Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks. Prepared by: Shah Faisal Iqbal. Outline. Motivation What is Fatigue??? Proposed protocol Placement of nodes Scenarios Energy analysis Radio model parameters Transmission model Simulations and results Comparison table - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/1.jpg)
Measuring Fatigue of Soldiers in Wireless Body
Area Sensor Networks
Prepared by: Shah Faisal Iqbal
![Page 2: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/2.jpg)
Motivation What is Fatigue??? Proposed protocol Placement of nodes Scenarios Energy analysis Radio model parameters Transmission model Simulations and results Comparison table conclusion
Outline
![Page 3: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/3.jpg)
Wireless Body Area Sensor Networks (WBASNs) consist of on-body and in-body sensors on human body for monitoring health.
In WBASNs protocols are concerned with energy efficiency.
Specific mobility scenarios are not considered in previous protocols.
Motivation
![Page 4: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/4.jpg)
Fatigue, physical or mental, is a subjective feeling of tiredness.
Physical fatigue is the inability of muscles to maintain optimal physical performance.
Fatigue is caused by loaded work, depression, boredom, mental stress, lack of sleep, etc.
What is fatigue???
![Page 5: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/5.jpg)
For improvement of security, we must know the physical status of soldiers.
An important factor in physical status of soldier is fatigue.
If we know state of fatigue in soldier then we can send backup to them.
We propose a protocol for measuring fatigue of soldier.
Proposed protocol
![Page 6: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/6.jpg)
Four sensors are attached on body of soldiers• Temperature sensor• Blood glucose level sensor• Heartbeat sensor• Base station
Placement of nodes
![Page 7: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/7.jpg)
Temperature sensor is placed on finger tip to measure temperature.
Blood glucose level sensor is also positioned on finger tip to measure glucose level in blood. • We assume that sensor takes blood samples
periodically and checks glucose level in blood.
Heartbeat sensor is placed on heart to measure heartbeat.
BS is placed on wrist of soldier, all the above three sensors send their data to BS.
Cont…
![Page 8: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/8.jpg)
Cont… Placement of nodes on soldiers body.
![Page 9: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/9.jpg)
We take three scenarios for measuring fatigue of soldier.◦ Walking (3.0 miles per hour)◦ Slow running (5.0 miles per hour)◦ Fast running (7.0 miles per hour)
In all the three scenarios, sensors sense the heartbeat, glucose level and temperature and send their data to BS.
Scenarios
![Page 10: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/10.jpg)
For state of fatigue we use harris benedict formula. i.e.
BMR is the amount of energy required to maintain metabolic rate of body.
If soldier’s condition meets this level then this is called as state of fatigue.
Cont…
![Page 11: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/11.jpg)
Energy consumption model used in paper is summarized in the following equations.
Where:Etx= transmission energy
Erx=Reception energy
Energy analysis
![Page 12: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/12.jpg)
ERXelec=Energy dissipated by radio to run circuitry for receiver
ETXelec=Energy dissipated by radio to run the circuitry for transmitter
Eamp =Amplification energy
n=Path loss exponent
K=Number of transmitted bits
Cont…
![Page 13: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/13.jpg)
Following are the parameters of radio model
Radio model parameters
![Page 14: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/14.jpg)
Figure shows sending of data from nodes to BS(server)
Transmission of data
![Page 15: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/15.jpg)
We used MATLAB for simulation.
Our goals in conducting simulation are,◦ Measuring fatigue of soldier while walking,
running slowly and running very fast.◦ Extension of sensor lifetime.
Simulation and results
![Page 16: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/16.jpg)
From figure we can see that lifetime of sensors is more in walking scenario, because of less activities and sensor does not send data more often.
Life of sensor
![Page 17: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/17.jpg)
Throughput of running scenario is higher then walking and slow running scenario because heartbeat increases faster and sensor has to send data.
Throughput
![Page 18: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/18.jpg)
For measuring fatigue, we set a threshold by harris benedict formula.
1500 (joules) is set to be threshold in our simulations.
Figure in next slide shows the fatigue of soldier.
Fatigue
![Page 19: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/19.jpg)
When soldier is walking state of fatigue comes later compared with slow and fast running scenarios because of soldiers activity.
Cont…
![Page 20: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/20.jpg)
In fast running scenario sensors drain off their energy quickly than walking and slow running scenario, as they are busy in getting data from soldiers body.
Sensor’s residual energy
![Page 21: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/21.jpg)
Comparison table of lifetime and throughput for three scenarios.
Comparison table
![Page 22: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/22.jpg)
Table shows the fatigue of soldier in rounds.
When soldier is walking his state of fatigue in the 10182th round.
Table
![Page 23: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/23.jpg)
Routing protocol for measuring fatigue of soldier.
Performs better in terms of sensor lifetime and throughput.
conclusion
![Page 24: Measuring Fatigue of Soldiers in Wireless Body Area Sensor Networks](https://reader035.vdocuments.us/reader035/viewer/2022062310/568166b2550346895ddab0e2/html5/thumbnails/24.jpg)
Any Question ???
Thank you