maintenance & trouble shooting of voith coupling
TRANSCRIPT
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
1/20
1|Prsentation|JJJJ-MM-TT
Maintenance Measures With Unit Running
Daily:
Check the oil level in coupling.
Temperatures of bearings, lube oil & working oil
Lube oil and working oil pressures
Differential pressure on the lube oil filter
http://pictures/Front%20panel.JPG -
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
2/20
2|Prsentation|JJJJ-MM-TT
Maintenance Measures With Unit Running
Every 1000 hours of operation:
Check operating oil for contamination.(centrifuge if required)
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
3/20
3|Prsentation|JJJJ-MM-TT
Measure, record and compare smooth running (vibrations)under the same operating conditions.
In case of any problem, please check first the alignment.
Maintenance Measures With Unit Running
Every 3 months:
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
4/20
4|Prsentation|JJJJ-MM-TT
Maintenance Measures When the Unit is at
Standstill
Every 2 Months:
Clean vent filter.
Check smooth running of actuator.
Visually inspect gear stage.
Check operating oil for contamination.
Check oil level. In case of too high oil level, check for watercontent in the oil
http://pictures/Top%20view.JPG -
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
5/20
5|Prsentation|JJJJ-MM-TT
Maintenance Measures When the Unit is at
Standstill
Every 8000 hours of operation or at least annually:
Analyze operating oil for aging and other specifications.
Inspect and maintain connecting couplings. Check the actuator functioning. Check alignment and foundation fixing of hydraulic coupling. Visual inspection (corrosion, general condition etc) of hydraulic
coupling internals by removing inspection cover on top housing.
Visual inspection of tooth contact pattern. Inspection of fusible plugs. Check and maintain A.O.P. motor
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
6/20
6|Prsentation|JJJJ-MM-TT
Maintenance Measures When the Unit is at
Standstill
General Overhaul:
In the event of a change in operating behaviour or after maximum5 years operating time, variable speed & geared variable speedturbo coupling should be overhauled.
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
7/20
7|Prsentation|JJJJ-MM-
TT
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
8/20
8|Prsentation|JJJJ-MM-
TT
Trouble Cause(s) Action(s)1. Scoop tube in 0% position Move scoop tube in 100% direction.
2. Oil pump not delivering Check the oil level in the sump.any oil Check the direction
Check oil pump itself.
3. Starting torque too high. Check the driven machine itself.
Driven machine blocked.
Driven machine
cannot start afterthe drivingmachine hasreachedits rated speed
Start-upTROUBLE SHOOTING
http://pictures/svtl.exe -
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
9/20
9|Prsentation|JJJJ-MM-
TT
Trouble Cause(s) Action(s)
1. Driven machine is jammed. Remove obstacles.
(Check fusible plugs)
2. Oil flow too low Check oil flow
Coupling heats upexcessively duringstart-up
Start-upTROUBLE SHOOTING
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
10/20
10|Prsentation|JJJJ-MM
-TT
Trouble Cause(s) Action(s)
1. Lack of cooling water. Check cooling system.
Water is too warm Clean cooler.Cooler contaminated
2. Over loading of the coupling Check design data(Check fusible plugs)
Coupling heats upexcessively duringoperation
Start-up TROUBLE SHOOTING
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
11/20
11|Prsentation|JJJJ-MM
-TT
Trouble Cause(s) Action(s)1. Momentary fluctuations in the Check the system and stabilize.
driven machine.
2.Oil temperature is too low. Increase the temperature.(poor deaeration of oil) (45C to 50C)
3.Gear pump is aspirating air. Check oil level of sump.
Fluctuations of output
speed during manualcontrol of coupling(Control lever at standstill)
Output Speed TROUBLE SHOOTING
http://pictures/Output%20side.JPG -
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
12/20
12|Prsentation|JJJJ-MM
-TT
Trouble Cause(s) Action(s)1. Improper input signal to the Check the controller and
actuator. calibrate.
2 .Air entering into the oil circuit. Check and eliminate.
Fluctuations of output
speed during autocontrol of coupling(To & fro movement ofcontrol lever)
Output Speed TROUBLE SHOOTING
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
13/20
13|Prsentation|JJJJ-MM
-TT
Trouble Cause(s) Action(s)1. Scoop tube is jammed. Remove obstacles.
2. Actuator defective Check the actuator.
3. Input signal problem Check the controller.
Output speedcannot becontrolled
Output Speed TROUBLE SHOOTING
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
14/20
14|Prsentation|JJJJ-MM
-TT
Trouble Cause(s) Action(s)1. Scoop tube not in 100% Check the scoop tube position.
Position.
2. Fusible plugs responded Find and eliminate the cause.Insert new fusible plugs.
3. Too high power requirement Compare the power data with the
of driven machine project data.Check driven machinefor smooth running.
Max.Outputspeed cannotbe reached
Output Speed TROUBLE SHOOTING
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
15/20
15|Prsentation|JJJJ-MM
-TT
Trouble Cause(s) Action(s)1. Lube oil filter clogged Change over lube oil filter and clean
the filter element.
2. Leak in the oil circuits Check the pipe lines,coolers etc.
3. Improper orifice sizing. Correct the orifices.
Lube oilpressure is low
Pressures TROUBLE SHOOTING
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
16/20
16|Prsentation|JJJJ-MM
-TT
Trouble Cause(s) Action(s)
1. Lube oil filter clogged Change over lube oil filter and clean
the filter elements.
Differentialpressure acrossdouble oil filtertoo high
Pressures TROUBLE SHOOTING
http://pictures/Rear%20panel-filters.JPG -
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
17/20
17|Prsentation|JJJJ-MM
-TT
Trouble Cause(s) Action(s)Lube oil Cooler Problem1. Cooling water flow rate too low Increase the cooling water flow rate2.Cooling water too warm
3.Cooler is contaminated
Check and clean the cooling system
1.Fusible plugs responded Find and eliminate the cause.Insertnew fusible plugs.
Lube oil temperaturetoo high downstream
of lube oil cooler
Temperatures TROUBLE SHOOTING
Lube oil temperaturetoo high upstream oflube oil cooler
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
18/20
18|Prsentation|JJJJ-MM
-TT
Trouble Cause(s) Action(s)Temperatures TROUBLE SHOOTING
Bearing temperaturetoo high
1. Bearing damage Check the bearings and replace.
2. Lube oil temperature too high Check the lube oil cooler.
3.Lube oil pressure too low Check the lube oil system anddifferential pressure.
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
19/20
19|Prsentation|JJJJ-MM
-TT
Trouble Cause(s) Action(s)1.Faulty alignment Check and correct alignment.
2.Foundation bolts are loose, Check the foundation and retightenthe foundation is defective the foundation bolts.
3. Wear or insufficient lubrication Check the connecting couplings.of connecting couplings
4. Unbalance of rotating parts Measure the vibration and check therunner parts.
5.Bearing damage Check and replace bearings.
Smooth RunningTROUBLE SHOOTING
Uneven running,vibration andnoise
-
8/3/2019 Maintenance & Trouble Shooting of Voith Coupling
20/20
20|Prsentation|JJJJ-MM
-TT