Manual PCE-830 power anlayser
1. Definit
2. Over-v eq
3. Pl
1. Do no
2. Do no
3. Do no
4. Cons
5. Do no
1. Do n
4. Do
1. Don’t weari 2. Alway probe 3. Don’t
tion of Sym
voltage ca
quipment in f
WARNINGNot speciProv ided
lease read
ot operate in w
ot operate in p
ot touch expos
sider the use o
ot operate in
not operate wh
on’t use th
install the flexng protective c
ys inspect ande if any damag
use the flexib
mbols:
Caution
Double
Caution
ategory III
fixed installa
G: If the powfied by th by the c l
d the follow
wet or dusty en
presence of co
sed metal part
of rubber glove
excess of AC
hen the unit se
he flexible
xible current prclothing and g
d check any dage is found.
le current prob
n: Refer to Acc
e Insulation
n: Risk of Elec
(CAT III):
ations.
wer analyzee manuf acamp me te
wing instr
nvironments.
ombustible or e
ts, unused term
e in operation.
C 500V (Phase
eems to be ma
e current p
robe around baglove suitable f
amage of the c
be on circuit ra
companying D
ctric Shock
er is used incturer, theer may be
ructions b
explosive gas
minals.
e to Neutral),
al-functioning
probe befo
are conductorfor high-voltag
current probe
ated higher tha
Documents
n a manner protect io impa i red
before usa
or AC 600V (
ore you re
rs carrying a voe work.
assembly befo
an 600V in inst
i
n .
age
(Phase to Pha
ead the fol
oltage from 30
fore usage. Do
tallation categ
info@tursdaletec
ase)
llowing in
0V to 600V un
on’t use the fle
gory III.
chnicalservices.co
structions
nless you are
exible current
o.uk
2
s.
3
5. FEATURES
• Analysis for 3P4W, 3P3W, 1P2W, 1P3W
• True RMS value (V123 and I123)
• Active Power (W, KW, MW, GW)
• Apparent and Reactive Power (KVA, KVAR)
• Power Factor (PF), Phase Angle (Φ)
• Energy (WH, KWH, KVARH, PFH)
• Current measurement from 0.1mA to 1000A, capable of analyzing IT standby power consumption to the maximum demand of a factory
• Display of 35 Parameters in One Screen (3P4W)
• Programmable CT (1 to 600) and PT (1 to 3000) Ratios
• Display of Overlapped Voltage and Current Waveform
• Average Demand (AD in W, KW, MW)
• Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period
• Harmonic Analysis to the 99th Order
• Display of 50 Harmonics in one Screen with Waveform
• Display of Waveform with Peak Values (1024 Samples / Period)
• Analysis of Total Harmonic Distortion (THD-F)
• Graphic Phasor Diagram with 3 Phase System Parameters
• Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
• DIP, SWELL, and OUTAGE are included in transient events.
• 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR)
• 3 Phase Voltage or Current Unbalance Factor (d0%, d2%)
• Calculated Unbalanced Current through Neutral Line (In)
• 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system)
• Output of Waveform, Power Parameters and Harmonics at Command
• Large Dot Matrix LCD Display with Backlight
• Optical Isolated RS-232C to USB Interface
• Built-in timer and calendar for data logging
• Option: 300XP Portable Thermal Printer
5
1. Input Terminal for Neutral Line (Voltage)
2. Voltage Input Terminals for Each Phase (V1, V2, V3)
3. External DC Input (The AC adaptor must be 600V isolated)
4. Current Input Terminals for Each Phase (I1, I2, I3)
5. LCD Display
6. Buttons
7. RS-232C Window
8. Stand Holder
9. Stand
10. Battery Cover
11. Battery Compartment
P
P
Pth
P
P
P
P
u
P
ress this butto
ress this butto
Press this buttohe displayed d
Press this butto
Press this butto
Press this butto
ress this butto
Press this butup the increm
Press this butt
on to exit trans
on to perform t
on to hold the data. Press HO
on to start mea
on to select V1
on for the volta
on to enter SET
tton to incremeent.
ton to decrem
ient detection
transient detec
data displayedOLD button ag
asurement of
1, I1, V2, I2, V
age or current
TUP mode an
ent value by o
ent value by o
or to exit SET
ction.
d in LCD. Presgain to continu
harmonics in m
V3, or I3 for har
input range
nd then select
ne. Hold the b
one. Hold the b
TUP menu.
ss this button ue operation.
magnitude.
rmonics analy
the parameter
button for two s
button for two
i
and then REC
ysis
r to be adjuste
seconds or mo
seconds or m
info@tursdaletec
C button to rec
ed
ore to speed
more to speed
chnicalservices.co
cord
up the
o.uk
6
7. 6801 C
1. Jaw
2. Trigg
3. Rang
4. 6 pin
increment.
In the mo
In the mo
Press thisdisplayed
In the momode of h
Press this
Press this
Press thi
Press thi
In the m 3P3W, I2), or (V
Press th
Current Pr
Assembly
ger
ge Selector
n mini DIN con
ode of harmon
ode of harmon
s button to stad in LCD pointe
ode of power mharmonic anal
s button to turn
s button to star
s button to dis
s button to dis
mode of power1P2W or 1P3V3, I3).
his button to tu
robe (100A
nnector
ic analysis, pre
ic analysis, pre
rt data logginged by SEC ind
measurement,lysis, press thi
n the back ligh
rt measureme
splay waveform
splay waveform
r parameter m3W). In the mo
urn the power
A)
ess this button
ess this button
g. Press it agdicator.
, press this butis button to dis
ht on. Press i
ent of power pa
m of voltage a
m of voltage o
measurement, pode of displayin
on or off.
n to move the
n to move the
gain to stop da
tton to displaysplay phase an
it again to turn
arameters.
nd current.
nly
press this buttng waveform,
i
cursor left to th
cursor right to
ata logging. Th
y the phasor dingle instead o
n the back light
ton to select appress this but
info@tursdaletec
he previous or
o the previous o
e sampling int
iagram. In thof magnitude.
t off.
ppropriate sytton to select (V
chnicalservices.co
rder.
order.
terval is
he
ystem (3P4W,V1, I1), (V2,
o.uk
7
8. 6802 C
1. Jaw
2. Trigg
3. Rang
4. 6 pin
9. 3007 C
1. Coup
2. Flex
3. Mini-
4. Outp
NW
Current Pr
Assembly
ger
ge Selector
n mini DIN con
Current Pr
pling Assemb
ible Loop
-DIN connecto
put Range Sel
NOTE: Toselect CLselect 10
NOTE: To setuWhen the CLA
robe (1000
nnector
robe (3000
ly
or for Output
lect Switch
o setup 100 A cLAMP. When00.
p 1000A curreAMP is reverse
0A)
0A)
current proben the CLAMP
ent probe as see video, press
as selected pis reverse vid
elected probes the ▲ or ▼
robe, press theo, press the
, press the SE▼ button to sel
i
e SETUP bott▲ or ▼ but
ETUP button toect 1000
info@tursdaletec
tom to tton to
o select CLAM
chnicalservices.co
MP.
o.uk
8
10. OPERA
1.2.
3.
W
NW
Nc
NS
ATING INS
Connect th Make sure
with the arrflexible currtion, the cor
Keep the p the conduc
WARNING: A
NOTE: To setupWhen the CLA
NOTE: Select connected to th
NOTE: Select the corre
WARNING: All the currensame range.measuremen
NOTE: Please pay spower analyz
STRUCTIO
he flexible prob the current flo
row marked onrent probe is crrect phase wi
probe couplingctor.
Always wear
p 3000A curreAMP is reverse
the correct Che power ana
rect frequency
nt probes co Mixed modnt.
special attentyzer.
ONS
be around the cowing directionn the probe coconnected in thll be displayed more than 25
appropriate
nt probe as see video, press
CLAMP in thalyzer, power a
(Hz) in the SE
nnected to thdels and diffe
ion to the flex
conductor. n is in consistenupling. If the
he right orientad in the oscillos5mm away from
e gloves in o
elected probe,the ▲ or ▼
he SETUP manalyzer will a
ETUP menu.
he power anaerent ranges s
xible current
nt
a- scope. m
operation.
press the SET button to sele
menu. When utomatically d
alyzer must beselected will
probes (mod
i
TUP button toect 3000.
the current detect the rang
e of the samecause incorre
del 3007) conn
info@tursdaletec
o select CLAM
probe is ge selected.
e model and rect result of
nected to the
chnicalservices.co
MP.
e
o.uk
9
10
11. Set up before operation
a) Press SETUP button to enter setup screen. Press SETUP again to select the item for setting
(the selected item will be displayed in reverse video).
b) After selecting the item, press ▲ or ▼ buttons to set up its value.
c) After finishing setting up, press EXIT button to leave setup mode.
1. Select the data for download: H means harmonics;
H in reverse video means HOLD screen data (if the data is the one you want, you can press HOLD button to display the data, and press HOLD button again to exit);
P means power data which can be a reference for downloading, the data in order is 0~84.
2. Shows the total logged data in the analyzer: max. 85 logging data.
3. REC DATE: shows the starting logging time of the 1st downloaded file.
4. Hz: set up the frequency (50, 60 or AUTO) of the system.
5. PT: set up PT value.
6. CT: set up CT value.
7. SEC: set up the interval seconds of logged data.
8. CLAMP: set up the clamps selected (100A, 1000A or 3000A).
9. MD TIME: set up the time of Maximum Demand (1~60 minutes).
10. TRANS REF: set up the transient voltage (which will be automatically changed in accordance with PT).
11. SDVP: set up upper and lower limits % of transient voltage detection.
12. YEAR: Set up “year” of calendar clock.
13. MONTH: Set up “month” of calendar clock.
14. DATE: Set up “date” of calendar clock.
15. HOUR: Set up “hour” of calendar clock.
16. MINUTE: Set up “minute” of calendar clock.
17. SECOND: Second can be displayed only (it can not be adjusted).
12. Power
a)
b)
c)
d)
e)
f)
r Quality o
Turn the powewill be display
Connect the fo
Connect the t
Connect the t
Clamp on to tprobe to the b
All parameters
of a 3 Phas
er on. Press thyed at the left b
four test leads
test leads to L1
three current p
the L1, L2, andback of it.
rs of the system
For the mean
se 4 Wire (
he POWER anbottom corner
to the voltage
1, L2, and L3 o
probes to the p
d L3 of the 3P4
m will be show
ing of each pa
(3P4W) Sy
3 4W
nd the 1Φ3Φ in the LCD.
e terminals V1,
of the 3P4W s
power analyze
4W system.
wn in LCD.
arameter, refer
ystem
buttons to sele
, V2, V3 and th
system.
er input termina
Make sure the
r to XIV. NOM
i
ect the 3P4W
he VN (Neutra
al I1, I2, and I3
e current flow f
MENCLATURE
info@tursdaletec
system. The t
al) of the syste
3.
from the front
E.
chnicalservices.co
type of system
em.
of the current
o.uk
11
m
13. Power
a)
b)
c)
d)
e)
r Quality o
Turn the powewill be display
Connect the fo
Connect the t
Clamp on to t
All parameters
Fo
of a 3 Pha
er on. Press yed at the botto
four test leads
three current p
the L1, L2, and
rs of the system
or the meanin
se 3 Wire
the POWER aom right of the
to the voltage
probes to the p
d L3. Make s
m will be show
g of each para
(3P3W) S
3 3W
and the 1Φ3Φe LCD.
e terminals L1,
power analyze
ure the curren
wn in LCD
ameter, refer to
Syste
W
Φ buttons to se
L2, and L3 of
er input termina
nt flow from the
o XIV. NOME
i
elect the 3P3W
f the system.
al I1, I2, and I3
e front of the c
ENCLATURE.
info@tursdaletec
W system. Th
3.
current probe to
chnicalservices.co
he type of syste
o the back of i
o.uk
12
em
t.
13
In this direction will find a vision of the measurement technique: http://www.industrial-needs.com/measuring-instruments.htm NOTE: "This instrument doesn’t have ATEX protection, so it should not be used in potentially explosive atmospheres (powder, flammable gases)."