Measurements overview
• Glass transmittance - Lab 6
• Glass signal shape - MT6
• Glass light yield and attenuation - CDF
• Crystal acquisition with Paul’s card - Sidet
![Page 3: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/3.jpg)
Glass transmittance
• Thanks to people at Lab 6 (Anna, Irina)
• Using spectrophotometer HP8452 (wavelength 190 to 820 nm, 2 nm step)
![Page 4: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/4.jpg)
Glass transmittance
glass transmittance
0
10
20
30
40
50
60
70
80
90
100
190 290 390 490 590 690 790
wavelength (nm)
transmittance (%)
glass 3
glass 2
![Page 5: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/5.jpg)
Glass signal shape
• Set the glass vertically, with two trigger scintillators selecting cosmics around the vertical
• One PM only on one end of the glass• One measurement with the PM in the down
position (106 events collected), Cherenkov light collection is favored
• One in the up position (107 events collected), Cherenkov light collection is disfavored
![Page 6: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/6.jpg)
Glass signal shape
PMT Down
NT2
NT1
PMT Up
NT2
NT1
![Page 7: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/7.jpg)
Glass signal shapeGlass #2, PM down & up
-0,45
-0,4
-0,35
-0,3
-0,25
-0,2
-0,15
-0,1
-0,05
0
0,05
-5,00E-08 0,00E+00 5,00E-08 1,00E-07 1,50E-07 2,00E-07 2,50E-07 3,00E-07
time (s)
amplitude (mV)
PM down
PM up
![Page 8: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/8.jpg)
Glass light yield and attenuation
• Thanks to Davit Chokheli for assistance using CDF muon scintillator test bench
• Two PMs, one on each end of the glass• First calibrate the PMs with an LED, useful to
have the absolute light yield• Then measure the number of photons collected
by the PMs when the trigger is moved along the glass length
• Two trigger scintillators 12 cm wide• Five positions
![Page 9: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/9.jpg)
Glass light yield and attenuation
PM2 PM1
Top trigger scintillator
Bottom trigger scintillator
0”36”
![Page 10: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/10.jpg)
Glass light yield and attenuationlight attenuation - glass #2
0
5
10
15
20
25
30
35
0 6 12 18 24 30 36
distance from PM (inches)
# of pe
PM1
PM2
![Page 11: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/11.jpg)
Glass light yield and attenuationlight attenuation - glass #2
y = 24,701e -0,0543x
y = 39,864e -0,0537x
1
10
100
0 6 12 18 24 30 36
distance from PM (inches)
# of pe
PM1
PM2
Attenuation length: about 47 cm
![Page 12: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/12.jpg)
Crystal acquisition & Paul’s card
• Thanks to Paul for assistance and patience• Set a BGO crystal between two trigger
scintillators• The scintillators coincidence gives the trigger
for the card• The BGO signal goes into card channel 2,
some 6X attenuation necessary to cope with saturation
• Calibrated the channel, to have physical units
![Page 13: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/13.jpg)
T2
Crystal acquisition & Paul’s card
TriggerSignal into Ch 2
BGO
T6
DISC COINC
Paul’s card
NIM->TTL
SCALER
![Page 14: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/14.jpg)
Crystal acquisition & Paul’s cardBGO signals - 6X attenuation
-3,00E+01
-2,50E+01
-2,00E+01
-1,50E+01
-1,00E+01
-5,00E+00
0,00E+004,71E-096,59E-081,27E-071,88E-072,50E-073,11E-073,72E-074,33E-074,94E-075,56E-076,17E-076,78E-077,39E-078,00E-078,62E-079,23E-079,84E-071,05E-061,11E-061,17E-06
time (s)
amplitude (mV)
ev 1
ev 2
ev 4
ev 5
ev 6
ev 7
ev 12
• Saturation still visible for larger signals
• Cherenkov-only events?
![Page 15: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/15.jpg)
Crystal acquisition & Paul’s cardBGO signals - 6X attenuation
-3,00E+01
-2,50E+01
-2,00E+01
-1,50E+01
-1,00E+01
-5,00E+00
0,00E+004,71E-096,59E-081,27E-071,88E-072,50E-073,11E-073,72E-074,33E-074,94E-075,56E-076,17E-076,78E-077,39E-078,00E-078,62E-079,23E-079,84E-071,05E-061,11E-061,17E-06
time (s)
amplitude (mV)
ev 2
ev 12
![Page 16: Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab](https://reader036.vdocuments.us/reader036/viewer/2022081603/56649e4f5503460f94b47182/html5/thumbnails/16.jpg)
Future plans
• Do previous measurements on more glasses
• Finalize remote acquisition for Tektronix scope
• Attach two SiPM on the crystal and acquire with Paul’s card
• Finalize Udine frame to support crystal setup