Maintenance Experience
Bimonthly for Data Products
No.13 Issue 160, April 2009
In this issue of ZTE's Maintenance Experience, we continue
to pass on various eld reports and resolutions that are gathered
by ZTE engineers and technicians around the world.
The content presented in this issue is as below:
One Special Document
Six Maintenance Cases of ZTE's Data Products
Have you examined your service polices and procedures
lately? Are you condent that your people are using all the tools
at their disposal? Are they trained to analyze each issue in a
logical manner that provides for less downtime and maximum
customer service? A close look at the cases reveals how to iso-
late suspected faulty or mis-congured equipment, and how to
solve a problem step by step, etc. As success in commissioning
and service is usually a mix of both discovery and analysis, we
consider using this type of approach as an example of success-
ful troubleshooting investigations.
While corporate leaders maintain and grow plans for expan-
sion, ZTE employees in all regions carry out with individual ef-
forts towards internationalization of the company. Momentum
continues to be built, in all levels, from ofce interns to veteranengineers, who work together to bring global focus into their
daily work.
If you would like to subscribe to this magazine (electronic
version) or review additional articles and relevant technical mate-
rials concerning ZTE products, please visit the technical support
website of ZTE Corporation (http://ensupport.zte.com.cn).
If you have any ideas and suggestions or want to offer your
contributions, you can contact us at any time via the following
email: [email protected].
Thank you for making ZTE a part of your telecom experience!
Maintenance Experience Editorial Committee
ZTE Corporation
April, 2009
Director: Qiu WeizhaoDeputy Director: Chen Jianzhou
Editors:
Jiang Guobing, Zhang Shoukui, Wu Feng, Yuan
Yufeng, Tang Hongxuan, Li Gangyi, Song Jianbo,
Tian Jinhua, Wang Zhaozheng, Liu Wenjun,
Wang Yapping, Lei Kun, Wang Tiancheng,
Ge Jun, Yu Qing, Zhang Jiebin, Fang Xi
Technical Senior Editors:
Hu Jia, Bai Jianwen
Executive Editor:
Zhang Fan
-
8/2/2019 Maintenance Experience Issue160(Data Products)
3/32
-
8/2/2019 Maintenance Experience Issue160(Data Products)
4/32
Maintenance Experience2
April 2009 Issue 160
NetNumen N31 Overview
At present, network techniques de-
velop vigorously. More and more key ap-
plications and services are established on
the base of data network. Therefore, it is
very important to ensure that the network
works normally and efficiently. Network
operators, Internet service providers and
enterprises must implement effective man-
agements and plans to the network system
to meet the growing requirements of users
to the maximum extent. To establish, de-
ploy and use the network quickly, as well
as keep the network running conveniently,
a data network management system with
powerful functions, good extensibility and
high performance is recommended.
On the other hand, due to the fast
changing market, declining product life
cycle and increasing market launch press,
network operators are facing intense com-
petition. Therefore, requirement of effec-
tive network management system is need-
ed in order to decrease operating cost and
improve network quality.
In addition, considering the increasing
software development cost and demand
for supporting different operating systems
and hardware platforms, network opera-
tors have to nd a technique that can help
them to improve productivity greatly. In
NetNumen N31 Unied
Management System Ye Dezhong, Lu yinghua / ZTE Corporation
the current situation, technique and demand keepschanging continually. It is important for most equip-
ment manufacturers and software developers to
make their product support different operating
systems and hardware platforms. To meet the
changing requirements of their users, equipment
manufacturers must provide a network manage-
ment system that can run in different platforms and
support Web.
ZTE holds the pulse of the times and develops
NetNumen N31 Unied Management System. This
is a high customization cross-platform network
management system of carrier class. It is on the
base of new Internet technique and it is designed
according to rules from bottom to top. It can be
used to manage all ZTE data products. It covers
network element management, network manage-
ment and service management.
NetNumen N31 Functions
NetNumen N31 has the following functions.
1. Providing unied network management.
NetNumen N31 can be used to manage all
ZTE data products.
NetNumen N31 covers Management levels
of network element, network and service,
providing perfect network management
functions.
NetNumen N31 can be integrated with
network management systems of NGN and
ADSL to implement unied management.
Key words:NetNumen N31
-
8/2/2019 Maintenance Experience Issue160(Data Products)
5/32
Data Products
www.zte.com.cn
3
2. Providing different management privileges
and implementing management in different areas.
Users can access the management system in dif-
ferent areas with different management privileges.
3. Supporting different platforms and different
databases.
NetNumen N31 uses J2EE architecture
and it is developed in JAVA. Therefore it
supports different platforms and operating
sys tems such as UNIX, LINUX and
WINDOWS.
NetNumen N31 supports databases such
as MSSQL, SYBASE and ORACLE.
4. Providing convenient extension and up-
grade.
NetNumen N31 uses modularization structure.
It is with good extension and upgrade ability.
5. Providing special management functions.
Policy management
Fast network automatic discovery
Fault processing expert base
Report processing
Conguration management based on task
Network statistics6. Supporting localization.
NetNumen N31 supports Chinese and English.
Users can select the language during the installa-
tion to implement localization management.
7. Complying with high standards
NetNumen N31 complies with TMN series sug-
gestions defined by ITU-T. NetNumen N31 also
complies with a series of network management
protocols defined in RFC and network manage-
ment suggestions in TMF.
8. Providing high security.
NetNumen N31 provides perfect access
privilege control.
NetNumen N31 provides perfect security
log records.
9. Providing high reliability.
NetNumen N31 supports local backup and
remote recovery.
NetNumen N31 is with good fault tolerance
ability. When a server in the system
is down, other servers can take
over the tasks. This ensures that
the services will not be intermitted.
NetNumen N31 provides good
system management ability. Data
information of NetNumen N31
management sys tem can be
monitored.
10. Providing good openness.
NetNumen N31 supports standard
SNMP and it provides CORBA interface,
SNMP interface and TL1 interface. NetNu-
men N31 can be integrated with third party
systems, providing convenience for ofces
to implement OSS system application.
11. Providing perfect after sale ser-
vice.
NetNumen N31 uses are provided with
247 after sale service of ZTE.
The management functions of NetNu-
men N31 management system cover four
layers of TMN management layers, includ-
ing Network Element (NE) layer, NE man-agement layer, network management layer
and service management layer. The core
is the function modules in network man-
agement layer. The structure of NetNumen
N31 management system is shown in
Figure 1.
Figure 1. Structure of NetNumen N31 Management System
-
8/2/2019 Maintenance Experience Issue160(Data Products)
6/32
-
8/2/2019 Maintenance Experience Issue160(Data Products)
7/32
Data Products
www.zte.com.cn
5
Malfunction Situation
When users install SQL, the system may usually prompt installation failure. The reason is that
users have installed database before but the database les were not deleted completely.
Solution
To delete the database les completely, perform the following steps.1. Uninstall the database program through Add orRemove Programs in Control Panel.
2. Delete the whole Microsoft SQL Server le manually.
3. Click StartRun and input regedit to open RegistryEditor, and then delete the follow-
ing items.
HKEY_CURRENT_USER\Software\Microsoft\Microsoft SQL Server
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Microsoft SQL Server
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\MSSQLServer
4. Reboot the system.
5. Install SQL again.
SQL Server Installation Failure Wang Xinlin / ZTE Corporation
Key words: SQL, installation failure
-
8/2/2019 Maintenance Experience Issue160(Data Products)
8/32
Maintenance Experience6
April 2009 Issue 160
Malfunction Situation
ZXR10 2818S switches work as mem-
ber switches in a cluster. As shown inFigure 1, switches are displayed as CO
in NetNumen N31 network management
platform. However, in normal situation,
switches must be displayed as C. When
switches are displayed as CO, there is no
telnet option in the shortcut menu if users
right-click the switches.
Member Switch in Cluster
Displaying as CO Zhang Jintao / ZTE Corporation
switch or an external member switch of the cluster.
An internal member switch of a cluster
appears in both Device table and Group
member table.
An external member switch of a cluster
appears only in Device table but not in
Group member table.
Sometimes, users may find that a switch ap-
pears both in Device table and Group member ta-
ble, but it is displayed as CO on network manage-
ment server. The reason is that that switch worked
as a member switch, the link between the member
switch and the command switch was down and a
moment later it was recovered, but states on the
command switch was not refreshed. Users are
recommended to implement topology collection to
refresh the state on the command switch.
Solution
To solve the problem, perform the following
steps.
1. Delete the member switches on the com-
mand switch and then add the member switches
again. This ensures that the state of member
switches in Group member table is up and users
can log in to member switches through command
switch.
2. Input ztp start command on command
switch to collect topology information again.
3. Right-click the command switch in topol-
ogy management view and then select Update
State in the shortcut menu. The member switches
are displayed as C.
Figure 1. Member Switch in Cluster Displaying as CO
Malfunction Analysis
When the switch is displayed as C, it is
an internal member switch of the cluster.
When the switch is displayed as CO, it isan external member switch of the cluster.
In a switch cluster, there are two impor-
tant tables on the command switch, Device
table and Group member table. Users can
view the information in the two tables with
show ztp device-list command and show
group membercommand.
The following rules are used to judge
whether a switch is an internal member
Key words: cluster management, CO, C, ZTP, NetNumen N31
-
8/2/2019 Maintenance Experience Issue160(Data Products)
9/32
Data Products
www.zte.com.cn
7
Malfunction Situation
There are two NEs (ZXR10 T64G) with
the same name Miriyalguda in NetNu-
menN31 network management system.
They are in different groups, as shown in
Figure 1.
NE MAC Address Collision Zhou Hongwei / ZTE Corporation
address collision.
Engineers logged into the two NEs and
checked the MAC addresses. Engineers found that
the MAC address were the same indeed. The MAC
address was 00d0.d0c7.ffe1, as shown in Figure 2.
Figure 1. Same NEs
Figure 2. MAC Address
Malfunction Analysis
Engineers checked the information
of the NEs. The NEs had the same infor-
mation, including IP address. Engineers
considered that it may be caused by MAC
Solution
The same MAC address on two NEs resulted
in the MAC address collision in NetNumenN31
network management system. Therefore, it was
Key words: NetNumenN31, MAC address collision
-
8/2/2019 Maintenance Experience Issue160(Data Products)
10/32
Maintenance Experience8
April 2009 Issue 160
necessary to modify the MAC address in
one of the NEs.
To modify the MAC address on one
NE through remote connection, engineers
took the following steps.
1. Engineers defined an address
segment range on service interface of the
switch with the following command.
ZXR10(config-increte)#mac-base-addr
add master / slave { 8 |
16 | 32 }
8, 16 and 32 were used to specify the
MAC address range. If the MAC address
range was set as 8, the last three bits of
MAC address must be 0. If the MAC ad-
dress range was set as 16, the last four
bits of MAC address must be 0. If the MAC
address range was set as 32, the last ve
bits of MAC address must be 0.
After dening address segment range
on service interface, engineers input the
following command.
ZXR10(config-increte)#mac-base-addr
enable master/slave
After this command was configured,
MAC address was distributed in new mode
and it was saved in nvram of the switch.
After the switch was rebooted, the new
MAC address distribution mode would beloaded in memory and take effect.
2. Engineers defined an address
segment range on administration interface
of the switch with the following command.
ZXR10(config-increte)#mac-base-addr add
master/slave mng { 1-4 }
At present, four MAC address could be speci-
ed on administration interface. However, only one
administration interface was needed on G series
switches. Therefore it was necessary to congure
one MAC address. It was not necessary to set the
MAC address for administration interface according
to the address segment range dened on service
interface.
After defining address segment range on ad-
ministration interface, engineers input the following
command.
ZXR10(config-increte)#mac-base-addr enable
master/slave
After this command was configured, MAC ad-
dress was distributed in new mode and it was
saved in nvram of the switch. After the switch was
rebooted, the new MAC address distribution mode
would be loaded in memory and take effect.
3. Engineers saved the above conguration.
It was not necessary to save the conguration
manually. After the configuration, the above com-
mands were saved in nvram of the switch automat-
ically. They would take effect after the switch was
rebooted.
The above configuration also could be saved
manually with the following command.
ZXR10# write nvram
-
8/2/2019 Maintenance Experience Issue160(Data Products)
11/32
Data Products
www.zte.com.cn
9
Malfunction Situation
After the software version of T160G in a city
is upgraded, services running on a DSLAM con-
nected to this T160G were interrupted and it failed
to access NMS of the DSLAM. T160G provides L2
transparent transmission for services of DSLAM.
NMS of DSLAM and that of T160G were in the
same network segment.
The network topology is shown in Figure 1.
tion was normal.
2. Engineers viewed MAC entries of
T160G and they found that MAC address
learning was normal, as shown below.
T160G#show mac interface fei_3/43
Total MAC address : 96
Flags: vid -VLAN id,stc-static, per-permanent, toS-to-
static, srF-source lter,dsF-destination lter,time-day:hour:min:sec Frm-mac from where:0,drv:1,cong:2,V
PN:3,802.1X:4,micro:5,dhcp
MAC_Address port vid stc per toS srF dsF Frm Time---------------------------------------------------------------------------------------0014.6c24.acf3 fei_3/43 123 0 0 0 0 0 0 0:01:06:30
0810.170c.551f fei_3/43 123 0 0 0 0 0 0 0:01:14:42
00e0.fc0e.4fe2 fei_3/43 6 0 0 0 0 0 0 0:01:05:40
Figure 1. Network Topology Diagram
Malfunction Analysis
To nd out the problem, engineers took the fol-
lowing steps.
1. Engineers viewed alarm log of T160G and
they found that there was no problem. All informa-
3. Engineers viewed ARP informa-
tion of T160G. They found that ARP infor-
mation of peer DSLAM could be learned.
IP address of DSLAM was 221.9.122.6, as
shown below.
T160G#show arp int vlan 6
Arp protect mac is disabled
The count is 2
IPAddress Age(min) HardwareAddress VLAN InterfaceID SubInterface-----------------------------------------------------------------------------------------221.9.122.6 0 00e0.fc0e.4fe2 vlan6 6 fei_3/43
221.9.122.5 - 00d0.d0c0.5721 vlan6 N/A N/A
Key words: network interruption, MAC address offset
Network Interruption Caused byMAC Address OffsetNetwork Interruption Caused byMAC Address Offset Ye Wei / ZTE Corporation
-
8/2/2019 Maintenance Experience Issue160(Data Products)
12/32
Maintenance Experience10
April 2009 Issue 160
4. Engineers viewed direct-connect-
ed route 221.9.122.6. The entries in hard-
ware forwarding table were correct, as
shown below.
T160G#sho ip forwarding hostrt np 3 221.9.122.6
Host routing table:
Flags:Int-internal label,Ext-external label,Tr-trunk ag,
Mf-mpls ag,Vpn-vpn id,
Loc-location(SW--switch,NP--network processer)
IpAddr/Mask Mod/Port Vlan/Tag Int/Ext DestMac Tr/Mf/Vpn/Loc-------------------------------------------------------------------------------------221.9.122.6/32 3/43 6/1 untagged 00e0.fc0e.4fe2 0/0/0/SW
5. Engineers pinged to NMS address of
DSLAM through T160G, as shown below.
T160G#ping 221.9.122.6
sending 5,100-byte ICMP echos to
221.9.122.6,
timeout is 2 seconds.
.....
Success rate is 0 percent(0/5).
T160G#sho mac int gei_2/4
Total MAC address : 27
Flags: vid-VLAN id,stc-static,per-permanent,toS-to-static,srF-source lter,dsF-destination lter,time-day:hour:min:sec
Frm-mac from where:0,drv;1,cong;2,VPN;3,802.1X;4,micro;5,dhcp
MAC_Address port vid stc per toS srF dsF Frm Time-----------------------------------------------------------------------------------------------00e0.fc5d.09c0 gei_2/4 196 0 0 0 0 0 0 0:02:58:08
00e0.fc5d.09c0 gei_2/4 166 0 0 0 0 0 0 0:03:00:40
00e0.fc5d.09c0 gei_2/4 55 0 0 0 0 0 0 0:12:31:08
00e0.fc5d.09c0 gei_2/4 194 0 0 0 0 0 0 0:00:18:13
00e0.fc5d.09c0 gei_2/4 105 0 0 0 0 0 0 0:09:32:49
00e0.fc5d.09c0 gei_2/4 193 0 0 0 0 0 0 0:12:39:22
00e0.fc5d.09c0 gei_2/4 121 0 0 0 0 0 0 0:12:39:25
00e0.fc5d.09c0 gei_2/4 104 0 0 0 0 0 0 0:12:39:25
00e0.fc5d.09c0 gei_2/4 165 0 0 0 0 0 0 0:12:39:25
00e0.fc5d.09c0 gei_2/4 167 0 0 0 0 0 0 0:12:39:24
00e0.fc5d.09c0 gei_2/4 178 0 0 0 0 0 0 0:12:39:26
00e0.fc5d.09c0 gei_2/4 198 0 0 0 0 0 0 0:12:39:26
00e0.fc5d.09c0 gei_2/4 123 0 0 0 0 0 0 0:12:39:26
6. Engineers viewed MAC address
learning on T160G interface connected
to HW5200G. MAC address learning was
normal, as shown below.
-
8/2/2019 Maintenance Experience Issue160(Data Products)
13/32
Data Products
www.zte.com.cn
11
The above fault information showed that MAC
address learning on T160G was normal and few
forwarding entries and ARP learning were also
correct. While after upgrade, services and NMSs
of the other DSLAM devices were normal. This
indicated that it was not the problem of T160G.
After the upgrade, fault occurred and the difference
before and after upgrade was that MAC address of
T160G offsets for one bit. It was supposed that IP
address and MAC address of T160G were bound
in DSLAM.
Solution
Engineers checked configuration of DSLAM.
They found that MAC binding was not set and the
learnt MAC address was the old MAC ad-
dress of T160G. Due to software problem,
MAC learning and address aging func-
tion of DSLAM got invalid. After rebooting
DSLAM, services ran normally.
Experience Summary
After upgrade, MAC address of T160G
changed and the faulty DSLAM happened
to have problem in MAC learning (MAC
address aging function and MAC learn-
ing got invalid), which brought interruption
of services. After engineers reboot theDSLAM, MAC address learning function
restored and services ran normally.
-
8/2/2019 Maintenance Experience Issue160(Data Products)
14/32
Maintenance Experience12
April 2009 Issue 160
Network Topology
DSLAM and switches are down-linked
to 3952. SVLAN is configured on 3952.
Transparent transmission is congured on
T64G. Leased-line users, NM and other
services are terminated on T64E. PPPOE
dial-in users are terminated on BAS. Net-
work topology is shown in Figure 1.
Surng Internet in MAN Ye Wei / ZTE Corporation
The range of inner vlan id for PPPOE dial-in
user: for DSLAMs, 100 vlans are allocated
to each device with id range to be 101-500;
for switches, 40 vlans are allocated to each
device with id range to be 501-2500.
Malfunction Situation
The speed of surng internet at peak hours was
slow. Delay in sending ping packet was high, and
some packets were lost. At this peak time devices
ran normally, and other operational functions of the
devices was normal.
Malfunction Analysis
To nd out the problem, engineers took the fol-
lowing steps.
1. Engineers viewed system CPU utilization
when the speed of surfing internet was slow to
make sure whether CPU utilization was too high to
inuence running of system. The result was shown
below.
Figure 1. Network Topology
The planning of VLAN is as follows:
Leased line: 3001-3500
Network management system: 99
The range of outer vlan id for
PPPOE dial-in user: 100
Key words: QinQ, VLAN, uplink port, customer port
-
8/2/2019 Maintenance Experience Issue160(Data Products)
15/32
Data Products
www.zte.com.cn
13
The above information showed that the CPU
was normal.
2. Engineers viewed traffics on interface.
Traffics on port may also influence the speed ofsurng internet. If the trafcs were too large, con-
gestion would occur, and then the speed of surng
internet could also be slowed down. Interface trafc
information is shown below.
ZXR10#show interface fei_1/1
fei_1/1 is up, line protocol is up
Description is none
Keepalive set:10 sec
The port is electricDuplex full
Mdi type:auto
VLAN mode is access, pvid 4094 BW 100000
Kbits
Last clearing of "show interface" counters never
120 seconds input rate: 3403245 Bps, 3117 pps
120 seconds output rate: 1122389 Bps, 11912
pps
Interface peak rate:
input 8120382 Bps, output 12420382 BpsInterface utilization: input 29%, output 90%
Input:
Packets: 19028174612 Bytes: 24122478262892
Unicasts: 18709469101 Multicasts: 19281980
Broadcasts: 299188371 Undersize: 230911
Oversize: 3247 CRC-ERROR: 9
Dropped: 1091 Fragments: 0
Jabber: 1002 MacRxErr: 0
Output:
Pack e t s : 142123550101 By t e s :
182329420262394
Unicasts: 56909126342 Multicasts:
729262387
Broadcasts: 84485161372 Collision: 0
LateCollision: 0
Total:
64B: 772661029 65-127B: 803872612
128-255B: 1292984228 256-511B:
2374859862
512-1023B: 63467072821 1024-1518B:
92427412536
The above information showed that
trafcs on customer port in outgoing direc-
tion were large and it caused congestion.
Engineers viewed traffic information on
other interfaces. They found that trafcs in
outgoing direction of other interfaces were
also large.
3. Engineers viewed traffics on up-
link interface, as shown below.
ZXR10#show interface gei_2/1
gei_2/1 is up, line protocol is up
Description is none
Keepalive set:10 sec
The port is electric
Duplex full
Mdi type:auto
VLAN mode is access, pvid 4094 BW
ZXR10#show processor
M: Master processor
S: Slave processor
Peak CPU: CPU peak utility measured in 2 minutes
PhyMem: Physical memory (megabyte)
Panel CPU(5s) CPU(30s) CPU(2m) Peak CPU PhyMem Buffer Memory
MP(M) 1 20% 19% 18% 40% 256 0% 35.902%
-
8/2/2019 Maintenance Experience Issue160(Data Products)
16/32
Maintenance Experience14
April 2009 Issue 160
1000000 Kbits
Last clearing of "show interface" coun-
ters never120 seconds input rate : 29123012 Bps,
29081 pps
120 seconds output rate: 14133829 Bps,
13909 pps
Interface peak rate :
input : 50234251 Bps, output 5292182
Bps
Interface utilization: input 28%, output
19%
The above information showed that
trafcs on uplink port were normal.
4. Engineers viewed alarm informa-
tion. No abnormal alarm was presented
and no MAC floating alarm occurred.
Therefore, it was not loop that caused
broadcast storm.
5. Engineers analyzed configuration
on the device. QinQ conguration is shown
below.
Port conguration is shown below.
ZXR10(cong)#show run interface fei_1/1
description TO-DS01
no negotiation auto
switchport mode hybrid
switchport hybrid native vlan 4094
switchport hybrid vlan 99 tag
switchport hybrid vlan 100 untag
switchport hybrid vlan 3001-3010 tag
switchport qinq customer
ZXR10(cong)#show run interface fei_1/2
description TO-DS02
no negotiation auto
switchport mode hybrid
switchport hybrid native vlan 4094
switchport hybrid vlan 99 tag
switchport hybrid vlan 100 untag
switchport hybrid vlan 3011-3020 tag
switchport qinq customer
ZXR10(cong)#show run interface fei_2/1
description to-T64G
no negotiation auto
hybrid-attribute ber
switchport mode hybrid
switchport hybrid native vlan 1
switchport hybrid vlan 99 tag
switchport hybrid vlan 101-150 tag
switchport hybrid vlan 3001-3500 tag
switchport hybrid vlan 501-2500 tag
switchport hybrid vlan 4094 untag
switchport qinq uplink
ZXR10(cong)#show vlan qinq
Session Customer Uplink In_Vlan Ovlan Helpvlan
-------------------------------------------------------------------
1 fei_1/1 gei_2/1 101-200 100
2 fei_1/2 gei_2/1 201-300 100
3 fei_1/3 gei_2/1 301-400 100
4 fei_1/4 gei_2/1 401-500 100
5 fei_1/5 gei_2/1 501-540 100
6 fei_1/6 gei_2/1 541-580 100
-
8/2/2019 Maintenance Experience Issue160(Data Products)
17/32
Data Products
www.zte.com.cn
15
Malfunction Situation
As shown in Figure 1, ACL
was applied on interface Fei_1/1
of ZXR10 3928 switch to forbid
PC to ping to 3928. The congu-
ration failed but still PC could
ping 3928 successfully.
With the above information results, engineers
found that native VLAN on each port was Helperv-
lan 4094. Double-tagged services were implement-
ed through VLAN QinQ. Therefore, MAC learning
was in Helpervlan 4094, and the VLAN 100 would
not learn MAC addresses. That is, packets in VLAN
100 were broadcasted to downstream devices.
After asking the ofce personnel about services
running, engineers knew that that there were a lot
of double-tagged PPPOE services that were trans-
parently transmitted.
According to the plan, users were identied by
inner tags and areas were identied by outer tags.
Therefore, PPPoE service on ZXR10 3952 was
only allocated with one outer tag vlan 100,
and all ports were in this vlan.
From above information, downstream
PPPOE trafcs were broadcasted in VLAN
100. Since the uplink port was 1000M and
the downstream traffics were great, but
customer port was 100M, downstream
broadcast traffics were congested. This
made internet surng slow.
Solution
Engineers set the outer tag VLAN id
to native VLAN id on customer port. Theproblem was solved.
Figure 1. Network Topology
Key words: ACL, ping, protocol protection
Operational Failure through ACLOperational Failure through ACL Zhang Fan / ZTE Corporation
-
8/2/2019 Maintenance Experience Issue160(Data Products)
18/32
Maintenance Experience16
April 2009 Issue 160
Malfunction Analysis
Engineers checked configuration of
ZXR10 3928 switch, as shown below.
acl extend number 101
rule 1 deny icmp 10.40.184.0 0.0.3.255
any
rule 2 permit ip any any
!
int fei_1/1
protpcol-protect mode icmp disable
switchport access vlan 1
ip access-group 101 0 in
The command to apply ACL is shown
below:
ip access-group in
In this command, parameter is required. The value is 0 or 1.
0 indicates that protocol protection is en-
abled and 1 indicates protocol protection
is disabled. Protocol protection is enabledby default on interface, that is, the default
value of is 0.
After protocol protection function was
enabled, switch improved priority of ICMP
packets through a set of special rules.
These rules were placed ahead of ACL.
ICMP was in protocol protection range.
Protocol protected packet had a higher pri-
ority than ACL. As the value of parameter
on ZXR10 3928 switch was 0 by
default, the command of disabling ICMP became
invalid. As a result, PC could still ping to ZXR10
3928 switch successfully.
Solution
Engineers modied the conguration of ZXR10
3928 switch, as shown below.
acl extend number 101
rule 1 deny icmp 10.40.184.0 0.0.3.255 any
rule 2 permit ip any any
!int fei_1/1
protpcol-protect mode icmp disable
switchport access vlan 1
ip access-group 101 1 in //Set the value of pa-
rameter profile-number to 1, that is, protocol-
protect is disabled
Experience Summary
For downlink interface where SVLAN is en-
abled, the value of parameter
must be 1. When protocol protection is enabled,
the value of parameter must be 0.
When a switch is used as L2 device, then value
of parameter is allowed to be 1.
However, in this situation, some control packets
will fail to be received on the interface and some
protocol calculations will be wrong. Therefore, set
the value of parameter to 0.
-
8/2/2019 Maintenance Experience Issue160(Data Products)
19/32
Data Products
www.zte.com.cn
17
Network Topology
DSLAM and switches are down-linked to 3952.
SVLAN is congured on 3952. Transparent trans-
mission is congured on T64G. Leased-line users,NM and other services are terminated on T64E.
PPPOE dial-in users are terminated on BAS. Net-
work topology is shown in Figure 1.
Surng Internet in MAN Ye Wei / ZTE Corporation
some packets were lost. At this peak time
devices ran normally, and other operation-
al functions of the devices was normal.
Malfunction Analysis
To nd out the problem, engineers took
the following steps.
1. Engineers viewed system CPU
utilization when the speed of surfing in-
ternet was slow to make sure whether
CPU utilization was too high to influence
running of system. The result was shown
below.
Figure 1. Network Topology
ZXR10#show processor
M: Master processor
S: Slave processor
Peak CPU: CPU peak utility measured in 2 minutes
PhyMem: Physical memory (megabyte)
Panel CPU(5s) CPU(30s) CPU(2m) Peak CPU PhyMem Buffer Memory
MP(M) 1 20% 19% 18% 40% 256 0% 35.902%
The above information showed that the
CPU was normal.
2. Engineers viewed trafcs on inter-
face. Traffics on port may also influence
the speed of surng internet. If the trafcs
were too large, congestion would occur,
and then the speed of surfing internet
could also be slowed down. Interface traf-
c information is shown below.
The planning of VLAN is as follows:
Leased line: 3001-3500
Network management system: 99
The range of outer vlan id for PPPOE dial-in
user: 100
The range of inner vlan id for PPPOE dial-in
user: for DSLAMs, 100 vlans are allocated
to each device with id range to be 101-500;
for switches, 40 vlans are allocated to each
device with id range to be 501-2500.
Malfunction Situation
The speed of surng internet at peak hours was
slow. Delay in sending ping packet was high, and
Key words: QinQ, VLAN, uplink port, customer port
-
8/2/2019 Maintenance Experience Issue160(Data Products)
20/32
Maintenance Experience18
April 2009 Issue 160
ZXR10#show interface fei_1/1
fei_1/1 is up, line protocol is up
Description is noneKeepalive set:10 sec
The port is electric
Duplex full
Mdi type:auto
VLAN mode is access, pvid 4094 BW
100000 Kbits
Last clearing of "show interface" coun-
ters never
120 seconds input rate: 3403245 Bps,
3117 pps
120 seconds output rate: 1122389 Bps,
11912 pps
Interface peak rate:
input 8120382 Bps, output 12420382
Bps
Interface utilization: input 29%, output
90%
Input:
P a c k e t s : 1 9 0 2 8 1 7 4 6 1 2 B y t e s :
24122478262892
Unicasts: 18709469101 Multicasts:19281980
Broadcasts: 299188371 Undersize:
230911
Oversize: 3247 CRC-ERROR: 9
Dropped: 1091 Fragments: 0
Jabber: 1002 MacRxErr: 0
Output:
Pack e t s : 142123550101 By t e s :
182329420262394
Unicasts: 56909126342 Multicasts:
729262387
Broadcasts: 84485161372 Collision: 0
LateCollision: 0
Total:
64B: 772661029 65-127B: 803872612
128-255B: 1292984228 256-511B:
2374859862
512-1023B: 63467072821 1024-1518B:
92427412536
The above information showed that trafcs on
customer port in outgoing direction were large and
it caused congestion. Engineers viewed traffic in-
formation on other interfaces. They found that traf-
fics in outgoing direction of other interfaces were
also large.
3. Engineers viewed traffics on uplink inter-
face, as shown below.
ZXR10#show interface gei_2/1
gei_2/1 is up, line protocol is up
Description is none
Keepalive set:10 sec
The port is electric
Duplex full
Mdi type:auto
VLAN mode is access, pvid 4094 BW 1000000 Kbits
Last clearing of "show interface" counters never
120 seconds input rate : 29123012 Bps, 29081 pps
120 seconds output rate: 14133829 Bps, 13909 pps
Interface peak rate :
input : 50234251 Bps, output 5292182 Bps
Interface utilization: input 28%, output 19%
The above information showed that trafcs on
uplink port were normal.
4. Engineers viewed alarm information. No
abnormal alarm was presented and no MAC oat-
ing alarm occurred. Therefore, it was not loop that
caused broadcast storm.
5. Engineers analyzed configuration on the
device. QinQ conguration is shown below.
ZXR10(cong)#show vlan qinqSession Customer Uplink In_Vlan Ovlan Helpvlan----------------------------------------------------1 fei_1/1 gei_2/1 101-200 100
2 fei_1/2 gei_2/1 201-300 100
3 fei_1/3 gei_2/1 301-400 100
4 fei_1/4 gei_2/1 401-500 100
5 fei_1/5 gei_2/1 501-540 100
6 fei_1/6 gei_2/1 541-580 100
-
8/2/2019 Maintenance Experience Issue160(Data Products)
21/32
Data Products
www.zte.com.cn
19
Port conguration is shown below.
ZXR10(cong)#show run interface fei_1/1
description TO-DS01
no negotiation auto
switchport mode hybrid
switchport hybrid native vlan 4094
switchport hybrid vlan 99 tag
switchport hybrid vlan 100 untag
switchport hybrid vlan 3001-3010 tag
switchport qinq customer
ZXR10(cong)#show run interface fei_1/2
description TO-DS02
no negotiation auto
switchport mode hybrid
switchport hybrid native vlan 4094
switchport hybrid vlan 99 tag
switchport hybrid vlan 100 untag
switchport hybrid vlan 3011-3020 tag
switchport qinq customer
ZXR10(cong)#show run interface fei_2/1
description to-T64G
no negotiation auto
hybrid-attribute ber
switchport mode hybrid
switchport hybrid native vlan 1
switchport hybrid vlan 99 tag
switchport hybrid vlan 101-150 tag
switchport hybrid vlan 3001-3500 tag
switchport hybrid vlan 501-2500 tag
switchport hybrid vlan 4094 untag
switchport qinq uplink
With the above information results,
engineers found that native VLAN on each
port was Helpervlan 4094. Double-tagged
services were implemented through VLAN
QinQ. Therefore, MAC learning was in
Helpervlan 4094, and the VLAN 100 would
not learn MAC addresses. That is, packets
in VLAN 100 were broadcasted to down-
stream devices.
After asking the ofce personnel about
services running, engineers knew that that
there were a lot of double-tagged PPPOE
services that were transparently transmit-
ted.
According to the plan, users were
identified by inner tags and areas were
identied by outer tags. Therefore, PPPoE
service on ZXR10 3952 was only allocated
with one outer tag vlan 100, and all ports
were in this vlan.
From above information, downstream
PPPOE trafcs were broadcasted in VLAN
100. Since the uplink port was 1000M and
the downstream traffics were great, but
customer port was 100M, downstream
broadcast traffics were congested. This
made internet surng slow.
Solution
Engineers set the outer tag VLAN id
to native VLAN id on customer port. The
problem was solved.
-
8/2/2019 Maintenance Experience Issue160(Data Products)
22/32
Maintenance Experience20
April 2009 Issue 160
Malfunction Situation
As shown in Figure 1, ACL was applied on interface Fei_1/1
of ZXR10 3928 switch to forbid PC to ping to 3928. The congu -
ration failed but still PC could ping 3928 successfully.
proved priority of ICMP packets through a set of
special rules. These rules were placed ahead of
ACL. ICMP was in protocol protection range. Proto-
col protected packet had a higher priority than ACL.
As the value of parameter on
ZXR10 3928 switch was 0 by default, the command
of disabling ICMP became invalid. As a result, PC
could still ping to ZXR10 3928 switch successfully.
Solution
Engineers modied the conguration of ZXR10
3928 switch, as shown below.
acl extend number 101
rule 1 deny icmp 10.40.184.0 0.0.3.255 any
rule 2 permit ip any any!
int fei_1/1
protpcol-protect mode icmp disable
switchport access vlan 1
ip access-group 101 1 in //Set the value of pa-
rameter prole-number to 1, that is, protocol-
protect is disabled
Experience Summary
For downlink interface where SVLAN is en-
abled, the value of parameter
must be 1. When protocol protection is enabled,
the value of parameter must be 0.
When a switch is used as L2 device, then value
of parameter is allowed to be 1.
However, in this situation, some control packets
will fail to be received on the interface and some
protocol calculations will be wrong. Therefore, set
the value of parameter to 0.
Operational Failure through ACL Zhang Fan / ZTE Corporation
Figure 1. Network Topology
Malfunction Analysis
Engineers checked configuration of ZXR10 3928 switch, as
shown below.
acl extend number 101
rule 1 deny icmp 10.40.184.0 0.0.3.255 any
rule 2 permit ip any any
!
int fei_1/1
protpcol-protect mode icmp disable
switchport access vlan 1ip access-group 101 0 in
The command to apply ACL is shown below:
ip access-group in
In this command, parameter is required. The
value is 0 or 1. 0 indicates that protocol protection is enabled and
1 indicates protocol protection is disabled. Protocol protection is
enabled by default on interface, that is, the default value of is 0.
After protocol protection function was enabled, switch im-
Key words: ACL, ping, protocol protection
-
8/2/2019 Maintenance Experience Issue160(Data Products)
23/32
Data Products
www.zte.com.cn
21
Network Topology
IBGP protocol runs between T1200-1 and
T1200-2. EBGP runs between T1200-1 and
T128-1. EBGP runs between T1200-2 and T128-2.
IBGP protocol runs between T128-1 and T128-2.
IBGP and OSPF run between 128 and T64.
The network topology is shown in Figure 1.
ip address 10.0.0.5 255.255.255.252
router bgp 4809
neighbor 3.3.3.3 remote-as 65514 //
Designated EBGP neighbor
neighbor 3.3.3.3 activate
neighbor 3.3.3.3 update-source loop-
back1
neighbor 3.3.3.3 ebgp-multihop
neighbor 10.0.0.2 remote-as 4809 //
Designated IBGP neighbor
neighbor 10.0.0.2 activate
Conguration of T1200-2:
interface loopback1
ip address 2.2.2.2 255.255.255.255
interface pos48_1/1
ip address 10.0.0.2 255.255.255.252
interface pos48_2/1
ip address 10.0.0.9 255.255.255.252
router bgp 4809neighbor 4.4.4.4 remote-as 65514 //
Designated EBGP neighbor
neighbor 4.4.4.4 activate
neighbor 4.4.4.4 update-source loop-
back1
neighbor 4.4.4.4 ebgp-multihop
neighbor 10.0.0.1 remote-as 4809 //
Designated IBGP neighbor
neighbor 10.0.0.1 activate
Figure 1. Network Topology
Malfunction SituationDevice congurations are shown below.
Conguration of T1200-1:
interface loopback1
ip address 1.1.1.1 255.255.255.255
interface pos48_1/1
ip address 10.0.0.1 255.255.255.252
interface pos48_2/1
Key words: EBGP, neighbor
Abnormal EBGP NeighborhoodEstablishmentAbnormal EBGP NeighborhoodEstablishmentXia Ying / ZTE Corporation
-
8/2/2019 Maintenance Experience Issue160(Data Products)
24/32
Maintenance Experience22
April 2009 Issue 160
Conguration of T128-1:
interface loopback1
ip address 3.3.3.3 255.255.255.255
interface pos48_1/1
ip address 10.0.0.6 255.255.255.252
interface gei_2/1
ip address 10.10.10.1 255.255.255.252
interface gei_3/1
ip address 10.10.10.5 255.255.255.252
router ospf 100 // Starting OSPF process
network 3.3.3.3 0.0.0.0 area 0.0.0.0
network 10.10.10.0 0.0.0.3 area 0.0.0.0
network 10.10.10.4 0.0.0.3 area 0.0.0.0
router bgp 65514
neighbor 1.1.1.1 remote-as 4809 // Des-
ignated EBGP neighbor
neighbor 1.1.1.1 activate
neighbor 1.1.1.1 update-source loopback1
neighbor 1.1.1.1 ebgp-multihop
neighbor 4.4.4.4 remote-as 65514 //
Designated IBGP neighbor
neighbor 4.4.4.4 activate
neighbor 4.4.4.4 update-source loopback1
neighbor 5.5.5.5 remote-as 65514
neighbor 5.5.5.5 activate
neighbor 5.5.5.5 update-source loopback1
Conguration of T128-2:
interface loopback1
ip address 4.4.4.4 255.255.255.255
interface pos48_1/1ip address 10.0.0.10 255.255.255.252
interface gei_2/1
ip address 10.10.10.2 255.255.255.252
interface gei_3/1
ip address 10.10.10.9 255.255.255.252
router ospf 100 //Starting OSPF Pro-
cess
network 4.4.4.4 0.0.0.0 area 0.0.0.0
network 10.10.10.0 0.0.0.3 area 0.0.0.0
network 10.10.10.8 0.0.0.3 area 0.0.0.0
router bgp 65514
neighbor 2.2.2.2 remote-as 4809 // Designated
EBGP neighbor
neighbor 2.2.2.2 activate
neighbor 2.2.2.2 update-source loopback1
neighbor 2.2.2.2 ebgp-multihop
neighbor 3.3.3.3 remote-as 65514 // Designated
IBGP neighbor
neighbor 3.3.3.3 activate
neighbor 3.3.3.3 update-source loopback1
neighbor 6.6.6.6 remote-as 65514
neighbor 6.6.6.6 activate
neighbor 6.6.6.6 update-source loopback1
Conguration of T64E-1:
interface loopback1
ip address 5.5.5.5 255.255.255.255
interface gei_1/1
ip address 10.10.10.6 255.255.255.252
router ospf 100 //Starting OSPF Process
network 5.5.5.5 0.0.0.0 area 0.0.0.0
network 10.10.10.4 0.0.0.3 area 0.0.0.0
router bgp 65514
neighbor 3.3.3.3 remote-as 65514 // Designated
IBGP neighbor
neighbor 3.3.3.3 activate
neighbor 3.3.3.3 update-source loopback1
EBGP connection can not be established be-
tween T128-1 and T1200-1.
Malfunction Analysis
To nd out the problem, engineers took the fol-
lowing steps.
1. Engineers viewed BGP neighbor informa-
tion on T128-1, as shown below.
-
8/2/2019 Maintenance Experience Issue160(Data Products)
25/32
Data Products
www.zte.com.cn
23
T128-1#show ip bgp summary
Neighbor Ver As MsgRcvd MsgSend Up/Down(s) State
1.1.1.1 4 4809 0 0 0h Connect
4.4.4.4 4 65514 255152 255339 13w1d2h Estab-
lished
5.5.5.5 4 65514 27912 273892 1w1d20h Established
2. Engineers pinged to the neighbor with
which the connection was established normally on
T128-1, as shown below.
T128-1#ping 4.4.4.4
sending 5,100-byte ICMP echos to 4.4.4.4,timeout is
2 seconds.
!!!!!
Success rate is 100 percent(5/5),round-trip
min/avg/max=0/8/20ms
3. Engineers pinged to the neighbor with
which the connection was established abnormally
on T128-1, as shown below.
T128-1#ping 1.1.1.1
sending 5,100-byte ICMP echos to 1.1.1.1,timeout is
2 seconds.
.....
Success rate is 0 percent(0/5)
4. Engineers viewed network segment route
on T128-1, as shown below.
show ip route 1.1.1.1
IPv4 Routing Table:
Dest Mask Gw Interface Owner pri metric
BGP route protocol sent protocol packets based
on TCP protocol 179. It could be determined that
the links were established unsuccessfully, because
IP router was not reachable. It was necessary to
add static routes between T128 and T1200.
Solution
Engineers added static routes on
T1200-1 and T128-1.The static route conguration added to
T1200-1 is shown below.
T1200_1(config)#ip route 3.3.3.3
255.255.255.255 10.0.0.6
The static route conguration added to
T128-1 is shown below.
T128_1(config)#ip route 1.1.1.1255.255.255.255 10.0.0.5
Engineers viewed neighbor information
on T128-1, as shown below.
In the same way, engineers added
static routes on T128-2 and T1200-2.
Therefore, the neighbor relationship can
be established normally.
Experience Summary
To configure EBGP interconnection
and establish neighborhood by loopback
address, the static route conguration can
not be neglected.
Additionally, the command neighbor
ebgp-multihop is necessary
to establish EBGP with loopback address-
es.
T128-1#show ip bgp summary
Neighbor Ver As MsgRcvd MsgSend Up/Down(s) State
1.1.1.1 4 4809 2230 2221 1h Established
4.4.4.4 4 65514 264329 265436 13w1d3h Established
5.5.5.5 4 65514 299126 283898 1w1d21h Established
-
8/2/2019 Maintenance Experience Issue160(Data Products)
26/32
-
8/2/2019 Maintenance Experience Issue160(Data Products)
27/32
Data Products
www.zte.com.cn
25
CPU 5s of master MP is 23%, which was in normal range
(in case CPU 5s exceeds 40%, it indicates there is some-
thing wrong. 30% is normal when there are large service
trafcs).
By analyzing CPU, the previous judgments were wrong.
It was necessary to nd out the problem from other aspects.
2. It may be the problem of T160G-1 itself, for example,
CPU of the main board was high or corresponding line inter-
face card CPU was high, which led to that message queue
was completely occupied by other packets transmitted to
CPU and therefore telnet packets were dropped.
Engineers executed command show processor on
T160G-1 to view CPU utilizations of the main board and line
interface cards, as shown below.
telned to T64G through T160G-2. The response speed
was normal. Engineers checked CPU of line interface
card 1 on T160G-2, it was normal. It could be assumed
that the fault was related to high CPU utilization of line
interface card 1 on T160G-1.
3. The reason for line interface card 1 CPU be-
ing high was that there were large numbers of packets
being up-sent to line interface card CPU. They may be
protocol packets or ordinary packets. When engineers
executed command show logging alarm, it was found
that there was no alarm for receiving a large number
of protocol packets. Therefore, the packets may not be
protocol packets. It was assumed that it was service
packets that ooded CPU.
Engineers executed command capture npc 1 read-
speed 20 on T160G-1 to capture packets to line card 1.
The result was shown below.
T160G-1#show processor
M: Master processor
S: Slave processor
Peak CPU: CPU peak utility measured in 2 minutes
PhyMem: Physical memory (megabyte)
Panel CPU(5s) CPU(30s) CPU(2m) Peak CPU PhyMem Memory
MP(M)1 37% 35% 36% 43% 512 38.164%
MP(S)2 8% 8% 8% 12% 512 19.578%
NP(M)1 37% 37% 38% 39% 256 36.105%
NP(M)2 13% 12% 13% 17% 256 36.105%
NP(M)3 15% 15% 16% 19% 128 54.055%
NP(M)4 14% 15% 15% 15% 128 54.055%
NP(M)5 14% 15% 15% 19% 128 54.055%
NP(M)6 23% 23% 23% 27% 128 54.056%
NP(M)7 14% 13% 13% 14% 128 50.971%
CPU of master main board was fairly high and CPU uti-
lization of line interface card 1 was particularly higher thanthose of other line interface cards.
All edge nodes T64G were connected to line interface
card 1 of T160G-1, except for T160G-2 (connected to line in-
terface cards 3 and 4). If CPU utilization of line interface card
1 was too high, the peed of accessing all T64G switches (ex-
cept for T160G-2) would be slow.
Engineers validated this assumption, it was correct. To
perform further validation, engineers connected all edge
nodes T64G to line interface card 1 of T160G-2, and then
T160G-1(cong)#capture npc 1 readspeed 20
IP Packet on NPC: 1
DST_IP SRC_IP ovid ivid TTL PRO DIR Port
10.0.9.123 10.107.25.122 9 NULL 61 6 RX 4
233.18.204.166 124.108.15.105 100 NULL 7 17 RX 1210.0.9.123 10.113.35.122 9 NULL 61 6 RX 2
10.0.9.123 10.137.26.69 9 NULL 61 6 RX 1
10.0.9.123 10.133.0.122 9 NULL 61 6 RX 1
10.0.9.123 10.119.45.123 9 NULL 61 6 RX 2
233.20.204.4 124.108.15.100 100 NULL 7 17 RX 12
233.20.204.4 124.108.15.100 100 NULL 7 17 RX 12
10.0.9.123 10.146.22.61 9 NULL 61 6 RX 6
10.0.9.123 10.124.122.77 9 NULL 61 6 RX 5
233.20.204.4 124.108.15.100 100 NULL 7 17 RX 12
233.20.204.4 124.108.15.100 100 NULL 7 17 RX 12IP Packet on NPC: 1
PDST_IP SRC_IP ovid ivid TTL PRO DIR Port
10.0.9.123 10.115.5.123 9 NULL 61 6 RX 2
233.20.204.17 124.108.15.100 100 NULL 7 17 RX 12
IP Packet on NPC: 1
DST_IP SRC_IP ovid ivid TTL PRO DIR Port
10.0.9.123 10.129.140.120 9 NULL 61 6 RX 1
10.0.9.123 10.113.36.110 9 NULL 61 6 RX 2
-
8/2/2019 Maintenance Experience Issue160(Data Products)
28/32
Maintenance Experience26
April 2009 Issue 160
is made clear, it can be known that which line card
corresponds to which slot uniquely.
In usual cases, there could not be many multicast ser-
vice packets up-sent to line interface card CPU. Therefore, it
was assumed that there was something wrong with multicast
routing table.
4. According to the above analysis result, engineers
executed command show ip mroute to view multicast routing
table. Group 233.18.204.166 was one of the multicast group
addresses of CPU captured packets. Take it for example
here for analysis.
T 1 6 0 G - 1 ( c o n f i g ) # s h o w i p m r o u t e g r o u p
223.18.204.166
IP Multicast Routing Table
Flags:D-Dense,S-Sparse,C-Connected,L-Local,P-Pruned,
R-RP-bit set,F-Register ag,T-SPT-bit set,J-Join SPT,
M-MSDP created entry,N-No Used,U-Up Send,
A-Advertised via MSDP,X-Proxy Join Timer Running,
*-Assert ag
Statistic:Receive packet count/Send packet count
Timers:Uptime/Expires
Interface state:Interface,Next-Hop or VCD,State/Mode
(*,233.18.204.166),1d1h/00:03:34,RP 124.108.8.3,
150295/150295,ags:SC
Incoming interface: vlan100, RPF nbr 10.0.100.1
Outgoing interface list:
vlan40, Forward/Sparse, 1d1h/00:03:29 C
By execut ing command show ip mroute group
233.18.204.166 repeatedly, It was found that only (*, g)
entry was in this multicast table, and there was no (s,
g) entry. Packet sending/receiving count of (*,g) entry
(150295/150295) increased continuously. Multicast data ow
were forwarded according to (*, g) entry and packets for-
warded according to (*, g) entry were be up-sent to CPU for
processing, which led to high CPU.
Note: Packets forwarded according to (s,g) entry are pro-
cessed by hardware directly.
5. Engineers continued to analyze the reason why en-
try (s, g) was unavailable in multicast routing table.
10.0.9.123 10.119.97.39 9 NULL 61 6 RX 2
233.20.204.32 124.108.15.102 100 NULL 7 17 RX 12
233.20.204.32 124.108.15.102 100 NULL 7 17 RX 12233.20.204.32 124.108.15.102 100 NULL 7 17 RX 12
233.20.204.32 124.108.15.102 100 NULL 7 17 RX 12
233.20.204.32 124.108.15.102 100 NULL 7 17 RX 12
10.0.9.123 10.115.66.108 9 NULL 61 6 RX 2
233.20.204.4 124.108.15.100 100 NULL 7 17 RX 12
10.0.9.123 10.127.3.12 9 NULL 61 6 RX 4
233.20.204.4 124.108.15.100 100 NULL 7 17 RX 12
Engineers analyzed the result of packet capture (take
one packet for example), as shown below.
IP Packet on NPC: 1
DST_IP SRC_IP ovid ivid TTL PRO DIR Port
233.20.204.17 124.108.15.100 100 NULL 7 17 RX 12
The following parameters were concerned.
DST_IP, SRC_IP: Destination IP and source IP
of a packet; all packets captured by command
capture must be up-sent to line card CPU.
Large number of multicast service packets (withdestination address beginning with 233) and a
few unicast packets (with destination address to
be 10.0.9.123) are found in CPU packet capture
on slot 1.
Ovid: Outer VLAN tag of the packet. It can be
seen that it is xed that all multicast packets are
up-sent to CPU through vlan100 and all unicast
packets are sent to CPU through vlan9.
TTL: TTL value of the packet. It is normal as long
as the value is not 1.
DIR: Direction of the packet, in receiving direction
or sending direction. For receiving direction, it
is RX, indicating the packet is up-sent to CPU
and for sending direction, it is TX, indicating the
packet is sent out from CPU
Port: The physical interface to receive (send)
a packet. As slot number has been specified
in command, so as long the physical interface
-
8/2/2019 Maintenance Experience Issue160(Data Products)
29/32
Data Products
www.zte.com.cn
27
In normal cases, entry (s,g) could generate as
long as multicast data ow was available and DR
knew IP address of multicast source and RPT was
switched to SPT. If (s,g) entry faied to be gener-
ated, users could execute command show ip rpf to
view whether RPF check is passed.
When an interface on the switch receives multi-
cast packet sent from a multicast source. if the path
from switch to this multicast source actually passes
through this interface according to the routing table
of this switch, RPF check is passed.
Engineers continued to analyze the result of
CPU packet capture, as shown below.
T160G-1#show ip rpf 124.108.15.105
RPF information:
RPF interface vlan501
RPF neighbor 61.154.120.201 (isnt neighbor)
RPF metric preference 1 RPF metric value 0
RPF type : unicast
Engineers analyzed the result of reverse path
check. Outgoing interface to multicast source
124.108.15.105 was 61.154.120.201 (line inter-
face card 7, vlan 501, default route); with CPU
packet capture it was found that packets whose
multicast group address was 233.18.204.166 were
forwarded from interface 12 of line interface card 1.
Therefore, RPF check is not passed and entry (s,g)
could not be generated.
6. With the above analysis, there were two
ways to decrease CPU utilization of line interface
card.i. Configure ACL to filter these multicast
packets.
ii. Congure a static route to enable the route
to 124.108.15.105 pass through interface 12 of line
card 1 and thus RPF check is passed.
Since the group 233.18.204.166 was used for
forwarding multicast service, static route was con-
gured here so that RPF check could pass.
Conguration of static route was shown below.
ip route 124.108.15.0 255.255.255.0
10.0.100.1
After static route was congured, engi-
neers performed RPF check. The informa-
tion was shown below.
T160G-1#show ip rpf 124.108.15.105
RPF information:
RPF interface vlan100 pimsm
RPF neighbor 10.0.100.1 (is neighbor)
RPF metric preference 1
RPF metric value 0
RPF type : unicast
According to the RPF check, it was
found that the interface belonged to
vlan100, where there was only one inter-
face gei_1/12 and it was neighbor. RPF
check was passed.
By execut ing command show ip
mroute, it was found that (s,g) entry was
generated and data ow could be forward-
ed according to (s, g) entry rather than ac-
cording to (*.g).
T160G-1#show ip mroute group
233.18.204.166
IP Multicast Routing Table
F l a g s : D - D e n s e , S - S p a r s e , C -
Connected,L-Local,P-Pruned,
R-RP-bit set,F-Register flag,T-SPT-bit
set,J-Join SPT,
M-MSDP created entry,N-No Used,U-
Up Send,
A-Advertised via MSDP,X-Proxy Join
Timer Running,
*-Assert ag
Statistic:Receive packet count/Send
packet count
Timers:Uptime/Expires
Interface state:Interface,Next-Hop or
VCD,State/Mode
-
8/2/2019 Maintenance Experience Issue160(Data Products)
30/32
Maintenance Experience28
April 2009 Issue 160
(*, 233.18.204.166), 1d2h/00:02:48,
RP 124.108.8.3,
150385/150385, ags: SCIncoming interface: vlan100, RPF nbr
10.0.100.1
Outgoing interface list:
v l a n 4 0 , F o r w a r d / S p a r s e ,
1d2h/00:02:43 C
(124.108.15.105, 233.18.204.166),
00:44:39/00:02:48 , 6340/6340 ,
ags: CJT
Incoming interface: vlan100, RPF nbr
10.0.100.1
Outgoing interface list:
v l a n 4 0 , F o r w a r d / S p a r s e ,
00:44:39/00:02:43 C
By executing command show ip mroute
group repeatedly to compare packet send-
ing/receiving counts, it was verified that
data ow were forwarded according to (s,g)
entry rather than according to (*.g). Engineers ex-
ecuted command show processor to view CPU uti-
lization of line interface card and it was found that it
increased rather than decreases. It was normal for
T160G-1 to telnet the other T64Gs connected to it.
Experience Summary
In normal cases, as for each group, there were
two entries available in multicast routing table, (s,g)
and (*,g). Both are indispensable. If either of the
two entries does not exist or it is abnormal, it is
necessary to analyze the reason.
Packets forwarded according to (s,g) areprocessed by hardware and packets forwarded
according to (*,g) are processed by software. In
normal cases, when device receives multicast data
ow for the rst time, the device forwards it accord-
ing to (*,g) and it will implement SPT changeover
immediately to generate (s,g) entry, and then for-
ward the multicast data ow by hardware.
-
8/2/2019 Maintenance Experience Issue160(Data Products)
31/32
-
8/2/2019 Maintenance Experience Issue160(Data Products)
32/32