m cast resin straight-through joint...underground water cable trays voltage level u 0 /u (u m) 0.6/1...
TRANSCRIPT
M7-M8
ScopeofdeliveryHydrolysisresistancePURtypeEGcast-resin,containingthecorrectvolumereadyformixingTransparentmouldsFillinginfunnelandairreleasefunnelWorkinginstructionPVCinsulationtapeProtectivegloves
NoteWithoutconnectors
TestsDINVDE0278part1and3DINVDE0278part393EN50393aswellasCENELECHD623(VDE0278part623)
Storageconditions/ShelflifeCastresinupto40months
•
•••••••••
•
ApplicationIndoorOutdoorUndergroundWaterCabletrays
VoltagelevelU0/U(Um)0.6/1(1.2)kV
••••••
Castresinstraight-throughjoint
CharacteristicsCompactdimensionsVisiblesplicepositionbeforecastingHighquality,transparent,shockproofplasticmouldsImmediatelyoperationalExtremely simple and fast fitting, savestimeandcostsResistanttochemicalagentsResistanttoalkalineearthsUV-resistantWatertightbothlongitudinallyandtransverselyHighelectricalinsulationvaluesHighmechanicalstrength
•••••••••••
H
L
D
D
L
H
Dimensions
UniversallysuitabletoconnectlowvoltageplasticinsulatedcablesorconductorsinsulatedwithPVC,PE,VPEandEPR.Suitableforcompressionconnectorsonaluminiumandcopperconductors
M
M0-M6
CatalogueLowVoltage2008 CatalogueLowVoltage2008 CatalogueLowVoltage2008 CatalogueLowVoltage2008
Cas
t-res
inte
chno
logy
CatalogueLowVoltage2009 CatalogueLowVoltage2009
67 www.cellpack.com
CatalogueLowVoltage2009 CatalogueLowVoltage2009 Straight-throughjoints
FortelecommunicationcableascreentransfertypeSVLisrequired.
Connectorsmustbeorderedseparately.Armouringtransferforarmouredcableonrequest.Straight-throughjointsforminingonrequest.
Controlcableandsignalcable
*Optionalaccessory:Screenstraight-throughconductorSVL/AccessoriesCompressionconnectors/ConnectingtechnologyUNIVERSALCLEANERNo.121/Accessories
M
TypeMax.
cable-Ømm
Lmm
Dmm
Hmm
Controlcableandsignalcable
Art.-No.
0.4mm² 0.6mm² 0.8mm² 0.75mm² 1.5mm²Numbertwistedpairs Numberofconductors
M0 15 185 32 37 6–20 6–10 6–6 16 8 124293*
M1 22 240 40 45 30–70 20–30 10–20 56 21 124294*
M2 30 265 45 50 100–150 40–70 30–40 114 56 124295*
M2.5 37 310 58 65 200–250 100–120 50–70 154 96 124296*
M3 42 355 70 80 300 150 100–120 200 133 124297*
Forenergycablesandconductors
Typemax.
Cable-Ømm
Lmm
Dmm
Hmm
Polymericcable Concentricconductor Armoured
Art.-No.
1x 2x 3x 4x 5x 3x 4x 3x 4xNominalcrosssectionperconductor
M0 15 185 32 37 25 10 6 6 2.5 124293*
M1 22 240 40 45 95 25 16 16 6 10/10 124294*
M2 30 265 45 50 185 35 25 16 25/25 16/16 16 16 124295*
M2.5 37 310 58 65 300 70 50 35 35/35 25/25 35 35 124296*
M3 42 355 70 80 400 95 70 50 50/50 50/25 50 50 124297*
M4 52 430 90 98 500 120 95 70 95/95 70/35 95 95 124298*
M5 62 550 110 120 240 185 150/150 120/70 120 120 124299*
M6 80 660 145 165 300 240 240/240 240/120 240 240 124300*
M7 80 900 150 190 300 124308*
M8 90 1,100 150 190 400 124309*
Particularyfortheeuropeanmarket
CatalogueLowVoltage2008 CatalogueLowVoltage2008
Cas
t-res
inte
chno
logy
CatalogueLowVoltage2008 CatalogueLowVoltage2008
68 www.cellpack.com
CatalogueLowVoltage2009 CatalogueLowVoltage2009 CatalogueLowVoltage2009 CatalogueLowVoltage2009Straight-throughjoints
M
TypeMax.
cable-Ømm
Lmm
Dmm
Hmm
Controlcableandsignalcable
Art.-No.
0.4mm² 0.6mm² 0.8mm² 0.75mm² 1.5mm²Numbertwistedpairs Numberofconductors
M0 15 185 32 37 6–20 6–10 6–6 16 8 124409*
M1 22 240 40 45 30–70 20–30 10–20 56 21 124410*
M2 30 265 45 50 100–150 40–70 30–40 114 56 124411*
M2.5 37 310 58 65 200–250 100–120 50–70 154 96 124412*
M3 42 355 70 80 300 150 100–120 200 133 124413*
TypeMax.
cable-Ømm
Lmm
Dmm
Hmm
Polymericcable Concentricconductor Armoured
Art.-No.
1x 2x 3x 4x 5x 3x 4x 3x 4xNominalcrosssectionperconductor
M0 15 185 32 37 25 10 6 6 2.5 124409*
M1 22 240 40 45 95 25 16 16 6 10/10 124410*
M2 30 265 45 50 185 35 25 16 25/25 16/16 16 16 124411*
M2.5 37 310 58 65 300 70 50 35 35/35 25/25 35 35 124412*
M3 42 355 70 80 400 95 70 50 50/50 50/25 50 50 124413*
M4 52 430 90 98 500 120 95 70 95/95 70/35 95 95 124414*
M5 62 550 110 120 240 185 150/150 120/70 120 120 124415*
M6 80 660 145 165 300 240 240/240 240/120 240 240 124416*
Particularlyfortheexportmarket
Forenergycablesandconductors
Controlcableandsignalcable
Connectorsmustbeorderedseparately.Armouringtransferforarmouredcableonrequest.Straight-throughjointsforminingonrequest.
FortelecommunicationcableascreentransfertypeSVLisrequired.
*Optionalaccessory:Screenstraight-throughconductorSVL/AccessoriesCompressionconnectors/ConnectingtechnologyUNIVERSALCLEANERNo.121/Accessories
CatalogueLowVoltage2008 CatalogueLowVoltage2008 CatalogueLowVoltage2008 CatalogueLowVoltage2008
Cas
t-res
inte
chno
logy
CatalogueLowVoltage2009 CatalogueLowVoltage2009
69 www.cellpack.com
CatalogueLowVoltage2009 CatalogueLowVoltage2009 Straight-throughjoints
ScopeofdeliveryTransparentmouldsSpacersCapHydrolysisresistancePURtypeEGcast-resin,containingthecorrectvolumereadyformixing.Packedinpracticalandeasy-to-usetwochamberbagsPVCinsulationtapeProtectiveglovesWorkinginstruction
NoteWithoutconnectors
TestsDINVDE0278part1and3DINVDE0278part393EN50393aswellasCENELECHD623(VDE0278part623)
Storageconditions/ShelflifeCastresinupto40months
••••
•••••••
•
Castresinstraight-throughjoint
CharacteristicsCompactdimensionsVisiblesplicepositionbeforecastingHighquality,transparent,shockproofplasticmouldsExtremely simple and fast fitting, savestimeandcostsLargeinsertionopeningforeasycastingResistanttochemicalagentsResistanttoalkalineearthsUV-resistantWatertightbothlongitudinallyandtransverselyHighelectricalinsulationvaluesHighmechanicalstrengthImmediatelyoperational
••••••••••••
ApplicationIndoorOutdoorUndergroundWaterCabletrays
VoltagelevelU0/U(Um)0.6/1(1.2)kV
••••••
H
L
D
Dimensions
UniversallysuitabletoconnectlowvoltageplasticinsulatedcablesorconductorsinsulatedwithPVC,PE,VPEandEPR.Suitableforcompressionconnectorsonaluminiumandcopperconductors.
M-Euroline
CatalogueLowVoltage2008 CatalogueLowVoltage2008
Cas
t-res
inte
chno
logy
CatalogueLowVoltage2008 CatalogueLowVoltage2008
70 www.cellpack.com
CatalogueLowVoltage2009 CatalogueLowVoltage2009 CatalogueLowVoltage2009 CatalogueLowVoltage2009Straight-throughjoints
*Optionalaccessory:Compressionconnectors/ConnectingtechnologyUNIVERSALCLEANERNo.121/Accessories
Armouringtransferforarmouredcableonrequest.Othercrosssectiononrequest.
Forenergycablesandconductors
Type Max.cable-Ømm
Lmm
Dmm
Hmm
Polymericcable Concentricconductor Armoured
Art.-No.
4x 5x 3x 4xNominalcrosssectionperconductormm²
M11 26 190 36 50 10 6 10/10 124209*
M12 34 260 47 63 25 16 25/25 124210*
M13S 43 310 55 68 35 25 35/35 124211*
M13 43 360 55 75 50 35 50/50 35 124212*
M14S 48 350 70 95 70 50 70/70 50 124213*
M14 48 400 70 95 95 95/95 70 124214*
M15 63 530 100 120 150 150/150 120 124215*
M16 81 700 125 160 240 240/120 240 124216*
Particularlyfortheexportmarket
Type Max.cable-Ømm
Lmm
Dmm
Hmm
Polymericcable Concentricconductor Armoured
Art.-No.
4x 5x 3x 4xNominalcrosssectionperconductormm²
M11 26 190 36 50 10 6 10/10 124169*
M12 34 260 47 63 25 16 25/25 124170*
M13S 43 310 55 68 35 25 35/35 124171*
M13 43 360 55 75 50 35 50/50 35 124172*
M14S 48 350 70 95 70 50 70/70 50 124173*
M14 48 400 70 95 95 70 95/95 70 124174*
M15 63 530 100 120 150 120 150/150 120 124175*
M16 81 700 125 160 240 185 240/120 240 124176*
Particularyfortheeuropeanmarket
CatalogueLowVoltage2008 CatalogueLowVoltage2008 CatalogueLowVoltage2008 CatalogueLowVoltage2008
Cas
t-res
inte
chno
logy
CatalogueLowVoltage2009 CatalogueLowVoltage2009
71 www.cellpack.com
CatalogueLowVoltage2009 CatalogueLowVoltage2009 Straight-throughjoints
*Optionalaccessory:UNIVERSALCLEANERNo.121/Accessories
TypeMax.
cable-Ømm
Lmm
Dmm
Hmm
Polymericcable Concentricconductor
Art.-Nr.
4x 5x 3x 4xNominalcrosssectionperconductormm²
M11V 26 190 36 50 1.5–6 1.5–6 1.5/1.5–6/6 131863*
M12V 34 260 47 63 10–16 10–16 10/10–16/16 131867*
M13SV 43 310 55 68 16–25 16/16–25/25 131866*
M13V 43 360 55 75 25–35 25/25–35/35 131864*
M14V 48 400 70 95 50–70 50/50–70/70 131865*
Forenergycablesandconductors
ScopeofdeliveryCapHydrolysisresistancePURtypeEGcast-resin,containingthecorrectvolumereadyformixing.Packedinpracticalandeasy-to-usetwochamberbagsTransparentmouldsSpacersWorkinginstructionPVCinsulationtapeProtectiveglovesScrewconnector
NoteWithconnectors
TestsDINVDE0278part1and3DINVDE0278part393EN50393aswellasCENELECHD623(VDE0278part623)
Storageconditions/ShelflifeCastresinupto40months
••
••••••••••
•
withscrewconnectorsCastresinstraight-throughjoint
CharacteristicsCompactdimensionsVisiblesplicepositionbeforecastingHighquality,transparent,shockproofplasticmouldsImmediatelyoperationalExtremely simple and fast fitting, savestimeandcostsLargeinsertionopeningforeasycastingResistanttochemicalagentsResistanttoalkalineearthsUV-resistantWatertightbothlongitudinallyandtransverselyHighelectricalinsulationvaluesHighmechanicalstrength
••••••••••••
ApplicationIndoorOutdoorUndergroundWaterCabletrays
VoltagelevelU0/U(Um)0.6/1(1.2)kV
••••••
H
L
D
Dimensions
UniversallysuitabletoconnectlowvoltageplasticinsulatedcablesorconductorsinsulatedwithPVC,PE,VPEandEPR.Suitableforaluminiumorcopperconductors
M…V-Euroline
CatalogueLowVoltage2008 CatalogueLowVoltage2008
Cas
t-res
inte
chno
logy
CatalogueLowVoltage2008 CatalogueLowVoltage2008
72 www.cellpack.com
CatalogueLowVoltage2009 CatalogueLowVoltage2009 CatalogueLowVoltage2009 CatalogueLowVoltage2009Straight-throughjoints
*Optionalaccessory:Compressionconnectors/ConnectingtechnologyUNIVERSALCLEANERNo.121/Accessories
Forenergycablesandconductors
ScopeofdeliverySealingfoamsHydrolysisresistancePURtypeEGcast-resin,containingthecorrectvolumereadyformixingMouldWorkinginstructionProtectiveglovesStrainrelief
NoteWithoutconnectors
TestsDINVDE0278part1and3DINVDE0278part393EN50393aswellasCENELECHD623(VDE0278part623)
Storageconditions/ShelflifeCastresinupto40months
••
••••••••
•
Castresinstraight-throughjoint
Type Max.cable-Ømm
Lmm
Dmm
Hmm
Polymericcable Concentricconductor
Art.-No.
3x 4x 3x 4xNominalcrosssectionperconductormm²
PV3 40 427 100 120 50–95 35–70 70/70 50/50 127705*
PVM5 48 642 116 135 95–150 95–150 150/150 120/120 127706*
PVS5 48 642 136 160 95–150 95–150 150/150 120/120 127708*
PVM6 58 850 137 185 185–300 185–240 240/120 185/185 127707*
CharacteristicsCompactdimensionsHighquality,shockproofplasticmouldsIntegratedstrainreliefImmediatelyoperationalExtremely simple and fast fitting, savestimeandcostsLargeinsertionopeningforeasycastingResistanttochemicalagentsResistanttoalkalineearthsUV-resistantWatertightbothlongitudinallyandtransverselyHighelectricalinsulationvaluesHighmechanicalstrength
••••••••••••
ApplicationIndoorOutdoorUndergroundWaterCabletrays
VoltagelevelU0/U(Um)0.6/1(1.2)kV
••••••
HD
L
Dimensions
UniversallysuitabletoconnectlowvoltageplasticinsulatedcablesorconductorsinsulatedwithPVC,PE,VPEandEPRandpaperinsulatedcables.Suitableforaluminiumandcopperconductors.
PV,PVM,PVS
CatalogueLowVoltage2008 CatalogueLowVoltage2008 CatalogueLowVoltage2008 CatalogueLowVoltage2008
Cas
t-res
inte
chno
logy
CatalogueLowVoltage2009 CatalogueLowVoltage2009
75 www.cellpack.com
CatalogueLowVoltage2009 CatalogueLowVoltage2009 Straight-throughjoints
Connectionandbranch-offbox
Scopeofdelivery286mlCastresinKGBranchboxwithdiaphragms5Springclampconnectors5pol.0.5-2.5mmWorkinginstructionCleaningtissueEmeryclothFunnel for vertical filling
NoteCast-resinKG286canbeorderedseparately to refill the box
TestsCorrespondstotheprotectionclassIP68
TeststandardEN50393,(VDE0278Part393),testmethodsandtestrequestsfordistributorcables-kitswithnominalvoltage0,6/1,0(1,2)kV
••••••••
•
•
Thenewconnectionandbranchingbox,combinestheadvantagesofatraditionalboxwiththewell-knownprofessionalcast-resintechnology.Complexconnectionsinaverysmallvolumecanbedonewiththisuniversalbox.Thesystemguaranteesanabsolutewaterproofsolution,excludingallcondensationrisks.
withclamps
Type Art.-No.
UniversalBoxKG 221122
CharacteristicsForconductorcrosssectionsof0.5-2.5mm²LongevityunderpermanenthumidityeffectBranchboxwithdiaphragmexecutionHigh flexibility due to again removable castingresinResistantagainstsaltwaterUV-resistantEnvironmentallysustainable
•••••••
ApplicationIndoorareawithmuchhumidityOutdoor
Voltagelevel230/440V
•••
UniversalBoxKG
CatalogueLowVoltage2008 CatalogueLowVoltage2008 CatalogueLowVoltage2008 CatalogueLowVoltage2008
Cas
t-res
inte
chno
logy
CatalogueLowVoltage2009 CatalogueLowVoltage2009
93 www.cellpack.com
CatalogueLowVoltage2009 CatalogueLowVoltage2009 Universalbox
www.cellpack.comCatalogue Low Voltage 2005 99
Cas
t-res
in te
chno
logy
Cast-resin branch joint T...VT-joint with branch connector
Universally suitable to connect low voltage plastic insu-lated cables or conductors insulated with PVC, PE, VPE and EPR (e.g. N(A)YY, NYM, TT) with or without con-centric conductor. Suitable for compression connectors on aluminium and copper conductors.
Voltage level• U0/U (Um) 0.6/1 (1.2) kV
Applications• Indoor• Outdoor• Underground• Water • Cable trays
Features• Large insertion opening for easy casting• High electrical insulation values• Watertight both longitudinally and transversely• High mechanical strength• Resistant to UV-radiation, alkaline earths and
chemical agents• Compact size• Standard resin storable for up to 40 months• High quality, transparent, shockproof plastic moulds• Visible splice position before casting• Extremely simple and fast fitting, saves time and
costs• Immediately operational
Tests• DIN VDE 0278 part 1 and 3• DIN VDE 0278 part 393• EN 50393 as well as CENELEC HD 623 (VDE 0278,
part 623)
Delivery• Transparent moulds• Hydrolysis resistant PUR type EG cast-resin, con-
taining the correct volume ready for mixing, in handy two chamber mixing bag
• Branch joints• Sealing tape• Gloves• Illustrated easy-to-follow mounting instructions
For energy cables and conductors
Type for cable Ø mm
plastic insulated cables
Cat. No.5x
max. cross section per conductor mm2
main cable branch cableT 1V 22 6 6 155202T 2V 30 16 16 155204T 21/2V 37 25 16 155207
Type Lmm
Bmm
Dmm
Hmm
T 1V 240 138 50 60T 2V 267 154 60 70T 21/2V 310 183 75 85
Dimensions
B
D
L
DH
• UNIVERSAL CLEANER No.121 page 188
Branch joints
100 www.cellpack.com Catalogue Low Voltage 2005
Cas
t-res
in te
chno
logy
Cast-resin branch joint Y
Universally suitable to connect low voltage plastic insulated cables or conductors insulated with PVC, PE, VPE and EPR (e.g. N(A)YY, NYM, TT) with or without concentric conductor. Suitable for compression connectors on alumi-nium and copper conductors.
Voltage level• U0/U (Um) 0.6/1 (1.2) kV
Applications• Indoor• Outdoor• Underground• Water• Cable trays
Features• Large insertion opening for easy casting• High electrical insulation values• Watertight both longitudinally and transversely• High mechanical strength• Resistant to UV-radiation, alkaline earths and chem-
ical agents• Compact size• Standard resin storable for up to 40 months• High quality, transparent, shockproof plastic moulds• Visible splice position before casting• Extremely simple and fast fitting, saves time and
costs• Immediately operational
Tests• DIN VDE 0278 part 1 and 3• DIN VDE 0278 part 393• EN 50393 as well as CENELEC HD 623 (VDE 0278,
part 623)
Note• For joint sizes Y 3 and exceeding, branch-off ring
connectors can be used (e.g. Branch-off ring connector HE 1/70/150)
• With the necessary accessories, joints type Y are suitable for paper-insulated cabels (only on request)
Delivery• Transparent moulds• Hydrolysis resistant PUR type EG cast-resin, con-
taining the correct volume ready for mixing, in handy two chamber mixing bag
• Filling in funnel• Air release funnel (except Y 00)• Closing stops• Sealing tape• Gloves• Illustrated easy-to-follow mounting instructions
Branch joints
www.cellpack.comCatalogue Low Voltage 2005 101
Cas
t-res
in te
chno
logy
Dimensions
Y 00–Y 2, Y 31/2, Y 5, Y 6
Y 3, Y 4, Y 41/2
Type Lmm
Bmm
Dmm
Hmm
Y 00 150 75 38 50Y 0 185 80 45 55Y 1 240 110 60 70Y 2 285 120 65 75Y 3 240 145 100 110Y 31/2 300 150 110 120Y 4 285 170 110 120Y 41/2 335 193 120 130Y 5 382 220 140 150Y 6 570 275 180 190
B
L
D15˚
DH
D
B
L
20˚
H
D
Branch joints
102 www.cellpack.com Catalogue Low Voltage 2005
Cas
t-res
in te
chno
logy
• Branch-off ring connector HE 1/70/150 page 138• Split bolt connector Cu FK page 152• UNIVERSAL CLEANER No.121 page 188
For energy cables and conductors
Typefor cable Ø mm
plastic insulated cables concentric conductor
Cat. No.5x 3x 4x 3x
max. cross section per conductor mm2
main cable
branch cable
main cable
branch cable
main cable
branch cable
main cable
branch cable
Y 00 23 23 2.5 2.5 – – – – 133841Y 0 17 17 – – 4 4 4/4 4/4 152932Y 1 22 22 – – 10 4 10/10 10/10 124730Y 2 37 33 – – 35 16 16/16 10/10 147533Y 3 42 37 – – 50 35 25/25 16/16 131123Y 31/2 54 38 – – 50 35 35/35 25/25 131118Y 4 53 37 – – 95 50 70/70 25/25 124763Y 41/2 56 42 – – 150 70 120/120 95/95 131119Y 5 62 52 – – 240 95 150/150 95/95 157645Y 6 90 80 – – 300 185 240/120 185/95 131126
Other cross sections on request
Y – designed for the European market
Y – designed for the Export marketFor energy cables and conductors
Typefor cable Ø mm
plastic insulated cables concentric conductor
Cat. No.5x 3x 4x 3x
max. cross section per conductor mm2
main cable
branch cable
main cable
branch cable
main cable
branch cable
main cable
branch cable
Y 00 23 23 2.5 2.5 – – – – 133122Y 0 17 17 – – 4 4 4/4 4/4 124747Y 1 22 22 – – 10 4 10/10 10/10 124744Y 2 37 33 – – 35 16 16/16 10/10 124745Y 3 42 37 – – 50 35 25/25 16/16 124746Y 31/2 54 38 – – 50 35 35/35 25/25 124749Y 4 53 37 – – 95 50 70/70 25/25 124748Y 41/2 56 42 – – 150 70 120/120 95/95 124750Y 5 62 52 – – 240 95 150/150 95/95 124751Y 6 90 80 – – 300 185 240/120 185/95 124752
Other cross sections on request
Branch joints
CharacteristicsConnectionareafullycoveredbythegelRe-accessableandoperationalimmediatelyHighquality,shockproofplasticmouldsFastandsimplemountingUnlimitedstorage
•••••
ApplicationIndoorForinterwiringinsideandoncablerunsOvergroundTemporaryandprovisionalinstallations
••••
ToconnectpolymericcablesN(A)YY,NYM,H05...crosssectionfrom1.5mm²to16mm²
Type
Polymericcable
Art.-No.1x 3x 4x 5x
Maincable Branchcable Maincable Branchcable Maincable Branchcable MaincableNominalcrosssectionperconductormm²
withoutconnectors
Easy2 2.5–50 16 2049003 1.5-6 1.5 1.5–6 1.5 1.5–6 2059704 6.0-16 2.5 6–16 2.5 6–16 205971
withconnectionblock
Easy3 1.5-6 1.5–6 1.5–6 2049014 6.0-16 6–16 6–16 204902
forconnectingandbranch-offallpolymericcablefrom1.5upto16mm²GeljointEasy
CatalogueLowVoltage2008 CatalogueLowVoltage2008
Gel
tech
nolo
gy
CatalogueLowVoltage2008 CatalogueLowVoltage2008
108 www.cellpack.com