYP-3
FPB2-1
22x14
14x12
22x14
14x12
16x14
36x34
LD-B, 4'(450)
LD-B, 8'(1500)
RG-B, 4'(600), TYP-5
16x14
22x14 22x14
FPB2-1B
FPB2-1C
FPB3-3
FPB3-19
FPB3-4
14x1010ø
12x12
14x12
18x18
30x1820x16
30x18FPB3-21
FPB3-22
FPB3-2
10ø
30x14
18x1830x18
30x18
CD-A
(250), TYP-2
CD-A
(110), TYP-2
CD-A(175), TYP-2
CD-A(110), TYP-2
CD-A(150)
CD-A(110), TYP-2
CD-A
(175), TYP-2
CD-A(160), TYP-3
20x12
6ø
30x20
20x16
16x12
10ø
10ø10ø
10x10
10ø
12x8
10ø
CD-A
(200) CD-A(175), TYP-2
CD-A
(250), TYP-2
CD-A
(170)
CD-A
(50)
CD-A
(50)
10x10
10ø
10ø
10x10
LD-A, 3'(200)
LD-B, 5
(400), TYP-2
LD-A, 2'(200), TYP-4
LD-B, 3'(300), TYP-2
10ø
10ø
10x10
10ø
1 1.1 2 3 4 5 6 6.9 7 8
A
B
C
D
E
F
F.5
6.15.25.14.24.13.23.12.22.11.61.4
LD-A, 2'(175), TYP-4
LD-B, 4'(400), TYP-2
LD-A, 3'(300)
RG-B, 4'
(450)
10x10
10ø10ø
8x8
12x12
LD-A(175), TYP-4
LD-B, 4'(400), TYP-2
LD-A(300)
RG-B, 4'
(450)
10x10
10ø 10ø
8x8
12x12
24x32
30x40 FPB3-1
LD-B, 4'(500), TYP-2
LD-B(500)
LD-B, 4'(500) LD--B, 4'
(400), TYP-4
8ø
CD-A
(120), TYP-2
CD-A
(300)
CD-A(200)
CD-A(125), TYP-2
CD-A(100) CD-A
(150)
CD-A(360), TYP-2
CD-A(250)
CD-A(250)
CD-A(350)
12x10
14x12 10ø10ø
10ø10ø10ø
CD-A(400)
CD-A(100), TYP-5
RG-A(125), TYP-2
RG-A
(200)
RG-A(300)RG-A
(450), TYP-2
RG-A(350)
RG-A(600)
RG-A(250)
RG-A(50)
RG-A(440), TYP-2
RG-A(400)
CD-A(60)
RG-A
(250)
RG-A(60)
CD-A(40)
RG-A
(40)
10x10
10ø
10ø
LD-B, 4'(375), TYP-2
10ø
14x10
10ø
LD-A, 2'(200)
LD-A, 4'(375), TYP-4
LD-B,(200), TYP-2
RG-B, 4'(400), TYP-4
RG-A(150)
RG-A(500)
RG-A(170)
RG-A(60)
CD-A
(60)
CD-A
(120)
RG-A(120)
RG-A(220)
RG-A
(350)
10ø
10ø
8ø 6ø
12x812x8
8ø
10ø
8ø 10ø
8ø
14x10
8ø
8ø
8ø
10ø
8ø
10ø
8ø8ø 8ø
10ø
8ø
8ø
10ø
12x12
8ø10ø
8ø
8ø
8ø
10ø
6ø
8ø
8ø
8ø
10ø 8ø
6ø
10ø
8ø
10ø
12x8
6ø
8ø
6ø 10ø
12ø
40x2024x3234x36
10ø
8ø
8ø 8ø10ø
8ø
8ø
10ø
10ø
8ø
8ø
6ø10ø
8ø
8ø
10ø
10ø
8ø
10ø
10ø
8ø
8ø
12x8
8ø
12x12
16x10
40x26
10ø
EF3-1
18x12
14x8
10x10
12x12
20x1820x18
14x12
14x10
16x12
12x12
10x812x12
16x14
10x10
14x1210x10
10x8
10x10
10x1014x12
10x8
16x1214x12
12x12
20x16
12x10
8ø
40x30
12x10
30x20
44x26
20x18 20x18
18x14
10ø
18x18
20x12
8x8
12x10
14x10
6ø 6ø
12ø 12ø
16x6
22x16
30x18
12x12
30x20
12ø
16x1018x14
32x24
8ø
10x1032x24
20x1810ø
16x14 12x88ø
8ø8ø8ø
8x8 8ø
6ø6ø
6ø
10ø
8ø
6ø
8x8
8ø
8ø
10ø
12x1212x12
8ø12x6
10ø
12x12
10ø
16x12
8ø
10ø10x10
8ø
10ø
8ø
10ø 8ø
20x12
8ø
8ø
8ø8ø
10ø 10ø
10ø
14x12
10ø10x8
10ø
16x10
8ø 8ø
12ø
EG-A, 8X8
(120), TYP-3
EG-A, 8X8
(120)
EG-A, 8X8(120)
EG-B, 8X8(70), TYP-2
EG-A, 8X8(120), TYP-2
EG-A, 8X8
(120), TYP-2
EG-A, 8X8(70), TYP-2
16x14
6ø
12x12
12ø
10ø
8ø10ø
8ø
8ø
8ø
8ø
8ø
CD-A
(110)
CD-B, 8X8(50), TYP-3
CD-B, 8X8(70), TYP-2
CD-A(75)
RG-A(75)
CD-A(75), TYP-2
FPB3-9
FCU3-1
FCU3-3
FCU3-2
FCU3-4
14x10
CD-B, 8X8(60), TYP-2
CD-B, 8X8(180)
EG-B, 8X8(220)
CD-B, 8X8
(40). TYP-4
CD-A,(160)
RG-A(260)
8ø
12x8
RG-B, 16X16(500), TYP-2
26x1
6
FSD-3-1
FSD-3-2
FSD-3-3
FSD-3-4
FSD-3-5
FSD-3-6
FSD-3-7
FSD-3-8
46x3412x10
SG-A, 36X20
(2700)
SG-A, 36X21(2700)SG-A, 36X22
(2700)
SG-A, 36X23
(2700)
12ø
SP1
SA2
SA4
SP2
SP3
SA3
SA1
TX1
SP4
16x16
CD-A(45), TYP-4
6ø
6ø
CD-A(30)
CD-A(50)
EG-A, 8X38
(450), TYP-3
11 1
EG-A, 8X44(450), TYP-3
EG-A, 8X41
(450), TYP-3
EG-A, 8X48(450), TYP-3
1
2
20x1420x14
20x14
6ø
14x10
20x14
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
20:1
4 P
M
05.22.2015
1309100
MH103
NEW SNOHOMISHCOUNTYCOURTHOUSE
CSG
ZMS
MECHANICALFLOOR PLAN -LEVEL 3
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
SHEET NOTES NUMBERED NOTES1 LOW RETURN IN COURT ROOM WITH CONTINUOUS LINEAR GRILL AND ACCOUSTICAL ELBOW.
FCU SERVING THE IDF ROOM WILL BE PROVIDED WITH MIXING BOX AND DUCTED OUTSIDE AIR LUUVRES W/4.0SF OF NFA.
FCU SERVING THE SHERIFF'S OFFICE WILL PROVIDE 24/7 HVAC W/ MIXING BOX AND ECONOMIZER DAMPERSCONNECTED TO OA INTAKE HOODS ON THE LEVEL 3 ROOF.
2
2
3
3
1. THERMOSTAT LOCATION TO BE COORDINATED W/ ARCH. ONE THERMOSTAT PER BOX.2. CARBON DIOXIDE CONTROL VENTILATION IN ALL COURTROOMS & MEETING ROOMS.3. PROVIDE FLEX DUCT CONNECTIONS TO ALL SUPPLY DIFFUSERS AT A MAXIMUM LENGTH OF 5FT.
VAV4-1
VAV4-2
VAV4-3
VAV4-4
VAV4-6
VAV4-7
VAV4-8
VAV4-5
FPB4-13
FPB4-16
FPB4-12
FPB4-17
FPB4-2
FPB4-7
FPB4-8
FPB4-19
FPB4-10
FPB4-18
FPB4-11
FPB4-14
FPB4-21
FPB4-15
36x24
32x16
18x12 20x14
14x10
26x1820x14 18x12
35x20
35x20
10x10
10x8
8x6
26x16
14x10
26x16
30x20
30x20
14x10
26x16
26x16
10ø
8ø
8ø
8ø
8ø 10x6 10x8
6ø
8ø
8ø
16x12 12x6
20x14
20x14
20x12
14x10
45x25
8ø
8ø
10ø8ø 12ø
10ø8ø
8ø
8ø
18x12
14x8 16x12
20x18
10ø
30x18
22x12
45x25
20x18 20x18
30x1820x16
26x18
ELEV.E5
ELEV.E8
STAIRST4-4
STAIRST5-4
ELEV.E3
STAIRST2-4
SHAFTE8
SHAFTS1
S.CELL4-B14
S. CELL4-A14
STND TRIALCOURTROOM
4-A00STND TRIAL
COURTROOM4-B00
STND TRIALCOURTROOM
4-C00
ELEV.E1
CORR.4-407Z
JURY DELIB.4-462
W. TOILET4-010
SEC VEST4-A10
S. CELL4-C14
S. CELL4-D14
JUDICIALOFFICE4-453
SOUNDLOCK4-411Z
JUDICIALOFFICE4-452
WRK/ FILE/STOR/ SERV
UNIT4-451 TOILET
4-463
FURN. STOR.4-457
JURY DELIB.4-422
SOUNDLOCK4-401Z
JUDICIALOFFICE4-431
JUDICIALOFFICE4-432
EVID STOR4-408EVID STOR
4-405A/V ROOM
4-409
SEC VEST4-C10
N-C INT.4-D11
N-C INT.4-C11
M. TOILET4-012
N-C INT.4-A11
OPENOFFICE4-450
OPENOFFICE4-430
TECH EQUIP4-407
TECH EQUIP4-406
ELEC.4-458
N-C INT.4-B11
SEC VEST4-B10
TOILET4-423
TOILET4-421
SOUNDLOCK4-420
EVID STOR4-402
ELEC.4-424
WRK/ FILE/STOR/ SERV
UNIT4-433
A/V ROOM4-401
SERV./PRIVATE
ELEV.LOBBY4-411
PUBLICELEV.
LOBBY4-002
CRT REP4-404
SEC. ELEV.ALCOVE
4-A17
OFF. STAT.4-A13 OFF. STAT.
4-C13
SEC. ELEV.ALCOVE
4-C17
TOILET4-461
SOUNDLOCK4-460
N-C INT.4-D12
N-C INT.4-A12
WAITING4-001
WAITING4-005
EVID STOR4-456
N-C INT.4-B12
N-C INT.4-C12
ATTY. INT.4-B01
SOUNDLOCK4-B05
SOUNDLOCK4-A05
SOUNDLOCK4-C05
ATTY. INT.4-C02
SOUNDLOCK4-D05
ATTY. INT.4-D01
ATTY. INT.4-A01
STAFFTOILET4-403
TOILET4-441
JURY DELIB.4-442
TOILET4-432A TOILET
4-452A
STOR4-433A
TOILET4-443
IDF4-434
SOUNDLOCK4-440
STAFFTOILET4-410
TOILET4-431A
TOILET4-453A
FILES4-454
ELEC.4-455
STOR.4-011
VICT/ WITWAITING
4-C01ATTY HOTEL4-B02
STAIRST3-4
CORR.4-004Z
SEC VEST4-D10
WAITING4-006
WAITING4-004
WAITING4-003
VEST4-008
VEST4-408Z
CORR.4-C00Z
VEST4-405Z
CORR4-402Z
STND TRIALCOURTROOM
4-D00
ELEV.E2
ELEV.E6
ELEV.E7
SHAFTS3
STOR4-451A
24x12
24x12
12x8
8x8
10x8
10x68ø
10x6
8x8
10x8
FPB4-1
FPB4-20
FPB4-22
20x14
18x12
20x1414x12 18/12 20x14
12ø
FPB4-5
18x12
8x8 10x10 12x12
20x14
20x14
10ø
10x6
8x8
20x14
12ø
LD-B, 4'
(400), TYP-5LD-B, 4'(400), TYP-5
LD-B, 4'
(400), TYP-5
LD-B, 4'
(400), TYP-5
LD-A, 2'(175), TYP-4
LD-A, 2'(175), TYP-4
14x12
10x8
18x12
LD-B, 5'
(500), TYP-2
LD-A, 3(300)
RG-B, 4'
(500)
20x1220x12 12x12
20x12
12x12
EF4-1
EF4-2
RG-B, 4'(530), TYP-15
10x10
LD-A, 2'(200), TYP-4
LD-A, 3'(300)
RG-B, 4'(530), TYP-214x10
18x12
10x10
10ø
10ø
10ø
10x1014x12
LD-B, 5'
(500), TYP-2
LD-A, 3'(300)
RG-B, 4'
(500)
18x12
10x10
10ø
10ø
10x10
LD-A, 3'
(300)
LD-B, 5'(500), TYP-2
LD-A, 2'(200), TYP-4
CD-A(230), TYP-2
CD-A(150)
CD-A(100)
CD-A
(110), TYP-2
CD-A
(150), TYP-2
CD-A(110), TYP-2
CD-A(180), TYP-2
CD-A(110), TYP-2
CD-A(150), TYP-2
CD-A
(90), TYP-2
CD-A(200), TYP-2
CD-A(140)
CD-A(100)
CD-A(140)
CD-A(80)
CD-A(200)CD-A
(50)
LD-B, 3'(300), TYP-2 LD-B, 3'
(300), TYP-2
FPB4-9
FPB4-9
8ø8ø
10ø8ø
8ø
8ø
10x8 10x8
FPB4-3
10ø
6ø
8x812x12
6ø
8x8
18x12
24x1220x14
12x12
10x10
10ø10ø
8x8
8ø
18x1218x12
12ø12ø
12x12
12ø12ø
14x12 20x14
8ø
12x12
10ø
10x10
8x8
10ø 10ø
8ø
12ø 12ø 12ø 12ø 12ø
8ø
12x12
10x10
10ø10ø
8x8
20x18
16x12
10x8
10x8
8ø
8x8
8x8
8x8
12x8
12x8
8ø
12x8
10ø 8ø
8ø
6ø10ø
6x6
6x6
10ø
8ø6x6
10x6
10x68ø
8ø
12x810ø
12x8
8ø
RG-B, 4'(500), TYP-2
1 1.1 2 3 4 5 6 6.9 7 8
A
B
C
D
E
F
F.5
6.15.25.14.24.13.23.12.22.11.61.4
1M-301
RG-A(150)
RG-A
(450)
RG-A(220) RG-A
(300)
RG-A(220)
RG-A(100)
RG-A(400)
EG-A, 8X8
(100)
RG-A(220)
RG-A
(300)
RG-A
(220)RG-A(400)
RG-A(250)
20x14
FCU4-1
EG-A, 8x8
(120)
EG-A, 8x8
(120)
EG-A, 8x8(120)
EG-B, 8X8(70), TYP-2
EG-A, 8x8(120)
EG-A, 8x8
(120)EG-A, 8x8(120)
EG-A, 8x8
(120)
EG-A, 8x8(120)
EG-A, 8x8(120)
EG-A, 8x8(120)
EG-A, 8x8(120)
EG-B, 8x8(70), TYP-2
EG-A, 8x8(120)
CD-B, 8X8(60), TYP-2
CD-B, 8X8
(40), TYP-4
CD-A(120)
RG-A(260)
CD-A
(75)
RG-A(75)
CD-A
(70), TYP-2CD-A
(70), TYP-2
RG-A
(70), TYP-2
RG-A
(70), TYP-2
CD-A(70)
RG-A(70)
RG-A(260)
CD-B, 8X8
(40), TYP-4
CD-A
(100)LD-B, 5'(500), TYP-2
12x8
EG-A, 16X16(500), TYP-2
26x1
6
FSD-4-1
FSD-4-2
FSD-4-3
FSD-4-5
FSD-4-4
FSD-4-6
FSD-4-7FSD-4-8
EF4-2
EF4-3SP
1
SA2
SA4
SA1
SA3
SP3
TX1
SP4
SP2
6øCD-A, 12X12(40)
CD-A, 12x12(40)
CD-A, 12x12(40)
CD-A, 12x12(40)
6ø
6ø
CD-A, 12x12
(50)
CD-A, 12x12
(40)
16x16
8ø
IH4-1
RH4-1
11
RG-B, 4'(450), TYP-3
RG-B, 4'(450), TYP-3
RG-B, 4'(450), TYP-3
1
2
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
20:2
5 P
M
05.22.2015
1309100
MH104
NEW SNOHOMISHCOUNTYCOURTHOUSE
CSG
ZMS
MECHANICALFLOOR PLAN -LEVEL 4
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
NUMBERED NOTES1 LOW RETURN IN COURT ROOM WITH CONTINUOUS LINEAR GRILL AND
ACCOUSTICAL ELBOW.
FCU SERVING THE IDF ROOM WILL BE PROVIDED WITH MIXING BOXES ANDDUCTED OUTSIDE AIR LOUVRES W/ 4.0SF OF NFA.
2
2
SHEET NOTES1. THRMOSTAT LOCATION TO BE COORDINATED W/ ARCH. ONE THERMOSTAT PER BOX.2. CARBON DIOXIDE CONTROL VENTALATION IN ALL COURTROOMS & MEETING ROOMS.3. PROVIDE FLEX DUCT CONNECTIONS TO ALL DIFFUSERS AT A MAXIMUM LENGTH OF 5FT.
ELEV.E5
STAIRST4-5
ELEV.E7
STAIRST5-5
STAIRST2-5
STAIRST3-5
SHAFTS2
SHAFTS1 S.CELL
5-B14S. CELL
5-A14
STND TRIALCOURTROOM
5-A00
STND TRIALCOURTROOM
5-B00
STND TRIALCOURTROOM
5-C00
ELEV.E1
JURY DELIB.5-462
W. TOILET5-010
SEC VEST5-A10
ELEV.E3
S. CELL5-C14
S. CELL5-D14
SEC VEST5-D10
JUDICIALOFFICE5-453
SOUNDLOCK5-415Z
JUDICIALOFFICE5-452
WRK/ FILE/STOR/ SERV
UNIT5-451 TOILET
5-463
FURN. STOR.5-457
JURY DELIB.5-422
SOUNDLOCK5-401Z
JUDICIALOFFICE5-431
JUDICIALOFFICE5-432
EVID STOR5-408EVID STOR
5-405
A/V ROOM5-409
SEC VEST5-C10
N-C INT.5-D11
N-C INT.5-C11
M. TOILET5-012
N-C INT.5-A11
OPENOFFICE5-450
OPENOFFICE5-430
TECH EQUIP5-407
TECH EQUIP5-406
ELEC.5-458
N-C INT.5-B11
SEC VEST5-B10
TOILET5-423
TOILET5-421
SOUNDLOCK5-420
EVID STOR5-402
ELEC.5-424
WRK/ FILE/STOR/ SERV
UNIT5-433
A/V ROOM5-401
SERV./PRIVATE
ELEV.LOBBY5-411
PUBLICELEV.
LOBBY5-002
CRT REP5-404
SEC. ELEV.ALCOVE
5-A17
OFF. STAT.5-A13
OFF. STAT.5-C13
SEC. ELEV.ALCOVE
5-C17
TOILET5-461
SOUNDLOCK5-460
N-C INT.5-D12
N-C INT.5-A12
N-C INT.5-B12
N-C INT.5-C12
ATTY. INT.5-B01
SOUNDLOCK5-B05
SOUNDLOCK5-A05
SOUNDLOCK5-C05
ATTY. INT.5-C02
SOUNDLOCK5-D05
ATTY. INT.5-D01
ATTY. INT.5-A01
STAFFTOILET5-403
TOILET5-441
JURY DELIB.5-442
TOILET5-432A
TOILET5-452A
STOR5-433A
TOILET5-443
IDF5-434
SOUNDLOCK5-440
STAFFTOILET5-410
TOILET5-431A
FILES5-454
ELEC.5-455
STOR.5-011
VICT/ WITWAITING
5-C01ATTY HOTEL
5-B02
CORR.5-004Z
ELEV.E8
WAITING5-006
WAITING5-005
WAITING5-004
WAITING5-003
WAITING5-001
VEST5-008
SOUNDLOCK5-402Z
VEST5-408Z
CORR.5-C00Z
VEST5-405Z
TOILET5-453A
EVID STOR5-456
LG TRIALCOURTROOM
5-D00
ELEV.E2
ELEV.E6
CORR.5-407Z
SHAFTS3
STOR5-451A
1 1.1 2 3 4 5 6 6.9 7
A
B
C
D
6.15.25.14.24.13.23.12.22.11.61.4
VAV5-1
VAV5-2
VAV5-3
VAV5-4
VAV5-6
VAV5-7
VAV5-8
VAV5-5
FPB5-13
FPB5-20
FPB5-12
FPB5-21
FPB5-2
FPB5-7
FPB5-8
FPB5-19
FPB5-10
FPB5-18
FPB5-11
FPB5-15
FPB5-13
FPB5-14
44x40
32x16
18x12 20x14
14x10
26x1820x14 18x12
35x20
35x20
10x10
16x12
10x8
8x6
26x16
14x10
26x16
30x20
30x20
14x10
26x16
26x16
10ø
8ø
8ø8ø 10x6 10x8
6ø
8ø14x8
8ø
16x12 12x6
20x14
20x14
20x12
14x10
45x25
8ø
8ø
10ø8ø 12x6
10ø8ø
8ø
8ø
18x12
14x8 14x8 16x12
20x18
32x16
8ø
30x18
22x12
45x2520x18 20x18
30x1820x16
26x18
12x12
24x12
24x12
12x8
8x8
10x8
10x68ø
10x6
8x8
10x8
FPB5-1
FPB5-16
FPB5-22
20x14
18x12
20x1414x12 18/12 20x14
12ø
FPB5-5
12x12
18x12
8x8 10x10 12x12
20x14
20x14
20x1410ø
10x6
8x8
20x14
12ø
LD-B, 4'(400), TYP-5
LD-B, 4'(400), TYP-5
LD-B, 4'
(400), TYP-5
LD-B, 4'
(400), TYP-5
LD-A, 2'
(175), TYP-4
LD-A, 2'
(175), TYP-4
14x12
10x8
18x12
LD-B, 5'
(500), TYP-2
LD-A, 3'(300)
RG-B, 4'(500)
20x12 20x1212x12
20x12
12x12
EF5-1
EF5-2
RG-B, 4'
(530), TYP-15
10x10
LD-A, 2'(200), TYP-4
LD-A, 3'(300)
RG-B ,4'(530), TYP-2
14x10
18x12
10x10
10ø
10ø
10ø
10x1014x12
LD-B, 5'
(500), TYP-2
LD-A, 3'(300)
RG-B, 4'
(500)
18x12
10x10
10ø
10ø
LD-A, 3'
(300)
LD-B, 5'(500), TYP-2
LD-A, 2'(200), TYP-4
CD-A
(230), TYP-2
CD-A(150)
CD-A(100)
CD-A(110), TYP-2
CD-A(150), TYP-2
CD-A
(110), TYP-2
CD-A(180), TYP-2
CD-A
(110), TYP-2CD-A(150), TYP-2
CD-A
(90), TYP-2
CD-A(200), TYP-2
CD-A(140)
CD-A(100)
CD-A
(140)CD-A(100)
CD-A(200)
CD-A(50)
LD-B, 3'(300), TYP-2 LD-B, 3'
(300), TYP-2
FPB5-9
FPB5-9
8ø8ø
10ø8ø
8ø
8ø 10x8 10x8
8ø8ø
FPB5-3
10ø
6ø
8x8
12x12
6ø
8x8
18x12
24x1220x14
12x12
10x10
10ø10ø
8x8
8ø
18x1218x12
12ø 12ø12ø 12ø
12x12
12ø12ø12ø12ø12ø
14x12 20x14
8ø
12x12
10ø
10x10
10ø
8x8
10ø 10ø
8ø
12ø 12ø 12ø 12ø 12ø
12x12
10x10
10ø10ø
8x8
20x18
16x12
10x8
10x8
8ø
8x8
8x8
8x8
12x8
12x8
8ø
12x8
10ø 8ø
8ø
6ø10ø
6x6
6x6
10ø
8ø6x6
10x610x68ø
8ø
12x810ø
12x8 8ø
RG-B, 4'(500), TYP-2
RG-A(150)
RG-A,(450)
RG-W(220)
RG-HH
(300)
RG-A,(220)
RG-LL(100)
RG-A(400)
RG-A
(100)
RG-A
(220)
RG-OO(300)
RG-QQ(220)
RG-A(450)
RG-A(250)
FCU5-1
8ø
EG-A, 8X8(120)
EG-A, 8X8(120)
EG-A, 12X12(120)
EG-A, 8X8
(70), TYP-2
EG-A, 8X8(120)
EG-A, 12X12
(120)EG-A, 12X12(120)
EG-A, 12X21(120)
EG-A, 12X12(120)
EG-A, 12X12(120)
EG-A, 8X8(120)
EG-A, 8X8(120)
EG-B, 8x8(70), TYP-2
EG-A, 8X8(120)
CD-B, 8X8(60), TYP-2
CD-B, 8X8(40), TYP-4
CD-A
(120)RG-A(260)
RG-III(75)
RG-A(75)
CD-A(70)RG-A(70)
CD-A(70), TYP-2
CD-A
(70), TYP-2
RG-A(70), TYP-2
RG-A
(70), TYP-2
CD-B, 8X8(40), TYP-4
CD-A(120)
1
LD-B, 5'(500), TYP-2
12x8
EG-A, 16X16(500), TYP-2
26x1
6
FSD-5-1FSD-5-2
FSD-5-3
FDS-5-5
FSD-5-4
FSD-5-6
FSD-5-7FSD-5-8
EF5-2
EF5-3SP
1
SA2
SA4
SA1
SA3
SP3
TX1
SP4
SP2
CD-A, 12x12
(40)CD-A, 12x12(40)
CD-A, 12x15(40)
CD-A, 12x12(40)
6ø
CD-A, 12x12
(50)
CD-A, 12x12
(40)
6ø
16x16
RG-B, 4'-0"(450), TYP-3
11 1
RG-B, 4'-0"(450), TYP-3
RG-B, 4'-0"(450), TYP-3
RG-B, 4'-0"(450), TYP-3
2
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
20:3
5 P
M
05.22.2015
1309100
MH105
NEW SNOHOMISHCOUNTYCOURTHOUSE
CSG
ZMS
MECHANICALFLOOR PLAN -LEVEL 5
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
NUMBERED NOTES1 LOW RETURN IN COURT ROOM WITH CONTINUOUS LINEAR GRILL AND ACCOUSTICAL
ELBOW.
FCU SERVING THE IDF ROOM WILL BE PROVIDED WITH MIXING BOXES AND DUCTEDOUTSIDE AIR LOUVRES W/ 4.0SF OF NFA.
2
2
SHEET NOTES1. THRMOSTAT LOCATION TO BE COORDINATED W/ ARCH. ONE THERMOSTAT PER BOX.2. CARBON DIOXIDE CONTROL VENTALATION IN ALL COURTROOMS & MEETING ROOMS.3. PROVIDE FLEX DUCT CONNECTIONS TO ALL DIFFUSERS AT A MAXIMUM LENGTH OF 5FT.
S.CELL6-B14
S. CELL6-A14
LG TRIALCOURTROOM
6-D00
STND TRIALCOURTROOM
6-A00
STND TRIALCOURTROOM
6-B00
STND TRIALCOURTROOM
6-C00
STAIRST4-6
ELEV.E5
ELEV.E2
CORR.6-407Z
JURY DELIB.6-462
W. TOILET6-010
SEC VEST6-A10
ELEV.E3
ELEV.E8
STAIRST5-6
S. CELL6-C14
S. CELL6-D14
SEC VEST6-D10
JUDICIALOFFICE6-453
SOUNDLOCK6-415Z
JUDICIALOFFICE6-452
WRK/ FILE/STOR/ SERV
UNIT6-451
TOILET6-463
FURN. STOR.6-457
JURY DELIB.6-422
SOUNDLOCK6-401Z
JUDICIALOFFICE6-431
JUDICIALOFFICE6-432
EVID STOR6-405
A/V ROOM6-409
SEC VEST6-C10
N-C INT.6-D11
N-C INT.6-C11
M. TOILET6-012
N-C INT.6-A11
OPENOFFICE6-450
OPENOFFICE6-430
TECH EQUIP6-407
TECH EQUIP6-406
ELEC.6-458
ELEV.E6
N-C INT.6-B11
SEC VEST6-B10
TOILET6-423
TOILET6-421
SOUNDLOCK6-420
EVID STOR6-402
ELEC.6-424
WRK/ FILE/STOR/ SERV
UNIT6-433
A/V ROOM6-401
SERV./PRIVATE
ELEV.LOBBY6-411
PUBLICELEV.
LOBBY6-002
CRT REP6-404
SEC. ELEV.ALCOVE
6-A17
OFF. STAT.6-A13
OFF. STAT.6-C13
SEC. ELEV.ALCOVE
6-C17
TOILET6-461
SOUNDLOCK6-460
SHAFTS2
SHAFTS1
N-C INT.6-D12
N-C INT.6-A12
CORR.6-004Z
WAITING6-006
STAIRST2-6
STAIRST3-6
N-C INT.6-B12
N-C INT.6-C12
ATTY. INT.6-B01
SOUNDLOCK6-B05
SOUNDLOCK6-A05
SOUNDLOCK6-C05
ATTY. INT.6-C02
SOUNDLOCK6-D05
ATTY. INT.6-D01
ATTY. INT.6-A01
STAFFTOILET6-403
TOILET6-441
JURY DELIB.6-442
TOILET6-432A
TOILET6-452A
STOR6-433A
TOILET6-443
IDF6-434
SOUNDLOCK6-440
STAFFTOILET6-410
TOILET6-431A
FILES/ STOR6-454
ELEC.6-455
STOR.6-011
VICT/ WITWAITING
6-C01
ATTY HOTEL6-B02
CORR6-402Z
WAITING6-001
WAITING6-004 WAITING
6-005
WAITING6-003
VEST.6-008
EVID STOR6-408
VEST6-408Z
VEST6-405Z
CORR.6-C00Z
EVID STOR6-456
SHAFTS3
ELEV.E7
ELEV.E1
TOILET6-453A
STOR6-451A
1 1.1 2 3 4 5 6 6.9 7
A
B
C
D
6.15.25.14.24.13.23.12.22.11.61.4
VAV6-1
VAV6-2
VAV6-3
VAV6-4
VAV6-6
VAV6-7
VAV6-8
VAV6-5
FPB6-13
FPB6-16
FPB6-12
FPB6-17
FPB6-2
FPB6-7
FPB6-8
FPB6-19
FPB6-10
FPB6-18
FPB6-11
FPB6-14
FPB6-21
FPB6-15
44x40
32x16
18x12 20x14
14x10
26x1820x14 18x12
35x20
35x20
10x10
16x12
10x8
8x6
26x16
14x10
26x16
30x20
30x20
14x10
26x16
26x16
10ø
8ø
8ø
8ø
8ø 10x6 10x8
6ø
8ø14x8
8ø
16x1212x6
20x14
20x14
20x12
14x10
45x25
8ø
8ø
10ø12x6
10ø8ø
8ø
8ø
18x12
14x8 14x816x12
20x18
32x16
8ø
30x18
22x12
45x2520x18 20x18
20x16
26x18
12x12
24x12
24x12
12x12
12x8
8x8
10x8
10x68ø
10x6
8x8
10x8
FPB6-1
FPB6-20
FPB6-22
20x14
18x12
20x1414x12 20x14
12ø
FPB6-5
12x12
18x12
10x10 12x12
20x14
20x14
20x1410ø
10x6
8x8
20x14
12ø
LD-B, 4'(400), TYP-5
LD-B, 4'
(400), TYP-5LD-B, 4'
(400), TYP-5
LD-B, 4(400), TYP-5
LD-A, 2'(175), TYP-4
LD-A, 2'
(175), TYP-4
14x12
10x8
18x12
LD-B, 5'(500), TYP-2
LD-A, 3'(300)
RG-B, 4'
(500)
20x12 20x1212x12
20x12
12x12
EF6-1
EF6-2
RG-B, 4'(530), TYP-15
10x10
LD-A, 2'
(200), TYP-4
LD-A, 3'(300)
RG-B, 4'(530), TYP-214x10
18x12
10ø
10ø
10ø
10x1014x12
LD-B, 5'(500), TYP-2
LD-A, 3'(300)
RG-B, 4'
(500)
18x12
10x10
10ø
10ø
10x10
LD-A, 3'(300)
LD-B, 5'(500), TYP-2
LD-A, 2'(200), TYP-4
CD-A
(250), TYP-2
CD-A
(150)
CD-A(50)
CD-A(100)
CD-A(110), TYP-2
CD-A
(150), TYP-2
CD-A(110), TYP-2
CD-A(180), TYP-2
CD-A(110), TYP-2
CD-A(150), TYP-2
CD-A(90), TYP-2
CD-A
(200), TYP-2
CD-A
(140)
CD-A(100)
CD-A(140)
CD-A(100)
CD-A
(200)CD-A(50)
LD-B, 3'(300), TYP-2
LD-B, 3'
(300)
FPB6-9
FPB6-9
8ø8ø
10ø8ø
8ø
8ø10x8
10x88ø
8ø
FPB6-3
10ø
6ø6ø
8x8 6ø
8x8
18x12
24x12
12x12
10x10
10ø10ø
8x8
8ø
18x1218x12
12ø 12ø12ø 12ø
12x12
12ø12ø12ø12ø12ø
14x12 20x14
8ø
12x12
10ø
10x10
10ø
8x8
10ø 10ø
8ø
12ø 12ø
12x12
10x10
10ø
8x8
20x18
16x12
10x8
10x8
8ø
8x8
8x8
8x8
12x8
12x8
8ø
12x8
10ø 8ø
8ø
6ø 10ø
6x6
6x6
10ø
8ø6x6
10x68ø
8ø
12x810ø
12x8 8ø
RG-B, 4'(500)
RG-A(150)
RG-A
(500)
RG-A
(220)
RG-A(300)
RG-A
(50)
RG-A(220)
RG-A(100)
RG-A(400)
RG-A(100)
RG-A(220)
RG-A(300)
RG-A
(220)
RG-A(450)
RG-A(250)
FCU6-1
8øEG-A, 8X8
(120)
EG-A, 8X8
(120) EG-A, 12X12
(120)
EG-B, 8X8(70), TYP-2
EG-A, 8X8
(120)
EG-A, 12X12
(120)
EG-A, 12X12(120)
EG-A, 8X8(120)
EG-A, 8X8(120)
EG-A, 12X12
(120)
EG-A, 12X12(120)
EG-A, 12X12(120)
EG-B, 8X8(70), TYP-2
EG-A, 8x8
(120)
CD-B, 8X8(60), TYP-2
CD-A(120)
CD-B, 8X8(40), TYP-4
RG-A(260)
RG-A(75)
CD-A
(75)
CD-A
(70)RG-A(70)
CD-B, 8X8
(40), TYP-4
CD-A(120)
RG-A
(260)
CD-B, 8X8(60), TYP-2
LD-B, 5'
(500), TYP-2
12x8
RG-B, 16x16(500), TYP-2
26x1
6
FSD-6-2
FSD-6-1
FSD-6-5
FSD-6-4
FSD-6-3
SG-A, 36X24
(2700)
SG-A, 36X25(2700)
SG-A, 36X26(2700)
SG-A, 36X20
(2700)
EF6-2
EF6-3SP
1
SA2
SA4
SA1
SA3
SP3
TX1
SP4
SP2
FSD-6-9
FSD-6-7
FSD- 6-8
FSD-6-6
CD-A, 12x12(40)
CD-A, 12x12
(40)
CD-A, 12x12(40)
CD-A, 12x12
(40)
6ø
CD-A, 12x12(50)
CD-A, 12x12
(40)
16x16
RG-B, 4'
(450), TYP-3
11 1
RG-B, 4'(450), TYP-3
RG-B, 4'
(450), TYP-3
RG-B, 4'
(450), TYP-3
2
CD-A
(70), TYP-2CD-A
(70), TYP-2
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
20:4
4 P
M
05.22.2015
1309100
MH106
NEW SNOHOMISHCOUNTYCOURTHOUSE
CSG
ZMS
MECHANICALFLOOR PLAN -LEVEL 6
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
NUMBERED NOTES1 LOW RETURN IN COURT ROOM WITH CONTINUOUS LINEAR GRILL AND
ACCOUSTICAL ELBOW.
FCU SERVING THE IDF ROOM WILL BE PROVIDED WITH MIXING BOXES ANDDUCTED OUTSIDE AIR LOUVRES W/ 4.0SF OF NFA.
2
2
SHEET NOTES1. THRMOSTAT LOCATION TO BE COORDINATED W/ ARCH. ONE THERMOSTAT PER BOX.2. CARBON DIOXIDE CONTROL VENTALATION IN ALL COURTROOMS & MEETING ROOMS.3. PROVIDE FLEX DUCT CONNECTIONS TO ALL DIFFUSERS AT A MAXIMUM LENGTH OF 5FT.
UPFPB7-1
FPB7-14
FPB7-6
FPB7-15
FPB7-13
FPB7-12
FPB7-16FPB
7-17FPB7-11
FPB7-10
FPB7-3
FPB7-19
FPB7-20
FPB7-2
FPB7-21
FPB7-5
FPB7-7
VAV7-5
VAV7-7
VAV7-9
VAV7-8
VAV7-4
VAV7-11
VAV7-2
VAV7-13
VAV7-10
VAV7-1
VAV7-6
VAV7-3
VAV7-12
VAV7-14
VAV7-16
VAV7-15
VAV7-17
SHAFTS2
TRIALNVL/DRG
DEPUTY PA7-256
TRIALNVL/DRGLEAD PA
7-252
TRIALNVL/DRG
DEPUTY PA7-262
APPEALSDEPUTY PA
7-250
TRIALNVL/DRG
DEPUTY PA7-258
TRIALNVL/DRG
DEPUTY PA7-260
TRIALNVL/DRG
DEPUTY PA7-264
TRIALNVL/DRG
DEPUTY PA7-263
TRIALNVL/DRG
DEPUTY PA7-261
APPEALSDEPUTY PA
7-251ADMINSTAFF7-233
INTERN DP7-138
FELONY FILE7-222
OPENOFFICE7-249
TRIALNVL/DRG
DEPUTY PA7-265
CONFERENCEROOM7-202
CONFERENCEROOM7-203
CONFERENCEROOM7-204
NVL/DRGDEPUTY PA
7-135
APPEALSDEPUTY PA
7-137
NVL/DRGDEPUTY PA
7-142
NVL/DRGLEAD DEP
PA7-143
NVL/DRGDEPUTY PA
7-145
NVL/DRGDEPUTY PA
7-146
NVL/DRGDEPUTY PA
7-147
NVL/DRGDEPUTY PA
7-139
DISTRICTADVOCATE /
PL7-149
DISTRICTDEPUTY PA
7-210
DISTRICTDEPUTY PA
7-209
DISTRICTDEPUTY PA
7-208
DISTRICTDEPUTY PA
7-207
DISTRICTDEPUTY PA
7-206
DISTRICTDEPUTY PA
7-220
DISTRICTDEPUTY PA
7-221
DISTRICTDEPUTY PA
7-223
DISTRICTDEPUTY PA
7-225
DISTRICTDEPUTY PA
7-227
INTERN DP7-255
LEADDISTRICT
DEPUTY PA7-212
ELEC.7-237
SHAFTS1
ELEC.7-120
STAIRST4-7
COPY/FILES/WORK7-236
OPS CHIEF7-243
CHIEFDEPUTY PA
7-128
DISTRICTADVOCATE /
PL7-211
APPEALSDEPUTY PA
7-235
COPY/FILES/WORK7-108
PUBLICWAITING
7-003
INTERN DP7-125
STAIRST2-7
VIOLENT/DVDEPUTY PA
7-118
VIOLENT/DVLEAD
DEPUTY PA7-117
VIOLENTLEAD
DEPUTY PA7-115
VIOLENT/DVDEPUTY PA
7-114
VIOLENT/DVDEPUTY PA
7-110
VIOLENTDEPUTY PA
7-106
VIOLENTDEPUTY PA
7-105
VIOLENTDEPUTY PA
7-103
VIOLENTDEPUTY PA
7-101
VIOLENTDEPUTY PA
7-102
VIOLENTCRIMINAL
MGR7-104
VIOLENT/DVDEPUTY PA
7-112
VIOLENT/DVADV / PL
7-129
VIOLENT/ADVOCATEPARALEGAL
7-141
RECEPTIONWORK AREA
7-201
PUBLICELEV.
LOBBY7-002
COPY/FILEAREA7-116
PROSECUTOR7-245
CRIMINALMGR7-113
CRIMINALADVOCATE /
PL7-234
W. TOILET7-010
SERVICEDOG STOR.
7-127
CRIMINALADVOCATE /
PL7-232
APPEALSCHIEF
DEPUTY PA7-254
STOR.7-242
DUI/MHCOURT DPA
7-230
DUI/MHCOURT DPA
7-231
CORR./SERV. UNIT
7-222Z
CRIMINALMGR7-205
OPENOFFICE7-126
STAIRST3-7
M. TOILET7-012
TRIALNVL/DRG
DEPUTY PA7-253
DISTRICTDEPUTY PA
7-148
ELEV.E6
SERV./PRIVATE
ELEV.LOBBY7-121
STOR.7-241
ELEC.7-240
CORR.7-120Z
ELEV.E1
ELEV.E3
CORR.7-001Z
CORR.7-004Z
VIOLENT/DVADV / PL
7-111
VIOLENT/ADVOCATEPARALEGAL
7-140
DISTRICTFILES7-151A
OPENOFFICE7-150
OFFSITEATTORNEY
PROSECUTING/ SERV. UNIT
7-013
FELONY FILE7-224
IDF7-130
STOR.7-011
CORR.7-008
408 SFOPEN OFFICE
226 SF9.141,9.122,9.124
OPENOFFICE7-151
CORR.7-101Z
OPENOFFICE7-107
CORR./SERV. UNIT
7-140Z
CORR.7-130Z
CORR.7-234Z
CORR.7-257Z
OPENOFFICE7-257
ELEV.E2
ELEV.E7
SHAFTS3
12x8
8ø
8ø
8ø
FPB7-8
FPB7-18
26x14
FPB7-9
20x14
12x8
8ø
14x12
12x8
8ø
18x14 8x6
10ø
16x10
10x1010x10
10x10
8ø
8ø
12x10
8ø10x10
24x20
12x12
10x12
12x12 8ø
8ø
6ø
8x8
20x14
FPB7-4
CD-A(150), TYP-3
CD-A(180), TYP-2
CD-A
(70), TYP-2
CD-A(125), TYP-2
CD-A(50), TYP-4
CD-A(130), TYP-2
CD-A(50), TYP-6
CD-A
(60), TYP-3
CD-A(110), TYP-3
CD-A
(30)CD-A
(90)
CD-A
(55), TYP-5
CD-A(140), TYP-2
CD-A(120)
CD-A(150)
CD-A(250)
CD-A(200)
CD-A(160)
CD-A(180)
CD-A
(110), TYP-2
CD-A(135), TYP-3
CD-A(135), TYP-3
CD-A(60), TYP-2
CD-A(80)
CD-A(100)
CD-A
(50), TYP-4
CD-A(50), TYP-6CD-A
(100), TYP-2
CD-A
(85), TYP-2
LD-B(425), TYP-4
16x10
1 1.1 2 3 4 5 6 6.9 7
A
B
C
D
6.15.25.14.24.13.23.12.22.11.61.4
RG-A
(150), TYP-3
CD-A(135), TYP-3
RG-A(130), TYP-3
CD-A(135), TYP-3
RG-A(130), TYP-3
CD-A
(150)
RG-A(150)
RG-A
(100), TYP-2
RG-A
(50), TYP-3
CD-A
(55), TYP-3
CD-A
(50)
CD-A
(150), TYP-2
RG-A
(300)
CD-A
(150)
CD-A
(100)
RG-A(150)
RG-A
(100)
CD-A
(150)
RG-A
(150)
CD-A(120)
LD-B, 4'
(400)
LD-B, 2'
(150)
LD-B, 3'
(250)
RG-B, 4'
(400), TYP-2
RG-A(50), TYP-6
RG-A(250), TYP-2
RG-A
(120)
RG-A(130), TYP-3
RG-A
(60), TYP-3
RG-A(130), TYP-3
RG-A(180)
RG-A
(160)
RG-A(150)
RG-A(250)
RG-A
(200)
RG-A
(120)RG-A
(55), TYP-5
RG-A(280)
RG-A(50)
RG-A
(150)CD-A(150)
RG-A
(300), TYP-2
FCU7-1
FCU7-2
EF7-1
6ø
6ø
10ø
6ø
8ø
8ø
6ø
6ø8ø
6ø
8ø
8ø12x12 10ø
12x10
8x8
8ø 8ø
8ø
6ø
6ø
10x10
6ø
8ø
10ø
8ø
8ø
8ø
10ø
10ø
26x14
6ø
6ø
6ø
12x10
8ø
8ø
10ø
6ø
6ø
6ø
8ø
12x10
8ø8x8
12x10
6ø
8ø
12x12
6ø
12x106ø
8ø
8x8
6ø
10ø 6ø 6ø 6ø 6ø 12x108x8 12x12
8ø
8ø
8ø
6ø
10x106ø
10ø
10ø
6ø
8ø
8ø
10ø 10x10
6ø8ø
12x12
8ø
8ø
8ø
8ø
6ø
6ø 6ø
10ø
8ø
8ø
8ø
8ø
6ø
6ø
8ø
20x14
8ø
8ø
10x10
8ø
8ø
6ø
8ø 6ø6ø8ø12x10
22x14
20x14
12x8
EG-A, 16X16(500), TYP-2
26x1
6
FSD-7-1
FSD-7-3
FSD-7-2
FSD-7-4FSD-7-7
FSD-7-5
SP1
SA2
SA1
SP3
TX1
SP4
SP2
SA4
SA3
16x16
2
CD-A(50), TYP-4
40x2036x20
EG-A, 8X8(100)
6ø
10ø
10ø
ER-A, 8x8
(40)
EG-A, 12X12(100)
EG-A, 12X12
(100)
CD-A, 12x12
(60)
6ø
CD-A, 12x12
(40)
6ø
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
20:5
4 P
M
05.22.2015
1309100
MH107
NEW SNOHOMISHCOUNTYCOURTHOUSE
CSG
ZMS
MECHANICALFLOOR PLAN -LEVEL 7
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
NUMBERED NOTESNOT USED
FCU SERVING THE IDF ROOM WILL BE PROVIDED WITH MIXING BOXES AND DUCTEDOUTSIDE AIR LOUVERS W/ 4.0SF OF NFA.
1
SHEET NOTES1. THRMOSTAT LOCATION TO BE COORDINATED W/ ARCH. ONE THERMOSTAT PER BOX.2. CARBON DIOXIDE CONTROL VENTALATION IN ALL COURTROOMS & MEETING ROOMS.3. PROVIDE FLEX DUCT CONNECTIONS TO ALL DIFFUSERS AT A MAXIMUM LENGTH OF 5FT. 2
UP
FPB8-4
FPB8-6
FPB8-2
FPB8-11
FPB8-13
FPB8-18
FPB8-3
FPB8-14
FPB8-15
FPB8-12
VAV8-1
VAV8-13
VAV8-12
VAV8-2
VAV8-4
VAV8-11
VAV8-5
VAV8-7
VAV8-9
VAV8-10
VAV8-8
VAV8-6
VAV8-3
FPB8-7
FPB8-5
FPB8-8
ELEV.E1
W. TOILET8-010
M. TOILET8-012
SHAFTS2
STAIRST2-8
ELEC.8-255
STAIRST3-8
VEST8-008
IDF8-228
SHAFTS1
ELEV.E3
STAFFTOILET8-132
STAFFTOILET8-131
SUPPLIES8-203
FISCALFILE/STOR
8-207
STORAGE8-203A
S-OPS LT8-205
RECEPTION/ADMIN8-202
FINANCEMGR8-208
VOLDIRECTOR
8-217
FINANCEMGR8-209
PUBLICAFFAIRS
8-243
LET LEAD8-204
RSO FILES8-269
SECURE RPTFORMSSTOR8-253
INVEST.SUPPLY/STORAGE
ROOM8-270
MCURECORDS
8-262
EVIDENCEPROCESS
8-261
CONFERENCEROOM8-252S-OPS
CAPTAIN8-230
CAPT OFINVEST8-254
SHERIFF8-233
UNDERSHERIFF8-236
BUREAUCHIEF
PUBLICDISCL8-234
ODDCAPTAIN
8-229
BUREAUCHIEF ODD
DEP8-235
MCUBULLPEN
8-260
INVESTLIEUTENANT
8-280
OPA SGT 18-282
OPA SGT 28-284GEN INVST
SGT8-285
MCU SGT8-283
VOL WORK8-281INT RM
8-266INT RM8-267
POLYGRAPHINT/TEST
8-268
SUPPLY/STOR.ROOM8-244
FEMALELOCKERS
8-287
MALELOCKERS
8-286
ODD SGT8-214
ODD SGT8-215
ODD LT LETLEAD8-216
NON-SECSTOR8-225
KINARDCONFERENCE
ROOM8-226
CORR.8-225Z
CONF8-130
SM JUDICIALMTG8-125
OPENOFFICE8-231
CLOS.8-263
PUBLICELEV.
LOBBY8-002
RECEPTION/WAIT8-201
ELEV.E8
STORAGE/WORK RM
8-251
DRY CLEAN8-011
SHAFTS1
CT ADMNCONF8-111
FILES8-106
RECEPTIONWAITING
8-101
SUPPORT8-104
WORK/ MAIL8-105
LARGEJUDICIAL
CONF8-102
STOR8-102A
ASST.COURTADMIN.8-115
COURTADMINISTRATOR
8-114
CASE FLOWMANAGER
8-113
BUS.ANALYST
8-112
STAFF SRVCUNIT8-103
STOR.8-117
STOR.8-227
OPEN WORKAREA8-110
CORR8-130Z
CORR8-110Z
CORR8-112Z
CORR8-117Z
SERV./PRIVATE
ELEV.LOBBY8-121
ELEC.8-118
OPENOFFICE8-219
CORR8-242Z
OPENOFFICE8-242
OPENOFFICE8-206
CORR8-210Z
CORR8-203Z
CORR8-215Z
CORR8-230Z
CORR8-280Z
CORR8-285Z
SHAFTS3
CORR8-002Z
CORR8-001Z
TOILET8-150
FISCALFILE/STOR
8-210
CORR8-235Z
CLOS.8-130A
BUREAUCHIEF TECH
SUPPORT8-232
STAIRST4-8
ELEV.E6
ELEV.E2
ELEV.E7
CORR8-101Z
COLLABORATIONAREA8-288
12ø
10ø
10ø
6ø
8ø
12ø
8x8
12x10
10ø
8ø
8ø10x8
10ø
14ø
18x12
12x108ø
6ø
6ø
16x12
8ø8ø
18x12
8ø
10ø
8ø
10ø
8ø
8ø 8ø
10ø
10ø
12ø
8ø
8ø
6ø
6ø
6ø
6ø
6ø
6ø
6ø
6ø
16x1212x10
12x10
18x10
6ø10ø
8ø
6ø
14ø
8ø
8ø
10ø
10ø
6ø
6ø
8ø
12x10
6ø
10ø
6ø
12ø
FPB8-10
12ø
8ø
10ø
8ø
10ø
8ø
VAV8-14
FPB8-9
FPB8-17
6ø
8ø8ø
10ø
10x10
12x12
12ø
FPB8-1
12x12
10ø
12ø
8ø
8ø
18x14
24x16
18x1
0
12x12
8ø 10x88ø 10ø
12x12
8ø 10ø
12x12
8ø
10ø
6ø
12x12
8ø
CD-A(175), TYP-2
CD-A(120)
CD-A(150), TYP-2
CD-A(150), TYP-2
CD-A
(75), TYP-2
CD-A(160), TYP-2
CD-A(75), TYP-2
CD-A(200)
CD-A(120), TYP-2
CD-A(160)
CD-A(50)
CD-A(100)
CD-A(130), TYP-4
CD-A
(200), TYP-2
CD-A(135), TYP-3
CD-A(150)
CD-A
(40)
CD-A(70), TYP-3
CD-A(60), TYP-3
CD-A(40)
CD-A(130), TYP-4
LD-B(390)
LD-B(170), TYP-3
LD-B, 4'(250)
CD-A(50)
CD-A(70)
CD-A(60)
CD-A
(70)
CD-A(50)
CD-A(20)
CD-A(150), TYP-2
CD-A(100), TYP-2
CD-A(170), TYP-3
CD-A(200)
CD-A(150)
CD-A(125), TYP-4
CD-A(100)
CD-A
(100)
CD-A(60)
CD-A(70), TYP-3
CD-A(50), TYP-4
CD-A(70)
CD-A
(30)
CD-A(60)
LD-B, 3'(165), TYP-4
LD-B, 3'(180), TYP-5
1 1.1 2 3 4 5 6 6.9 7
A
B
C
D
6.15.25.14.24.13.23.12.22.11.61.4
RG-A
(250), TYP-2
RG-A(70), TYP-3
RG-A(50), TYP-4
RG-A
(350)
RG-A(120)
RG-A(200)
RG-A(150)
RG-A
(170) TYP-3
RG-A(250), TYP-2
RG-A(400)
RG-A(400)
RG-A
(400)
RG-A(750)
EG-A, 8x8
(60)
RG-A(135), TYP-3
RG-A
(70), TYP-3
RG-A(60), TYP-3
RG-A(40)
RG-A(400), TYP-3
RG-A(80)
RG-A(120)
RG-A(120)
RG-A(50)
RG-A(75), TYP-2
RG-A(160), TYP-2RG-A
(225), TYP-2
RG-A
(300)
RG-A(50)
RG-A
(60)
RG-A
(100)
CD-A
(100)
RG-A(60)
8ø
8ø
6ø
RG-A(120), TYP-2
RG-A(200) RG-A
(160)
8ø
8ø
8ø
6ø
6ø
FCU8-1
FCU8-2
CD-A(250)
FPB8-16
RG-A
(60)
RG-A(70)
EG-A, 12x12
(270)
EG-A, 8x8(140)
EG-A, 12x12
(150)
EG-A, 8x8(140)
EG-A, 8x8(200)
EG-A, 8x8(200)
8ø 10ø
20x14
8ø 8ø
6ø 6ø
8ø
8ø
30x20
12x8
RG-B, 5(500), TYP-2
26x1
6
FSD-8-2FSD-8-1
FSD-8-3
FSD-8-4FSD-8-5
FSD-8-6
44x40
SP1
SA2
SA1
SP3
TX1
SP4
SP2
SA3
SA4
60x84
16x16
2
CD-A
(40)
EGA, 8x8(60)
EGA, 8x8(60)
6ø
6ø
6ø
8ø
18x12
EGA, 8x8
(60)
EGA, 8x8
(60)
114x42
36x18
114x42
40x20
20x14
CD-A(22), TYP-3
20x18 20x18
1
1 50x30
1
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
21:0
3 P
M
05.22.2015
1309100
MH108
NEW SNOHOMISHCOUNTYCOURTHOUSE
CSG
ZMS
MECHANICALFLOOR PLAN -LEVEL 8
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
NUMBERED NOTESRA DUCTED ELBOW IN L-8 CEILING TO TAP INTO AHU ROOFTOP CURB ABOVE.
FCU SERVING THE IDF ROOM WILL BE PROVIDED WITH MIXING BOXES AND DUCTED OUTSIDE AIRLOUVERS W/ 4.0SF OF NFA.
1
SHEET NOTES1. THERMOSTAT LOCATION TO BE COORDINATED W/ ARCH. ONE THERMOSTAT PER TERMINAL UNIT.2. CARBON DIOXIDE DEMAND CONTROL VENTILATION IN ALL COURTROOMS & MEETING ROOMS.3. PROVIDE FLEX DUCT CONNECTIONS TO ALL SUPPLY DIFFUSERS AT A MAXIMUM LENGTH OF 5FT. 2
HP1
HP2
SPF3
SPF4
SPF1
SPF2
HPF2
HPF1
HPF5
HPF4
HPF3
PRF5
ELEV
STAIRSHAFT
ELEV SHAFT
STAIR SHAFT
ELEV ELEV
ELEV
STAIR SHAFT
STAIRSHAFT
44x40
60x84
40x44 40x44
50x5050x50
40x44
60x84
40x44
50x22
50x22
45x18
45x16
35x25 48x18
66x36
66x36
55x100
55x10040x44
1 1.1 2 3 4 5 6 6.9 7
A
B
C
D
6.15.25.14.24.13.23.12.22.11.61.4
30x50
30x26
30x50
30x26
EF13
HP3
HP4
AHU1
AHU2
AHU3
AHU4
DOAS2
DOAS1
PHP1
PHP2
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
21:1
1 P
M
05.22.2015
1309100
MH109
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALROOF LEVEL
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
SHEET NOTES
NUMBERED NOTES
1. xxx
ACCESS PATHWAY TO ROOFTOP MECHANICAL EQUIPMENT.1
1
UP
DN
VEHICLE SPB-231
INMATEELEV.
E5
STAIRST4-B
INMATEELEV.
E8
STAIRST5-B
ELEV.E6
CORR.B-100Z
EVID. STOR.B-130
EM. POWERB-105
FM OFFICEB-160
DEPUTYSTATIONB-200B
NORMALPOWERB-110
PED ADULTS.P.
B-212
OFF.STATION
B-211
JCB-213
J.C.B-101
CORRB-110Z
MUSTER/MTGB-209A
M CELLB-222
M CELLB-223
M CELLB-221
M CELLB-220
SEC. VEST.B-209 TOILET/
SHOWERB-209B
F GROUPCELLB-206
F CELLB-207
F CELLB-208
F CELLB-210
F JUV. CELLB-205
M CELLB-202
M CELLB-203
M GROUPCELLB-204
SEC VESTB-214
SEC VESTB-219
M GROUPHOLDING
B-218
M GROUPCELLB-217
M GROUPCELLB-216
M CELLB-215
SEC VESTB-230
GUNLOCKERS
B-200
CORR.B-205Z
SERV./PRIVATE
ELEV.LOBBYB-100
LOADINGDOCK/RECEIVING/
PACKAGESCREEN
B-165
M JUV. CELLB-201
MAIL DIST.B-115
ELEV.E1
ELEV.E7
ELEV.LOBBYB-002
EQUIP ROOMB-138B
TOILETB-138A
CENTRALCONTROL
B-138
S.P.B-137
FIRECOMMAND
B-140
DOMESTICWATERENTRYROOMB-163
RECYCLINGCLOSET
B-161
MDFB-135
FIRE PUMPROOMB-139
FMB-162
OLYMPICSEC
B-120
FURN STOR.B-125B
JANITORSTOR.B-125C FIRE TANK
ROOMB-139A
MEDICALEQUIP STOR
B-001
SHOPSB-125A
STAFF TOIL.B-136
CORRB-161Z
CORRB-200Z
CORRB-137Z
N-C INT.B-220
N-C INT.B-219
STAIRB-305
VEST /LOBBYB-200A
CORR.B-215Z
VEST /LOBBYB-240
CORR.B-211Z
CORR.B-201Z
CORRB-161ZCORRB-161Z
1 1.1 2 3 4 5 6 6.9 7 8
A
B
C
D
E
F
F.5
6.15.25.14.24.13.23.12.22.11.61.4
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
6" HWS/R
8" CHWS/R
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
B
A
Key Plan
5/21
/201
5 6:
21:1
6 P
M
05.22.2015
1309100
MP100A
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALPIPING FLOORPLAN - BASEMENTLEVEL
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
SHEET NOTES
NUMBERED NOTESxxx1
MP100B
MP100A
MP100B
MP100A
1. PROVIDE THERMAL EXPANSION COMPENSATIONFOR ALL HW PIPING.
DNUP
MUSTER/MTGB-209A
SEC. VEST.B-209 TOILET/
SHOWERB-209B
F GROUPCELLB-206
M GROUPCELLB-204
LOADINGDOCK/RECEIVING/
PACKAGESCREEN
B-165
TRANSFORMERVAULTB-302
TRANSFORMERVAULTB-301
DOMESTICWATERENTRYROOMB-163
SERVICEYARDB-310
STAIRST6-B
STAIRB-305
SERVICEYARDB-310
SERVICEYARDB-310
SERVICEYARDB-310
SERVICEYARDB-310
1 1.1 2 3 4 5 6 6.9 7 8
P-B
A
P-A
6" HWS/R 8" CHWS/R 1
000 6" 1'-0" 1'-6"
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1 1/2" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
B
A
Key Plan
5/21
/201
5 6:
21:2
0 P
M
05.22.2015
1309100
MP100B
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALPIPING FLOORPLAN - BASEMENTLEVEL SERVICEYARD
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
SHEET NOTES
NUMBERED NOTESPROVIDE REFRIGERANT VENTLINES TO EXTERIOR
1
MP100B
MP100A
MP100B
MP100A
1. PROVIDE THERMAL EXPANSION COMPENSATIONFOR ALL HW PIPING.
UP
DN
COMMISSIONERCOURTROOM
1-A00
ELEV.E8
ELEV.E5
STAIRST4-1
ELEV.E6
ELEV.E1
STAIRST5-1
CELL1-A14
OFF. STAT.1-A13
SOUNDLOCK1-B05
SOUNDLOCK1-A05
ATTY. INT.1-B01
W. TOILET1-010
M. TOILET1-012
SEC. VEST.1-A10
N-C INT.1-A11
STAIRST3-1
COMMISSIONERCOURTROOM
1-B00
COMMISSIONERCOURTROOM
1-C00
ATTY. INT.1-A01
ATTY. INT.1-D01
COMMISSIONERCOURTROOM
1-D00
TECH EQUIP1-442
ELEC.1-441
PUBLICELEV.
LOBBY1-002
STAIRST2-1
SEC. VEST.1-B10
SEC. ELEV.ALCOVE
1-A17
EQUIP.STOR.1-445
A/V ROOM1-444
SHAFTS2
SHAFTS1
PUBLICLOBBY1-004
CELL1-B14
DISTRICTHEARING
ROOM1-E00
STOR.1-011
TECH EQUIP1-401
ATTY. INT.1-C01SOUND
LOCK1-C05
SOUNDLOCK1-D05
STAFFTOILET1-430
N-C INT.1-B12
SOUNDLOCK1-E05
IDF1-425
STAFFTOILET1-403
SERV./PRIVATE
ELEV.LOBBY1-440
VEST.1-441Z
CORR.1-420Z
IDF1-203
ELEC1-021
TSER1-020
ELEC.1-402
MEDIAROOM1-E01
WRKALCOVE
1-C02EQUIP.STOR.1-121
SOUNDLOCK1-443Z
A/V ROOM1-429
TECH EQUIP1-426
WAITING1-015
N-C INT.1-A12
N-C INT.1-B11
STAIR # 1ST1-1
VEST.1-008
CEREMONIALCOURTROOM/
JURYASSEMBLY
1-215
SECUREJUROR
WAITING1-223
CORR.1-202Z
CART/PODIUM
STORAGE1-201
M. TOILET1-212
JURYCHECK-IN/QUEUING
1-200
COURTADMINSTAFF1-220
W. TOILET1-210
A/V1-202
SUP. CLERK1-221
JURYLOUNGE
1-204
CORR.1-221Z
TECHNOLOGYBAR
1-210Z
WORK/FILES/
STORAGE1-222
WAITING1-005
WAITING1-006
LAWLIBRARY/STOR
1-125
WAITING1-001
WAITING1-003
PUBLICVENDING
1-001A
OFFICE1-126
ATTY ADMIN1-306
WAITING1-300
OPERATIONSMGR1-305
COPY/STOR/DENNYYOUTH1-302
OPENOFFICE1-301
CORR.1-100Z
M LOCKER /SHOWERS
1-102A
M. TOILETS1-102
F. TOILETS1-104
JC1-105
F LOCKER /SHOWERS
1-104A
INJ. ROOM1-101
LACT. ROOM1-103
STAFFBREAKRM
1-106
ELEC.1-404
SHOW/CAUSECONF ROOM
1-116
OPENOFFICE
WORK AREA1-118
STOR/WORKRM
1-117
ATTY. BARASSN.1-120
OPENOFFICE1-115
COMMOFFICE1-451
COMMOFFICE1-450
CORR.1-450Z
WRK/ FILES/STOR1-437 COMM
OFFICE1-436
COMMOFFICE1-427
COMMOFFICE1-421
DRUGCOURTCOORD.
1-515
DRUGCOURTCOORD.
1-514
DRUGCOURTCOORD.
1-513
DRUGCOURTSPVR.1-512
SPCLTYCOURT MGR
1-511
CORR.1-510ZCLOS.
1-516TOILET1-502
WAITINGROOM1-500
VEST.1-600Z
CORR.1-301Z
OPENOFFICE1-600
CORR.1-004Z
CONF/DINING1-420
CORR.1-C00Z
PUBLICCOUNTER
1-123
ELEV.E7
ELEV.E2
ELEV.E3
COMM.TOILET1-435
COMM.TOILET1-428
CORR.1-435Z
VEST1-436Z
CORR.1-404Z
TBD1-110
CORR.1-020Z
CORR.1-021Z
ATTY HOTEL1-132
CORR.1-325Z
CORR.1-501Z
VEST1-003Z
VEST1-005Z
CORR.1-002Z
SHAFTS3
TBD1-122
OBSERVATION1-502
CORR.1-325ZCORR.1-325Z
1 1.1 2 3 4 5 6 6.9 7 8
A
B
C
D
E
F
F.5
6.15.25.14.24.13.23.12.22.11.61.4
3/4" HWS/R1-1/4" HWS/R
3/4" HWS/R
1-1/4" HWS/R
1" HWS/R3/4" HWS/R
3/4" HWS/R
1" HWS/R
3/4" HWS/R3/4" HWS/R
3/4" HWS/R
FPB1-5
FPB1-4
FPB1-3
FPB1-34
FPB1-6
FPB1-11
FPB1-15
FPB1-12
FPB1-31
FPB1-33
FPB1-13
FPB1-32
FPB1-17
FPB1-19
FPB1-21
FPB1-20
FPB1-2
FPB1-1
FPB1-25
FPB1-24
FPB1-23
FPB1-22
FPB1-10
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
B
A
Key Plan
5/21
/201
5 6:
21:2
7 P
M
05.22.2015
1309100
MP101A
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALPIPING FLOORPLAN - LEVEL 1
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
SHEET NOTES
NUMBERED NOTES
1. PROVIDE THERMAL EXPANSION COMPENSATIONFOR ALL HW PIPING.
xxx1
MP101B
MP101A
MP101B
MP101A
DN
COMMOFFICE1-451
WRK/ FILES/STOR1-437 COMM
OFFICE1-427
COMMOFFICE1-421
DRUGCOURTCOORD.
1-515
DRUGCOURTCOORD.
1-514
DRUGCOURTCOORD.
1-513
DRUGCOURTSPVR.1-512
SPCLTYCOURT MGR
1-511
VEST1-436Z
GENERATOR1-701
COOLINGTOWER1-702
SECUREPARKING
1-700
CORR.1-501Z
GENERATOR1-701
SECUREPARKING
1-700
GENERATOR1-701
SECUREPARKING
1-700
GENERATOR1-701
GENERATOR1-701
1 1.1 2 3 4 5 6 6.9 7 8
P-B
A
P-A
1
CWR
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
B
A
Key Plan
5/21
/201
5 6:
21:3
3 P
M
05.22.2015
1309100
MP101B
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALPIPING FLOORPLAN - LEVEL 1PARKING
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
SHEET NOTES
NUMBERED NOTESCONDENSER WATER CONNECTION1
MP101B
MP101A
MP101B
MP101A
1. PROVIDE THERMAL EXPANSION COMPENSATIONFOR ALL HW PIPING.
UP
DN
ELEV.E5
ELEV.E8
STAIRST4-2
STAIRST5-2
ELEV.E1
W. TOILET2-010
ST. TOILET2-512
M. TOILET2-012
ELEV.E3
FINANCEMGR2-281
HD STORVAULT2-287
MICROFICHESTOR.2-248
ST. TOILET2-284
TELE ROOM2-250
SECURESTOR.2-511
S.C.A. STOR.2-506
SCOC MGR2-279
OPENOFFICE2-510
MAIL/COPY/WKRM2-280A
STOR.2-276
SUPPLY/STOR.2-621
SUPPORTWORKAREA2-510A
ELEC.2-286
ELEC.2-620
FIN. FILE RM2-282
W. TOILET2-247A
HD STORVAULT2-246
FIN. STOR/STOR/VAULT2-285
OPENSHELVING
AREA -VAULT2-236
JRARECORDS
MGR2-240
STAIRST3-2
SCA MGR2-515
SERV./PRIVATE
ELEV.LOBBY2-513
ELEV.E6
SHAFTS1
SHAFTS2
PUBLICELEV.
LOBBY2-002
CUST. SERV.AREA2-270
SUP. CLERK2-260
IDF2-277
PROB OFCR2-602
PROB OFCR2-603
WORK/COPY2-610D
SUPERVISOR2-610B
RECEPTION /WAITING
2-600
PROBFILING/STOR
2-610A
STOR.2-615
FILES/ FILEROOM2-616
CORR2-601Z
CORR2-004Z
STAIRST2-2
STOR.2-011
SEALED ANDHD STORRECORDS
VAULT2-237
SECURITYSCREENING
2-105
GUNREMOVAL
1-109
RECD'SSPECIALIST
2-604
S.C.A. STOR.2-505
MARSHALSTATION
1-110
SECURITYQUEUING
2-102
STAIRST3-2STAIRST3-2
OPEN OFC2-215
ELEC2-230
SECURITYSCREENING
2-106
SECURITYSCREENING
2-107
ENTRY VEST.2-100
SERV UNIT2-283
SERVUNIT/COPY
2-227
CLRK OFCOURTS
2-228
EVIDENCESTOR2-231
CHIEFDEPUTY
CLRK2-226
JOA MGR2-222
COPY/PRINT/WORK
AREA2-206
CS MGMTJUV MGR
2-202
IDF2-201
STAFFMEETING
ROOM2-013
STAFFMEETING
ROOM2-014
STORAGEROOM2-209
FILES/STOR.2-217
ELEV.E2
ELEV.E7
OPEN OFC2-205
OPEN OFC2-200
OPEN OFC2-225
OPEN OFC2-610
DIST. CLRK.2-630
SUPR. CRT.ADMIN.2-501
SUPPLY/FILE STOR
2-221SERV UNIT/LOCKERS
2-208
CORR.2-207Z
WAITING2-006
WAITING2-005
OPEN OFC2-249
MENTALHEALTHCOORD
2-601
EXIT VEST.2-101
WAITING2-220
OPEN OFC2-235
OPEN OFC2-280
CORR2-279Z
CORR2-250Z
ST.TOILET2-216 CORR.
2-015Z
VEST.2-008
SHAFTS3
SUP. CLERK2-260
CORR2-274Z
CART STOR2-207
STAIRST1-2
LOBBY2-115
CORR2-003Z
CORR2-002Z
CORR2-001ZCORR
2-001A
CORR.2-222Z
CORR.2-205Z
CORR.2-510Z
CORR.2-617Z
1 1.1 2 3 4 5 6 6.9 7 8
A
B
C
D
E
F
F.5
6.15.25.14.24.13.23.12.22.11.61.4
3/4" HWS/R 1-1/4" HWS/R
1-1/2" HWS/R
1" HWS/R
1-1/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R1" HWS/R
1" HWS/R
3/4" HWS/R
3/4" HWS/R
RFS2-1
RFM2-1
RFM2-1
RFP2-1
FPB2-6
FPB2-7
FPB2-12
FPB2-1A
FPB2-8
FPB2-13
FPB2-10
FPB2-14
FPB2-11
FPB2-3
FPB2-17
FPB2-4
FPB2-16
FPB2-5
FPB2-15
FPB2-9
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
21:3
9 P
M
05.22.2015
1309100
MP102
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALPIPING FLOORPLAN - LEVEL 2
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
SHEET NOTES
NUMBERED NOTESxxx1
1. PROVIDE THERMAL EXPANSION COMPENSATIONFOR ALL HW PIPING.
DN
ELEV.E3
ELEV.E1
STAIRST2-3
STOR.3-011
CORR.3-004Z
ATTY. INT.3-D02
ATTY. INT.3-D04
N-C INT.3-D11
N-C INT.3-C11
STNDDISTRICT
COURTROOM3-B00
TECH EQUIP3-411 EVID STOR
3-412
A/V ROOM3-413
STAFFTOILET3-414
ASST.DIRECTOR
3-443STORAGE
3-444
OPENOFFICE3-440
DIRECTOR3-442
IDF3-434
STOR3-433
STAFFTOILET3-404 EQUIP STOR
3-405
STOR3-408
JUDICIALOFFICE3-452
ROBINGROOM3-471
FILEPROCESS
3-470
TOILET3-471A
TOILET3-463
SOUNDLOCK3-460TOILET
3-461
ELEC.3-457
FURN. STOR.3-456
FILES3-453
OPENOFFICE3-450
WRK/ FILE/STOR/ SERV
UNIT3-451
LARGE CELL3-D14
SHAFTS2
ELEV.E8
INMATEDOCK3-D15
SEC. VEST.3-D10
N-C INT.3-D12
OFF. STAT.3-C13
N-C INT.3-C12
SEC VEST3-C10
SEC. ELEV.ALCOVE
3-C17
CRIMINALHEARING
ROOM3-D00
SEC. VEST.3-A10
N-C INT.3-A11
N-C INT.3-B11
SEC. VEST.3-B10
ELEV.E5
SINGLECELL3-A14
SINGLECELL3-B14
EVID STOR3-407
TECH EQUIP3-409
SEC. ELEV.ALCOVE
3-A17
OFF. STAT.3-A13
SHAFTS1
STAIRST4-3
SERV./PRIVATE
ELEV.LOBBY3-415
CONFERENCEROOM3-441
TOILET3-432A
JUDICIALOFFICE3-432
OPENOFFICE3-430
ELEV.E6
JUDICIALOFFICE3-431TOILET
3-431A
ELEC.3-424TOILET
3-421
SOUNDLOCK3-420
TOILET3-423
JURY DELIB.3-422
A/V ROOM3-401 EVID STOR
3-403
SOUNDLOCK3-401Z
N-C INT.3-A12
N-C INT.3-B12
M. TOILET3-012
W. TOILET3-010
STAIRST3-3
TOILET3-452A
SINGLECELL3-C14
SINGLECELL3-C15
STAIRST5-3
VEST.3-476Z
ELEC.3-454
PUBLICELEV.
LOBBY3-002
CORR.3-411Z
ATTY. INT.3-B01
VICT/ WITWAITING
3-C01
SOUNDLOCK3-B05
SOUNDLOCK3-A05
PRESIDINGJUDGE'S
COURTROOM3-C00
SOUNDLOCK3-C05
ATTY. INT.3-C02
ATTY. INT.3-A01 ATTY HOTEL
3-B02
SOUNDLOCK3-D05ATTY. INT.
3-D01
STNDDISTRICT
COURTROOM3-A00
WAITINGAREA3-004
WAITINGAREA3-003
WAITINGAREA3-001
ATTY. INT.3-D03
STAIRST3-3
MAIN FILE3-119
INTERVIEW3-102
FINGERPRINT3-101
RECEPT/WAIT3-100
EMPLOYEEBADGING
3-104
CIVIL FILE3-105
IDF3-108
CIVILSUPVSR
3-112
SUP/STOR3-111
REC SUPVSR3-115
RECORDSBULLPEN
3-114
STORAGE/SUPPLIES/LET
MAILBOXES3-120
F. MARSHALCHANGE/WEAPONLOCKER
3-124
MARSHALOFC3-123
MARSHALOFC3-122
DATA ENTRY3-117
M. MARSHALCHANGE/WEAPONLOCKER
3-121
CORR3-121Z
ELEC3-125
OPENOFFICE3-103
WAITINGAREA3-005
WAITINGAREA3-006
STAFF SRVCMANAGER
3-109
VEST.3-008
OPENOFFICE3-102A
OPENOFFICE3-107
OPENOFFICE3-113
OPENOFFICE3-116
CORR.3-108Z CORR.
3-111ZCORR.3-114Z
CORR.3-130Z
LOCKERS /SERVICE
UNIT3-118
CORR.3-D01Z
CORR.3-C00Z
VEST.3-412Z
CORR3-407Z
ELEV.E7
ELEV.E2
JURY DELIB.3-462
WRK/ FILE/STOR3-402
SOUNDLOCK3-460Z
VEST.3-475Z
EVID STOR3-455
SHAFTS3
CORR.3-402Z
1 1.1 2 3 4 5 6 6.9 7 8
A
B
C
D
E
F
F.5
6.15.25.14.24.13.23.12.22.11.61.4
3/4" HWS/R
3/4" HWS/R
1-1/2" HWS/R
1-1/2" HWS/R
1-1/4" HWS/R
1" HWS/R
3/4" HWS/R
3/4" HWS/R
1" HWS/R 1" HWS/R3/4" HWS/R
3/4" HWS/R
1" HWS/R
3/4" HWS/R
FPB3-14
FPB3-6
FPB3-23
FPB3-7
FPB3-24
FPB3-8
FPB3-25
FPB3-9
FPB3-26
FPB3-27
FPB3-10
FPB3-11
FPB3-28
FPB3-13
FPB3-16
FPB3-17
FPB3-18
FPB3-12
FPB2-1C
FPB2-1B
FPB2-1
FPB3-15
FPB3-4
FPB3-3
FPB3-2
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
21:4
7 P
M
05.22.2015
1309100
MP103
NEW SNOHOMISHCOUNTYCOURTHOUSE
CSG
ZMS
MECHANICALPIPING FLOORPLAN - LEVEL 3
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
SHEET NOTES
NUMBERED NOTES
1. PROVIDE THERMAL EXPANSION COMPENSATIONFOR ALL HW PIPING.
ELEV.E5
ELEV.E8
STAIRST4-4
STAIRST5-4
ELEV.E3
STAIRST2-4
SHAFTE8
SHAFTS1
S.CELL4-B14
S. CELL4-A14
STND TRIALCOURTROOM
4-A00STND TRIAL
COURTROOM4-B00
STND TRIALCOURTROOM
4-C00
ELEV.E1
CORR.4-407Z
JURY DELIB.4-462
W. TOILET4-010
SEC VEST4-A10
S. CELL4-C14
S. CELL4-D14
JUDICIALOFFICE4-453
SOUNDLOCK4-411Z
JUDICIALOFFICE4-452
WRK/ FILE/STOR/ SERV
UNIT4-451 TOILET
4-463
FURN. STOR.4-457
JURY DELIB.4-422
SOUNDLOCK4-401Z
JUDICIALOFFICE4-431
JUDICIALOFFICE4-432
EVID STOR4-408EVID STOR
4-405A/V ROOM
4-409
SEC VEST4-C10
N-C INT.4-D11
N-C INT.4-C11
M. TOILET4-012
N-C INT.4-A11
OPENOFFICE4-450
OPENOFFICE4-430
TECH EQUIP4-407
TECH EQUIP4-406
ELEC.4-458
N-C INT.4-B11
SEC VEST4-B10
TOILET4-423
TOILET4-421
SOUNDLOCK4-420
EVID STOR4-402
ELEC.4-424
WRK/ FILE/STOR/ SERV
UNIT4-433
A/V ROOM4-401
SERV./PRIVATE
ELEV.LOBBY4-411
PUBLICELEV.
LOBBY4-002
CRT REP4-404
SEC. ELEV.ALCOVE
4-A17
OFF. STAT.4-A13 OFF. STAT.
4-C13
SEC. ELEV.ALCOVE
4-C17
TOILET4-461
SOUNDLOCK4-460
N-C INT.4-D12
N-C INT.4-A12
WAITING4-001
WAITING4-005
EVID STOR4-456
N-C INT.4-B12
N-C INT.4-C12
ATTY. INT.4-B01
SOUNDLOCK4-B05
SOUNDLOCK4-A05
SOUNDLOCK4-C05
ATTY. INT.4-C02
SOUNDLOCK4-D05
ATTY. INT.4-D01
ATTY. INT.4-A01
STAFFTOILET4-403
TOILET4-441
JURY DELIB.4-442
TOILET4-432A TOILET
4-452A
STOR4-433A
TOILET4-443
IDF4-434
SOUNDLOCK4-440
STAFFTOILET4-410
TOILET4-431A
TOILET4-453A
FILES4-454
ELEC.4-455
STOR.4-011
VICT/ WITWAITING
4-C01ATTY HOTEL4-B02
STAIRST3-4
CORR.4-004Z
SEC VEST4-D10
WAITING4-006
WAITING4-004
WAITING4-003
VEST4-008
VEST4-408Z
CORR.4-C00Z
VEST4-405Z
CORR4-402Z
STND TRIALCOURTROOM
4-D00
ELEV.E2
ELEV.E6
ELEV.E7
SHAFTS3
STOR4-451A
1 1.1 2 3 4 5 6 6.9 7 8
A
B
C
D
E
F
F.5
6.15.25.14.24.13.23.12.22.11.61.4
3/4" HWS/R
3/4" HWS/R1" HWS/R1" HWS/R
1-1/4" HWS/R
1-1/4" HWS/R3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R3/4" HWS/R
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
21:5
4 P
M
05.22.2015
1309100
MP104
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALPIPING FLOORPLAN - LEVEL 4
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
SHEET NOTES
NUMBERED NOTESxxx1
1. PROVIDE THERMAL EXPANSION COMPENSATIONFOR ALL HW PIPING.
ELEV.E5
STAIRST4-5
ELEV.E7
STAIRST5-5
STAIRST2-5
STAIRST3-5
SHAFTS2
SHAFTS1 S.CELL
5-B14S. CELL
5-A14
STND TRIALCOURTROOM
5-A00
STND TRIALCOURTROOM
5-B00
STND TRIALCOURTROOM
5-C00
ELEV.E1
JURY DELIB.5-462
W. TOILET5-010
SEC VEST5-A10
ELEV.E3
S. CELL5-C14
S. CELL5-D14
SEC VEST5-D10
JUDICIALOFFICE5-453
SOUNDLOCK5-415Z
JUDICIALOFFICE5-452
WRK/ FILE/STOR/ SERV
UNIT5-451 TOILET
5-463
FURN. STOR.5-457
JURY DELIB.5-422
SOUNDLOCK5-401Z
JUDICIALOFFICE5-431
JUDICIALOFFICE5-432
EVID STOR5-408EVID STOR
5-405
A/V ROOM5-409
SEC VEST5-C10
N-C INT.5-D11
N-C INT.5-C11
M. TOILET5-012
N-C INT.5-A11
OPENOFFICE5-450
OPENOFFICE5-430
TECH EQUIP5-407
TECH EQUIP5-406
ELEC.5-458
N-C INT.5-B11
SEC VEST5-B10
TOILET5-423
TOILET5-421
SOUNDLOCK5-420
EVID STOR5-402
ELEC.5-424
WRK/ FILE/STOR/ SERV
UNIT5-433
A/V ROOM5-401
SERV./PRIVATE
ELEV.LOBBY5-411
PUBLICELEV.
LOBBY5-002
CRT REP5-404
SEC. ELEV.ALCOVE
5-A17
OFF. STAT.5-A13
OFF. STAT.5-C13
SEC. ELEV.ALCOVE
5-C17
TOILET5-461
SOUNDLOCK5-460
N-C INT.5-D12
N-C INT.5-A12
N-C INT.5-B12
N-C INT.5-C12
ATTY. INT.5-B01
SOUNDLOCK5-B05
SOUNDLOCK5-A05
SOUNDLOCK5-C05
ATTY. INT.5-C02
SOUNDLOCK5-D05
ATTY. INT.5-D01
ATTY. INT.5-A01
STAFFTOILET5-403
TOILET5-441
JURY DELIB.5-442
TOILET5-432A
TOILET5-452A
STOR5-433A
TOILET5-443
IDF5-434
SOUNDLOCK5-440
STAFFTOILET5-410
TOILET5-431A
FILES5-454
ELEC.5-455
STOR.5-011
VICT/ WITWAITING
5-C01ATTY HOTEL
5-B02
CORR.5-004Z
ELEV.E8
WAITING5-006
WAITING5-005
WAITING5-004
WAITING5-003
WAITING5-001
VEST5-008
SOUNDLOCK5-402Z
VEST5-408Z
CORR.5-C00Z
VEST5-405Z
TOILET5-453A
EVID STOR5-456
LG TRIALCOURTROOM
5-D00
ELEV.E2
ELEV.E6
CORR.5-407Z
SHAFTS3
STOR5-451A
1 1.1 2 3 4 5 6 6.9 7
A
B
C
D
6.15.25.14.24.13.23.12.22.11.61.4
3/4" HWS/R
3/4" HWS/R
1-1/4" HWS/R
1-1/4" HWS/R 1" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R3/4" HWS/R
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
22:0
2 P
M
05.22.2015
1309100
MP105
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALPIPING FLOORPLAN - LEVEL 5
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
SHEET NOTES
NUMBERED NOTESxxx1
S.CELL6-B14
S. CELL6-A14
LG TRIALCOURTROOM
6-D00
STND TRIALCOURTROOM
6-A00
STND TRIALCOURTROOM
6-B00
STND TRIALCOURTROOM
6-C00
STAIRST4-6
ELEV.E5
ELEV.E2
CORR.6-407Z
JURY DELIB.6-462
W. TOILET6-010
SEC VEST6-A10
ELEV.E3
ELEV.E8
STAIRST5-6
S. CELL6-C14
S. CELL6-D14
SEC VEST6-D10
JUDICIALOFFICE6-453
SOUNDLOCK6-415Z
JUDICIALOFFICE6-452
WRK/ FILE/STOR/ SERV
UNIT6-451
TOILET6-463
FURN. STOR.6-457
JURY DELIB.6-422
SOUNDLOCK6-401Z
JUDICIALOFFICE6-431
JUDICIALOFFICE6-432
EVID STOR6-405
A/V ROOM6-409
SEC VEST6-C10
N-C INT.6-D11
N-C INT.6-C11
M. TOILET6-012
N-C INT.6-A11
OPENOFFICE6-450
OPENOFFICE6-430
TECH EQUIP6-407
TECH EQUIP6-406
ELEC.6-458
ELEV.E6
N-C INT.6-B11
SEC VEST6-B10
TOILET6-423
TOILET6-421
SOUNDLOCK6-420
EVID STOR6-402
ELEC.6-424
WRK/ FILE/STOR/ SERV
UNIT6-433
A/V ROOM6-401
SERV./PRIVATE
ELEV.LOBBY6-411
PUBLICELEV.
LOBBY6-002
CRT REP6-404
SEC. ELEV.ALCOVE
6-A17
OFF. STAT.6-A13
OFF. STAT.6-C13
SEC. ELEV.ALCOVE
6-C17
TOILET6-461
SOUNDLOCK6-460
SHAFTS2
SHAFTS1
N-C INT.6-D12
N-C INT.6-A12
CORR.6-004Z
WAITING6-006
STAIRST2-6
STAIRST3-6
N-C INT.6-B12
N-C INT.6-C12
ATTY. INT.6-B01
SOUNDLOCK6-B05
SOUNDLOCK6-A05
SOUNDLOCK6-C05
ATTY. INT.6-C02
SOUNDLOCK6-D05
ATTY. INT.6-D01
ATTY. INT.6-A01
STAFFTOILET6-403
TOILET6-441
JURY DELIB.6-442
TOILET6-432A
TOILET6-452A
STOR6-433A
TOILET6-443
IDF6-434
SOUNDLOCK6-440
STAFFTOILET6-410
TOILET6-431A
FILES/ STOR6-454
ELEC.6-455
STOR.6-011
VICT/ WITWAITING
6-C01
ATTY HOTEL6-B02
CORR6-402Z
WAITING6-001
WAITING6-004 WAITING
6-005
WAITING6-003
VEST.6-008
EVID STOR6-408
VEST6-408Z
VEST6-405Z
CORR.6-C00Z
EVID STOR6-456
SHAFTS3
ELEV.E7
ELEV.E1
TOILET6-453A
STOR6-451A
1 1.1 2 3 4 5 6 6.9 7
A
B
C
D
6.15.25.14.24.13.23.12.22.11.61.4
3/4" HWS/R
1" HWS/R
1" HWS/R1-1/2" HWS/R
3/4" HWS/R
1" HWS/R1-1/4" HWS/R3/4" HWS/R
1-1/2" HWS/R
3/4" HWS/R3/4" HWS/R
1" HWS/R
1" HWS/R 3/4" HWS/R3/4" HWS/R
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
22:0
9 P
M
05.22.2015
1309100
MP106
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALPIPING FLOORPLAN - LEVEL 6
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
SHEET NOTES
NUMBERED NOTESxxx1
1. PROVIDE THERMAL EXPANSION COMPENSATIONFOR ALL HW PIPING.
UP
SHAFTS2
TRIALNVL/DRG
DEPUTY PA7-256
TRIALNVL/DRGLEAD PA
7-252
TRIALNVL/DRG
DEPUTY PA7-262
APPEALSDEPUTY PA
7-250
TRIALNVL/DRG
DEPUTY PA7-258
TRIALNVL/DRG
DEPUTY PA7-260
TRIALNVL/DRG
DEPUTY PA7-264
TRIALNVL/DRG
DEPUTY PA7-263
TRIALNVL/DRG
DEPUTY PA7-261
APPEALSDEPUTY PA
7-251ADMINSTAFF7-233
INTERN DP7-138
FELONY FILE7-222
OPENOFFICE7-249
TRIALNVL/DRG
DEPUTY PA7-265
CONFERENCEROOM7-202
CONFERENCEROOM7-203
CONFERENCEROOM7-204
NVL/DRGDEPUTY PA
7-135
APPEALSDEPUTY PA
7-137
NVL/DRGDEPUTY PA
7-142
NVL/DRGLEAD DEP
PA7-143
NVL/DRGDEPUTY PA
7-145
NVL/DRGDEPUTY PA
7-146
NVL/DRGDEPUTY PA
7-147
NVL/DRGDEPUTY PA
7-139
DISTRICTADVOCATE /
PL7-149
DISTRICTDEPUTY PA
7-210
DISTRICTDEPUTY PA
7-209
DISTRICTDEPUTY PA
7-208
DISTRICTDEPUTY PA
7-207
DISTRICTDEPUTY PA
7-206
DISTRICTDEPUTY PA
7-220
DISTRICTDEPUTY PA
7-221
DISTRICTDEPUTY PA
7-223
DISTRICTDEPUTY PA
7-225
DISTRICTDEPUTY PA
7-227
INTERN DP7-255
LEADDISTRICT
DEPUTY PA7-212
ELEC.7-237
SHAFTS1
ELEC.7-120
STAIRST4-7
COPY/FILES/WORK7-236
OPS CHIEF7-243
CHIEFDEPUTY PA
7-128
DISTRICTADVOCATE /
PL7-211
APPEALSDEPUTY PA
7-235
COPY/FILES/WORK7-108
PUBLICWAITING
7-003
INTERN DP7-125
STAIRST2-7
VIOLENT/DVDEPUTY PA
7-118
VIOLENT/DVLEAD
DEPUTY PA7-117
VIOLENTLEAD
DEPUTY PA7-115
VIOLENT/DVDEPUTY PA
7-114
VIOLENT/DVDEPUTY PA
7-110
VIOLENTDEPUTY PA
7-106
VIOLENTDEPUTY PA
7-105
VIOLENTDEPUTY PA
7-103
VIOLENTDEPUTY PA
7-101
VIOLENTDEPUTY PA
7-102
VIOLENTCRIMINAL
MGR7-104
VIOLENT/DVDEPUTY PA
7-112
VIOLENT/DVADV / PL
7-129
VIOLENT/ADVOCATEPARALEGAL
7-141
RECEPTIONWORK AREA
7-201
PUBLICELEV.
LOBBY7-002
COPY/FILEAREA7-116
PROSECUTOR7-245
CRIMINALMGR7-113
CRIMINALADVOCATE /
PL7-234
W. TOILET7-010
SERVICEDOG STOR.
7-127
CRIMINALADVOCATE /
PL7-232
APPEALSCHIEF
DEPUTY PA7-254
STOR.7-242
DUI/MHCOURT DPA
7-230
DUI/MHCOURT DPA
7-231
CORR./SERV. UNIT
7-222Z
CRIMINALMGR7-205
OPENOFFICE7-126
STAIRST3-7
M. TOILET7-012
TRIALNVL/DRG
DEPUTY PA7-253
DISTRICTDEPUTY PA
7-148
ELEV.E6
SERV./PRIVATE
ELEV.LOBBY7-121
STOR.7-241
ELEC.7-240
CORR.7-120Z
ELEV.E1
ELEV.E3
CORR.7-001Z
CORR.7-004Z
VIOLENT/DVADV / PL
7-111
VIOLENT/ADVOCATEPARALEGAL
7-140
DISTRICTFILES7-151A
OPENOFFICE7-150
OFFSITEATTORNEY
PROSECUTING/ SERV. UNIT
7-013
FELONY FILE7-224
IDF7-130
STOR.7-011
CORR.7-008
408 SFOPEN OFFICE
226 SF9.141,9.122,9.124
OPENOFFICE7-151
CORR.7-101Z
OPENOFFICE7-107
CORR./SERV. UNIT
7-140Z
CORR.7-130Z
CORR.7-234Z
CORR.7-257Z
OPENOFFICE7-257
ELEV.E2
ELEV.E7
SHAFTS3
1 1.1 2 3 4 5 6 6.9 7
A
B
C
D
6.15.25.14.24.13.23.12.22.11.61.4
3/4" HWS/R
3/4" HWS/R
1-1/4" HWS/R
1-1/4" HWS/R
1" HWS/R
1" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
22:1
5 P
M
05.22.2015
1309100
MP107
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALPIPING FLOORPLAN - LEVEL 7
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
SHEET NOTES
NUMBERED NOTESxxx1
1. PROVIDE THERMAL EXPANSION COMPENSATIONFOR ALL HW PIPING.
UP
ELEV.E1
W. TOILET8-010
M. TOILET8-012
SHAFTS2
STAIRST2-8
ELEC.8-255
STAIRST3-8
VEST8-008
IDF8-228
SHAFTS1
ELEV.E3
STAFFTOILET8-132
STAFFTOILET8-131
SUPPLIES8-203
FISCALFILE/STOR
8-207
STORAGE8-203A
S-OPS LT8-205
RECEPTION/ADMIN8-202
FINANCEMGR8-208
VOLDIRECTOR
8-217
FINANCEMGR8-209
PUBLICAFFAIRS
8-243
LET LEAD8-204
RSO FILES8-269
SECURE RPTFORMSSTOR8-253
INVEST.SUPPLY/STORAGE
ROOM8-270
MCURECORDS
8-262
EVIDENCEPROCESS
8-261
CONFERENCEROOM8-252S-OPS
CAPTAIN8-230
CAPT OFINVEST8-254
SHERIFF8-233
UNDERSHERIFF8-236
BUREAUCHIEF
PUBLICDISCL8-234
ODDCAPTAIN
8-229
BUREAUCHIEF ODD
DEP8-235
MCUBULLPEN
8-260
INVESTLIEUTENANT
8-280
OPA SGT 18-282
OPA SGT 28-284GEN INVST
SGT8-285
MCU SGT8-283
VOL WORK8-281INT RM
8-266INT RM8-267
POLYGRAPHINT/TEST
8-268
SUPPLY/STOR.ROOM8-244
FEMALELOCKERS
8-287
MALELOCKERS
8-286
ODD SGT8-214
ODD SGT8-215
ODD LT LETLEAD8-216
NON-SECSTOR8-225
KINARDCONFERENCE
ROOM8-226
CORR.8-225Z
CONF8-130
SM JUDICIALMTG8-125
OPENOFFICE8-231
CLOS.8-263
PUBLICELEV.
LOBBY8-002
RECEPTION/WAIT8-201
ELEV.E8
STORAGE/WORK RM
8-251
DRY CLEAN8-011
SHAFTS1
CT ADMNCONF8-111
FILES8-106
RECEPTIONWAITING
8-101
SUPPORT8-104
WORK/ MAIL8-105
LARGEJUDICIAL
CONF8-102
STOR8-102A
ASST.COURTADMIN.8-115
COURTADMINISTRATOR
8-114
CASE FLOWMANAGER
8-113
BUS.ANALYST
8-112
STAFF SRVCUNIT8-103
STOR.8-117
STOR.8-227
OPEN WORKAREA8-110
CORR8-130Z
CORR8-110Z
CORR8-112Z
CORR8-117Z
SERV./PRIVATE
ELEV.LOBBY8-121
ELEC.8-118
OPENOFFICE8-219
CORR8-242Z
OPENOFFICE8-242
OPENOFFICE8-206
CORR8-210Z
CORR8-203Z
CORR8-215Z
CORR8-230Z
CORR8-280Z
CORR8-285Z
SHAFTS3
CORR8-002Z
CORR8-001Z
TOILET8-150
FISCALFILE/STOR
8-210
CORR8-235Z
CLOS.8-130A
BUREAUCHIEF TECH
SUPPORT8-232
STAIRST4-8
ELEV.E6
ELEV.E2
ELEV.E7
CORR8-101Z
COLLABORATIONAREA8-288
1 1.1 2 3 4 5 6 6.9 7
A
B
C
D
6.15.25.14.24.13.23.12.22.11.61.4
1" HWS/R
1" HWS/R
6" HWS/R
1" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
1" HWS/R 4" HWS/R
4" HWS/R UPTO AHU R-2
6" CHWS/RUP TO AHU R-2
4" HWS/R UPTO AHU R-1
6" CHWS/RUP TO AHU R-1
2-1/2" HWS/R UPTO AHU R-3
4" CHWS/RUP TO AHU R-3
2-1/2" HWS/R UPTO AHU R-4
4" CHWS/RUP TO AHU R-4
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
22:2
3 P
M
05.22.2015
1309100
MP108
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALPIPING FLOORPLAN - LEVEL 8
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
SHEET NOTES
NUMBERED NOTESNOT USED1
1. PROVIDE THERMAL EXPANSION COMPENSATIONFOR ALL HW PIPING.
1 1.1 2 3 4 5 6 6.9 7
A
B
C
D
6.15.25.14.24.13.23.12.22.11.61.4
000 4' 8' 16'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/8" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
22:2
8 P
M
05.22.2015
1309100
MP109
NEW SNOHOMISHCOUNTYCOURTHOUSE
MWL
CSG
MECHANICALPIPING ROOF PLAN
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
LEVEL 0433' - 4"
LEVEL 0550' - 0"
4
LEVEL 0433' - 4"
LEVEL 0550' - 0"
4
LEVEL 0433' - 4"
LEVEL 0550' - 0"
4
TOS LEVEL 0549' - 5 1/2"
4
26x16 26x16
HWS
HWR
RG-B, 4'
(450), TYP-2
000 2' 4' 8'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/4" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
18:5
9 P
M
05.22.2015
1309100
M-301
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALSECTIONS
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
1/4" = 1'-0"M-3011 CENTRAL COORDIDOR HVAC SECTION
TRANSFORMERVAULTB-302
TRANSFORMERVAULTB-301
CWP1
CWP2
CWP3
CH1
CH2
CHWP3
CHWP2
CHWP1
HWP3
HWP2
HWP1
B1
B2
CT1
2 3 4
P-B
A
1 20x20
20x201
2
8ø
8ø8ø8ø
3
000 2' 4' 8'
SCALE:
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
1/4" = 1'-0"
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:0
3 P
M
05.22.2015
1309100
M-401
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALENLARGED PLANS
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
1/4" = 1'-0"M-4011 MECHANICAL ROOM ENLARGED PLAN - HVAC
NUMBERED NOTESTRANSFORMER EXHAUST CONCRETE DUCT.PROVIDE WITH 3 HR FIRE RATING.
1
COMBUSTION AIR AND EXHAUST FLUE RISER LOCATINO TO BE COORDINATED.2
CHILLER ROOM EXHAUST. PROVIDE REFRIGERANT SENSORS, EXHAUST FAN, AND VENT INACCORDANCE WITH CODE.
3
COIL DRAIN WITH HOSECONNECTION & CAP
PETES PLUG
BUTTERFLY VALVE
2-WAY MODULATING VALVE
BALANCING VALVE(VENTURI)
SUPPLY
RETURN
MANUAL AIRVENT
UNIONWATER
COIL
1/2" DRAIN LINE
NOTE:WATER PIPING SHALL BE SCHEDULE 40, ASTM-120 BLACK STEEL. CONDENSATE DRAIN PIPING SHALL BESCHEDULE 40 GALVANIZED STEEL PIPE OR TYPE L HARD DRAWN COPPER TUBING. INSULATE ALLPIPING, VALVES, FITTINGS & ACCESSORIES WITH FIBERGLASS INSULATION (1" CHW, 1/2" DRAIN) WITHFACTORY APPLIED WHITE VAPOR BARIER, FACTORY APPLIED PRESSURE SENSITIVE TAPE CLOSURESYSTEM AND MATCHING BUTT STRIPS. INSULATION SHALL BE MANVILLE MICRO-LOK APT, OWENS-CORNING ASJ/SSL OR CERTAINTEED SNAP-ON ASJ/SSL. INSTALL TEST PLUGS IN EASILY ACCESSIBLELOCATIONS WITH MINIMUM OF 12" CLEARANCE IN FRONT.
32" MINIMUM
NOTES:1. WHERE TIGHT CONDITION OBSTRUCTS INSTALLATION SHOWN, USE 24x24 RETURN AIR INLET GRILLE WITH
14" DIAMETER COLLAR AND 14" DIAMETER ACOUSTICAL FLEXIBLE DUCT APPROXIMATELY 4'-0" LONG.SUPPORT FLEXIBLE DUCT RIGIDLY IN PLACE.
2. PROVIDE WHERE SHOWN ON DRAWINGS.
24x24 RETURNAIR INLET GRILLE(REFER TOSPECIFICATION)
CEILING
1" ACOUSTICALLINING WITH SHEETMETAL NOSINGUPSTREAM& DOWNSTREAM
1 1/4" GALVANIZEDSHEET METAL STRAPATTACHED TO STRUCTURE
1/2" x 1/2" WIREMESHSCREENFASTENEDTODUCTWORK
FASTEN DUCTTO COLLARWITH #10SCREWS
14x14I.D. DUCT
ENGINEER NOTE1. SHOW ACOUSTIC ELBOWS ON FLOOR PLANS USING
CAD STANDARD BLOCK ON MENU.2. CONFIRM SPEC SECTION 15800 HAS ACOUSTIC
FLEXABLE DUCT SPECIFIED.
14x14 DUCTCOLLAR
BOILER OUTLET1" PIPE TOFLOOR DRAIN
VALVEBODYDRAIN
RELIEF VALVE
STRUCTURE
1"
PIPE SUPPORTCLAMP
STRUCTURE
DISCHARGEPIPE FULLCONNECTIONSIZE OF BOILER
3/4" DRAIN
UNION(TYP.)
3/4"
DISCHARGE PIPEUP THRU ROOF
"W"
AIR FLOW
MAIN BRANCHDUCT
L= 1/4 "W, 4"MIN.
SUB BRANCH DUCT
45°
"L"
ALL BRANCH CONNECTIONS SHALL BE PROVIDED WITHOPPOSED BLADE DAMPER WITH LOCKING QUANDRANT ORYOUNG'S REGULATOR IN CEILING IF DAMPER IN NOTACCESSIBLE. SINGLE BLADE DAMPER TO BE USED OFBRANCH DEPTH IS 6" OR LESS INSIDE. MULTIBLADEDAMPER IF LARGER. FOR DUCT UP TO 18" WIDE, USE 22GAUGE BLADES. FOR DUCTS UP TO 19" TO 48" WIDE USE16 GAUGE BLADES.
NOTES:
1. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND COORDINATING LOCATIONSOF STRUCTURAL SUPPORTS FOR COOLING TOWER AND ASSOCIATED PIPING WITH ARCHITECT.COORDINATE CONDENSER WATER PIPING NPSH REQUIRED WITH HEIGHT OF COOLING TOWER SUMPOUTLET.
2. COOLING TOWER SUPPLY/RETURN CONDENSER WATER PIPING HUNG FROM COOLING TOWERSTRUCTURAL STEEL SUPPORT.
AIR INTAKE
AIR DISCHARGE
COOLING TOWER STEELSUPPORT FRAME
ROOFINGSYSTEM
AIR INTAKE
VIBRATION ISOLATION
EXISTINGWALL
COOLING TOWER
DRILL 3/4" DIA. HOLE THRUSUPPORT BEAM AND BOLTTOWER DOWN
BOLTS THRU FRAME, ISOLATION MATERIALAND BEAM FLANGE SHALL REMAIN LOOSESO AS NOT TO PRE-DEPRESS ISOLATIONMATERIAL. LOCK NUTS SHALL BE POSITIONEDAND SET TO ALLOW 1/8" CLEARANCE BELOWBEAM FLANGE
ELASTORIB OR EQUALISOLATION MATERIALSIZED PER MATERIALMFR. RECOMMENDATIONS.
COOLING TOWERSUPPORT ANDMOUNTINGFRAME
5/8" BOLTS,WASHERS ANDDOUBLE NUTS (8PER EACH SIDE OFCOOLING TOWER)
SUPPORT BEAM. REFER TOSTRUCTURAL DRAWINGS
SUPPLY DIFFUSER
CEILING TEE
CEILING TILE
STAINLESS STEEL DRAWBAND 1/2" MIN. WIDTH
DRAW BAND WITH CABLESUPPORT ATTACHED TOSLAB ABOVE WHEN FLEX DUCTIS 5' OR LONGER
FLEXIBLE DUCT. SAME ASDIFFUSER NECK SIZE MIN.LENGTH 3' MAX. LENGTH 5'
BALANCINGDAMPER. LOCATE ATBRANCH TAKE-OFF.
STAINLESS STEELDRAW BAND 1/2"MIN. WIDTH
MIN. RADIUS (R) 1.5TIMES NECK DIA.
90°MIN.
R
AIR FLOW
CEILING MOUNTEDRETURN AIR GRILLEWHERE SHOWN ONDRAWINGS. SEESCHEDULE FOR SIZE.
RETURN AIR DUCTWHERE SHOWN ONDRAWINGS
FAN COIL UNIT SEE SCHEDULE FORSIZE INFO AND MECH. DRAWINGSFOR IDENTIFICATION AND LOCATION.
SUPPLY DUCT(SEEDRAWINGSFOR SIZE)
FLEX CONNECTION
1" AUXILIARY DRAINOUTLET. SEEDRAWINGSFOR ROUTING ANDDROP LOCATIONS.
COOLING/HEATING COIL SECTION.SEE PIPING CONNECTION DETAIL
FAN SECTION
FLEXCONNECTION
1/2" ALLTHREAD ROD WITHWASHERS AND DOUBLE HEXNUTS (TYPICAL OF 4)PROVIDE RUBBER ISOLATOR
RETURN AIR PLENUM WITH 1" INTERNALSOUND LINING. PLENUM SHALL BE UNITSIZE (HEIGHT, WIDTH AND LENGTH) ORAS INDICATED ON MECHANICAL DRAWINGS.FILTER SECTION. PROVIDEACCESS SPACE FORFILTER REMOVAL (SIDEOR BOTTOM.
VENTILATION AIR DUCT WITHMANUAL BALANCING DAMPER.(SEE DRAWINGS FOR SIZE)
2" DEEP AUXILIARY DRAIN PAN UNDER UNIT. 4"WIDER THAN UNIT ON EACH SIDE. BOTTOM OFPAN TO BE CROSS-BROKEN IN SUCH A MANNERAS TO DIRECT THE WATER FLOW TOWARD THE OUTLET.CONSTRUCT DRAIN PAN OF ALL WELDED 18 GA.GALVANIZED SHEETMETAL OR FURNISH MANUFACTURERSPREFABRICATED AUX. DRAIN PAN. (MIN 18 GA.)
MAIN DUCT(SEE PLANSFOR SIZE)
3'-0" MINIMUMSTRAIGHTLENGTHOF DUCT
AIR TERMINAL UNIT
HANGER STRAPS WITHTHREE (3) SHEETMETAL SCREWS (MIN)
LOW VELOCITY DUCT(SEE PLANS FOR SIZE)
2'-0" MAXIMUM LENGTHOF FLEX CONNECTION(SEE PLANS FOR SIZE)
PROVIDE MINIMUM 1-1/2INLET DUCT DIAMETERSTRAIGHT LENGTH OF HARDDUCT BEFORE INLETCONNECTION TO BOX
NOTE:FLEXIBLE DUCTWORK SHALL NOTPASS THROUGH WALLS-TO-DECK.
TO STARTER FORAUTOMATICSHUTDOWN
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:0
6 P
M
05.22.2015
1309100
M-501
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALDETAILS
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
1/8" = 1'-0"M-5011 2-WAY COIL PIPING DETAIL
1/8" = 1'-0"M-5012 ACOUSTIC ELBOW ON RA GRILLES
NOT TO SCALEM-5013 BOILER RELIEF VALVE
NOT TO SCALEM-5014 BRANCH DUCT
1/8" = 1'-0"M-5015 COOLING TOWER DETAIL
NOT TO SCALEM-5016 COOLING TOWER SUPPORT
1/8" = 1'-0"M-5017 DIFFUSER CONNECTION DETAIL
NOT TO SCALEM-5018 DUCT CONNECTION AT FAN COIL UNIT
NOT TO SCALEM-5019 DUCT CONNECTION TO AIR TERMINAL UNIT
1/8" = 1'-0"M-50110 DUCT SMOKE DETECTOR WIRING FOR AHU SHUTDOWN
WALL
SEAL WALL PENETRATION
"T" FITTING
USE TYPE 'L' HARD DRAWNCOPPER ONLY
ROOF LEVEL
"T" FITTING
CLEANOUT
SLOPE
AIR HANDLER
CLEAN OUT
P-TRAP
SCH 40 PVC BELOW ROOF
LOWPRESSUREDUCT
ROUND TOROUNDREDUCER
CONICALTAPFITTING
ROUND DUCT AND FLEX.REFER TO REHEAT BOXSCHEDULE FOR RUNOUTSIZE
TRANSITION FROM BOXCONNECTIONSIZE TO DUCT SIZE INDICATED ONDRAWINGS OR BOX SCHEDULERECTANGULAR MEDIUM
PRESSURE TRUNK DUCT
4'-0" MAX. LENGTHFLEXIBLE DUCT
SEE PIPINGDETAIL FORCONNECTION TOHEATING COILS
FAN POWEREDBOX
FAN
NOTES:1. FLEX DUCT TO ALLOW ONE BEND WITH CENTERLINE RADIUS NOT LESS
THAN 1 1/2 DUCT DIAMETERS.2. TAP FITTING TO RECTANGULAR MEDIUM PRESSURE DUCT MAY ALSO BE
RECTANGULAR 45 ENTRY, SIZED PER SMACNA RECOMMENDATIONS, ANDTHEN TRANSITION TO ROUND.
3. MEDIUM PRESSURE ROUND TRUNK DUCT TO HAVE CONICAL TEE FITTING,WITH OTHER REQUIREMENTS AS SHOWN.
4. BOXES 1,400 CFM OR LESS TO BE SUPPORTED WITH 1 1/2" X 1/2" GALVANIZEDBAND IRON ON FOUR CORNERS. BOXES GREATER THAN 1,400 CFM SHALL HAVETRAPEZE SUPPORT OF REINFORCING ANGLE WITH 3/8" GALVANIZEDALLTHREAD ROD HANGERS.
5. COORDINATE REQUIREMENT FOR CEILING ACCESS PANELS WITH DIVISION 8.
DAMPER MUSTBE SELF-SUPPORTINGINDEPENDENT OFDUCT
SHEET METALSCREWS ORWELDED 8" ONCENTER
DAMPER SLEEVEMUST EXTENDCLEAR THROUGHWALL 1 1/2"x1 1/2"x 1/8"
RETAINING ANGLE AT TOP,BOTTOM & SIDE ON BOTHSIDES OF WALL. ATTACH TOSLEEVE ONLY.
WALL
CUT WALL OPENING 1/8" LARGER THAN OVERALLDAMPER AND SLEEVE ASSEMBLY.PROVIDE STUD FRAMING ON ALL SIDES.
FIREDAMPER
STOP INSULATION AT WALL
ACCESS DOOR
0% OBSTRUCTION OFFIRE DAMPER BLADE &SUPPORT ASSEMBLYINTO AIR STREAM
COLLAR
WALL
DUCT
PIPE SPACER OVERCLEVIS BOLT
PIPE SPACER OVERCLEVIS BOLT
TYPICAL HANGERS FOR CHILLED AND CONDENSER WATER PIPES
TYPICAL HANGERS FOR HOT WATER PIPES
PROTECTIONSADDLE TACK WELDTO PIPE FILL WITHINSULATION
SEE STRUCTUREATTACHMENTDETAILS FORMETHODS OFSECURING HANGERS
8" & OVER6" & UNDER
8" & OVER6" & UNDER
NOTE:OMIT INSULATION & CALCIUM SILICATE FOR NON-INSULATED
PIPES.
PIPE ROLLER
PIPE
PIPE
PIPE ROLLER
FORGED STEEL CLEVISHANGER
INSULATION
20 GAUGESHIELD
ADJUSTABLESOCKET
CALCIUM SILICATE INSERT
HANGER RODS
PIPE
FORGED STEEL CLEVISHANGER
INSULATION
20 GAUGESHIELD
CALCIUM SILICATE INSERT
HANGER RODS
PIPE
ADJUSTABLESOCKET
FLUE GAS CONNECTION(SEE DETAIL). SIZE NOTLESS THAN CONNECTIONSIZE.
NOTE:DO NOT OPERATE BOILERWATER BELOW 160°F.
REDUCE TO CONNECTIONSIZE (IF REQUIRED) ATTHIS POINT
OS&Y RISING STEMGATE VALVE (TYPICAL)
DRAIN PIPEFULL SIZETO FLOORDRAIN
PRESSUREREGULATING VALVE
GAS VALVE
PIPE RELIEF VALVE(S) FULLCONNECTION SIZE THRU ROOF.USE DRIP PAN ELBOW AT TURNUP THRU ROOF.
TEMPERATURE ANDPRESSURE GAUGE
THERMOMETER(TYPICAL)
UNION(TYP.)
BOILER
GASCOCK
CHECKVALVE
CIRCULATINGPUMP
4" CONCRETE PAD
CONTROLVALVE
HWRHWS
BUTTERFLY VALVE (TYPICAL)(BALL VALVE IF LESS THAN2" SIZE)
GAUGE AND1/4" SHUT-OFFCOCK
REDUCING TEECOMPANION FLANGE TYPECONNECTIONS. (INSTALLPIPE SO PUMP CAN BEREMOVED FOR REPAIR).
STRAINERREDUCE FROM PIPELINE SIZE TOCONNECTION SIZE IFREQUIRED (TYPICAL)
REDUCINGTEE
RIGID SUPPORTS TOBUILDING STRUCTURE.REFER TOSPECIFICATIONS
FLOW
MOTOR
AIRFLOW
STEEL HOUSING
BELT GAURDREFER TO HVACDRAWINGSFOR DUCT DIMENSIONS(TYPICAL)
FLEXIBLECONNECTION
3/8" HANGER RODS ATTACHEDSECURELY TO STRUCTURE
FAN MOTOR
MAX. 30°
DRIVEENCLOSURE
SPRING ISOLATOR(TYPICAL OF FOUR)
TRANSITIONTRANSITION
MAX. 45°
NOTE:1. PROVIDE ADEQUATE SEISMIC BRACING TO RESIST ALL LATERAL MOTION.2. REFER TO SMACNA SEISMIC RESTRAINT MANUAL: GUIDELINES FOR MECHANICAL SYSTEMS.
FAN CASING
FLEXIBLE CONNECTION
FASTENINGDEVICE SEENOTE 2
45° MIN; INSTALLBRACING OUTBOARDIF NECESSARY, TYP.
1/2"THREADEDROD, TYP.
SPRINGISOLATOR,REFER TOSPECIFICATION.
MINIMUM POSSIBLE
SUSPENSION CLIPS
FLAT OVAL EQUIVALENT ROUND
ROUND FLAT OVAL INCHES
6" 4x9
7" 5x10
8" 6x11
10" 6x11
12" 7x20
14" 8x22
16" 8x30
ROLL WYE TOWARDDIFFUSER INLETNECK
BALANCING DAMPER
MAIN ROUND DUCT
MAIN SUPPLY DUCT
BALANCING DAMPER
OVAL TO ROUNDTRANSITION
ADJUSTABLE SCREWTYPE STAINLESS STEELCLAMPROUND CONNECTION WITH 3/8"RAISED BEAD SAME DIAMETER ASFLEX CONNECTION.
FLEXIBLE DUCT TODIFFUSER
FLAT OVAL, SEE SCHEDULEFOR EQUIVALENT ROUNDSIZE
MAIN SUPPLY DUCT
SPIN-IN ROUNDCOLLAR WITH 3/8"RAISED BEAD &BALANCING DAMPER
FLEXIBLE DUCTTO DIFFUSER
FLEXIBLE DUCTTO DIFFUSER
ROUND DUCT COLLARWITH 3/8" RAISEDBEAD AND BALANCINGDAMPER
ADJUSTABLE SCREWTYPE STAINLESSSTEEL CLAMP
ADJUSTABLESCREW TYPESTAINLESS STEELCLAMP
"Y" LATERAL FITTING45°
ROUND TAP TO RECTANGULAR MAIN(TAP SMALLER THAN MAIN)
ROUND TAP TO ROUND MAIN
ROUND TAP TO RECTANGULAR MAIN(TAP LARGER THAN MAIN)
2x1
2x1
BALANCINGDAMPER
RETURN/EXHAUSTGRILLE/REGISTER (SEESCHEDULEFOR SIZE)
LAY-IN CEILING TILE
VOLUME DAMPER(PROVIDE ONLYIN DRYWALLCEILING)
3" MINIMUM
24 GA. GALVANIZEDSHEET METAL BOX
INSULATEDFLEXIBLE DUCT(MAX. 5 FT.)
RETURN/EXHAUSTDUCT
"SPIN-IN FITTING WITH MANUALVOLUME DAMPER (NO EXTRACTORUSED)
1" WIDE SECURING STRAP(TYPICAL)
ANGLESTOCK
SHEET METALSCREWS
"TAP-OUT" EITHER SIDE OR BOTTOM OF DUCT.TOP "TAP-OUT" IS NOT ACCEPTABLE WITH BOTTOMTAP, THE GRILLE SHALL NOT BE LOCATED DIRECTLYBELOW THE MAIN DUCT, UNLESS THE GRILLE BEINGSERVED IS THE ONLY GRILLE BEING SERVED.
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:1
0 P
M
05.22.2015
1309100
M-502
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALDETAILS
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
NOT TO SCALEM-5021 EQUIPMENT CONDENSATE DRAIN DETAIL
NOT TO SCALEM-5022 FAN POWERED AIR TERMINAL UNIT WITH HOT WATER REHEAT
NOT TO SCALEM-5023 FIRE DAMPER
1/8" = 1'-0"M-5024 HOT AND CHILLED WATER PIPE HANGER (SINGLE PIPES)
NOT TO SCALEM-5025 HOT WATER BOILER
NOT TO SCALEM-5026 IN-LINE CIRCULATING PUMP
NOT TO SCALEM-5027 IN-LINE EXHAUST FAN
1/8" = 1'-0"M-5028 IN-LINE FAN SUPPORT
1/8" = 1'-0"M-5029 LOW PRESSURE BRANCH DUCT CONNECTIONS
NOT TO SCALEM-50210 LOW PRESSURE DUCTWORK CONNECTION TO RETURN/EXHAUST GRILLE
P
MBD TO BE LOCATED AT DUCT BRANCH CONNECTION ABOVEACCESSIBLE CEILING WHERE POSSIBLE. INSTALL ACCESSPANEL IN HARD CEILING WHERE DAMPER IS REQUIRED TO BEINSTALLED ABOVE HARD CEILING.
RETURN MAIN
ACCESS PANEL FORMBD WHERE REQUIRED.
CHASE
REFER TO HVAC DRAWINGSFOR BRANCH DUCT SIZE.RETURN/EXHAUST GRILLE.SEE DRAWINGS FOR SIZEAND AIR QUANTITIES (NOMBD IN FACE OF GRILLE).
7" A.F.F.
CEILING
INSTALL MINIMUM 2"SECTION OF INSULATION ATHANGER FOR LIQUID LINE
INSULATION
PIPE
1/2" WIDE COPPER STRAP NOTE:ATTACH HANGER TOBUILDING STRUCTURE
G
G
G
G
M
M
CHILLER
F.F.
MOTORIZED VALVETYPICAL
GATE ORBUTTERFLY VALVE
FLEXIBLE PIPECONNECTION (TYP.)
TEST PORT(TYPICAL)
3/4" DRAIN VALVE WITHHOSE CONN. AND CAP(TYP.)
MECHANICAL GROOVED TYPECONNECTIONS OR MARINE WATER BOXAS INDICATED ON DWG. OR SPEC.(TYPICAL)
CONCRETE PADRE: SPECIFICATIONSFOR PAD SIZE
THERMOMETER GAUGE (TYPICAL)
PRESS. GAUGE (TYPICAL)
VENT TO ATMOSPHERE
SEE RUPTURE DISC DETAIL
CONNECT TO COMPRESSORRUPTURE DISC OUTLET
VIBRATION ISOLATORS
TRANSITION DUCT AS REQUIREDTO CONNECT TO FAN DAMPERTRAY
GRAVITY OR MOTORIZEDBACKDRAFT DAMPER ASSPECIFED. USE OF IN AIRSTREAMDAMPER MOTOR IS ACCEPTABLE,UNLESS NOTED OTHERWISE.
FIRESTAT MOUNTED IN EXHAUSTAIRSTREAM, WHERE SPECIFIED.
FLASH AND COUNTERFLASHINTO ROOFING MEMBRANE RE:ARCHITECTURAL ROOFINGDETAILS.
INSUALTED, GASKETED ROOFCURB. SECURE CURB TOSTRUCTURE WITH APPROPRIATEFASTENERS 12" OC (MINIMUM 2 PERSIDE, AS REQUIRED)
SECURE FAN TO CURB WITHSHEETMETAL SCREWS 12" OC(MINIMUM 2 PER SIDE, ASREQUIRED)
MESH BIRDSCREEN
ROOF MOUNTEDCENTRIFUGALEXHAUST FAN
FLASHING
12"
TERMINAL BOX BRANCH DUCT SCHEDULE
0-1700
AIRFLOW
CFM RANGE
DUCT SIZE
0-700
6"
0-400
10"
0-1200
8"
FLOWAIR
CONTROL BOX
SIDE VIEW
CONTROL BOX
TOP VIEW
STAINLESS STEEL WORM DRIVECLAMPS
SHEET METAL DUCT RUN-OUT SHALL BE SIZED ASSHOWN IN THE TABLE EXCEPT WHERE SHOWNDIFFERENT ON DRAWINGS. PROVIDE TRANSITIONTO FLEX IF REQUIRED.
INSTALL A MIN. OF 2 DIAMETERS OFSTRAIGHT RUN OF SHEET MEATL ATINLET OF BOX.
24" MAX. FLEX DUCT CONN.
INSULATED FLEX DUCT SHALL BESIZE OF INLET ON BOX.
90 DEGREE OF 45 DEGREE CONICALTAP. REFER TO PLAN.
DUCT STRAP. SUPPORTPER SPEC.
PIPE TO FLOORDRAIN
HOUSEKEEPING PAD
MAKE-UP WATER WITH BACKFLOW PREVENTER (REFER TOPLUMBING DRAWINGS)
RELIEF VALVE
SYSTEMCONNECTION
BMS PRESSURESWITCH
CHARGINGCONNECTION
LIFT RING
SIGHTGLASS
FULL SIZE BYPASS
SHUT-OFF VALVE
NOTE:
1. SUPPORT FLEX DUCT FROM STRUCTURE SOTHAT IT DOES NOT KINK, SAG OR REST ONLIGHT FIXTURES, CEILING SUPPORT TEES OR TILE.
GYP. BD CEILING
SLOT DIFFUSER
INSULATED SHEET METAL SUPPLY PLENUM FOR LINEAR SUPPLY SLOTS.REFER TO PLANS AND AIR DEVICE SCHEDULE FOR SIZES.
HANGER WIRE TABS FOR SUPPORTTO STRUCTURE AS REQUIRED.
SUPPLY AIR DUCT
SPIN IN TAPW/VOLUME DAMPER
INSULATED FLEXDUCT. MAX. 8 FT.LENGTH
1/2'' BOARD EDGE INSULATION
CABLEBINDERSOR STARCLIPS
FLOOR COVERING
POURED CONCRETE SLABTUBE AND CLIPS
WIRE MESHPOLYETHYLENE SHEETING
INSULATIONBOARD
CONCRETESLAB
TUBE SPACING (SEE SCHEDULE)
SUPPLY HEADER
RELIEF AIRVENT (TYP)
BALANCINGVALVES
SHUT OFFVALVES
RETURNHEADER
3/4''PEXTUBING
PIPESHIELD
FLOORCOVERING
FRONT VIEW SIDE VIEW
30''MAX
6''MAXCAP
NOT TO SCALEM-5031 LOW RETURN/EXHAUST
NOT TO SCALEM-5032 REFRIGERANT PIPING HANGER
1/8" = 1'-0"M-5038 TYPICAL CHILLER PIPING CONNECTION DETAIL
1/8" = 1'-0"M-5033 TYPICAL ROOF EXHAUST FAN
1/8" = 1'-0"M-5039 VAV TERMINAL UNIT DETAIL
1/8" = 1'-0"M-5034 VERTICAL EXPANSION TANK
1/8" = 1'-0"M-5035 TYPICAL SLOT DIFFUSER
1/8" = 1'-0"M-5036 RADIANT FLOOR CONSTRUCTION
1/8" = 1'-0"M-5037 RADIANT FLOOR MANIFOLD
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:1
3 P
M
05.22.2015
1309100
M-503
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALDETAILS
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
AIR HANDLING UNIT SCHEDULE
AHU NEWDESIGNATION SYSTEM QTY
MANUF.MODEL
NUMBER
OU
TSID
E AI
R C
FM(A
SHR
AE 6
2.1
+ 30
%R
equi
rem
ent)
SUPPLY FAN ARRAY RETURN FAN ARRAY HYDRONIC COOLING HYDRONIC HEATING COIL AIR FILTER INTERNALVIBRATION ISOLATION
ELECTRICALDATA
OPTIONALSTANDBYPOWER
LIFE-SAFETYEMERGENCY
POWER
OPERATINGWEIGHT
(LBS)NOTES TOTAL
AIRFLOW(CFM)
EXT.
S.P
.(IN
. WG
.)
RPM
QTY
FAN
S
BHP
(EAC
H)
MO
TOR
HP
(EAC
H)
BHP
(TO
TAL)
MO
TOR
HP
(TO
TAL)
TOTALAIRFLOW
(CFM)
EXT.
S.P
.(IN
. WG
.)
RPM
QTY
FAN
S
BHP
(EAC
H)
MO
TOR
HP
(EAC
H)
BHP
(TO
TAL)
MO
TOR
HP
(TO
TAL) EAT LAT CAPACITY
GPM
EWT
(ºF)
LWT
(ºF)
P.D
, AIR
(IN. W
G.)
P.D
. WAT
ERFT
. H2O
VELO
CIT
Y(F
PM)
EAT LAT CAPACITY
GPM
EWT
(ºF)
LWT
(ºF)
P.D
, AIR
(IN. W
G.)
P.D
. WAT
ERFT
. H2O
VELO
CIT
Y(F
PM)
SPEC
.TY
PE
FAC
EVE
LOC
ITY
FPM
MER
V (P
RE/
FIN
AL) P.D.
(IN. WG.) BASE ISOLATION
VOLT
AGE/
PHAS
E
UN
ITFL
A
DB
(ºF)
WB
(ºF)
DB
(ºF)
WB
(ºF)
TOTA
LM
BH
SEN
SIBL
EM
BH
DB
(ºF)
DB
(ºF)
TOTA
LM
BH
INIT
IAL
FIN
AL
SPEC
.TY
PE
THIC
KNES
S(IN
CH
ES)
SPEC
.TY
PE
STAT
ICD
EFLE
CTI
ON
(INC
HES
)
AHU-R-1 OFFICE EAST 1 15,000 60,000 4.5 1,750 6 10.0 10 60.0 60 60,000 2.5 1,150 6 7.1 7.5 42.6 45 80 63 52 50 2192 1814 370 44 56 0.67 7.20 500 45 70 1620 170 140 120 0.20 2.40 500 500 8 / 13 -- -- 2 460/3 206.5 -- -- 1, 2
AHU-R-2 OFFICE WEST 1 15,000 60,000 4.5 1,800 6 10.0 10 60.0 60 60,000 2.5 1,200 6 7.1 7.5 42.6 45 80 63 52 50 2192 1814 370 44 56 0.67 7.20 500 45 70 1620 170 140 120 0.20 2.40 500 500 8 / 13 -- -- 2 460/3 206.5 -- -- 1, 2
AHU-R-3 COURTROOM EAST 1 8,000 20,000 4.5 1,583 2 10.0 10 20.0 20 20,000 2.5 1,261 2 7.5 8 15.0 15 80 63 52 50 731 605 130 44 56 0.65 7.42 500 45 70 540 60 140 120 0.19 5 500 500 8 / 13 -- -- 2 460/3 75.5 -- -- 1, 2
AHU-R-4 COURTROOM WEST 1 8,000 20,000 2.5 1,800 2 14.1 15 28.1 30 20,000 2.5 1,261 2 7.5 8 15.0 15 80 63 52 50 731 605 130 44 56 0.65 7.42 500 45 70 540 60 140 120 0.19 5 500 500 8 / 13 -- -- 2 460/3 75.5 -- -- 1, 2GENERAL NOTES:A) PROVIDE SEPARATE VFDS ON ALL FANSB) PROVIDE SINGLE POINT ELECTRICAL CONNECTION WITH DISCONNECTC) PROVIDE WITH SEPARATE 120V CONNECTION FOR CONVENIENCE RECEPTACLES AND LIGHTSD) PROVIDE HEATING COIL IN THE PREHEAT CONFIGURATIONE) PROVIDE ALL FANS WITH FAN INLET AIRFLOW MONITORING AND DIGITAL DISPLAY ON THE CASING OF THE UNITF) PROVIDE UNITS WITH FAN ARRAY FOR SUPPLY AND RETURN. SEE FAN QTY FOR MINIMUM FANS INCLUDED IN ARRAY.
NUMBERED NOTES:1) PROVIDE DUCT SMOKE DETECTOR ON RETURN AIR DUCT TO AIR HANDLER2) PROVIDE AIR HANDLING UNIT WITH FULL AIRSIDE ECONOMIZER
NATURAL GAS CONDENSING BOILER SCHEDULE
DESIGNATION LOCATION BASIS OF DESIGN TYPE
INPUTRANGE
MAXIMUMOUTPUT GPM
(MAX)
EWT LWTMAX
ALLOWABLEPRESSURE THERMAL
EFFICIENCY
FLUESIZE FLUE TYPE
ELECTRICALOPERATING
WEIGHT(LBS)
AMPS VOLTAGE NOTES
(MBH) (MBH) (°F) (°F) (PSIG) (IN)
B1 BASEMENT MECH AERCO BENCHMARK 2000 NATURAL GAS 2000 1,900 350 100 120 160 94.6% 8 AL29-4 POLYPRO 16 120 1,760
B2 BASEMENT MECH AERCO BENCHMARK 2000 NATURAL GAS 2000 1,900 350 100 120 160 94.6% 8 AL29-4 POLYPRO 16 120 1,760
NOTES:(1)
CHILLER SCHEDULE
DESIGNATION BASIS OFDESIGN TYPE REFRIGERANT
EVAPORATOR BUNDLE CONDENSER BUNDLECOOLING MODE
ELECTRICAL DATA
STAND-BY POWER
OPER.WEIGHT
REMARKSCAPACITY EFFICIENCY EVAPORATOR CONDENSER
FOULING FACTOR NO OFPASSES
PRESS.RATING(PSIG)
FOULING FACTOR NO OFPASSES
PRESS.RATING(PSIG)
EWT LWT GPM PD EWT LWT GPM PDVOLTAGE/ PHASE MCA MOCP STARTER(TONS) FULL LOAD (kW/TON) IPLV
(kW/TON) (°F) (°F) (FT H20) (°F) (°F) (FT H20)NOTE 3 (LBS)
CH-1 CARRIER 23XRV SCREW R-134A 0.00010 2 150 0.00025 2 150 200 0.492 0.34 56 44.0 400 13.1 76.0 86.0 548 15.9 460 / 3 191 300 WYE-DELTA NO 15,000
CH-2 CARRIER 23XRV SCREW R-134A 0.00010 2 150 0.00025 2 150 200 0.492 0.34 56 44.0 400 13.1 76.0 86.0 548 15.9 460 / 3 191 300 WYE-DELTA NO 15,000NOTES:
COOLING TOWER SCHEDULE
DESIGNATION LOCATION BASIS OF DESIGNCAPACITY AMBIENT
WET BULB EWT LWT DESIGN FLOW MIN FLOW MAX PD HEATER (2) FAN MOTOR STAND-BYPOWER AIC
OPERATINGWEIGHT NOTES
(CT TONS) (MBH) (°F) (°F) (°F) (GPM) (GPM) (FT H20) KW VOLTAGE/PHASE HP VOLTAGE/PHASE [LBS]
CT-1 N PARKING LOT BALTIMORE AIRCOIL S3E-1020-07M 400 5,480 66 86 76 1,096 13.86 8 460/3 20 460/3 NO 21,000 1,2NOTES:(1) EQUIP UNIT WITH FAN VFD, BASIN HEATER.(2) CONNECT BASIN HEATER TO STANDBY POWER
DEDICATED OUTSIDE AIR SYSTEM SCHEDULE
DESIGNATION LOCATION/SERVICE MANUF. MODELNUMBER
TOTAL AIRFLOWCFM
SUPPLY FAN EXHAUST FAN PLATE AND FRAME ENERGY RECOVERY AIR FILTER ELECTRICAL DATA
NOTES
CFM
EX
T SP
IN. W
G
MO
TOR
HP
CFM
EX
T SP
IN. W
G
MO
TOR
HP
SUMMER WINTER
PD
IN W
G. (
INIT
IAL)
PD
IN W
G. (
FIN
AL)
SU
P. F
ILTE
R (M
ER
V)
RE
T. F
ILTE
R (M
ER
V)
VO
LTA
GE
/ PH
AS
E
MC
A (A
MP
S)
MO
CP
(AM
PS
)
WEIGHT(LBS)
EA
T (F
)
LAT
(F)
EFF
ICIE
NC
Y
CA
PAC
ITY
(MB
H)
EA
T (F
)
LAT
(F)
EFF
ICIE
NC
Y
CA
PAC
ITY
(MB
H)
DOAS-R-1 ROOF / DOAS 23000 23000 1 7.5 23000 1.5 7.5 86 80 64% 149.0 21 51 64% 745.2 8 8 460/3 58.3 80 1, 2
DOAS-R-2 ROOF / DOAS 23000 23000 1 7.5 23000 1.5 7.5 86 80 64% 149.0 21 51 64% 745.2 8 8 460/3 58.3 80 1, 2GENERAL NOTES:A) PROVIDE SEPARATE VFDS FOR ALL FANSB) PROVIDE WITH FACTORY MOUNTED INTERNAL SPRING ISOLATIONC) PROVIDE WITH SEPARATE 120V CONNECTION FOR LIGHTS AND CONVENIENCE OUTLETSD) PROVIDE ALL FANS WITH FAN INLET AIRFLOW MONITORING AND DIGITAL DISPLAY ON THE CASING OF THE UNITE) SUMMER HEAT RECOVERY BASED ON RETURN AIR TEMPERATURE OF 78F. WINTER HEAT RECOVERY BASED ON RETURN AIR TEMPERATURE OF 68F.
NUMBERED NOTES:1) PROVIDE DUCT SMOKE DETECTOR FOR RETURN AIR DUCTWORK.2) PROVIDE WITH UNIT MOUNTED OUTDOOR AIR AND EXHAUST AIR DAMPERS.
INTAKE / RELIEF HOOD SCHEDULE
DESIGNATIONMANUF.MODEL
NUMBERSERVICE AIRFLOW
(CFM)
STATICPRESSURE
(IN WG)
THROATAREA(SF)
THROAT SIZE NOTES
RH-4-1 GREENHECK WRH RELIEF 700 0.03 1.8 16X16 NOTE 1
IH-4-1 GREENHECK WRH OA INTAKE 700 0.03 1.8 16X16 NOTE 1NUMBERED NOTES:1) PROVIDE WITH PREFABRICATED ROOF CURB SIZED TO PROVIDE 6" CLEAR ABOVE INSULATION
PUMPS
DESIGNATIONMANUF.MODEL
NUMBERLOCATION/SERVICE TYPE GPM
HEAD(FT
H2O)
MINIMUMEFFICIENCY(PERCENT)
CASINGPRESSURE
(PSIG) RPM
MOTOR
EMERG.POWER
OPER.WEIGHT
(LBS)VAR.
SPEED NOTES
BRAK
EH
P
NO
N-
OVE
RLO
ADIN
GH
P
VOLT
AGE/
PHAS
E
HWP-1 BELL&GOSSETTE-1510 2EB BASEMENT MECH / HOT WATER CENTRIFUGAL 200 80 71% 175 1,750 5.81 7.5 460/3 N 375 Y
HWP-2 BELL&GOSSETTE-1510 2EB BASEMENT MECH / HOT WATER CENTRIFUGAL 200 80 71% 175 1,750 5.81 7.5 460/3 N 375 Y
HWP-3 BELL&GOSSETTE-1510 2EB BASEMENT MECH / HOT WATER CENTRIFUGAL 200 80 71% 175 1,750 5.81 7.5 460/3 N 375 Y
CWP-1 BELL&GOSSETTE-1510 3BD
BASEMENT MECH /CONDENSER WATER CENTRIFUGAL 550 50 80% 175 1,770 8.85 10 460/3 N 370 Y
CWP-2 BELL&GOSSETTE-1510 3BD
BASEMENT MECH /CONDENSER WATER CENTRIFUGAL 550 50 80% 175 1,770 8.85 10 460/3 N 370 Y
CWP-3 BELL&GOSSETTE-1510 3BD
BASEMENT MECH /CONDENSER WATER CENTRIFUGAL 550 50 80% 175 1,770 8.85 10 460/3 N 370 Y
CHWP-1 BELL&GOSSETTE-1510 3EB
BASEMENT MECH /CHILLED WATER CENTRIFUGAL 400 80 76% 175 1,750 10.68 15 460/3 N 450 Y
CHWP-2 BELL&GOSSETTE-1510 3EB
BASEMENT MECH /CHILLED WATER CENTRIFUGAL 400 80 76% 175 1,750 10.68 15 460/3 N 450 Y
CHWP-3 BELL&GOSSETTE-1510 3EB
BASEMENT MECH /CHILLED WATER CENTRIFUGAL 400 80 76% 175 1,750 10.68 15 460/3 N 450 Y
RFP-1 BELL&GOSSETTECOCIRC XL 36-45 RADIANT FLOOR CIRCULATION INLINE 18 15 175 1/6 120/1 N 20 N
GENERAL NOTES:A) NOT USED
RADIANT FLOOR ZONE SCHEDULE
ZONE TAG ZONE AREA(SQFT) MANIFOLD
HEATING TUBING
REMARKSSPACE STPT(F)
FLOORSURFACE
(F)
BTU/HPER
SQFTTOTALMBH
EWT(F)
LWT(F) GPM HEAD LOSS
(FT) TYPE SPACINGOC
NUMBEROF LOOPS
LOOPLENGTH
(FT)
RFS-2-1 MAIN LOBBY 2300 RFM-2-1 70 85 35 80.5 100 90 18 He-Pex 5/8"
GENERAL NOTES:A) BASED ON 4" TOPPING SLAB
NUMBERED NOTES:1) NOT USED
ROOFTOP PACKAGED HEAT PUMP
DESIGNATION LOCATION /SERVICES
MANUF.MODEL
NUMBER
TOTALAIRFLOW
CFM
SUPPLY FAN
RE
FRIG
ER
AN
T
COMPRESSORSECTION
AIR COOLED CONDENSER AIR FILTER
HSPF
ELECTRICALDATA
EMERGENCYPOWER
VAR.SPEED(Y/N)
OPERATINGWEIGHT
(LBS)NOTES
CFM
EXT.
S.P
.(IN
. WG
.)
RPM BH
P
MO
TOR
HP
FANS
TOTA
L AR
EA(S
Q. F
T.)
AM
BIEN
TTE
MP.
DB
(°F)
SP
EC.
TYPE
FAC
EV
ELO
CIT
YFP
M
PD (IN.WG.)
AS
HR
AE
52.2
-199
9M
ER
V
VO
LTAG
E/PH
ASE
UN
ITFL
A
NU
MBE
R
CAP
ACIT
Y(M
BH)
HP
NO
.
TYPE
RPM HP
INIT
IAL
FIN
AL
PHP-R-1 ROOF/EMR COOLING CARRIER 50VR-A36 1200 1200 0.25 1000 0.0 3/4 R-410A 1 34 0/0 0 X 0 0/0 0 0 X 0 0.0 0.0 0 8.00 208/1 6 N Y 500PHP-R-2 ROOF/EMR COOLING CARRIER 50VR-A36 1200 1200 0.25 1000 0.0 3/4 R-410A 1 34 0/0 0 X 0 0/0 0 0 X 0 0.0 0.0 0 8.00 208/1 6 N Y 500
NOTES:
SPLIT SYSTEM INDOOR UNIT SCHEDULE
DESIGNATION CORRESPONDINGOUTDOOR UNIT SERVICE
MANUF.MODEL
NUMBERUNIT TYPE
SUPPLYAIRFLOW
(CFM)ESP
(IN. WG.)
COOLING ELECTRICAL
STANDBYPOWER
(Y/N)WEIGHT
(LBS) NOTESCAPACITY EAT LAT
MC
A
VOLT
AGE
/PH
ASE
TOTA
LBT
UH
SEN
SIBL
EBT
UH
DB
(°F)
WB
(°F) DB
(°F)
WB
(°F)
FCU-B-1 HP-1 CONTROL EQUIPMENT ROOM PEFY-P54NMAU-E DUCTED 1480 0.6 54,000 54,000 85 75 52 52 3.31 208 / 1 Y 102
FCU-B-2 HP-5 CONTROL EQUIPMENTBACK-UP PEFY-P54NMAU-E DUCTED 1480 0.6 54,000 54,000 85 75 52 52 3.31 208 / 1 Y 102 NOTE 1
FCU-B-3 HP-1 BASEMENT NORMAL POWER PKFY-P24NKMU-E WALL MOUNTED 710 0.6 24,000 24,000 85 75 54 52 0.37 208 / 1 Y 64
FCU-B-4 HP-1 MDF BASEMENT PEFY-P72NMAU-E DUCTED 2000 0.6 72,000 72,000 85 75 52 52 4.94 208 / 3 Y 221
FCU-1-1 HP-1 LEVEL 1 IDF PEFY-P54NMAU-E DUCTED 1480 0.6 54,000 54,000 85 75 52 52 3.31 208 / 1 Y 102
FCU-1-2 HP-2 LEVEL 1 IDF SOUTH PKFY-P18NKMU-E WALL MOUNTED 500 0.6 18,000 18,000 85 75 52 52 0.37 208.0 Y 53
FCU-1-3 HP-2 LEVEL 1 WEST ELEC PKFY-P24NKMU-E WALL MOUNTED 710 0.6 24,000 24,000 85 75 54 52 0.37 208 / 1 Y 64
FCU-2-1 HP-2 LEVEL 2 IDF PEFY-P54NMAU-E DUCTED 1480 0.6 54,000 54,000 85 75 52 52 3.31 208 / 1 Y 102
FCU-2-2 HP-2 LEVEL 2 IDF SOUTH PKFY-P18NKMU-E WALL MOUNTED 500 0.6 18,000 18,000 85 75 52 52 0.37 208 / 1 Y 53
FCU-2-3 HP-2 LEVEL 2 WEST ELEC PKFY-P24NKMU-E WALL MOUNTED 710 0.6 24,000 24,000 85 75 54 52 0.37 208 / 1 Y 64
FCU-3-1 HP-2 LEVEL 3 IDF PEFY-P54NMAU-E DUCTED 1480 0.6 54,000 54,000 85 75 52 52 3.31 208 / 1 Y 102
FCU-3-2 HP-3 LEVEL 3 IDF SOUTH PKFY-P18NKMU-E WALL MOUNTED 500 0.6 18,000 18,000 85 75 52 52 0.37 208 / 1 Y 53
FCU-3-3 HP-3 LEVEL 3 EAST ELEC PKFY-P24NKMU-E WALL MOUNTED 710 0.6 24,000 24,000 85 75 54 52 0.37 208 / 1 Y 64
FCU-3-4 HP-3 LEVEL 3 SECURITY PKFY-P24NKMU-E DUCTED 710 0.6 24,000 24,000 85 75 54 52 0.96 208 / 1 Y 64
FCU-4-1 HP-3 LEVEL 4 IDF PEFY-P54NMAU-E DUCTED 1480 0.6 54,000 54,000 85 75 52 52 3.31 208 / 1 Y 102
FCU-5-1 HP-3 LEVEL 5 IDF PEFY-P54NMAU-E DUCTED 1480 0.6 54,000 54,000 85 75 52 52 3.31 208 / 1 Y 102
FCU-6-1 HP-4 LEVEL 6 IDF PEFY-P54NMAU-E DUCTED 1480 0.6 54,000 54,000 85 75 52 52 3.31 208 / 1 Y 102
FCU-7-1 HP-4 LEVEL 7 IDF PEFY-P54NMAU-E DUCTED 1480 0.6 54,000 54,000 85 75 52 52 3.31 208 / 1 Y 102
FCU-7-2 HP-4 LEVEL 7 WEST ELEC PKFY-P24NKMU-E WALL MOUNTED 710 0.6 24,000 24,000 85 75 54 52 0.37 208 / 1 Y 64
FCU-8-1 HP-4 LEVEL 8 IDF PEFY-P54NMAU-E DUCTED 1480 0.6 54,000 54,000 85 75 52 52 3.31 208 / 1 Y 102
FCU-8-2 HP-4 LEVEL 8 WEST ELEC PKFY-P24NKMU-E WALL MOUNTED 710 0.6 24,000 24,000 85 75 54 52 0.37 208 / 1 Y 64GENERAL NOTES:A) BASIS OF DESIGN FOR FCU IS MITSUBISHI CITY MULTIB) SEE ACC SCHEDULE FOR SYSTEM EFFICIENCYC) PROVIDE UNITS WITH INTEGRAL CONDENSATE PUMPD) SEPARATE POWER CONNECTION FOR INDOOR AND OUTDOOR UNITSNUMBERED NOTES:1. FCU CONNECTED TO BACK-UP HP UNIT IN LOADING DOCK. PROVDE WITH EMERGENCY POWER.
EXPANSION TANK SCHEDULE
DESIGNATION SERVICE MANUF. MODEL NUMBER TYPETANK VOLUME ACCEPTANCE
VOLUME MIN TEMP MAX TEMP PRESS RATING OPER. WEIGHTREMARKS
GAL GAL °F °F [PSIG] [LBM]
ET-B-1 CHILLED WATER BELL & GOSSETT B-200 BLADDER 53 53 44 80 150 630
ET-B-2 HEATING HOT WATER BELL & GOSSETT B-200 BLADDER 53 53 50 140 150 630
NOTES:
AIR/DIRT SEPARATOR SCHEDULE
DESIGNATION SERVICE MANUF. MODEL NUMBER TYPE FLOW RATE PRESS RATING PRESS DROP OPER. WEIGHT REMARKS
GPM PSIG FT H2O LBMAS-B-1 CHILLED WATER SPIROVENT VDN800 COALESCING 800 125 2
AS-B-2 HEATING HOT WATER SPIROVENT VDN600 COALESCING 400 125 1.4
NOTES:
HYDRONIC COIL SCHEDULE
DESIGNATION LOCATION / SERVICE MANUFACTURER MODEL NUMBER CFM(MAX)
CFM(MIN) GPM CAPACITY
(MBH)
FLUIDTEMPERATURE EAT LAT PRESSURE
DROP SIZE PERCOIL SECTION
W" x H"
TOTALAREA(SF)
ROWS/FINS
PER INNOTES
EWT
(°F)
LWT
(°F)
DB
(°F)
DB
(°F)
AIR
(IN.
WG
.)
FLU
ID(F
TH
2O)
HC-3-1 LEVEL 3 COURT WEST RAE 58W12X15-13-1-C-E-R 600 180 1.7 16.5 140 120 55 80 0.18 0.9 12X15 1.25 1 / 13
HC-3-2 LEVEL 3 COURT EAST RAE 58W12X15-13-1-C-E-R 600 180 1.7 16.5 140 120 55 80 0.18 0.9 12X15 1.25 1 / 13
HC-4-1 LEVEL 4 COURT WEST RAE 58W12X15-13-1-C-E-R 600 180 1.7 16.5 140 120 55 80 0.18 0.9 12X15 1.25 1 / 13
HC-4-2 LEVEL 4 COURT EAST RAE 58W12X15-13-1-C-E-R 600 180 1.7 16.5 140 120 55 80 0.18 0.9 12X15 1.25 1 / 13
HC-5-1 LEVEL 5 COURT WEST RAE 58W12X15-13-1-C-E-R 600 180 1.7 16.5 140 120 55 80 0.18 0.9 12X15 1.25 1 / 13
HC-5-2 LEVEL 5 COURT EAST RAE 58W12X15-13-1-C-E-R 600 180 1.7 16.5 140 120 55 80 0.18 0.9 12X15 1.25 1 / 13
HC-6-1 LEVEL 6 COURT WEST RAE 58W12X15-13-1-C-E-R 600 180 1.7 16.5 140 120 55 80 0.18 0.9 12X15 1.25 1 / 13
HC-6-2 LEVEL 6 COURT EAST RAE 58W12X15-13-1-C-E-R 600 180 1.7 16.5 140 120 55 80 0.18 0.9 12X15 1.25 1 / 13NOTES:1) CAPACITY BASED ON MINIMUM AIRFLOW WITH LISTED ENTERING AND LEAVING AIR TEMPERATURES
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:1
5 P
M
05.22.2015
1309100
M-601
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALSCHEDULES
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
FAN POWERED TERMINAL WITH HOT WATER COIL
DESIGNATION NAILOR MODELNUMBER UNIT INLET DUCT
SIZE (INCHES)
FAN PRIMARYCFM HEATING COIL
VOLTAGE/PHASE NOTES
CFM
ESP
(IN.
WG
)
HP
MAX
IMU
M
MIN
IMU
M
CAP
ACIT
Y (M
BH)
GPM EA
T(°
F)
LAT
(°F)
FPB-B-1 35SST 3 8 220 0.4 1/2 220 200 - - - - 277 / 1 1,2,3
FPB-1-1 35SWST 3 8 100 0.4 1/2 100 200 1.5 0.4 55 75 277 / 1 1,2,3
FPB-1-10 35SWST 3 8 220 0.4 1/2 220 200 2.9 0.4 55 81 277 / 1 1,2,3
FPB-1-11 35SWST 3 8 430 0.4 1/2 430 260 8.2 1.1 55 97 277 / 1 1,2,3
FPB-1-12 35SWST 3 8 380 0.4 1/2 380 230 7.3 1.0 55 97 277 / 1 1,2,3
FPB-1-13 35SWST 3 8 350 0.4 1/2 350 200 4.3 0.6 55 88 277 / 1 1,2,3
FPB-1-14 35SST 3 10 700 0.4 1/2 700 200 - - - - 277 / 1 1,2,3,4
FPB-1-15 35SWST 3 8 150 0.4 1/2 150 200 2.4 0.4 55 79 277 / 1 1,2,3
FPB-1-16 35SWST 3 8 110 0.4 1/2 110 200 2.0 0.4 55 77 277 / 1 1,2,3
FPB-1-17 35SWST 3 8 200 0.4 1/2 200 200 1.9 0.4 55 77 277 / 1 1,2,3,4
FPB-1-18 35SWST 3 8 250 0.4 1/2 250 200 2.2 0.4 55 78 277 / 1 1,2,3
FPB-1-19 35SWST 5 12 1,250 0.4 3/4 1250 780 11.3 1.6 55 81 277 / 1 1,2,3
FPB-1-2 35SWST 3 8 250 0.4 1/2 250 200 4.7 0.6 55 90 277 / 1 1,2,3
FPB-1-20 35SWST 5 12 1,050 0.4 3/4 1050 960 8.5 1.2 55 76 277 / 1 1,2,3,4
FPB-1-21 35SST 5 14 2,150 0.4 3/4 2150 500 - - - - 277 / 1 1,2,3,4
FPB-1-22 35SWST 3 8 370 0.4 1/2 370 280 9.0 1.2 55 98 277 / 1 1,2,3
FPB-1-23 35SWST 3 8 450 0.4 1/2 450 200 6.1 0.8 55 96 277 / 1 1,2,3
FPB-1-24 35SWST 3 8 170 0.4 1/2 170 200 2.7 0.4 55 80 277 / 1 1,2,3
FPB-1-25 35SWST 3 8 450 0.4 1/2 450 200 5.7 0.8 55 94 277 / 1 1,2,3
FPB-1-26 35SST 3 10 680 0.4 1/2 680 200 - - - - 277 / 1 1,2,3,4
FPB-1-27 35SST 3 8 450 0.4 1/2 450 200 - - - - 277 / 1 1,2,3,4
FPB-1-28 35SST 3 10 660 0.4 1/2 660 200 - - - - 277 / 1 1,2,3,4
FPB-1-29 35SST 3 8 450 0.4 1/2 450 200 - - - - 277 / 1 1,2,3,4
FPB-1-3 35SWST 5 12 1,050 0.4 3/4 1050 735 4.9 0.7 55 74 277 / 1 1,2,3,4
FPB-1-30 35SWST 3 8 100 0.4 1/2 100 200 1.6 0.4 55 75 277 / 1 1,2,3
FPB-1-31 35SWST 3 8 200 0.4 1/2 200 200 3.6 0.5 55 84 277 / 1 1,2,3
FPB-1-32 35SWST 3 8 350 0.4 1/2 350 200 4.5 0.6 55 89 277 / 1 1,2,3
FPB-1-33 35SWST 3 8 360 0.4 1/2 360 230 7.4 1.0 55 98 277 / 1 1,2,3
FPB-1-34 35SWST 3 8 320 0.4 1/2 320 200 1.3 0.4 55 74 277 / 1 1,2,3
FPB-1-4 35SWST 3 10 750 0.4 1/2 750 495 3.3 0.5 55 74 277 / 1 1,2,3,4
FPB-1-5 35SWST 3 8 310 0.4 1/2 310 200 5.9 0.8 55 95 277 / 1 1,2,3
FPB-1-6 35SWST 3 8 150 0.4 1/2 150 200 4.8 0.7 55 90 277 / 1 1,2,3
FPB-1-7 35SST 3 10 670 0.4 1/2 670 200 - - - - 277 / 1 1,2,3
FPB-1-8 35SST 3 8 450 0.4 1/2 450 200 - - - - 277 / 1 1,2,3,4
FPB-1-9 35SWST 3 10 920 0.4 1/2 920 630 3.6 0.5 55 73 277 / 1 1,2,3
FPB-2-1 35SWST High CFM 16 3,000 0.4 1 3000 720 23.0 3.2 55 97 277 / 1 1,2,3
FPB-2-10 35SWST 3 10 700 0.4 1/2 700 420 13.3 1.8 55 97 277 / 1 1,2,3
FPB-2-11 35SWST 3 10 700 0.4 1/2 700 250 8.0 1.1 55 97 277 / 1 1,2,3
FPB-2-12 35SWST 3 8 380 0.4 1/2 380 200 3.7 0.5 55 85 277 / 1 1,2,3
FPB-2-13 35SWST 3 8 520 0.4 1/2 520 280 8.9 1.2 55 97 277 / 1 1,2,3
FPB-2-14 35SWST 3 8 210 0.4 1/2 210 200 3.5 0.5 55 84 277 / 1 1,2,3
FPB-2-15 35SWST 3 8 250 0.4 1/2 250 200 4.9 0.7 55 90 277 / 1 1,2,3
FPB-2-16 35SWST 3 8 650 0.4 1/2 650 200 5.8 0.8 55 95 277 / 1 1,2,3
FPB-2-17 35SWST 3 8 600 0.4 1/2 600 200 5.8 0.8 55 95 277 / 1 1,2,3
FPB-2-1A 35SWST 5 14 2,200 0.4 3/4 2200 540 17.4 2.4 55 98 277 / 1 1,2,3
FPB-2-1B 35SWST High CFM 16 3,000 0.4 1 3000 720 23.0 3.2 55 97 277 / 1 1,2,3
FPB-2-1C 35SWST 5 14 1,500 0.4 3/4 1500 500 12.2 1.7 55 90 277 / 1 1,2,3
FPB-2-2 35SWST 5 12 1,100 0.4 3/4 1100 690 5.0 0.7 55 74 277 / 1 1,2,3
FPB-2-3 35SWST 5 12 1,300 0.4 3/4 1300 500 12.6 1.7 55 91 277 / 1 1,2,3
FPB-2-4 35SWST 3 10 900 0.4 1/2 900 360 11.6 1.6 55 98 277 / 1 1,2,3
FPB-2-5 35SWST 3 8 650 0.4 1/2 650 200 5.8 0.8 55 95 277 / 1 1,2,3
FPB-2-6 35SWST 3 8 650 0.4 1/2 650 280 8.8 1.2 55 97 277 / 1 1,2,3,4
FPB-2-7 35SWST 3 10 800 0.4 1/2 800 290 9.1 1.3 55 97 277 / 1 1,2,3
FPB-2-8 35SWST 3 10 900 0.4 1/2 900 219.75 6.2 0.9 55 94 277 / 1 1,2,3
FPB-2-9 35SWST 3 8 250 0.4 1/2 250 200 5.6 0.8 55 94 277 / 1 1,2,3
FPB-3-1 35SWST 5 14 1,350 0.4 3/4 1350 945 6.8 0.9 55 74 277 / 1 1,2,3,4
FPB-3-10 35SWST 3 8 350 0.4 1/2 350 200 5.2 0.7 55 92 277 / 1 1,2,3
FPB-3-11 35SWST 3 8 470 0.4 1/2 470 260 8.2 1.1 55 97 277 / 1 1,2,3
FPB-3-12 35SWST 3 10 880 0.4 1/2 880 300 9.5 1.3 55 97 277 / 1 1,2,3
FPB-3-13 35SWST 3 10 950 0.4 1/2 950 410 13.2 1.8 55 98 277 / 1 1,2,3
FPB-3-14 35SWST 3 8 350 0.4 1/2 350 200 3.0 0.4 55 82 277 / 1 1,2,3
FPB-3-15 35SST 5 12 1,300 0.4 3/4 1300 500 - - - - 277 / 1 1,2,3
FPB-3-16 35SWST 3 8 250 0.4 1/2 250 200 3.1 0.4 55 82 277 / 1 1,2,3
FPB-3-17 35SWST 3 8 250 0.4 1/2 250 200 3.1 0.4 55 82 277 / 1 1,2,3
FPB-3-18 35SWST 3 8 400 0.4 1/2 400 200 5.8 0.8 55 95 277 / 1 1,2,3
FPB-3-19 35SST 3 10 700 0.4 1/2 700 200 - - - - 277 / 1 1,2,3,4
FPB-3-2 35SWST 5 14 1,500 0.4 3/4 1500 1095 7.1 1.0 55 74 277 / 1 1,2,3,4
FPB-3-20 35SST 5 12 1,100 0.4 3/4 1100 500 - - - - 277 / 1 1,2,3,4
FPB-3-21 35SST 5 12 1,250 0.4 3/4 1250 500 - - - - 277 / 1 1,2,3,4
FPB-3-22 35SST 3 10 700 0.4 1/2 700 200 - - - - 277 / 1 1,2,3,4
FPB-3-23 35SWST 3 8 220 0.4 1/2 220 200 4.7 0.6 55 90 277 / 1 1,2,3
FPB-3-24 35SWST 3 8 220 0.4 1/2 220 200 4.7 0.6 55 90 277 / 1 1,2,3
FPB-3-25 35SWST 3 8 250 0.4 1/2 250 200 3.0 0.4 55 82 277 / 1 1,2,3
FPB-3-26 35SWST 3 8 200 0.4 1/2 200 200 3.1 0.4 55 82 277 / 1 1,2,3
FPB-3-27 35SWST 3 8 220 0.4 1/2 220 200 4.7 0.6 55 90 277 / 1 1,2,3
FPB-3-28 35SWST 3 10 750 0.4 1/2 750 310 10.0 1.4 55 98 277 / 1 1,2,3
FPB-3-29 35SWST 3 8 100 0.4 1/2 100 200 1.2 0.4 55 73 277 / 1 1,2,3
FPB-3-3 35SWST 5 14 1,600 0.4 3/4 1600 975 8.2 1.1 55 76 277 / 1 1,2,3,4
FPB-3-30 35SWST 3 8 310 0.4 1/2 310 200 1.6 0.4 55 75 277 / 1 1,2,3
FPB-3-31 35SWST 3 8 300 0.4 1/2 300 200 1.7 0.4 55 76 277 / 1 1,2,3
FPB-3-32 35SWST 3 8 500 0.4 1/2 500 200 2.8 0.4 55 81 277 / 1 1,2,3
FPB-3-4 35SWST 3 10 700 0.4 1/2 700 555 3.0 0.4 55 73 277 / 1 1,2,3,4
FPB-3-5 35SWST 3 8 500 0.4 1/2 500 260.25 2.8 0.4 55 78 277 / 1 1,2,3
FPB-3-6 35SWST 3 8 500 0.4 1/2 500 260 8.3 1.1 55 97 277 / 1 1,2,3
FPB-3-7 35SWST 3 8 350 0.4 1/2 350 200 3.1 0.4 55 82 277 / 1 1,2,3
FPB-3-8 35SWST 3 8 150 0.4 1/2 150 200 3.4 0.5 55 83 277 / 1 1,2,3,4
FPB-3-9 35SWST 3 8 170 0.4 1/2 170 200 4.2 0.6 55 87 277 / 1 1,2,3
FPB-4-1 35SWST 5 14 1,750 0.4 3/4 1750 1080 8.3 1.1 55 75 277 / 1 1,2,3,4
FPB-4-10 35SWST 3 8 300 0.4 1/2 300 200 3.1 0.4 55 82 277 / 1 1,2,3
FPB-4-11 35SWST 3 8 400 0.4 1/2 400 200 5.9 0.8 55 95 277 / 1 1,2,3
FPB-4-12 35SWST 3 8 300 0.4 1/2 300 200 3.1 0.4 55 82 277 / 1 1,2,3
FPB-4-13 35SWST 3 8 500 0.4 1/2 500 250 8.0 1.1 55 97 277 / 1 1,2,3
FPB-4-14 35SWST 5 14 2,000 0.4 3/4 2000 1125 14.6 2.0 55 80 277 / 1 1,2,3,4
FPB-4-15 35SWST 3 8 300 0.4 1/2 300 200 3.0 0.4 55 82 277 / 1 1,2,3
FPB-4-16 35SWST 3 8 220 0.4 1/2 220 200 4.5 0.6 55 89 277 / 1 1,2,3
FPB-4-17 35SWST 3 8 220 0.4 1/2 220 200 4.5 0.6 55 89 277 / 1 1,2,3
FPB-4-18 35SWST 3 8 220 0.4 1/2 220 200 4.5 0.6 55 89 277 / 1 1,2,3
FPB-4-19 35SWST 3 8 220 0.4 1/2 220 200 4.5 0.6 55 89 277 / 1 1,2,3,4
FPB-4-2 35SWST 3 10 750 0.4 1/2 750 600 3.2 0.4 55 73 277 / 1 1,2,3,4
FPB-4-20 35SWST 5 14 2,000 0.4 3/4 2000 1125 14.6 2.0 55 80 277 / 1 1,2,3,4
FPB-4-21 35SWST 5 14 2,000 0.4 3/4 2000 1125 14.6 2.0 55 80 277 / 1 1,2,3,4
FPB-4-22 35SWST 5 14 2,000 0.4 3/4 2000 1125 14.6 2.0 55 80 277 / 1 1,2,3,4
FPB-4-3 35SST 5 12 1,300 0.4 3/4 1300 500 - - - - 277 / 1 1,2,3,4
FPB-4-4 35SST 3 10 700 0.4 1/2 700 200 - - - - 277 / 1 1,2,3,4
FPB-4-5 35SST 5 12 1,300 0.4 3/4 1300 500 - - - - 277 / 1 1,2,3,4
FPB-4-6 35SST 3 10 700 0.4 1/2 700 200 - - - - 277 / 1 1,2,3,4
FPB-4-7 35SWST 5 14 1,850 0.4 3/4 1850 1335 8.8 1.2 55 74 277 / 1 1,2,3,4
FPB-4-8 35SWST 3 8 450 0.4 1/2 450 250 7.8 1.1 55 97 277 / 1 1,2,3
FPB-4-9 35SWST 3 10 800 0.4 1/2 800 630 3.4 0.5 55 73 277 / 1 1,2,3,4
FPB-5-1 35SWST 5 14 1,750 0.4 3/4 1750 1080 8.3 1.1 55 75 277 / 1 1,2,3,4
FPB-5-10 35SWST 3 8 400 0.4 1/2 400 200 5.4 0.7 55 93 277 / 1 1,2,3
FPB-5-11 35SWST 3 8 300 0.4 1/2 300 200 3.1 0.4 55 82 277 / 1 1,2,3
FPB-5-12 35SWST 3 8 500 0.4 1/2 500 330 10.7 1.5 55 98 277 / 1 1,2,3,4
FPB-5-13 35SWST 5 14 2,000 0.4 3/4 2000 1125 15.8 2.2 55 81 277 / 1 1,2,3
FPB-5-14 35SWST 3 8 300 0.4 1/2 300 200 3.0 0.4 55 82 277 / 1 1,2,3
FPB-5-15 35SWST 5 14 2,000 0.4 3/4 2000 1125 15.8 2.2 55 81 277 / 1 1,2,3,4
FPB-5-16 35SWST 5 14 2,000 0.4 3/4 2000 1125 15.8 2.2 55 81 277 / 1 1,2,3,4
FPB-5-17 35SWST 3 8 250 0.4 1/2 250 200 4.7 0.6 55 90 277 / 1 1,2,3
FPB-5-18 35SWST 3 8 160 0.4 1/2 160 200 3.7 0.5 55 85 277 / 1 1,2,3
FPB-5-19 35SWST 3 8 450 0.4 1/2 450 260 8.3 1.1 55 97 277 / 1 1,2,3
FPB-5-2 35SWST 3 10 750 0.4 1/2 750 600 3.3 0.5 55 73 277 / 1 1,2,3,4
FPB-5-20 35SWST 3 8 220 0.4 1/2 220 200 4.6 0.6 55 89 277 / 1 1,2,3
FPB-5-21 35SWST 3 8 220 0.4 1/2 220 200 4.7 0.6 55 90 277 / 1 1,2,3
FPB-5-22 35SWST 5 14 2,000 0.4 3/4 2000 1125 15.8 2.2 55 81 277 / 1 1,2,3,4
FPB-5-3 35SST 5 12 1,300 0.4 3/4 1300 500 - - - - 277 / 1 1,2,3,4
FPB-5-4 35SST 3 10 700 0.4 1/2 700 200 - - - - 277 / 1 1,2,3,4
FPB-5-5 35SWST 5 14 2,000 0.4 3/4 2000 1275 10.0 1.4 55 75 277 / 1 1,2,3,4
FPB-5-6 35SWST 3 10 900 0.4 1/2 900 690 4.0 0.6 55 73 277 / 1 1,2,3,4
FPB-5-7 35SST 5 12 1,300 0.4 3/4 1300 500 - - - - 277 / 1 1,2,3,4
FPB-5-8 35SST 3 10 700 0.4 1/2 700 200 - - - - 277 / 1 1,2,3,4
FPB-5-9 35SWST 3 8 400 0.4 1/2 400 200 4.1 0.6 55 87 277 / 1 1,2,3
FPB-6-1 35SST 5 12 1,250 0.4 3/4 1250 500 - - - - 277 / 1 1,2,3,4
FPB-6-10 35SWST 3 8 300 0.4 1/2 300 200 3.1 0.4 55 82 277 / 1 1,2,3
FPB-6-11 35SWST 5 14 1,750 0.4 3/4 1750 1080 8.4 1.2 55 75 277 / 1 1,2,3,4
FPB-6-12 35SWST 3 10 800 0.4 1/2 800 600 3.3 0.5 55 73 277 / 1 1,2,3,4
FPB-6-13 35SWST High CFM 16 2,800 0.4 1 2800 1605 19.8 2.7 55 79 277 / 1 1,2,3,4
FPB-6-14 35SST 3 10 700 0.4 1/2 700 200 - - - - 277 / 1 1,2,3,4
FPB-6-15 35SST 5 12 1,250 0.4 3/4 1250 500 - - - - 277 / 1 1,2,3,4
FPB-6-16 35SWST 3 8 250 0.4 1/2 250 200 4.5 0.6 55 89 277 / 1 1,2,3
FPB-6-17 35SWST 3 8 150 0.4 1/2 150 200 3.5 0.5 55 84 277 / 1 1,2,3
FPB-6-18 35SWST 3 8 220 0.4 1/2 220 200 4.5 0.6 55 89 277 / 1 1,2,3
FPB-6-19 35SWST 3 8 220 0.4 1/2 220 200 4.4 0.6 55 88 277 / 1 1,2,3
FPB-6-2 35SST 3 10 700 0.4 1/2 700 200 - - - - 277 / 1 1,2,3,4
FPB-6-20 35SWST High CFM 16 2,650 0.4 1 2650 1455 19.2 2.7 55 80 277 / 1 1,2,3,4
FPB-6-21 35SWST 3 10 850 0.4 1/2 850 660 4.0 0.6 55 73 277 / 1 1,2,3,4
FPB-6-3 35SWST 3 8 450 0.4 1/2 450 250 8.0 1.1 55 97 277 / 1 1,2,3
FPB-6-4 35SWST 5 14 1,750 0.4 3/4 1750 1290 8.3 1.1 55 74 277 / 1 1,2,3,4
FPB-6-5 35SWST 3 8 370 0.4 1/2 370 200 4.1 0.6 55 87 277 / 1 1,2,3
FPB-6-6 35SWST 3 8 400 0.4 1/2 400 200 5.9 0.8 55 95 277 / 1 1,2,3
FPB-6-7 35SWST 3 8 300 0.4 1/2 300 200 3.2 0.4 55 83 277 / 1 1,2,3
FPB-6-8 35SWST 3 8 500 0.4 1/2 500 250 8.0 1.1 55 97 277 / 1 1,2,3
FPB-6-9 35SWST High CFM 16 3,100 0.4 1 3100 1455 23.7 3.3 55 83 277 / 1 1,2,3
FPB-7-1 35SWST 3 8 400 0.4 1/2 400 200 4.2 0.6 55 87 277 / 1 1,2,3
FPB-7-10 35SWST 3 8 400 0.4 1/2 400 200 6.4 0.9 55 97 277 / 1 1,2,3
FPB-7-11 35SWST 3 8 150 0.4 1/2 150 200 3.7 0.5 55 85 277 / 1 1,2,3
FPB-7-12 35SWST 3 8 150 0.4 1/2 150 200 3.5 0.5 55 84 277 / 1 1,2,3
FPB-7-13 35SWST 3 8 160 0.4 1/2 160 200 2.4 0.4 55 79 277 / 1 1,2,3
FPB-7-14 35SWST 3 8 400 0.4 1/2 400 200 6.1 0.8 55 96 277 / 1 1,2,3
FPB-7-15 35SWST 3 8 400 0.4 1/2 400 200 4.2 0.6 55 87 277 / 1 1,2,3
FPB-7-16 35SWST 3 8 250 0.4 1/2 250 200 3.3 0.5 55 83 277 / 1 1,2,3
FPB-7-17 35SWST 3 8 200 0.4 1/2 200 200 3.7 0.5 55 85 277 / 1 1,2,3
FPB-7-18 35SWST 3 8 400 0.4 1/2 400 200 4.2 0.6 55 87 277 / 1 1,2,3
FPB-7-19 35SWST 3 8 100 0.4 1/2 100 200 1.4 0.4 55 74 277 / 1 1,2,3
FPB-7-2 35SWST 3 8 300 0.4 1/2 300 200 3.5 0.5 55 84 277 / 1 1,2,3,4
FPB-7-20 35SWST 3 8 150 0.4 1/2 150 200 1.9 0.4 55 77 277 / 1 1,2,3,4
FPB-7-21 35SWST 3 8 150 0.4 1/2 150 200 1.9 0.4 55 77 277 / 1 1,2,3,4
FPB-7-3 35SWST 5 14 1,700 0.4 3/4 1700 1365 11.4 1.6 55 75 277 / 1 1,2,3
FPB-7-4 35SWST 3 10 800 0.4 1/2 800 260 8.2 1.1 55 97 277 / 1 1,2,3
FPB-7-5 35SWST 3 8 120 0.4 1/2 120 200 1.6 0.4 55 75 277 / 1 1,2,3
FPB-7-6 35SWST 3 8 400 0.4 1/2 400 200 4.2 0.6 55 87 277 / 1 1,2,3
FPB-7-7 35SWST 3 8 400 0.4 1/2 400 200 5.3 0.7 55 92 277 / 1 1,2,3
FPB-7-8 35SWST 3 8 450 0.4 1/2 450 200 6.1 0.8 55 96 277 / 1 1,2,3
FPB-7-9 35SWST 3 8 150 0.4 1/2 150 200 2.4 0.4 55 79 277 / 1 1,2,3
FPB-8-1 35SWST 3 8 500 0.4 1/2 500 210 4.4 0.6 55 87 277 / 1 1,2,3,4
FPB-8-10 35SWST 3 8 450 0.4 1/2 450 240 6.3 0.9 55 92 277 / 1 1,2,3,4
FPB-8-11 35SWST 3 8 320 0.4 1/2 320 200 6.5 0.9 55 98 277 / 1 1,2,3
FPB-8-12 35SST 3 8 120 0.4 1/2 120 200 - - - - 277 / 1 1,2,3,4
FPB-8-13 35SWST 3 8 600 0.4 1/2 600 350 11.3 1.6 55 98 277 / 1 1,2,3
FPB-8-14 35SWST 3 8 400 0.4 1/2 400 200 4.7 0.6 55 90 277 / 1 1,2,3
FPB-8-15 35SWST 3 10 900 0.4 1/2 900 300 9.7 1.3 55 98 277 / 1 1,2,3
FPB-8-16 35SWST 3 8 650 0.4 1/2 650 310 9.8 1.4 55 97 277 / 1 1,2,3
FPB-8-17 35SWST 3 8 500 0.4 1/2 500 300 2.6 0.4 55 76 277 / 1 1,2,3,4
FPB-8-18 35SWST 3 8 600 0.4 1/2 600 300 9.4 1.3 55 97 277 / 1 1,2,3
FPB-8-2 35SWST 5 12 1,200 0.4 3/4 1200 500 11.6 1.6 55 89 277 / 1 1,2,3
FPB-8-3 35SWST 3 8 550 0.4 1/2 550 200 5.6 0.8 55 94 277 / 1 1,2,3
FPB-8-4 35SWST 3 8 350 0.4 1/2 350 200 5.7 0.8 55 94 277 / 1 1,2,3
FPB-8-5 35SWST 3 8 350 0.4 1/2 350 200 3.7 0.5 55 85 277 / 1 1,2,3
FPB-8-6 35SWST 3 8 500 0.4 1/2 500 200 4.9 0.7 55 90 277 / 1 1,2,3
FPB-8-7 35SWST 3 8 100 0.4 1/2 100 200 0.8 0.4 55 71 277 / 1 1,2,3,4
FPB-8-8 35SWST 3 8 120 0.4 1/2 120 200 2.6 0.4 55 80 277 / 1 1,2,3
FPB-8-9 35SWST 3 8 300 0.4 1/2 300 200 5.4 0.7 55 93 277 / 1 1,2,3,4
NOTES:1. HEATING COIL SELECTION BASED ON 2 ROW SELECTION WITH 140°F EWT, 120°F LWT.2. ALL SUPPLY DUCTS TO VAV BOXES SHALL BE MATCHED TO THE VAV BOX INLET SIZE UON.3. PROVIDE WITH ECM MOTOR.4. PROVIDE WITH CO2 SENSING FOR DEMAND CONTORL VENTILATION
FAN POWERED TERMINAL WITH HOT WATER COIL (CONTINUED)
DESIGNATION NAILOR MODELNUMBER UNIT INLET DUCT
SIZE (INCHES)
FAN PRIMARYCFM HEATING COIL
VOLTAGE/PHASE NOTES
CFM
ESP
(IN.
WG
)
HP
MAX
IMU
M
MIN
IMU
M
CAP
ACIT
Y (M
BH)
GPM EA
T(°
F)
LAT
(°F)
FAN POWERED TERMINAL WITH HOT WATER COIL (CONTINUED)
DESIGNATION NAILOR MODELNUMBER UNIT INLET DUCT
SIZE (INCHES)
FAN PRIMARYCFM HEATING COIL
VOLTAGE/PHASE NOTES
CFM
ESP
(IN.
WG
)
HP
MAX
IMU
M
MIN
IMU
M
CAP
ACIT
Y (M
BH)
GPM EA
T(°
F)
LAT
(°F)
VAV TERMINAL UNIT SCHEDULE
DESIGNATION LOCATION BASIS OFDESIGN
CFM SETTING
UNIT INLET DESIGN Min Vent Box Min NOTES
SIZE SIZE MAX CFM CFM CFM
VAV 0-1 005 CORR TITUS DESV 4 4 210 63 45 1
VAV 0-2 014 CELL TITUS DESV 4 4 160 48 45 1
VAV 0-3 013 CELL TITUS DESV 6 6 380 114 80 1
VAV 0-4 015 MTG TITUS DESV 4 4 80 24 45 1
VAV 0-5 016 BOH TITUS DESV 4 4 120 36 45 1
VAV 0-6 020 CORR TITUS DESV 8 8 700 210 145 1
VAV 0-7 001 BOH TITUS DESV 6 6 420 126 80 1
VAV 0-8 012 CELL TITUS DESV 8 8 660 198 145 1
VAV 0-9 019 CORR TITUS DESV 6 6 400 120 80 1
VAV 0-10 018 BOH TITUS DESV 4 4 100 30 45 1
VAV 0-11 017 CELL TITUS DESV 4 4 110 33 45 1
VAV 0-12 SECURITY VEST TITUS DESV 4 4 100 30 45 1
VAV 0-13 EVID STOR TITUS DESV 4 4 150 45 45 2
VAV 1-1 115 CELL/BOH TITUS DESV 6 6 400 120 80 1
VAV 1-2 100 CORR W TITUS DESV 4 4 200 60 45 1
VAV 1-3 112 ATTY TITUS DESV 6 6 350 105 80 1
VAV 1-4 112 ATTY E TITUS DESV 6 6 250 75 80 1
VAV 1-5 100 CORR TITUS DESV 4 4 200 60 45 1
VAV 1-6 162 LOCKERS TITUS DESV 4 4 80 24 45 1
VAV 1-7 100 CORR E TITUS DESV 6 6 350 105 80 1
VAV 1-8 125 BOH TITUS DESV 4 4 170 51 45 1
VAV 1-9 122 ATTY TITUS DESV 4 4 70 21 45 1
VAV 1-10 170 OPEN OFFICE TITUS DESV 6 6 500 150 80 1
VAV 1-11 172 PUBLIC LOBBY TITUS DESV 8 8 600 180 145 1
VAV 1-12 105 OFFICE TITUS DESV 4 4 210 63 45 1
VAV 1-13 106 BOH TITUS DESV 4 4 50 15 45 1
VAV 1-14 165 JURY CHECK-IN TITUS DESV 6 6 500 150 80 1, 3
VAV 1-15 166 JURY WAIT TITUS DESV 6 6 250 75 80 1, 3
VAV 1-16 107 PUBLIC LOBBY TITUS DESV 10 10 1,400 420 230 1
VAV 1-17 137 BOH TITUS DESV 6 6 320 96 80 1
VAV 1-18 150 OPEN OFFICE TITUS DESV 6 6 300 90 80 1
VAV 1-19 151 OPEN OFFICE TITUS DESV 6 6 300 90 80 1
VAV 2-1 222 BOH TITUS DESV 6 6 400 120 80 1
VAV 2-2 269 CORRIDOR TITUS DESV 4 4 180 54 45 1
VAV 2-3 217 OFFICE TITUS DESV 8 8 650 195 145 1
VAV 2-4 261 WAIT TITUS DESV 8 8 700 210 145 1, 3
VAV 2-5 270 CORRIDOR TITUS DESV 4 4 150 45 45 1
VAV 2-6 265 OPEN OFFICE TITUS DESV 6 6 250 75 80 1
VAV 2-7 260 OFFICE TITUS DESV 4 4 120 36 45 1
VAV 2-8 218 STOR TITUS DESV 4 4 50 15 45 1
VAV 2-9 259 HD STOR TITUS DESV 4 4 130 39 45 1
VAV 2-10 210 HD STOR TITUS DESV 4 4 160 48 45 1
VAV 2-11 255 WAIT TITUS DESV 6 6 250 75 80 1, 3
VAV 2-12 254 OPEN OFFICE TITUS DESV 6 6 250 75 80 1
VAV 2-13 212 OPEN OFFICE TITUS DESV 6 6 300 90 80 1
VAV 2-14 256 CORRIDOR TITUS DESV 6 6 370 111 80 1
VAV 2-15 213 STOR TITUS DESV 4 4 100 30 45 1
VAV 2-16 214 CONF TITUS DESV 4 4 80 24 45 1
VAV 2-17 253 OPEN OFFICE TITUS DESV 6 6 310 93 80 1
VAV 2-18 250 CONF TITUS DESV 4 4 80 24 45 1, 3
VAV 2-19 224 WAIT TITUS DESV 8 8 800 240 145 1, 3
VAV 2-20 262 OFFICE TITUS DESV 4 4 160 48 45 1
VAV 2-21 209 OPEN OFFICE TITUS DESV 6 6 500 150 80 1
VAV 2-22 273 OPEN OFFICE TITUS DESV 4 4 110 33 45 1
VAV 3-1 321 CORRIDOR TITUS DESV 6 6 360 108 80 1
VAV 3-2 369 OPEN OFFICE TITUS DESV 6 6 400 120 80 1
VAV 3-3 ATTY WEST TITUS DESV 4 4 100 30 45 2
VAV 3-4 323 CELL/BOH TITUS DESV 8 8 620 186 145 1
VAV 3-5 339 ATTY TITUS DESV 4 4 170 51 45 1
VAV 3-6 319 WAIT TITUS DESV 14 14 2,800 840 450 1
VAV 3-7 320 ATTY E TITUS DESV 4 4 150 45 45 1
VAV 3-8 320 ATTY W TITUS DESV 4 4 150 45 45 1
VAV 3-10 316 CELL/BOH TITUS DESV 6 6 420 126 80 1
VAV 4-1 408 CELL/BOH TITUS DESV 6 6 410 123 80 1
VAV 4-2 414 CORR/BOH TITUS DESV 6 6 380 114 80 1
VAV 4-3 459 CORR/BOH TITUS DESV 6 6 400 120 80 1
VAV 4-4 413 CELL/BOH TITUS DESV 6 6 400 120 80 1
VAV 4-5 463 ATTY TITUS DESV 4 4 100 30 45 1
VAV 4-6 461 ATTY TITUS DESV 4 4 140 42 45 1
VAV 4-7 411 ATTY TITUS DESV 4 4 140 42 45 1
VAV 4-8 464 ATTY TITUS DESV 4 4 100 30 45 1
VAV 5-1 508 CELL/BOH TITUS DESV 6 6 410 123 80 1
VAV 5-2 523 CORRIDOR W TITUS DESV 6 6 380 114 80 1
VAV 5-3 506 OPEN OFFICE TITUS DESV 6 6 270 81 80 1
VAV 5-4 504 OPEN OFFICE TITUS DESV 6 6 360 108 80 1
VAV 5-5 513 CELL/BOH TITUS DESV 6 6 400 120 80 1
VAV 5-6 554 CORRIDOR TITUS DESV 6 6 430 129 80 1
VAV 5-7 502B ATTY TITUS DESV 4 4 100 30 45 1
VAV 5-8 552 ATTY TITUS DESV 4 4 140 42 45 1
VAV 5-9 511 ATTY TITUS DESV 4 4 140 42 45 1
VAV 5-10 551 ATTY TITUS DESV 4 4 100 30 45 1
VAV 6-1 623 CORR/BOH TITUS DESV 6 6 400 120 80 1
VAV 6-2 605 OPEN OFFICE TITUS DESV 6 6 280 84 80 1
VAV 6-3 603 OPEN OFFICE TITUS DESV 6 6 370 111 80 1
VAV 6-4 655 CORR/BOH TITUS DESV 6 6 430 129 80 1
VAV 6-5 612 CELL/BOH TITUS DESV 6 6 400 120 80 1
VAV 6-6 662 ATTY TITUS DESV 4 4 100 30 45 1
VAV 6-7 652 ATTY TITUS DESV 4 4 140 42 45 1
VAV 6-8 610 ATTY TITUS DESV 4 4 140 42 45 1
VAV 6-9 675 ATTY TITUS DESV 4 4 100 30 45 1
VAV 6-10 607 CELL/BOH TITUS DESV 6 6 410 123 80 1
VAV 7-1 726 OPEN OFFICE TITUS DESV 4 4 200 60 45 1
VAV 7-2 738 OFFICE TITUS DESV 4 4 200 60 45 1
VAV 7-3 720 OPEN OFFICE TITUS DESV 6 6 300 90 80 1
VAV 7-4 735 OFFICE TITUS DESV 4 4 200 60 45 1
VAV 7-5 747 CORRIDOR TITUS DESV 6 6 250 75 80 1
VAV 7-6 727 OFFICE TITUS DESV 6 6 260 78 80 1
VAV 7-7 734 OFFICE TITUS DESV 6 6 330 99 80 1
VAV 7-8 712 STOR TITUS DESV 4 4 120 36 45 1
VAV 7-9 733 OPEN OFFICE TITUS DESV 6 6 300 90 80 1
VAV 7-10 732 OFFICE TITUS DESV 4 4 170 51 45 1
VAV 7-11 735 OFFICE TITUS DESV 6 6 300 90 80 1
VAV 7-12 737 OPEN OFFICE TITUS DESV 6 6 260 78 80 1
VAV 7-13 739 OFFICE TITUS DESV 6 6 310 93 80 1
VAV 7-14 741 OFFICE TITUS DESV 4 4 200 60 45 1
VAV 7-15 743 OFFICE TITUS DESV 4 4 160 48 45 1
VAV 7-16 742 OPEN OFFICE TITUS DESV 6 6 370 111 80 1
VAV 7-17 744 OFFICE TITUS DESV 4 4 160 48 45 1
VAV 8-1 880 OPEN OFFICE TITUS DESV 6 6 260 78 80 1, 2
VAV 8-2 877 OFFICE TITUS DESV 4 4 210 63 45 1, 2
VAV 8-3 864 OFFICE TITUS DESV 4 4 140 42 45 1, 2
VAV 8-4 876 OFFICE TITUS DESV 6 6 260 78 80 1, 2
VAV 8-5 875 OPEN OFFICE TITUS DESV 8 8 650 195 145 1, 2
VAV 8-6 865 OFFICE TITUS DESV 4 4 140 42 45 1, 2
VAV 8-7 868 STOR TITUS DESV 4 4 160 48 45 1, 2
VAV 8-8 870 OFFICE TITUS DESV 6 6 240 72 80 1, 2
VAV 8-9 852 OFFICE TITUS DESV 6 6 240 72 80 1, 2
VAV 8-10 874 STOR TITUS DESV 4 4 70 21 45 1, 2
VAV 8-11 873 OPEN OFFICE TITUS DESV 6 6 380 114 80 1, 2
VAV 8-12 878 OFFICE TITUS DESV 6 6 250 75 80 1, 2
VAV 8-13 878 BOH TITUS DESV 6 6 250 75 80 1, 2
VAV 8-14 881 BOH TITUS DESV 6 6 250 75 80 1, 2
GENERAL NOTES: HOT WATER COILS SELECTED WITH EWT - 140F, LWT - 120F.
NUMBERED NOTES:
1. PROVIDE VAV WITH 1" ECOSHIELD LINER2. PROVIDE WITH HW COIL3 PROVIDE WITH CO2 SENSING FOR DEMAND CONTORL VENTILATION
VAV TERMINAL UNIT SCHEDULE (CONTINUED)
DESIGNATION LOCATION BASIS OFDESIGN
CFM SETTING
UNIT INLET DESIGN Min Vent Box Min NOTES
SIZE SIZE MAX CFM CFM CFM
VAV TERMINAL UNIT SCHEDULE (CONTINUED)
DESIGNATION LOCATION BASIS OFDESIGN
CFM SETTING
UNIT INLET DESIGN Min Vent Box Min NOTES
SIZE SIZE MAX CFM CFM CFM
VAV TERMINAL UNIT SCHEDULE (CONTINUED)
DESIGNATION LOCATION BASIS OFDESIGN
CFM SETTING
UNIT INLET DESIGN Min Vent Box Min NOTES
SIZE SIZE MAX CFM CFM CFM
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:1
6 P
M
05.22.2015
1309100
M-602
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALSCHEDULES
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
AIR INLET AND OUTLET SCHEDULE
DESIGNATION MANUFACTURERMODEL NUMBER SERVICE FACE
DIMENSIONS COLOR BORDER REMARKS
LD-A TITUS FL-10 HIGHTHROW SUPPLY 2 SLOT, SEE PLANS WHITE 2
LD-B TITUS FL-10 JET THROW SUPPLY 2 SLOT, SEE PLANS WHITE 2
CD-A TITUS TMS SUPPLY 24"x24" WHITE
CD-B TITUS SG-LFF SECURITY SUPPLY SEE PLANS WHITE
SG-A TITUS 300-FL SIDEWALL SUPPLY SEE PLANS WHITE
RG-A TITUS PAR RETURN 24"x24" WHITE
RG-B TITUS FL-10 JET THROW RETURN SEE PLANS WHITE 2
EG-A TITUS 3FL EXHAUST SEE PLANS WHITE
EG-B TITUS SG-LFF SECURITY EXHAUST SEE PLANS WHITE
EG-C TITUS 8F EXHAUST 24"x24" WHITEGENERAL NOTES:A) BAKED ENAMEL FINISH UNLESS OTHERWISE NOTED.
NUMBERED NOTES:1) PROVIDE INTEGRAL OPPOSED BLADE DAMPER FOR BALANCING.2) PROVIDE WITH TITUS SERIES MPI INSULATED PLENUM.
ELECTRIC UNIT HEATER SCHEDULE
DESIGNATION SERVICE /LOCATION
MANUF.MODEL
NUMBERAIRFLOW
(CFM)
HEATINGTOTAL
AMPERAGEVOLTAGE/
PHASE NOTES
KW EAT
(°F)
LAT
(°F)
UH-B-1 WATER ENTRY INDEECO WAI 160 3.0 40 100 14.8 208 / 1 NOTE 1
UH-B-2 FIRE COMMAND INDEECO WAI 160 3.0 40 100 14.8 208 / 1 NOTE 1
UH-B-3 FIRE PUMP INDEECO WAI 160 3.0 40 100 14.8 208 / 1 NOTE 1
UH-1-1 STAIR SW INDEECO WAI 320 6.0 40 100 29.2 208 / 1 NOTE 1
UH-1-2 STAIR SE INDEECO WAI 320 6.0 40 100 29.2 208 / 1 NOTE 1GENERAL NOTES:A) COORDINATE COLOR AND FINISH WITH ARCHITECTB) PROVIDE ALL UNIT HEATERS WITH INTEGRAL DISCONNECT.
NUMBERED NOTES:1) UNIT SHALL BE SEMI-RECESSED. PROVIDE ALL REQUIRED TRIM KITS.2) PROVIDE INTEGRAL TAMPERPROOF THERMOSTAT.3) UNIT SHALL BE SURFACE MOUNTED. PROVIDE ALL REQUIRED TRIM KITS.
AIR COOLED CONDENSER OUTDOOR UNIT SCHEDULE
DESIGNATION LOCATION / SERVICEMANUF.MODEL
NUMBERREF
COOLINGCAPACITY
(MBH)
HEATINGCAPACITY
(MBH)EER IEER
ELECTRICAL
WEIGHT(LBS) NOTES
MC
A (A
)
VOLT
AGE
/PH
ASE
HP-R-1 ROOF / 24/7 COOLING MITSUBISHIPUHY-P240YSKMU R-410A 240.0 -- 12.1 18.6 40 460 / 3 1500
HP-R-2 ROOF / 24/7 COOLING MITSUBISHIPUHY-P240YSKMU R-410A 240.0 -- 12.1 18.6 40 460 / 3 1500
HP-R-3 ROOF / 24/7 COOLING MITSUBISHIPUHY-P240YSKMU R-410A 240.0 -- 12.1 18.6 40 460 / 3 1500
HP-R-4 ROOF / 24/7 COOLING MITSUBISHIPUHY-P240YSKMU R-410A 240.0 -- 12.1 18.6 40 208 / 1 287
HP-B-5 BASEMENT LOADING DOCK / 24/7 COOLING MITSUBISHIPUMY-P60NKMU R-410A 60.0 -- 10.0 -- 35
GENERAL NOTES:A) DISCONNECTS BY DIV 26B) EFFICIENCY LISTED AT RATED CONDITIONSNUMBERED NOTES:1. BACK-UP HEAT PUMP FOR 24/7 COOLING IN BASEMENT CONTORL ROOM. PROVIDE WITH EMERGENCY POWER.
FAN SCHEDULE
DESIGNATIONMANUF.MODEL
NUMBERLOCATION/SERVICE TYPE CFM
STATICPRESSURE
(IN. WG.)RPM BHP
MOTOR
STANDBYPOWER
OPERATINGWEIGHT
(LBS)
VAR.SPEED(Y/N)
NOTES
HP
(WAT
TS)
VOLT
AGE/
PHAS
E
SPF-R-1 COOK 180QMXS STAIR PRESSURIZATION ROOFTOP UTILTY SET FAN 8000 2.5 2083 5.24 7.5 460/3 Y 900 Y
SPF-R-2 COOK 180QMXS STAIR PRESSURIZATION ROOFTOP UTILTY SET FAN 8000 2.5 2083 5.24 7.5 460/3 Y 900 Y
SPF-R-3 COOK 180QMXS STAIR PRESSURIZATION ROOFTOP UTILTY SET FAN 8000 2.5 2083 5.24 7.5 460/3 Y 900 Y
SPF-R-4 COOK 180QMXS STAIR PRESSURIZATION ROOFTOP UTILTY SET FAN 8000 2.5 2083 5.24 7.5 460/3 Y 900 Y
HPF-R-1 COOK 225QMXS HOISTWAY PRESSURIZATION ROOFTOP UTILTY SET FAN 10000 2.5 1481 6.13 7.5 460/3 Y 1200 Y
HPF-R-2 COOK 225QMXS HOISTWAY PRESSURIZATION ROOFTOP UTILTY SET FAN 10000 2.5 1481 6.13 7.5 460/3 Y 1200 Y
HPF-R-3 COOK 225QMXS HOISTWAY PRESSURIZATION ROOFTOP UTILTY SET FAN 10000 2.5 1481 6.13 7.5 460/3 Y 1200 Y
HPF-R-4 COOK 300QMXS HOISTWAY PRESSURIZATION ROOFTOP UTILTY SET FAN 20000 2.5 1200 12 20.0 460/3 Y 2000 Y
HPF-R-5 COOK 300QMXS HOISTWAY PRESSURIZATION ROOFTOP UTILTY SET FAN 20000 2.5 1200 12 20.0 460/3 Y 2000 Y
PRF-R-1 COOK 490QMXU PRESSURIZATION RELIEF ROOFTOP UTILTY SET FAN 51000 2.5 717 30 50.0 460/3 Y 5500 Y
EF-B-1 COOK 330-SQN-B LOADING DOCK EXHAUST CENTRIFUGAL INLINE 15000 0.75 741 5.2 7.5 460/3 N 650 N 2
EF-B-2 COOK 165-SQN10D LOADING DOCK EXHAUST CENTRIFUGAL INLINE 2000 0.25 907 0.23 0.5 115/1 N 200 N 2
EF-B-3 COOK 165-SQN10D SALLY PORT EXHAUST CENTRIFUGAL INLINE 2400 0.25 805 0.11 0.33 115/1 N 180 N 2
EF-B-4 COOK 150-SQN10D RECEIVING EXHAUST CENTRIFUGAL INLINE 1600 0.25 966 0.19 0.33 115/1 N 180 N 2
EF-B-5 COOK 90-SQN12D RECYCLING EXHAUST CENTRIFUGAL INLINE 400 0.2 1370 0.15 0.17 115/1 N 100 N 2
EF-1-1 COOK SQ-100-VG L-1 EAST - TSER TRANSFER FAN CENTRIFUGAL INLINE 800 0.25 1157 0.07 0.25 115/1 N 55 N 4
EF-1-2 COOK SQ-100-VG L-1 WEST AV ROOM CENTRIFUGAL INLINE 500 0.25 1157 0.07 0.25 115/1 N 55 N 4
EF-1-3 COOK SQ-100-VG L-1 SOUTH AV ROOM CENTRIFUGAL INLINE 500 0.25 1157 0.07 0.25 115/1 N 56 N 4
EF-2-7 COOK SQ-100-VG L-2 EAST - ELEC TRANSFER FAN CENTRIFUGAL INLINE 800 0.25 1157 0.07 0.25 115/1 N 55 N 4
EF-3-1 COOK SQ-100-VG L-3 WEST - ELEC TRANSFER FAN CENTRIFUGAL INLINE 800 0.25 1157 0.07 0.25 115/1 N 55 N 4
EF-3-2 COOK SQ-100-VG L-3 WEST AV ROOM CENTRIFUGAL INLINE 500 0.25 1157 0.07 0.25 115/1 N 55 N 4
EF-3-3 COOK SQ-100-VG L-3 EAST AV ROOM CENTRIFUGAL INLINE 500 0.25 1157 0.07 0.25 115/1 N 55 N 4
EF-4-1 COOK SQ-120-VG L-4 WEST - ELEC TRANSFER FAN CENTRIFUGAL INLINE 1200 0.25 1071 0.11 0.50 115/1 N 65 N 4
EF-4-2 COOK SQ-100-VG L-4 WEST AV ROOM CENTRIFUGAL INLINE 500 0.25 1157 0.07 0.25 115/1 N 55 N 4
EF-4-3 COOK SQ-100-VG L-4 EAST AV ROOM CENTRIFUGAL INLINE 500 0.25 1157 0.07 0.25 115/1 N 55 N 4
EF-5-1 COOK SQ-120-VG L-5 WEST - ELEC TRANSFER FAN CENTRIFUGAL INLINE 1200 0.25 1071 0.11 0.50 115/1 N 65 N 4
EF-5-2 COOK SQ-100-VG L-5 WEST AV ROOM CENTRIFUGAL INLINE 500 0.25 1157 0.07 0.25 115/1 N 55 N 4
EF-5-3 COOK SQ-100-VG L-5 EAST AV ROOM CENTRIFUGAL INLINE 500 0.25 1157 0.07 0.25 115/1 N 55 N 4
EF-6-1 COOK SQ-140-VG L-6 WEST - ELEC TRANSFER FAN CENTRIFUGAL INLINE 1200 0.25 1071 0.11 0.50 115/1 N 65 N 4
EF-6-2 COOK SQ-100-VG L-6 WEST AV ROOM CENTRIFUGAL INLINE 500 0.25 1157 0.07 0.25 115/1 N 55 N 4
EF-6-3 COOK SQ-100-VG L-6 EAST AV ROOM CENTRIFUGAL INLINE 500 0.25 1157 0.07 0.25 115/1 N 55 N 4
EF-7-1 COOK SQ-100-VG L-7 EAST - ELEC TRANSFER FAN CENTRIFUGAL INLINE 1800 0.25 1075 0.24 0.75 115/1 N 90 N 4
EF-R-1 COOK SQ-100-VG ROOF WEST - ELEC TRANSFER FAN CENTRIFUGAL INLINE 800 0.25 1157 0.07 0.25 115/1 N 55 N 4
SF-B-1 COOK 150SQN-B TRANSFORMER SUPPLY CENTRIFUGAL INLINE 4000 0.5 1935 1.73 2.0 460/3 N 215 N 1, 3
SF-B-2 COOK 150SQN-B TRANSFORMER SUPPLY CENTRIFUGAL INLINE 4000 0.5 1935 1.73 2.0 460/3 N 215 N 1, 3GENERAL NOTES:A. COORDINATE LOCATION AND MOUNTING HEIGHT WITH ARCHITECT.B. PROVIDE WITH ECM MOTOR OR MOTOR EFFICIENCY OF 70% OR GREATER ON ALL MOTORS 1 HP AND BELOW. PROVIDE WITH FAN SPEED CONTROLLER.
NUMBERED NOTES:1) CONTROLLED BY TRANSFORMER VAULT ROOM TEMPERATURE.2) PROVIDE WITH OUTLET BACKDRAFT DAMPER TO PREVENT REVERSE AIRFLOW.3) PROVIDE WITH INTEGRAL MOTORIZED DAMPER WITH SINGLE POINT WIRING CONNECTION AND END SWITCH CONTROL.4) PROVIDE WITH LINE VOLTAGE THERMOSTAT
FIRE SMOKE DAMPER SCHEDULE
DESIGNATION LOCATION ASSOCIATEDSYSTEM
DIMENSIONS
ORIENTATION NOTES
WID
TH
HEI
GH
T
FSD-B-1 LEVEL B EXHAUST 26 18 HORIZONTAL
FSD-B-2 LEVEL B WEST SHAFT SUPPLY 18 14 HORIZONTAL
FSD-1-1 LEVEL 1 EXHAUST EXHAUST 26 16 HORIZONTAL
FSD-1-2 LEVEL 1 EXHAUST EXHAUST 16 14 HORIZONTAL
FSD-1-3 LEVEL 1 EAST SHAFT SUPPLY 16 12 HORIZONTAL
FSD-1-4 LEVEL 1 EAST SHAFT SUPPLY 32 18 HORIZONTAL
FSD-1-5 LEVEL 1 WEST SHAFT SUPPLY 34 20 HORIZONTAL
FSD-1-6 LEVEL 1 WEST SHAFT SUPPLY 26 18 HORIZONTAL
FSD-1-7 LEVEL 1 WEST SHAFT RETURN 40 22 HORIZONTAL
FSD-1-8 LEVEL 1 EAST SHAFT RETURN 40 22 HORIZONTAL
FSD-2-1 LEVEL 2 EXHAUST EXHAUST 16 8 HORIZONTAL
FSD-2-2 LEVEL 2 EXHAUST EXHAUST 12 12 HORIZONTAL
FSD-2-3 LEVEL 2 EAST SHAFT RETURN 40 20 HORIZONTAL
FSD-2-4 LEVEL 2 EAST SHAFT SUPPLY 40 20 HORIZONTAL
FSD-2-5 LEVEL 2 WEST SHAFT RETURN 36 20 HORIZONTAL
FSD-2-6 LEVEL 2 WEST SHAFT SUPPLY 36 20 HORIZONTAL
FSD-3-1 LEVEL 3 EXHAUST EXHAUST 26 16 HORIZONTAL
FSD-3-2 LEVEL 3 EXHAUST EXHAUST 12 12 HORIZONTAL
FSD-3-3 LEVEL 3 EAST RETURN 46 34 HORIZONTAL
FSD-3-4 LEVEL 3 EAST SUPPLY 30 18 HORIZONTAL
FSD-3-5 LEVEL 3 EAST SUPPLY 40 26 HORIZONTAL
FSD-3-6 LEVEL 3 WEST RETURN 44 26 HORIZONTAL
FSD-3-7 LEVEL 3 WEST SUPPLY 30 18 HORIZONTAL
FSD-3-8 LEVEL 3 WEST SUPPLY 40 30 HORIZONTAL
FSD-4-1 LEVEL 4 EXHAUST EXHAUST 26 16 HORIZONTAL
FSD-4-2 LEVEL 4 EXHAUST EXHAUST 20 14 HORIZONTAL
FSD-4-3 LEVEL 4 EAST RETURN 44 26 HORIZONTAL
FSD-4-4 LEVEL 4 EAST SUPPLY 30 20 HORIZONTAL
FSD-4-5 LEVEL 4 EAST SUPPLY 32 16 HORIZONTAL
FSD-4-6 LEVEL 4 WEST RETURN 44 26 HORIZONTAL
FSD-4-7 LEVEL 4 WEST SUPPLY 26 18 HORIZONTAL
FSD-4-8 LEVEL 4 WEST SUPPLY 36 20 HORIZONTAL
FSD-5-1 LEVEL 5 EXHAUST EXHAUST 26 16 HORIZONTAL
FSD-5-2 LEVEL 5 EXHAUST EXHAUST 20 14 HORIZONTAL
FSD-5-3 LEVEL 5 EAST RETURN 44 26 HORIZONTAL
FSD-5-4 LEVEL 5 EAST SUPPLY 30 20 HORIZONTAL
FSD-5-5 LEVEL 5 EAST SUPPLY 32 16 HORIZONTAL
FSD-5-6 LEVEL 5 WEST RETURN 44 26 HORIZONTAL
FSD-5-7 LEVEL 5 WEST SUPPLY 26 18 HORIZONTAL
FSD-5-8 LEVEL 5 WEST SUPPLY 36 20 HORIZONTAL
FSD-6-1 LEVEL 6 EXHAUST EXHAUST 26 16 HORIZONTAL
FSD-6-2 LEVEL 6 EXHAUST EXHAUST 20 14 HORIZONTAL
FSD-6-3 LEVEL 6 EAST RETURN 44 26 HORIZONTAL
FSD-6-4 LEVEL 6 EAST SUPPLY 30 20 HORIZONTAL
FSD-6-5 LEVEL 6 EAST SUPPLY 32 16 HORIZONTAL
FSD-6-6 LEVEL 6 WEST RETURN 44 26 HORIZONTAL
FSD-6-7 LEVEL 6 WEST SUPPLY 26 18 HORIZONTAL
FSD-6-8 LEVEL 6 WEST SUPPLY 36 20 HORIZONTAL
FSD-7-1 LEVEL 7 EXHAUST EXHAUST 26 16 HORIZONTAL
FSD-7-2 LEVEL 7 EAST SUPPLY 22 14 HORIZONTAL
FSD-7-3 LEVEL 7 EAST RETURN 40 20 HORIZONTAL
FSD-7-4 LEVEL 7 EAST SUPPLY 20 14 HORIZONTAL
FSD-7-5 LEVEL 7 WEST RETURN 36 20 HORIZONTAL
FSD-7-6 LEVEL 7 WEST SUPPLY 26 14 HORIZONTAL
FSD-7-7 LEVEL 7 WEST SUPPLY 14 14 HORIZONTAL
FSD-7-8 LEVEL 7 NORTH SUPPLY 20 14 HORIZONTAL
FSD-8-1 LEVEL 8 WEST SUPPLY 30 20 HORIZONTAL
FSD-8-2 LEVEL 8 WEST RETURN 36 20 HORIZONTAL
FSD-8-3 LEVEL 8 WEST RETURN 114 42 HORIZONTAL
FSD-8-4 LEVEL 8 EAST SUPPLY 36 18 HORIZONTAL
FSD-8-5 LEVEL 8 EAST RETURN 114 42 HORIZONTAL
FSD-8-6 LEVEL 8 EXHAUST EXHAUST 26 16 HORIZONTAL
FSD-8-7 LEVEL 8 EAST RETURN 40 20 HORIZONTALGENERAL NOTES:A) FIRE SMOKE DAMPERS SHALL FAILSAFE IN CLOSED POSITION UNLESS OTHERWISE NOTED
NUMBERED NOTES:1) PROVIDE GRILLE ACCESS ACTUATOR
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:1
8 P
M
05.22.2015
1309100
M-603
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALSCHEDULES
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
C
H
T
CD
T
TT
NC/FIP
SA
NOT USEDNO SCALE
2 MISC POINTSNO SCALE
1
BMS INTERFACE WITH VRF CONTROL SYSTEMNO SCALE
5
RADIANT FLOORNO SCALE
9
RAINWATER RECLAIM CONTROL INTERFACENO SCALE
4 TRANSFER VAULT VENTILATION SUPPLYNO SCALE
3
HYDRONIC UNIT HEATERNO SCALE
8 VAV FAN POWERED TERMINAL UNIT WITH HEATING COILNO SCALE
7 VAV SINGLE DUCT TERMINAL UNIT WITH HEATING COILNO SCALE
6
SPACE TEMPERATURE SENSOR(MONITORING ONLY)
SPACE TEMPERATURESENSOR
(FAN CONTROL)
ASCLO
HI
T
C
H
1
2
33
2 21
CSR
LOHI
M
M
S/S
M/S BYDIV. 26(TYP)
M
ROOM TEMP.
PUMP STATUS
PUMP/FILTER ALARM
CITY WATER CONTROLVALVE STATUS
TO RAINWATERCAPTURE SYSTEM
CISTERN WATER LEVEL
NETWORK
CISTERN LOW LEVEL ALARM
DAY TANK HIGH LEVEL ALARM
DAY TANK LOW LEVEL ALARM
DOMESTIC COLD WATER FILL METER
RAINWATER FLOW METER
PUMP STATUS
PUMP ALARM
SUMP PUMP CONTROL PANEL
CS
S/S
CS BY BMS
M/S BYDIV. 26(TYP)
PUMP STATUS
PUMP ALARM
DW BOOSTER PUMP CONTROL PANEL
VISIBLE ALARM LIGHT
ACTIVATE LIGHT IF FAN DOES NOT OPERATE WHENTEMPERATURE CONTROLLER CALLS FORVENTILATION, IF THE FAN BECOMES INOPERABLE,OR IF TEMPERATURE EXCEEDS MAXIMUMALLOWABLE (140 F).
INTERLOCKED LINE VOLTAGE DAMPERSINGLE POINT POWER CONNECTION
RAINWATER MASTERCONTROL PANEL
NOTES:1) RAINWATER MASTER CONTROL PANEL (MCP) PROVIDED AS PART OF COMPLETE RAINWATER HARVESTINGSYSTEM (BY DIV 22).
2) ALL WIRING FROM MCP TO BMS BY CONTROLS CONTRACTOR
3) MASTER CONTROL PANEL SPECIFIED TO PROVIDE DIRECT EXTERNAL DATA COMMUNICATION PROTOCOLCOMPATIBLE WITH BUILDING AUTOMATION SYSTEM (BACNET). COORDINATE REQUIREMENTS WITH RAINWATERHARVEST SYSTEM PROVIDER.
(TYP-2)
(TYP-2) (PULSE)
(PULSE)
OUTSIDE AIR TEMPERATURE
OUTSIDE AIR CARBON DIOXIDE
BMS SHALL TURN DOMESTIC HOTWATER PUMP ON/OFF BASED ONBUILDING OCCUPANCY SCHEDULE TOTURN OFF CIRCULATING PUMPSWHEN BUILDING IS UNOCCUPIED.
BY DIV. 22
TO DHW CIRC PUMP (BY DIV 22)
DHW SUPPLY TEMPERATURE
BY DIV. 22
NUMBERED NOTES1 EMBED TUBING INTO SLAB TO ALLOW A SLAB TEMPERATURE SENSOR TO BE INSTALLED AND
REPLACED. SENSOR SHALL BE NO LESS THAN 1M (3FT) FROM EDGE OF SLAB.
DI
DOAO
M
NO
NCC
AI T
1
TO RADIANTFLOOR MANIFOLD
R
S
SR
AI
M
TEMPROOM
T
SUPPLY AIRPRIMARY AIR
LOHI
ASC
ROOM TEMP AI
C
H
DIOVERRIDE
NO
SENSOR
1. CO2 ON SELECT UNITS. SEE MECH SCHEDULE.2. INTERFACE WITH LIGHTING OCCUPANCY SENSOR IN EACH SPACE THAT CONTAINS
LIGHTING OCCUPANCY SENSOR. SENSOR PROVIDED BY DIV 26.3. HEAT COIL ON SELECT UNITS. SEE MECH SCHEDULE. IF NO HEATING COIL DAT SENSOR
AND VALVE NOT REQUIRED.
AISETPOINT
CO2ROOM
SENSOR CO2AIOCCUPANCYSENSOR
NOTES:
(ADJUSTABLE)
BMS NETWORK
DI
SUPPLY AIR
1. CO2 ON SELECT UNITS. SEE MECH SCHEDULE.2. OCCUPANCY SENSORS ON SELECT UNITS. SEE MECH SCHEDULE. OCCUPANCY SENSOR IS
SAME SENSOR AS LIGHTING. PROVIDED BY DIV 26. WIRE IN SERIES/PARALLEL TO CONNECTTO 1 DI.
3. HEAT COIL ON SELECT UNITS. SEE MECH SCHEDULE.
OCCUPANCYSENSOR
OCCUPANCYTEMP
SENSOR
SETPT
CO2CO2
ROOMROOM TEMP AI
DIOVERRIDE SENSOR
AI
SENSOR
ROOM
AI
BMS NETWORK
ECM
AO
DI
NOTES:
LOHI
PRIMARY AIR
RETURN AIR
AI
1. FAN ON-OFF CONTROL FROM LOCAL THERMOSTAT.2. PROVIDE ALL EQUIPMENT AND WIRING IN ACCORDANCE WITH SNOPUD SPECIFICATIONS3. ALL WIRING BY DIV 23
NOTES:
TO HEAT PUMPCONTROLLERS
TYPICAL
CONTROLPOINTS
HEAT PUMP
DOHEAT PUMP ON/OFF
DOHEAT PUMP OPERATION MODE
AIHEAT PUMP SPACE TEMPERATURE
AOHEAT PUMP SPACE TEMPERATURE SETPOINT (COOLING)
DIHEAT PUMP ALARM
DIOUTDOOR UNIT ALARM
AIOUTDOOR UNIT MODE STATE
1. VRF CONTROLLERS AND INTERFACE PROVIDED BY HEAT PUMP MANUFACTURER AND WIRED BY THE CONTROLS CONTRACTOR.
NOTES:
BACNETINTERFACE
VRFCONTROLLER
OUTDOORUNIT
CONTROLPOINTS
2. PROVIDE 5 DEGREE DEADBAND CONTROL ON FAN COIL OPERATION.3. THERMOSTATS IN ZONES SERVED BY VRF FAN COILS SHALL BE PROVIDED BY HEAT PUMP MANUFACTUER AND WIRED BY THE CONTROLS CONTRACTOR.
AOHEAT PUMP SPACE TEMPERATURE SETPOINT (HEATING)
AIHEAT PUMP FILTER RUN TIME
DI
DI
DI
AI
DI
DI
DI
DI
DI
AI
AI
DI
DI
DI
DO
AI
DI
DI
LINE VOLTAGETHERMOSTAT
ROOMTEMPERATURE
SENSOR
AIAI
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:1
9 P
M
05.22.2015
1309100
M-701
NEW SNOHOMISHCOUNTYCOURTHOUSE
MWL
CSG
MECHANICALCONTROLDIAGRAMS
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
1
1
CHILLED WATER PLANTNO SCALE
6
BOILER WATER PLANTNO SCALE
2 TYPICAL PUMP CONTROL WITH VFDNO SCALE
1
CONDENSED WATER PLANTNO SCALE
4 NOT USEDNO SCALE
3
NOT USEDNO SCALE
5
CWR
DP
M
M
M
M
DO
AO
DPS
AI
NOTE:1. MODULATE PUMP SPEED TO MAINTAIN REQUIRED DIFFERENTIAL PRESSURE, ASDETERMINED DURING HYDRONIC SYSTEM TEST AND BALANCING.
2. PROVIDE LINEAR RESET HOT WATER SUPPLY TEMPERATURE TO A MINIMUM OF 100DEGREES F BASED ON ZONE HOT WATER FLOW DEMAND.
LOCATE 2/3 OF THE WAYDOWN HW PIPING SYSTEM
WALL MOUNTWITHIN 18" AFF
INTERLOCK WITHOPERATION OF BOILERAND DHW HEATERS
LOCATE 2/3 OF THE WAYDOWN HW PIPING SYSTEM
AI
HWS
RETURN WATERSENSOR
T
T
HWR
AI
B
AI
HOT WATERBTU METER
24VAC
AO
AI
CO
CONTROLPANEL
VFD
BMS NETWORK
S/S
SPEED AO
DO1
1 NETWORK CONNECTION SHALL PROVIDE READ OR READ/WRITE OF ALL CONTROL POINTSAVAILABLE FOR INTEGRATION.
T
AI
T
AIPAI
F
AI
TO CHILLERS
PRESSURESENSOR
CWR
CWS
CWR
CWSAO
T
AI
T
AI
AO
S/S
SPEED
DI
SAFETY
LOAD BYPASS CONTROL
TEMPERATURE CONTROLT
AI
BMS NETWORK
WATER COOLED CHILLER
BMS NETWORK
M
M
T
AI
T
AI
EVAPORATOR
CONDENSER
CHILLERISOLATIONVALVE
CHILLERISOLATIONVALVE
DO
DO
DOS/S
AOSETPT
DI
DPS
AI
AI
T AI T AI
DI
EMERGENCY BOILER SHUTDOWNLOCATED OUTSIDE OF BOILER ROOM
(TYP-2)
BOILER CONTROL PANEL
DO
AO
DI
BMS NETWORK
STATUS DI
PANELCONTROL
VFD
VIBRATIONSWITCH
AI
1 ALL PUMPS ON VFDS. SEE 1/M-702.
AI
1 ALL PUMPS ON VFDS. SEE 1/M-702.
SUPPLY WATERSENSOR
AI
T
AI
T
AI
ENABLE
STATUS
DI
WATER COOLED CHILLER
BMS NETWORK
M
M
T
AI
T
AI
EVAPORATOR
CONDENSER
CHILLERISOLATIONVALVE
CHILLERISOLATIONVALVE
DO
DO
DOS/S
AOSETPT
DI
DPS
AI
DPS
AIDI
T
AI
T
AI
CHWS
CHWR
AOAILOADBYPASSCONTROL
DPAI
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:2
1 P
M
05.22.2015
1309100
M-702
NEW SNOHOMISHCOUNTYCOURTHOUSE
MWL
CSG
MECHANICALCONTROLDIAGRAMS
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
HEAT RECOVERY DOAS UNITSNO SCALE
2 NOT USEDNO SCALE
1
NOT USEDNO SCALE
3
NOT USEDNO SCALE
4VAV AIR HANDLING UNITNO SCALE
5
ALARM
T
ALARM
AI
AI
AIAI
AO
AI
AO
DI AIAI
AI
AIAI
AO
AO
DO
AI
AO
DO
AO
AO
T
OSA
EA RA
T
AI
N.C.
AIR TO AIRHEAT RECOVERY SYSTEM
CONTROLPANEL
VFDBMS NETWORK
CONTROLPANEL
VFD S/S
SPEED AOBMS NETWORK
DPT
N.C.
DPT
AI
SMOKE DETECTOR
DIOA FLOW
AF
AI
AI
S/S
SPEED AO
T
AI
AI
SAS.R.N.C.
M
24VAC
POWER
AFMS
T
OSA
EA RA
OA FLOW
AF
T
DPT
M
24VAC
SA
SP
DUCT STATIC
N.C.
CONTROLPANEL
VFD S/S
SPEED
BMS NETWORK
C
H
T
CONTROLPANEL
VFD
S/S
SPEED
BMS NETWORK
N.C.
N.O.
DPT
C
C
CO2
S.R.N.O.
T
SMOKE DETECTOR
DI3
RH
HIGH STATICSAFETY SWITCHSET AT 5 INWC
LT
DI
5
M
24VAC
POWER
AFMS
S.R.N.O.M
24VAC
M
M
DO
DO
T
AI
M
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:2
2 P
M
05.22.2015
1309100
M-703
NEW SNOHOMISHCOUNTYCOURTHOUSE
MWL
CSG
MECHANICALCONTROLDIAGRAMS
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
LEVEL 5
LEVEL 6
LEVEL 7
LEVEL 8
BASEMENT LEVEL
ROOF
AHU-R-1
(1850)
(1000)
(2750)
(2500)
(1700)
(3800) (8,000)
(6,000)
GENERAL NOTES:
A. ALL SHAFT PENETRATIONS SHALL INCLUDE FIRE SMOKE DAMPERSAHU-R-2
(5,000)
(6,000)
(6,000)
(6,000)
(11,000)
(7,500)
(2350)
(1500)
(6,000)
(5,500)
(5,000)
(17,000)
(7,000)
(7,000)
(14,000)
(7,000)
(2750)
(2750)
(21,500) AHU-R-3AHU-R-4
(4,250)
(4,250)
(2,000)
(4,250)
(4,250)
(4,250)
(4,250)
(4,000)
(4,250)
(4,250)
DOAS-R-1
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:2
4 P
M
05.22.2015
1309100
M-801
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICAL AIRRISER DIAGRAM
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
TO DRAIN
HWS
HWR
HWS
HWRHWS
HWR
HWR
HWS
CHW
R
CHW
S
CHWS
CHWRCHWS
CHWR
CHW
S
CHW
R
CWR
CWS
LEVEL 8
ROOF
LEVEL 7
LEVEL 6
LEVEL 5
LEVEL 4
LEVEL 3
LEVEL 2
LEVEL 1
LEVEL B
LEVEL 8
ROOF
LEVEL 7
LEVEL 6
LEVEL 5
LEVEL 4
LEVEL 3
LEVEL 2
LEVEL 1
LEVEL B
BOILER ROOMSEE HYDRONIC DIAGRAM
ON SHEET M-803
CHILLER ROOMSEE HYDRONIC DIAGRAM
ON SHEET M-803
8"
8"
6"
6"
6"
1 1/2" HEATING WATER SUPPLYAND RETURN BRANCHPIPING FOR FAN POWEREDBOXES ON EACH FLOOR
8"
4"6"6"
6" 4" 4"
4"
6"
4"
4"
2-1/2"2-1/2"
AHUR-1 AHU
R-3
AHUR-2AHU
R-4
CT1
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:2
5 P
M
05.22.2015
1309100
M-802
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALHYDRONIC RISERDIAGRAM
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
12" = 1'-0"M-8021 HYDRONIC RISER
CHWRCHWS
CWR
CWS
CWP1
CWP2
CWP3
CH1
CH2
CHWP1
CHWP2
CHWP3
AS1 ET
1
EVAPORATOR
CONDENSEREVAPORATOR
CONDENSER
TO COOLING TOWER TO BLDG RISERS
8"
6"
6"
6"
6"
6"
6"
8"
6"
6" 6" 6"
6"
6" 6" 6"
6"
6"
6" 6"
F
F
F
F
SEE PLUMBINGDRAWINGS FORMAKE-UP WATERPIPING
HWR
HWS
HWP1
HWP3
HWP2
AS2
B1
B2
ET2
TO BLDG RISERS
4"
4"
4"
4"
4"
4"
6" 6"
F F
SEE PLUMBINGDRAWINGS FORMAKE-UP WATERPIPING
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:2
7 P
M
05.22.2015
1309100
M-803
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
CHILLER & BOILERHYDRONIC PIPINGDIAGRAM
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT
12" = 1'-0"M-8031 CHILLER HYDRONIC PIPING DIAGRAM
12" = 1'-0"M-8032 BOILER HYDRONIC PIPING DIAGRAM
Drawing No.
Date:
Job No:
Checked By:
Drawn By:
Drawing Title
Revisions
Consultants
CIVILMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
STRUCTURALMKA1301 5TH AVE #3200SEATTLE, WA 98101T 206-292-1200
MECHANICALWSP GROUP600 UNIVERSITY ST, SUITE 500SEATTLE, WA 98101T 206-342-9900
ELECTRICAL / TELCOM / AVSPARLING4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0555
LANDSCAPESITE WORKSHOP222 ETRURIA ST #200SEATTLE, WA 98109T 206-285-3026
LIGHTINGCANDELA4100 194TH ST SW #400LYNNWOOD, WA 98036T 206-667-0511
Heery International Inc.4700 Millenia Blvd.,Suite 550Orlando, FL 32839407.992.6300
SECURITY ELECTRONICSGUIDEPOST SOLUTIONS388 17TH STREET SUITE 230OAKLAND, CA 94612T 510-268-8373
5/21
/201
5 6:
19:2
8 P
M
05.22.2015
1309100
M-804
NEW SNOHOMISHCOUNTYCOURTHOUSE
Checker
Author
MECHANICALREFRIGERANTDIAGRAM
2933 Rockefeller Ave.Everett, Washington 98201
DESIGNDEVELOPMENT