measure the high-order harmonic voltage and current of ... · power quality analyzer pw3198-90 (pc...

1
Measure the High-Order Harmonic Voltage and Current of Power Lines Measure RMS values and waveforms of high-order harmonic voltage and current that may cause a malfunction and failure of the equipment connected to the power line. Power Service, Maintenance Products used S0028-E00 March 2011 Information valid as of March 2011. Specifications are subject to change and revision without notice. POWER QUALITY ANALYZER PW3198 Detect an event when the RMS value of harmonics from which the fundamental is removed at intervals of 200 ms exceeds the set threshold value. Display the RMS values of high-order harmonic along with the maximum RMS value during the period of occurrence of the event, as well as the period of time from when the event occurs to when it ends. Harmonic components can be measured in the wide frequency range from 2 kHz to 80 kHz. Save event waveforms and high-order harmonic waveforms. For a multi-phase system, the individual phases can be measured independently. Resonance Breakdown or Bungle Inverter equipment PW3198 Measurement example Clamp-on sensor is optional. You may choose from selections below : 9694(AC 5A), 9660(AC 100A), 9661(AC 500A), 9669(AC 100A), 9667(AC 500A/5000A), 9657-10(AC 10A), 9675(AC 10A), 9695-02(AC 50A), 9695-03(AC 100A) Highlights High-Order Harmonic Current Wavefom High-Order Harmonic Current Wavefom POWER QUALITY ANALYZER PW3198-90 (PC Application software 9624-50 included)

Upload: others

Post on 14-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Measure the High-Order Harmonic Voltage and Current of ... · POWER QUALITY ANALYZER PW3198-90 (PC Application software 9624-50 included) Title: S0028-E00 Author: shibata Created

Measure the High-Order Harmonic Voltage and Current of Power Lines

Measure RMS values and waveforms of high-order harmonic voltage and current that may cause a malfunction and failure of the equipment connected to the power line.

Power Service, Maintenance

Products used

S0028-E00March 2011

Information valid as of March 2011.Specifications are subject to change and revision without notice.

POWER QUALITY ANALYZER PW3198

・ Detect an event when the RMS value of harmonics from which the fundamental is removed at intervals of 200 ms exceeds the set threshold value.・ Display the RMS values of high-order harmonic along with the maximum RMS value during the period of occurrence of the event, as well as the period of time from when the event occurs to when it ends.

・ Harmonic components can be measured in the wide frequency range from 2 kHz to 80 kHz.・ Save event waveforms and high-order harmonic waveforms.

・ For a multi-phase system, the individual phases can be measured independently.

Resonance

Breakdownor

Bungle

Inverter equipment

PW3198

Measurement example

Clamp-on sensor is optional.You may choose from selections below : 9694(AC 5A), 9660(AC 100A), 9661(AC 500A), 9669(AC 100A), 9667(AC 500A/5000A), 9657-10(AC 10A), 9675(AC 10A), 9695-02(AC 50A), 9695-03(AC 100A)

Highlights

High-Order Harmonic Current Wavefom

High-Order Harmonic Current Wavefom

POWER QUALITY ANALYZER PW3198-90(PC Application software 9624-50 included)