lvk - noja power distribution kiosk... · 2019. 11. 6. · operating voltage rating 415 / 440 v ac...
TRANSCRIPT
®
LVK 415V AC - 38kA
LOW VOLTAGE DISTRIBUTION KIOSKPRODUCT GUIDE
Introduction
INTRODUCTION / OVERVIEW
1. Product Guide Low Voltage Distribution Kiosk
The NOJA series of Low Voltage Distribution Kiosk’s consists of 2 different enclosure sizes and 5 standard configurations of supplied equipment.
The Low Voltage Kiosk has been designed to be partially buried in ground or wall mounted in the same standard enclosure. Kiosk standard construction is 304 Grade Stainless Steel with powder coat. The exterior design was done with aesthetics in mind and so is suitable for installation in public areas.
The Kiosk’s features a sloping lid to prevent accumulation of debris and moisture. The Enclosures are weather, rodent and bird proof. The doors of the kiosk feature 3 point locking with a vandal proof / pad lockable handle. High positioning of top vents allow for excellent heat dissipation.
Slide out bottom covers allowing ease of cable installation and readily accessible lifting lugs are common across all kiosk design.
LOW VOLTAGE DISTRIBUTION KIOSK
Introduction 1.2.Product Guide Low Voltage Distribution Kiosk
This Kiosk can be used for the connection of two network circuits of 400 Amps and a 630 Amp fuse switch for use with a single large customer connection with large consumer mains. To enable this, the kiosk comes complete with bolt on connections on the bus bar for direct connection of customer’s cable.
Kiosk Type 2 can be used for the connection of up to three 160 Amp fuse switches for customer connection and up to 100 amp fuse switch and two network connections direct to the bus bar. The network connections are achieved by bolt on connections on the left and right hand sides of the kiosk.
LOW VOLTAGE DISTRIBUTION KIOSK (LVK1-2IFS)
LOW VOLTAGE DISTRIBUTION KIOSK (LVK2-3FSCC)
For all enquires telephone 13 12 53
TOTAL WEIGHT150KG
For all enquires telephone 13 12 53
ELECTRICITYDANGER
TOTAL WEIGHT150KG
For all enquires telephone 13 12 53
File:Plot Date:
REVISIONS
DrawnNo Description DateDrawn App. No Description Copyright NOJA PowerThis document remains the propertyof NOJA Power at all times.
App. Date
All dimensions in mm unlessotherwise stated
DO NOT SCALE
ScaleIssuedApprovedCheckedDrawn Original
Size A3Title
Drawing Number Sheet of
Revision
C
ENERGEX LV DISTRIBUTION CABINETITEM 2 GENERAL ARRANGEMENT
J7032-SC21877-00011 1
3NTS
CZGRHGRH21-12-11
0 FOR MANUFACTURE CZ GRH 21-12-111 REVISED AS PER CUSTOMER E-MAIL (B.B. 02-05-12) CZ SG 10-05-122 REVISED AS PER CUSTOMER E-MAIL (B.B. 11-05-12) CZ SG 16-05-123 DIMS ADDED TO SECTIONS, WEIGHT LABEL CORRECTED CZ SG 26-07-12
July 26, 2012 - 7:17amC:\Users\CHRIST~1\AppData\Local\Temp\AcPublish_4496\J7032-SC21877-0001 GA Item 2.dwg
Introduction 3. Product Guide Low Voltage Distribution Kiosk
The type 3 kiosk can be used to connect one network circuit to a 1000 Amp isolator and two 630 Amps fuse switches for customer connections. There are also three spare mounting positions available on this kiosk, one for an additional 1000 Amp network circuit and two more 630 Amp customer connections. Spare space in the panel allows for a service fuse connection.
Kiosk 4 features a Bus-Tie arrangement. This allows for a connection of four 630 Amp isolators with a 1000 Amp isolator mounted midway for use as a Bus-Tie. Having a midway mounted Bus-Tie allows for two 630 Amp network isolators installed on either side of the 1000 Amp Bus-Tie. Spare space in the panel allows for a service fuse connection.
LOW VOLTAGE DISTRIBUTION KIOSK (LVK4-4IBT)
LOW VOLTAGE DISTRIBUTION KIOSK (LVK3-I2FS)
TOTAL WEIGHT150KG
For all enquires telephone 13 12 53
ELECTRICITYDANGER
For all enquires telephone 13 12 53
Introduction 4.Product Guide Low Voltage Distribution Kiosk
(LVK3-I2FS) (LVK4-4IBT)
LOW VOLTAGE DISTRIBUTION KIOSK (LVK5-4I2FS)
The Type 5 Kiosk has the available space to connect four 630 Amp Isolator network connections and two 160 Amp fuse switches for customer connections. This allows spare space for an additional customer connection, alternator connection or auxiliary services fuse.
TOTAL WEIGHT150KG
For all enquires telephone 13 12 53
ELECTRICITY
Introduction
LOW VOLTAGE SWITCHGEAR
5. Product Guide Low Voltage Distribution Kiosk
Standard Switchgear supplied can be fitted with a range of DIN style fuses from DIN00 100 amp up to DIN3 630 amp to suit a wide range of customer loads.
Connections are made onto flags mounted on the base of the switch. These flags are capable of terminating 2x240 mm square cables.
Standard Switchgear supplied can be fitted with solid links to suit a wide range of customer specifications.
Connections are made onto flags mounted on the base of the switch. These flags are capable of terminating 2x240 mm square cables.
Introduction
MOUNTING OpTIONS / ACCESSORIES
6.
Kiosk’s can be Base or Wall mounted to suit a range of different installation options. When base mounting 1600mm Stainless Steel rag bolts are used to lessen risk of tipping or pulling over of the kiosk. A template for mounting is supplied.
The option for wall mounting is factory fitted Stainless Steel rails to rear of enclosure.Auxiliary Service Fuses can also be factory fitted for the supply to street lights, etc.
Product Guide Low Voltage Distribution Kiosk
Specification LVK1 – 2IFS LVK2 – 3FSCC LVK3 – I2FS LVK4 - 4IBT LVK5 – 4I2FS
Main Bus Current Rating 1000 AMp 1000 AMp 1000 AMp 1000 AMp 1000 AMp
Switch Fuse Size 630 AMp 160 AMp 630 AMp NA 160 AMp
Link Rating 400 AMp NA NA NA NA
Isolator Rating NA NA 1000 AMp 630 AMp 630 AMp
Bus Tie NA NA NA 1000 AMp NA
No of Links / Switch Fuse / Isolator
2 / 1 / NA 3 / NA / NA / 2 x Direct Connections
NA / 2 / 1 / 3 x Spare Connections
NA / NA / 4 / 1 x Generator Connection
NA / 2 / 4 / 1 x Generator Connection
Short Circuit Withstand Rating (1s)
31.5 kA 31.5 kA 31.5 kA 31.5 kA 31.5 kA
Operating Voltage Rating 415 / 440 V AC 415 / 440 V AC 415 / 440 V AC 415 / 440 V AC 415 / 440 V AC
®
NOJA-595-01
NOJA power® is a registered trademarks of NOJA power Switchgear pty Ltd. This document is copyright and is intended for users and distributors of NOJA power Switchgear product. It contains information that is the intellectual property of NOJA power Switchgear and the document, or any part thereof, should not be copied or reproduced in any form without written permission from NOJA power Switchgear.NOJA power Switchgear applies a policy of continued fundamental research and development and reserves the right to change designs and specifications of this product without notice. NOJA power Switchgear does not accept any responsibility for loss or damage incurred by anyone as a result of acting or refraining from action based on information in this product Guide.
Scan to view NOJA Power website
NOJA POWER AUSTRALIACORPORATE OffICE & fACTORy
NOJA Power Switchgear Pty Ltd 16 Archimedes place, Murarrie Brisbane Qld 4172, Australia
phone: +61 (7) 3907 8777 Fax: +61 (7) 3399 6777 Email: [email protected] Web: www.nojapower.com.au
NOJA POWER UKSALES OffICE
NOJA Power Limited4 Stalyhill Drive, StalybridgeCheshire SK 15 2TRUnited Kingdom
phone: +44 (01865) 58 9499Fax: +44 (01865) 58 9400 Email: [email protected] Web: www.nojapower.co.uk
NOJA POWER CHILESALES OffICE
NOJA Power SpAAv 11 de septiembre 1881, Of 1415Providencia, SantiagoChile
phone: +56 (2) 8979649 Email: [email protected]: www.nojapower.c l
NOJA POWER BRAZILOffICE & fACTORy
NOJA Power do Brasil LtdaAvenida pierre Simon de Laplace, 764Techno park – Campinas – SpCEp 13069-301, Brasil
phone: +55 (19) 3283 0041Fax: +55 (19) 3283 0041Email: [email protected]: www.nojapower.com.br