mcpa datasheet

3
GSM900 Base Station Power Amplifier TC-9100 Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com IRMCI Issued:28Oct11 Control: 0-0-0 1/3 Features High downlink power of 55dBm for extended cell coverage. MCPA with 20MHz Instantaneous Bandwidth can support multiple downlink carriers. Low noise amplifier reduces uplink system noise figure and results in reduced call drops and improved voice quality. Reduces handset output power and improved BTS uplink receiver sensitivity. Permits local monitoring via PC at tower bottom and remotely by wireless modem. Alarms can be transmitted to OMC via data link or SMS. Automatic bypass feature permits BTS operation when booster or power supply fails. Internal Li-ion backup battery ensures alarm messages are transmitted when power is down. Designed for all outdoor installationwaterproof, damp-proof and omni-sealed (IP54) Product Description TC-9100 GSM900 band-selective Base Station Power Amplifier provides both uplink and downlink amplification for multiple carriers and extends the coverage that decreases the cost and improves the service quality. The unit is fit for outdoor installation and can boost the transmitted power to extend cell coverage. The uplink low-noise amplifier (LNA) serves to improve the receiver sensitivity of the BTS to cope with the extended cell coverage in the downlink. The unit is powered by both AC and DC power supply options, including 110/220VAC and -48VDC. It consists of duplexers (DPX), uplink LNA, downlink MCPA, RF by-pass switch, Main Control Unit (MCU), distribution board, power supply unit (PSU), wireless modem and Li-ion backup battery. Parameter settings can be done locally via a PC with installed OMT software, or remotely via wireless modem using OMT or OMC software. Through the wireless modem, the alarm data can be transmitted to the OMC automatically, or be sent as SMS to a predefined cellular device. Functional Block Diagram

Upload: ali-samari

Post on 08-Nov-2014

22 views

Category:

Documents


4 download

DESCRIPTION

MCPA

TRANSCRIPT

Page 1: MCPA Datasheet

GSM900 Base Station Power Amplifier TC-9100

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

IRMCI

Issued:28Oct11 Control: 0-0-0

1/3

Features

High downlink power of 55dBm for extended cell coverage.

MCPA with 20MHz Instantaneous Bandwidth can support multiple downlink

carriers.

Low noise amplifier reduces uplink system noise figure and results in reduced

call drops and improved voice quality.

Reduces handset output power and improved BTS uplink receiver sensitivity.

Permits local monitoring via PC at tower bottom and remotely by wireless

modem.

Alarms can be transmitted to OMC via data link or SMS.

Automatic bypass feature permits BTS operation when booster or power supply

fails.

Internal Li-ion backup battery ensures alarm messages are transmitted when

power is down.

Designed for all outdoor installation– waterproof, damp-proof and omni-sealed

(IP54)

Product Description

TC-9100 GSM900 band-selective Base Station Power Amplifier provides both uplink and downlink amplification for

multiple carriers and extends the coverage that decreases the cost and improves the service quality. The unit is fit for

outdoor installation and can boost the transmitted power to extend cell coverage. The uplink low-noise amplifier (LNA)

serves to improve the receiver sensitivity of the BTS to cope with the extended cell coverage in the downlink.

The unit is powered by both AC and DC power supply options, including 110/220VAC and -48VDC. It consists of duplexers

(DPX), uplink LNA, downlink MCPA, RF by-pass switch, Main Control Unit (MCU), distribution board, power supply unit

(PSU), wireless modem and Li-ion backup battery. Parameter settings can be done locally via a PC with installed OMT

software, or remotely via wireless modem using OMT or OMC software. Through the wireless modem, the alarm data can

be transmitted to the OMC automatically, or be sent as SMS to a predefined cellular device.

Functional Block Diagram

Page 2: MCPA Datasheet

GSM900 Base Station Power Amplifier TC-9100

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

IRMCI

Issued:28Oct11 Control: 0-0-0

2/3

Technical Specifications

Electrical Frequency Range, Uplink MHz 895 – 915

Frequency Range, Downlink MHz 940 – 960

Instantaneous Bandwidth MHz 20

Numbers of MCPA 2

Total Output Power dBm 55± 1

Maximum Uplink Gain dB 11 ± 1

Maximum Downlink Gain dB 15 ± 1

Intermodulation, Downlink dBc -58

Spurious 9KHz to 1GHz dBc -70 /30KHz

1GHz to 12.75GHz dBm -30 /1MHz

Noise Figure, Uplink dB 2.5

Absolute Maximum RF Input Power, Uplink dBm +10

Absolute Maximum RF Input Power, Downlink dBm +46

Insertion Loss, By-pass Mode dB 1.5

Pass Band Ripple, p-p dB 2.0

System Group Delay nsec 5000

Input VSWR 1.5

Impedance Ω 50

Power, Mechanical & Environmental

Dimensions, H x W x D mm 668×306×620

Weight (approx.) kg 70

Power Supply (Options) VAC 100 – 240 / 47 – 63Hz

VDC -48

AC Power Consumption (approx.) W 1400

Power Up Waiting Time (approx.) sec 180

MCU Battery Backup Time (approx.) hr 2

Enclosure Cooling Fan

RF Connectors Din-F

Operating Temperature °C -25 to +50

Operating Humidity % 95

EMC ETSI EN 301 489-1

Environmental Class IP54

MTBF hr > 50,000

Note: Typical specification at room temperature

Page 3: MCPA Datasheet

GSM900 Base Station Power Amplifier TC-9100

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

IRMCI

Issued:28Oct11 Control: 0-0-0

3/3

Operation and Maintenance

Using a direct serial connection to a PC, installation and commissioning of the TC-9100 is accomplished by the OMT. Using

the integrated wireless modem (data or SMS mode), equipment parameters can be monitored and controlled remotely.

Controlled equipment parameters include: UL/DL ATT, Soft ON/OFF, Over-Temp Threshold, DL Output Power Threshold,

DL Input Power Threshold and Alarm Report Enable.

Monitored equipment alarms and parameters include: Alarms (LNA, DL PA, Power Down, PSU Fault, DL Input Power Low,

DL Output Power Low, Over Temp), UL/DL Gain, DL Input /Output Power.

The TC-9100 has been developed to take advantage of advanced network operation, where the OMC (optional) provides an

effective solution for central monitoring of a group of Comba products.

Outline Drawing

668

620 306