MAGDOS E / EL / FL MB 1 02 05 / 1 Lutz-Jesco GmbH Improved changes are always reserved without notice. Water meter Model MAGDOS FL(S) can be addressed by commercial contact water meters. In order to avoid disturbing influences or faulty pulses, the pump should not be mounted directly to the water counter. However, if an adapter is used providing for a distance of 50 mm a direct mounting is allowed. Preferably the pump should be mounted to the chemical tank or to a wall holder. The electronic system is designed for a maximum input frequency of 105 contacts per minute. The pulse sequence of the water meter should be designed accordingly. General In many processes in water and waste water treatment as well as in swimming pools metering pumps are required which can be adapted precisely to the corresponding process and the necessary functions regarding their metering capacity. Mete- ring pumps of the MAGDOS E/EL/FL series were designed such that you can select the appropriate pump for each specific task. MAGDOS E- Pump control for continuous operation at 100 strokes per minute. MAGDOS EL- Pump control for continuous operation at 100 strokes per minute allowing the connection of a self-monitoring low-level electrode. MAGDOS FL- Pump control for external control by means of water meter, controller and any other potential-free contacts. Per each incoming control contact the pump carries out a stroke. In order to protect the pump against overheating the control unit allows only a maximum frequency of up to 100 strokes per minute. As a protection against dry operation it is possible to connect a self-monitoring low-level electrode. Pumps of the EL and FL series are optionally also available with a fault indicator relay (type ELS and FLS) for a remote alarm signal if the level of the metering medium is too low or in the case of power failure. The metering capacity is in the range of 0.1 to 12 l/h. The exact metering output and the possible backpressure are shown in the feed characteristics in MB 1 02 05 / 5 and 6. Metering quantity adjustment is stepless and carried out via stroke length by actuating a threaded bush. The diaphragm stroke is produced by means of a DC solenoid. Reduction gears or rotating parts are not used which guarantees a high operational safety and maintenenance-free operation. All types are designed to meet the requirements of of the German Water and Gas Association and DIN 19635 and are also available as CSA/UL-versions.

Upload: dangtu

Post on 31-Mar-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

MB 1 02 05 / 1

Water meterModel MAGDOS FL(S) can be addressed bycommercial contact water meters. In order to avoiddisturbing influences or faulty pulses, the pumpshould not be mounted directly to the water counter.However, if an adapter is used providing for a distanceof 50 mm a direct mounting is allowed. Preferably thepump should be mounted to the chemical tank or toa wall holder. The electronic system is designed fora maximum input frequency of 105 contacts perminute. The pulse sequence of the water metershould be designed accordingly.

GeneralIn many processes in water and waste watertreatment as well as in swimming pools meteringpumps are required which can be adapted preciselyto the corresponding process and the necessaryfunctions regarding their metering capacity. Mete-ring pumps of the MAGDOS E/EL/FL series weredesigned such that you can select the appropriatepump for each specific task.

MAGDOS E-Pump control for continuous operation at 100 strokesper minute.

MAGDOS EL-Pump control for continuous operation at 100 strokesper minute allowing the connection of a self-monitoringlow-level electrode.

MAGDOS FL-Pump control for external control by means of watermeter, controller and any other potential-free contacts.Per each incoming control contact the pump carriesout a stroke. In order to protect the pump againstoverheating the control unit allows only a maximumfrequency of up to 100 strokes per minute. As aprotection against dry operation it is possible toconnect a self-monitoring low-level electrode.

Pumps of the EL and FL series are optionally alsoavailable with a fault indicator relay (type ELS andFLS) for a remote alarm signal if the level of themetering medium is too low or in the case of powerfailure.

The metering capacity is in the range of 0.1 to 12 l/h.The exact metering output and the possiblebackpressure are shown in the feed characteristicsin MB 1 02 05 / 5 and 6. Metering quantity adjustmentis stepless and carried out via stroke length byactuating a threaded bush. The diaphragm stroke isproduced by means of a DC solenoid. Reductiongears or rotating parts are not used which guaranteesa high operational safety and maintenenance-freeoperation.

All types are designed to meet the requirements of ofthe German Water and Gas Association and DIN19635 and are also available as CSA/UL-versions.

Page 2: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

MB 1 02 05 / 2

E EL (S) / FL (S) EL / FLPower supply 230 VAC 115 VAC 230 VAC 115 VAC 24 VDC**

50 Hz 60 Hz 50/60 Hz 50/60HzConnecting cable 2 m with 2m with UL/ 2 m with 2m with UL/ 2 m

gr. plug CSA plug gr. plug CSA plug

Power consumption at max. stroke frequnecy 30 W 33 W 30 W 33 W 30 WFuse T 1.6 A T 3.15 A T 1.6 A T 3.15 A T 10 AMax. stroke frequency 100 / minCsurrent consumption during stroke 2.3 A 3.6 A 2.3 A 3.6 A 12.6 ASafety class IP 65Insulation class FInput pulse length - at least 30 msExcitation time of solenoid per pulse 60 ms 80 ms 60 ms 80 ms 60 msFault indication relay with changeover contact - 250 VAC; 2.5 A -

30 VDC; 2.5 AVoltage at level electrode - 1 VDC 12 VDCVoltage at pulse input - 12 VDC 12 VDCMax. suction head 3 m Ws*Max. feed pressure 800 mbarMax. ambient temperature 40° CMax. metering agent PVC 35° Ctemperature PP, PVDF, st.steel 50° CWeight if metering head plastic approx. 2.7 kg

st. steel approx. 3.3 kg

Technical data

* E / EL / FL 8 max. 2m Ws* E / EL / FL 12 max. 1.2 Ws** only upon request

Page 3: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

MB 1 02 05 / 3

Sectional view of MAGDOS 01 - 12 l/h

Control panel MAGDOS 01 - 12 l/h

Pressure valve

Metering head

Suction valve

Drainage pipe

Separation chamber Control unitDrive

Calibration table

Stroke length adjuster

Locking screw

Green operating LED(goes out for a shortmoment during meteringstroke)

Power connection

Fault indicator relayConnecting cable

Lead-through for connectioncable "Pulse input" inthe case of direct water meter mounting

"Start" key

Red "low-level" LED

Level control connectionKack connector d3.5(Tank low level indication)

External control connection(Pulse input)

Page 4: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

MB 1 02 05 / 4

Dimensions

Wall holderPart No. 26502

Mounting kit with dowelsPart No. 25155

Adapter for mounting onstandard tanks (min. 60 l)Part No. 29775

for mounting on 45l tanksPart No. 32608

Pump basePart No. 21589

Adapter formounting on water meterPart No. 21801

For "L" dimensions, see table 1 02 05 / 8

approx.

appr

ox.

Page 5: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

MB 1 02 05 / 5

Discharge curves

scale scale

scale scale

scalescale

ml / pulse ml / pulse

ml / pulse ml / pulse

ml / pulse ml / pulse

Page 6: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

MB 1 02 05 / 6

Discharge curves

ml / pulse

scale

ml / pulse

strokes / min.

Page 7: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

MB 1 02 05 / 7

Pump 230 V~ 115 V~ 24 V= *

type: Control version Control version Control version

E EL FL ELS FLS E EL FL ELS FLS EL FL

01 32989 32957 32990 3299132992 32993 32998 33005 3301233019 33026 33032

03 32678 32685 32692 3269932706 32952 32999 33006 3301333020 32856 33033

07 32679 32686 32693 3270032707 32994 33000 33007 3301433021 33027 33034

2 32680 32687 32694 3270132708 32945 33001 33008 3301533022 33028 33035

4 32681 32688 32695 3270232709 32995 33002 33009 3301633023 33029 33036

8 32683 32690 32697 3270432711 32996 33003 33010 3301733024 33030 33037

12 32684 32691 32698 3270532712 32997 33004 33011 3301833025 33031 33038

Selection tablesIn order to offer the user a variety of pumps, thesehave been divided into the main functional groups.They can thus be assembled according to the user'sindividual requirements.

Drive Control unit Meteringhead

Valves Connections

The numbers of the pump drawing refer to thecorresponding selection table.

2 3

5

1

4

1 3

2

Drive Metering head

Control unit

* with automatic metering head venting; forfurther metering head ventings see MB 1 33 00

Control versionsE - internal operation, stroke length adjustableEL - as E, but with tank low-level controlELS - as EL, but with fault indicator relay

Pumptype: 230 V~ 115 V~ 24 V=

01 32956 33053 33058

03 32732 32953 32858

07 32719 33054 33059

2 32733 32943 32756

4 32720 33055 33060

8 32722 33056 33061

12 32723 33057 33062

1

2

4

5

4

3

5

Pump Materialtype: PMMA PVC PVDF 1.4571

01 32962 33321 -- --

03 -- 25188* 28115 25189

07 -- 25188* 28115 25189

2 -- 23809 28117 23812

4 -- 23809 28117 23812

8 -- 23810 28119 23813

12 -- 23811 29178 23814

2

FL - external pulse operation with tanklow-level control

FLS - as FL, but with fault indicator relay

Page 8: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

MB 1 02 05 / 8

4

Pump type Magdos 01 and 03 Magdos 07 up to 12 l/h

Housing material PVC PVDF 1.4571 PVC PVDF 1.4571

Sealing material Viton Viton Viton Viton Viton PTFE

Double-ball valves Suction valve 29434 33700 28459 20890 33703 24029

Discharge valve 29435 33701 28461 20891 33704 24030

Spring-loaded Suction valve -- -- -- 25087 34370 25089

Single-ball valves Discharge valve -- -- -- 25088 34371 25090

Valves

G 5/8 G 5/8G 5/8 G 5/8 G 5/8 G 5/8

da

dada

da

dida

di

da

di

L

L

L

L L

L

E"Ermeto"

connection

DThreaded

connection

CCementedconnection

BTubing clip connection

ATubing clip

(dimension 6/12 only)

DN Fig. Dim.Dim. Dim.L Part No.

di da PVC 1.4571 PVC PVDF 1.4571

4 A 4 6 24 -- 20975 29387 --

4 E -- 6 -- 45 -- -- 24959

6 A 6 8 30 -- 25176 -- --

6 A 6 9 30 -- 34925 -- --

6 A 6 12 13 -- 32980 33161 --

6 B 6 12 30 30 23092 -- 23093

6 C -- 10 15 -- 23087 -- --

8 C -- 12 15 -- 23089 -- --

6 D -- G1/4 20 20 23088 29179 22999

6 E -- 10 -- 54 -- -- 23090

8 E -- 12 -- 55 -- -- 23091

5 Connections

Page 9: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

MB 1 02 05 / 9

Installation example Legende

1 Metering pump Magdos E/EL/FL MB 1 02 05

2 Suction line MB 1 22 00

3 Electric agitator MB 1 36 00

4 Tank MB 1 20 01

5 Relief valve MB 1 25 01

6 Diaphragm shut-off valve MB 1 24 05

7 Injection nozzle MB 1 23 01

8 Pulsation dampener MB 1 27 01

9 Switch box

10 Water meter MB 1 37 01

11 Backpressure (loading) valve MB 1 25 01

12 Leak indication of diaphragm

"Leak check" MB 1 31 01

Order exampleA solenoid metering pump controllable by a watermeter is required for metering 0.4ml phosphate perstroke against 8 bar. Malfunctions are to be indicatedby remote signalling.

Pump selectionThe required 0.4 ml/stroke are achieved by a Magdos4 l/h with a stroke setting of approx. 60 %. Forexternal control and fault indication a Magdos FLS isthe proper pump. This pump type can be providedwith a suction line including a tank low-level controldevice.The pump is made up of the modules listed in tables1 to 5 as follows:

Magdos FLS 4 including:

Drive 230 V 32720

FLS control unit 32709

PVC metering head 23809

PVC suction valve 20890

PVC discharge valve 20891

4/6 suction connection 20975

6/12 discharge connection 32980

1

2

3

4

4

5

5

10

71

5 3

8

*

In the case of outgassing media, the pump should beplaced below the tank.

*

1224

9

6

11

Page 10: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

ET 1 02 05 / 1

ET 1 02 05 / 8

ET 1 02 05 / 6, 7

ET 1 02 05 / 5

ET 1 02 05 /6, 7

ET 1 02 05 / 8

ET 1 02 05 / 2

ET 1 02 05 / 3, 4

Spare Parts Lists

Spare Parts Kit

Includes: Pump Head Partsize material Seals Number

01 PVC, PMMA Viton 33066PVC, PMMA PTFE 33067

Diaphragm 03 PVC,1.4571 Viton 29742O-rings PVDF Viton 33853Gaskets PVC, 1.4571 PTFE 29758Valve balls PVDF PTFE 33858Valve seats 07 ... 4 PVC Viton 29746

PVDF Viton 33854PVC PTFE 29759PVDF PTFE 33859PVC EPDM 336961.4571 PTFE 29747

8 PVC Viton 29748PVDF Viton 33855PVC PTFE 29790PVDF PTFE 33860PVC EPDM 336971.4571 PTFE 29749

12 PVC Viton 29750PVDF Viton 33856PVC PTFE 29791PVDF PTFE 33861PVC EPDM 336981.4571 PTFE 29751

Page 11: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

ET 1 02 05 / 2

Item Description No.- Part No. according to model

No. off 01 03 07 2 4 8 12

1 Housing 1 27078

2 Diaphragm Rod 1 32713

3 Return Spring 1 29382

4 Screw 4 83613

5 Snap Ring 1 84154

6 Washer 1 84144

7 Cable Gland Screw 1 78786

8 Clamp + Gasket 1 78787

9 Solenoid 230 V ~ 1 32730 32714 32715

115 V ~ 1 32746 32748

24 V = 1 33063 32757

10 Retaining Screw 2 83514

11 Diaphragm Insert 1 32958 28849 28850 28851 28852

12 Diaphragm 1 81683 81424 81463 81464

13 Support Plate (spacer) 1 — 29312 23892 33897

14 Deflector Plate 1 22066

15 Damping ring 1 81680 78509

Drive Units

12 11 13 14 210 6 5 153 1 9

4

7, 8

Page 12: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

ET 1 02 05 / 3

Magdos EL / ELS Magdos FL / FLSMagdos E

Control Units

Page 13: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

ET 1 02 05 / 4

Control Unit

Item Type of controlNo. Description Qty. E EL FL ELS FLS

1 Casing cover 1 32668 32669 32670 32752 32753

2 Seal 1 81609

3 Socket head cap screw 4 83409

4 Electronic unit 230 V ~ 1 78628 78928 78929 79038 79039

115 V ~ 1 78931 78932 78933 79040 79041

24 V =1) 1 --- 78950 78953 ---

7 Stroke adjustment 01,03 1 32653

07, 2 1 32654

4 1 32655

8,12 1 32656

8 O-ring 1 80072

9 Screw 1 83746

10 Adjustment screw 1 32661

11 Main cable 230 V ~ 1 78997

115 V ~ 1 79013

24 V = 1 78956

12 Jack plug socket 1 --- 78946

13 Dummy plug 1 --- 29115

14 Screw 2 83653

16 Calibration table 03 1 32671

07 1 32672

2 1 32673

4 1 32674

8 1 32676

12 1 32677

17 "Primer" key 1 --- 78936 --- 78936

18 Remote control cable 1 --- 78947 --- 78947

19 Warning signal relay cable 1 --- 78800

20 Warning signal relay socket 1 --- 32652

21 Cable gland screw PG9 1 78934

22 Cable gland clamp PG9 1 78935

23 Insulating sleeve 3 78916

24 Switch accessories 1 --- 78942 --- 78942

25 Cover plug PG7 1 --- 78788

26 Gasket PG9 1 78943

27 Pressure screw PG7 1 --- 78786 --- 78786

28 Gland seal PG7 1 --- 78787 --- 78787

1) 24 V version on request2) for versions ELS and FLS: 2 off3) for versions ELS and FLS: 6 off

2)

2)

2)

3)

Page 14: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

ET 1 02 05 / 5

Metering heads

Magdos 01, PMMA Magdos 0 1 , PVC Magdos 03 und 07, PVCMagdos 2 . . . 12 , PVC including automaticMagdos 0 3 . . . 12 , PVDF metering head ventingMagdos 0 3 . . . 12 , 1.4571

Magdos 12, PVDF

Item Part-No. according to material

No Description Qty. PMMA PVC PVDF 1.4571

1 Diaphragm 01 1 32960 32919 — —

housing 03,07 1 — 25960 28114 22527

2, 4 1 — 21603 28116 21611

8 1 — 21222 28118 21612

12 1 — 22399 28689 21613

2 Socket head cap screw 4 83551 83409 83409 83622

3 Washer 4 84143 — — —

4 Venting screw 1 — 32142 — —

5 Valve ball 1 — 29778 — —

6 Nut 1 — 32143 — —

7 Pipe union 1 — 32845 — —

8 O-ring (only 01) 2 80618 80618 — —

1)

1) only available as assembly (Part No. 25188)

Page 15: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

ET 1 02 05 / 6

DN 3 Valves for Magdos 01 and 03 l/h

Suction Valve Discharge Valve

Item Description Part No. Material PVC PVDF 1.4571

No.

1 Valve body 20845 PVC 1 — —

28108 PVDF — 1 —

19289 1.4571 — — 1

2 Ball guide 29446 PVC 2 — —

29901 PVDF — 2 —

28460 1.4571 — — 2

3 Valve ball 81550 Ceramics 2 2 2

4 Valve seat 81549 Ceramics 2 2 2

5 Gasket 81371 Viton 1 — 1

81138 Viton — 1 —

6 O-ring 81384 Viton 1 — 1

7 Cover plug 19299 PVC 1 — —

28110 PVDF — 1 —

24031 1.4571 — — 1

8 Gasket 81551 Viton 1 1 1

9 O-ring 80618 Viton 2 2 2

Suction valve assembly 29434 33700 28459

Discharge valve assembly 29435 33701 28461

Page 16: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

ET 1 02 05 / 7

DN 4 Valves for Magdos 07 . . . 12 l/h

Double-ball Valves Spring-loaded Single-ball Valves

Pressure ValveSuction ValvePressure ValveSuction Valve

Item Description Part No. Material Double-ball valve Spring-loaded valve

No. PVC PVDF 1.4571 PVC PVDF 1.4571

1 Valve body 20845 PVC 1 — — 1 — —

28108 PVDF — 1 — — 1 —

19289 1.4571 — — 1 — — 1

2 Ball guide 19294 PVC 2 — — — — —

28109 PVDF — 2 — — — —

19293 1.4571 — — 2 — — —

24066 PVC — — — 1 — —

29386 PVDF — — — — 1 —

24067 1.4571 — — — — — 1

3 Valve ball 29778 Glas 2 — — 1 — —

18044 1.4401 — — 2 — — 1

25247 PTFE — 2 — — 1 —

4 Valve seat 81460 PVDF 2 2 2 1 1 1

5 Gasket 81371 Viton 1 — — 1 1 —

81677 PTFE — — 1 — — 1

81138 Viton — 1 — — — —

6 O-ring 81384 Viton 1 1 — 1 1 —

80617 PTFE — — 1 — — 1

7 Cover plug 19299 PVC 1 — — 1 — —

28110 PVDF — 1 — — 1 —

24031 1.4571 — — 1 — — 1

8 Valve spring 25081 Hastelloy — — — 1 1 1

9 O-ring 80013 Viton 2 2 — 1 1 —

80627 PTFE — — 2 — — 1

10 Gasket 81526 Viton 1 1 — 1 1 —

81585 PTFE — — 1 — — 1

Suction valve assembly 20890 33703 24029 25087 34370 25089

Discharge valve assembly 20891 33704 24030 25088 34371 25090

Page 17: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

E /

EL

/ F

L

ET 1 02 05 / 8

Connections

Conn. assembly Spare partsType Material Size Part No. Item Description Part No.

A PVC 4/6 20975 1 Union nut 881162 Connection 880123 Clamping ring 880034 Union nut 88004

5/8 21851 1 Union nut 820872 Connection 218524 Union nut 19397

6/8 25176 1 Union nut 820872 Connection 313704 Union nut 19397

6/12 32980 1 Union nut 881162 Connection 325723 Clamping ring 32571

PVDF 4/6 29387 1 Union nut 281202 Connection 880283 Clamping ring 880034 Union nut 88004

6/12 33161 1 Union nut 881172 Connection 325723 Clamping ring 32571

B PVC 5/8 28106 1 Union nut 820872.1 Hose connection 182663 Hose clamp 82398

2.2 Cem. con. part 820131.4571 23093 1 Union nut 19303

2 Hose connection 180453 Hose clamp 82398

PVC 6/12 23092 1 Union nut 820872 Hose connection 180423 Hose clamp 82398

C PVC 10 23087 1 Union nut 820872 Cemented conn. 82014

12 23089 1 Union nut 820872 Cemented conn. 82013

D PVC G 1/4 23088 1 Union nut 820872 Threaded conn. 82185

PVDF 29179 1 Union nut 281202 Threaded conn. 28292

1.4571 22999 1 Union nut 193032 Threaded conn. 82186

E 1.4571 6 24959 1 Union nut 880342 Cutting ring 88035

8 29371 1 Union nut 880362 Cutting ring 88037

10 23090 1 Union nut 880382 Cutting ring 88039

12 23091 1 Union nut 880402 Cutting ring 88041

2

231

1

34

3

2

1

2

1

2

1

1

2

Page 18: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 1

Operating and Maintenance Instructions

metering pump fails. We recommend installing leakageprobes and containment tanks.Metering pumps are produced according to highestquality standards and have a long service life.Nevertheless some parts are subject to wear (e.gdiaphragm, valve seats, valve balls). To ensure longoperating life, visual checks are required regularly.Operating and maintenance personnel must be ableto access the pump easily. Periodic maintenanceprotects the metering pump against shutdowns.To increase the metering accuracy and reliability, werecommend using additional fittings. These includebackpressure valves, relief valves, leakage probes,and chemical low level indicators, as shown in figures1 to 3.Always use appropriate tools for the installation ofplastic connecting parts. In order to avoid damage,never apply excessive force; plastic parts (especiallyPVC parts) can be screwed and unscrewed moreeasily if the thread is lubricated with vaseline orsilicone grease before.Note: For this purpose, the compatibility with thechemical to be metered must be checked.MAGDOS metering pumps with integrated levelcontrol function are equipped with a short-circuit jackplug which must be removed before connecting alevel control by means of a jack plug. To keep theprotection class, screw a PG plastic sleeve on thejack plug. The required PG sleeve is part of the levelcontrol (also in combination with a suction line).Mounting the metering pump directly on the watermeter may result in noise level amplification. In thiscase, it is recommended to mount the pump onseparate wall brackets which, for the same reason,should be fixed to outer walls instead of interior wallswith adjacent occupied rooms. It is also possible tomount the pump directly on the metering supplytank.Ambient temperatures exceeding 40°C are notpermitted. Radiant heat of apparatus and heatexchangers must be kept in limits allowing the pumpto sufficiently dissipate its own heat. Exposure todirect sunlight should be avoided especially for mete-ring pumps with plastic housings because the blackplastic material can be damaged. If the pump isinstalled outside, provide an enclosure to protect itagainst weather.Wiring of the MAGDOS metering pump must becarried out by a specialist according to the localregulations. Normally the MAGDOS is connectedwith a safety plug. The electrical data for all MAGDOSdata is listed in Table 14 "Technical data".Note: The MAGDOS metering pumps are not suitedto be used in explosive environments.Do not lay signal cables of water meters or0(4)...20mA controls parallel to high-voltage current

Keep the operating instructions of the meteringpump and the accessories readily accessible.

List of contents1. General2. Scope of delivery3. Installation4. Injection fitting installation5. Safety instructions6. Installation example7. Startup8. Replacing the diaphragm9. Drive solenoids

10. Correction of stroke length setting11. Control panel12. Circuit diagrams13. Functional overview14. Technical data15. Troubleshooting

1. GeneralSolenoid metering pumps can be used in manyapplications. It is a particular advantage that they canbe controlled proportionally to water meter contacts.They are also suited to be used as regulating units inautomatic control systems. See table 13 for variouscontrol types and monitoring facilities.

2. Scope of deliveryBe careful when unpacking the metering pump andpossible accessories in order not to miss smallparts. Compare the scope of delivery to the deliverynote. If there are any discrepancies, try to find out thereason.

3. InstallationFor selection of a pump during construction of a plantas well as for installation and operation, the localrules must be observed. This applies to the selectionof suitable pump materials, the handling of thechemicals and the electrical installation. At thesame time the technical data of the metering pumpaccording to table 12 must be considered, and theplant must be designed correspondingly (e.g. pressureloss in lines depending on nominal diameter andlength).Both, the designer and the user are responsible tomake sure that the whole plant including the mete-ring pump is constructed so that neither plantequipment nor buildings are severely damaged in thecase of chemical leakage due to the failure of wearparts (e.g. diaphragm rupture) or burst tubing. Whenconstructing chemical plants, the installation mustbe carried out so that no consequential damagesappear which are unreasonably high even if the

Page 19: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 2

or power supply lines. Supply and signal lines mustbe laid in separate channels. In the case of junctions,a 90° angle is required. If the water meter controlcable is more than 2 meters long, it must be shielded.To avoid incorrect metering after the process isfinished, provide an electric and hydraulic interlockingsystem.

4. Injection fitting assemblyInjection nozzles prevent the liquid from returning tothe pump by using either a spring-loaded ball valve ora hose valve. We recommend vertical injection frombottom to top to allow air to escape thereby avoidingchemical precipitation. Experience with the particularmetering chemical and all appropriate characteristicsmust be taken into account.

5. Safety instructions⇒ When working on chemical equipment, observethe local safety rules (e.g. wear personal protectiveclothes).⇒ Before working on the metering pump and plant,disconnect it from the main power supply and secureit against reconnection. Before the voltage supply isswitched on again, the metering lines must beconnected so that chemical left in the metering headcannot spurt out.⇒ The metering head of the pump as well asconnections and lines in the plant may be underpressure. Working on the metering plant requiresspecial safety precautions and may only be carriedout by instructed technical personnel.⇒ Before startup, all screwed connections must bechecked for correct tightness and, if necessary,must be tightened up using appropriate tools.⇒ If connections at the metering head areunscrewed during operation for venting or otherreasons, leaking chemical must be removedcompletely. This is the only way to avoid the dangerof physical injury and corrosion at the meteringpump. Leaking chemical may also destroy thediaphragm at its mounting points.⇒ When changing the chemical, check whether thematerials used for the metering pump and the otherplant parts are chemically resistant.If there is the danger of a chemical reaction betweendifferent media, a thorough cleaning first ismandatory.⇒ After adjustment work at the control panel of theMAGDOS, the control cover must be closed again(the cover is not available for all MAGDOS types).Otherwise protection class IP 65 cannot beguaranteed.⇒ After changing the electrical connections, e.g.removing the level control, the PG cable gland nutmust be tightened in order to ensure the protectionclass of the pump.

Injection fitting

Page 20: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 3

6. Installation example

Fig.1

MAGDOS DE/DX 40 and DE/DX 100 can only bemounted parallel to the wall.

Fig. 3

Fig. 2

1 MAGDOS MB 1 02 002 Suction line with integrated

level control MB 1 22 013 Hand mixer MB 1 36 024 Chemical tank MB 1 20 015 Leakage probe for monitoring

the diaphragm MB 1 31 016 Relief/safety valve MB 1 25 017 Shutoff valve for isolating the

pump from the plant MB 1 24 018 Back pressure valve for max.

metering accuracy MB 1 25 019 Injection nozzle with non-return

valve MB 1 23 0110 Venting as separate part or MB 1 33 02

integrated in the metering head MB 1 33 0311 Water meter with contact unit MB 1 37 0112 Pulsation dampener for reducing

pressure peaks and smoothingthe flow MB 1 27 01

13 Separation chamberis recommended if the mediacould damage the pump in thecase of a diaphragm failure MB 1 28 01ATTENTION!Leakage must be dischargedinto a collection funnel usinga short inclining drain pipe(and can then be returned tothe chemical tank).The outlet of the drain pipemust be visible in order toactually see the leakage.

14 Priming aidThis equipment allows easystartup of small pumps in particular.The entrained gas serves as apulsation dampener. MB 1 33 01

15 Water meter spacer MB 1 37 01ATTENTION!The spacer is required toavoid that the drive solenoidaffects the water metercontact.

16 Wall bracket MB 1 32 0017 Tall or short adapter for tank

mounting

Page 21: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 4

8. Replacing the diaphragmThe diaphragm can be easily removed and replacedaccording to the exploded drawing. To facilitateremoval of the old diaphragm, first set the stroke to"0" while pump is running. If the diaphragm rod isturning it can be stopped by means of a locking pin(JESCO P/N 29379). The drilled hole in the diaphragmrod can be accessed through the drainage channel.

Suction valve Drainage tubeMetering head Snap ring

Grease diaphragm rod with Molycote.

The deflector plate must rest in the diaphragm rodgroove. Ensure that it is not clamped between thediaphragm rod and the support plate. If the diaphragmis supplied with a support plate, clean or replace thelatter before mounting it.

9. Drive solenoidsDepending on the pump version, the solenoid designdiffers. The following table shows the coil resistanceat 20°C room temperature. With perfect coils, theresistance tolerance should not exceed +/-5%. If theresistance is substantially lower, there is a short inthe coil, if the resistance is indefinitely high, the coilis fused or the wire is broken.

7. Startup

ATTENTION!Adjust the stroke length only while pump isrunning.

1. For first startup, set pump to maximum strokefrequency or press start key and allow to prime. For this purpose, it is advisable to set thestroke to "10". If the pump doesn't prime, removedischarge valve and pour water or chemical (ifharmless!) into head. Mount the valve and allowto prime again (priming aid, item 14, fig. 2 isrecommended).

2. If a venting facility is integrated in the meteringhead or is available as separate unit, open it andwait until liquid escapes. Then close it again. Inthe case of effervescent liquids allow the liquidto escape permanently (approx. 1 drop for1...3 strokes).

3. When correct operation is achieved, set torequired output and lock adjusting knob. Referto the calibration table attached to the pump toget the stroke length setting for a selected output(ml/pulse). The back pressure influences aretaken into consideration in the table, andintermediate values must be interpolated.Depending on the installation and the chemicalsused, these values may differ and must bechecked under operating conditions.

Example:

Required metering capacity: 0.8 ml/pulse against8 bar.The table says H=9.9. Adjust knob "H" accordinglywhile the pump is running.

4. In the case of externally actuated pumps (e.g. bywater meters), set pump to "external". Initiatethe water flow by opening a water valve andcheck pump pulse rate.

5. The manufacturer of the metering equipment isnot responsible for damages due to excessive orlow flow rates resulting from faulty pump settingsor incorrect and insufficient installation ofperipheral fittings.

Washer

Return spring

Groove fordeflector plate

Discharge valve

Diaphragm Deflector plate

Support plate if required

Drilled holeforlocking pin

Page 22: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 5

3. Attach knob so that the indicator is pointing to "0"and, with the knob tightly held, fasten screw.

4. Run pump according to a setting of the outputtable. If there is a major discrepancy, correct theknob position.

ToothingPhilipshead screw

Test check for drive solenoids

SolenoidMark

a

b

c

Protective conductor

The resistance between a-c and b-c is infinite.

Resistance of cold coils (20 °C)X=Solenoid Mark

10. Correction of stroke length settingTo avoid excessive metering, the metering line mustbe returned to the chemical tank during setting (ifnecessary).

1. Operate pump with automatic control (ifnecessary, by pressing the start key for FL).

2. Regardless of the indicator position, loosen thefastening screw and turn the stroke lengthadjustment knob counterclockwise until the pumpno longer delivers or, in the case of no-pressuredelivery, the flow rate has reached the minimum.If zero delivery could not be attained becausethe knob reached the stop position, remove theknob after loosening the fastening screw, turn itto the right and reattach it. Then turn again to theleft until the pump no longer delivers.

Stroke lengthadjustment knob

nidioneloS %5-/+]W[ecnatsiseRnoisrevpmup tab-aneewteb

~V032 X ~V511 X =V42 XLF,LE,E LF,LEylno

XD,ED 311 M 03 R 9.1 Y3,0...1,0LF,LE,E LF,LEylno

XD,ED 311 N 03 T 9.1 Z2...7,0

LF,LE,E LF,LEylnoXD,ED 19 O 03 T 9.1 Z21...4XD/ED

001...02 15 G 41 H - -

Ω

Page 23: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 6

Calibration table

"Start" keyfor FL

Chemical low lightsignal for El and FL

Level probe forEL and FL

External controlconnection for FL

Warning alarmrelay cable forEL and FL

Power supply

Operating light

Stroke lengthadjustment

Locking screw

11.1 Control panel

E, EL and FL pumps

Page 24: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 7

11.2 Control panel

Magdos DE

Magdos DX

1

1 Power supply cable, 2 m, with plug

2 Cable for warning alarm relay, 1.5 m

3 3.5 mm jack for level probe connection;can be used by 2-pin plug for simple lowlevel indication or by 3-pin plug for low levelindication with alarm signal.

4 a Cable/connection socket for pulse input4 b Cable/connection socket for pulse and d.c.

signal input

5 Adjusting knob for metering capacity perstroke

6 Locking screw

7 Stroke frequency ajdustment withchangeover switch for external control

8 Digital display (optional)

9 a Red LED- blinks slowly in the case of alarm signaling

and lights permanently if the tank is empty.Pump is then stopped automatically.

9 b - like a, plus fast blinking if, in the case ofd.c. 4...20mA signal control, the inputsignal is less than 4mA (e.g. due to cablerupture).

- blinks slowly if selector switch (12) is setto "0" (pump is not metering).

10 Green LEDlights if power supply voltage is applied andblinks off during the metering stroke.

11 Calibration table

12 Selector switch for external control

Pulse 1:1

Pulse division 2 / 4 / 8 / 16 / 32 / 64

Pulse multiplication 2 / 4 / 8 / 16 / 32 / 64

Input signal 0...20mA or 4...20mA

Pump stop "0"

Page 25: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 8

12.2 Circuit diagram

EL and FL pumps 24V

12.1 Circuit diagram

E pumps

Power supply230V/50Hz or115V/60HzSolenoid

Solenoid

Level control

to warning alarm circuit board

Start key

Pulse signal input

red

brown

bro

wn

blue

red

white

Page 26: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 9

12.3 Circuit diagram

EL and FL pumps230V/50Hz and 115V/60Hz

Solenoid

Startkey

Soldering jumpers forstroke frequency:Only jumper maybe connected at atime!

one

Relay inversion:Remove jumper FSand connect jumperNFS.

Pulseinput

brown

white

red

red

NFS FS

Level control Powersupply

blac

kbr

own

blue

brown/black closed in the case of operation

red

red

gree

n/ye

llow

1002550

Page 27: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 10

12.4 Circuit diagram

DE- / DX pumps230 V / 50/60 Hz

115 V / 50/60 Hz

Relay reversal: Open upper solder jumper, close lower one.

Display

Solenoid

green/yellow

Power supply

blue

brow

nbl

ack

Warning alarm: brown/blue closed in the case of failure brown/black closed during operation

Level control

blue

red

blac

k

DE/DX 20...100black

red

whitebrown

Signal input

DE/DX 01...12

brownwhite

Relay reversal: Open upper solder jumper, close lower one.

Display

Solenoid

green/yellow

Power supply

Warning alarm: red/white closed in the case of failure red/black closed during operation

Level controlSignal input

whi

tere

dbl

ack

brow

n

blue

blue

blue

redre

d

blac

k

Page 28: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 11

13. Functional overviewPump type

Features Magdosx = Standardo = Optional E EL FL DE DXVoltage 230 V~/50 Hz x x x x x

115 V~/60 Hz x x x x x24 V = x x

Internal control x x x xExternal contact x x xcontrol 0...20mA xby 4...20mA xPulse division/multiplication xLow level indication via LED x x x xAlarm via warning relay o o o oLevel control with alarm signal x xDigital display o o

14. Technical data

In the case of 0(4)...20mA signal control (only MAGDOS DX) it is important that the signal line doesn't come into contactwith ground, if the signal source is not isolated (individual voltage separators upon request). The linearity ofconverting the signal into stroke frequency is +/- 3%.

Type E EL(S)/FL(S) EL/FL DE/DX 01...12 DE/DX 20...100V 230 AC 115 AC 230 AC 115 AC 24 DC 230 AC 115 AC 230 AC 115 AC

Electrical Connection Hz 50 60 50/60 50/60 - 50/60 50/60 50/60 50/60Power supply cable with plug m 2Power consumption W 30 33 30 33 30 30 33 70 66Max. stroke frequency min-1 100 70Current consumptionduring stroke A 2.3 3.6 2.3 3.6 12.6 2.3 3.6 4.1 7.4Fuse A T1.6 T3.15 T1.6 T3.15 T10 T0.8 T1.6 T2 T4Protection class IP 65Insulation class FInput pulse duration m s - at least 30Solenoid exication timeper pulse m s 60 80 60 80 60 60 80 160 190Warning alarm relay with V - 250 AC,30 DC - 250 AC,30 DCchangeover contact A - max. 2.5 - max. 2.5Voltage atlevel connection V - 1DC 12 DC 5 DCVoltage atpulse input V - 12 DC 5 DCInput impedence0(4)...20mA Ohm - 150Max. suction hight1) mWs 3 1,2Max. feed pressure 2) mbar 800 500Max. ambienttemperature °C 40Max. metering medium PVC °C 35temperature PP,PVDF,E-St. °C 50Weight, with plastic kg 2.7 2.9 12.5 3)

metearing head: SS kg 3.3 3.5 20 3)

1) MAGDOS 8 max. 2 m WsMAGDOS 12 max. 1.2 m Ws

2) MAGDOS 40 max. 250 mbarMAGDOS 100 max. 150 mbar

3) MAGDOS 20 10,5 or 12 kg

Page 29: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 12

NATURE OF PROBLEM POSSIBLE CAUSE RECOMMENDED ACTION

Pump not delivering or Valves leaking or blocked. Clean valves and bleed pump.output too low. See also start-up of pump

BW 1 02 98 / 4.Valves incorrectly installed. Reassemble valves.

Ensure that valve ballsare located above valveseats.

Suction valve or suction line Clean and seal suction line.leaking or blocked.Suction lift too high. Install pump at lower position.

Install pulsation dampener onsuction side.Install priming aid.

Viscositiy too high. Install spring-loaded valves.Enlarge line cross-section.Use special metering head.-----> Contact JESCO.

No stroke movement Pump set to zero stroke. Correctly adjust pump stroke.observed. Diaphragm return spring broken. Replace spring.

Fuse blown, LEDs off. Check power supply line,replace fuse (section 14).

Solenoid defective. Check coil resistance and isolation;replace solenoid, if required.

Red low liquid level Feed tank empty; level control or Fill tank or check suction line.indication LED on. dummy plug incorrectly inserted.Frequent diaphragm No support plate. Replace diaphragm with supportfailures. ATTENTION! plate. When replacing diaphragm,

Not all diaphragms are supplied check if deflector plate or diaphragmwith support plate (acc. to spare rod have been corroded by pumpedparts list). See section 8, "Replacing fluid.the diaphragm", BW 1 02 98 / 4.Diaphragm was not screwed Screw in new diaphragm as far asinto the diaphragm rod as far stop. Support plate must then beas stop. clamped between diaphragm and

diaphragm rod.Back pressure to high Check system. Clean blocked(measured at discharge injection nozzle. Reduce pressureconnection of pump). peaks resulting from extremely

long tubes by installing pulsationdampeners.

Media sediment in Flush metering head.metering head.

Pump delivering too much. Pressure on suction side too high. Install back pressure valve(Pump siphoning). in discharge line.Stroke stop shifted. Readjust stop (see item 10).

Stroke frequency too high. Reduce frequency.

If the problem cannot be corrected on the basis of the above data, return the pump to the factory or contact our After-Sales Service for further measures. Repairs will be carried out immediately.

15. Troubleshooting

Page 30: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

MB 1 02 20 / 1

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

GeneralMAGDOS DE / DX solenoid metering pumps combinethe digital technology of state-of-the-artmicroprocessors with high-quality mechanics. Due toits versatility in the area of external control, the newMAGDOS series is very flexible. The pump can besupplied with a digital display upon request. The displayshows the different operating conditions and possibleerror messages.

The new MAGDOS is available in two basic versionswith the following features:

MAGDOS DE- Internal control with continuous stroke frequency

adjustment from 0 to 100 strokes per minute forDE 01...12 and 0...70 strokes per minute forDE 20...100

- Changeover function to external pulse control bywater meter or other voltage-free contacts

- Connection for level control with alarm signal

MAGDOS DX- Internal control with continuous stroke frequency

adjustment from 0 to 100 strokes per minute forDX 01...12 and 0...70 strokes per minute forDX 20...100

- Changeover function to external control by0/4...20 mA standard signal

- Changeover function to external pulse control bywater meter or other voltage-free contacts

- Pulse multiplication with factors 2/4/8/16/32/64- Pulse division with divisors 2/4/8/16/32/64- Connection for level control with alarm signal

As an alternative, both versions can be supplied withwarning alarm relay and digital display. The meteringcapacities range between 0.1 l/h at 10 bar and115 l/h at 1.5 bar. Refer to MB 1 02 20 / 6-7 for exactperformance curves, the output per pulse is set bychanging the stroke length via the stroke adjustmentknob.

The pumps are designed to meet the requirements ofDVGW-DIN 19635 and CSA/UL.

Magnetic driveThe stroke movement of the metering diaphragm isproduced by a d.c. solenoid. Due to the infinitelyadjustable stroke stop, it is possible to set a stroke of0-6 mm, depending on the pump size. Reduction gearsor rotating parts are not used, resulting in high reliabilityand low maintenance work. The armature runs in amaintenance-free DU bushing with PTFE coating andadditional silicone grease lubrication.

Control unitThe main part of the control unit is a microprocessorwhich controls the stroke frequency with digitalaccuracy. The various control possibilities allow thepump to be adapted to practically all requirements ofhome water supply, water and waste water treatmentas well as industrial pocesses. The electronic controlunit is available in two basic versions with functionsdescribed below.

Functions X=standard Magdos DE Magdos DXO=optional

Level control with alarm signal X X

Low level indication X X

Warning alarm relay O O

Internal control 0...100% X X

External control contact X X

0...20 mA - X

4...20mA - X

Pulse division / multiplication - X

Stroke adjustment X X

Digital display O O

Page 31: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

MB 1 02 20 / 2

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

Water metersThe MAGDOS DE/DX can be controlled by any watermeter with voltage-free contacts. For water meterswhich pulse too fast or too slow for the pump, the pulsedivision or multiplication function of the pump can beused to adapt the pump to the water meter. In the caseof pulse division, the maximum stroke frequency isrestricted (see MB 1 02 20/4).

In order to avoid interference or false pulses, do notmount the pump directly on the water meter. If adapterswhich ensure a distance of 50 mm are used, directmounting is possible. With this kind of installation, pulsedivision or multiplication must not be used. It isrecommended to mount the pump on the chemical tankor to the wall.

Drain pipe

DE/DX 01...12 DE/DX 20...100Electrical connection 230 V~ 115V~ 230V~ 115V~

50/60 Hz 50/60 Hz 50/60 Hz 50/60 HzPower supply cable 2 m with 2 m with UL/ 2m with 2m with UL/

standard plug CSA plug standard plug CSA plugPower consumptionat max. stroke frequency 30W 33W 70W 66WFuse T 0.8 A T 1.6 A T 2 A T 4 AMax. stroke frequency 100 70Current consumption during stroke 2.3 A 3.6 A 4.1 A 7.4 AProtection class IP 65Insulation class FInput pulse duration min. 30 msSolenoid excitation time per pulse 60ms 80ms 160ms 190msWarning alarm relay with 250V AC, 2.5 Achangeover contact 30 V DC, 2.5 AVoltage to low level probe 5 V DCVoltage to pulse input 5 V DCImpedance to 0/4...20mA input 150 ΩMax. suction lift 3m Ws* 1.2m WsMax. ambient temperature 40° CMax. temperature of medium PVC 35° Cto be metered PP, PVDF, SS 50° CWeight Plastic approx. 2.9 kg 12.5 kg**Head Stainless steel approx. 3.5 kg 20 kg**

* DE / DX 8 max. 2m Ws **DE/DX 20 10.5 kg or 12 kg,* DE / DX 12 max. 1.2m Ws respectively

Technical data

Cross section of MAGDOS DE / DX 01...12Separation chamber Magnetic drive Control unit

Suctionvalve

Meteringhead

Dischargevalve

Page 32: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

MB 1 02 20 / 3

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

Power supply cable, 2 m, with plug

Cable for warning alarm relay, 1.5 m

3.5 mm jack for level probe connection;can be used by 2-pin plug for simple low levelindication or by 3-pin plug for low level indicationwith alarm signal.

Cable or connector socket for pulse inputCable or connector socket for pulse and d.c. signalinput

Adjusting knob for metering capacity per stroke

Locking screw

Stroke frequency adjustment with changeoverswitch for external control

Digital display

Red LED- blinks slowly in the case of alarm signaling and

lights permanently if the tank is empty. Pump isthen stopped automatically.

- like a, plus fast blinking if, in the case of4...20 mA d.c. signal control, the input signal isless than 4 mA (e.g. due to a cable rupture).

- blinks slowly, if selector switch (12) is set to "0"(pump is not metering).

Green LEDlights if power supply voltage is applied and goesout for a short time during the metering stroke.

Calibration table

Selector switch for external controlPulse 1:1 1Pulse division 2 / 4 / 8 / 16 / 32 / 64Pulse multiplication 2 / 4 / 8 / 16 / 32 / 64Current input 0...20 mA or 4...20 mAPump stop "0"

Control panel MAGDOS DX

Control panel MAGDOS DE 1

2

3

4a4b

5

6

7

8

9a

9b

10

11

12

Page 33: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

MB 1 02 20 / 4

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

External controla) ContactIn order to protect the pump against overheating, themaximum input frequency is limited to 70 or 100 pulses/minute. If the input frequency is higher, each third orfourth metering stroke is not carried out. Thereforeexternal pulse transmitters should be designed so thatthe maximum stroke frequency is not exceeded.

b) Contact with pulse division/multiplicationIncoming control pulses can be divided or multipliedby setting the selector switch correspondingly.

1) Ratio 1:1

2) Pulse multiplicatione.g. setting to 8-- one control pulse results in 8 meteringstrokesNote: The metering strokes are carried outat maximum stroke frequency.

3) Pulse divisione.g. setting to 16-- one metering stroke is carried out after16 incoming control pulses.

When setting pulse division to 32, the maximum strokefrequency is reduced to 70 strokes/min.; with divisor64, it is max. 36 strokes/min..

c) Standard signal 0/4...20mATo control the pump by standard signal 0/4...20 mA,operate the selector switch. The linearity of convertingthe signal into stroke frequency is +/- 3%. If the signalsource is not isolated, it must be ensured that the signalline does not come into contact with ground (separateisolators available upon request!).Note: To avoid accidental metering after the processis finished, provide an electric or hydraulic interlockingsystem.

2)

1)

3)

Level controlTo protect the pump against dry operation, level probeswith or without alarm signaling can be connected(3.5 mm jack). They also provide self-diagnostics. Adummy plug is inserted if no level switch is used.

Warning alarm relayWith the warning alarm relay (voltage-free changeovercontact), the following alarm states can be transmitted:

- "Tank empty" if a simple level probe isconnected.

- "Tank almost empty" if a level probe with alarmsignaling is connected. (In this case "Tankempty" cannot be indicated.)

- If, for d.c. signal control with 4...20mA, the inputsignal is less than 4mA (e.g. cable breakage).

- Power supply failure

Digital displayThe display indicates the different operatingconditions and possible error messages.

Display Meaning080 Stroke frequency of 80 per minute

with operating condition internalcontrol or d.c. signal control

1.1 Operating condition external controlwith contact ratio 1:1

1.16 Operating condition external controlwith pulse multiplication factor 16

8.1 Operating condition external controlwith puls division divisor 8

E - L "Tank empty" message

I - E Input signal < 4mA with4...20mA control(e.g. cable breakage)

OFL Input signal > 20mA with0/4...20mA control

OFF with selector switch set to "0"

Page 34: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

MB 1 02 20 / 5

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

Dimensions DE/DX 01...12

Wall bracketPart No.: 26502

Mounting kitwith dowelsPart No.: 25155

Pump basePart No.: 21589

AdapterPart No.: 21801

Adapter for mounting onstandard tanks (min. 60l)Part No.: 29775

for mounting on 45l tanksPart No.: 32608

For "L" dimensions, see MB 1 02 20 / 10.

approx.

approx.

Page 35: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

MB 1 02 20 / 6

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

Dimensions DE/DX 20...100

Wall bracketPart No.: 26502

Dimensions

Model Material A B C DDE/DX PVC 155 89 310 8720 1.4571 135 89 310 87DE/DX PP 280 152 345 10540/100 1.4571 280 148 310 105

For "L" dimensions, see MB 1 02 20 / 11.

Pump basePart No.: 21589

Page 36: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

MB 1 02 20 / 7

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

Performance curvesThe performance of the pump depends on theviscosity of the medium and hydraulic installationconditions. The curves refer to water at 18° C and asuction lift of 0.6 m.

scale

ml/pulse

scale

scale

ml/pulse

ml/pulse

scale

ml/pulse

scale

ml/pulse

scale

ml/pulse

Page 37: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

MB 1 02 20 / 8

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ml/pulse

scale scale

scale scale

ml/pulse

ml/pulse ml/pulse

strokes/min

ml/pulse

Page 38: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

MB 1 02 20 / 9

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

Selection tablesIn order to be able to offer the user a variety of pumps,these have been divided into the main functionalgroups. They can thus be assembled according to theuser's individual requirements.

Drive Control unit H e a d

Valves Connect ions

The numbers on the pump drawing refer to the relevantselection tables.

1

4

2

5

3

5

4

3

4

5

1

2

4 Valves

Housing material PVC PP PVDF 1.4571Sealing material Hypalon Viton Hypalon Viton Viton Hypalon Viton AF PTFE01... Double-ball S — 29434 — — 33700 — 28459 — —03 valves D — 29435 — — 33701 — 28461 — —07... Double-ball S — 20890 — — 33703 — — — 2402912 valves D — 20891 — — 33704 — — — 24030

Spring-loaded S — 25087 — — 34370 — — — 25089valves D — 25088 — — 34371 — — — 25090

20 Double-ball S 18187 18185 — — — — — 26967 —valves D 18188 18186 — — — — — 26968 —Spring-loaded S 25161 25162 — — — — — 28775 —valves D 27516 27517 — — — — — 28776 —

40... Double-ball S — — 26841 26842 — 26843 27652 29694 —100 valves D — — 27356 27357 — 27358 27655 29695 —

Spring-loaded S — — 26845 25707 — 26844 25797 29696 —valves D — — 27353 27354 — 27355 27654 29697 —

1 Dr i ve

P u m p etype: 230 V~ 115 V~

0 1 32956 330530 3 32732 329530 7 32719 33054

2 32733 329434 32720 330558 32722 33056

1 2 32723 330572 0 34338 343414 0 34339 34342

1 0 0 34340 34343

3

* with automatic head venting;for further head venting equipment,see MB 1 33 00.

H e a d

P u m p Materialtype: PMMA PVC PVDF 1.4571

P P 0 1 32962 —— — – 0 3 — 25188*2811525189 –

0 7 — 25188* 28115 25189 –2 — 23809 28117 23812 –4 — 23809 28117 23812 –8 — 23810 28119 23813 –

1 2 — 23811 29178 23814 –2 0 — 23909 23911 23911 –4 0 — — 23727 23727 23721

1 0 0 — — 23728 23728 23722

Page 39: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

MB 1 02 20 / 10

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

2 Control unit

P u m p Control typesVoltage type: D E DE...S DE...D DE...SD DX DX...S DX...D DX...SD230 V ~ 0 1 33931 33938 33945 33952 33959 33966 33973 33980

0 3 33932 33939 33946 33953 33960 33967 33974 339810 7 33933 33940 33947 33954 33961 33968 33975 33982

2 33934 33941 33948 33955 33962 33969 33976 339834 33935 33942 33949 33956 33963 33970 33977 339848 33936 33943 33950 33957 33964 33971 33978 33985

1 2 33937 33944 33951 33958 33965 33972 33979 339862 0 34290 34293 34296 34299 34302 34305 34308 343114 0 34291 34294 34297 34300 34303 34306 34309 34312

1 0 0 34292 34295 34298 34301 34304 34307 34310 34313115 V ~ 0 1 33987 33994 34001 34008 34015 34022 34029 34036

0 3 33988 33995 34002 34009 34016 34023 34030 340370 7 33989 33996 34003 34010 34017 34024 34031 34038

2 33990 33997 34004 34011 34018 34025 34032 340394 33991 33998 34005 34012 34019 34026 34033 340408 33992 33999 34006 34013 34020 34027 34034 34041

1 2 33993 34000 34007 34014 34021 34028 34035 340422 0 34314 34317 34320 34323 34326 34329 34332 343354 0 34315 34318 34321 34324 34327 34330 34333 34336

1 0 0 34316 34319 34322 34325 34328 34331 34334 34337

DE: Internal pulse 0...100 or 0...70 strokes/min, external pulse 1:1, low level with alarm signaling and master alarmDE...S: same as DE plus warning alarm relayDE...D: same as DE plus digital displayDE...SD: same as DE plus warning alarm relay and digital display

DX: Internal pulse 0...100 or 0...70 strokes/min, external pulse 1:1, pulse division and multiplication,0/4...20mA signal input,low level with alarm signaling and master alarm

DX...S: same as DX plus warning alarm relayDX...D: same as DX plus digital displayDX...SD: same as DX plus warning alarm relay and digital display

BHose liner

ATubing

connection

5 Connections DE/DX 01...12

D N Fig. Dim. Dim. Dim. L Part No.d i d a PVC 1.4571 PVC PVDF 1.4571

4 A 4 6 2 3 — 20975 29387 —4 E — 6 — 4 3 — — 249596 A 6 8 3 0 — 25176 — —6 A 6 1 2 1 3 — 32980 33161 —6 B 6 1 2 3 0 3 0 23092 — 230936 C — 1 0 1 5 — 23087 — —8 C — 1 2 1 5 — 23089 — —6 D — G1/4 2 0 2 0 23088 29179 229996 E — 1 0 — 4 6 — — 230908 E — 1 2 — 4 6 — — 23091

DThreadedconnection

CCementedconnection

E(Ermeto) screw

connection

12.97

Page 40: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

MB 1 02 20 / 11

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

Pump Fig. DN Conn. dim. di da L PVC PP St.steeltype D PVC 1.4571 1.4571DE / DX A 4 G 3/4 4 6 35 — 19480 — —20 A 6 G 3/4 6 12 55 — 19175 — —

B 6 G 3/4 6 12 30 — 23342 — —B1 6 d 20 6 12 — 30 — — 23426C 6 G 3/4 6 10 15 — 25167 — —C 8 G 3/4 — 12 15 — 27518 — —C 10 G 3/4 — 16 17 — 25625 —D 6 G 3/4 6 G 1/4 20 — 25165 — —D1 6 d 20 6 G 1/4 --- 20 — — 82105

DE / DX B 10 G 1 1/4 9 15 41 41 25921 — 2592540 - 100 B 15 G 1 1/4 16 24 50 50 25936 — 25935

C 10 G 1 1/4 — 16 22 — 27672 — —C 15 G 1 1/4 — 20 22 — 25937 — —C 20 G 1 1/4 — 25 22 — 33318 — —D 10 G 1 1/4 — G 3/8 22 22 25930 33797 27.037D 15 G 1 1/4 — G 1/2 22 22 25943 33798 25944D 20 G 1 1/4 — G 3/4 — 22 — — 27689F 15 G 1 1/4 — 15 47 53 25956 — 25957

ATubing

connection

B B1Hose liner

D D1

Threaded connection

F

Flanged connection

CCementedconnection

5 Connections DE/DX 20...100

Page 41: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

MB 1 02 20 / 12

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

Installation example

* In the case of effervescent media, it is recommended toprovide the pump with a positive suction head.

Legend

1 MAGDOS metering pump MB 1 02 202 Suction line MB 1 22 003 Electric agitator MB 1 36 004 Tank MB 1 20 015 Relief valve MB 1 25 016 Diaphragm shutoff valve MB 1 24 057 Injection nozzle MB 1 23 018 Pulsation dampener MB 1 27 019 Switch box

1 0 Water meter MB 1 37 011 1 Back pressure valve MB 1 25 011 2 Diaphragm leak detector

"Leak-Check" MB 1 31 01

Example of an orderA solenoid metering pump controllable by water metercontacts is required for metering 0.4 ml phosphate perstroke against 8 bar. For remote monitoring from acentral control station, a warning alarm relay is to beprovided.

Pump selectiona ) Based on the flow rate of 0.4 ml/stroke, the

MAGDOS 4 is determined according to theperformance curve (MB 1 02 20/6). Because of therequired warning alarm relay, the control unit ofpump type DE4S, Part No. 33942, must be chosenfrom table 2.

b ) Select drive Part No. 32720 from table 1.c ) Part No. 23.809 is chosen as metering head (PVC

is compatible with phosphate).d ) For the suction and discharge valves, select Part

No. 20.890 and No. 20.891 (PVC and Viton areresistant).

e ) See table 5 for suction connection Part No. 20975for ø 4/6 tubing and discharge connection Part No.32980 for ø 6/12 tubing.

f) The suction line, preferable with level control, canbe found in MB 1 22 01.

10

7

11

4

3

122

918

5

1

2

3

4

4

5

5

Place the order as follows:MAGDOS DE 4 S consisting of:

Drive 32720

Control unit 33942

PVC metering head 23809

PVC suction valve 20890

PVC discharge valve 20891

Suction connection 4/6 20975

Discharge connection 6/12 32980

6

Page 42: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 1

View of key components

Consisting of: Pump Head Parttype material Sealings Number

01 PVC, PMMA Viton 33066PVC, PMMA PTFE 33067

Diaphragm 03 PVC,1.4571 Viton 29742O-r ings PVDF Viton 33853Gaskets PVC, 1.4571 PTFE 29758Valve balls PVDF PTFE 33858Valve seats 07 ... 4 P V C Viton 29746

PVDF Viton 33854P V C PTFE 29759PVDF PTFE 33859P V C EPDM 336961.4571 PTFE 29747

8 P V C Viton 29748PVDF Viton 33855P V C PTFE 29790PVDF PTFE 33860P V C EPDM 336971.4571 PTFE 29749

12 P V C Viton 29750PVDF Viton 33856P V C PTFE 29791PVDF PTFE 33861P V C EPDM 336981.4571 PTFE 29751

20 P V C Hypalon 27802P V C Viton 278031.4571 A F 27808

40 P P Hypalon 27804P P Viton 278051.4571 A F 27810

100 P P Hypalon 27806P P Viton 278071.4571 A F 27812

ET 1 02 20 / 4, 5, 6

ET 1 02 20 / 8, 9, 10, 11

ET 1 02 20 / 12,13,14

ET 1 02 20 / 7

ET 1 02 20 / 12,13,14

ET 1 02 20 / 8, 9, 10, 11

ET 1 02 20 / 2, 3

Spare parts kit

Page 43: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 2

I tem Description Qty Pump type

0 1 0 3 0 7 2 4 8 1 21 Housing 1 27078

2 Diaphragm rod 1 32713

3 Pressure spring 1 293824 Screw 4 83613

5 Snap ring 1 84154

6 Washer 1 841447 Cable gland nut P G 7 1 78786

8 Grommet P G 7 1 78787

9 Solenoid 230 V ~ 1 32730 32714 32715115 V ~ 1 32746 32748

1 0 Solenoid retaining screw 2 83514

1 1 Diaphragm insert 1 32958 28849 28850 28851 288521 2 Diaphragm 1 81683 81424 81463 81464

1 3 Support plate (*spacer) 1 — 29312 23892 *33897

1 4 Deflector plate 1 220661 5 Cover plate 1 33164

1 6 Damping ring 1 81680 78509

Drive units MAGDOS DE / DX 01 ...12

Page 44: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 3

Drive units MAGDOS DE / DX 20 ... 100

I tem Description Qty Pump type

2 0 4 0 1001 Diaphragm flange 1 23913 24024 24041

2 Housing 1 21593

3 Solenoid assembly 230 V 1 79020Solenoid assembly 115 V 1 79021

4 Sponge rubber cord 1 97593

5 Screw 3 831056 Socket-head cap screw 4 83668

7 Washer 3 84160

8 Toothed washer 1 841459 Dummy plug 2 78788

1 0 Foam rubber 3 81727

1 1 Armature 1 217381 2 Buffer ring 1 78511

1 3 Pressure spring 1 19617

1 4 Diaphragm rod 1 19780 21599 216001 5 Deflector plate 1 22056 22057 22058

1 6 Support plate 1 28977 — —

1 7 Diaphragm 1 81465 81466 814671 8 Leakage pipe 1 25174 25190

1 9 O-r ing 1 80005 80058

Page 45: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 4

Control unit for DE / DX 01...12

Control unit for DE / DX 20...100

* only with 115 V version

* only with 115 V version

(24)*(25)*

Page 46: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 5

Part No.Item Description: D E DE...S DE...D DE...SD D X DX...S DX...D DX...SD

1 Housing for version 230 V 33873 33874 33875 33876115 V 34130 34131 34132 34133

2 Housing seal 817103 Screw 834094 Electronics 230 V ~ 78682 78683 78682 78683 78684

115 V ~ 78663 786645 Display board — 78782 — 787826 Stroke adjustment 01, 03 34045

07, 2 340464 34047

8, 12 340487 O-ring 800728 Screw 837469 Adjustment knob 32661

10 Adjustment knob 3387711 Control cover 2224712 Locking screw 2158713 Screw 8354314 Screw 8365315 Power supply cable 230 V ~ 78997

115 V ~ 7901316 Cable gland nut P G 7 7878617 Grommet P G 7 7878718 Warning relay cable 230 V — 78800 — 78800 — 78800 — 78800

115 V — 78980 — 78980 — 78980 — 78980

19 Jack socket 3387820 Cover plug 230 V 7878821 Insulation adpater plug 7891622 Dummy plug 2911523 External control cable 230 V 78947

connection socket 115 V 3331724 Gland nut (115V) P G 9 7890425 Gland nut (115V) P G 7 — 78615 — 78615 — 78615 — 78615

26 Calibration table 01 —03 3386707 33868

2 338694 338708 33871

12 3387227 Display film — 78665 — 7866528 Cable with plug for

external control 115 V 32916

Control unit DE / DX 01...12

Page 47: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 6

Part No. Item Description: D E DE...S DE...D DE...SD D X DX...S DX...D DX...SD

1 Housing for version 230 V 33873 33874 33875 33876115 V 34130 34131 34132 34133

2 Housing seal 817103 Screw 831874 Electronics 230 V ~ 79016 79017

115 V ~ 79018 790195 Display board — 78782 — 787826 Stroke adjustment 343517 O-ring 800728 Screw 837469 Adjustment knob, stroke length 32661

10 Adjustment knob, internal - external 3387711 Control cover 2224712 Locking screw 2158713 Screw 8354314 Screw 8365315 Power supply cable 230 V ~ 78997

115 V ~ 7901316 Cable gland nut P G 7 7878617 Grommet P G 7 7878718 Warning relay cable 230 V — 78800 — 78800 — 78800 — 78800

115 V — 78980 — 78980 — 78980 — 78980

19 Jack socket 3387820 Cover plug for version 230 V 7878821 Insulation adapter plug 7891622 Dummy plug 2911523 Chinch plug 230 V 33879

3-pole connection socket 115 V 3331724 Gland nut (115V) P G 9 7890425 Gland nut (115V) P G 7 — 78615 — 78615 — 78615 — 7861526 Calibration table 20 34348

40 34349100 34350

27 Display film — 78665 — 7866528 Dummy plug 2508429 Spacer 2159430 Sponge rubber cord 9711331 Cable clamping ring 8418832 Foam rubber — 81727 — 81727

33 Socket-head cap screw 8329234 Washer 8402135 Toothed washer 8414536 Cable with plug for for 230 V 25096

external control for 115 V 32916

Control unit DE / DX 20...100

Page 48: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 7

Metering heads

Head material:Item Description: Q ty PMMA P V C PVDF 1.4571 P P

1 Diaphragm housing 01 1 32960 32919 — — —03, 07 1 — 25960 1 ) 28114 22527 —

2, 4 1 — 21603 28116 21611 —8 1 — 21222 28118 21612 —

12 1 — 22399 28689 21613 —20 1 — 18113 — 23912 —40 1 — — — 22329 22044

100 1 — — — 22394 220462 Socket-head cap screw 01...12 4 83551 83409 83409 83622 —3 Hex. head screw 20 4 — 83110 — 83110 —

40, 100 4 — — — 83685 834954 Washer 01 4 84143 — — — —

20 4 — 84160 — 84160 —40, 100 4 — — — 84174 84174

5 Pressure plate 40, 100 1 — — — — 184536 Venting screw 03, 07 1 — 32142 — — —7 Valve ball 03, 07 1 — 29778 — — —8 Nut 03, 07 1 — 32143 — — —9 Pipe union 03, 07 1 — 32845 — — —8 O-ring 2 ) 2 80618 80618 — — —

1) only available as assembly ( Part No. 25188) 2) Only for Magdos 01

Magdos 01, PMMA Magdos 01 , PVC Magdos 03 and 07, PVCMagdos 2 . . .12 , PVC including automaticMagdos 03 . . .8 , PVDF head ventingMagdos 03 . . .12 , 1.4571

Magdos 12, PVDF Magdos 20 . . . 100

Page 49: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 8

Item Description Part No. Material P V C PVDF 1.4571No.1 Valve body 20845 P V C 1 — —

Valve body 28108 PVDF — 1 —Valve body 19289 1.4571 — — 1

2 Ball guide 29446 P V C 2 — —Ball guide 29901 PVDF — 2 —Ball guide 28460 1.4571 — — 2

3 Valve ball 81550 Ceramic 2 2 24 Valve seat 81549 Ceramic 2 2 25 Gasket 81371 Viton 1 — 1

Gasket 81580 PTFE — 1 —6 O-ring 81384 Viton 1 1 17 Cover plug 19299 P V C 1 — —

Cover plug 28110 PVDF — 1 —Cover plug 24031 1.4571 — — 1

8 Gasket 81551 Viton 1 1 19 O-ring 80618 Viton 2 2 2

Suction valve assembly 29434 33700 28459Discharge valve assembly 29435 33701 28461

DN 3 valves for MAGDOS 01 and 03 l/h

Suction valve Discharge valve

Page 50: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 9

DN 4 valves for MAGDOS 07 . . . 12 l/h

Double-bal l valves Spring- loaded single-bal l valves

Item Description Part No. Material Double-ball valve Spring-loaded valveNo. P V C PVDF 1.4571 P V C PVDF 1.45711 Valve body 20845 P V C 1 — — 1 — —

Valve body 28108 PVDF — 1 — — 1 —Valve body 19289 1.4571 — — 1 — — 1

2 Ball guide 19294 P V C 2 — — — — —Ball guide 28109 PVDF — 2 — — — —Ball guide 19293 1.4571 — — 2 — — —Ball guide 24066 P V C — — — 1 — —Ball guide 29386 PVDF — — — — 1 —Ball guide 24067 1.4571 — — — — — 1

3 Valve ball 29778 Glass 2 — — 1 — —Valve ball 18044 1.4401 — — 2 — — 1Valve ball 25247 PTFE — 2 — — 1 —

4 Valve seat 81460 PVDF 2 2 2 1 1 15 Gasket 81371 Viton 1 — — 1 1 —

Gasket 81677 PTFE — — 1 — — 1Gasket 81138 Viton — 1 — — — —

6 O-ring 81384 Viton 1 1 — 1 1 —O-ring 80617 PTFE — — 1 — — 1

7 Cover plug 19299 P V C 1 — — 1 — —Cover plug 28110 PVDF — 1 — — 1 —Cover plug 24031 1.4571 — — 1 — — 1

8 Valve spring 25081 Hastelloy — — — 1 1 19 O-ring 80013 Viton 2 2 — 1 1 —

O-ring 80627 PTFE — — 2 — — 110 Gasket 81526 Viton 1 1 — 1 1 —

Gasket 81585 PTFE — — 1 — — 1Suction valve assembly 20890 33703 24029 25087 34370 25089Discharge valve assembly 20891 33704 24030 25088 34371 25090

Discharge valve Discharge valveSuction valve Suction valve

1.98

Page 51: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 10

DN 6 valves for MAGDOS DE / DX 20

PVC version Stainless steel version

Item Description Material Part Double-ball valve Spring-loaded valveNo. Suction valve Discharge valve Suction valve Discharge valve

PVC 1.4571 PVC 1.4571 PVC 1.4571 PVC 1.4571

Sealing material: H=Hypalon, V=Viton, AF=asbestos-free

1 Valve housing PVC 18189 1 1 — 1 1 — 1 1 — 1 1 —1.4571 19601 — — 1 — — 1 — — 1 — — 1

2 Ball guide PVC 82405 2 2 — 2 2 — — — — — — —1.4581 82102 — — 2 — — 2 — — — — — —PVC 23412 — — — — — — 1 1 — 1 1 —1.4571 25169 — — — — — — — — 1 — — 1

3 * Valve ball Ceramic 10017 2 2 — 2 2 — 1 1 — 1 1 —1.4401 10136 — — 2 — — 2 — — 1 — — 1

4 * Valve seat PVC 82406 2 2 — 2 2 — 1 1 — 1 1 —1.4571 82103 — — 2 — — 2 — — 1 — — 1

5 * Gasket Hypalon 81037 2 — — 2 — — 1 — — 1 — —Viton 81138 — 2 — — 2 — — 1 — — 1 —AF 81625 — — 3 — — 3 — — 2 — — 2

6 * Gasket Hypalon 81033 1 — — 1 — — 1 — — 1 — —Viton 81285 — 1 — — 1 — — 1 — — 1 —

7 * Gasket Hypalon 81041 1 — — 1 — — 1 — — 1 — —Viton 81141 — 1 — — 1 — — 1 — — 1 —

8 * Valve spring Hastelloy 25082 — — — — — — 1 1 1 1 1 1

1818

7

1818

5

2696

7

1818

8

1818

6

2516

1

2516

2

2877

5

2751

6

2751

7

2877

6H V AF H V AF H V AF H V AF

2696

8

* Recommended spare parts included in spare parts kit on ET 1 02 20 / 1.

Double-ball valves

Suction valve Discharge valve Suction valve Discharge valve

Spring-loaded valves

Suction valve Discharge valve Suction valve Discharge valve

5.99

Page 52: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 11

DN 10 valves for MAGDOS DE/DX 40 and 100

2684

1

2684

2

2969

4

2735

6

2735

7

2684

5

2570

7

2969

6

2735

3

2735

4

2969

7

H V AF H V AF H V AF H V AF

2969

5

Item Description Material Part Double-ball valve Spring-loaded valveNo. Suction valve Discharge valve Suction valve Discharge valve

PP 1.4571 PP 1.4571 PP 1.4571 PP 1.4571

Sealing material: H=Hypalon, V=Viton, AF=asbestos free

1 Valve housing PP 32453 1 1 — 1 1 — 1 1 — 1 1 —1.4571 32449 — — 1 — — 1 — — 1 — — 1

2 Ball guide PP 34142 2 2 — 2 2 — — — — — — —1.4581 82112 — — 2 — — 2 — — — — — —PP 22882 — — — — — — 1 1 — 1 1 —1.4571 22881 — — — — — — — — 1 — — 1

3 * Valve ball Glass 82457 2 2 — 2 2 — 1 1 — 1 1 —1.4401 82114 — — 2 — — 2 — — 1 — — 1

4 * Valve seat PP 82456 2 2 — 2 2 — 1 1 — 1 1 —1.4571 82113 — — 2 — — 2 — — 1 — — 1

5 * Gasket Hypalon 31035 1 — — 1 — — 1 — — 1 — —Viton 81198 — 1 — — 1 — — 1 — — 1 —AF 81629 — — 1 — — 1 — — 1 — — 1

6 * Gasket Hypalon 81238 2 — — 2 — — 1 — — 1 — —Viton 81276 — 2 — — 2 — — 1 — — 1 —AF 81627 — — 3 — — 3 — — 2 — — 2

7 * Gasket Hypalon 81239 1 — — 1 — — 1 — — 1 — —Viton 81277 — 1 — — 1 — — 1 — — 1 —AF 81628 — — 1 — — 1 — — 1 — — 1

8 * Valve spring Hastelloy 32577 — — — — — — 1 1 1 1 1 1

* Recommended spare parts included in spare parts kit on ET 1 02 02 / 1.

PVC version Stainless steel version

Suction valve Discharge valve Suction valve Discharge valve

Page 53: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 12

2

231

1

34

3

2

1

2

1

2

1

1

2

Conn. Assembly Spare partsType Material Size Part No. Item description Part No.

A P V C 4/6 20975 1 Union nut 881162 Connection 880123 Clamping ring 880034 Union nut 88004

5/8 21851 1 Union nut 820872 Connection 218524 Union nut 19397

6/8 25176 1 Union nut 820872 Connection 313704 Union nut 19397

6/12 32980 1 Union nut 881162 Connection 325723 Clamping ring 32571

PVDF 4/6 29387 1 Union nut 281202 Connection 880283 Clamping ring 880034 Union nut 88004

6/12 33161 1 Union nut 881172 Connection 325723 Clamping ring 32571

B P V C 5/8 28106 1 Union nut 820872.1 Hose connection 182663 Hose clamp 82398

2.2 Cem. conn. part 820131.4571 6/12 23093 1 Union nut 19303

2 Hose connection 180453 Hose clamp 82398

P V C 23092 1 Union nut 820872 Hose connection 180423 Hose clamp 82398

C P V C 10 23087 1 Union nut 820872 Cemented conn. 82014

12 23089 1 Union nut 820872 Cemented conn. 82013

D P V C G 1/4 23088 1 Union nut 820872 Threaded conn. 82185

PVDF 29179 1 Union nut 281202 Threaded conn. 28292

1.4571 22999 1 Union nut 193032 Threaded conn. 82186

E 1.4571 6 24959 1 Union nut 880342 Clamping ring 88035

8 29371 1 Union nut 880362 Clamping ring 88037

10 23090 1 Union nut 880382 Clamping ring 88039

12 23091 1 Union nut 880402 Clamping ring 88041

Connections for DE / DX 01...12

Page 54: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 13

Material Size Conn. Assembly Item Spare partsType Part No. description Part No.A PVC 6/8 28159 1 Union nut 82156

2 Connection 313704 Union nut 19397

6/12 19175 1 Union nut 821562 Connection 180943 Clamping ring 101784 Union nut 82139

B PVC 6/12 23342 1 Union nut 821562 Hose connection 180423 Hose clamp 82398

B1 1.4571 6/12 23426 1 Hose liner 182682 Hose clamp 82398

C PVC 10 25167 1 Union nut 821562 Cem. connection 82014

12 27518 1 Union nut 821562 Cem. connection 82013

16 25625 1 Union nut 236852 Flange bushing 22508

D PVC G 1/4 25165 1 Union nut 821562 Threaded conn. 82185

D1 1.4571 G 1/4 82105 1 Flange bushing 82105

Connections for DE / DX 20

Page 55: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

DE

/ D

X

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

ET 1 02 20 / 14

Connections for DE / DX 40 and 100

Conn. Material Size Conn. Assbly Item Spare partstype Part No. description Part No.

B PVC ø 9/15 25921 1 Union nut 822132 Clamping conn. 259203 Hose clamp 82398

ø 16/26 25936 1 Union nut 822132 Hose connection 259343 Hose clamp 82413

1.4571 ø 9/15 25925 1 Union nut 295182 Hose connection 259283 Hose clamp 82398

ø 16/26 25935 1 Union nut 295182 Hose connection 259333 Hose clamp 82413

C PVC ø 16 27672 1 Union nut 822132 Cemented conn. 27846

ø 20 25937 1 Union nut 822132 Cemented conn. 25931

ø 25 33318 1 Union nut 822132 Cemented conn. 82952

D PVC G 1/2 25943 1 Union nut 822132 Threaded conn. 25940

1.4571 G 1/2 25944 1 Union nut 295182 Threaded conn. 25938

G 3/4 27689 1 Union nut 295182 Threaded conn. 27690

F PVC DN 15 25956 1 Union nut 822132 Flanged conn. 321783 Flange 14264

1.4571 DN 15 25957 1 Union nut 295182 Flanged conn. 213093 Flange 142004 Threaded conn. 25938

Page 56: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 1

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

Operating and Maintenance Instructions

appear which are unreasonably high even if themetering pump fails. We recommend installingleakage probes and containment tanks.Metering pumps are produced according to highestquality standards and have a long service life.Nevertheless some parts are subject to wear (e.gdiaphragm, valve seats, valve balls). To ensure longoperating life, visual checks are required regularly.Operating and maintenance personnel must beable to access the pump easily. Periodicmaintenance protects the metering pump againstshutdowns.To increase the metering accuracy and reliability,we recommend using additional fittings. Theseinclude backpressure valves, relief valves, leakageprobes, and chemical low level indicators, as shownin figures 1 to 3.Always use appropriate tools for the installation ofplastic connecting parts. In order to avoid damage,never apply excessive force; plastic parts (especiallyPVC parts) can be screwed and unscrewed moreeasily if the thread is lubricated with vaseline orsilicone grease before.Note: For this purpose, the compatibility with thechemical to be metered must be checked.MAGDOS metering pumps with integrated levelcontrol function are equipped with a short-circuitjack plug which must be removed before connectinga level control by means of a jack plug. To keep theprotection class, screw a PG plastic sleeve on thejack plug. The required PG sleeve is part of the levelcontrol (also in combination with a suction line).Mounting the metering pump directly on the watermeter may result in noise level amplification. In thiscase, it is recommended to mount the pump onseparate wall brackets which, for the same reason,should be fixed to outer walls instead of interior wallswith adjacent occupied rooms. It is also possible tomount the pump directly on the metering supplytank.Ambient temperatures exceeding 40°C are notpermitted. Radiant heat of apparatus and heatexchangers must be kept in limits allowing the pumpto sufficiently dissipate its own heat. Exposure todirect sunlight should be avoided especially formetering pumps with plastic housings because theblack plastic material can be damaged. If the pumpis installed outside, provide an enclosure to protectit against weather.Wiring of the MAGDOS metering pump must becarried out by a specialist according to the localregulations. Normally the MAGDOS is connectedwith a safety plug. The electrical data for all MAGDOSdata is listed in Table 14 "Technical data".Note: The MAGDOS metering pumps are not suitedto be used in explosive environments.

Keep the operating instructions of the meteringpump and the accessories readily accessible.

List of contents1. General2. Scope of delivery3. Installation4. Injection fitting installation5. Safety instructions6. Installation example7. Startup8. Replacing the diaphragm9. Drive solenoids

10. Correction of stroke length setting11. Control panel12. Circuit diagrams13. Functional overview14. Technical data15. Troubleshooting

1. GeneralSolenoid metering pumps can be used in manyapplications. It is a particular advantage that theycan be controlled proportionally to water metercontacts. They are also suited to be used asregulating units in automatic control systems. Seetable 13 for various control types and monitoringfacilities.

2. Scope of deliveryBe careful when unpacking the metering pump andpossible accessories in order not to miss smallparts. Compare the scope of delivery to the deliverynote. If there are any discrepancies, try to find outthe reason.

3. InstallationFor selection of a pump during construction of aplant as well as for installation and operation, thelocal rules must be observed. This applies to theselection of suitable pump materials, the handling ofthe chemicals and the electrical installation. At thesame time the technical data of the metering pumpaccording to table 12 must be considered, and theplant must be designed correspondingly (e.g.pressure loss in lines depending on nominal diameterand length).Both, the designer and the user are responsible tomake sure that the whole plant including the meteringpump is constructed so that neither plant equipmentnor buildings are severely damaged in the case ofchemical leakage due to the failure of wear parts(e.g. diaphragm rupture) or burst tubing. Whenconstructing chemical plants, the installation mustbe carried out so that no consequential damages

Page 57: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 2

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

Do not lay signal cables of water meters or0(4)...20mA controls parallel to high-voltage currentor power supply lines. Supply and signal lines mustbe laid in separate channels. In the case of junctions,a 90° angle is required. If the water meter controlcable is more than 2 meters long, it must be shielded.To avoid incorrect metering after the process isfinished, provide an electric and hydraulic interlockingsystem.

4. Injection fitting assemblyInjection nozzles prevent the liquid from returning tothe pump by using either a spring-loaded ball valveor a hose valve. We recommend vertical injectionfrom bottom to top to allow air to escape therebyavoiding chemical precipitation. Experience withthe particular metering chemical and all appropriatecharacteristics must be taken into account.

5. Safety instructions⇒ When working on chemical equipment, observethe local safety rules (e.g. wear personal protectiveclothes).⇒ Before working on the metering pump and plant,disconnect it from the main power supply and secureit against reconnection. Before the voltage supply isswitched on again, the metering lines must beconnected so that chemical left in the metering headcannot spurt out.⇒ The metering head of the pump as well asconnections and lines in the plant may be underpressure. Working on the metering plant requiresspecial safety precautions and may only be carriedout by instructed technical personnel.⇒ Before startup, all screwed connections must bechecked for correct tightness and, if necessary,must be tightened up using appropriate tools.⇒ If connections at the metering head areunscrewed during operation for venting or otherreasons, leaking chemical must be removedcompletely. This is the only way to avoid the dangerof physical injury and corrosion at the meteringpump. Leaking chemical may also destroy thediaphragm at its mounting points.⇒ When changing the chemical, check whether thematerials used for the metering pump and the otherplant parts are chemically resistant.If there is the danger of a chemical reaction betweendifferent media, a thorough cleaning first ismandatory.⇒ After adjustment work at the control panel of theMAGDOS, the control cover must be closed again(the cover is not available for all MAGDOS types).Otherwise protection class IP 65 cannot beguaranteed.⇒ After changing the electrical connections, e.g.removing the level control, the PG cable gland nutmust be tightened in order to ensure the protectionclass of the pump.

Injection fitting

Page 58: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 3

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

6. Installation example

Fig.1

MAGDOS DE/DX 40 and DE/DX 100 can only bemounted parallel to the wall.

Fig. 3

Fig. 2

1 MAGDOS MB 1 02 002 Suction line with integrated

level control MB 1 22 013 Hand mixer MB 1 36 024 Chemical tank MB 1 20 015 Leakage probe for monitoring

the diaphragm MB 1 31 016 Relief/safety valve MB 1 25 017 Shutoff valve for isolating the

pump from the plant MB 1 24 018 Back pressure valve for max.

metering accuracy MB 1 25 019 Injection nozzle with non-return

va lve MB 1 23 0110 Venting as separate part or MB 1 33 02

integrated in the metering head MB 1 33 0311 Water meter with contact unit MB 1 37 0112 Pulsation dampener for reducing

pressure peaks and smoothingthe flow MB 1 27 01

13 Separation chamberis recommended if the mediacould damage the pump in thecase of a diaphragm failure MB 1 28 01ATTENTION!Leakage must be dischargedinto a collection funnel usinga short incl ining drain pipe(and can then be returned tothe chemical tank).The outlet of the drain pipemust be visible in order toactual ly see the leakage.

14 Priming aidThis equipment allows easystartup of small pumps in particular.The entrained gas serves as apulsation dampener. MB 1 33 01

15 Water meter spacer MB 1 37 01ATTENTION!The spacer is required toavoid that the drive solenoidaffects the water metercontact.

16 Wall bracket MB 1 32 0017 Tall or short adapter for tank

mounting

Page 59: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 4

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

8. Replacing the diaphragmThe diaphragm can be easily removed and replacedaccording to the exploded drawing. To facilitateremoval of the old diaphragm, first set the stroke to"0" while pump is running. If the diaphragm rod isturning it can be stopped by means of a locking pin(JESCO P/N 29379). The drilled hole in thediaphragm rod can be accessed through the drainagechannel.

Suction valve Drainage tubeMetering head Snap ring

Grease diaphragm rod with Molycote.

The deflector plate must rest in the diaphragm rodgroove. Ensure that it is not clamped between thediaphragm rod and the support plate. If the diaphragmis supplied with a support plate, clean or replace thelatter before mounting it.

9. Drive solenoidsDepending on the pump version, the solenoid designdiffers. The following table shows the coil resistanceat 20°C room temperature. With perfect coils, theresistance tolerance should not exceed +/-5%. If theresistance is substantially lower, there is a short inthe coil, if the resistance is indefinitely high, the coilis fused or the wire is broken.

7. Startup

ATTENTION!Adjust the stroke length only whi le pump isrunn ing.

1. For first startup, set pump to maximum strokefrequency or press start key and allow to prime. For this purpose, it is advisable to set thestroke to "10". If the pump doesn't prime, removedischarge valve and pour water or chemical (ifharmless!) into head. Mount the valve and allowto prime again (priming aid, item 14, fig. 2 isrecommended).

2. If a venting facility is integrated in the meteringhead or is available as separate unit, open it andwait until liquid escapes. Then close it again. Inthe case of effervescent liquids allow the liquidto escape permanently (approx. 1 drop for1...3 strokes).

3. When correct operation is achieved, set torequired output and lock adjusting knob. Referto the calibration table attached to the pump toget the stroke length setting for a selected output(ml/pulse). The back pressure influences aretaken into consideration in the table, andintermediate values must be interpolated.Depending on the installation and the chemicalsused, these values may differ and must bechecked under operating conditions.

Example:

Required metering capacity: 0.8 ml/pulse against8 bar.The table says H=9.9. Adjust knob "H" accordinglywhile the pump is running.

4. In the case of externally actuated pumps (e.g. bywater meters), set pump to "external". Initiatethe water flow by opening a water valve andcheck pump pulse rate.

5. The manufacturer of the metering equipment isnot responsible for damages due to excessive orlow flow rates resulting from faulty pump settingsor incorrect and insufficient installation ofperipheral fittings.

Washer

Return spring

Groove fordeflector plate

Discharge valve

Diaphragm Deflector plate

Support plate if required

Drilled holeforlocking pin

Page 60: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 5

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

3. Attach knob so that the indicator is pointing to "0"and, with the knob tightly held, fasten screw.

4. Run pump according to a setting of the outputtable. If there is a major discrepancy, correct theknob position.

Test check for drive solenoids

SolenoidMark

a

b

c

Protective conductor

The resistance between a-c and b-c is infinite.

Resistance of cold coils (20 °C)

Solenoid in Resistance [Ω] +/- 5 %pump version between a-b at

230V~ 115V~ 24V =

E, EL, FL only EL, FLDE, DX0.1...2 113 30 1.9

E, EL, FL only EL, FLDE, DX4...12 91 30 1.9

DE, DX20...100 51 14 - -

10. Correction of stroke length settingTo avoid excessive metering, the metering line mustbe returned to the chemical tank during setting (ifnecessary).

1. Operate pump with automatic control (ifnecessary, by pressing the start key for FL).

2. Regardless of the indicator position, loosen thefastening screw and turn the stroke lengthadjustment knob counterclockwise until the pumpno longer delivers or, in the case of no-pressuredelivery, the flow rate has reached the minimum.If zero delivery could not be attained becausethe knob reached the stop position, remove theknob after loosening the fastening screw, turn itto the right and reattach it. Then turn again to theleft until the pump no longer delivers.

ToothingPhilipshead screw

Stroke lengthadjustment knob

Page 61: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 6

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

Calibration table

"Start" keyfor FL

Chemical low lightsignal for El and FL

Level probe forEL and FL

External controlconnection for FL

Warning alarmrelay cable forEL and FL

Power supply

Operating light

Stroke lengthadjustment

Locking screw

11.1 Control panel

E, EL and FL pumps

Page 62: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 7

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

11.2 Control panel

Magdos DE

Magdos DX

1

1 Power supply cable, 2 m, with plug

2 Cable for warning alarm relay, 1.5 m

3 3.5 mm jack for level probe connection;can be used by 2-pin plug for simple lowlevel indication or by 3-pin plug for low levelindication with alarm signal.

4 a Cable/connection socket for pulse input4 b Cable/connection socket for pulse and d.c.

signal input

5 Adjusting knob for metering capacity perstroke

6 Locking screw

7 Stroke frequency ajdustment withchangeover switch for external control

8 Digital display (optional)

9 a Red LED- blinks slowly in the case of alarm signaling

and lights permanently if the tank is empty.Pump is then stopped automatically.

9 b - like a, plus fast blinking if, in the case ofd.c. 4...20mA signal control, the inputsignal is less than 4mA (e.g. due to cablerupture).

- blinks slowly if selector switch (12) is setto "0" (pump is not metering).

10 Green LEDlights if power supply voltage is applied andblinks off during the metering stroke.

11 Calibration table

12 Selector switch for external control

Pulse 1:1

Pulse division 2 / 4 / 8 / 16 / 32 / 64

Pulse multiplication 2 / 4 / 8 / 16 / 32 / 64

Input signal 0...20mA or 4...20mA

Pump stop "0"

Page 63: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 8

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

12.2 Circuit diagram

EL and FL pumps 24V

12.1 Circuit diagram

E pumps

Power supply230V/50Hz or115V/60HzSolenoid

Solenoid

Level control

to warning alarm circuit board

Start key

Pulse signal input

red

brown

bro

wn

blue

red

white

Page 64: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 9

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

12.3 Circuit diagram

EL and FL pumps230V/50Hz and 115V/60Hz

Solenoid

Startkey

Soldering jumpers forstroke frequency:Only jumper maybe connected at atime!

one

Relay inversion:Remove jumper FSand connect jumperNFS.

Pulseinput

brown

white

red

red

NFS FS

Level control Powersupply

blac

kbr

own

blue

brown/black closed in the case of operation

red

red

gree

n/ye

llow

1002550

7.00

Page 65: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 10

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

12.4 Circuit diagram

DE / DX pumps230 V / 50 Hz

115 V / 60 HzRelay reversal: Open upper solder jumper,

close lower one.

Solenoid

Warning alarm:

Powersupply

Signalinput

Level control

green/yellow

whi

tere

dbl

ack

blac

kre

dbl

ue

blue

brow

n

Display

blue

red

blue

Solenoid

Display

Relay reversal: Open upper solder jumper,close lower one.

green/yellow

blue

bro

wn

blac

k Powersupply

Level control

Signal input

Warning alarm:

blue

red

blac

k

brownwhite

whitered

brown

black

brown/blue closedin the case of failurebrown/black closed during operation

red/white closedin the case of failurered/black closed during operation

Page 66: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 11

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

13. Functional overviewPump type

Features Magdosx = Standardo = Optional E E L F L D E DXVoltage 230 V~/50 Hz x x x x x

115 V~/60 Hz x x x x x24 V = x x

Internal control x x x xExternal contact x x xcontrol 0...20mA xby 4...20mA xPulse division/multiplication xLow level indication via LED x x x xAlarm via warning relay o oLevel control with alarm signal x xDigital display o o

E/EL/FL EL/FL DE/DX 01...12 DE/DX 20...100V 230~ 115~ 24 = 230~ 115~ 230~ 115~

Electrical connection Hz 50 60 — 50/60 50/60 50/60 50/60Power supply cable with plug m 2 2 2 2Power consumption W 30 30 30 30 33 70 66Max. stroke frequency min -1 100 100 100 70Current consumptionduring stroke A 2.3 3.6 12.6 2.3 3.6 4.1 7.4Fuse A T1.6 T3.15 T10 T0.8 T1.6 T2 T4Protection class IP 65 IP 65 IP 65 IP65Insulation class F F F FInput pulse durationto triggera stroke ms at least 30 at least 30 at least 30 at least 30Solenoid excitation timeper pulse ms 60 67 60 60 80 160 190Warning alarm Changeover V 250 AC,30 DC 250 AC,30 DCrelay with voltage A — — max. 2.5 max. 2.5changeover Changeover VA — — 500 500contact power W 100 100Voltage to low level probe V 9 AC 12 DC 5 DC 5 DCMin. conductivity requiredfor 2-bar probes µS 80 — — —Voltage to pulse control V 12 DC 12 DC 5 DC 5 DCInput impedence0(4)...20mA Ohm — — 150 150Weight, with plastic kg 2.7 2.7 2.9 12.5*metering head: SS kg 3.3 3.3 3.5 20*

* DE/DX 20 10.5 or 12 kg

In the case of 0(4)...20mA signal control (only MAGDOS DX) it is important that the signal line doesn't come intocontact with ground, if the signal source is not isolated (individual voltage separators upon request). The linearityof converting the signal into stroke frequency is +/- 3%.

14. Technical data

Page 67: MAGDOS E / EL / FL - lyma.com · the German Water and Gas Association and DIN ... 23809 28117 23812 4 ... MAGDOS E / EL / FL

MA

GD

OS

BW 1 02 98 / 12

Verbessernde Änderungen jederzeit ohne Vorankündigung vorbehalten.

JESCO DOSIERTECHNIK GmbH & Co. KG

NATURE OF PROBLEM POSSIBLE CAUSE RECOMMENDED ACTION

Pump not delivering or Valves leaking or blocked. Clean valves and bleed pump.output too low. See also start-up of pump

BW 1 02 98 / 4.Valves incorrectly installed. Reassemble valves.

Ensure that valve ballsare located above valveseats.

Suction valve or suction line Clean and seal suction line.leaking or blocked.Suction lift too high. Install pump at lower position.

Install pulsation dampener onsuction side.Install priming aid.

Viscositiy too high. Install spring-loaded valves.Enlarge line cross-section.Use special metering head.-----> Contact JESCO.

No stroke movement Pump set to zero stroke. Correctly adjust pump stroke.observed. Diaphragm return spring broken. Replace spring.

Fuse blown, LEDs off. Check power supply line,replace fuse (section 14).

Solenoid defective. Check coil resistance and isolation;replace solenoid, if required.

Red low liquid level Feed tank empty; level control or Fill tank or check suction line.indication LED on. dummy plug incorrectly inserted.Frequent diaphragm No support plate. Replace diaphragm with supportfailures. ATTENTION! plate. When replacing diaphragm,

Not al l diaphragms are supplied check if deflector plate or diaphragmwith support plate (acc. to spare rod have been corroded by pumpedparts l ist). See section 8, "Replacing fluid.the diaphragm", BW 1 02 98 / 4.Diaphragm was not screwed Screw in new diaphragm as far asinto the diaphragm rod as far stop. Support plate must then beas stop. clamped between diaphragm and

diaphragm rod.Back pressure to high Check system. Clean blocked(measured at discharge injection nozzle. Reduce pressureconnection of pump). peaks resulting from extremely

long tubes by installing pulsationdampeners.

Media sediment in Flush metering head.metering head.

Pump delivering too much. Pressure on suction side too high. Install back pressure valve(Pump siphoning). in discharge line.Stroke stop shifted. Readjust stop (see item 10).Stroke frequency too high. Reduce frequency.

If the problem cannot be corrected on the basis of the above data, return the pump to the factory or contact our After-Sales Service for further measures. Repairs will be carried out immediately.

15. Troubleshooting