main contactors for electrical devices k3-..nb.. · main contactors for electrical devices...

2
Benedict GmbH Tel.: +43 (1) 251 51-0 e-mail: [email protected] Lieblgasse 7, A-1220 Vienna Fax: +43 (1) 251 51-89 www.benedict.at D1029E Technical data are subject to change without notice. Main Contactors for electrical devices K3-..NB.. Specifically developed for IEC 60335 applications Switch AC1 loads up to 52A Space saving design, large box terminals International approbations AC- or DC- operated New Technical data according to IEC 947-4-1, EN 60947-4-1, VDE 0660 Main contacts Type K3-10NB K3-18NB Rated insulation voltage U i V~ 690 690 Making capacity I eff bei U e = 690V~ A 200 200 Breaking capacity I eff 400V~ A 180 200 Utilization category AC1 Switching of resisitve load Rated operational current I e (=I th ) 690V A 45 52 at 40°C, open Rated operational power of three phase resistive loads 230V kW 17,9 20,7 50-60Hz, cosϕ= 1 400V kW 31,1 36 440V kW 34,2 39,6 500V kW 38,9 45 690V kW 53,7 62,1 Rated operational current I e (=I th ) 690V A 35 40 at 60°C, enclosed Rated operational power of three phase resistive loads 230V kW 13,9 15,9 50-60Hz, cosϕ= 1 400V kW 24,2 27,7 440V kW 26,6 30,4 500V kW 30,3 34,6 690V kW 41,8 47,8 Rated operational current I e (=I th ) 690V A 32 37 at 75°C, open Rated operational current I e (=I th ) 690V A 27 32 at 90°C, open Minimum cross-section of conductor at load with I e (=I th ) mm² 10 16 Cable cross-sections 1 cable per clamp main connector solid or stranded 2,5 - 16mm² flexible 2,5 -10mm² flexible with multicore cable end 2,5 - 10mm² 2 cables per clamp solid or stranded 16+(1,5-2,5)mm² 10+ (1,5-6)mm² 6+(1,5-10)mm² 4+(1,5-10)mm² flexible 16+(1,5-2,5)mm² 10+ (1,5-4)mm² 6+(1,5-6)mm² large box terminals × × 2,5 - 16mm²

Upload: others

Post on 12-Oct-2019

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Main Contactors for electrical devices K3-..NB.. · Main Contactors for electrical devices K3-..NB.. Specifically developed for IEC 60335 applications Switch AC1 loads up to 52A Space

Benedict GmbH Tel.: +43 (1) 251 51-0 e-mail: [email protected] 7, A-1220 Vienna Fax: +43 (1) 251 51-89 www.benedict.at

D10

29E

Tec

hnic

al d

ata

are

subj

ect t

o ch

ange

with

out n

otic

e.

Main Contactors for electrical devices K3-..NB..

Specifically developed for IEC 60335 applications

Switch AC1 loads up to 52A

Space saving design, large box terminals

International approbations

AC- or DC- operated

New

Technical data according to IEC 947-4-1, EN 60947-4-1, VDE 0660

Main contacts Type K3-10NB K3-18NB

Rated insulation voltage Ui V~ 690 690

Making capacity Ieff bei Ue = 690V~ A 200 200 Breaking capacity Ieff 400V~ A 180 200

Utilization category AC1 Switching of resisitve load Rated operational current Ie (=Ith) 690V A 45 52 at 40°C, open Rated operational power of three phase resistive loads 230V kW 17,9 20,7 50-60Hz, cosϕ= 1 400V kW 31,1 36 440V kW 34,2 39,6 500V kW 38,9 45 690V kW 53,7 62,1

Rated operational current Ie (=Ith) 690V A 35 40 at 60°C, enclosed Rated operational power of three phase resistive loads 230V kW 13,9 15,9 50-60Hz, cosϕ= 1 400V kW 24,2 27,7 440V kW 26,6 30,4 500V kW 30,3 34,6 690V kW 41,8 47,8

Rated operational current Ie (=Ith) 690V A 32 37 at 75°C, open

Rated operational current Ie (=Ith) 690V A 27 32 at 90°C, open

Minimum cross-section of conductor at load with Ie (=Ith) mm² 10 16

Cable cross-sections 1 cable per clamp main connector solid or stranded 2,5 - 16mm² flexible 2,5 -10mm² flexible with multicore cable end 2,5 - 10mm² 2 cables per clamp solid or stranded 16+(1,5-2,5)mm² 10+ (1,5-6)mm² 6+(1,5-10)mm² 4+(1,5-10)mm² flexible 16+(1,5-2,5)mm² 10+ (1,5-4)mm² 6+(1,5-6)mm²

large box terminals

×× 2,5 - 16mm²

Page 2: Main Contactors for electrical devices K3-..NB.. · Main Contactors for electrical devices K3-..NB.. Specifically developed for IEC 60335 applications Switch AC1 loads up to 52A Space

w w w . b e n e d i c t . a t

K3-10NB.., K3-18NB..

Dimensions for K3-..NB Main contactors:

AC operated DC operated

K3-10NB.. K3-10NB..= K3-18NB.. K3-18NB..=