maestro occupancy sensing switch...ms-ops6m2u-dv-xx smart adaptive enabled 15 ms-vps6m2u-dv-xx smart...

13
Maestro® Sensor 369741a 1 11.15.12 ® SPECIFICATION SUBMITTAL Page Job Name: Job Number: Model Numbers: Switch with Occupancy/Vacancy Sensor Maestro® Occupancy sensing switch To power the sensing circuit, occupancy sensing switches require a small flow of current when the load is in the OFF state. This can be accomplished by connecting the power supply return wire to ground or to neutral. Local codes in certain municipalities require that a neutral conductor be run to the switch box, regardless of construction. In one particular instance, installing occupancy sensors that use the ground wire to function is not permitted. The MS-OPS6M2U-DV and MS-VPS6M2U products allow the installer to configure the device to connect to either ground or neutral. To connect to ground, simply install the product in its "out-of-the box" condition. To connect to neutral, install the supplied white sleeve over the green wire. For more information about occupancy sensing switches and the National Electrical code, see: www.lutron.com/TechnicalDocumentLibrary/048469.pdf Features Passive infrared sensors with exclusive Lutron® XCTTM Technology for fine motion detection 180° sensor field-of-view Up to 30 ft x 30 ft (9 m x 9 m) [900 ft 2 (81 m 2 )] major motion coverage and 20 ft x 20 ft (6 m x 6 m) [400 ft 2 (36 m 2 )] minor motion coverage Occupancy version can be set to Auto-ON / Auto-OFF or Manual-ON / Auto-OFF Vacancy version available to meet CA Title 24 requirements Adjustable timeout (1, 5, 15, or 30 minutes) and high/low sensitivity adjustment Occupancy sensing switch loads: incandescent, halogen, ELV, MLV, CFL, LED, magnetic fluorescent, electronic fluorescent, and fan. Models available MS-OPS6M2U-DV MS-VPS6M2U-DV MS-OPS6M2U-DV MS-VPS6M2U-DV

Upload: others

Post on 27-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • Maestro® Sensor

    369741a 1 11.15.12

    ® SPECIF ICAT ION SUBMITTAL Page

    Job Name:

    Job Number:

    Model Numbers:

    Switch with Occupancy/ Vacancy Sensor

    Maestro® Occupancy sensing switchTo power the sensing circuit, occupancy sensing switches require a small flow of current when the load is in the OFF state. This can be accomplished by connecting the power supply return wire to ground or to neutral.Local codes in certain municipalities require that a neutral conductor be run to the switch box, regardless of construction. In one particular instance, installing occupancy sensors that use the ground wire to function is not permitted.The MS-OPS6M2U-DV and MS-VPS6M2U products allow the installer to configure the device to connect to either ground or neutral.

    • Toconnecttoground,simplyinstalltheproductinits"out-of-thebox"condition.• Toconnecttoneutral,installthesuppliedwhitesleeveoverthegreenwire.

    For more information about occupancy sensing switches and the National Electrical code, see:www.lutron.com/TechnicalDocumentLibrary/048469.pdf

    Features• PassiveinfraredsensorswithexclusiveLutron® XCTTM Technology for fine motion

    detection• 180°sensorfield-of-view• Upto30ftx30ft(9mx9m)[900ft2(81m2)]majormotioncoverageand

    20ftx20ft(6mx6m)[400ft2(36 m2)]minormotioncoverage• OccupancyversioncanbesettoAuto-ON/Auto-OFForManual-ON/Auto-OFF• VacancyversionavailabletomeetCATitle24requirements• Adjustabletimeout(1,5,15,or30minutes)andhigh/lowsensitivityadjustment• Occupancysensingswitchloads:incandescent,halogen,ELV,MLV,CFL,LED,magneticfluorescent,electronic

    fluorescent, and fan.

    Models availableMS-OPS6M2U-DV MS-VPS6M2U-DV

    MS-OPS6M2U-DVMS-VPS6M2U-DV

  • Maestro® Sensor

    369741a 2 11.15.12

    ® SPECIF ICAT ION SUBMITTAL Page

    Job Name:

    Job Number:

    Model Numbers:

    Switch with Occupancy/ Vacancy Sensor

    SpecificationsRegulatory Approvals

    • UL® Listed to U.S. and Canadian safety requirements.

    • NOMCertification(pending).

    Power• 120–277V~50/60Hz1

    Key Design Features• Alllightingloads.• Crush/tamperresistantlens.• Smartambientlightdetection.• Adaptiveswitchingalgorithmforextendedrelaylife.• XCTTM Technology for fine motion detection.

    Environment• Ambientoperatingtemperature:32°Fto104°F

    (0°Cto40°C),0%–90%humidity,non-condensing.Indoor use only.

    Warranty• 5-YearLimitedWarranty.ForadditionalWarranty

    information, please visit www.lutron.com/TechnicalDocumentLibrary/Sensor_Warranty.pdf

    Additional Information• ForMaestro® Occupancy sensing dimmer models,

    please see Lutron® P/N 369270.• ForotherMaestro® Occupancy sensing switch

    models, please see Lutron® P/N 369666.• ForusewithMA-AS,MSC-AS,MA-AS-277,or

    MSC-AS-277tocontroltheloadfrommorethantwolocations, please see Lutron® P/N 048435.

    • Formoreinformation,pleaseseewww.lutron.com/occvacsensors

    • LutronTechnicalHotline:1.800.523.9466.

    Advanced FeaturesSwitchingAdaptivezerocrossfeaturemaximizesrelaylifebyswitchingatthepointofminimumenergyontheACpowercurve.Activelyadaptstovariationsinrelaytiming.

    XCTTM TechnologyAdvancedsensingtechnologyforfinemotiondetection ensures that the lights stay on while the room is occupied, and that the sensor does not turn on falsely when there is no occupancy in the room. For more information, see www.lutron.com/TechnicalDocumentLibrary/white%20paper%20XCT%204-23-09%20B.pdf

    1 Maximum current ratings for individual models are provided in the Selection Matrixonpage4.

  • Maestro® Sensor

    369741a 3 11.15.12

    ® SPECIF ICAT ION SUBMITTAL Page

    Job Name:

    Job Number:

    Model Numbers:

    Switch with Occupancy/ Vacancy Sensor

    Custom SettingsAmbient Light Detection

    • Lightsturnononlyifnaturallightinroomislow.• Smart—Ambientlightthresholdadjustspreciselyto

    the user’s preference.Instructions: If switch turns on when there is enough natural light, or if switch does not turn on when there is not enough natural light, press thelargebuttonwithin5secondsofenteringtheroom.Overtime,thisinteraction will “teach” the switch your preferred setting.

    Sensor Operation• Occupancy/Vacancy:Auto-ON/Auto-OFFor

    Manual-ON/Auto-OFF• Vacancyonly:Manual-ON/Auto-OFFonly

    Timeout Options(SeeAdditional Featuresonpage4fordefaultsettings)

    • 1Minute• 5Minutes• 15Minutes• 30Minutes

    Sensitivity Options• Highsensitivity(default)• Lowsensitivity

    Auto-ON Options(MS-OPSonly)

    • Occupancy(default):Auto-ON/Auto-OFF• Vacancy*:Manual-ON/Auto-OFF• LowLight:Lightsturnononlyifneeded(ifambient

    lightisbelowthreshold) *Thereisa15-secondgraceperiodthatbeginswhenthelightsare

    automatically turned off, during which the lights will automatically turn back on in response to motion. This grace period is provided as a safety and convenience feature in the event that the lights turn off while the room is still occupied, so that the user does not need to manually turn thelightsbackon.After15seconds,thegraceperiodexpiresandthelights must be manually turned on.

    Manual Off-While-Occupied Options(MS-OPSonly—seeAdditional Featuresonpage4fordefaultsetting)

    • Enabled– WhentheOccupancysensingswitchismanually

    turned off, the Occupancy sensing switch will not turn the lights back on automatically while the room is occupied.

    – Oncetheroomisvacated,theAuto-ONfeaturereturns to normal operation after the timeout period has expired.

    – Thismaybethepreferenceinconferenceroomsor classrooms while viewing presentations. This feature requires motion to keep the lights off.

    • Disabled– WhentheOccupancysensingswitchismanually

    turnedoff,theAuto-ONfeaturewillreturntonormaloperationafter25seconds.

    – Thismaybethepreferenceiftheuseralwayswants the lights to turn on upon entering and the lights to turn off when the room is vacant.

  • Maestro® Sensor

    369741a 4 11.15.12

    ® SPECIF ICAT ION SUBMITTAL Page

    Job Name:

    Job Number:

    Model Numbers:

    Switch with Occupancy/ Vacancy Sensor

    Selection Matrix

    1XXinmodelnumberrepresentscolor/finishcode.

    2OccupancysensorscanbeconfiguredasAuto-ON/Auto-OFForManual-ON/Auto-OFF. VacancysensorsareconfiguredasManual-ON/Auto-OFFonly.

    3Standardmechanical3-wayswitchcannotbecombinedwithcompanionswitch.

    4CompanionswitchMA-AS,MSC-AS,MA-AS-277,orMSC-AS-277isrequiredformulti-locationinstallations(morethantwolocationscontrollingthesamelightingcircuit).Uptoninecompanionswitchesmaybeconnected.

    5Thegreenwirecanbeconnectedtogroundor,whencoveredbythewhitesleeve,canbeconnectedtoneutral(seeillustrationsonpage7).

    Crush/tamper-resistant lens

    Ambient light detection

    Switching

    XCTTM technology

    Manual off-while-occupied default setting

    Default timeout (minutes)

    Model Number1

    MS-OPS6M2U-DV-XX Smart Adaptive Enabled 15MS-VPS6M2U-DV-XX Smart Adaptive 15

    Additional Features

    1XXinmodelnumberrepresentscolor/finishcode.

    Vacancy only2 (Title 24 compliant)

    Single-pole onlySingle-pole / 3-way capability

    Works with standard mechanical 3-way switch3

    Works with companion switch3, 4

    All lighting loads (120 V~ only)

    Max current rating

    All lighting loads (120 – 277 V~ only)

    Fan (120 V~)

    Light + Fan (120 V~)

    Neutral or ground wire required for functionality5Off-state power

    Minimum load required

    Model Number1

    MS-OPS6M2U-DV-XX 6A 3A 3A MS-VPS6M2U-DV-XX 6A 3A 3A

  • Maestro® Sensor

    369741a 5 11.15.12

    ® SPECIF ICAT ION SUBMITTAL Page

    Job Name:

    Job Number:

    Model Numbers:

    Switch with Occupancy/ Vacancy Sensor

    5ft (1.5m)

    10ft (3m)

    15ft (4.5m)

    20ft (6m)

    25ft (7.5m)

    30ft (9m)

    Horizontal Beam Diagram

    5ft (1.5m)

    5ft (1.5m)

    0

    10ft (3m)

    10ft (3m)

    15ft (4.5m)

    15ft (4.5m)

    20ft (6m)

    20ft (6m)

    25ft (7.5m)

    25ft (7.5m)

    30ft (9m)

    30ft (9m)

    Vertical Beam Diagram

    4ft (1.2m)

    00 10ft (3m)

    15ft (4.5m)

    20ft (6m)

    25ft (7.5m)

    30ft (9m)

    NEMA WD7 Coverage

    5ft (1.5m)

    5ft (1.5m)

    0

    10ft (3m)

    10ft (3m)

    15ft (4.5m)

    15ft (4.5m)

    5ft (1.5m)

    Majormotioncoverage:900ft2(81m2)

    Minormotioncoverage:400ft2(36m2)

    Occupancy Sensing Switch Placement and Operation• TheabilityoftheOccupancysensingswitchtodetectmotionrequiresline-of-sightofroomoccupants.The

    Occupancy sensing switch must have an unobstructed view of the room.• HotobjectsandmovingaircurrentscanaffecttheperformanceoftheOccupancysensingswitch.• TheperformanceoftheOccupancysensingswitchdependsonatemperaturedifferentialbetweentheambient

    roomtemperatureandthatofroomoccupants.WarmerroomsmayreducetheabilityoftheOccupancysensingswitch to detect occupants.

    DefinitionsMajor motion: movement of a person entering or passing through an area.Minor motion:movementofapersonoccupyinganareaandengaginginsmallactivities(e.g.,reachingforatelephone,turningthepagesofabook,openingafilefolder,pickingupacoffeecup).

  • Maestro® Sensor

    369741a 6 11.15.12

    ® SPECIF ICAT ION SUBMITTAL Page

    Job Name:

    Job Number:

    Model Numbers:

    Switch with Occupancy/ Vacancy Sensor

    DimensionsMeasurementsshownas:in(mm).

    Front View Side View

    411⁄16(119)

    215⁄16(75)

    11⁄8(30)

    5/16(8)

    1/8(3)

    Mounting

    WallplateAdapter/Wallplate (soldseparately)

    Occupancy Sensing SwitchWallbox

    Mounting screws Adaptermountingscrews

    Operation

    MS-OPS6M2U-DVMS-VPS6M2U-DV

    Sensor Lens

    Sensor LED(behindlens) Pulses during configuration of custom settings and in the Test mode.

    TapswitchTapon/off

  • Maestro® Sensor

    369741a 7 11.15.12

    ® SPECIF ICAT ION SUBMITTAL Page

    Job Name:

    Job Number:

    Model Numbers:

    Switch with Occupancy/ Vacancy Sensor

    Slide white sleeve over green wire until flush with back cover.

    White(connectstoNeutral)

    Converting Ground Wire to Neutral WireThe green wire can be connected to ground or, when covered by the white sleeve, can be connected to neutral.

    Blue(3-way)

    Black(hot/switchedhot)

    Green(connectstoGround)

    Whitesleeve

    Bare: always connect to ground

  • Maestro® Sensor

    369741a 8 11.15.12

    ® SPECIF ICAT ION SUBMITTAL Page

    Job Name:

    Job Number:

    Model Numbers:

    Switch with Occupancy/ Vacancy Sensor

    Continued on next page...

    Wiring Diagrams: Single-Location InstallationsWiring Diagram 1: Connect occupancy sensing switch to groundSingle-Location Installation (120-277 V~)1, 2-OPS6M2U-DV 3, -VPS6M2U-DV 3

    120-277V~ 50/60Hz

    Green

    Ground

    Hot/Live

    Neutral

    Load

    Blue1

    Bare

    Black Black

    Occupancy sensing switch

    Wiring Diagram 2: Connect occupancy sensing switch to neutralSingle-Location Installation (120-277 V~)1, 2-OPS6M2U-DV4, -VPS6M2U-DV4

    Occupancy sensing switch

    120-277V~ 50/60Hz White

    Ground

    Hot/Live

    Neutral

    Load

    Blue1

    Bare

    Black Black

    1 Whenusingcontrolsinsinglelocationinstallations,tightentheblueterminalorcapbluewire.DoNOTconnecttheblueterminal/wiretoanyotherwireortoground.2 Fanloadappliesto120V~only(notforusewith277V~).3 Green wire is connected to ground.4 Wirecoveredbywhitesleeveisconnectedtoneutral.

  • Maestro® Sensor

    369741a 9 11.15.12

    ® SPECIF ICAT ION SUBMITTAL Page

    Job Name:

    Job Number:

    Model Numbers:

    Switch with Occupancy/ Vacancy Sensor

    1 Only one Occupancy sensing switch can be used per multi-location circuit.2 Asinglestandardmechanical3-wayswitchorupto9companionswitchesmaybeconnectedtomostOccupancysensingswitches.Standardmechanical3-way

    switchcannotbecombinedwithcompanionswitch.Totalblueterminalwirelengthmaybeupto150 ft(46 m).3 Fanloadappliesto120V~only(notforusewith277V~).4 Green wire is connected to ground.

    Wiring Diagram 3: Connect occupancy sensing switch to ground3-way Installation with Standard Mechanical 3-way Switch (120-277 V~)1, 2, 3-OPS6M2U-DV 4, -VPS6M2U-DV 4

    Black

    Blue

    Green

    Ground

    Occupancy sensing switch

    Green screw

    Ground

    120-277V~ 50/60Hz

    Hot/Live

    Neutral

    Load

    Standard mechanical 3-way

    switch

    BlackJumper wire

    BareDifferent color screw (Common)

    OR

    Black

    Blue

    Ground

    Occupancy sensing switch

    Green

    Ground

    120V~ 50/60Hz

    Hot/Live

    Neutral

    Load

    Standard mechanical 3-way

    switch

    BlackJumper wire

    Bare Different color screw (Common)Green screw

    Wiring Diagrams: 3-way Installations with Standard Mechanical 3-way Switch

    Continued on next page...

  • Maestro® Sensor

    369741a 10 11.15.12

    ® SPECIF ICAT ION SUBMITTAL Page

    Job Name:

    Job Number:

    Model Numbers:

    Switch with Occupancy/ Vacancy Sensor

    Continued on next page...

    Wiring Diagram 4: Connect occupancy sensing switch to neutral3-way Installation with Standard Mechanical 3-way Switch (120-277 V~)1, 2, 3-OPS6M2U-DV4, -VPS6M2U-DV4

    Black

    Blue

    WhiteGround

    Occupancy sensing switch

    Green screw

    Ground

    120-277V~ 50/60Hz

    Hot/Live

    Neutral

    Load

    Standard mechanical 3-way

    switch

    BlackJumper wire

    BareDifferent color screw (Common)

    OR

    Black

    Blue

    Ground

    Occupancy sensing switch

    WhiteGround

    120V~ 50/60Hz

    Hot/Live

    Neutral

    Load

    Standard mechanical 3-way

    switch

    BlackJumper wire

    Bare Different color screw (Common)Green screw

    Wiring Diagrams: 3-way Installations with Standard Mechanical 3-way Switch (continued)

    1 Only one Occupancy sensing switch can be used per multi-location circuit.2 Asinglestandardmechanical3-wayswitchorupto9companionswitchesmaybeconnectedtomostOccupancysensingswitches.Standardmechanical3-way

    switchcannotbecombinedwithcompanionswitch.Totalblueterminalwirelengthmaybeupto150 ft(46 m).3 Fanloadappliesto120V~only(notforusewith277V~).4 Wirecoveredbywhitesleeveisconnectedtoneutral.

  • Maestro® Sensor

    369741a 11 11.15.12

    ® SPECIF ICAT ION SUBMITTAL Page

    Job Name:

    Job Number:

    Model Numbers:

    Switch with Occupancy/ Vacancy Sensor

    Continued on next page...

    Wiring Diagram 5: Connect occupancy sensing switch to groundMulti-Location Installation (120 V~)1, 2, 3-OPS6M2U-DV 4, -VPS6M2U-DV 4

    Blue

    Green

    Ground

    Occupancy sensing switch3

    Black

    Ground

    120V~ 50/60Hz

    Brass BrassBlack

    Blue Blue

    Green Green

    Ground

    Hot/Live

    Neutral

    Load

    MA-AS or MSC-AS

    MA-AS or MSC-AS

    Bare

    Black Black

    1 Only one Occupancy sensing switch can be used per multi-location circuit.2 Asinglestandardmechanical3-wayswitchorupto9companionswitchesmaybeconnectedtomostOccupancysensingswitches.Standardmechanical3-way

    switchcannotbecombinedwithcompanionswitch.Totalblueterminalwirelengthmaybeupto150 ft(46 m).3 Occupancy sensing switch can be installed in any location.4 Green wire is connected to ground.5 Wirecoveredbywhitesleeveisconnectedtoneutral.

    Wiring Diagram 6: Connect occupancy sensing switch to neutralMulti-Location Installation (120 V~)1, 2, 3-OPS6M2U-DV 5, -VPS6M2U-DV 5withMA-ASorMSC-AS

    MA-AS or MSC-AS

    MA-AS or MSC-AS

    Blue

    WhiteGround

    Occupancy sensing switch3

    Black

    Ground

    120V~ 50/60Hz

    Brass BrassBlack

    Blue Blue

    Green Green

    Ground

    Hot/Live

    Neutral

    Load

    Bare

    Black Black

    Wiring Diagrams: Multi-location Installations

  • Maestro® Sensor

    369741a 12 11.15.12

    ® SPECIF ICAT ION SUBMITTAL Page

    Job Name:

    Job Number:

    Model Numbers:

    Switch with Occupancy/ Vacancy Sensor

    1 Only one Occupancy sensing switch can be used per multi-location circuit.2 Asinglestandardmechanical3-wayswitchorupto9companionswitchesmaybeconnectedtomostOccupancysensingswitches.Standardmechanical3-way

    switchcannotbecombinedwithcompanionswitch.Totalblueterminalwirelengthmaybeupto150 ft(46 m).3 Occupancy sensing switch can be installed in any location.4 Fanloadappliesto120V~only(notforusewith277V~).5 Green wire is connected to ground.6 Wirecoveredbywhitesleeveisconnectedtoneutral.

    Wiring Diagrams: Multi-location Installations (continued)

    Occupancy sensing switch3

    Black

    Blue

    Green

    Ground

    Black

    Blue

    Green

    Ground

    277V~ 50/60Hz

    Black

    Blue

    Green

    Ground

    Hot/Live

    Neutral

    Load

    RedRed

    Bare

    Black

    MA-AS-277 or MSC-AS-277

    MA-AS-277 or MSC-AS-277

    Wiring Diagram 7: Connect occupancy sensing switch to groundMulti-Location Installation (277 V~)1, 2, 3, 4-OPS6M2U-DV 5, -VPS6M2U-DV 5withMA-AS-277orMSC-AS-277

    Occupancy sensing switch3

    Black

    Blue

    WhiteGround

    Black

    Blue

    Green

    Ground

    277V~ 50/60Hz

    Black

    Blue

    Green

    Ground

    Hot/Live

    Neutral

    Load

    RedRed

    Bare

    Black

    MA-AS-277 or MSC-AS-277

    MA-AS-277 or MSC-AS-277

    Wiring Diagram 8: Connect occupancy sensing switch to neutralMulti-Location Installation (277 V~)1, 2, 3, 4-OPS6M2U-DV6, -VPS6M2U-DV6withMA-AS-277orMSC-AS-277

  • Maestro® Sensor

    369741a 13 11.15.12

    ® SPECIF ICAT ION SUBMITTAL Page

    Job Name:

    Job Number:

    Model Numbers:

    Switch with Occupancy/ Vacancy Sensor

    Colors and Finishes

    • Duetoprintinglimitations,colorsandfinishesshowncannotbeguaranteedtomatchactualproductcolorsperfectly.

    • Colorchipkeychainsareavailableformoreprecisecolormatching:– GlossFinishes:DG-CK-1– SatinFinishes:SC-CK-1

    Satin Finishes

    TaupeTP

    TurquoiseTQ

    PlumPL

    MerlotMR

    TerracottaTC

    SiennaSI

    MidnightMN

    HotHT

    Desert StoneDS

    EggshellES

    BiscuitBI

    SnowSW

    PalladiumPD

    GreenbriarGB

    BluestoneBG

    Mocha StoneMS

    GoldstoneGS

    Sea GlassSG

    StoneST

    LimestoneLS

    Gloss Finishes

    WhiteWH

    IvoryIV

    AlmondAL

    LightAlmondLA

    GrayGR

    BrownBR

    BlackBL

    A: B: C: D: E: F: G: 1H: 2I: 3J: 4K: 5L: 6M: 7N: 8O: 9P: 10Q: 11R: 12S: 13