magnetic filters - boilermag...magnetic filters for heating systems of medium-large dimensions. •...

3
1. BOILERMAG 2. BOILERMAG XL 1" 1/2 3. BOILERMAG XT 2"-3"-4"-6"-8" C hoosing a magnetic sludge remover filter to be used inside domestic heating systems, guaran- tees the use of a simple device that needs no professional personnel for maintenance. The practical BoilerMag filters, thanks to their powerful magnets, hold impurities and both ferrous and non-ferrous debris present inside the closed circuit. Boiler Mag 1” exclusive pump adaptor for heating systems power flushing available on the optional. ADVANTAGES DIRECT CONTACT LIQUID/MAGNETE HIGHER MAGNETIC POWER ATTRACTION HIGHER FLOW RATE ON THE MARKET ADAPTOR FOR THE CLEANING WITH RESTORING PUMP MAGNETIC FILTERS - BoilerMag OPTIONAL At pag. 50 a. BoilerMag Pump Adaptor 1" a. 1. 2. 3. 48 - TLC - TECHNOLISTCATALOGUE | 20 16 - Boiler Performance ® EQUIPMENT At pag. 60 a. Power Flushing Pumps a.

Upload: others

Post on 02-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MAGNETIC FILTERS - BoilerMag...Magnetic filters for heating systems of medium-large dimensions. • Full stainless steel housing • Assemby at 360 • Neodymium magnet • Guarantees

1. BOILERMAG

2. BOILERMAG XL 1" 1/2

3. BOILERMAG XT 2"-3"-4"-6"-8"

Choosing a magnetic sludge remover filter to be used inside domestic heating systems, guaran-tees the use of a simple device that needs no professional personnel for maintenance.

The practical BoilerMag filters, thanks to their powerful magnets, hold impurities and both ferrous and non-ferrous debris present inside the closed circuit. Boiler Mag 1” exclusive pump adaptor for heating systems power flushing available on the optional.

A DVA N TAG E S

• DIRECT CONTACT LIQUID/MAGNETE• HIGHER MAGNETIC POWER ATTRACTION• HIGHER FLOW RATE ON THE MARKET• ADAPTOR FOR THE CLEANING WITH RESTORING PUMP

M AG N E T I C F I LT E R S - B o i l e r M a g

O P T I O N A L A t p a g . 5 0

a. BoilerMag Pump Adaptor 1"

a.

1. 2. 3.

48 - t l c - t e c h n o l i s tc ata l o g u e | 2 0 1 6 - B o i l e r Pe r f o r m a n c e ®

E Q U I P M E N T A t p a g . 6 0

a. Power Flushing Pumps

a.

Page 2: MAGNETIC FILTERS - BoilerMag...Magnetic filters for heating systems of medium-large dimensions. • Full stainless steel housing • Assemby at 360 • Neodymium magnet • Guarantees

wa

te

r so

ft

en

er

s w

ith

ou

t p

ow

er su

pp

ly

filt

er

s an

d c

ar

tr

idg

es

do

sing sy

ste

ms

an

d re

fills

do

sing

pu

mp

sd

esc

alin

g pu

mp

sa

na

lysis

too

lsc

on

dit

ion

ing

sola

r t

he

rm

al

ge

ot

he

rm

al

co

olin

gc

on

de

nsa

tio

nb

oile

rm

ag

ma

gn

et

iic f

ilte

rs

B O I L E R M AGMagneticsludgeremoverfilter,usefultoremovebothmagneticandnonmagneticdebrisfromthedomesticheatingsystem.Itextendsyourboilerandcirculatorlife.

• PatentedDUALFLOWtechnology• Assembyat360°• Neodymiummagnet• Usedasadditivescharge

C O D. 3 0 0 9 0 1 0 0 1 PAC K . 1 P C

CONNECTIONS 1"FPRESSURE 3barFLOW RATE 3,6m3/hTEMPERATURE 80°CMAGNET VOLUME 60cm3

INTERNAL VOLUME 500cm3

IRON HOLD 400gNON FERR. SYSTEM EFF. 90,7%DIMENSIONS H:240mmP:150mmø: 89 mm

- Other filters for heating systems of medium-large dimensions available on demand.

B O I L E R M AG X L Magneticfilterforheatingsystemsofmedium-largedimensions.

1 " 1 / 2 - C O D. 3 0 0 9 0 1 0 0 2 PAC K . 1 P C

CONNECTIONS 1"1/2FILTRATION 1000µmPN max6barTEMPERATURE 5-150°CFLOW RATE 8,5m3/hDIMENSIONS H: 291 mm L: 155 mm ø:102mm

• Reinforcedpolyammide• Neodymiummagnet• Usedasadditivescharge

2 " F L A N G E D - C O D. 3 0 0 9 0 1 0 0 3 PAC K . 1 P C

3 " F L A N G E D - C O D. 3 0 0 9 0 1 0 0 4 PAC K . 1 P C

4 " F L A N G E D - C O D. 3 0 0 9 0 1 0 0 5 PAC K . 1 P C

6 " F L A N G E D - C O D. 3 0 0 9 0 1 0 0 6 PAC K . 1 P C

8 " F L A N G E D - C O D. 3 0 0 9 0 1 0 0 7 PAC K . 1 P C

XT 2" XT 3" XT 4" XT6" XT 8"

CONNECTIONS 2" 3" 4" 6" 8"FILTRATION 1000µm 1000µm 1000µm 1000µm 1000µmPN max12bar max12bar max12bar max12bar max12barTEMPERATURE 5-150°C 5-150°C 5-150°C 5-150°C 5-150°CFLOW RATE 20m3/h 55 m3/h 85 m3/h 110m3/h 140m3/hDIMENSIONS H: 225 mm

L:260mmø:170mm

H:280mmL:360mmø:220mm

H:280mmL:360mmø:220mm

H:365mmL:470mmø: 325 mm

H:365mmL: 525 mmø: 325 mm

B O I L E R M AG X T Magneticfiltersforheatingsystemsofmedium-largedimensions.

• Fullstainlesssteelhousing• Assembyat360°• Neodymiummagnet• Guaranteesprotectionfromblackironoxide

t l c - t e c h n o l i s tc ata l o g u e | 2 0 1 6 - B o i l e r Pe r f o r m a n c e ® - 49

po

we

r f

lush

ing p

um

ps

de

sca

ling

Page 3: MAGNETIC FILTERS - BoilerMag...Magnetic filters for heating systems of medium-large dimensions. • Full stainless steel housing • Assemby at 360 • Neodymium magnet • Guarantees

B O I L E R M AG P U M P A DA P TO R 1 "

Boiler Mag 1” exclusive pump adaptor for an easy connection of the power flushing pumps, such as Hyperflush - Tran-sformer - Pulisci impianti, to clean the heating systems.

CODE CONNECTIONS PCS PER BOX

300910001 3/4" 1

a.

OPTIONAL

50-t l c - t e c h n o l i s tc ata l o g u e | 2 0 1 6 - B o i l e r Pe r f o r m a n c e ®