MARSEILLE (MRS2) LOCATION Enceinte Portuaire, Porte 4, Bâtiment MRS2, 13015 Marseille Fact sheet Colocate your IT infrastructure at the heart of the content hub At a glance Direct access to 13 submarine cables to Africa, the Middle East and Asia Access to 130+ connectivity providers and to France-IX, DE-CIX, NL-ix and NetIX 4,300 m 2 of maximum equipable space Security staff on site 24x7, 365 16 MW grid connection Advanced fire detection and suppression systems 2011 ASHRAE-standard temperature and humidity SLAs Facility 4,300 m 2 of maximum equipable space Located in the immediate vicinity of A55 highway Less than one minute walk from the bus stop 2N redundant design architecture allowing maintenance operations with no service interruption Interconnection Dual-entry fibre into the building Access to more than 130 connectivity providers Direct access to France-IX, DE-CIX NL-ix and NetIX Internet exchanges Direct access to submarine cables to Africa, the Middle East and Asia Access to IP single homing or multi-homing on demand Services Cabinets, Cages and Private Rooms Remote Hands and Eyes: 24x7, 365 Full range of Interxion connectivity Cloud Connect: establish private connections to multiple clouds Extendable to more than 45 data centres across Europe via a single service contract Power 16 MW grid connection High-density power configurations up to 2 kW/m 2 Up to 99.999% availability SLA Hexaload UPS redundancy N+1 backup generators, supporting 48 hours autonomy at full capacity Full range of AC and DC output currents Our MRS2 data centre, opened in 2016, provides the latest secure, scalable infrastructure for mission-critical IT systems, with a wide range of connectivity solutions. Located in the immediate vicinity of A55 highway, MRS2 offers Hexaload UPS power and N+1 cooling, as well as alarm and monitoring systems.

Upload: others

Post on 08-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MARSEILLE (MRS2) - Interxion · 2019-12-20 · MARSEILLE (MRS2) LOCATION Enceinte Portuaire, Porte 4, Bâtiment MRS2, 13015 Marseille Fact sheet Colocate your IT infrastructure at

MARSEILLE (MRS2)

LOCATIONEnceinte Portuaire, Porte 4, Bâtiment MRS2, 13015 Marseille

Fact sheet

Colocate your IT infrastructure at the heart of the content hub

At a glance

■ Direct access to 13 submarine cables to Africa, the Middle East and Asia

■ Access to 130+ connectivity providers and to France-IX, DE-CIX, NL-ix and NetIX

■ 4,300 m2 of maximum equipable space

■ Security staff on site 24x7, 365

■ 16 MW grid connection

■ Advanced fire detection and suppression systems

■ 2011 ASHRAE-standard temperature and humidity SLAs

Facility ■ 4,300 m2 of maximum equipable

space

■ Located in the immediate vicinity of A55 highway

■ Less than one minute walk from the bus stop

■ 2N redundant design architecture allowing maintenance operations with no service interruption

Interconnection ■ Dual-entry fibre into the building

■ Access to more than 130 connectivity providers

■ Direct access to France-IX, DE-CIX NL-ix and NetIX Internet exchanges

■ Direct access to submarine cables to Africa, the Middle East and Asia

■ Access to IP single homing or multi-homing on demand

Services ■ Cabinets, Cages and Private Rooms

■ Remote Hands and Eyes: 24x7, 365

■ Full range of Interxion connectivity

■ Cloud Connect: establish private connections to multiple clouds

■ Extendable to more than 45 data centres across Europe via a single service contract

Power ■ 16 MW grid connection

■ High-density power configurations up to 2 kW/m2

■ Up to 99.999% availability SLA

■ Hexaload UPS redundancy

■ N+1 backup generators, supporting 48 hours autonomy at full capacity

■ Full range of AC and DC output currents

Our MRS2 data centre, opened in 2016, provides the latest secure, scalable infrastructure for mission-critical IT systems, with a wide range of connectivity solutions. Located in the immediate vicinity of A55 highway, MRS2 offers Hexaload UPS power and N+1 cooling, as well as alarm and monitoring systems.

Page 2: MARSEILLE (MRS2) - Interxion · 2019-12-20 · MARSEILLE (MRS2) LOCATION Enceinte Portuaire, Porte 4, Bâtiment MRS2, 13015 Marseille Fact sheet Colocate your IT infrastructure at

[email protected]

Cofounder: Uptime Institute EMEA chapter. Founding member: European Data Centre Association. Patron: European Internet Exchange Association. Member: The Green Grid, with role on Advisory Council and Technical Committee. Contributor: EC Joint Research Centre on Sustainability. Member: EuroCloud.

Interxion is compliant with the internationally recognised ISO/IEC 27001 (537141) certification for Information Security Management and ISO 22301 (BCMS 560099) for Business Continuity Management across all our European operations. © Copyright 2017 Interxion. DC-GEN-HQ-MRS2-FR-eng-11/17

International HeadquartersMain: + 44 207 375 7070Email: [email protected]

European Customer Service Centre (ECSC)Toll free Europe: + 800 00 999 222 / Toll free US: 185 55 999 222Email: [email protected]

About Interxion

Interxion (NYSE: INXN) is a leading provider of carrier and cloud-neutral colocation data centre services in Europe, serving a wide range of customers through over 45 data centres in 11 European countries. Interxion’s uniformly designed, energy efficient data centres offer customers extensive security and uptime for their mission-critical applications. With over 600 connectivity providers, 21 European Internet exchanges, and most leading cloud and digital media platforms across its footprint, Interxion has created connectivity, cloud, content and finance hubs that foster growing customer communities of interest.

For more information, please visit www.interxion.com

Security ■ Security staff on site with controlled

access 24x7, 365

■ Multiple physical security layers including CCTV, proximity cards, man trap and biometrics

■ ISO 27001 information security management system

Energy efficiency ■ Guarantee of Origin certificates:

100% of power consumption produced from renewable resources

■ Operated betond the industry standards for energy-efficiency

■ Installation of Cabinets in cold aisle containment

■ Chillers with free cooling

Customer SupportISO 22301 Accredited for BusinessContinuity Management.

ISO 27001/IEC Accredited European Customer Service Centre (ECSC) providessupport in 11 countries according to thesame rigorous standards:

■ 24x7, 365 facility and service monitoring in real-time

■ Multi-lingual response (French, English, Spanish, German and Dutch

Controlled Environment ■ Very Early Smoke Detection

Apparatus (VESDA)

■ Optical detectors in the room every 9m2 and in the technical floor

■ Inert gas fire suppression system

■ SLAs on temperature and humidity in line with the 2011 ASHRAE recommendations

■ Minimum N+1 CRAC redundancy per customer room

■ Entire facility infrastructure monitored 24x7, 365 in real-time (Chillers, CRAC units, Fire Panels, Generators, UPS in Hexaload configuration)

I N D I A N

O C E A N

A T L A N T I C

O C E A N

BURKINAFASO

GERMANY

M A D A G A S C A R

TAJIKISTAN

BAHRAINL I B Y A

PORTUGAL

DJIBOUTI

KYRGYZSTANGREECE

KOS.

SIERRALEONE

CROATIA

QATAR

CAMEROON

TANZANIA

MYANMAR

ALB.

MONT.

HONGKONG

BENINN I G E R I A

I R A N

BULGARIA

SENEGAL

LIBERIA

CENTR ALAFRIC AN REP.

OMANM AURITANIA

MALAYSIA

AFGHANISTAN

NETH.

TOGO

HUNGARY

ROMANIA

SOUTHSUDAN

IVORYCOAST

BOS. &HERZ.

LUX.

MOLDOVA

UGANDA

GABON

K A Z A K H S T A N

R U S S I A

U.A.E.

M O Z A M B I Q U E

TURKEY

SRILANKA

IRAQ

E G Y P T

LEBANON

SERBIA

BOTSWANA

I N D I A

ZIMBABWE

POL AND

C H A D

RWANDA

LITHUANIA

S U D A N

GUINEABISSAU

KENYA

SLOVENIA

CZECH REP.

ITALY

MOROCCO

TURKMENISTAN

SYRIA

LAOS

KUWAIT

BHUTAN

SOM ALIA

FRANCE

SPAIN

WESTERNSAHARA

S O U T HA F R I C A

TUNISIA

AZERBAIJAN

VIETNAM

A L G E R I A

JORDANISRAEL

PALESTINIANTERR.

BURUNDI

COMOROS

MAURITIUS

REUNION

SLOVAKIA

ANDORRA

ERITREA

GEORGIA

LIECH.

BEL ARUS

BANGLADESH

IRELAND

M A L I

PAKIS TAN

BRUNEI

CONGO

YEMEN

LESOTHO

INDONESIA

GHANA

D E M .R E P . O FC O N G O

EQ. GUINEA

GUINEA

E T H I O P I A

Z A MBIA

U K R A I N E

MACAU

SWAZILAND

SWITZ.

N I G E R

CYPRUS

MAC.

C H I N A

UNITEDKINGDOM

CAMBODIA

AUSTRIA

UZBEKISTAN

S A U D IA R A B I A

ARMENIA

A N G O L A

THAILAND

NEPAL

MALAWI

N A M I B I A

GAMBIA

BELGIUM

SINGAPORE

SAO TOME AND PRINCIPE

M O N G O L I A

Dublin

Amsterdam

Brussels

Madrid

Vienna

London

Frankfurt

Paris

Zürich

Dusseldorf

SeaMeWe-4

EIG

AC

E

AC

E [2

018

]

SA

T-3/

WA

SC

WA

CS

SACS [2018]

WA

CS

GLO

-1

MAREA [2018]

Brexit-1

Brexit-1

Europe India Gateway

SeaM

eWe-

4

SeaM

eWe-

5

AAE-1

IMEWE

Atlas O�shore

Med Cable Network

AA

E-1

IMEWE

TE North/TGN-Eurasia/SEACOM/Alexandros

SeaMeWe-5

SAFE

Libreville-Port Gentil

Ceiba-1SEACOM/Tata TGN-Eurasia

AA

E-1

EASSy

SeaMeWe-4AAE-1SRG-1 [2018]

G2A [2018]

Hawk Tamares

Djibouti City

Fujairah

Jeddah

Bizerte

Doha

Kuala Kurau

Suez

Pentaskhinos

Marmaris

Melaka

Oran

Satun

Abu Talat

SihanoukvilleVung

Tau

Singapore

Yeroskipos

Algiers

Colombo

Mumbai

Tripoli

Haifa

TuasDumai

Medan

Palermo

Bari

Cania

Muscat

Marseille

Cox’s Bazar

Aden

Hong Kong

Annaba

Karachi

Salalah

BosasoBerbera

RawalpindiTorkham

Chaman

Kabul

Kashgar

Kandahar

Gwadar

Chennai

Songkhla

Asilah

Catania

Zafarana

Alexandria

Al Hudaydah

Yanbu

Toulon

Monaco

Kuakata

Bude

Barka

Tripoli

Ngwe Saung

GibraltarSesimbra

Mtunzini

Mombasa

Port Sudan

Mogadishu

Batam

Maputo

Toliara

Dar Es Salaam

Moroni

Baie Jacotet

Libreville

Kribi

Freetown

Accra

El Goro

Monrovia

Point Noire

Seixal

Cape Town

Santana

Swakopmund Saint Paul

Nouakchott

Lagos

Banjul

Limbe

Bata

Penang

Cochin

Melkbosstrand

Port Gentil

Conakry

Highbridge

Malabo

Cotonou

Lisbon

Bilbao

Tenerife

Douala

Lome

Dakar

Abidjan

Muanda

Penmarch

Walvis Bay

SanganoLuanda

Yzerfontein

Interxion Data Centre LocationsLanding Station

In-Service Submarine CablesConnected to Marseille

AAE-1Atlas O�shoreEIGHawk / TamaresIMEWEMed Cable NetworkSeaMeWe4SeaMeWe5TE-North / Tata TGN / Seacom/ Alexandros

Planned Submarine CablesConnected to Marseille

MAREA [2018]Brexit-1

PotentialCapacity

(Tbps)

400.32

18209.6

1.286.42430

Source: Interxion/TeleGeography, version n°2, 2017

Interxion Marseille CampusGateway to EMEA and APAC