magnetic oil level gauge (mog) - 3.imimg.com3.imimg.com/data3/iq/rd/my-8121410/pioneer... ·...

2
1 4 7 3 5 6 2 MAGNETIC OIL LEVEL GAUGE (MOG) The PIONEER Gas & Oil Relay is a nearly ideals protective device for protection of oil immersed Transformers. This is available in three models. The PIONEER Relay is particularly sensitive and simple indicator of internal faults in Oil immersed Transformers. The quick operation of alarm contact warns you once the fault is initiated and in event of continuing fault, tripping contact effectively limits the damage and reduces the cost or repairs by isolating transformer from circuit. The PIONEER Relay comprise of hinges Bucket and reed switch assemble for both alarm and trip circuits. Entire assembly is in a tight case which has two glass windows. MOUNTING : FOR PROTECTION OF OIL IMMERSED TRANSFORMERS BUCHHOLZ RELAY AND OIL SURGE RELAY (OSR) FACTORY ADDRESS: PIONEER ELECTRICALS CORPORATION AUTHORISED DEALER web : www.pioneertr.in, www.transformerspares.com Buchholz Relay Oil Surge Relay (OSR) Pressure Release Devise (PRD) Magnetic Oil Level Gauge (MOG) 1 2 3 4 , , , , Silica Gel Breather Radiator Valves Prismatic Oil Level Gauge 5 6 7 , , BRANCH: AHMEDABAD : +91-97251 41557 UDAIPUR : +91-97845 63632 Manufacturer of Transformer Spares Highest in Class of Safety Robust Design Alarm circuit operators in case of minor faults e.g. faults in core lamination, local overheating in winding, bad connections, low Oil level etc. In case of major faults like short circuit between turns phase and insulation breakdown etc, the trip switch will operate. The PIONEER Relays are tested for routine tests laid down in I.S.3637 and periodically type tested to re- validate design & manufacturing practices. A detailed write up is available on request. This gauge measures the contents of liquid inside a static tank and continuously indicates the contents on its calibrated scale. It has numerous application but in transformer industry for visual indication of oil contents inside the conservator vessel, this gauge is most popular. Even electrical contacts are also provided to establish indication on remote mode of abnormal position. GENERAL : To mount the indicator, customer is required to provide a suitable pad. The indicator is mounted vertically or at inclination to facilitate easy viewing. Normally indicator is mounted at the center of the flat end-cover of conservator. This Depends weather conservator with air cell or without and accordingly position may vary. PLOT NO 89, NARAYAN COMPLEX, GIDC,NEAR VADSAR BRIDGE MAKARPURA, VADODARA, GUJARAT, INDIA - 390010. Cell No : +91-98980 96987, 99785 55557, 98257 21557 e-mail id : , [email protected] [email protected] web : www.pioneertr.in, www.transformerspares.com 1 6 4 5 3

Upload: others

Post on 29-Jun-2020

9 views

Category:

Documents


1 download

TRANSCRIPT

1

4

7

3

56

2

MAGNETIC OIL LEVEL GAUGE (MOG)

The PIONEER Gas & Oil Relay is a nearly ideals protective

device for protection of oil immersed Transformers. This is

available in three models.

The PIONEER Relay is particularly sensitive and simple

indicator of internal faults in Oil immersed Transformers. The

quick operation of alarm contact warns you once the fault is

initiated and in event of continuing fault, tripping contact

effectively limits the damage and reduces the cost or repairs by

isolating transformer from circuit.

The PIONEER Relay comprise of hinges Bucket and reed switch

assemble for both alarm and trip circuits. Entire assembly is in

a tight case which has two glass windows.

MOUNTING :

FOR PROTECTION OF OIL IMMERSED TRANSFORMERS

BUCHHOLZ RELAY AND OIL SURGE RELAY (OSR)

FACTORY ADDRESS:

PIONEER ELECTRICALS CORPORATION AUTHORISED DEALER

web : www.pioneertr.in, www.transformerspares.com

Buchholz Relay Oil Surge Relay (OSR) Pressure Release Devise (PRD) Magnetic Oil Level Gauge (MOG)1 2 3 4

, , , ,

Silica Gel Breather Radiator Valves Prismatic Oil Level Gauge5 6 7

, ,

BRANCH:

AHMEDABAD : +91-97251 41557 UDAIPUR : +91-97845 63632

Manufacturer of Transformer Spares“ ”Highest in Class of Safety Robust Design

Alarm circuit operators in case of minor faults e.g. faults in core lamination, local overheating in

winding, bad connections, low Oil level etc. In case of major faults like short circuit between turns phase

and insulation breakdown etc, the trip switch will operate.

The PIONEER Relays are tested for routine tests laid down in I.S.3637 and periodically type tested to re-

validate design & manufacturing practices.

A detailed write up is available on request.

This gauge measures the contents of liquid inside a

static tank and continuously indicates the contents on

its calibrated scale. It has numerous application but in

transformer industry for visual indication of oil contents

inside the conservator vessel, this gauge is most

popular. Even electrical contacts are also provided to

establish indication on remote mode of abnormal

position.

GENERAL :

To mount the indicator, customer is required to provide

a suitable pad. The indicator is mounted vertically or at

inclination to facilitate easy viewing. Normally indicator

is mounted at the center of the flat end-cover of

conservator. This Depends weather conservator with

air cell or without and accordingly position may vary.

PLOT NO 89, NARAYAN COMPLEX, GIDC,NEAR VADSAR BRIDGE

MAKARPURA, VADODARA, GUJARAT, INDIA - 390010.

Cell No : +91-98980 96987, 99785 55557, 98257 21557

e-mail id : ,[email protected] [email protected]

web : www.pioneertr.in, www.transformerspares.com

1 64 53

PIONEER ELECTRICALS CORPORATION IS IN THE FIELD OF MANUFACTURING OF MAJOR RANGE OF

TRANSFORMER ACCESSORIES. WE ARE PARTNERS MANAGED UNIT AND HAVING FULLY EQUIPPED

WORKSHOP TO MEET STRINGENT QUALITY STANDARDS TO CATER NEED OF OEMS / END USERS.

WE ARE COMMITTED TO OFFER BEST QUALITY PRODUCTS AND IT IS ENSURED BY TEAM OF

EMPLOYEES HAVING LONG STANDING RICH EXPERIENCE & EXPERTISE IN THE FIELD.

COMPANY WAS INCORPORATED BY HIGHLY TECHNICAL PERSON AND NOW RUN BY TECHNOCRATS

TO CONSOLIDATE ITS POSITION IN TRANSFORMER ACCESSORIES INDUSTRY. WE HAVE

CAPABILITIES TO DEVELOP NATION STANDARD PRODUCTS AND ALSO TO DEVELOP

INTERNATIONAL STANDARD PRODUCTS IN OUR MANUFACTURING UNIT LOCATED AT

MAKARPURA, VADODARA, GUJARAT, INDIA.

WE HAVE ABILITY AND INCLINATION TO DEVELOP TAILOR MADE PRODUCT FOR SPECIFIC NEEDS

THROUGH OUR RESEARCH AND DEVELOPMENT.

OUR THRUST REMAINS ON UN COMPROMISED PRODUCT QUALITY FOR FUTURE GROWTH &

EXPANSION BY KEEPING SATISFACTION OF CUSTOMERS.

PIONEER ELECTRICALS CORPORATION WAS ESTABLISHED IN YEAR OF 2001 AND NOW TAKEN OVER BY

TRANSFORMER EXPERT IN 2013. OWNERS HAVE LONG STANDING EXPERIENCE IN UNDERSTANDING

THE TRANSFORMER STARTING FROM FREEZING SPECIFICATIONS, MANUFACTURING, TESTING,

MAINTENANCEANDREHABILITATION/REPAIRS/REFURBISHMENTETC.

COMPANY PROFILE OUR PRODUCTS

1.APPLICATION :

To Order, Or For Quotation, Specify:

1. Model Number

- T3 - With Switch

- T6 - With Switch (1 NO + 1 NC)

- T6-2 - With Switch (2 NO + 2 NC)

- T6W - Without Switch

2. Operating Pressure

a) 0.42 Kg/cm (6PSI)

b) 0.49 Kg/cm (7PSI)

c) 0.56 Kg/cm (8PSI)

d) 0.70 Kg/cm (10PSI)

2

2

2

2

e) Other than above

PRESSURE RELIEF VALVE (PRV/PRD)SILICA

GEL

BREATHER

RADIATOR VALVE

The Radiator Valve is used on all oil cooled transformer to

control the flow of oil from transformer to radiator. The

valve is equipped with a butterfly flap moving on a pivot

which can be turned on to open. The valve remain in

open position when the transformer is on in operation.

In case of leakage from any of the radiator tubes/fins the

butterfly flap is closed and the tube of the radiator can be

replaced/repair.

The Pressure Relief Valve (PRV) is designed as a safety device be used on

Power Transformer and similar oil electrical equipments. When pressure in

tank rises beyond predetermined safe limit the PRV operates & performs

following function.

1.1 Reduces the pressure in the tank by instantaneously opening the port of

all models.

1.2 Operates switch / switches which can be used to initiate precautionary

electrical system.

OUR PRODUCTS ARE ALREADY ON THE APPROVED LIST OF VARIOUS UTILITIES, TRANSFORMER OEMS,

CORPORATE HOUSES. WE ALSO ENJOY REPEAT SUPPLY ORDERS FROM OUR SATISFIED CUSTOMER.

HIGH QUALITY STANDARD, SIGNIFICANCE TAKEN CARE DESIGN AND LONG LASTING DURABLE

CONSTRUCTION PROVE VALUE FOR MONEY FOR OUR PRODUCT FOR TROUBLE FREE OPERATIONS FOR

YEARS TOGETHER.

WE ARE WELL KNOWN FOR TIMELY SERVICE, COMPETITIVE RATES AND OFFERING CUSTOMIZED

PRODUCTS.

EACH & EVERY PRODUCT UNDERGOES STRINGENT IN-HOUSE TESTING. TO RE VALIDATE THE DESIGN &

QUALITY, PRODUCTS ARE ALSO PERIODICALLY TESTED FOR TYPE TESTS AT ERDA-VADODARA.

OUR GROUP COMPANY ALSO OFFERS SALES & SERVICE FOR TRANSFORMER AS WELL SWITCH GEARS.

1. BUCHHOLZ RELAY

2. OIL SURGE RELAY

3.

4.

5.

6.

7. OIL FLOW INDICATORS

8. PRISMATIC OIL LEVEL GAUGES.

PRESSURE RELEASE VALVE / DEVICE (PRV/PRD)

MAGNETIC OIL LEVEL GAUGE (MOG)

SILICA GEL BREATHERS

TRANSFORMER RADIATOR VALVES

AS OF NOW COMPANY INVOLVED IN MANUFACTURING OF TRANSFORMER ACCESSORIES

SUCH AS,

web : www.pioneertr.in, www.transformerspares.com web : www.pioneertr.in, www.transformerspares.com