manufactured housing catalog - dec-o-artebiz.dec-o-art.com/envaalogin/html/catalogs/mh catalog for...

15
Manufactured Housing Catalog Required & Informational Over a million labels in stock All labels meet or exceed code data requirements Many Labels are available bilingual, call for quotes On-line catalog at www.dec-o-art.com 3914 Lexington Park Drive • Elkhart, IN 46514-1194 • 800.225.6879 • 574.294.6451 Fax 800-295-6534 • Email: [email protected] • www.dec-o-art.com MH.06.11

Upload: others

Post on 27-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

Manufactured Housing CatalogR e q u i r e d & I n f o r m a t i o n a l

Over a million labels in stockAll labels meet or exceed code data requirementsMany Labels are available bilingual, call for quotesOn-line catalog at www.dec-o-art.com

3914 Lexington Park Drive • Elkhart, IN 46514-1194 • 800.225.6879 • 574.294.6451Fax 800-295-6534 • Email: [email protected] • www.dec-o-art.com

MH.06.11

Page 2: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

1

Member

Member

Member

Member

• All orders confirmed via fax.

• Over a million labels in stock

• Rush orders shipped the same day

• Larger quantities available - call for quote

• All items are packaged in 100’s

Terms:Open account terms with approved credit. Alternatives are credit card (Visa, MasterCard and American Express), C.O.D. with a $20.00 C.O.D. charge, or cash with order. Prices do not include shipping and are subject to change with-out notice.

Design Certificate 2

Health Notice 3

Appliances 4-5

Electrical 6-7

Gas 8

Set-Up 9

Miscellaneous 10

Non-Storage 11

Plumbing 12

Federal Certification 13

Index/Pricing (not in online version) 14-15

Table of Contents

Page 3: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

See pages 14-15 for pricing and volume discounts2

**All labels printed on White Vinyl except where noted in the description.

ED-71 (Replaces ED-70)• Size8.50X11.003partform• Printsonstandardlaserprinter• ED-901templaterequiredfor entering data.• EachED-71includesoneadhesive backedformandtwopaper copies.

ED-901• Exceltemplateforfillingout ED-71forms.• Includesoptionsfor: ✓Wind Zones ✓RoofLoads ✓Air Conditioning ✓Humid & Fringe ClimatesMicrosoft® Excel must be installed in your computer.

Design Certificate

BASIC WIND ZONE MAP

MIDDLE

MIDDLE MIDDLE

NORTH

NORTH

SOUTH

HI

ZONE IIIZONE III ZONE III

ZON

E III

ZONE IIIZONE II

ZONE II

ZON

E II

ZONE I

ZONE I

U/O VALUE ZONE MAP

MT

WA

ORID

WY

ND

SD

MN

IA

WI

IL INNV

UTCO

AZNM

OK

NEOH

WV VA

PA

NYMI

VT MENH

MA

RICT

NJ

DE

MD

AK

HI

TX LAMS AL

SC

GA

FL

AR

KS MO

NCTN

KYCA

U-VALUES

0.116

0.096

0.079

1

2

3

ZONES

ED-71 ©2006 Dec-O-Ar t, Inc. 03/06

Re-Order From DEC-O-ART, Inc., Elkhart, IN 46514 Phones: (800) 255-6879 or (574) 294-6451 Fax (574) 295-6534 Part Number: ED-71PEEL HERE PEEL HERE

Page 4: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

800-225-6879 • (fax) 800-295-6534 • [email protected] 3

**All labels printed on White Vinyl except where noted in the Description.

3

Health NoticeDD-92whitepaper(8.50X11.00)

DO6004(ParkModelRequired)4m white vinyl removable(21x8)

Page 5: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

See pages 14-15 for pricing and volume discounts4

**All labels printed on White Vinyl except where noted in the description.

Appliance

NOTICEWHEN WASHER OR DRYER IS

INSTALLED, THIS COMPARTMENTMUST BE VENTILATED PER THEAPPLIANCE MANUFACTURER'S

INSTRUCTIONS. AD-45

"THIS SPACE FOR CLOTHESWASHER AND/OR DRYER.APPLIANCES SHALL NOT

EXTEND MORE THAN27 INCHES FROM THE WALL."

AD-53

DD-85

This appliance has been installed with the flue/vent assembly partially disassembled. The flue/vent assembly MUST be completed in accordance with the DAPIA-approved appliance manufacturer’s installation instructions before occupancy by the owner.

WARNING

WARNINGDRYER MUST BE VENTED OUTSIDE HOME

1. Vent duct must extend thru the floor and bottom board of home, and then to the side of the home and be attached to a termination fitting.

2. If the home is skirted, the dryer vent must terminate outside of the skirting.

3. When an electrical receptacle for a dryer is installed at the factory, holes for the vent are cut in the flooring and bottom board and covered. Remove the covers and install the vent from the dryer, through the holes in the floor to the underside of the home, and then to the side of the home.

CD-91

AD-45(3¼X1¾)

AD-53(3¼X1¾)

DD-85removablewhitevinyl(5X3)

RD-003(4¾X1¾)

CD-91(5X3)

AVAILABLE CLEARANCEAREA

DEPTH INCHESWIDTH INCHES

AD-68

AD-68whitepaper(3¼X1¾)

AD-82(ParkModelRequired)(3¼X1¾)

Page 6: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

800-225-6879 • (fax) 800-295-6534 • [email protected] 5

**All labels printed on White Vinyl except where noted in the Description.

Appliance

WARNINGDryer exhaust duct must extend to the out- side of the home and be connected to a termi-nation fitting. Termination of the duct in the floor cavity or under the home could result in a serious fire hazard or structural damage due to excessive moisture.

CS-36

CS-67

WARNING!The furnace has been shipped with a temporary cover over the flue pipe. The temporary cover must be removed and the rain cap installed on the roof jack prior to operation of the furnace.

CS-67fluorescentorangepaper(6X3½)

CS-36(6X27/8)

CS-91(ParkModelRequired)(6¼X2¾)

FA0050(ParkModelRequired)(3¼X3)

WARNING

GD0005

These appliances and or fireplaces havebeen installed with flue assembly partiallydisassembled. The flue assembly MUST becompleted in accordance with the DAPIAapproved appliance manufacturer's installa-tion instructions prior to the occupancy bythe owner.

GD0005(4¾X1¾)

Page 7: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

See pages 14-15 for pricing and volume discounts6

**All labels printed on White Vinyl except where noted in the description.

Electrical 1

THIS CONNECTION FOR120/240 VOLT,

3-POLE, 4-WIRE,60 HERTZ,

200 AMPERE SUPPLY.AD-95

THIS CONNECTION FOR120/240 VOLT,

3-POLE, 4-WIRE,60 HERTZ,

200 AMPERE SUPPLY. AD-95M

THIS CONNECTION FOR120/240 VOLT,

3-POLE, 4-WIRE,60 HERTZ,AMPERE SUPPLY.

AS-32

THIS CONNECTION FOR120/240 VOLT,

3-POLE, 4-WIRE,60 HERTZ,AMPERE SUPPLY.

AS-32M FM-09

THIS CONNECTION FOR120/240 VOLT,

3-POLE, 4-WIRE,60 HERTZ,AMPERE SUPPLY.100

THIS CONNECTION FOR120/240 VOLT,

3-POLE, 3-WIRE,60 HERTZ,AMPERE SERVICE

AD-29M

THIS CONNECTION IS FOR AIR CON-DITIONING EQUIPMENT RATED AT

NOT MORE THAN AMPERES AT VOLTS, 60 HERTZ. A DIS-

CONNECT SHALL BE LOCATEDWITHIN SIGHT OF THE APPLIANCE.

AD-31AD-31M

THIS CONNECTION IS FOR AIR CON-DITIONING EQUIPMENT RATEDAT NOT MORE THAN .AMPERES AT VOLTS,

60 HERTZ. A DISCONNECT SHALLBE LOCATED WITHIN SIGHT OF THE

APPLIANCE.

AD-95chromepolyester(3¼X1¾)

AS-32Mmetal(3X1¾)

AS-96(ParkModelRequired)(3¼X1¾)

FM-09metal(3¼X1¾)

AD-29Mmetal(3¼X1¾)

AS-32(3¼X1¾)

AD-95Mmetal(3X1¾)

AD-31(3¼X1¾)

AD-31Mmetal(3¼X1¾)

FA0047 metal(3X1¾)

FA0049metal(3X1¾)

AIR-CONDITIONING CIRCUIT.THIS CONNECTION IS FOR

AIR CONDITIONERSRATED 110-125-VOLT AC, 60 HZ,

AMPERES MAXIMUM.DO NOT EXCEED CIRCUIT RATING.

THIS CONNECTION IS FOR HEATING

AND/OR AIR-CONDITIONING EQUIPMENT.

THE BRANCH CIRCUIT IS RATED AT NOT MORE

THAN AMPERES, AT VOLTS,

60 HZ, CONDUCTOR AMPACITY.

A DISCONNECTING MEANS SHALL BE

LOCATED WITHIN SIGHT OF THE EQUIPMENT.

Page 8: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

800-225-6879 • (fax) 800-295-6534 • [email protected] 7

**All labels printed on White Vinyl except where noted in the Description.

AS-32A(ParkModelRequired)(3¼X1¾)

FM-046(3¼X1¾)

Electrical 2

FM-046

REMOVE THIS PANELFOR ACCESS TO

ELECTRICAL

ELECTRICALCROSS-OVER

LOCATIONLH-007

AD-19

WARNING! This circuit shall not be turned on until water heater tank is completely filled. Dry operation may overheat or damage the water heater elements.

LOCK-OUT DEVICE LOCATION

This Panelboard shall be connected by a Feeder Assembly having Overcurrent Protection rates at not more than 200 Amperes. BD-94

This Panelboard shall be connectedby a Feeder Assembly having

Overcurrent Protection rates at notmore than Amperes.

BS-18

WARNING!THIS CIRCUIT SHALL NOT BE TURNED ON UNTILWATER HEATER TANK IS COMPLETELY FILLED.DRY OPERATION MAY OVERHEAT OR DAMAGE

THE HEATER ELEMENTS AD-44

LH-007(3X1½)

AD-19(3¼X1¼)

AS-14B(ParkModelRequired)(3¼X1¾)

BD-94(3¼X7/8)

BS-1860# white paper, crack & peel(3¼X7/8)

AD-44(3¼X7/8)

AD-62(3¼X7/8)

Page 9: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

See pages 14-15 for pricing and volume discounts8

**All labels printed on White Vinyl except where noted in the description.

Gas

WARNING !!This gas outlet is only

for the supply connectionof a gas dryer.

AD-60

Combination LP-Gas and Natural Gas SystemThis gas piping system is designed for use of either

liquefied petroleum gas or natural gas.

NOTICE: BEFORE TURNING ON GAS BE CERTAIN APPLIANCES ARE DESIGNED FOR THE GAS CONNECTED AND ARE EQUIPPED WITH CORRECT ORIFICES. SECURELY CAP THIS INLET WHEN NOT CON-NECTED FOR USE.When connecting to lot outlet, use a listed gas supply connector for manufactured homes rated at:

100,000 BTUH or more:250,000 BTUH or more.

Before turning on gas, make certain all gas connections have been made tight, all appliance valves are turned off,

any unconnected outlets are capped.After turning on gas, test gas piping and connections to appliances for leakage with soapy water or bubble solution, and light all pilots.

DS-17

Combination LP-Gas and Natural Gas SystemThis gas piping system is designed for use of either

liquefied petroleum gas or natural gas.NOTICE: BEFORE TURNING ON GAS BE CERTAIN APPLIANCES ARE DESIGNED FOR THE GAS CONNECTED AND ARE EQUIPPED WITH CORRECT ORIFICES. SECURELY CAP THIS INLET WHEN NOT CON-NECTED FOR USE.When connecting to lot outlet, use a listed gas supply connector for manufactured homes rated at:

100,000 BTUH or more:250,000 BTUH or more.

Before turning on gas, make certain all gas connections have been made tight, all appliance valves are turned off,

any unconnected outlets are capped.After turning on gas, test gas piping and connections to appliances for leakage with soapy water or bubble solution, and light all pilots.

DS-17M

AD-60(3¼X1¾)

DS-17A(ParkModelRequired)(59/16X3¼)

FA0046(ParkModelRequired)(4X3)

DS-17(41/8X3¼)

DS-17Mwhitemetal(41/8X3¼)

DOA340(ParkModelRequired)(59/16X3¾)

Page 10: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

800-225-6879 • (fax) 800-295-6534 • [email protected] 9

**All labels printed on White Vinyl except where noted in the Description.

Set-Up

SUPPORTPIER

REQUIREDAT THIS

LOCATION

DD-41

ATTENTION!

ATTENTION!

THE STRUCTURAL DESIGN OFTHIS UNIT REQUIRES PIERING ATSPECIFIC LOCATIONS UNDERTHE HOME.

SEE THE TECHNICAL INSTALLA-TION MANUAL FOR DETAILEDPIERING INFORMATION.

THE STRUCTURAL DESIGN OFTHIS UNIT REQUIRES PIERING ATSPECIFIC LOCATIONS UNDERTHE HOME.

SEE THE TECHNICAL INSTALLA-TION MANUAL FOR DETAILEDPIERING INFORMATION.

SUPPORTPOST PIERSREQUIRED

AT THISLOCATION

SKY002

FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN SERIOUS INJURY OR DEATHSKY001

WARNINGONLY EXPERIENCED PERSONS KNOWLEDGEABLE OF MANUFACTURED HOMESET-UP PROCEDURES SHOULD SET UP THIS HOME.

WHEN SETTING UP THIS HOME, THE FOLLOWING PRECAUTIONS REGARDINGJACKING MUST BE FOLLOWED:1. Before doing any jacking, place support piers for the home in the locations under the home as specified in the home installation instructions. The experienced person setting up this home should be familiar with the National Fire Protection Association Standard for Manufactured Home Installations, NFPA No. 501A and the Manufactured Home Installation Instructions.2. Use a minimum of two jacks, each with a rating of at least five tons.3. Jack only on the main chassis I-beam. Locate the jack directly under the vertical web of the I-beam. Do not jack on the seam (joint between flanges) of a twin I-beam.4. Use a large 3/8 inch thick steel plate, C-channel or other equivalent plate between the main chassis I-beam and the jack head to distribute the load.5. The jack base, and any blocking must be located on firm ground.6. Do not operate the jacks while under the home.7. Use jacks only for raising the home. Do not rely on the jacks to support the home.8. Raise the home in small increments and provide additional blocking between the home and the piers as the home is raised.9. Do not go under the home while it is supported on the jacks.

PIER BLOCKINGREQUIRED

ON EACH SIDEFM-080

DD-41(27/8X25/8)

SKY0012mmwhiteexp.vinyl(7½X61/8)

SKY002yellowvinyl(10X4)FM-080yellowvinyl

(2X1)

MH4001(3X1¾)

Page 11: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

See pages 14-15 for pricing and volume discounts10

**All labels printed on White Vinyl except where noted in the description.

Miscellaneous

REMOVE THIS PANELFOR ACCESS TO

DD-93

THIS HOME IS INSULATED WITH FIBERGLASSINSULATION WITH THE FOLLOWING VALUES:

SPACE INSULATION"R" VALUE

ADVERTISEDTHICKNESS

FLOOR

WALL

CEILING

PULL-OUT

CD-106

MOISTURE NOTICEMany building materials may mildew if they become damp. Circumstances that encourage moisture are numerous and include environmental factors, site grading and inadequate ventilation.

Moisture may be reduced, in part, by the following:

• Proper site preparation • Completion of installation procedures • Routine maintenance • Regular use of exhaust fans and proper ventilation

These examples are intended to provide suggestions and notrepresentations as to the effectiveness of any particular action.

Specific information concerning moisture issues is contained inyour Homeowner’s Guide and Installation Manual, and you should consult the owner's manual for further information.

If you have any questions concerning the maintenance or installation of your home, please consult the retailer from whom the home was purchased or the manufacturer.

The mobi le home data plate is located

in the master bedroom closet .BS-30

DD-93removablewhitevinyl(3¼X1¾)

DD-84removablewhitevinyl(4¼X2½)

FM-421(5X4½)

CD-106removablewhitevinyl(37/8X5¾)

BS-30(3X¾)

Write-On Surface Removable Vinyl

Write-On Surface Removable Vinyl

Write-On

Surface Removable

Vinyl

W H O L E - H O U S EV E N T I L AT I O N

DO NOT USE TOOLS TO SEPARATE THE

" QUICK-DISCONNECT" DEVICE.

BD-20•black&whiteletters•supplied10persheet•2mclearvinyl(15/16X3/8)

AS-88(ParkModelRequired)(3¾X1½)

AD-50M19maluminum(3X1¾)

AD-27C 4m clear vinylAD-27W(ParkModelRequired)(3¼X1¾)

WIRES FORPHONE HERE

FM-10

FM-10(1½X1)

Page 12: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

800-225-6879 • (fax) 800-295-6534 • [email protected] 11

**All labels printed on White Vinyl except where noted in the Description.

Non-Storage

CAUTIONThis Compartment is

Not for StorageDo not store anything in this Compartmentas it may cause a fire hazard.

CS-35

CS-35fluorescentorangepaper(7¼X3¾)

DD-67(5X3)

AD-11(ParkModelRequired)(3¼X17/8)

This compartment is not to be used as a storage area. Storage of combustible materials or containers on or near any appliance in this compartment may create a fire hazard. Do not store such materials or containers in this compartment.

WARNING

DD-67

Page 13: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

See pages 14-15 for pricing and volume discounts12

**All labels printed on White Vinyl except where noted in the description.

Plumbing

FRESH WATERCONNECTION

REMOVE THIS PANELFOR ACCESS TO

DD-93

SEWER OUTLETCONNECTION DRAIN OUTLET

AD-18M

DRAIN OUTLET

CAUTION: THE WATER DISTRIBUTION SYSTEM IN THIS HOME WAS DESIGNED FOR A MAXIMUM WATER PRESSURE OF 80 POUNDS PER SQUARE INCH (PSI) AT THE INLET. IF THE WATER PRESSURE EXCEEDS 80 PSI, YOU MUST INSTALL A PRESSURE REDUCING VALVE AT THE INLET.

AD-81

FRESH WATER CONNECTION

CAUTION: THE WATER DISTRIBUTION SYSTEM IN THIS HOME WAS DESIGNED FOR A MAXIMUM WATER PRESSURE OF 80 POUNDS PER SQUARE INCH (PSI) AT THE INLET. IF THE WATER PRESSURE EXCEEDS 80 PSI, YOU MUST INSTALL A PRESSURE REDUCING VALVE AT THE INLET.

AD-81M

FRESH WATERCONNECTION

ACCESS FOR(P)TRAP INSPECTION

OR REPAIRJD-07

AD-16(3¼X1¼)

AD-16Mwhitemetal(3X1¾)

DD-93removablewhitevinyl(3¼X1¾)

AD-47 chrome polyester(3¼X1¼)

AD-18chromepolyester(3¼X1¼)

AD-18Mwhitemetal(3X1¾)

AD-81(3¼X1¾)

AD-04(ParkModelRequired)(3¼X2)

AD-81Mwhitemetal(3¼X1¾)

JD-07(3¼X1¾)

Write-On Surface Removable Vinyl

Page 14: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

800-225-6879 • (fax) 800-295-6534 • [email protected] 13

**All labels printed on White Vinyl except where noted in the Description.

Federal Certification

SERIAL #:

GROSS VEHICULAR WEIGHT (GVWR) OF HOME:

GROSS WEIGHT OF CARGO SHIPPED IN OR ON UNIT WITHOUT EXCEEDING GVWR:

MANUFACTURER

GD0006

GD0006 white metal(4X2)

Page 15: Manufactured Housing Catalog - Dec-O-Artebiz.dec-o-art.com/EnvAALogin/html/Catalogs/MH Catalog for web.pdfAll labels meet or exceed code data requirements Many Labels are available

Custom Product Safety Decals

Deco-Lens™(Polyurethane Capping)

Information Labels

Nameplates

Prespaced Decals

Paint Masks

Control Panel Graphic Overlays

Dec-O-Art Mission Statement

Our business is God’s Gift to us, Our work is our gift to GodOur primary purpose is to promote and improve the image of our customers through the graph-ic arts media. Dec-O-Art is dedicated to providing quality graphic services to our customers, meeting their standards, competitively priced and delivered in a timely manner. We will com-pete fairly while contributing to a standard of excellence within the industry, put service before cost cutting and will exhibit a sense of social responsibility toward our local community. We believe in a team concept among all our valued employees and we provide compensation that will reward our staff for contributing to that effort.

Quality PolicyDec-O-Art is dedicated to providing quality graphic products.

We ship on time, and right each time. Guaranteed.