mechanical cad details - autocad, construction · pdf fileair-cooledchiller piping connection...

73
t t LVE BLE SOCKET WELL) RE GAUGE VALVE PTO ANGE ER) \ PRESSU WIGATE I ,", LEFT SIDE II II II __ II II 2-1/2") FL (3" & OV •• ';:.() ,<- .. T '00' :Of'."fJ '!' .. '. '00" ';0 '!J 1i:1;"OQjj'<lff'..j""" ".'0:,"" ?p' '0 6" CONCRETE PAD / SEPARA CONTROL PANEL J (GAUGE - FLEXIBLE CONNECTION CHILLED WATER S & R GATE VA AIR-COOLED CHILLER PIPING CONNECTION DETAIL Samples from www.AutoCADDetails.net

Upload: vuthien

Post on 05-Feb-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

t t

LVE

BLE SOCKETWELL)

RE GAUGEVALVE

PTOANGE

ER)

~I~ ~ ~II\ PRESSU

WIGATE

I rrr~,~_,,",~UNION(U

LEFT SIDE

II II II __ IIII 2-1/2") FL

(3" &OV

~••"-..A.~l)t\ ';:.() ~,"?..A.~~.~. ,<- .~..,·o.,;:~,"?..,

..T'00' :Of'."fJ '!' .. '. '00" ';0 .o~'" '!J 1i:1;"OQjj'<lff'..j"""

~-~".'0:,"" ?p' '0

6" CONCRETE PAD / SEPARA

CONTROL PANEL

J(GAUGE

- FLEXIBLE CONNECTION CHILLED WATER S & R GATE VA

AIR-COOLED CHILLER PIPING CONNECTION DETAIL

Samples from

www.AutoCADDetails.net

Page 2: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

AQUASTAT

L- COMBINATION PRESSURE ANDTEMPERATURE GAGE

l MULTI PURPOSE VALVE(GATE, BALANCING, CHECKAND METERING), TYP

CIRCULATING PUMP[HWP-1]

CHEMICAL POT FEEDER

SEE DETAIL

PRESSURE GAGE, TYP

OUTDOOR AIR THERMOSTATSETATdF

[ET-1] DIAHRAGM

EXPANSION TANKSEE DETAIL

/

AUTOMATIC AIR VENT

FROM HEATING SYSTEM

AIR SEPARATOR

GATE VALVE, TYP

FLEXIBLE TYPE MECHANICAL COUPLINGS TYP.

SUCTION DIFFUSER

TODRAIN '\

COMBINATION BOILER FEED ANDLOW WATER CUT-OFF

3-WAY CONTROL VALVEVLV-B1-01

LOW WATER CUTOFF

CW MAKE-UP, -

PRESSURE RELIEF VALVE,DISCHARGE TO FD

PRESSURE REDUCING

VALVE SET AT PSIG . ~~THERMOMETER(Od - 250dF) TYP \

~ r [f+-4-------------h

[B-1] -------ct~~-:I

PRESSURE---~RELIEF VALVESETATPSIG,

TERMINATERELIEF VALVEPIPING 6" AFF.

BOILER PIPING SCHEMATIC

Samples from

www.AutoCADDetails.net

Page 3: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

,------ FOR DETAIL OF ROOFFLASHING SEE ARCH.DRAWINGS

[---

,--------- VENT STORM COLLAR

~-t__---DOUBLE WALL POSITIVE

PRESSURE TYPE SMOKESTACK

3'-0" ABOVE ROOF(5'-0" FOR NATURALDRAFT BOILERS)

RAIN CAP -----~~~~-~-,::::-..

/

ROOF SUPPORT--~ASSEMBLY

·~----14" DIA INSIDE DIA. STACKFROM BOILERS. SEE DWG.M-4 FOR STACK LAYOUT.

BOILER STACK DETAIL

Samples from

www.AutoCADDetails.net

Page 4: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

SEE PLAN FORSIZE &CAPACITIESOF UNIT r- LINTEL

INVERTED FLOWI

/

PROVIDE 1" RIGID INSULATIONIF UNIT IS LOCATED ONOUTSIDE WALL

6" UNLESS NOTED I \ /OTHERWISE -"~

l~ --------=========--1

CABINET HEATER DETAIL

Samples from

www.AutoCADDetails.net

Page 5: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

THERMOSTA

----- GATE VALVE

,-++--L--+----j I 11----1

\ COIL

~ UNION

BALANCING COCK ---<

MANUAL AIR VENT

FLOW METERINGDEVICE

HWR

HWS

t FASTEN BULB TOR.A. BACKPLATE

4"RUN PIPING BACKTO WALL

CABINET HEATER PIPING DETAIL

Samples from

www.AutoCADDetails.net

Page 6: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

ELBOW SUPPORT

FLOOR

GROUT

FLOOR FLANGE

BUTTERFLY VALVE (TYPICAL)

VIBRATION ISOLATOR (TYPICAL)

CHECK VALVE

PRESSURE GAGE WITH SERVICECOCK (RANGE AS SPECIFIEDON DRAWINGS)

~- GUARD

PUMP

MOTOR

ANCHOR PUMP TO 4" THICKCONCRETE BASE. BASE IS 3" LARGERTHAN PUMP IN BOTH DIMENSIONS

DRAIN VALVE

MIN. STRAIGHT PIPE 5 XDIAMETER SUCTION OR USESUCTION DIFFUSER

(BASE MOUNTED)

CENTRIFUGAL PUMP

Samples from

www.AutoCADDetails.net

Page 7: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

GATE VALVE

STRAINER WITHBLOWDOWN

CONCENTRICREDUCER(TYPICAL)

ELBOW SUPPORT

FLOOR

GROUT

FLOOR FLANGE

1/4"

GATE VALVE

FLOW CONTROL-BALANCING VALVE

VIBRATION ISOLATOR (TYPICAL)

CHECK VALVE

PRESSURE GAGE WITH SERVICECOCK (RANGE AS SPECIFIEDON DRAWINGS)

PUMP

MOTOR

ANCHOR PUMP TO 4" THICKCONCRETE BASE. BASE IS 3" LARGERTHAN PUMP IN BOTH DIMENSIONS

1/2" DRAIN VALVE

MIN. STRAIGHT PIPE 5 XDIAMETER SUCTION OR USESUCTION DIFFUSER

(CLOSE COUPLED)

CENTRIFUGAL PUMP

Samples from

www.AutoCADDetails.net

Page 8: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

MANUAL-\VENT

~/9//f$J/

CHILLED WATER COIL

Samples from

www.AutoCADDetails.net

Page 9: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

FILTER SECTION

RAISED FLOOR

RETURN AIR

COMPUTER ROOMAIR CONDITIONING UNIT

SUPPLY AIR

BUILDING FLOOR

C.W. SUPPLYTO HUMIDIFIER

HOSE ENDDRAIN VALVE

D

GLYCOL PIPES

-~~ SUPPLY AIR

L CONDENSATE DRAINLINE

GATE VALVE

COMPUTER ROOM AIRCONDITIONING UNIT DETAIL

Samples from

www.AutoCADDetails.net

Page 10: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

PRESSURE RELIEF VALVESEE SCHEDULE -----------,

PRESSURE GAGE

VACUUM BREAKER

STEAMSUPPLY

CONTROL VALVESEE SCHEDULE

BY-PASS IF STEAMSUPPLY LINE ISGREATER THAN 2"

BY-PASS SAME SIZEAS CONTROL VALVE

CONVERTER

PIPE TOFLR. DRAIN

TRAP-SEE SCHEDULE

~---------------~

CONDENSATE RETURN - -///?THERMOMETERRANGE 0 TO 250 F --------'

CONVERTER PIPING DETAIL

Samples from

www.AutoCADDetails.net

Page 11: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

CONVERTOR

BOLT SADDLE TO FRAME

-----++--+------++--

CAST STEEL FRAME

4'-0'

6"X6"X1/2"STEELPLATES(ALL LEGS)

2"X2"X1/4"S

2 X CONVERTORDIAMETER

FLOOR LINE

CONVERTOR SUPPORT DETAIL

Samples from

www.AutoCADDetails.net

Page 12: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

THERMOMETER

STRAINER AUTOMATIC CONTROL VALVE

UNION

AIR VENT

GATE VALVE

BALANCING COCK

3/4" DRAIN VALVEWITH HOSE CONNECTION

FLOW METERING DEVICE

COOLING COIL PIPING DETAIL

Samples from

www.AutoCADDetails.net

Page 13: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

BUTTERFLY VALVE, TYP.~ (BOLT-IN TYPE VS. BOLT THRU)

~I~ ~ CDR FROM CHILLERBYPASS, CONNECT

00 THE TOWER BASIN PERr+------+---------I THE MFR'S RECOMMENDATIONS

------VACUUM BREAKER,1/ ~~STEAMCONTROLVALVE'~ SEE CONTROL DIAGRAM

GATE VALVE

~~~"LPS'CONNECTTO~1 TOWER BASIN STEAM

COIL

I STRAINER

l~lf------N------t~ CDS TO PUMP"--------- CONDENSATE

TOFLOAT & THERMOSTATIC STEAM TRAP,

LBS/HR AT PSI DIFFERENTIAL PRESSURE

6"

MIN. 12"

BUTTERFLY VALVE------~

NOTES:

1. PROVIDE THERMOSTATICALLY-CONTROLLED ELECTRIC SELF-LIMITING HEAT TRACING TAPE UNDERNEATHTHE INSULATION ON ALL NEW PIPING LOCATED OUTDOORS EXCLUDING THE STEAM, CONDENSATE, AND DRAINPIPING SERVING THE TOWER. LOCATE THE THERMOSTAT AS SHOWN ON THE PLANS WITH A SUN SHIELDAND SET IT TO ENERGIZE THE HEAT TAPE AT AN OUTDOOR TEMPERATURE BELOW 45 DEG. F.

2. PROVIDE PIPE SUPPORTS PER DETAIL ON SHEET. SPACE SUPPORTS IN ACCORDANCEWITH SECTION 15501 OF THE SPECIFICATIONS.3. INSTALL PIPING TO PERMIT COMPLETE MAINTENANCE ACCESS TO THE TOWER.

3/4" HOSEBIBB--------~

1/4" BLEED LINE ----"

DOM. WATER MAKE-UPPIPING, CONNECT TOTOWER FILL ASSEMBLY -------;.....--------f~--___h

BLEED VALVE, SEECONTROL DIAGRAM ---"

OVERFLOW AND DRAINPIPING, SAME SIZE ASTOWER CONNECTION, PIPE~EQUALIZING LINE

BETWEEN TOWERS, LOCATE _CONNECTION PER THE TOWERMFR'S RECOMMENDATIONS -_/

COOLING TOWER PIPING

Samples from

www.AutoCADDetails.net

Page 14: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

AIR FLOW

WATER IN -

BLEED LINE

COOLINGTOWER

BLEED VALVE

WATEROUT~/ .....1-----

~~-

COLDWATERMAKE UP DRAIN ----j---------' OVERFLOW

COOLING TOWER DETAIL

Samples from

www.AutoCADDetails.net

Page 15: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

X"CWRFROMCONDENSERWATER PUMP

,------+------1-1/4" CW MAKE-UPTO FLOAT VALVE

_-+-+--f------- FLOAT VALVE

2" DRAIN LINE __--+--+----lW/GATE VALVE

rh--~--+-----rf-------------11--tt--t--2" OVERFLOW TOGRADE DRAIN

X"CWSTOCONDENSER ~ ,, ---"WATERPUMP~

f--- GATE VALVE~SUPPLY & RETURN

CROSS-FLOW COOLING TOWER DETAIL

---+--- COOLING TOWER

COOLING TOWERSUPPORT FRAME.

~,------it--jj--- 6" CONCRETE PAD

GRADE

Samples from

www.AutoCADDetails.net

Page 16: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

TO NEXT DEVICE--

JCT. BOX

CEILING

DOOR SWITCHES ---+---++----/INSTALLED BYELEC. CONTR. /

r------TO NEXT DEVICE

--------CONDUiT CONCEALED INWAL & STUBBED INTO DOOR HEAD.'DOOR HEAD.

---------INSTALL BUSHINGON CONDUIT.

"'----'CABLE PULLEDINTO DOOR HEADAND CONNECTEDBY ELE. CONTR.

/

DETAIL-DOOR SWITCH INSTALLATION

Samples from

www.AutoCADDetails.net

Page 17: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

NOTE TO DESIGNER:

N.S.P.C. 10.16.7 REQUIRES: WHERE A HOTWATER STORAGE TANK OR INDIRECT WATER HEATER IS LOCATEDAT AN ELEVATION ABOVE THE FIXTURE OUTLETS IN THE SYSTEM AVACUUM RELIEF VALVE SHALL BE INSTALLED ON THE STORAGE TANK.

COMBINATION TEMPERATUREAND PRESSURE RELIEFVALVE-----~

DRAIN--·~I

HOT WATER SUPPLY

r--- COLD WATER

~-VACUUMRELIEF VALVE

~ . GATE VALVE, TYPICAL

"'---- UNION, TYPICAL

..--+----DIP TUBE INSIDE

OF TANK

.~SEISMIC STRAP•

AQUASTAT -------­TYPICAL

~

HEATING /ELEMENTTYPICAL-

HOSE BIBB

r--- 4" HOUSEKEEPING PAD

~FLOOR

DOMESTIC ELECTRIC WATER HEATER

Samples from

www.AutoCADDetails.net

Page 18: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

CIRCULATINGPUMP

~STRAINER

RESSUREAUGE

PRESSURE AND

/

- TEMPERATURE RELIEF VALVE

f1RE.LIEF VALVE /-VENT TO ROOF

r- ROUTE PIPE/ TO 12" AFF

~~~GE l$·l //~WATERHEATER

MIXINGVALVE

THERMOMETERS \

III

110 F SUPPLY ~

COLD WATER \ .-/SUPPLY ~

DOMESTIC HOT WATER SCHEMATIC DETAIL

Samples from

www.AutoCADDetails.net

Page 19: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

f-------------- L ----------

-----W-------

A" HOTWATER OUTLET

1-----W----

n

---

[~

H

o

E

PUMP

- If---rr---++-------+---~

THERMOSTATIC 7SENSING BULB

f------- D ---+------f-

'------tt---------------'y- If------++-------+---------,

WRAPPED ANDBAFFLED COIL

[

2" FIBERGLASS~INSULATION

L----++--------!.J)-1 DRAIN TI

STRUCTURAL BEAM SUPPORT SKID I\'-------------------------'----

STRAINER- \

STEAM IN II\F-i

J

I

ASME PRESSURETEMPERATURERELIEF VALVE

~DON I rREAR AUXILLARYV

TRAP~ lret-CONDENSATE ---j--<"l~~I

OUT MAINTRAP

B"COLDWATER INLET

CONTROL

VALVE~

STEAM WATER

PR~~~UREGAUGE GAU E

\ I \

THERMOMETER

VALVE6"-----:l

-----S-----

DOMESTIC HOT WATER TANK AND TANK HEATER WITH STEAM INPUT

Samples from

www.AutoCADDetails.net

Page 20: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

Samples from

www.AutoCADDetails.net

Page 21: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

;

- NUTS ANDWASHERS

~~~

GAL A B C D0-50 1/2" 2" 2" 1/4"

0-100 5/8" 3" 3" 1/4"

ANGLE "B"X"C"X"D"

CLIP ANGLEWELD TOSUPPORTANGLE

TO C.W. MAKE-UPCONTINUATION

IEXPANSION TANKSEE DWGS. FORSIZE

PRV SEE DWGS. FOROUTLET SETTING

FULL SIZE TO FLOORDRAIN

'~ AIR REMOVAL ~ TANK DRAIN ANDFITTING WI VENT CHARGE VALVE WI

HOSE COI\INECTION3/4" UP TO 7' HORIZ.1" 7' TO 70'

r RELIEF VALVE SEEDWGS. F R SETriNG

f--------'------_:x: f-j>,( f----j BFP f-----+--~, x f--

\ GAGE GLASS W/GUARD &\SHUT OFF VALVES

TO AIR SEPARATOR(0-100 GALLONS)

EXPANSION TANK

Samples from

www.AutoCADDetails.net

Page 22: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

ACCESS PANEL

MANUAL AIR VENT

BALANCING COCK ----l

GATE VALVE

CHWR

STRAINER

- UNION

COIL

CABINET

- FINISHED FLOOR

~-+-----D ---\ CONDENSATE DRAIN PANCHWS

FAN COIL UNIT PIPING DETAIL

Samples from

www.AutoCADDetails.net

Page 23: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

GATE VALVE -----,

AUTOMATIC CONTROL VALVE -----,

ACCESS DOOR

GLOBE VALVE

FLOOR

ECCENTRIC REDUCER WHEREPIPE SIZE CHANGES

====================================

1---- ACTIVE FINLENGTH

====================================1]PARTITION WALL

FIN TUBE RADIATION DETAIL

Samples from

www.AutoCADDetails.net

Page 24: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

STRIP 4" MIN. TO 9" MAX.L BE EQUAL ON BOTH ENDS.

4" MIN. MUST BE EQUALBOTH ENDS.

LOUVERS

TOP VIEW

'-

I I

<? SI

II III III

~~TRIM

~ i-E MUST

TOP OFFINISH FLOOR -~

NOTE:SYMMETRY SHALL ALSOBE MAINTAINED WHERE ENCLOSUREIS NOT INSTALLED BETWEENWALLS.

4" NOMINAL

~

L SECTIONS SHALL BE NO LONGER THAN5'-0" AND BE SYMMETRICAL BETWEENWALLS

ELEVATION

(TOP DISCHARGE)

FINTUBE ENCLOSURE DETAIL

Samples from

www.AutoCADDetails.net

Page 25: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

~lJlll 'fJ t~ L-_______ ~ TRIM STRIP 4" MIN. TO 9" MAX.MUST BE EQUAL ON BOTH ENDS.

TOP VIEW

LOUVERS 4" MIN. MUST BE EQUALBOTH ENDS

TOP OFFINISH FLOOR

NOTE:SYMMETRY SHALL ALSOBE MAINTAINED WHERE ENCLOSUREIS NOT INSTALLED BETWEENWALLS.

4" NORMAL

SECTIONS SHALL BE NO LONGER THAN5'-0" AND BE SYMMETRICAL BETWEENWALLS

ELEVATION

(FRONT DISCHARGE)

FINTUBE ENCLOSURE DETAIL

Samples from

www.AutoCADDetails.net

Page 26: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

THERMOMETER POSITIONED TO BEHOT WATER SUPPLY ~ J- I -------READ FROM FLOOR (RANGE 0-200DF)

ISOLATION GATE /; ~.~ .PIPE UNION (TYP)~OLD WATER SUPPLYVALVE(TYP)~ ~ ~

T T

ELECTRIC WATERHEATER----~

nP&T RELIEF VALVE

f-----n (SETTING BY MFR. OF HEATER)

cy-- FULL SIZE OF VALVEOUTLET

DRAIN nFIN.FL~O { ROUTE TEMPT. AND PRESS. VALVE<- OUTLET TO 15 CM OFF FLOOR

OR TO FLOOR DRAIN WHEN AVAILABLE... II \1I U " " .d \I;

dd

"Li.,.

/<J " 6 ~<J

<I

FLOOR MOUNTED ELECTRIC WATER HEATER DETAIL

Samples from

www.AutoCADDetails.net

Page 27: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

A

COMBINATIONBALANCING/SHUT­OFF VALVE ONDOWNSTREAM SIDEOF F.1.

FLOW

FLOW INDICATOR (F.I.)

I"

6 PIPE DIA. MIN. ",Ie 3 PIPE DIA. MIN."

STRAIGHT PIPE STRAIGHT PIPE

A

'" DIA. '"FLOW FLOW

WRONG

SECTION A-ASHOWING RELATIONSHIPOF FLOW INDICATOR TOUPSTREAM ELBOW

DO NOT LOCATE F.1. IN THISPOSITION RELATIVE TO UPSTREAMELBOW. LOCATE F.1. PARALLEL TOPIPE UPSTREAM OF ELBOW, NOTPERPENDICULAR. SEE SECTION A-A.

NOTES:

1. ONLY STRAIGHT PIPE IS TO BE WITHIN MINIMUMUPSTREAM & DOWNSTREAM DIMENSIONS, NO FITIINGSOR VALVES ARE ALLOWED.

2. F.1. & VALVES SHALL BE ORIENTED FOR EASY ACCESS.IF TOP OF PIPE IS CLOSE TO STRUCTURE OROBSTRUCTIONS, ARRANGE PIPING TO LOCATE VALVEOPERATOR & F.1. CONNECTIONS ON SIDE OF PIPE.NO VALVE SHALL BE INSTALLED WITH THEOPERATOR BELOW THE HORIZONTAL.

FLOW INDICATOR (F.I.) DETAIL

Samples from

www.AutoCADDetails.net

Page 28: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

~...............

2 1/4"MIN.

21/4"MIN.

.------ FLUSH VALVETAILPIECESUPPORT~.~~ ..... -d.. «-- .....= I

""'" a..N ~

FINISHED FLOOR

...J

...J

~-<'..........

I Ia.. a..~&;'..........

FINISHED FLOOR

FLUSH VALVE SUPPORT DETAIL

Samples from

www.AutoCADDetails.net

Page 29: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

DELUGE TYPEEMERGENCY SHOWER

SHOWER AND ~

EYE WASH SIGN~

HANDLE SHOWN INSTAY OPEN POSITION -----+-~

CHROME PLATED BRASSEYE WASH SPRAY HEADSW/PROTECTIVE COVERS -------"

(3) 3/8" ANCHOR BOLTSIN CONCRETE FOOTING --,

FINISHED GRADE -,

PUSHTO

OPERATE

.z~

<J

CONCRETE FOOTING

MIN. 3 CUBIC YARDSOF CRUSHED STONE --

FROST-PROOF VALVE WITH1-1/4" DRAIN DOWN WASTE ----~~

1-1/4" WATER SUPPLY INLET--~(REFER PLAN FOR ROUTING)

FROST-PROOF COMBINATIONDRENCH SHOWER/EYE WASH UNIT

Samples from

www.AutoCADDetails.net

Page 30: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

FINISH GRADE~ 550 GAL. OIL STORAGE TANK FINISH GRADE

1/2" DIA. X 18" L.EYE-TYPEANCHOR BOLT(TYP. OF 4)

1/2" WIRE CABLE(TYP. OF 4)

- 1/2" TURNBUCKLE(TYP. OF 4)

24"MIN.FIBERGLASS­REINFORCED HOLDDOWN STRAPS(TYP. OF 2)

1/2" TURNBUCKLES(TYP. OF 4)

1/2" DIA. X 18"L.ANCHOR BOLT(TYP. OF 4)

12" MIN.

o,

3'-0" DIA. X 5'-4"L. WITH 5'-0"W.

4'-0" DIA. X 5'-6"L. WITH 6'-0"W.X 6'-0"L. X 12" CONCRETE

HOLD DOWN MAT.275 GAL. OIL STORAGE TANK

STEEL

TANK

~+------:c~~~~iV(v.;jX6'-0"L. X 12"0. CONCRETEHOLD DOWN MAT.

6"MIN.

6"MIN.

~..~~

3"W. X 3/16"T.STEEL HOLD

DOWN STRAPS(TYP. OF 2)

COMPACTED SAND #5 AT 12" OIC BOTH WAYS ---------'PEA GRAVEL 1/4" NOMINALNATURALLY ROUNDEDAGGREGATE WIPARTICLESRANGING FROM 1/8" TO 3/8"DIA.-CLEAN AND FREE FLOWING.

FUEL OIL TANK ANTI-FLOTATION PAD &ANCHORAGE DETAILS

(TYPICAL FOR 275 &550 GAL. STORAGE TANKSWHERE EXISTING CONCRETE PADS ARE FOUND.)

Samples from

www.AutoCADDetails.net

Page 31: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

8'-0" ABOVEFINISH GRADE

//-- 2" FILL AT 1/4" PITCH/FT.BACK TO TANK

-- 2"VENT/ BACK TO TANK

2" VENT PIPE SCREWEDINTO VENT ALARM

2" VENT ALARM SCREWED INTOTANK (SEE VENT ALARM DETAIL

--+--+-Jl-Etj-- 1'-6"

o-'N

12"

EQUAL

2'X2'X1'CONCRETE

BUILDING WALL-~__

VENT CAP (SEE VENT CAP

1"W. X 1/16"T. STRAP NAILER(TYP. OF 2)

HINGED & LOCKING FILL CAP(SEE HINGED FILLCAP DETAIL

2'(@)

1'-6" X 1'-6" X1'-6" CONCRETE

EQUAL

FINISH GRADE

550 GAL OIL STORAGE TANK4'-0" DIA. X 5'-6"L.

275 GAL.OIL STOR. TANK3'-0" DIA. X 5'-4"L.

NEW 1/2 SUP. & RET. OIL LINESCONNECT TO EXISTING 1/2"

SUP. & RET OIL LINESWITH BRAZE FITTINGS. c:~~-+----­s-----------=----+-----,s--------o----­s--------o-----

SLIP-THROUGH TANKFITTINGS TYP. OF 2 FOR

550 GAL. TANK & 1 FOR 275GAL. TANK (SEE OIL TANK

LOCKING FLUSH TYPE FILL BOX

FUEL STORAGE TANK DETAIL

Samples from

www.AutoCADDetails.net

Page 32: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

WALL

TRAP AND PLUMBING ----------­CONCEALED IN WALL

COOLING UNITCONCEALED IN WALL------~

AIR GRILL----------~~I

FLOOR--~

NOTES:1. INSTALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS.

FULLY RECESSED DRINKINGWATER COOLER

Samples from

www.AutoCADDetails.net

Page 33: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

METAL FLUE UP THRU ROOF,SEE METAL FLUE DETAIL

~ BALL VALVE ORI ~ GAGE VALVE

~ X" C.W. INLET

~ DIELECTRIC UNIONS ASf-------n REQUIRED BY SPECS.BALL VALVE

TEMPERATURE-PRESSURE

RELIEFVALVE---~:=_~

/?/;Dll\X" H.W. OUTLET . T

RELIEF PIPE ------'- ~ WATER HEATER

GAS SUPPLY

SHUT OFF COCK

UNION

DIRT LEG

PIPE CAP

.------ DRAIN VALVEWITH HOSE END

GAS FIRED HOT WATER HEATER CONNECTIONS

Samples from

www.AutoCADDetails.net

Page 34: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

, DOMESTIC HOT WATER

/

. CIRCULATING PUIMP DWP-1SEE DETAIL

FLUE CONNECTION (CLASS "B")

DIELECTRIC UNIONS

GATE VALVE (TYP)

~----L-R-i--_~ X" C.W. INLET

COMBINED TEMPERATUREAND PRESSURE RELIEF VALVE

X" H.W. SUPPLY r-t7-------TO FIXTURES~

VENTPIPE~

DIELECTRIC UNION

DRAIN VALVE, ROUTE TOFLOOR DRAIN

1e--------3/4" CIRCULATING LINE

DIRT LEG

PIPE CAP

CONCRETE PAD~~__-----liJ_Lil-- _

3/4" GAS SUPPLY

SHUT OFF COCK

GAS FIRED HOT WATER HEATERCONNECTIONS WITH RECIRCULATING LOOP

Samples from

www.AutoCADDetails.net

Page 35: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

....UNIT

HEATER

TYPEBGAS VENT

UNION

GAS CONTROL VAL·(FURNISHED BY HEATERMANUFACTURER)

LJ.... 8" DIRT LEGW/CAP

BALL VALVE

GAS FIREDUNIT HEATER DETAIL

Samples from

www.AutoCADDetails.net

Page 36: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

SEE DETAILSFOR COMMON VENT DETAIL

1" X 16 GAUGE SEISMICSTRAP WfTWO 1/8" X 3"ANCHOR BOLT, TYP

'----- GATE VALVE,

I TYPICAL

;:'L--=r=-L1---=l~..__=;_-- UNION, TYPICAL1

PIPETO-----<>-i6"AFF

I~-----COLD WATER SUPPLY

~------CHECKVALVE

HOT WATER SUPPLY \ IN LINE RECIPROCATING PUMP [DCP-X]

VACUUM RELIEF ~ STRAP-ON AQUASTATVALVETYP T ~ SET FOR 100dF

COMBINATION TEMPERATURE l~~ HOT WATER RETURNAND PRESSURE RELIEF (T&P) ,+---L----c-lXt--t-4------{>,<J----'-_+,

VALVE, TYPICAL JI-I _

METAL FLEX TUBING, TYP

GAS COCK, TYP

TOGAS~DROP, TYP

BURNERCONTROLLER,TYP

I----+-----DIP TUBE INSIDEOF TANK, TYPICAL

BURNERTYP

r--r~._--HOSE FAUCET,TYP

6" HOUSE-KEEPING PAD--~

GAS FIRED WATER HEATERNOTE TO DESIGNER: N.S.P.C. 10.16.7 REQUIRES: WHERE A HOTWATER STORAGE TANK OR INDIRECT WATER HEATER IS LOCATEDAT AN ELEVATION ABOVE THE FIXTURE OUTLETS IN THE SYSTEM AVACUUM RELIEF VALVE SHALL BE INSTALLED ON THE STORAGE TANK.

Samples from

www.AutoCADDetails.net

Page 37: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

\~

6 GA. SHEET METAL(GALV.) FLASHINGCOLLAR

FLASHING & COUNTERFLASHING

ROOF00

WELD TO VENT

-AS REQUIRED FORDIFFERENT PIPESIZES

'--------- 1/2" ALL AROUND

WELD (TYP.)

1,,-tINSULATIONWHEREREQUIRED

~-+----- 1" X 1/8" X LENTHOF SLEEVE (4 REQ'D)

f-------~-'<""""""~ PIPE SLEEVE 2"

LARGER I.D. THANPIPE O.D.

HOT VENT DETAIL

Samples from

www.AutoCADDetails.net

Page 38: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

THERMOMETER -­

UNION

3-WAY CONTROL VALVE

AIRVENT --~

WATER COIL

STRAINER

PRESSURE GAUGE

1/2" DRAIN VALVE

(DETAIL)

HOT WATER COIL CONNECTION

BALANCING COCK

RETURN

SUPPLY..

Samples from

www.AutoCADDetails.net

Page 39: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

STRAINER

GATE VALVE

STEAMSUPPLY

MODULATINGMOTOR OPERATOR

~ LOCATE HANGER AT/ LAST ELBOW BEFORE

HUMIDIFIER

DUCT

AIR LINE

SEPERATOR

TRAP STEAM JACKETMAINFOLD

~DRIPLEG

(STEAM)

HUMIDIFIER PIPING DETAIL

Samples from

www.AutoCADDetails.net

Page 40: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

GATE VALVE

t ~~~- CHECK VALVE REQUIRED IFSYSTEM IS PRESSUREIZEDBY OTHER SOURCES

~c:::-- GATE VALVE - N.O.(CLOSE FOR PUMPSUCTION PRESSURE)

1/4"

I---+---~?( PRESSURE GAGE

UNION

CONCENTRIC~

REDUCER

MOTOR

PUMP

CONCENTRIC~REDUCER -

UNION

GATE VALVE

---- BALANCING/SHUT-OFFVALVE WITH PRESSURETAPS

IF PUMP SUCTION ANDDISCHARGE FLANGESARE TAPPED, USE THESEPOINTS FOR PRESSUREGAGE CONNECTIONS

GATE VALVE - N.C.(OPEN FOR PUMP SUCTIONPRESSURE)

INLINE CENTRIFUGAL PUMP

Samples from

www.AutoCADDetails.net

Page 41: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

8' - 0" SPAN------- -------

PLAIN TROLLEY

1,000 LB CAPACITY

JIBCRANE~

l­IC.9WI~«wIII0:::

LiS....Jo=ob.......

'---------- ELECTRIC WIRE ROPE HOIST,1/2 - TON CAPACITY,40 FT. MIN. LIFT, 115 V,

SINGLE PHASE

•~ ELECTRICAL CONTROL PENDANTWITH 15 FT. CABLE MIN.

NOTE:SEE PLAN FOR JIBCRANE LOCATION.

~~3 FT. DIA. BASE,

6 HOLE BOLT PATTERNAT 60 DEGREES.

JIB CRANE DETAIL

Samples from

www.AutoCADDetails.net

Page 42: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

2"VENT-~

r----- ENCLOSUREREFER TO ARCH DWGS

~--\-------L--------+=;-HOT & COLD WATERSUPPLY TO SINK

P-7(1 BOWL SHOWN)

WATER SUPPLYPIPE SUPPORTREFER TO ARCHDRAWINGS __----J

~- 6" COLLECTIONDRAIN ABOVE FLOOR

DOUBLE BOWL TYPE

LAUNDRY SINK DRAIN CONNECTION DETAIL

Samples from

www.AutoCADDetails.net

Page 43: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

I..........--WALL

LAVATORYORSINK 1" CONDENSATE DRAIN

FROM AlC UNITS

~- CHROME PLATEDESCUTCHEON

1" COPPER ELBOW~- COPPER TO INCH

PIPE SIZE

~ 1" COPPER COUPLING

~

1 1/2" 'pi TRAP --~

11/2"TAILPIECE->~:: .. /./1 1/2" X 1 1/2" -----~I

x1"TEE

1 1/2" TRAP ARM --'

LAVATORY TAILPIECE DETAIL

Samples from

www.AutoCADDetails.net

Page 44: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

LAST BRANCH LINEFROM MAIN

,------- GATE VALVE

STRAINER

FLOW

/)

6" MINIMUM

4"MINIMUM

UNION3/4"

F & TTRAP USE200 LBS/HR @ 2 PSI P.O.

DIRT POCKET FULLSIZE OF MAIN

RETURNTO MAIN

LOW PRESSURE DRIP DETAIL

Samples from

www.AutoCADDetails.net

Page 45: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

WEATHERPROOFCAP

METAL FLUE

GUYWIRESIF REQUIREDBY HEIGHT(3 TYPICAL) --------------.,,;

STORM COLLAR

FLASHING

ROOF··~~

«0...LLZ

~O-w/ S u:::w­oOZw«0...0 000::000«oo«z-

METAL FLUE

METAL FLUE STACK DETAIL

Samples from

www.AutoCADDetails.net

Page 46: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

SEE PLANS FORSIZE &CAPACITIESOF UNIT

v~ LINTEL

//~ PROVIDE 1" RIGID INSULATION

/IF UNIT IS LOCATED ONOUTSIDE WALL

D6"tUNLESS NOTED

OTHERWISE-C~ \

RECESSED CONVERTOR DETAIL

Samples from

www.AutoCADDetails.net

Page 47: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

TURN GAGE FACETO ALLOW READING

RELIEF VALVE-SEEDWGS. FOR SIZE ANDCAPACITY

~ PRESSURE GAGE, SEECD DWGS. FOR RANGE

I

r REDUCED PRESSURESTEAM

I-----I--------'------S

>1

7GLOBE VALVE

BYPASS 1 PIPE SIZESMALLER THAN H.P.STEAM, 3/4" MIN.

PRESSURE SENSING LINE

ECCENTRICREDUCER

CD

H.P.STEAM ISTRAINER

PRESSURE REDUCING VALVESEE DWGS. FOR SIZE --------' 10 PIPE DIA. MIN.

SINGLE STEAM PRV STATION

Samples from

www.AutoCADDetails.net

Page 48: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

STEAM MAIN

,------ BUCKET TRAPSEE SCHEDULE

12" MIN. r=\ DIRT LEG (FULL

SIZE OF MAIN)

------s

1 CONDENSATERETURN

(MEDIUM PRESSURE)

STEAM MAIN DRIP DETAIL

Samples from

www.AutoCADDetails.net

Page 49: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

~ ANCHOR SECURELY,--------------, / TO BLDG. CONST.

RELIEF VALVESEE DWGS FOR

SIZE &SETTING 1· ~TO OUTSIDE~ OF BLDG

~ DRIP PAN ELL

SEAT DRAIN

TO FLOOR DRAIN

TO DRAIN

FLOOR Ir------------u--lrc~

STEAM RELIEF VALVE DRIP PAN ELL

Samples from

www.AutoCADDetails.net

Page 50: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

PUMPED X"CONDENSATE RETURN

4"

'--------X" SYSTEM DRAIN VALVEW/HOSE COUPLING(SEE CAT. FOR SIZE)

DESIGNER NOTE:MAX. BOILER WORKINGPRESSURE - 15 PSIG

DESIGNER NOTE:VERIFY CLEARANCESFOR TUBE PULLSPACE EITHER END

,----t----- WATER LEVEL

,------SHORT NIPPLE

rh--+--+- X" EQUALIZER LINE(SEE CAT. FOR SIZE)

,------+-r--+-- REDUCER(IFREQ'D)

------- X" STEAM SUPPLY

_------GATE VALVE (TYP.)

,--------- 15 PSIG A.S.M.E. SAFETY RELIEFVALVE W/DRIP PAN ELBOW &XIX" RELIEF LINE UP THRU ROOF

,-----+-TUBE PULL SPACEh----I-.h

LEFT SIDE

X" STEAM OUTLET

STEAM WATER-TUBEATMOSPHERIC BOILER DETAIL

6" CONCRETE PAD----+_~

THERMOMETER W/SEPARABLE ----------­SOCKET & ADJUSTABLE HINGE

X" DIA. BOILER STACK WIDRAFT HOOD

LOW-WATER CUTOFFWITH FLOAT SWITCH& GAUGE GLASS

REMOVABLEHEAD PLATE

X" CONDENSATE INLET

BLOWDOWN TAPPING

PRESSURE GAUGE -----------,W/GAUGE COCK

X" STEAM HEADER-----~IUNION (UP TO 2-1/2")---_~ ­FLANGE (3" & LARGER)TYPICAL.

DESIGNER NOTE:HAND HOLE OPENINGFOR GROSS OUTPUTOF 1,600,000 BTUH& LARGER

('C

/ \

I \

I---

0 - [S00000000

~0 0

0 0

00 0

~ J, ~00000 00

I

-@-

[ 1I

BOILER FRONT

I I1~~~~Jl~~ i:i~~

Samples from

www.AutoCADDetails.net

Page 51: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

TO DISCONNECT SWITCH

SUBMERSIBLE SUMPPUMP

~UNION

FORCONT. OFPIPING SEEPLUMBING FLOORPLAN

,-- CHECK VALVE

00000000o 0 0 0 0 0000

000000000

FLOAT SWITCH

SUMP PUMP DETAIL

SUMP PIT"X "

Samples from

www.AutoCADDetails.net

Page 52: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

SHEET METALH.V. DUCT

H'- 6'-0" MAX.

FLEX DUCT

REDUCER OR INCREASERIF REQUIRED

MIN. OF 4 DIA. STRAIGHTDUCT AT BOX INLET(NO BENDS)

TERMINALUNIT

\ ~ SHEET METALPLENUM OR BOXINTEGRAL OUTLETS

B.D.--,-I

I

SHEET METAL RUNOUT SIZE ASSHOWN ON PLAN

REDUCER OR INCREASERIF REQUIRED

'-a" MIN.12'-0" MAX.

\CEILING

PROVIDEHANGER

FLEXIBLEDUCT

DIFFUSERNECK SIZE

SUPPLYDIFFUSER REDUCER OR INCREASER

IF REQUIREDHV. DUCT

APPLICABLE FOR DIFFUSERS SERVEDBY ROUND DUCTS ONLY

TERMINAL UNIT DUCT TAKE-OFF

Samples from

www.AutoCADDetails.net

Page 53: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

ACOUSTICAL LINING

;/IY

.Z-~

I-N

2'-MIN.

TRANSFER DUCT DETAIL

Samples from

www.AutoCADDetails.net

Page 54: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

STRUCTURAL TIE SUPPORT--~

BRIDGE GIRDER

CAPACITY 3 TONS

VBRIDGE CRANERUNWAY BEAM

Fi=:::=::rTK====~

INTERLOCKOPERATOR

~LATCHANDFORKS

\--TROLLEY/L,sT

GUIDE ROLLER-- II

MONORAIL~

~-- PENDANT PUSHBUTTON CONTROL

TRANSFER/INTERLOCK MECHANISM

Samples from

www.AutoCADDetails.net

Page 55: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

r--- 3" VENT LINE

~- DOUBLE-WALLED UNDERGROUNDSTORAGE TANK.

~ PROVIDE SPILL CONTAINERWITH RETURN TO TANK

------ 4" STORAGE TANK FILL

~GAGEHATCH

/

~_I--_'~ ACCESS MANHOLE

/

~1"DAYTANKRETURN

I !1"DAYTANK 7SUPPLY-

BOILER

_\

DAYTANK\3/4" BOILERSUPPLY

~===ll,--------

~=:;::3------j

3/4" BOILER /RETURN~

TYP. BOILER FUEL OIL FLOW SCHEMATIC

Samples from

www.AutoCADDetails.net

Page 56: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

ER (BD.)DON

D-3/4 D HEEL R

~-- BRANCH DUCT1--/-\-/-\-/- BALANCING DAMPER (BD.)

WHERE INDICATED ONDRAWING

MAIN DUCT~

(45 0

Co~ ~

~ BRANCH DUCTpSi

/\/\/ BALANCING DAMPWHERE INDICATE

A DRAWINGV

J ~ MAIN DUCT I"

~-S-T-RA-IG-H-T--~~--~--------~3/4 D THROATRADIUS

MAY BE USED ANYWHERE

USE ONLY AT LAST TAKEOFF BEFORE OUTLETS &THEN ONLY WHERE RECTANGULAR RUNOUTS AREINDICATED ON DRAWINGS

MAIN DUCT

45 0

RECTANGULAR

ROUND

I----_~ BRANCH DUCT

BALANCING DAMPER (BD.)WHERE INDICATED ON

DRAWING

USE ONLY AT LAST TAKEOFF BEFORE OUTLETS &THEN ONLY WHERE ROUND RUNOUTS AREINDICATED ON DRAWINGS

TYPICAL BRANCH CONNECTION

Samples from

www.AutoCADDetails.net

Page 57: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

r--- MAKE BRANCHCONNECTION ATTOP OF MAIN

~ COMPRESSORAIR MAIN

/'--- SUPPORT ASREQUIRED

QUICK-CONNECTHOSE COUPLING

........~ BALL VALVE (ORGATE VALVE)

o_I

V

DRIP LEG WITH BALLVALVE (OR GATE VALVE)

FLOOR

TYPICAL COMPRESSED AIR DROP

Samples from

www.AutoCADDetails.net

Page 58: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

MAKE BRANCHCONNECTION ATTOP OF MAIN

COMPRESSEDAIR MAIN

SUPPORT AS REQ1D.

- STRAINER

PRV W/PRESSUREGAUGE WHERE REQ'D.

rLUBRICATOR

/

- QUICK-CONNECTHOSE COUPLING

\ l) BALL VALVE (ORGATE VALVE)

DRIP LEG WITH BALLVALVE (OR GATE VALVE)

o_I

~

~FLOOR----'--------------'-----~------------""""""--

TYP COMP AIR TOOL STATION

Samples from

www.AutoCADDetails.net

Page 59: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

WALL OR PARTITION--------~~"

~----1/8" ANGLE TO FIT

'---j-- DUCT

14 GA. SLEEVE --+----~PAINTED RED

FIRE DAMPER --+----------- ~-+---14GA. SLEEVEPAINTED RED

DAMPER ACCESS~PANEL. LOCATEDON CORRIDOR SIDEPAINTED RED

(9" MAX.) /(2" MIN.)

~-----1 1/2"x1 1/2"x1/8" ANGLEON ALL 4 SIDES

TYPICAL FIRE DAMPER

Samples from

www.AutoCADDetails.net

Page 60: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

COMBINATION FIRE/SMOKEDAMPER, WELD OR BOLTTO SLEEVE

~---+----14GA. SLEEVEPAINTED RED

~-+---- NEW HINGED FIRE DAMPERACCESS PANEL. LOCATEDON CORRIDOR SIDE. PAINTED

------------1 1/2"x1 1/2"x1/8" ANGLEON ALL 4 SIDES

ACCESSIBLE CEILING(2"MIN.)(9"MAX.)

~~------1/8"ANGLE TO FIT

r======~~~§~~~~~~=~~-~==== ~--OPERATORIACTUATORI PNEUMATIC

SEALANT: DOW ------j--------<

CORNING 999

EXISTING WALL ------------------1'

14 GA. SLEEVE ------f-----______..

PAINTED RED

14 GA. SLEEVE ------f--------~PAINTED RED

EXISTINGDUCT~

TYPICAL FIRE/SMOKE DAMPER

Samples from

www.AutoCADDetails.net

Page 61: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

ROOFING

o 0

BOLTS

REFER ARCHITECTURAL DRAWINGSFOR ROOF PENETRATION DETAILS -------l

ANGLE IRON

--r-r;::::'==-------'~========~

~- ELECTRIC AUTOMATICVENT DAMPER

DRIPLEG

r-----t'--- GAS VALVE

~ISOLATION

VALVEGAS PIPING (REFERHVAC PLAN FOR SIZES)

UNITHEATER

HANGER RODS -~

ADJUSTABLEHORIZONTALAND VERTICAL

LOUVERS· \

TYPICAL GAS FIRED UNIT HEATER DETAIL

Samples from

www.AutoCADDetails.net

Page 62: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

o 0

......------INSULATING UNION

~ TEE W/BUSHINGY AND 3/8" PLUG

~ GAS PRESSURE/ REGULATORo

PLUGGED TEE WIBUSHINGAND 3/8" PLUG

GAS COCK(TYP.)

~/ .ANNODELESS RISER

BUTT WELDEDSERVICE TEE

-1 r~~

1 1 1 1

TO BUILDINGSUPPLY-~

FINISHED

GRADE _~---.------.--------=T-------.-----c.-=---.---------.--

CAST IRON EXTENSIONTYPE SERVICE BOX ------+-~

(POLY)SERVICE SHUT-OFF ~

VALVE W/2" SQ. OPERATING NUT -----------

SWING JOINT OUTLET ---

/\

HOT TAP VALVE -------"

GAS MAIN, 10-45 PSIG ---

4" CONCRETE PAD-~

NOTE: LINE SIZES AS CALLED FOR ON SITE PLAN

TYPICAL GAS SERVICE CONNECTION DETAIL

Samples from

www.AutoCADDetails.net

Page 63: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

-

l-

I

INSULATING UNION

BUTT WELDEDSERVICE TEE

~I:'~i '

-----'-

- TEE W/BUSHINGAND 3/8" PLUG

- GAS PRESSUREREGULATOR

PLUGGED TEE W/BUSHINGAND 3/8" PLUG

/ - GAS COCK(TYP.)

- ANNODELESS RISER

~ BY-PASS(REFER TABLE)

(POLY)SERVICE SHUT-OFF /:/VALVE W/2" SQ. OPERATING NUT

SWING JOINT OUTLET

HOT TAP VALVE /1f'GAS MAIN, 10-45 PSIG - /

CAST IRON EXTENSIONTYPE SERVICE BOX---4" CONCRETE PAD

TO BUILDINGSUPPLY ~

i

GAS METER DATA BY BUILDING

BLDG.BY-PASS STD. CU. REG. CAP.LINE SIZE FT.lHR. (CFH)

DORMITORY BUILDINGS 3" 3,900 4,485

ADMINISTRATION BUILDING 3" 5,495 6,295

NOTE: LINE SIZES AS CALLED FOR ON SITE PLAN

TYPICAL GAS SERVICE (W/BY-PASS) DETAIL

Samples from

www.AutoCADDetails.net

Page 64: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

OUTSIDE AIR~-~~VENT COMPLETE

WITH BIRDSCREENGALV. CURB

CAP~.

1/4" MANUAL "'.~AIR VENT ,-------c-----_____=___,

FOR FLASHING ANDROOF DETAILS SEEARCHITECTURAL DWGS.

-lAIRSTREAMTHERMOSTAT

HWR(~<1? [

~t~N~~~~LVE\ ~======o=\(:~~t/'~~~~HWS ) ~l I I ~=====i1~~~ ~~~~~ 1----------1 f--- ~~~ ~~~

GATEVALVE

4-WAY DIFFUSER

TYPICAL MAKE-UP AIR UNIT DETAIL

Samples from

www.AutoCADDetails.net

Page 65: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

- RELIEF VENT

~ '- BIRDSCREENir==~========~-~~

~ rROOF

)PREFAB CURB,FURNNISHED BYVENT MFR. ~;

DUCT & DAMPER-FULLSIZE OF CURB OPENING

~ ACCESS PANEL 6" X 6"-----,-----~ ~-~~~~ TO DAMPER

COUNTER BALANCEDBACKDRAFT DAMPER

PAINT INSIDE BOTTOM& UP 12" ON SIDES OFDUCT W/BITUMASTICPAINT

SEE PLANS FOR DUCT SIZES& ARRANGEMENTS

(WITH DUCT WORK)

TYPICAL RELIEF VENT DETAIL

Samples from

www.AutoCADDetails.net

Page 66: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

RELIEF VENT

PREFAB CURB, ) BIRDSCREENFURNISHED BYVENT MFR. ~~ (ROOF

~~~~c=:=:

2" DEEP SHEET METAL DRIP PAN SUSPENDED FROMROOF DECK-6" LARGER THAN ROOF OPENING (3" EACHSIDE). COAT INSIDE OF PAN W/BITUMASTIC PAINT.

STRAP HANGER

COUNTER BALANCEDBACKDRAFT DAMPER,FULL SIZE OF CURBOPENING, MOUNT ATBOTTOM OF ROOFDECK -----~

EXHAUSTAIR

~12" OR 1/2 DIMENSIONOF ROOF OPENING­WHICHEVER IS GREATER

TYPICAL RELIEF VENT DETAIL

Samples from

www.AutoCADDetails.net

Page 67: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

UNIONSUPPLY & RETURN ---,

RUNOUTS TO MAINS

~--+-,-+--------j I

3/4"HOSE~;? JEND DRAIN VALVE

UNION

~

GATE VALVEIMOTOR

HOT WATER SUPPLY-~

AIR

~FLOW

UNIT HEATER WITH PIPING

Samples from

www.AutoCADDetails.net

Page 68: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

"C rc14---- 3/4"

DHW CLOTHES WASHERWALL BOX

~-++-1"

DCW

2"=I----WASTE

3/4" COMBINATIONSWEAT CONNECTION -+-+----+-+------+-----1===== I_---+==+------+=~-------l

1" COMBINATION ----+--i-----+-t----------+-T--',-T

SWEAT CONNECTION

:=In----rrL 'n-J---+----------rrl~42"

,= l ,=.TIJ1+--------f/-ITll JTII-----+-------rrl

=~ACCESSPANEL

/

1FLOORLINE

----------------------

WATER~HAMMER

ARRESTOR

UTILITY WALL BOX FOR CLOTHES WASHER

Samples from

www.AutoCADDetails.net

Page 69: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

HOT WATER SUPPLY

TEMPERATURE RELIEFVALVE

TO FLOOR DRAIN

COLDWATERSUPPLY

TEMPERATURE REGULATING

THERMOMETER~

VALVE (HR.)

STRAINERST MLINE

OFFSET FOR TUBEBUNDLE REMOVAL~

STRAINER "-

-11~r--------i111

rF&T TRAP (HR.)

TO CONDENSATERECEIVER

SCALEPOCKET

HOT WATERRETURN

/H.W. CilRCULATINGPUMP (G.P.M. HD.)

PRESSURE RELIEFVALVE

GAL. STORAGEG.P.H. RECOVERY BASE

ON 100D TEMP. RISEFROM 40D TO 140D

VERTICAL HOT WATERGENERATOR CONNECTIONS

Samples from

www.AutoCADDetails.net

Page 70: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

NEOPRENEPAD

EQUIPMENT

STEEL SPRINGVIBRATIONISOLATOR

NEOPRENEPAD

VIBRATION ISOLATOR DETAIL

5/8" 0 A.B.

CONCRETEFLOOR

Samples from

www.AutoCADDetails.net

Page 71: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

MAY EXTEND ASWASTE OR VENT -----+--L

FOR WALL CONST.~

SEE DRAWINGS

C.I. CLEANOUT TEE -------+--+----

CLEANOUTPLUG

COUNTERSUNKSCREW

POLISHED S.S.ACCESS COVER

WASTE LINELENGTH TO SUIT~PI ~ 1/8" BEND AND END

/ Y OF LINE CLEANOUT

/ WASTE LINE

FLOW

WALL CLEANOUT-FINISHED ROOMS

Samples from

www.AutoCADDetails.net

Page 72: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

3/4" HW SUPPLY

~ 3/4" CW MAKE UP~

'----- VACUUM RELIEF VALVE

~-----GATEVALVE

COMBINATION TEMPERATUREAND PRESSURE RELIEFVALVE -------

DRAIN TO EXTERIOROF BUILDING ------------1..~1

~-DIP TUBE INSIDEOF TANK

~- 3/4" PLYWOOD

...--"-----1- 2"x 2"x 1/8"ANGLE(2 BRACKETS REQ'D.)

~-- ELECTRIC WATERHEATER

~HOSEBIBB

2'-0"

~h~:::::===~'===~~~51----1/4"NUT ANDBOLT, TYPICAL

WALL--~

HEATINGELEMENT ----j------

AQUASTAT ---+------+--~

---------h'-------+- 1/2" ANCHOR BOLT OREXPANSION BOLT (2 PERBRACKET)

NOTE TO DESIGNER: N.S.P.C. 10.16.7 REQUIRES: WHERE A HOTWATER STORAGE TANK OR INDIRECT WATER HEATER IS LOCATEDAT AN ELEVATION ABOVE THE FIXTURE OUTLETS IN THE SYSTEM AVACUUM RELIEF VALVE SHALL BE INSTALLED ON THE STORAGE TANK.

WALL MOUNTEDELECTRIC WATER HEATER DETAIL

Samples from

www.AutoCADDetails.net

Page 73: Mechanical CAD Details - AutoCAD, Construction · PDF fileair-cooledchiller piping connection detail samples from . aquastat l-combination pressure and temperature gage l multi purpose

VACUUM BREAKER--~

COLD WATER LINE --~

TEMP.lPRESS. RELIEF --------1

VALVE

(l~ HOT WATER LINEX

.J.w=-_--l-----=:O"'~-----=~- 01 ELECTRIC UNIONS

FOR CAPACITY SEE ------­WATER HEATERSCHEDULE

FULL SIZE RELIEFPIPE TO DRAIN

DRAIN VALVE

/AIRGAP

~

~~~FLOOR DRAIN

~

WATER HEATER DETAIL

Samples from

www.AutoCADDetails.net