HEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere. Hot water immediately available tanks to by recirculatio. Saving water, heat and energy. (page 2) Modular, easy to install and change also during installation (page 3) Total isolation, reduced heat loss. (page 4) Wide range of solutions obtainable according to the needs of user.(p.5-6-7-8) Electronic management of the single areas of use. (page 9) Minimal pressure drop. (p. 9-10) Economic and complete in every detail. Accounting for consumptions: domestic hot and cold, calories heating, refrigeration for cooling. Connection via twisted pair, M-bus or radio frequency with the manager and with the user. Display of heat meter and thermostat for recirculation can be positioned outside the box. Quick and easy to install, the installer only has to connect the pipes and the external electrical connections. The use of standard devices, in stock with us or readily available on the market, allows the replacement quickly and inexpensively A new revolutionary management and fluid distribution technique in buildings. INTEGRATED, MODULAR SECTIONAL AND VARIABLE IN WORK (Patented) A COMPLETE SOLUTION CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

Upload: hakhanh

Post on 05-Feb-2018

218 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

HEAT INTERFACE UNITS

MANAGEMENT OF HEATING AND AIR

CONDITIONING IN BUILDINGS

Compact. mm. 430x460x125 depth, installable anywhere.

Hot water immediately available tanks to by recirculatio.

Saving water, heat and energy. (page 2)

Modular, easy to install and change also during installation (page 3)

Total isolation, reduced heat loss. (page 4)

Wide range of solutions obtainable according to the needs of user.(p.5-6-7-8)

Electronic management of the single areas of use. (page 9)

Minimal pressure drop. (p. 9-10)

Economic and complete in every detail.

Accounting for consumptions: domestic hot and cold, calories heating,

refrigeration for cooling.

Connection via twisted pair, M-bus or radio frequency with the manager and with the

user.

Display of heat meter and thermostat for recirculation can be positioned outside the box.

Quick and easy to install, the installer only has to connect the pipes and the external electrical connections.

The use of standard devices, in stock with us or readily available on the market, allows the replacement quickly and inexpensively

A new revolutionary management and fluid distribution technique in buildings.

INTEGRATED, MODULAR SECTIONAL AND VARIABLE IN WORK (Patented)

A COMPLETE SOLUTION

CIRCUITI IDRAULICI E VALVOLE

DI RICCARDO FERRERO

Page 2: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 2 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

Compact

Hot water immediately available thanks to recirculation: saving water, heat and Energy. (Pat. Pend.)

The reduced size of the unit, that in addition to incorporate all the functions, allow installation near use. The integration of these features with the recycling of the hot sanitary water allows to have an immediate delivery of hot sanitary water with significant savings in energy, water and calories.

Operation An adjustable thermostat connected to a probe placed at the point of dispensing hot water allows to maintain a constant predetermined minimum value of its temperature.

The thermostat has a differential temperature of about 5 ° C., as this value is reached, the thermo-stat operates as follow.

:Series 10 unit, with instant production of hot sanitary water: The thermostat activates the heating pump that circulates the water until it reached the predetermined temperature at the entrance of the heat exchanger.

Series 20 unit, with the management of sanitary hot water storage: The thermostat controls the opening of the thermoelectric valve connected to the accumulation tank via a pipe. The valve in the open position, activates the hot sanitary water pump that circulates the water until restoration of temperature.

When the hot sanitary water has reached the set temperature, the thermostat stops the pump and closes the valve of recirculation.

A check valve allows the flow of hot water recirculation only towards the boiler.

In order to avoid contamination by legionella is sufficient to maintain the boiler temperature at 55 °C.

SAVINGS

1. The energy saving is ensured by the activation of the pump for a short time. 2 . The saving of water is made by the recycled water . 3. The saving of calories is given by the hot water that returns to the accumulation. 4. If the hot sanitary water in the accumulation is eg. at 55 °, but the usage is at 40 ° can be set this value, a low temperature allows a lower dispersion. For units in the version with thermostatic mixer, when the hot water from the pipe passes in the mixing valve will not be mixed, it will be mixed when it arrive from the accumulation.

Page 3: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 3 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

1 2 3

Modular, easy to install.

The units are composed of three different modules , and variously performed according to their functions and needs of the user, as follows:

1. Management or hot sanitary water and cold water. With termostatic mixer and re cycling of hot water.

2. Management of input primary hot water: Interception, flow regulation, filtration, one-way control of the flow. Flow controller by a motorized ball valve, watertight motor IP65. 3. Interception on boiler's primary flow return: accounting and management of the calories consumed. Flow accumulation with lung before the calorie counter.

Installation note. Connection to pipes can be made by releasing the module from the hardware, unscrewing the screw and then tilt the unit to the tube, screw them. Easier still is. 1. Unscrew the valve and fittings from the module.

2. Unhook the hardware module and move it.

3. Insert the valves in the pipes, tighten the fitting.

4. Screw the fitting of valves and fittings to the module.

5. Hang up the hardware module.

A further advantage of the separate modules: the possibility to position the unit directly on the pipes, compensating for any errors in cutting of them.

Page 4: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 4 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

Total insulation, minimal loss heat.

Even the isolation is complete and unique.

Instructions.

Leave pipe insulation leaning against the insulating box.

When installation is complete, push back the insulation tube and paste it to insulating box with a touch of suitable adhesive. The insulation of the pipes is all one with the box insulation.

The photo shows the unit SAT16, with recirculation inserted.

See how unit shows without and with the lid on.

Minimum heat loss in the environment mostly during the Summertime with the management of the hot water on.

Page 5: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 5 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

Unit SAT22 Similar to SAT 20, but without thermostatic mixing valve.

Unit SAT22_2

Similar to SAT 22, with reduced electonic control box (see page. 9)

Extreme flexibility of the system, unit adaptable to all the needs of end users.

BASIC UNIT: SERIES 20-22: high and low temperature management and centralized hot sanitary water. Accounting for sanitary cold and hot water, with two separate meters and data storage. Heating management: high and low temperature. Vertical or horizontal connections to heating. Available: in boxes of galvanized steel with extension and lower legs. Standard wall boxes with feet. Or without box, only with frame. The various modules fixed into the wall with threaded screw in the wall. We can provide the fitting for the holes.

Unit SAT20

With management of domestic hot water storage.

Heating and cooling management up to seven environments (seven programmable thermostats). (Description on p. 9)

Thermostatic mixer on hot sanitary water system.

Data transmission via twisted pair (M-bus) or HF both to the manager or to the end user.

Heat meter display is removable and is possible to fix it outside for a more convenient and easy detection.

Unit SAT20_2

Similar to the SAT20, but with reduced electronic central control.

It manages up to two zones, each one equipped with a motorized ball valve. E.G. an area manages the high temperature for radiators and fan coil and the other the low temperature.

The base zone can handle an unknown number of circuits, both at high and at low temperature controlled by thermoelectric valves driven directly by thermostats.

Or, by using only one zone, a single ball valve that manages both the low and the high temperature. The fluids are then divided into the distribution box. (see page. 9)

NOTE: The drawings show the satellites with fittings for pipes inserted, serve to illustrate the finished product. Fittings are listed separately and are contained in boxes attached to the satellite. They are contained into packs attached to the heat interface unit.

The customer in the order must specify characteristics of the tube and his diameters: internal and external. (see page 13)

SAT20

SAT20_2

SAT22

SAT22_2

Page 6: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 6 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

Unit SAT24

It has the same functions as SAT20, but with recirculation. (see page 2)

Management of heating and cooling up to seven environments (seven programmable thermostats).

Thermostatic mixer on hot sanitary water.

Data transmission via twisted pair (M-bus) or HF both to the manager or to the user.

Heat meter display and thermostat are removable and is possible to fix it outside for a more convenient and easy detection.

Unit for hot sanitary water management with storage and with recirculation. (See page 2)

Unit SAT24_2 Similar at SAT24, but with reduced electronic control box.

Unit SAT26 Similar to SAT24, but without termostatic mixing valve.

Unit SAT26_2 Similar to SAT26, but with reduced electronic control box. (See page 9)

Unit SAT34

Similar to SAT24, but with production of primary water at low temperature and circulator. (See page 2) For radiant panels that are installed separated. It serves to limit the distribution on place only with the manifolds.

SAT34_2 Similar to SAT34, but with reduced electronic control box

SAT33 Similar to SAT34, but without circulator of the sanitary hot wather

SAT33_2 Similar to SAT33, but with reduced electronic control box

SAT24

SAT24_2

SAT26

SAT26_2

SAT34

Page 7: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 7 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

INTERFACE UNIT SAT10 SERIE, COMMON FEATURES. Instantaneous production of hot sanitary water.

Accounting with a single heat meter both for heating and for the sanitary hot water.

Separate meter for the sanitary cold water. Heating management: high and low temperature. Vertical or horizontal connection to the heating.

Electronic storage of water consumption and calories.

Data transmission via twisted pair (M-bus) or HF both to the manager and to the end user. Heat meter display and thermostat are removable outside for a more convenient consumption detection

SAT12_2 Similar to SAT12, but with reduced electronical control. (see page 9)

SAT16 Similar to SAT12, but with ricircle of sanitary hot water.

SAT16_2 Similar to SAT16, but with reduced electronical control. (see page 9)

SAT12 Management of heating and cooling up to seven environments.

Box with the manifolds for the distribution of the high temperature heating: with radiators, fan coils, etc..

Is the basic model with the 4 manifolds of the head, shutoff valves, air vent and drain.

Customer must insert the number of collectors is needed of the

series 700. (see p.13 and 14)

Each manifold occupies the space of 50 mm.

Adding the measures incorporated in the illustration, plus spaces on the sides, and the number of collectors, you obtain the lenght of the box.

It is possible to change accessory with others, for example: the

automatic air vent, valve Cod.80 1/4 ", the group of overpressure Cod. SAT800, (See p. 12)

These SAT are mounted on sliding both horizontally and both

verticale that allows maximum comfort on installation.(see pag.13)

SAT501

SAT12

SAT12-2

SAT16

SAT16-2

SAT501

Page 8: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 8 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

SATELLITE SAT40_500_700. Composed by SAT40 (horizontal connection) with hot

sanitary water production,

SAT500 high temperature, with two connection and SAT700 low temperature with 5 connection, and overpressure unit.

It show the wide range of reachable unit of our system that allows different solutions

NOTE: connectiont to pipes is indicative. Standard connection

is with screwed nuts. Type and diameter of pipe used have to

be expressly indicated on the order. (see page 13)

Example of satellite of page 7 by inserting:

5 manifolds code 700F001X3-4GM4 with manual regulation lockshield,

5 valves code 700F001X3 / 4GM3 with manual adjustment.(see p. 13-14).

The encoding of the collectors specifies:

700 the characteristic of the body connections: double joint connections.

001 is 1”, the diameter of the body.

3-4” is the male screwed derivation for the connection of non screwed tube,

GM3 is the head of the valve, in this case is the manual regulation valve.

Otherwise you can install GM2 with electrothermal heads that can be controlled by a room thermostat .

Production and distribution of water at low temperature for

radiant panels. Consisting of: Adjustable thermostatic mixer D. 1 "with maximum temperature calibrated for the specific use.

Variable flow circulator class A. If the pump is not used, it is replaced by a threaded pipe. Two "T" junction on the supply and return, with two thermometers inserted. Flow regulation inserted on the return to the boiler.

Interception Valves, drain cocks and exhaust vents on the heads.

Two manifolds with flow meter and two with electrothermal regulation.

On demand is also possible installation of a manometer.

SAT521

SAT701

SAT721 Example of satellite SAT701 with the inclusion of 3 manifolds code

700F001X3-4GM4 equipped with adjustable flowmeter, and 3 manifolds

with manual adjustment code 700F001X3 / 4GM3. (see p. 13-14).

SAT30_700 Version SAT30, horizontal connection directly to the production of hot water at low temperature SAT700. With six manifolds, vent valves and manual drain cock on the heads.

SAT521

SAT711 Box with the manifolds for the distribution of low temperature heating.

The management module is inserted into the low temperature satellite SAT33, see p. 6. The user enters the number of manifolds of the series 700 in the desired number. (see p. 13 and 14). Each manifold occupies the space of 50 mm.

SAT711

SAT30-700

SAT40_500_700

SAT721

SAT701

Page 9: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 9 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

ELECTRONIC AND ELECTRICAL WIRING BOX

REDUCED ELETRONICAL CONTROL BOX

It can handle up to seven zones or different environments, each indicated by a LED that lights up when the circuit is activated. A LED indicates the presence of electric power and another the activation of the pump in the boiler room. The others the request of warm from the seven zone. Each of the seven commands is equipped with a timer that received the request pulse of heat from a room thermostat, activates the opening of electrothermal valve, but delay the activation pulse of the pump to allow the opening of the valve. The boxes are complete and need only be connected to the distribution network, to various external devices: thermostats or programmable thermostats installed in the rooms, pump and equipment in the boiler room, the thermoelectric valves when placed in a separate environment. The outputs of the cables are twelve, six on each side, watertight.

The box is arranged to directly manage one or two base zone. Each base zone controls a valve ball which distributes the heating fluid in his zone Each base zone can handle an unknown number of circuits, both at high and at low temperature. These sub zone are controlled by thermoelectric valves driven directly by thermostats.

The standard box is designed for the management of all the unit with any shape: basic unit, with management and distribution of high and low temperature heating.

Page 10: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 10 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

Loss of head diagramm of unit: SAT10, 20, 30, 40.— 3/4”

1 2 3 4 6 8 14-Tutta aperta KV - 2,2

“Z” version Straight version

The valve is equipped with a motor (with seal water proof IP65) which is operated by an electronic circuit (patented) that allows the user to program it in various ways: management of multiple entries or more outputs to choice. Possibility to use it as a mixing valve, etc.

In the standard version for satellites: heating, cooling, management or production of hot water. Valve connects alternately heating and hot sanitary water production. The request of hot sanitary water is a priority on the heating / cooling. As soon as the request ceased the valve switches to heating, if required. If the heating is turned off the valve switches on the production of hot sanitary water. Valve can be use for other applications, eg. as well as switch on the two sides also

close the entrance. Hydraulic characteristics: Full way bore, low pressure drop.

THREE OR FOUR WAYS ZONE VALVE TO MANAGE FLOW (PATENTED)

Valve is 3/4‖ PN25, supplied with F. connection (available also for different pipe connection)

FOUR FUNCTIONS: Interception, filter inspection, flow control, check valve. It is installed on the input of the primary fluid. Reduced space: full way with a very low loss of head, connections for: pro-be for calorie counter, draining and differential manometer. Draining valves and cocks for the differential pressure gauge. (optional)

VALVE CODE 820 (PATENTED)

Page 11: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 11 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

Heat meter: length 130 mm.— M.1‖ Male screwed ends.

Meter for sanitary water length 80 mm. Connections M. 3/4 " screwed ends.

COD. 655-656-HEAD ELECTROTHERMIC VALVE ON MANIFOLDS.

For the opening and closing of the fluid on the manifolds and valves.

They are normally closed and opened by an electrical impulse: by electronic controller, thermostats, programmable thermostats environment, etc ....

Close to an end of the impulse that has commanded the opening.

Valves and manifolds are supplied with manual control.

The head is delivered separately, you install it by unscrewing the nut of the manual control and screwing in place to head termoelettrica.

Technical features:

Normally closed. On request normally open.

230 V power supply (24V available)

Working power 3 W-opening time and closing ca. 3 min.

Force of closing 90 N - Nominal stroke 4 mm

Lenght of the connection cable 1 m.

Classe protection II Starting power consumption (<150ms): <1.2 A

Conform to CE standards.

Cod. 700-8 Manifold with manual control, prepared by the head thermoelectric 655-656,

COD. 700_6 MANIFOLD WITH FLOW REGULATOR AND WATER METER AND COVER PROTECTION AGAINST TAMPERING

TECHNICAL FEATURES:

Regulation quick and accurate without diagrams or other measurement tables or devices. The flow is displayed directly in l / min The adjustment can be locked and plunged against manipulations Control valve can be closed. Fluid temperature -10 + 70 ° C

Maximum operating pressure 6 bar Kvs value 1.1 m / h.

Measuring range 0 to 5.0 l / min.

HEAT AND SANITARY WATER COUNTERS

To avoid damage in the construction yard, valves of the collectors are normally delivered as follows.

The satellites are delivered with a extensiontube instead of the counter. The meters are delivered in their original packaging with manufacturer's seals You can also buy the satellites without the meters, and buy them later. In this case ask offer related.

To insert the meter just close the valve, unscrew the nuts, remove the socket, insert the counter, screw the nuts and connect it to the computer network. (See p. 3)

The CIV mounts normally counters SIEMENS and the offer of satellites includes these meters in version via twisted pair, M-BUS. But is available to mount other counters if preferred by the user

Page 12: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 12 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

Ball valves PN25, full bore - (Patented)

Loose nut on one side, connection to the pipes of polyethylene on the other

side.

By D. 1/2 "loose nut 3/4" pipe D. 20 to 11/2 ", loose nut 2" xD. tube 50.

Also available with screwed connections female or male, D. 1/2 "to 11/2"

700_4 Manifold with shut-off and flow control with micrometer screw. Protection cap in ABS. threads on leads: D. 1/2 " for pipes D. 10, 12, 14, 15 mm. D. 3/4" for pipes from D. 10 to 20 mm.

080 Automatic valve exhaust air. Safe, very small. Operating Temperature: from -10 to + 110 ° C. Connection on the thread with "O" R. Misure 1/4‖, 3/8‖, 1/2‖ (patent)

081A Manual valve exhaust air. Max pressure 10 bar. 081B Seal on the thread with PTFE ring. Thread 1/4 ", 3/8", 1/2 ".

2050 Ball valve drain. With hose and cap. 10 Bar pressure. Temperature -10 to 150 ° C. D. 1/2 "M.

108 Drain cock with connections for the differential pressure gauge, for the calibration circuits. Measure 1/4 "M.

6_SOVR - RELIEF VALVE

It is also provided with an angle body with the connections for screwed and unscreved pipes. Body, shutter, regulatory bodies: Brass EN 12165 CW617N. Spring, snap rings, stainless steel rod EPDM seals, for high temperature. Temperature 0-110 ° C, Max pressure 10 bar Setting range 1-10 meter of water. For medium: water, glycol solutions, max 30%. SETTING: Unscrew the brass cover, and turn the ring below. Each ride is about 1 m. overpressure.

362 - Ball Valves PN 40-Pass. total, for plastic and multilayer

pipes.

M. for the loose nut on one side, on the other Eurocone

For pipes with outer D. from 12 to 26 mm.

424 - Ball Valves PN. 40- Full bore, for plastic and multilayer pipes.

M. thread on one side, on the other side Eurocone

For pipes with outer D. from 12 to 26 mm.

D. valves 1/2 "- 3/4"

SAT800. Overpressure circuit for insertion in the head to the manifolds of SAT500 and SAT700. Composed of relief valve, drain cock, manual or automatic vent valves, ―T‖ for connection to the manifolds.

Page 13: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 13 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

METAL BOX .

HEAT EXCHANGER — brazed made in steel INOX Aisi 316 and copper

Dimension table, to refer to. (From ZILMET)

MODULAR MANIFOLDS (Patented)

The modular manifolds are equipped with a single derivation. Easily and quickly assembling and disassembling, until you reach the required number of connection. The type of interlocking causes the outside appears as a single collector and inside the passage is directed with a

1 2 3

COMPRESSION END FOR PIPES.

Primary flow side Secondary flow side (hot sanitary water)

Kcal/H N.

pia-

stre

flow

m3/h

speed

m/s

Inlet tempe-

rature,Gradi

C

Outlet tem-

perature

Gradi C

Loss of

head

mH2O

flow m3/

h

speed

m/s

Inlet tempe-

rature

Gradi C

Outlet tempe-

rature

Gradi C

Loss of head

m H2O

30.000 14 1,52 0,445 70 50 1,238 0,754 0,22 10 50 0,388

16.000 20 0,81 0,162 60 40 0,205 0,402 0,080 10 50 0,062

40.000 20 2,03 0,405 68 48 1,056 1,01 0,201 10 50 0,328

50.000 24 2,54 0,419 68 48 1,2 1,26 0,207 10 50 0,348

26.000 30 1,32 0,172 60 40 0,23 0,654 0,085 10 50 0,07

60.000 30 3,05 0,398 67,5 47,5 1,025 1,51 0,197 10 50 0,318

It allows the easy mounting and positioning of the equipment.

They are equipped with hardware sliding in all directions.

Standard height is 450 and 500, 630 mm.

lenght 500– 600-800– 1000– 1200 mm. The frame cover is adjustable and can rise up to 40 mm.

Are executed in galvanized steel sheet

The brackets on the sliding guides are coated with rubber.

Art. 61 69 66 65 67

Art. 61. For plastic tubes. Nut, spinner and male internal brass, "O" R. sealing EPDM rubber. Art. 69. For multilayer pipes. Nut, spinner and male internal brass, the three "O" R. sealing in EPDM, PTFE insulation gravel . Art. 66. For metal pipes. Nut, spinner, and possibly shortening internal pipes do D. lower brass,"O" R. Art. 65 e 67. For metal pipes. Nut, and warheads of EPDM rubber for art. 65, PTFE spinner to the art. 67.

1/2”- 12x 8 1/2”- 15x10 1/2”- 16x12 3/4”- 16x12 3/4”- 17x13 3/4”- 20x16

1/2”- 14X10 1/2”- 16X12 D24- 16X12 D24– 18x14 3/4”- 14X10 3/4”- 16X11,5 3/4”- 16X12 3/4”- 17X11,5 3/4”- 18X14 3/4”- 20X16 3/4”- 17X13 3/4”- 20X15 D.32– 26X20

ART. 61 ART. 69 D.

Dimensions: the first digit indicates the D. thread of the fitting, the two following the outside and inside diameter of the pipe.

ART 66 D. ART 67 D.

1/2”X10 1/2”X12 1/2”X14 1/2”X15 3/4”X12 3/4”X14 3/4”X16 3/4”X18

3/8”X10 1/2”X10 1/2”X12 1/2”X14 1/2”X15 1/2”X16 3/4”X12 3/4”X14 3/4”X15 3/4”X16 3/4”X18

Special sizes on request.

For fixing the plaster a galvanized wire mesh is attached to the rear part of the box

Page 14: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 14 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

1” simple manifold, male and female joint

simple manifold, 1” Screwed 1”male, female joint

1” simple manifold, Male screwed 1”- for “O”R - Female joint

1” simple manifold, Screwed 1” Female, Male joint

1” hand regulation manifold, male and female joint, for insertion between the heads of the account unit

1” manifold with flowmeter, male and female joint for insertion between the he-ads of the account

1” hand regulation manifold, Male screwed 1” Female joint

1” hand regulation Manifold. Female screwed 1” Male joint

Hand regulation manifold. Male screwed 1” for “O”R - Female joint

1” manifold with hand adju-stement. Female scre-wed 1” - Male joint

1” manifold wth hand adjustement Male screwed 1”- female joint

1” manifold with handd adjustement Male screwed 1” for “O”R - Female joint

1” manifold with flowmeter. Male screwed 1”- female joint

1” manifold with flowmeter. Female screwed 1” . Male joint

1” manifold with flowmeter. Male 1” for “O”R . Female joint

1” manifold with hand adjustement male and female joint. for insertion between the heads of the account unit

The leads are exposed with thread 3/4 "male (M) Eurocono,. But for diameter of tubes from 10 and 16 mm. there are also with 1/2‖ screw. The vertical column have the same body. The lines the same heads.

1” manifold Electrothermal head. male and female joint for insertion between the heads of the account unit

1” manifold Electrother-mal head Male screwed 1”. Female joint

1” manifold Electrother-mal head, Female screwed 1”, Male joint

1” manifold Electrothermal head Male screwed 1” for “O”R - Female joint

It is supplied with manual handle, same as GM3. Electrothermal heads N.655 or 656 is supplied separately (see page 11)

Manifolds for sanitary systems and more : M/F main inlet connection. Tightness with “O” R. in EPDM. 3/4”, 1”, 11/4” inlet connection. Connection 1/2” M/F . or 3/4” Eurokonus. Center to center distance 42 mm.

Art. 35 - Two connection. 3/4” 1” 11/4”

Art. 36 Three connection. 3/4” 1” 11/4”

Art. 37 Four connection. 3/4” 1” 11/4”

Art. 37 Five connection 3/4” 1” 11/4”

700F001X3-4GM1 701F001X3-4GM1 702F001X3-4GM1 705F001X3-4GM1

700F001X3-4GM3 701F001X3-4GM3 702F001X3-4GM3 705F001X3-4GM3

700F001X3-4GM4 701F001X3-4GM4 702F001X3-4GM4 705F001X3-4GM4

700F001X3-4GM2 701F001X3-4GM2 702F001X3-4GM2 705F001X3-

700F001X3-4GM6 701F001X3-4GM6 F001X3-4GM6 705F001X3-4GM6

Art. 45 With manual adjustement. Two connections.

Art. 44. With manual regulation. Two connections

Page 15: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 15 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

Manifold with electrothermal head Manifold with flowmeter Manifold with lockshield regulation

Thermostatic mixing valve . Blu line Ø. 3/4” M. Green line Ø. 1” M.

Heat meter. Q 0,6 e 1,5 mc/h thread 3/4” M Q 2,5 mc/h thread 1” M.

Hot sanitary water meter Q 1,5 mc/h thread 3/4” M. Q 2,5 mc/h thread 1” M.

LOSS OF HEAD DIAGRAMM - (nominal flow)

Page 16: MANAGEMENT OF HEATING AND AIR DI RICCARDO · PDF fileHEAT INTERFACE UNITS MANAGEMENT OF HEATING AND AIR CONDITIONING IN BUILDINGS Compact. mm. 430x460x125 depth, installable anywhere

ACCOUNT UNIT 16 CIRCUITI IDRAULICI E VALVOLE DI RICCARDO FERRERO

Area Ind. Piancerreto, 86/8 12060 FARIGLIANO (CN)

Tel.—Fax 0173 76171 Riccardo Ferrero Cell+ 39 335 60 07 386

E-mail [email protected] CCIA CUNEO N. 87371

MANUFACTURED IN ITALY CIV PRODUCE ON REQUEST ANY KIND OF "SATELLITES" AND HYDRAULIC CIRCUITS. MANUFACTURING OF PIPES WITH CNC CONTROLLED BENDING MACHINES.