PREFLARING & GLIDE PATH– DEFINITION
Preflaring is the preliminary root canal enlargement needed to reduce the risk of taper lock of the tip of the first rotary instrument used to shape the canal.
Glide Path is obtained during preflaring and corresponds to the smooth canal preparation that rotary instruments can follow without the risk of blockage or bending.
Until now, this stage is conventionally performed with hand SST instruments, such as K-Files 008, 010 or 015.
![Page 4: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/4.jpg)
PREFLARING & GLIDE PATH– IMPORTANCE
Study conclusions
By creating a canal (a Glide Path) at least as large as the diameter of the NiTi rotary instrument that will be used successively (and which has a greater taper), drastically reduces the torsional stress and, therefore, the risk of file separation.
![Page 5: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/5.jpg)
PREFLARING & GLIDE PATH– IMPORTANCE
Glide Path is an essential step:
- to fully understand and appreciate the anatomy of the canal to be treated (i.e. mentally develop a three dimensional image of the canal system to shape)
- to reduce the risk of rotary instrument breakage
![Page 6: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/6.jpg)
MANUAL PREFLARING – PROBLEMS
The initial preflaring and glide path are normally carried out with stainless steel hand files.
Because of the relative stiffness of these instruments, it can be difficult to avoid the risk of:
- canal transportation
→ may lead, in severe cases, to root canal perforation
![Page 7: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/7.jpg)
MANUAL PREFLARING – PROBLEMS
Because of the relative stiffness of these instruments, it can be difficult to avoid the risk of:
- ledges
→ the tip could block in the canal and, if not withdrawn but pushed apically, could eventually break
- apical zip
→ may lead to obturation difficulties
![Page 8: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/8.jpg)
PREFLARING & GLIDE PATH – NEW SOLUTION
PathFile™, a new rotary Nickel-Titanium solution for Mechanical Glide Path and Preflaring
A new range available in 3 ISO sizes (013, 016 and 019) and 3 lengths (21, 25 and 31mm).Flexible and resistant to cyclic fatigue, they offer many advantages compared to manual solutions.
![Page 9: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/9.jpg)
PATHFILE™ – STANDARD SEQUENCE
Scout and negotiation with a standard K-File #010 until it can move smoothly along the canal
With same file, working length determination in combination with an Apex locator
PathFile™ #013 to working length
PathFile™ #016 to working length
PathFile™ #019 to working length
Canal shaping with any NiTi rotary system
![Page 10: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/10.jpg)
PATHFILE™ – OTHER SEQUENCES
LARGE AND EASY CANALS
If it is possible to reach the full working length with a K-File #020, the Glide Path is not necessary and no PathFile™ will therefore have to be used.
![Page 11: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/11.jpg)
PATHFILE™ – OTHER SEQUENCES
“INTERMEDIATE” CANALS
If the user feels, during the initial scouting with the K-File 010, that the canal is rather wide, the recommendation is to use either PathFile™ 016 and 019 or even only PathFile™ 019.
![Page 12: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/12.jpg)
PATHFILE™ – OTHER SEQUENCES
THIN, CUVED, CALCIFIED CANALS
In these cases the standard sequence is recommended, i.e. PathFile™ 013, 016 and 019
![Page 13: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/13.jpg)
PATHFILE™ – DIRECTIONS FOR USE
Rotation speed ≈ 300 rpm
Instruments should be used with a delicate in/out movement until they reach the full length. Strong axial forces should therefore be avoided.
Time needed to reach working length normally does not exceed 3-5 seconds/file
The rotating motion will carry debris in a coronal direction
![Page 14: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/14.jpg)
FEATURES AND BENEFITS
Development in collaboration with Prof Berutti, Prof Cantatore and Dr Castellucci
support of 3 internationally renowned Opinion Leaders as well as of the Dentsply Maillefer OPL network
quality evidence thanks to their expertise
![Page 15: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/15.jpg)
PATHFILE™ – FEATURES & BENEFITS
NiTi – Square Section – 2% Taper
high strength against cyclic fatigue
flexibility
Tip diameters (013-016-019)
gradual increase that facilitates the progression of the files without the need for strong axial pressure
![Page 16: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/16.jpg)
PATHFILE™ – FEATURES & BENEFITS
Tip design (transition angle reduction)
Reduced risk of ledges and canal transportation
PathFile™ K-File
![Page 17: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/17.jpg)
PATHFILE™ – STUDY CONCLUSION
The study carried out by Prof Berutti, Prof Cantatore and Dr Castellucci clearly shows that, when compared to manual instruments, PathFile™:
1. better maintains the original canal anatomy → less canal transportation and canal aberrations
2. is more forgiving procedural errors such as incorrect working length
→ no apical transport when WL is too long→ no ledges when WL is too short
![Page 18: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/18.jpg)
PATHFILE™ – STUDY CONCLUSION
The study carried out by Prof Berutti, Prof Cantatore and Dr Castellucci clearly shows that, when compared to manual instruments, PathFile™:
3. reduces the instrumentation time needed
4. allows General Dental Practitioners to obtain similar results to those achieved by endodontists
![Page 19: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/19.jpg)
PATHFILE™
EXAMPLE TREATMENTS
![Page 20: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/20.jpg)
PATHFILE™ – EXAMPLES
Prof. Elio Berutti
![Page 21: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/21.jpg)
PATHFILE™ – EXAMPLES
Prof. Elio Berutti
![Page 22: MECHANICAL GLIDE PATH & PREFLARING NEW ROTARY NiTi INSTRUMENTS FOR](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649cc45503460f9498de35/html5/thumbnails/22.jpg)
PATHFILE™ – EXAMPLES
Prof. Elio Berutti