2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-1© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
M-SerieS Single Zone SySteMS
MSZ-ge wall-Mount Heat puMp SySteMS 1. Indoor UnItS ................................................................................................................................................MSZ-GE-2
2. oUtdoor UnItS ............................................................................................................................................MSZ-GE-3
3. SYStEM............................................................................................................................................................MSZ-GE-4
3-1.Specifications ..................................................................................................................................MSZ-GE-4
3-2.ExternalDimensions ..................................................................................................................... MSZ-GE-11
3-3.CenterofGravity ...........................................................................................................................MSZ-GE-16
3-4.ElectricalWiringDiagrams ............................................................................................................MSZ-GE-17
3-5.RefrigerantSystemDiagrams .......................................................................................................MSZ-GE-23
3-6.CapacityCorrectionCurvebyTemperature ..................................................................................MSZ-GE-28
3-7.CapacityCorrectionTablebyTemperature ...................................................................................MSZ-GE-30
3-8.CapacityCorrectionCurvebyRefrigerantPipingLength .............................................................MSZ-GE-34
3-9.CapacityCorrectionTablebyRefrigerantPipingLength ..............................................................MSZ-GE-35
3-10.ChargeCalculations ....................................................................................................................MSZ-GE-37
3-11.AirFlowData ...............................................................................................................................MSZ-GE-38
3-12.SoundPressureLevels ...............................................................................................................MSZ-GE-39
3-13.StandardOperationRange .........................................................................................................MSZ-GE-49
3-14.Accessories .................................................................................................................................MSZ-GE-50
MSZ-GE-2 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
1. inDoor unitS
• MSZ-GE06nA-8*• MSZ-GE09nA-8• MSZ-GE12nA-8• MSZ-GE15nA-8• MSZ-GE18nA-8• MSZ-GE24nA
*TheMSZ-GE06NA-8isonlycompatiblewiththemulti-splitMXZheatpumpsystems.
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-3© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
2. outDoor unitS
• MUZ-GE09nA• MUZ-GE12nA• MUZ-GE15nA-1• MUZ-GE18nA-1• MUZ-GE24nA
MSZ-GE-4 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-1. SpeCiFiCationS• Wall-mountedindoorunitforresidentialapplication• StandardHybridCatechinPrefilterandanti-allergyenzymefilterforhighair-purificationabilities• Quietoperation• Updatedsleek,compactindoorunitdesign• Integratedi-seeSensorautomaticallyadjuststheunit’soperationaccordingtothetemperaturedifferencesdetectedbetweenthefloorandtheintakeair,ensuringoptimumcomfortandenergyusage
• Baseheaterisavailableasanoption• Autofanspeedcontrol:Quiet,Low,Medium,High,andSuperHigh• Hand-heldWirelessRemoteController• Advancedmicroprocessorcontrol• Autorestartfollowingapoweroutage• Anti-allergyEnzymeFilter• Limitedwarranty:fiveyearspartsandsevenyearscompressor
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-5© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-1. SpeCiFiCationS
Modelname MSZ-ge06na-8 MSZ-ge09na-8 MSZ-ge12na-8
Powersupply V,phase,Hz 208/230, 1, 60
Max.fusesize(timedelay)/Disconnectswitch A 15
Min.circuitampacity A 1.0
BlowerMotor(ECM) F.L.A 0.76
AirflowSuperHigh-High-Med. -Low-Quiet
COOLDry (Wet) CFM 399-321-237-170-145
(364-286-201-134-109)
HEATDry CFM 406-321-233-170-145 406-321-237-170-145
Moistureremoval pt./h – 1.5 2.5
SensibleHeatFactor 0.82 0.74 0.80
SoundlevelSuperHigh-High-Med. -Low-Quiet
Cooling dB(A)43-37-30-22-19
45-37-30-22-19
Heating dB(A) 43-37-30-22-19
Cond.drainconnectionO.D. in. 5/8
Dimensions
W
in.
31-7/16
d 9-1/8
H 11-5/8
Weight Ib. 22
Externalfinish Munsell 1.0Y 9.2/0.2
Controlvoltage(bybuilt-intransformer) 12 - 24 VdC
Modelname MSZ-ge15na-8 MSZ-ge18na-8
Powersupply V,phase,Hz 208/230, 1, 60
Max.fusesize(timedelay)/Disconnectswitch A 15
Min.circuitampacity A 1.0
BlowerMotor(ECM) F.L.A 0.76
AirflowSuperHigh-High-Med. -Low-Quiet
COOLDry(Wet) CFM 533-420-335-272-205
(498-385-300-237-170)533-420-339-275-230(498-385-304-240-194)
HEATDry CFM 463-367-304-247-205 512-431-339-275-230
Moistureremoval pt./h 2.7 4.6
SensibleHeatFactor 0.71 0.75
SoundlevelSuperHigh-High-Med. -Low-Quiet
Cooling dB(A) 49-44-38-32-26 49-44-38-33-28
Heating dB(A) 46-40-35-30-26 48-43-38-33-28
Cond.drainconnectionO.D. in. 5/8
Dimensions
W
in.
31-7/16
d 9-1/8
H 11-5/8
Weight Ib. 22
Externalfinish Munsell 1.0Y 9.2/0.2
Controlvoltage(bybuilt-intransformer) 12 - 24 VdC note:TestconditionsarebasedonARI210/240.
MSZ-ge06na-8 MSZ-ge09na-8 MSZ-ge12na-8 MSZ-ge15na-8 MSZ-ge18na-8
MSZ-GE-6 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-1. SpeCiFiCationS
Modelname MSZ-ge24na
Powersupply V,phase,Hz 208/230, 1, 60
Max.fusesize(timedelay)/Disconnectswitch A 20
Min.circuitampacity A 1.0
BlowerMotor(ECM) F.L.A 0.76
AirflowSuperHigh-High-Med. -Low-Quiet
COOLDry(Wet) CFM 738-628-469-388
(661-562-420-347)
HEATDry CFM 406-321-237-170-145
Moistureremoval pt./h 5.1
SensibleHeatFactor 0.75
SoundlevelSuperHigh-High-Med. -Low-Quiet
Cooling dB(A) 53-49-41-34
Heating dB(A) 52-49-41-32
Cond.drainconnectionO.D. in. 5/8
Dimensions
W
in.
43-5/16
d 9-3/8
H 12-13/16
Weight Ib. 37
Externalfinish Munsell 1.0Y 9.2/0.2
Controlvoltage(bybuilt-intransformer) 12 - 24 VdC
note:TestconditionsarebasedonARI210/240. 1:Ratingconditions (Cooling)—Indoor:80˚FDB,67˚FWB,Outdoor:95˚FDB,(75˚FWB) Ratedfrequency (Heating)—Indoor:70˚FDB,60˚FWB,Outdoor:47˚FDB,43˚FWB Ratedfrequency 2: (Heating)—Indoor:70˚FDB,60˚FWB,Outdoor:17˚FDB,15˚FWB Maximumfrequency
MSZ-ge24na
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-7© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-1. SpeCiFiCationS
Modelname MuZ-ge09na MuZ-ge12na
CapacityRated(Minimum~Maximum)
Cooling 1 Btu/h 9,000(3,800~12,200)
12,000(3,800~13,600)
Heating47 1 Btu/h 10,900(4,500~14,100)
14,400(5,500~18,100)
Capacity Heating17 2 Btu/h 8,700 11,200
PowerconsumptionRated(Minimum~Maximum)
Cooling 1 W 660(205~1,200) 960(205~1,300)
Heating47 1 W 760(255~1,200) 1,170(340~1,660)
Powerconsumption Heating17 2 W 950 1,200
EEr 1 [SEEr] 3 Cooling 13.6 [ 21.0 ] 12.5 [ 20.5 ]
HSPFIV 4 Heating 10.0 10.0
COP Heating 1 4.20 3.61
Powersupply V,phase,Hz 208/230 , 1 , 60
Max.fusesize(timedelay) A 15
Min.circuitampacity A 12 12
FanMotor(ECM) F.L.A 0.50
Compressor
Model KNB073FQDHC KNB092FQAHC
R.L.A 6.6 6.6
L.R.A 8.2 8.2
Refrigerationoilcc.(Model) 320(NEO22)
Refrigerantcontrol Linearexpansionvalve
Soundlevel 1Cooling dB(A) 46 49
Heating dB(A) 50 51
Defrostmethod Reversecycle
Dimensions
W in. 31-1/2
d in. 11-1/4
H in. 21-5/8
Weight Ib. 66 77
Externalfinish Munsell 3Y 7.8/1.1
Remotecontroller Wirelesstype
Controlvoltage(bybuilt-intransformer) VdC 12 - 24
Refrigerantpiping Notsupplied
Refrigerantpipesize(Min.wallthickness)
Liquid in. 1/4(0.0315)
Gas in. 3/8(0.0315)
ConnectionmethodIndoor Flared
Outdoor Flared
Betweentheindoor&outdoorunits
Heightdifference ft. 40
Pipinglength ft. 65
Refrigerantcharge(R410A) 1lb.12oz. 2lb.9oz. note:TestconditionsarebasedonARI210/240. 1:Ratingconditions (Cooling)—Indoor:80˚FDB,67˚FWB,Outdoor:95˚FDB,(75˚FWB) Ratedfrequency (Heating)—Indoor:70˚FDB,60˚FWB,Outdoor:47˚FDB,43˚FWB Ratedfrequency 2: (Heating)—Indoor:70˚FDB,60˚FWB,Outdoor:17˚FDB,15˚FWB Maximumfrequency
MuZ-ge09na-1 MuZ-ge12na
MSZ-GE-8 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-1. SpeCiFiCationS
Modelname MuZ-ge15na-1 MuZ-ge18na-1
CapacityRated(Minimum~Maximum)
Cooling 1 Btu/h 14,000(3,100~18,200)
17,200(3,700~18,700)
Heating47 1 Btu/h 18,000(4,800~20,900)
21,600(3,500~25,200)
Capacity Heating17 2 Btu/h 15,900 17,200
Powercon-sumptionRated(Minimum~Maximum)
Cooling 1 W 1,080(160~2,000) 1,640(240~2,070)
Heating47 1 W 1,600(270~2,010) 1,900(230~2,680)
Powerconsumption Heating17 2 W 1,950 2,080
EEr 1 [SEEr] 3 Cooling 13.0 [ 21.0 ] 10.5 [19.2]
HSPFIV 4 Heating 10.0 10.0
COP Heating 1 3.30 3.33
Powersupply V,phase,Hz 208/230 , 1 , 60
Max.fusesize(timedelay) A 15
Min.circuitampacity A 12 14
FanMotor(ECM) F.L.A 0.50 0.93
Compressor
Model SNB130FQBH
R.L.A 7.4 10.0
L.R.A 9.3 12.5
Refrigerationoilcc.(Model) 450(NEO22)
Refrigerantcontrol Linearexpansionvalve
Soundlevel 1Cooling dB(A) 49 54
Heating dB(A) 51 56
Defrostmethod Reversecycle
Dimensions
W in. 31-1/2 33-1/16
d in. 11-1/4 13
H in. 21-5/8 33-7/16
Weight Ib. 80 119
Externalfinish Munsell 3Y 7.8/1.1
Remotecontroller Wirelesstype
Controlvoltage(bybuilt-intransformer) VdC 12 - 24
Refrigerantpiping Notsupplied
Refrigerantpipesize(Min.wallthickness)
Liquid in. 1/4(0.0315)
Gas in. 1/2(0.0315)
ConnectionmethodIndoor Flared
Outdoor Flared
Betweentheindoor&outdoorunits
Heightdifference ft. 40 50
Pipinglength ft. 65 100
Refrigerantcharge(R410A) 2lb.9oz. 3lb.7oz. note:TestconditionsarebasedonARI210/240. 1:Ratingconditions (Cooling)—Indoor:80˚FDB,67˚FWB,Outdoor:95˚FDB,(75˚FWB) Ratedfrequency (Heating)—Indoor:70˚FDB,60˚FWB,Outdoor:47˚FDB,43˚FWB Ratedfrequency 2: (Heating)—Indoor:70˚FDB,60˚FWB,Outdoor:17˚FDB,15˚FWB Maximumfrequency
MuZ-ge15na-1 MuZ-ge18na-1
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-9© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-1. SpeCiFiCationS
Modelname MuZ-ge24na
CapacityRated(Minimum~Maximum)
Cooling 1 Btu/h 22,500 (8,200~31,400)
Heating47 1 Btu/h 16,000(24,600)
Capacity Heating17 2 Btu/h 1,800(570~3,580)
PowerconsumptionRat-ed(Minimum~Maximum)
Cooling 1 W 16,000(24,600)
Heating47 1 W 2,340(520~3,650)
Powerconsumption Heating17 2 W 1,770(3,290)
EEr 1 [SEEr] 3 Cooling 12.5 [19.0]
HSPFIV 4 Heating 10.0
COP Heating 1 3.46
Powersupply V,phase,Hz 208/230 , 1 , 60
Max.fusesize(timedelay) A 20
Min.circuitampacity A 17.1
FanMotor(ECM) F.L.A 0.93
Compressor
Model SnB172FQKMt
R.L.A 12.9
L.R.A 16.1
Refrigerationoilcc.(Model) 0.40(FV50S)
Refrigerantcontrol Linearexpansionvalve
Soundlevel 1Cooling dB(A) 55
Heating dB(A) 55
Defrostmethod ReverseCycle
Dimensions
W in. 33-1/16
d in. 13
H in. 34-5/8
Weight Ib. 119
Externalfinish Munsell 3Y 7.8/1.1
Remotecontroller Wirelesstype
Controlvoltage(bybuilt-intransformer) VdC 12 - 24
Refrigerantpiping Notsupplied
Refrigerantpipesize(Min.wallthickness)
Liquid in. 3/8(0.0315)
Gas in. 5/8(0.0315)
ConnectionmethodIndoor Flared
Outdoor Flared
Betweentheindoor &outdoorunits
Heightdifference ft. 50
Pipinglength ft. 100
Refrigerantcharge(R410A) 4lb.3oz. note:TestconditionsarebasedonARI210/240. 1:Ratingconditions (Cooling)—Indoor:80˚FDB,67˚FWB,Outdoor:95˚FDB,(75˚FWB) Ratedfrequency (Heating)—Indoor:70˚FDB,60˚FWB,Outdoor:47˚FDB,43˚FWB Ratedfrequency 2: (Heating)—Indoor:70˚FDB,60˚FWB,Outdoor:17˚FDB,15˚FWB Maximumfrequency
MuZ-ge24na
MSZ-GE-10 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-1. SpeCiFiCationS
eFFiCienCy ratingS
outdoor unit indoor unit Seer eer HSpF Cop @ 47° F
Cop @ 17° F
energy Star
tax Credit
Most Efficient
wall-Mount Heat puMpMUZ-GE09nA MSZ-GE09nA-8 21 13.6 10 4.2 2.76 Yes Yes Yes
MUZ-GE12nA MSZ-GE12nA-8 20.25 12.5 10 3.6 2.86 Yes Yes Yes
MUZ-GE15nA-1 MSZ-GE15nA-8 21 13 10 3.3 2.88 Yes Yes Yes
MUZ-GE18nA-1 MSZ-GE18nA-8 19.2 10.5 10 3.32 2.7
MUZ-GE24nA MSZ-GE24nA 19 12.5 10 3.46 2.64 Yes Yes
Note: EfficiencyvaluesbasedonAHRI210/240testmethod.
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-11© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-2. eXternal DiMenSionS
MSZ-ge09na-8 MSZ-ge12na-8 MSZ-ge15na-8 MSZ-ge18na-8
8-5/16
9-1/8
9-15/16
7/8
6-1/
86-
1/8
3-1/
83-
1/8
8-7/
88-
7/8
1/8
3/4
6 - 1/4
2- 5
/16
3/16
9-1/
8
2-3/162-3/4
31-7
/16
30-1
5/16
1/4
5-1/
824
-3/8
1-15
/16
11-5/8
1-15
/16
1-5/8
2-3/
16
1-11/16
1-5/
8
5/16
3-15/16
4/3/
16
4-3/
8
1-3/
4
2-3/162-11/16
13-5
/16
2-3/
8
8-3/810
1-5/8
1-5/8
13-9
/16
2-1/
8
7/16
×1 O
blon
g ho
le7/
16×1
3/16
Obl
ong
hole
Inst
alla
tion
plat
e
Indo
or u
nit
Wal
l hol
e ø2
-9/1
6Ai
r in
Air o
ut
Inst
alla
tion
plat
e
Pipi
ng
Drai
n ho
se
MSZ-GE-12 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-2. eXternal DiMenSionS
Unit: inchMSZ-ge24na
10-1
/4
6-1/4
3/4
2-5/16
1-7/8
5/16 12-3/810-1/16 1-7/8
1/8
3-7/8
6-13
/16
3-7/8
6-13/1
616
-5/1
616
-5/1
6
3/16
9-15
/16
31-1
/82-3
/16
42-1
/16
43-5
/16
12-13/16
Air o
ut
Air i
n
Insu
latio
n ø1
-1/8
Drai
n ho
se ø
5/8
(Con
nect
ed p
art O
.D)
Inst
alla
tion
plat
e
Wal
l hol
e ø3
Wire
less
rem
ote
cont
rolle
r
Inst
alla
tion
plat
eIn
door
uni
t
{Liqu
id lin
eø1
/4 1
9-11
/16
Gas
line
ø5/8
16-
15/1
6In
sula
tion
ø1-1
5/16
O.D
ø1-1
/4 I.
D
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-13© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
MuZ-ge09na MuZ-ge12na MuZ-ge15na-1
Liqu
id p
ipe
:1/4
(fla
red)
Gas
pip
e :3
/8 (f
lare
d) (G
E09/
12)
1
/2 (f
lare
d) (G
E15)
6-23/3
2
2
5-7/8
2-23
/32
1-3/4
15-3
/4
12 ~ 12-3/413-9/16
11/16
1-9/
16
7/8
21-5/8
11-1/3213/32
31-1
/219
-11/
165-1
5/16
11-29
/32
17/3
229
/32
11-1
/4
Air i
n
hand
le
Air i
n Air o
ut
2- 3
/8
13/
16 O
val h
ole
Dra
in h
ole
1-
5/8
REQ
UIRE
D SP
ACE
Basic
ally
open
4 in
ch o
r mor
e wi
thou
t any
obs
truct
ion
in fr
ont
and
on b
oth
sides
of t
he u
nit.
14 in
. or m
ore
8 in
. or m
ore
4 in.
or m
ore
4 in.
or m
ore
Ope
n tw
o si
des
of le
ft,
right
, or r
ear s
ide.
3-2. eXternal DiMenSionS
MSZ-GE-14 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
Unit: inchMuZ-ge18na-1
20-9
/32
14-3/16
Air i
n11
-25/
322-
19/3
2
Air i
n
Air o
ut 19-1
1/16
33-1
/16
13
2
4-25
/32
33-7/16
16-15/16
3-3/
16
4-3/
8 ×
13/1
6 sl
ot1-11/32
1-9/
16D
rain
3 h
oles
(ø
1-5/
16)
30°35°
2-9/16
Liqu
id:1
/4(fl
ared
)G
as
:1/2
(flar
ed)
3-9/168-
11/3
2
Ope
n as
a ru
le20
inch
or m
ore
ifth
e fro
nt a
nd b
oth
side
s ar
e op
en 4 in
ch o
r mor
e/8
inch
or m
ore
if th
ere
are
obst
acle
sto
bot
h si
des
Ope
n as
a ru
le20
inch
or m
ore
if th
e ba
ck,
both
sid
es a
nd to
p ar
e op
en
REQ
UIRE
D SP
ACE
14 in
. or m
ore
4 in
. or m
ore
3-2. eXternal DiMenSionS
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-15© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
MuZ-ge24na
30° 35°
6-1/283-17/32
7-25
/32
1-9/
16
20-9
/32
11-2
5/32
2-19
/32
2
14-3/16
33-7/1616-15/16
19-1
1/16
3-3/
164-
25/3
233
-1/1
6
Ope
n as
a ru
le20
inch
or m
ore
ifth
e fro
nt a
nd b
oth
side
s ar
e op
en 4 in
ch o
r mor
e /
8 in
ch o
r mor
e if
ther
e ar
e ob
stac
les
to b
oth
side
s
Ope
n as
a ru
le20
inch
or m
ore
if th
e ba
ck,
both
sid
es a
nd to
p ar
e op
en
14 in
. or m
ore
4 in
. or m
ore
Air
in
Air
out
13
Ser
vice
pan
el
Gas
refri
gera
nt
pipe
join
tR
efrig
eran
t pip
e(fl
ared
) ø5/
8
Liqu
id re
frige
rant
pi
pe jo
int
Ref
riger
ant p
ipe
(flar
ed) ø
1/4
Dra
in h
ole
ø1-5
/8
4-3/
8
13/1
6 O
val h
ole
REQ
UIR
ED S
PAC
E
Air
in
3-2. eXternal DiMenSionS
Unit: inch
MSZ-GE-16 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-3. Center oF graVity
cC
A
a b
B
a bB
cC
A
Unit: inch(mm)
Model name a B C a b c
MSZ-ge09na-8MSZ-ge12na-8MSZ-ge15na-8MSZ-ge18na-8
13-7/16(340)
3-3/4(95)
7-1/2(190)
31-7/16(798)
9-1/8(232)
11-5/8(295)
MSZ-ge24na 17-11/16(450)
4-5/16(110)
6-5/16(160)
42-1/16(1100)
10-1/4(261)
12-13/16(325)
Unit: inch(mm)
Model name a B C a b c
MuZ-ge09naMuZ-ge12naMuZ-ge15na-1
11-1/16(280)
5-9/16(140)
9-1/2(240)
31-1/2(800)
11-1/4(285)
21-5/8(550)
MuZ-ge18na-1 11-13/16(300)
5-7/8(150)
13-3/8(340)
33-1/16(840)
13(330)
33-7/16(850)MuZ-ge24na
MSZ-ge09na-8 MSZ-ge12na-8 MSZ-ge15na-8 MSZ-ge18na-8 MSZ-ge24na
MuZ-ge09na MuZ-ge12na MuZ-ge15na-1 MuZ-ge18na-1 MuZ-ge24na
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-17© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-4. eleCtriCal wiring DiagraMS
MSZ-ge09na-8 MSZ-ge12na-8 MSZ-ge15na-8 MSZ-ge18na-8
MSZ-GE-18 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-4. eleCtriCal wiring DiagraMS
MSZ-ge24na
8
MSZ
-GE0
6NA
MSZ
-GE0
9NA
MSZ
-GE1
2NA
MSZ
-GE1
5NA
MSZ
-GE1
8NA
MSY
-GE0
9NA
MSY
-GE1
2NA
MSY
-GE1
5NA
MSY
-GE1
8NA
5W
IRIN
G D
IAG
RAM
MSZ
-GE2
4NA
MSY
-GE2
4NA
OBH
548C
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-19© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-4. eleCtriCal wiring DiagraMS
MuZ-ge09na MuZ-ge12na
MSZ-GE-20 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-4. eleCtriCal wiring DiagraMS
MuZ-ge15na-1
11
MU
Z-G
E15N
A
MU
Z-G
E15N
A-
1
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-21© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-4. eleCtriCal wiring DiagraMS
MuZ-ge18na-1
13
MU
Z-G
E18N
A
MU
Z-G
E18N
A-
1
MSZ-GE-22 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-4. eleCtriCal wiring DiagraMS
15
MuZ-ge24na
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-23© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-5. reFrigerant SySteM DiagraMS
Indoorheatexchanger Flared connection
Room temperaturethermistorRT11
Flared connection
Refrigerant pipe ø3/8 (MSZ-GE06/09/12NA, MSY-GE09/12NA) ø1/2 (MSZ-GE15/18NA, MSY-GE15/18NA)(with heat insulator)
Refrigerant pipe ø1/4(with heat insulator)
Indoor coil thermistorRT12 (main)
Indoor coil thermistorRT13 (sub)
Refrigerant flow in coolingRefrigerant flow in heating
Indoorheatexchanger
Roomtemperaturethermistorrt11
Refrigerantpipeø5/8(withheatinsulator)
Flaredconnection
Flaredconnection
IndoorcoilthermistorRT12(main)
Refrigerantpipeø1/4(withheatinsulator)
Distributor
IndoorcoilthermistorRT13(sub)
MSZ-ge24na
MSZ-ge09na-8 MSZ-ge12na-8 MSZ-ge15na-8 MSZ-ge18na-8
MSZ-GE-24 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-5. reFrigerant SySteM DiagraMS
Unit: inch
Out
door
heat
exch
ange
rFl
ared
con
nect
ion
Def
rost
ther
mis
tor
RT6
1(M
UZ)
Dis
char
gete
mpe
ratu
reth
erm
isto
rR
T62
Flar
ed c
onne
ctio
n
Sto
p va
lve
(with
stra
inar
)
Sto
p va
lve
(with
ser
vice
por
t)
Ref
riger
ant f
low
in c
oolin
g
Com
pres
sor
4-w
ay v
alve
Ref
riger
ant f
low
in h
eatin
g (M
UZ)
Ref
riger
ant p
ipe
ø3/
8(w
ith h
eat i
nsul
ator
)
Ref
riger
ant p
ipe
ø1/
4(w
ith h
eat i
nsul
ator
)
R.V
. coi
l (M
UZ)
heat
ing
ON
cool
ing
OFF
Stra
iner
#100
LEV
Am
bien
t te
mpe
ratu
re
ther
mis
tor
RT6
5
Muf
fler
Cap
illar
y tu
beO
.D. 0
.118
× I.
D. 0
.079
× 9
-7/1
6(ø
3.0
× ø2
.0 ×
240
)
Out
door
hea
tex
chan
ger
tem
pera
ture
th
erm
isto
rR
T68
Ser
vice
por
t
Ser
vice
por
t
Muf
fler
MuZ-ge09na
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-25© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-5. reFrigerant SySteM DiagraMS
Out
door
heat
exch
ange
rFl
ared
con
nect
ion
Def
rost
ther
mis
tor
RT6
1(M
UZ)
Dis
char
gete
mpe
ratu
reth
erm
isto
rR
T62
Flar
ed c
onne
ctio
n
Sto
p va
lve
(with
stra
inar
)
Sto
p va
lve
(with
ser
vice
por
t)
Ref
riger
ant f
low
in c
oolin
g
Com
pres
sor
4-w
ay v
alve
Ref
riger
ant f
low
in h
eatin
g (M
UZ)
Ref
riger
ant p
ipe
ø3/
8 (G
E12N
A)
Ref
riger
ant p
ipe
ø1/
2 (G
E15N
A)
(with
hea
t ins
ulat
or)
Ref
riger
ant p
ipe
ø1/
4(w
ith h
eat i
nsul
ator
)
R.V
. coi
l (M
UZ)
heat
ing
ON
cool
ing
OFF
Stra
iner
#100
Cap
illar
y tu
beO
.D. 0
.118
× I.
D. 0
.071
× 2
3-5/
8(ø
3.0
× ø1
.8 ×
600
) (×2
)
LEV
Am
bien
t te
mpe
ratu
re
ther
mis
tor
RT6
5
Muf
fler
Cap
illar
y tu
beO
.D. 0
.118
× I.
D. 0
.079
× 9
-7/1
6(ø
3.0
× ø2
.0 ×
240
)
Out
door
hea
tex
chan
ger
tem
pera
ture
th
erm
isto
rR
T68
Muf
fler
Ser
vice
por
t
Ser
vice
por
t
MuZ-ge12na MuZ-ge15na-1
MSZ-GE-26 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-5. reFrigerant SySteM DiagraMS
Unit: inch
Out
door
heat
exch
ange
rFl
ared
con
nect
ion
Defro
stth
erm
istor
RT61
(MU
Z)
Dis
char
gete
mpe
ratu
reth
erm
isto
rR
T62
Flar
ed c
onne
ctio
n
Sto
p va
lve
(with
stra
inar
)
Stop
val
ve(w
ith s
ervi
ce p
ort)
Cap
illar
y tu
beO
.D. 0
.142
× I.
D. 0
.094
× 1
-31/
32(ø
3.6×
ø2.4
×50)
Ref
riger
ant f
low
in c
oolin
g
Com
pres
sor
4-w
ay v
alve
Ref
riger
ant f
low
in h
eatin
g (M
UZ)
Ref
riger
ant p
ipe
ø1/2
(with
hea
t ins
ulat
or)
Ref
riger
ant p
ipe
ø1/4
(with
hea
t ins
ulat
or)
LEV
R.V
. coi
l (M
UZ)
heat
ing
ON
cool
ing
OFF
Muf
fler
#100
Rec
eive
r
Out
door
hea
t ex
chan
ger
tem
pera
ture
ther
mis
tor
RT6
8
Am
bien
tte
mpe
ratu
reth
erm
isto
rR
T65
Stra
iner
#100
Serv
ice
port
Serv
ice
port
MuZ-ge18na-1
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-27© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-5. reFrigerant SySteM DiagraMS
Out
door
heat
exch
ange
rFl
ared
con
nect
ion
Dis
char
gete
mpe
ratu
reth
erm
isto
rR
T62
Flar
ed c
onne
ctio
n
Sto
p va
lve
Stop
val
ve(w
ith s
ervi
ce p
ort)
Cap
illar
y tu
beR
efrig
eran
t flo
w in
coo
ling
Com
pres
sor
Ser
vice
port
Ser
vice
port
4-w
ay v
alve
Ref
riger
ant p
ipe
ø5/8
(with
hea
t ins
ulat
or)
Ref
riger
ant p
ipe
ø1/4
(with
hea
t ins
ulat
or)
LEV
Muf
fler
#100
Stra
iner
#100
Rec
eive
r
Out
door
hea
t ex
chan
ger
tem
pera
ture
ther
mis
tor
RT6
8
Am
bien
tte
mpe
ratu
reth
erm
isto
rR
T65
Stra
iner
#100
O.D
. 0.1
42 ×
I.D
. 0.0
94×
1-31
/32
(ø3.
6 ×
ø2.4
× 5
0)
MuZ-ge24na
MSZ-GE-28 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-6. CapaCity CorreCtion CurVe By teMperature
MuZ-ge09na
716763
716763
13121110
7
98
0.7
0.6
0.5
Indoor intake air WB temperature (°F)
Indoor intake air WB temperature (°F)
SHF at rating condition = 0.76= 307 CFMAirflow
65 75 85 95 105 115Outdoor intake air DB temperature (°F)
Tota
l pow
er c
onsu
mpt
ion
(kW
)To
tal c
apac
ity
( 1
03 B
tu/h
)
MuZ-ge12na
71
6367
71
6367
1415
12
10
13
11
9
1.2
1.1
1.0
0.9
0.8
0.7
Indoor intake air WB temperature (°F)
Indoor intake air WB temperature (°F)
SHF at rating condition = 0.73= 350 CFMAirflow
65 75 85 95 105 115Outdoor intake air DB temperature (°F)
Tota
l pow
er c
onsu
mpt
ion
(kW
)To
tal c
apac
ity
( 1
03 B
tu/h
)
MuZ-ge15na-1
716763
716763
1718
161514
11
1312
1.3
1.2
1.1
1.0
0.9
0.8
Indoor intake air WB temperature (°F)
Indoor intake air WB temperature (°F)
SHF at rating condition = 0.80= 498 CFMAirflow
65 75 85 95 105 115Outdoor intake air DB temperature (°F)
Tota
l pow
er c
onsu
mpt
ion
(kW
)To
tal c
apac
ity
( 1
03 B
tu/h
)
MuZ-ge18na-1
716763
716763
2122
20
1819
17
14
1615
1.9
1.8
1.7
1.6
1.5
1.4
1.3
Indoor intake air WB temperature (°F)
Indoor intake air WB temperature (°F)
SHF at rating condition = 0.71= 498 CFMAirflow
65 75 85 95 105 115Outdoor intake air DB temperature (°F)
Tota
l pow
er c
onsu
mpt
ion
(kW
)To
tal c
apac
ity
( 1
03 B
tu/h
)
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-29© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-6. CapaCity CorreCtion CurVe By teMperature
MuZ-ge24na
Due to Continuing reSearCH anD proDuCt iMproVeMent,
SpeCiFiCationS anD Data are Still unDer reView
MSZ-GE-30 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-7. CapaCity CorreCtion taBle By teMperature
1) C
OO
LIN
G C
APA
CIT
Y(1) MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA-1 MUZ-GE18NA-1
Model
Indoorair
OutdoorintakeairDBtemperature(˚F)
IWB(˚F)
7585
9510
511
5
tC
SHC
TPC
tC
SHC
TPC
tC
SHC
TPC
tC
SHC
TPC
tC
SHC
TPC
Mu
Z-g
e09n
a71
11.0
7.6
0.59
10.3
7.1
0.64
9.7
6.6
0.69
9.0
6.2
0.73
8.3
5.7
0.76
6710
.48.
60.
559.
78.
00.
619.
07.
40.
668.
46.
90.
707.
76.
30.
73
639.
89.
40.
539.
18.
70.
588.
58.
10.
637.
77.
30.
677.
06.
70.
70
Mu
Z-g
e12n
a71
14.7
8.9
0.85
13.7
8.3
0.94
12.9
7.8
1.01
12.0
7.3
1.06
11.0
6.7
1.10
6713
.910
.30.
8113
.09.
60.
8912
.08.
90.
9611
.28.
31.
0210
.37.
61.
07
6313
.111
.40.
7712
.110
.60.
8511
.39.
90.
9210
.39.
00.
989.
48.
21.
02
Mu
Z-g
e15n
a-1
71
17.2
11.4
0.96
16.0
10.7
1.05
15.1
10.0
1.13
14.0
9.3
1.19
12.9
8.6
1.24
6716
.213
.00.
9115
.112
.11.
0014
.011
.21.
0813
.010
.41.
1412
.09.
61.
20
6315
.314
.20.
8614
.113
.20.
9613
.212
.31.
0312
.011
.21.
1010
.910
.21.
14
Mu
Z-g
e18n
a-1
7121
.112
.21.
4619
.711
.41.
6018
.510
.71.
7217
.29.
91.
8115
.89.
11.
89
6720
.014
.21.
3818
.613
.21.
5217
.212
.21.
6416
.011
.41.
7414
.710
.41.
82
6318
.715
.81.
3117
.414
.71.
4516
.213
.61.
5714
.712
.41.
6713
.411
.31.
74 n
ote
:1.IWB:Intakeairw
et-bulbtemperature
TC
:TotalC
apacity(×
103 Btu/h)
SHC:S
ensibleHeatC
apacity(×
103 Btu/h)
TP
C:TotalPow
erConsumption(kW)
2.SHCisbasedon80˚FofindoorIntakeairD
Btemperature.
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-31© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
2) H
EATI
NG
CA
PAC
ITY
Model
Indoor
air
OutdoorintakeairWBtemperature(˚F)
IDB(˚F)
515
2535
4345
55
tC
TPC
tC
TPC
tC
TPC
tC
TPC
tC
TPC
tC
TPC
tC
TPC
Mu
Z-g
e09n
a 75
4.8
0.45
6.3
0.57
7.9
0.67
9.4
0.74
10.6
0.78
11.0
0.79
12.4
0.82
705.
20.
436.
70.
558.
20.
659.
60.
7210
.90.
7611
.20.
7812
.70.
81
655.
50.
416.
90.
528.
60.
6310
.00.
7011
.20.
7411
.60.
7513
.00.
79
Mu
Z-g
e12n
a 75
6.3
0.69
8.4
0.87
10.4
1.02
12.5
1.14
14.0
1.20
14.5
1.22
16.4
1.26
706.
80.
668.
90.
8410
.81.
0012
.71.
1114
.41.
1714
.81.
1916
.81.
24
657.
20.
639.
10.
8111
.30.
9713
.21.
0814
.81.
1415
.31.
1617
.11.
22
Mu
Z-g
e15n
a-1
757.
90.
6310
.40.
7913
.10.
931.
561.
0317
.61.
0918
.11.
1020
.51.
14
708.
60.
6011
.10.
7613
.50.
9115
.91.
0118
.01.
0618
.51.
0821
.01.
12
659.
00.
5711
.30.
7314
.10.
8716
.50.
9818
.51.
0319
.11.
0521
.41.
10
Mu
Z-g
e18n
a-1
759.
10.
6411
.90.
8114
.90.
9517
.81.
0620
.11.
1220
.71.
1323
.51.
18
709.
80.
6212
.70.
7815
.50.
9318
.21.
0420
.61.
0921
.21.
1124
.01.
16
6510
.30.
5913
.00.
7516
.20.
9018
.81.
0121
.21.
0621
.81.
0824
.51.
13 n
ote
:1.IDB:Intakeairdry-bulbtemperature
TC
:TotalC
apacity(×
103 Btu/h)
TP
C:TotalPow
erConsumption(kW)
2.Abovedataisforheatingoperationwithoutanyfrost.
How
tooperatewithfixedoperationalfrequencyofthecom
pressor.
1.PresstheEMERGENCYOPERAT
IONswitchonthefrontoftheindoorunit,andselecteitherEMERGENCYCOOLmodeor
EMERGENCYHEAT
modebeforestartingtooperatetheairconditioner.
2.Thecom
pressorstartswithoperationalfrequency.
3.ThefanspeedoftheindoorunitisHigh.
4.Thisoperationcontinuesfor30minutes.
5.Inordertoreleasethisoperation,presstheEMERGENCYOPERAT
IONswitchtwiceoronce,orpressanybuttononthe
remotecontroller.
(2) MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA-1 MUZ-GE18NA-1
3-7. CapaCity CorreCtion taBle By teMperature
MSZ-GE-32 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-7. CapaCity CorreCtion taBle By teMperature
70 77 81 86 95 104 11560 1.11 1.06 1.01 0.97 0.91 0.83 0.76
63 1.16 1.10 1.06 1.02 0.96 0.88 0.81
64 1.18 1.13 1.08 1.04 0.98 0.90 0.83
68 1.23 1.18 1.14 1.10 1.03 0.96 0.89
72 1.28 1.23 1.20 1.15 1.09 1.02 0.95
75 1.34 1.29 1.26 1.22 1.15 1.08 1.02
79 1.38 1.34 1.32 1.28 1.21 1.14 1.07
(3) M-SERIES COOLING CORRECTION
outdoor intake
temperature w.B. [° F]
43 39 36 32 28 25 21 18 14
outdoor intake
temperature w.B. [° C]
6 4 2 0 -2 -4 -6 -8 -10
Correction factor 1.00 0.80 0.82 0.84 0.87 0.90 0.93 0.96 1.00
(4) M-SERIES DEFROST CORRECTION
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-33© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-7. CapaCity CorreCtion taBle By teMperature
outdoor w.B. [° F]-13 -4 5 14 23 32 41 50
indooreat DB
MUZ-GE24nA 60 0.81 0.95 0.99 1.03 1.07 1.07
MUZ-GE18nA-1 60 0.67 0.82 0.94 1.04 1.07 1.07
MUZ-GE15nA-1 60 0.77 0.93 0.99 1.01 1.07 1.07
MUZ-GE12nA 60 0.68 0.83 0.94 1.04 1.07 1.07
MUZ-GE09nA 60 0.69 0.85 0.98 1.07 1.07 1.07
Interpolated Data Between 60 and 65 Indoor EAT DB data setsMUZ-GE24nA 63 0.80 0.93 0.97 1.01 1.05 1.05
MUZ-GE18nA-1 63 0.66 0.81 0.92 1.02 1.05 1.05
MUZ-GE15nA-1 63 0.75 0.91 0.97 0.99 1.05 1.05
MUZ-GE12nA 63 0.67 0.82 0.93 1.02 1.05 1.05
MUZ-GE09nA 63 0.68 0.83 0.96 1.05 1.05 1.05
MUZ-GE24nA 65 0.79 0.92 0.96 1.00 1.03 1.03
MUZ-GE18nA-1 65 0.65 0.80 0.91 1.00 1.03 1.03
MUZ-GE15nA-1 65 0.74 0.90 0.96 0.97 1.03 1.03
MUZ-GE12nA 65 0.66 0.81 0.91 1.01 1.03 1.03
MUZ-GE09nA 65 0.67 0.82 0.94 1.03 1.03 1.03
MUZ-GE24nA 70 0.76 0.89 0.93 0.96 1.00 1.00
MUZ-GE18nA-1 70 0.63 0.77 0.88 0.97 1.00 1.00
MUZ-GE15nA-1 70 0.72 0.87 0.93 0.94 1.00 1.00
MUZ-GE12nA 70 0.64 0.78 0.88 0.97 1.00 1.00
MUZ-GE09nA 70 0.65 0.79 0.91 1.00 1.00 1.00
MUZ-GE24nA 75 0.73 0.86 0.89 0.93 0.96 0.96
MUZ-GE18nA-1 75 0.61 0.74 0.85 0.93 0.96 0.96
MUZ-GE15nA-1 75 0.69 0.84 0.90 0.91 0.96 0.96
MUZ-GE12nA 75 0.61 0.75 0.85 0.94 0.96 0.96
MUZ-GE09nA 75 0.62 0.77 0.88 0.96 0.96 0.96
MUZ-GE24nA 80 0.71 0.83 0.86 0.89 0.93 0.93
MUZ-GE18nA-1 80 0.58 0.71 0.82 0.90 0.93 0.93
MUZ-GE15nA-1 80 0.67 0.81 0.86 0.87 0.93 0.93
MUZ-GE12nA 80 0.59 0.72 0.82 0.90 0.93 0.93
MUZ-GE09nA 80 0.60 0.74 0.85 0.93 0.93 0.93
(5) M-SERIES HEATING CORRECTION
MSZ-GE-34 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-8. CapaCity CorreCtion CurVe By reFrigerant piping lengtH
Due to Continuing reSearCH anD proDuCt iMproVeMent,
SpeCiFiCationS anD Data are Still unDer reView
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-35© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-9. CapaCity CorreCtion taBle By reFrigerant piping lengtH
Refrigerantpipinglength(oneway:ft.)
25(std.) 40 65 100
MuZ-ge09naMuZ-ge12na MuZ-ge15na-1 MuZ-ge18na-1
1.0 0.954 0.878 -
MuZ-ge24na 1.0 0.954 0.878 0.771
Model
Refrigerantpiping:ft Pipingsize:in.
Additionalpiping
Max.lengthA
Additionalpiping
Max.heightB
Gas Liquid
Outsidediameter
MinimumWall
thicknessOutsidediameter
MinimumWall
thickness
MuZ-ge09na 65 40 3/8 0.0315 1/4 0.0315
MuZ-ge12na MuZ-ge15na-1 65 40 1/2 0.0315 1/4 0.0315
MuZ-ge18na-1 100 50 1/2 0.0315 3/8 0.0315
MuZ-ge24na 100 50 5/8 0.0315 3/8 0.0315
(2) Maximum refrigerant piping length & maximum height difference
Max. Height difference B
Additional PipingMax. length A
Indoorunit
Outdoor unit
(1) Cooling capacity correction
MSZ-GE-36 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-9. CapaCity CorreCtion taBle By reFrigerant piping lengtH
Refrigerant piping length (ft)25(std) 40 65 100
1.000 0.954 0.878 0.771
(3) M-SERIES PIPING CORRECTION COOLING
Refrigerant piping length (ft)25(std) 40 65 100
1.000 0.989 0.972 0.955
(4) M-SERIES PIPING CORRECTION HEATING
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-37© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-10. CHarge CalCulationS
Model Outdoorunitprecharged
Refrigerantpipinglength(oneway):ft.
25ft 30ft 40ft 50ft 60ft 65ft
MuZ-ge09na 1lb.12oz.
0 1.62 4.86 8.10 11.34 12.96MuZ-ge12na2lb.9oz.
MuZ-ge15na-1 note:Calculation:Xoz.=1.62/5oz./ft (Refrigerantpipinglength(ft)-25)
Model Outdoorunitprecharged
Refrigerantpipinglength(oneway):ft.
25 30 40 50 60 70 80 90 100
MuZ-ge15na-1 3lb.7oz. 0 1.08 3.24 5.40 7.56 9.72 11.88 14.04 16.20
note:Calculation:Xoz.=1.08/5oz./ft (Refrigerantpipinglength(ft)-25) note:Refrigerantpipingexceeding33ft.requiresadditionalrefrigerantchargeaccordingtothecalculation.
ModelOutdoor
unit precharged
Refrigerantpipinglength(oneway):ft.
33 40 50 60 70 80 90 100
MuZ-ge24na 4lb.3oz. 0 4.14 10.06 15.98 21.90 27.82 33.74 39.66 note:Calculation:Xoz.=2.96/5oz./ft (Refrigerantpipinglength(ft)-33)
(1) ADDITIONAL REFRIGERANT CHARGE (R410A: oz.)note:Refrigerantpipingexceeding25ft.requiresadditionalrefrigerantchargeaccordingtothecalcualation.
MSZ-GE-38 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-11. air Flow Data
●Theaircoverageisthefigureuptothepositionwheretheairspeedis1ft./s.,whenairisblownouthorizontallyfromtheunitproperlyattheHighspeedposition.
Thecoverageshouldbeusedonlyasageneralguidelinesinceitvariesaccordingtothesizeoftheroomandfurniturearrangedinsidetheroom.
Modelname Mode Function Airflow(CFM)
Airspeed(ft./s.) Coverage(ft.)
MSZ-ge06na-8
HEAT Dry 406 20.6 29.5
COOLDry 321 16.3 23.5
Wet 286 14.5 21.0
MSZ-ge09na-8
HEAT Dry 406 20.6 29.5
COOLDry 321 16.3 23.5
Wet 286 14.5 21.0
MSZ-ge12na-8
HEAT Dry 406 20.6 29.5
COOLDry 321 16.3 23.5
Wet 286 14.5 21.0
MSZ-ge15na-8
HEAT Dry 463 23.4 33.5
COOLDry 420 21.3 30.5
Wet 385 19.5 28.0
MSZ-ge18na-8
HEAT Dry 512 25.9 36.9
COOLDry 420 21.3 30.5
Wet 385 19.5 28.0
MSZ-ge24na
HEAT Dry 738 18.0 36.9
COOLDry 738 18.0 36.9
Wet 661 16.1 31.9
outlet air SpeeD anD CoVerage
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-39© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-12. SounD preSSure leVelS
MSy-ge06/09na-8
MSZ-GE-40 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-12. SounD preSSure leVelS
MSZ-ge12na-8
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-41© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-12. SounD preSSure leVelS
MSZ-ge15na-8
Due to Continuing reSearCH anD proDuCt iMproVeMent,
SpeCiFiCationS anD Data are Still unDer reView
MSZ-GE-42 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-12. SounD preSSure leVelS
MSZ-ge18na-8
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-43© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-12. SounD preSSure leVelS
Noise Criterion Curves
WALL
MSZ-GE24NAMSZ-GE24NAMSZ-GE24NAMSZ-GE24NA UNIT
MSZ-FE18NAMSZ-FE18NAMSZ-FE18NAMSZ-FE18NA 1m NOTCH SPL(dB(A)) LINE 0.8m COOL(Rated) 53535353 ● ●
HEAT(Rated) 53535353 □ □
MICROPHONE
Test conditions are based on JIS Z8731
Ambient temperature Cooling DB:27℃ WB:19℃ Heating DB:20℃ WB:15℃
10
20
30
40
50
60
70
80
90
63 125 250 500 1000 2000 4000 8000
BAND CENTER FREQUENCIES,Hz
OC
TAV
E BA
ND
SO
UN
D P
RESS
URE
LEV
EL,d
B re
0.0
02 M
ICRO
BA
R NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
APPROXIMATETHRESHOLD OFHEARING FORCONTINUOUS
NOISE
MSZ63-1.XLS
MSZ-ge24na
MSZ-GE-44 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-12. SounD preSSure leVelS
Noise Criterion Curves
MUZ-GE12NA UNIT
NOTCH SPL(dB(A)) LINE
1m COOL 49 ● ●
MICROPHONE HEAT 51 □ □
Test conditions are based on JIS Z8731
Ambient temperature Cooling DB:35℃ WB:24℃
Heating DB: 7℃ WB: 6℃
10
20
30
40
50
60
70
80
90
63 125 250 500 1000 2000 4000 8000
BAND CENTER FREQUENCIES,Hz
OCTAVE BAND SOUND PRESSURE LEVEL,dB re 0.002 MICRO BAR
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
APPROXIMATETHRESHOLD OFHEARING FORCONTINUOUS
NOISE
MuZ-ge09na
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-45© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-12. SounD preSSure leVelS
Noise Criterion Curves
MUZ-GE12NA UNIT
NOTCH SPL(dB(A)) LINE
1m COOL 49 ● ●
MICROPHONE HEAT 51 □ □
Test conditions are based on JIS Z8731
Ambient temperature Cooling DB:35℃ WB:24℃
Heating DB: 7℃ WB: 6℃
10
20
30
40
50
60
70
80
90
63 125 250 500 1000 2000 4000 8000
BAND CENTER FREQUENCIES,Hz
OCTAVE BAND SOUND PRESSURE LEVEL,dB re 0.002 MICRO BAR
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
APPROXIMATETHRESHOLD OFHEARING FORCONTINUOUS
NOISE
MuZ-ge12na
MSZ-GE-46 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-12. SounD preSSure leVelS
Noise Criterion Curves
MUZ-GE15NA UNIT
NOTCH SPL(dB(A)) LINE
1m COOL 49 ● ●
MICROPHONE HEAT 51 □ □
Test conditions are based on JIS Z8731
Ambient temperature Cooling DB:35℃ WB:24℃
Heating DB: 7℃ WB: 6℃
10
20
30
40
50
60
70
80
90
63 125 250 500 1000 2000 4000 8000
BAND CENTER FREQUENCIES,Hz
OCTAVE BAND SOUND PRESSURE LEVEL,dB re 0.002 MICRO BAR
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
APPROXIMATETHRESHOLD OFHEARING FORCONTINUOUS
NOISE
MuZ-ge15na-1
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-47© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-12. SounD preSSure leVelS
MuZ-ge18na-1
Due to Continuing reSearCH anD proDuCt iMproVeMent,
SpeCiFiCationS anD Data are Still unDer reView
MSZ-GE-48 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-12. SounD preSSure leVelS
Noise Criterion Curves
WALL
MSZ-GE24NAMSZ-GE24NAMSZ-GE24NAMSZ-GE24NA UNIT
MSZ-FE18NAMSZ-FE18NAMSZ-FE18NAMSZ-FE18NA 1m NOTCH SPL(dB(A)) LINE 0.8m COOL(Rated) 53535353 ● ●
HEAT(Rated) 53535353 □ □
MICROPHONE
Test conditions are based on JIS Z8731
Ambient temperature Cooling DB:27℃ WB:19℃ Heating DB:20℃ WB:15℃
10
20
30
40
50
60
70
80
90
63 125 250 500 1000 2000 4000 8000
BAND CENTER FREQUENCIES,Hz
OC
TAV
E BA
ND
SO
UN
D P
RESS
URE
LEV
EL,d
B re
0.0
02 M
ICRO
BA
R NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
APPROXIMATETHRESHOLD OFHEARING FORCONTINUOUS
NOISE
MSZ63-1.XLS
MSZ-ge24na
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-49© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-13. StanDarD operation range
Outdoor unit
Rating Guaranteed Voltage
Min. 187V Max. 253V 208V208/230V
60Hz 1 Phase
230V
Function
Cooling
Standard temperature
Maximum temperature
Minimum temperature
Maximum humidity
DB (°F)
80
95
67
WB (°F)
67
73
57
Indoor
78%
DB (°F)
95
115
67
WB (°F)
—
—
—
Outdoor
—
Condition
Intake air temperature
Heating
43
65
-15
47
75
-13
70
80
70
60
67
60
Standard temperature
Maximum temperature
Minimum temperature
(1) OUTDOOR UNITMuZ-ge09na MuZ-ge12na MuZ-ge15na-1 MuZ-ge18na-1 MuZ-ge24naoperating range(A)POWERSUPPLY
Ratedvoltage GuaranteedVoltage(V)
Outdoorunit208/230 V 1phase60Hz
Min.187 208 230 Max.253
(B)OPERATION
Mode Condition
Intakeairtemperature(°F)
Indoor Outdoor
dB WB dB WB
Cooling
Standardtemperature 80 67 95 —
Maximumtemperature 90 73 115 —
Minimumtemperature 67 57 14 —
Maximumhumidity 78% —
Heating
Standardtemperature 70 60 47 43
Maximumtemperature 80 67 75 65
Minimumtemperature 70 60 5 4
MSZ-GE-50 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
(1) INDOOR UNIT
Part Number Descriptions Applicable model
C13-103 BlueDiamondSensorExtensionCable-15Ft.
AllModels
DPLS1 DrainPanLevelSensor/ControlforindoorunitshutofftopreventDrainPanOverflow
MAC-2310Ft-E Anti-AllergyEnzymeFilter(qtyof2) GE24
MAC-308Ft-E PlatinumCatalystDeodorizingFilter GE06,09,12,15,18
MAC-333IF-E
SystemControlInterface-MA,Contactterminal,and
M-NETControlAdapter,Supplementalheatandhumidifier
adaptor
AllModels
MAC-408Ft-E Anti-AllergyEnzymeFilter(qtyof2) GE06,09,12,15,18
MCCH1 PortableCentralController(PCC)-controlsupto16RedLINKZones-requiresanMHK1oneachindoorunit
AllModels
MHK1 Wirelesswall-mountedremotecontroller(MRCH1)withasignalreceiver(MIFH1)andcable(MRC1)allinonekit
MoS1 OutdoorAirSensor-readsbothoutsidetemperatureandhumiditydisplayedonMRCH1andMCCH1ifinstalled
PAC-YT53CRAU SimpleMARemoteController(requiresMAC-333IF-EinterfaceforMSY/ZandMFZindoorunits)
PAR-31MAA
Wallmounted,hardwired,multi-functionalcontroller:used
specificallyforgrouping(upto16units),twinning,lead/lag,
and7dayprogrammableapplications
(requiresMAC-333IF-EinterfaceforMSY/ZandMFZindoor
units)
RCMKP1CBLockdownBracketforwireless,hand-held,remote
controllers
3-14. aCCeSSorieS
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-51© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
(1) INDOOR UNIT cont.
Part Number Descriptions Applicable model
SI30-115 Mini-Condensationpump-115voltapplication
AllModels
SI30-230 Mini-Condensationpump-230voltapplication
tAZ-MS303
3-PoleDisconnectSwitch30Amps600voltsratedfor
interuptingpowersupplyat/nearindoorunit-fits2X4utility
box
X87-721AdvancedBlueDiamondMini-Condensationpumpw/
Resevoir&Sensor-208/230voltapplication
MLS143812T-15
Diamondback
Linesets
1/4x3/8x15'/1/2"Twin-TubeInsulation
GE09,12
MLS143812T-30 1/4x3/8x30'/1/2"Twin-TubeInsulation
MLS143812T-50 1/4x3/8x50'/1/2"Twin-TubeInsulation
MLS143812T-65 1/4x3/8x65'/1/2"Twin-TubeInsulation
MLS141212T-15 1/4x1/2x15'/1/2"Twin-TubeInsulation
GE15,18
MLS141212T-30 1/4x1/2x30'/1/2"Twin-TubeInsulation
MLS141212T-50 1/4x1/2x50'/1/2"Twin-TubeInsulation
MLS141212T-65 1/4x1/2x65'/1/2"Twin-TubeInsulation
MLS141212T-100 1/4x1/2x100'/1/2"Twin-TubeInsulation
3-14. aCCeSSorieS
MSZ-GE-52 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
(1) INDOOR UNIT cont.
Part Number Descriptions Applicable model
MPLS385812T-10
Diamondback
Linesets
3/8x5/8x10'/1/2"Twin-TubeInsulation
GE24
MPLS385812T-15 3/8x5/8x15'/1/2"Twin-TubeInsulation
MPLS385812T-30 3/8x5/8x30'/1/2"Twin-TubeInsulation
MPLS385812T-50 3/8x5/8x50'/1/2"Twin-TubeInsulation
MPLS385812T-65 3/8x5/8x65'/1/2"Twin-TubeInsulation
MPLS385812T-100 3/8x5/8x100'/1/2"Twin-TubeInsulation
3-14. aCCeSSorieS
2013 M-Series - MSZ-GE Heat Pump Systems (October 2013) MSZ-GE-53© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.
3-14. aCCeSSorieS
(2) OUTDOOR UNIT
Part Number Descriptions Applicable model
CWMB1 4piece(1pair)condensingunitwallmountingbrackets-paintedsteel
AllModels
DSD-400P OutdoorUnit3-1/4inchMountingBase(Pair)-Plastic
MAC-640BH-U OutdoorUnitDrainPanHeaterusedduringdefrostcycle GE09,12,15
MAC-641BH-U OutdoorUnitDrainPanHeaterusedduringdefrostcycle GE18
MAC-642BH-U OutdoorUnitDrainPanHeaterusedduringdefrostcycle
GE24MAC-860dSOutdoordrainpansocket-Providespipeconnectiontoroute
condensateoutofdrainpan
MAC-886SG-EOutdoorairoutletguidefordirectingdischargeairawayfrom
otheroutdoorunit
MAC-889SGOutdoorairoutletguidefordirectingdischargeairawayfrom
otheroutdoorunitGE09,12,15,18,24
ULTRILITE1 CondensingUnitMountingPad16"x36"x3" AllModels
MSZ-GE-54 2013 M-Series - MSZ-GE Heat Pump Systems (October 2013)© 2013 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specification may be subject to change without notice.