Page 1: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 1

Manual

EPI 54391 EPI MM 1

54392 EPI MM 3

Page 2: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 2

Content

1. Introduction……………………………………………………………………………… 3

2. Hardware...……………………………………………………………………………… 4

2.1. Description...………………………………………………………………… 4

2.2. Menu………………...……………………………………………………….. 5

3. Installation...…………………………………………………………………………….. 6

3.1. Single installation…………………………………………………………… 6

3.2. Daisy chain installation…………………………………………………….. 6

3.3. Hardware setting, address………………………………………………… 7

3.4. Current/Voltage max threshold setting…………………………………… 7

3.5. Reset to factory setting…………………………………………………….. 7

4. Software…………………………………………………………………………………. 8

4.1. Log in………………………………………………………………………… 8

4.2. Web interface……………………………………………………………….. 8

4.3. SNMP OID list………………………………………………………………. 13

5. Technical specification…………………………………………………………………. 15

6. Warranty…………………………………………………………………………………. 15

Page 3: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 3

1. Introduction

The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules EPI MM, available in 1 phase and 3 phase version. The power distribution units will provide power regardless if a monitoring module is present

or not. With a EPI MM mounted in the power distribution unit is it possible to monitor:

-Input voltage (V)

-Total load current (A)

-Total power (kW)

-Energy consumption (kWh)

Included in the EPI MM is local monitoring or remote monitoring through IP.

Page 4: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 4

2. Hardware

2.1 DESCRIPTION

1. EPI PDU 2. EPI MM, IP monitoring module 3. LCD display 4. RUN indicator, flashes 1 second interval 5. KWH indicator, flash frequency depending on load current 6. ALM indicator, on when alarm occurs 7. Menu button, cycles through display screens, factory reset – see 3.5 8. UP button, used to set address or max threshold current/voltage 9. DOWN button, used to set address or max threshold current/voltage 10. RESET button, to reset the EPI MM 11. NET port, ethernet WAN/LAN communication port 12. SER port, daisy chain port (RS485) 13. LINK port, daisy chain port (RS485)

Page 5: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 5

2.2 MENU

Press >MENU< to cycle through display screens EPI MM 1, 1 phase model

Screen 1 Screen 2 Screen 3 Screen 1: Current(0.0A), voltage(220VAC), power(0.0kW), energy consumption(0.0kWh) Screen 2: Master/Slave address (0 to 4) Screen 3: Max threshold current(32.0A), max threshold voltage(276VAC) EPI MM 3, 3 phase model

Screen 1 Screen 2 Screen 3 Screen 4 Screen 5 Screen 6 Screen 7 Screen 1: L1 Current(0.0A), voltage(220VAC), power(0.0kW), energy consumpt.(0.0kWh) Screen 2: L2 Current(0.0A), voltage(220VAC), power(0.0kW), energy consumpt.(0.0kWh) Screen 3: L3 Current(0.0A), voltage(220VAC), power(0.0kW), energy consumpt.(0.0kWh) Screen 4: Master/Slave address (0 to 4) Screen 5: L1 Max threshold current(32.0A), max threshold voltage(276VAC) Screen 6: L2 Max threshold current(32.0A), max threshold voltage(276VAC) Screen 7: L3 Max threshold current(32.0A), max threshold voltage(276VAC)

Page 6: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 6

3. Installation

3.1 SINGLE INSTALLATION

Connect each EPI MM to WAN/LAN through RJ45 cable in the NET port.

3.2 DAISY CHAIN INSTALLATION

Connect one EPI MM to WAN/LAN through RJ45 cable in the NET port.

Connect the first slave unit from the Masters SER port to the Slave LINK port.

Repeat this for additional slave units. Maximum 4 slave units to 1 master.

Set each master/slave to individual addresses. See section 3.3.

Page 7: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 7

3.3 HARDWARE SETTING, ADDRESS

Press MENU button until Master/Slave address screen is displayed.

Press DOWN button to select Master/Slave address, range from 0 to 4.

Press UP button to set the value.

Press MENU button to save the setting. Hold until it beeps.

3.4 CURRENT/VOLTAGE MAX THRESHOLD SETTING

Press MENU button until max threshold screen is displayed.

Press DOWN button to select value to be set.

Press UP button to set the value. (Max 32A and 276VAC)

Press MENU button to save the setting. Hold until it beeps.

3.5 RESET TO FACTORY SETTING

Press and hold MENU button and power on the PDU at the same time to reset to factory

settings.

Page 8: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 8

4. Software

4.1 LOG IN

Log in to the EPI MM Master using a standard web browser.

Default IP address: 192.168.1.163

Default User Name: enoc

Default Password: enoc

4.2 WEB INTERFACE

DEVICE STATE

Displays the current Current, Voltage, Power and Energy for each phase (L1/L2/L3).

Page 9: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 9

THRESHOLD SETTINGS

Set the max/min threshold of current (0-32A) and voltage (170-276V)

DEVICE SETTINGS

Set the Device Name, Web server port, Working mode. Default settings are:

Device Name: IP-PDU

Web server port: 80

Working mode: Master

Changes will come in to effect after restart.

To reset the energy meter for each phase, press apply.

Page 10: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 10

USER SETTINGS

Set the User Name and Password. (Max length is 16 characters)

NETWORK

Set the desired network settings. Default setting are:

System IP: 192.168.1.163

Subnet Mask: 255.255.255.0

Default Gateway: 192.168.1.1

DNS: 202.96.128.86

Changes will come in to effect after restart.

Page 11: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 11

SNMP

Set the desired SNMP settings. Default setting are:

Get community: public

Set community: private

Trap1 ip: 0.0.0.0

Trap 2 ip: 0.0.0.0

Changes will come in to effect after restart.

E-MAIL ALARM SETTINGS

Set the desired SMTP settings.

Press >TEST< to send a test email to verify settings.

Page 12: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 12

RESTART

Page 13: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 13

4.3 SNMP OID LIST

OID Declaration

Device Name 1.3.6.1.4.1.30966.10.3.1.1 Master device name

mVoltage A 1.3.6.1.4.1.30966.10.3.2.1 Voltage of L1 for master device

mVoltage B 1.3.6.1.4.1.30966.10.3.2.2 Voltage of L2 for master device

mVoltage C 1.3.6.1.4.1.30966.10.3.2.3 Voltage of L3 for master device

mCurrent A 1.3.6.1.4.1.30966.10.3.2.4 Current of L1 for master device

mCurrent B 1.3.6.1.4.1.30966.10.3.2.5 Current of L2 for master device

mCurrent C 1.3.6.1.4.1.30966.10.3.2.6 Current of L3 for master device

mEnergy A 1.3.6.1.4.1.30966.10.3.2.7 Power energy of L1 for master device

mEnergy B 1.3.6.1.4.1.30966.10.3.2.8 Power energy of L2 for master device

mEnergy C 1.3.6.1.4.1.30966.10.3.2.9 Power energy of L3 for master device

sOneVoltage A 1.3.6.1.4.1.30966.10.3.2.10 Voltage of L1 for slave 1

sOneVoltage B 1.3.6.1.4.1.30966.10.3.2.11 Voltage of L2 for slave 1

sOneVoltage C 1.3.6.1.4.1.30966.10.3.2.12 Voltage of L3 for slave 1

sOneCurrent A 1.3.6.1.4.1.30966.10.3.2.13 Current of L1 for slave 1

sOneCurrent B 1.3.6.1.4.1.30966.10.3.2.14 Current of L2 for slave 1

sOneCurrent C 1.3.6.1.4.1.30966.10.3.2.15 Current of L3 for slave 1

sOneEnergy A 1.3.6.1.4.1.30966.10.3.2.16 Power energy of L1 for slave 1

sOneEnergy B 1.3.6.1.4.1.30966.10.3.2.17 Power energy of L2 for slave 1

sOneEnergy C 1.3.6.1.4.1.30966.10.3.2.18 Power energy of L3 for slave 1

sTwoVoltage A 1.3.6.1.4.1.30966.10.3.2.19 Voltage of L1 for slave 2

sTwoVoltage B 1.3.6.1.4.1.30966.10.3.2.20 Voltage of L2 for slave 2

sTwoVoltage C 1.3.6.1.4.1.30966.10.3.2.21 Voltage of L3 for slave 2

sTwoCurrent A 1.3.6.1.4.1.30966.10.3.2.22 Current of L1 for slave 2

sTwoCurrent B 1.3.6.1.4.1.30966.10.3.2.23 Current of L2 for slave 2

sTwoCurrent C 1.3.6.1.4.1.30966.10.3.2.24 Current of L3 for slave 2

sTwoEnergy A 1.3.6.1.4.1.30966.10.3.2.25 Power energy of L1 for slave 2

sTwoEnergy B 1.3.6.1.4.1.30966.10.3.2.26 Power energy of L2 for slave 2

sTwoEnergy C 1.3.6.1.4.1.30966.10.3.2.27 Power energy of L3 for slave 2

Page 14: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 14

OID Declaration

sThreeVoltage A 1.3.6.1.4.1.30966.10.3.2.28 Voltage of L1 for slave 3

sThreeVoltage B 1.3.6.1.4.1.30966.10.3.2.29 Voltage of L2 for slave 3

sThreeVoltage C 1.3.6.1.4.1.30966.10.3.2.30 Voltage of L3 for slave 3

sThreeCurrent A 1.3.6.1.4.1.30966.10.3.2.31 Current of L1 for slave 3

sThreeCurrent B 1.3.6.1.4.1.30966.10.3.2.32 Current of L2 for slave 3

sThreeCurrent C 1.3.6.1.4.1.30966.10.3.2.33 Current of L3 for slave 3

sThreeEnergy A 1.3.6.1.4.1.30966.10.3.2.34 Power energy of L1 for slave 3

sThreeEnergy B 1.3.6.1.4.1.30966.10.3.2.35 Power energy of L2 for slave 3

sThreeEnergy C 1.3.6.1.4.1.30966.10.3.2.36 Power energy of L3 for slave 3

sFourVoltage A 1.3.6.1.4.1.30966.10.3.2.37 Voltage of L1 for slave 4

sFourVoltage B 1.3.6.1.4.1.30966.10.3.2.38 Voltage of L2 for slave 4

sFourVoltage C 1.3.6.1.4.1.30966.10.3.2.39 Voltage of L3 for slave 4

sFourCurrent A 1.3.6.1.4.1.30966.10.3.2.40 Current of L1 for slave 4

sFourCurrent B 1.3.6.1.4.1.30966.10.3.2.41 Current of L2 for slave 4

sFourCurrent C 1.3.6.1.4.1.30966.10.3.2.42 Current of L3 for slave 4

sFourEnergy A 1.3.6.1.4.1.30966.10.3.2.43 Power energy of L1 for slave 4

sFourEnergy B 1.3.6.1.4.1.30966.10.3.2.44 Power energy of L2 for slave 4

sFourEnergy C 1.3.6.1.4.1.30966.10.3.2.45 Power energy of L3 for slave 4

Page 15: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 15

5. Technical specification

Rated input voltage: 110/220V 50/60Hz, 380V 50/60Hz

Max input current: 16A, 32A, 3x16A, 3x32A

Accuracy total voltage: ±1% + 2byte, resolution 200mV, response time 400ms

Accuracy total current: ±1% + 1byte, resolution 100mV, response time 400ms

Accuracy total power: Constant 1600imp/kWh, resolution 0.1kWh

Alarm: Email alarm, SNMP (v1) trap

Operating Temperature: 0℃ - 55℃

Operating Relative Humidity: 10% - 90%

Storage Temperature: -20℃ - 70℃

6. Warranty

Warranty valid within 2 years from the date of purchase.

Warranty is not valid if:

Damage caused by incorrect repair.

Damage caused by use out of allowed operating/storage environment.

Damage caused by accident or negligence.

Damage caused during transportation.

Page 16: Manual EPI · 2015. 8. 12. · EPI Manual V1.0 3 1. Introduction The EPI systems consists of power distribution units EPI, available in different configurations, and monitoring modules

EPI Manual

V1.0 16