Head Office/Factory :Jl. Gatot Subroto Km 7,8 Kel Pasir Jaya, Kec. Jati Uwung, Tangerang 15135-IndonesiaPhone : (62-21) 5922404, 5928066 (Hunting) Fax. : (62-21) 59301979, 5922576, 5901469

c Copyright Sumi Indo Kabel 2009

All rights reserved. This catalogue is the copyright work of PT. Sumi Indo Kabel Tbk. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,in any form or by means, electronic, mechanical, photocopying, recording or otherwise, without prior permission of PT. Sumi Indo Kabel.

All information contained in this catalogue is believed to be accurate at the time issue. PT. Sumi Indo Kabel reserve the right to change information or specification at any timein the light of technical developments or revisions.

Issue : 3 Date: June 2009

Page 3: LV2009

Section 1 - Contents & Information

Low Voltage Catalogue Index Page Number

SECTION 1 - Contents & InformationIndex Page 11

Company Profile of PT. SUMI INDO KABEL Tbk 2

Cable Specification 3

SECTION 2 - PVC Insulated CablesUnarmoured Cables

450/750 Volts PVC Insulated Cables (Cu/PVC, NYA) 5

450/750 Volts PVC Insulated Cables (Flexible Cu/PVC, NYAF) 6

300/500 Volts PVC Insulated and PVC Sheathed Cables (PVC/PVC, NYM) 8

300/500 Volts PVC Insulated and PVC Sheathed Cables (Flexible PVC/PVC, NYMHY) 10

450/750 Volts PVC Insulated and PVC Sheathed Cables (Flexible PVC/PVC, NYYHY) 11

600/1000 Volts PVC Insulated and PVC Sheathed Cables (PVC/PVC, NYY) 18

600/1000 Volts PVC Insulated, Copper Tape Shielded and PVC Sheathed Cables (PVC/PVC-S, NYSY) 30

Armoured Cables

600/1000 Volts PVC Insulated, Steel Wire Armoured and PVC Sheathed Cables (PVC/SWA/PVC, NYRY) 35

600/1000 Volts PVC Insulated, Flat Steel Wire Armoured and PVC Sheathed Cables (PVC/FSWA/PVC, NYFGbY) 41

600/1000 Volts PVC Insulated, Double Steel Tape Armoured and PVC Sheathed Cables (PVC/DSTA/PVC, NYBY) 46

SECTION 3 - XLPE Insulated CablesUnarmoured Cables

600/1000 Volts XLPE Insulated and PVC Sheathed Cables (XLPE/PVC, N2XY) 52

600/1000 Volts XLPE Insulated, Copper Tape Shielded and PVC Sheathed Cables (XLPE/PVC-S, N2XSY) 62

Armoured Cables

600/1000 Volts XLPE Insulated, Steel Wire Armoured and PVC Sheathed Cables (XLPE/SWA/PVC, N2XRY) 67

600/1000 Volts XLPE Insulated, Flat Steel Wire Armoured and PVC Sheathed Cables (XLPE/FSWA/PVC, N2XFGbY) 73

600/1000 Volts XLPE Insulated, Double Steel Tape Armoured and PVC Sheathed Cables (XLPE/DSTA/PVC, N2XBY) 78

SECTION 4 - General InformationCurrent Carrying Capacity for XLPE Insulated cable (single core) 83

Current Carrying Capacity for XLPE Insulated cable (multicore) 84

Current Carrying Capacity for PVC Insulated cable (single core) 85

Current Carrying Capacity for PVC Insulated cable (multicore) 86

Correction factor of Curent carrying capacity 87Cable arrangement for Installation purpose 88Explanation of Flame Retardant / Fire Resistant Characteristic 91

Page - 1

Page 4: LV2009

Section 1 - Contents & Information

Page - 2

1

Company Profile of PT. Sumi Indo Kabel Tbk

The Company was established on July 23, 1981 with its Head Officeand Factory located in Tangerang, Banten. The Company is engaged in the manufacturing of Power Cable, Telecommunication Cable &Fiber Optic, and Copper Wire.

The Company was listed in the Jakarta and Surabaya Stock Exchangesin 1990. The Company became Foreign Capital Investment (PMA)in 1994, with the participation of Sumitomo Electric Industries, Ltd.,Japan, one of the biggest in cable and wire industries in the world. Thename of Company became PT Sumi Indo Kabel Tbk. since 1999.

The Company received official recognition of its quality managementsystem standard from SGS, certification ISO 9001 : 2000 for its PowerCable & Control Cable, Telephone Cable & Fiber Optic Cable, andCopper Wire Rod in 2002. This was the first recognition in Indonesiafor Electric Cable and Wire industries.

Page 5: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

450/750 V PVC INSULATED WIRE (Cu/PVC)acc. to IEC 60227

Copper Conductor (Solid) PVC Insulation

Copper Conductor (Stranded) PVC Insulation

Colour of Insulation : Red, White, Black, Green, Brown, Blue, Yellow, Green-yellow

450/750 V PVC INSULATED WIRE (Cu/PVC Flexible)acc. to IEC 60227

Copper Conductor (Flexible) PVC Insulation

Colour of Insulation : Red, White, Black, Green, Brown, Blue, Yellow, Green-yellow

Page - 4

Note : Special application upon request* Available product in accordance to : SPLN or other requirement.* Tin coated Copper conductor.

Page 6: LV2009

Section 1 - Contents & Information

1 Scope

2 Conductor

The conductor shall be solid, circular stranded or compacted stranded.

3 Insulation

4 Identification of cores

Number of core Identification of coresSingle core Black (Natural for XLPE insulated)Two cores Red, BlackThree cores Red, Yellow, BlueFour cores Red, Yellow, Blue, BlackFive core or more Black insulation with white numbered code.

5 Cabling and filling

6 Metallic Shielding (if required)The metallic shielding shall consist of either one or more Copper tapes or a concentric layer of copper wires.

7 Inner sheath (armour cable only).

8 Metallic armour

9 Outer sheath

The conductor shall be formed from plain annealed copper or aluminium complying with IEC 60228,ASTM B3 and B8.

The insulation shall be cross-linked polyethylene (XLPE) or Polivinyl chloride (PVC) in accordanceto IEC 60502-1.

The outer sheath shall consist of a thermoplastic compound such as polyvinyl chloride (PVC),polyethylene (PE), halogen free (LSOH), etc in accordance with IEC 60502-1.

Page - 3

The cores of all cables shall be identified by color or numbered printed on the surface of insulation inaccordance with the following sequence or other sequence.

The multi cores shall be laid up together with suitable filler to give the completed cable asubstantially circular cross section and bound with suitable binder tape.

The inner sheath shall consist of extruded thermoplastic compound such as :polyvinyl chloride(PVC), polyethylene (PE),halogen free (LSOH), etc in accordance to IEC 60502-1.

The metallic armour shall consist of single layer of round galvanized steel wire or flat galvanized steel wire and steel tape or double layer of galvanized steel tapes in accordance to IEC 60502-1.The armour of single core cables shall consist of single layer of aluminium wire or double layers ofaluminium tape as non magnetic material.

Cable Specification

These specification apply to material and constructions of cross-linked thermosetting polyethylene(XLPE) or Polivinyl chloride (PVC) insulated wire and cables for rated voltages 0.3/0.5 kV up to0.6/1(1.2) kV accordance to IEC 60502-1, Indonesia Electric Power Company (SPLN)

Page 7: LV2009

Section 2 - PVC Insulated CablesUnarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 450/750 V Insulation : PVC Compound type C Operating Temperature Colour Ident. : Red, White, Black, Green, Maximum 70°C

Blue, Yellow, Green-yellow

1.5 1 / 1.38 1.38 0.7 3.0 22 12.1 0.011 2500

1.5 7 / 0.52 1.56 0.7 3.5 23 12.1 0.010 2500

2.5 1 / 1.78 1.78 0.8 4.0 33 7.41 0.010 2500

2.5 7 / 0.67 2.01 0.8 4.0 35 7.41 0.009 2500

4 1 / 2.26 2.26 0.8 4.5 49 4.61 0.0085 2500

4 7 / 0.85 2.55 0.8 4.5 52 4.61 0.0077 2500

6 1 / 2.77 2.77 0.8 5.0 69 3.08 0.0070 2500

6 7 / 1.04 3.12 0.8 5.0 72 3.08 0.0065 2500

10 1 / 3.57 3.57 1.0 6.0 113 1.83 0.0070 2500

10 7 / 1.35 4.05 1.0 6.5 119 1.83 0.0065 2500

16 7 / 1.70 5.10 1.0 7.5 179 1.15 0.0050 2500

25 7 / 2.13 6.39 1.2 9.0 277 0.727 0.0050 2500

35 7 / 2.52 7.56 1.2 10.5 377 0.524 0.0040 2500

50 19 / 1.83 9.15 1.4 12.5 530 0.387 0.0045 2500

70 19 / 2.17 10.85 1.4 14.0 727 0.268 0.0035 2500

95 19 / 2.52 12.60 1.6 16.5 985 0.193 0.0035 2500

120 37 / 2.03 14.21 1.6 18.0 1218 0.153 0.0032 2500

150 37 / 2.27 15.89 1.8 20.0 1522 0.124 0.0032 2500

185 37 / 2.52 17.64 2.0 22.0 1873 0.0991 0.0032 2500

240 61 / 2.26 20.34 2.2 25.5 2465 0.0754 0.0032 2500

300 61 / 2.52 22.68 2.4 28.0 3055 0.0601 0.0030 2500

400 61 / 2.86 25.74 2.6 31.5 3927 0.0470 0.0028 2500

Page - 5

V/5 min

Maximum AC

Test

Voltage

M.km

Thickness

Nominal

Resistance Resistance

wire

Conductor

of

Nominal No./

Diameter

Minimum

Insulation

Cross-

Diameter

of wire

(approx.)

Conductorsection Insulation

Weight

Nominal

Overall

/kmkg/kmmm²

(Approx.)(Approx.)

No./mm

area (approx.)

mmmm mm

450/750 V PVC INSULATED WIRECU/PVC (IEC 60227)

Conductor

at 70°Cat 20°C

of Diameter of

Page 8: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 5) Uo/U - 450/750 V Insulation : PVC Compound type C Operating Temperature Colour Ident. : Red, White, Black, Green, Maximum 70°C

Blue, Yellow, Green-yellow

1.5 1.58 0.7 3.5 22 13.30 0.010 2500

2.5 0.26 2.04 0.8 4.0 34 7.98 0.009 2500

4 0.31 2.59 0.8 4.5 50 4.95 0.007 2500

6 0.31 3.46 0.8 5.5 75 3.30 0.006 2500

10 0.41 4.62 1.0 7.0 130 1.91 0.0056 2500

16 0.41 5.66 1.0 8.0 186 1.21 0.0046 2500

25 0.41 7.06 1.2 10.0 286 0.78 0.0044 2500

35 0.41 8.43 1.2 11.0 395 0.554 0.0038 2500

50 0.41 10.07 1.4 13.5 550 0.386 0.0037 2500

70 0.51 11.97 1.4 15.0 760 0.272 0.0032 2500

95 0.51 13.73 1.6 17.5 1008 0.206 0.0032 2500

120 0.51 15.53 1.6 19.5 1270 0.161 0.0029 2500

150 0.51 17.56 1.8 22.0 1605 0.129 0.0029 2500

185 0.51 19.16 2.0 24.0 1914 0.106 0.0029 2500

240 0.51 22.0 2.2 27.0 2491 0.0801 0.0028 2500

Page - 6

Maximum MinimumNominal Nominal

Thickness Overall

section Conductor

Nominal Diameter Insulation

Cross- of of Diameter of Resistance Resistance

Weight Conductor

0.26

at 70°C

area (Approx.) (Approx.)(approx.)

mm mm kg/km /kmmm² mm

(approx.)

Insulation wire at 20°C

mm V/5 minM.km

Conductor AC

Maximum Test

Diameter Voltage

of wire

450/750 V PVC INSULATED WIRECU/PVC-Flexible (IEC 60227)

Page 9: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

300/500 V PVC INSULATED AND PVC SHEATHED CABLESPVC/PVC (NYM) - IEC 60227 , SPLN 42-2

Conductor PVC Inner coveringPVC Insulation PVC Sheath

300/500 V PVC INSULATED AND PVC SHEATHED CABLESPVC/PVC Flexible (NYMHY) - IEC 60227 , SPLN 42-2

ConductorPVC Insulation PVC Sheath

450/750 V PVC INSULATED AND PVC SHEATHED CABLESPVC/PVC Flexible (IEC 60227, SPLN 42-6-3)

Tape (manufacturer's option)Conductor PVC Sheath

PVC InsulationFiller (Polyprophylene yarn,or extruded filler up to request)

Page - 7

Page 10: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 and 2) Uo/U - 300/500 V Insulation : PVC Compound Operating Temperature Inner covering : PVC Compound Maximum 70°C Sheath : PVC Compound type ST2 Colour Ident. : Insulation : Two cores - Red,Black

Three cores - Red,Yellow, Blue Sheath - White

TWO AND THREE CORES

No.

of

Core

-

1.5 1 / 1.38 1.38 0.7 0.4 1.2 9.5 129 12.1

7 / 0.52 1.56 0.7 0.4 1.2 10.0 138 12.1

2.5 1 / 1.78 1.78 0.8 0.4 1.2 11.0 173 7.41

7 / 0.67 2.01 0.8 0.4 1.2 11.0 184 7.41

4 1 / 2.26 2.26 0.8 0.4 1.2 12.0 222 4.61

2 7 / 0.85 2.55 0.8 0.4 1.2 12.5 239 4.61

6 1 / 2.77 2.77 0.8 0.4 1.2 13.0 294 3.08

7 / 1.04 3.12 0.8 0.4 1.2 14.0 313 3.08

10 1 / 3.57 3.57 1.0 0.6 1.4 16.0 453 1.83

7 / 1.35 4.05 1.0 0.6 1.4 17.0 492 1.83

16 7 / 1.70 5.10 1.0 0.6 1.4 19.0 668 1.15

25 7 / 2.13 6.39 1.2 0.8 1.4 23.0 998 0.727

35 7 / 2.52 7.56 1.2 1.0 1.6 26.0 1336 0.524

1.5 1 / 1.38 1.38 0.7 0.4 1.2 10.0 150 12.1

7 / 0.52 1.56 0.7 0.4 1.2 10.5 159 12.1

2.5 1 / 1.78 1.78 0.8 0.4 1.2 11.5 205 7.41

7 / 0.67 2.01 0.8 0.4 1.2 12.0 216 7.41

4 1 / 2.26 2.26 0.8 0.4 1.2 12.5 266 4.61

3 7 / 0.85 2.55 0.8 0.4 1.2 13.0 286 4.61

6 1 / 2.77 2.77 0.8 0.4 1.4 14.0 357 3.08

7 / 1.04 3.12 0.8 0.4 1.4 14.5 381 3.08

10 1 / 3.57 3.57 1.0 0.6 1.4 17.0 557 1.83

7 / 1.35 4.05 1.0 0.6 1.4 18.0 600 1.83

16 7 / 1.70 5.10 1.0 0.8 1.4 20.5 849 1.15

25 7 / 2.13 6.39 1.2 0.8 1.6 24.5 1270 0.727

35 7 / 2.52 7.56 1.2 1.0 1.6 27.5 1679 0.524

Conductor Nominal Nominal

at 20°C

Conductor

/km

Resistance

Thickness

Sheath

Weightdiameter

cable cable

Maximum

Nominal No./ Diameter Thickness

Cross- Diameter of of

section

Overall

of of

No./mm

(approx.) (approx.)

mm kg/kmmm

area

300/500 V PVC INSULATED AND PVC SHEATHED CABLESPVC/PVC (NYM) - IEC 60227 , SPLN 42-2

of wire Conductor Insulation

(approx.)

of

mm²

Thickness

of Inner

covering

(approx.)

mm mm

(approx.)

mm

Page - 8

Page 11: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 and 2) Uo/U - 300/500 V Insulation : PVC Compound Operating Temperature Inner covering : PVC Compound Maximum 70°C Sheath : PVC Compound type ST2 Colour Ident. : Insulation : Four core - Red,Yellow, Blue, Black

Five core - Black with numbering code Sheath - White

FOUR AND FIVE CORES

No.

of

Core

-

1.5 1 / 1.38 1.38 0.7 0.4 1.2 11.0 177 12.1

7 / 0.52 1.56 0.7 0.4 1.2 11.5 189 12.1

2.5 1 / 1.78 1.78 0.8 0.4 1.2 12.5 247 7.41

7 / 0.67 2.01 0.8 0.4 1.2 13.0 262 7.41

4 1 / 2.26 2.26 0.8 0.4 1.4 14.0 340 4.61

4 7 / 0.85 2.55 0.8 0.4 1.4 14.5 361 4.61

6 1 / 2.77 2.77 0.8 0.4 1.4 15.5 456 3.08

7 / 1.04 3.12 0.8 0.4 1.4 16.0 482 3.08

10 1 / 3.57 3.57 1.0 0.6 1.4 18.5 690 1.83

7 / 1.35 4.05 1.0 0.6 1.4 19.5 742 1.83

16 7 / 1.70 5.10 1.0 0.8 1.4 22.5 1059 1.15

25 7 / 2.13 6.39 1.2 1.0 1.6 27.5 1616 0.727

35 7 / 2.52 7.56 1.2 1.0 1.6 30.0 2107 0.524

1.5 1 / 1.38 1.38 0.7 0.4 1.2 11.5 210 12.1

7 / 0.52 1.56 0.7 0.4 1.2 12.0 223 12.1

2.5 1 / 1.78 1.78 0.8 0.4 1.2 13.5 293 7.41

7 / 0.67 2.01 0.8 0.4 1.2 14.0 313 7.41

4 1 / 2.26 2.26 0.8 0.6 1.4 15.5 424 4.61

5 7 / 0.85 2.55 0.8 0.6 1.4 16.5 452 4.61

6 1 / 2.77 2.77 0.8 0.6 1.4 17.0 548 3.08

7 / 1.04 3.12 0.8 0.6 1.4 17.5 579 3.08

10 1 / 3.57 3.57 1.0 0.6 1.4 20.0 839 1.83

7 / 1.35 4.05 1.0 0.6 1.4 21.5 898 1.83

16 7 / 1.70 5.10 1.0 0.8 1.6 25.0 1310 1.15

25 7 / 2.13 6.39 1.2 1.0 1.6 30.0 1969 0.727

35 7 / 2.52 7.56 1.2 1.2 1.6 33.5 2617 0.524

300/500 V PVC INSULATED AND PVC SHEATHED CABLES

Maximum

PVC/PVC (NYM) - IEC 60227 , SPLN 42-2

Nominal No./ Diameter Thickness

Conductor Nominal Nominal Overall

of Inner of of of Resistance

Thickness Thickness diameter Weight

cablesection of wire Conductor Insulation

Conductor

Cross- Diameter of of

at 20°C

area (approx.) (approx.) (approx.) (approx.) (approx.)

covering Sheath cable

mm kg/kmmm² No./mm mm mm

Page - 9

/kmmm mm

Page 12: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 5) Uo/U - 300/500 V

Insulation : PVC Compound type D Operating Temperature

Sheath : PVC Compound type ST5 Maximum 70°C

Colour Ident. : Insulation - Red,Black: Two core - Red,Black

Three core - Red,Yellow, Blue

Four core - Red,Yellow, Blue, Black

Five core - Black with numbering code

Sheath - White

Number

of

Core

-

0.75 1.13 7.0 64

2 1 0.21 1.31 7.5 74

1.5 1.58 8.5 98 13.3

2.5 0.26 2.04 10.0 145 7.98

0.75 1.13 7.5 75

3 1 0.21 1.31 7.5 87

1.5 1.58 9.0 121 13.3

2.5 0.26 2.04 10.5 180 7.98

0.75 1.13 8.0 90

4 1 0.21 1.31 8.5 108

1.5 1.58 10.0 150 13.3

2.5 0.26 2.04 11.5 219 7.98

0.75 1.13 9.0 111

5 1 0.21 1.31 9.5 129

1.5 1.58 11.0 182 13.3

2.5 0.26 2.04 13.0 266 7.98

Conductor Nominal Nominal Overall Maximum

Nominal Maximum Diameter Thickness Thickness diameter Weight Conductor

of ResistanceCross- Diameter of of

section of wire Conductor Insulation

of of

(approx.) (approx.)

Sheath cable cable at 20°C

(approx.)

mm² mm mm mm mm mm kg/km

area (approx.)

0.6 0.8

0.26 0.7 0.8

/km

0.6 0.8

0.26 0.7 0.9

0.8 1.0

0.21 0.6 0.8

0.6 0.9

0.26 0.7 1.0

0.8 1.1

0.21 0.6 0.8

0.26 0.7 1.1

0.8 1.1

0.21 0.6 0.9

0.21

300/500 V PVC INSULATED AND PVC SHEATHED CABLESPVC/PVC Flexible (IEC 60227, SPLN 42-6-2)

Page - 10

0.8 1.2

0.80.6

0.6 0.9

Page 13: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 5) Uo/U - 450/750 V Insulation : PVC Compound type D Operating Temperature Filler : Suitable material Maximum 70°C Sheath : PVC Compound type ST5 Colour Ident. : Insulation - Red,Black

Sheath - Black

TWO CORES

1.5 1.58 1.8 10.5 126 13.3

2.5 0.26 2.04 1.8 12.0 166 7.98

4 0.31 2.59 1.8 14.0 230 4.95

6 0.31 3.46 1.8 15.5 297 3.30

10 0.41 4.62 1.8 18.0 422 1.91

16 0.41 5.66 1.8 20.0 562 1.21

25 0.41 7.06 1.8 23.5 809 0.780

35 0.41 8.43 1.8 26.0 1061 0.554

50 0.41 10.07 1.8 30.5 1451 0.386

70 0.51 11.97 1.9 34.5 1949 0.272

95 0.51 13.73 2.0 39.0 2546 0.206

120 0.51 15.53 2.1 43.0 3160 0.161

Conductor

Maximum

Diameter

kg/km

1.6

450/750 V PVC INSULATED AND PVC SHEATHED CABLESPVC/PVC Flexible (IEC 60227, SPLN 42-6-3)

0.26

mm mm mm

(approx.) (approx.)

of

Insulation Sheath

Thickness

area (approx.)(approx.)

Nominal Nominal

Conductor

/km

1.4

1.4

1.6

MaximumOverall

at 20°C

diameter

Resistance

cable

of

WeightThickness

of

mm² mmmm

section Conductor

Nominal Diameter

Cross- of

of wire

of

cable

0.7

0.8

1.0

1.0

1.0

1.0

1.2

1.2

Page - 11

Page 14: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 5) Uo/U - 450/750 V Insulation : PVC Compound type D Operating Temperature Filler : Suitable material Maximum 70°C Sheath : PVC Compound type ST5 Colour Ident. : Insulation - Red,Yellow , Blue

Sheath - Black

THREE CORES

1.5 1.58 1.8 11.0 153 13.3

2.5 0.26 2.04 1.8 12.5 204 7.98

4 0.31 2.59 1.8 14.5 287 4.95

6 0.31 3.46 1.8 16.5 380 3.30

10 0.41 4.62 1.8 19.0 552 1.91

16 0.41 5.66 1.8 21.0 744 1.21

25 0.41 7.06 1.8 25.0 1085 0.780

35 0.41 8.43 1.8 28.0 1443 0.554

50 0.41 10.07 1.8 32.5 1986 0.386

70 0.51 11.97 2.0 37.0 2702 0.272

95 0.51 13.73 2.1 42.0 3542 0.206

120 0.51 15.53 2.2 46.0 4408 0.161

(approx.)area (approx.) (approx.) (approx.)

at 20°Csection of wire Conductor Insulation Sheath cable cable

of ResistanceofCross- Diameter of of of

Conductor Nominal Nominal

Maximum Diameter Thickness Thickness diameter Weight

450/750 V PVC INSULATED AND PVC SHEATHED CABLESPVC/PVC Flexible (IEC 60227, SPLN 42-6-3)

Maximum

mm² mm mm mm mm mm kg/km

ConductorNominal

1.0

1.0

1.0

1.2

Overall

/km

0.26

0.8

1.0

0.7

1.6

1.2

1.4

1.4

1.6

Page - 12

Page 15: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 5) Uo/U - 450/750 V Insulation : PVC Compound type D Operating Temperature Filler : Suitable material Maximum 70°C Sheath : PVC Compound type ST5 Colour Ident. : Insulation - Red,Yellow , Blue , Black

Sheath - Black

FOUR CORES

1.5 1.58 1.8 12.0 181 13.3

2.5 0.26 2.04 1.8 13.5 247 7.98

4 0.31 2.59 1.8 16.0 353 4.95

6 0.31 3.46 1.8 18.0 471 3.30

10 0.41 4.62 1.8 20.5 696 1.91

16 0.41 5.66 1.8 23.5 942 1.21

25 0.41 7.06 1.8 27.5 1390 0.780

35 0.41 8.43 1.8 31.0 1856 0.554

50 0.41 10.07 1.9 36.0 2579 0.386

70 0.51 11.97 2.1 41.0 3517 0.272

95 0.51 13.73 2.2 47.0 4610 0.206

120 0.51 15.53 2.4 51.5 5769 0.161

Conductor Nominal Nominal Overall

450/750 V PVC INSULATED AND PVC SHEATHED CABLESPVC/PVC Flexible (IEC 60227, SPLN 42-6-3)

Maximum

Nominal Maximum Diameter Thickness Thickness diameter Weight Conductor

Cross- Diameter of of of of of Resistance

cable at 20°Csection of wire Conductor Insulation

area (approx.) (approx.) (approx.)

Sheath cable

1.0

1.2

(approx.)

mm² mm mm mm mm mm kg/km /km

0.26

0.8

1.0

0.7

1.2

1.4

1.0

1.0

1.4

1.6

1.6

Page - 13

Page 16: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 5) Uo/U - 450/750 V Insulation : PVC Compound type D Operating Temperature Filler : Suitable material Maximum 70°C Sheath : PVC Compound type ST5 Colour Ident. : Insulation - Black with numbering code

Sheath - Black

FIVE CORES

1.5 1.58 1.8 13.0 215 13.3

2.5 0.26 2.04 1.8 14.5 290 7.98

4 0.31 2.59 1.8 17.0 425 4.95

6 0.31 3.46 1.8 19.5 567 3.30

10 0.41 4.62 1.8 22.5 847 1.91

16 0.41 5.66 1.8 25.5 1154 1.21

25 0.41 7.06 1.8 30.5 1703 0.780

35 0.41 8.43 1.9 34.0 2297 0.554

50 0.41 10.07 2.0 40.0 3200 0.386

Conductor Nominal Nominal Overall

450/750 V PVC INSULATED AND PVC SHEATHED CABLESPVC/PVC Flexible (IEC 60227, SPLN 42-6-3)

Maximum

Nominal Maximum Diameter Thickness Thickness diameter Weight Conductor

of ResistanceCross- Diameter of of

section of wire Conductor Insulation

of of

(approx.) (approx.)

Sheath cable cable at 20°C

(approx.)

mm² mm mm mm mm mm kg/km

area (approx.)

/km

0.26

1.0

1.0

1.2

0.7

Page - 14

0.8

1.0

1.2

1.4

1.0

Page 17: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 5) Uo/U - 450/750 V Insulation : PVC Compound type D Operating Temperature Filler : Suitable material Maximum 70°C Sheath : PVC Compound type ST5 Colour Ident. : Insulation - Black with numbering code

Sheath - Black

CONTROL CABLE : 1.5 mm²

6 1.58 1.8 14.0 240 13.3

7 0.26 1.58 1.8 14.0 258 13.3

8 0.26 1.58 1.8 15.0 295 13.3

9 0.26 1.58 1.8 16.0 326 13.3

10 0.26 1.58 1.8 17.0 360 13.3

12 0.26 1.58 1.8 17.5 408 13.3

14 0.26 1.58 1.8 18.5 458 13.3

15 0.26 1.58 1.8 19.0 489 13.3

16 0.26 1.58 1.8 19.0 514 13.3

18 0.26 1.58 1.8 20.0 562 13.3

19 0.26 1.58 1.8 20.0 580 13.3

20 0.26 1.58 1.8 21.0 614 13.3

24 0.26 1.58 1.8 23.5 725 13.3

30 0.26 1.58 1.8 24.5 868 13.3

32 0.26 1.58 1.8 25.0 921 13.3

37 0.26 1.58 1.8 26.5 1034 13.3

40 0.26 1.58 1.8 27.5 1110 13.3

50 0.26 1.58 1.9 30.5 1374 13.3

52 0.26 1.58 1.9 31.5 1424 13.3

60 0.26 1.58 1.9 33.0 1617 13.3

61 0.26 1.58 1.9 33.0 1635 13.3

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

Conductor

0.7

0.7

0.7

0.7

Maximum Diameter

/km

0.26 0.7

0.7

0.7

0.7

mm mm mm mm mm kg/km

cable at 20°C

core (approx.) (approx.) (approx.) (approx.)

of of wire Conductor Insulation Sheath cable

Weight Conductor

No Diameter of of of of of Resistance

Thickness

450/750 V PVC INSULATED AND PVC SHEATHED CABLESPVC/PVC Flexible (IEC 60227, SPLN 42-6-3)

Nominal Nominal Overall Maximum

Thickness diameter

Page - 15

0.7

0.7

0.7

0.7

Page 18: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 5) Uo/U - 450/750 V Insulation : PVC Compound type D Operating Temperature Filler : Suitable material Maximum 70°C Sheath : PVC Compound type ST5 Colour Ident. : Insulation - Black with numbering code

Sheath - Black

CONTROL CABLE : 2.5 mm²

6 2.04 1.8 15.5 331 7.98

7 0.26 2.04 1.8 15.5 358 7.98

8 0.26 2.04 1.8 17.0 406 7.98

9 0.26 2.04 1.8 18.0 455 7.98

10 0.26 2.04 1.8 19.5 505 7.98

12 0.26 2.04 1.8 20.0 577 7.98

14 0.26 2.04 1.8 21.0 654 7.98

15 0.26 2.04 1.8 21.5 697 7.98

16 0.26 2.04 1.8 22.0 732 7.98

18 0.26 2.04 1.8 23.0 806 7.98

19 0.26 2.04 1.8 23.0 834 7.98

20 0.26 2.04 1.8 24.0 887 7.98

24 0.26 2.04 1.8 27.0 1049 7.98

30 0.26 2.04 1.8 28.5 1266 7.98

32 0.26 2.04 1.8 29.0 1342 7.98

37 0.26 2.04 1.9 31.0 1527 7.98

40 0.26 2.04 1.9 32.0 1644 7.98

50 0.26 2.04 2.0 35.5 2037 7.98

52 0.26 2.04 2.0 36.5 2115 7.98

60 0.26 2.04 2.1 39.0 2423 7.98

61 0.26 2.04 2.1 39.0 2450 7.98

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

/km

0.26 0.8

0.8

0.8

0.8

mm mm mm mm mm kg/km

cable at 20°C

core (approx.) (approx.) (approx.) (approx.)

of of wire Conductor Insulation Sheath cable

Conductor

No Diameter of of of of of Resistance

Maximum Diameter Thickness Thickness diameter Weight

450/750 V PVC INSULATED AND PVC SHEATHED CABLESPVC/PVC Flexible (IEC 60227, SPLN 42-6-3)

Conductor Nominal Nominal Overall Maximum

Page - 16

0.8

0.8

0.8

0.8

0.8

0.8

Page 19: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED AND PVC SHEATHED CABLES

Constructions :

Conductor (Annealed Copper)

Insulation (PVC Compound)

up to request)

Binding tape (Manufacturer's option)

Outer sheath (PVC Compound)

Page - 17

Unarmoured Cables

PVC/PVC (acc. to IEC 60502-1)

Filler (Polyprophylene yarn,or extruded filler

1 1

22

3

4

5 5

1

2

3

4

5

Note : Special application upon request* Available product in accordance to : SPLN, ICEA/NEMA,

AS standard or other requirement.* Flame retardant test acc to IEC 60332-3 Cat. A, B or C.* Anti termite performance.* Tin coated Copper conductor.* Polyethylene / Low smoke Halogen Free sheathed

Page 20: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED AND PVC SHEATHED CABLES

PVC/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2)

Insulation : PVC Compound type A Operating Temperature

Sheath : PVC Compound type ST1 Maximum 70°C

: Insulation - Black

Sheath - Black

SINGLE CORE

Conductor Nominal Nominal Overall Maximum

Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

Cross- Diameter of of of of of Resistance

section of wire Conductor Insulation Sheath cable cable at 20°C

area (approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

1.5 1 / 1.38 1.38 0.8 1.4 6.0 52 12.1

1.5 7 / 0.52 1.56 0.8 1.4 6.0 55 12.1

2.5 1 / 1.78 1.78 0.8 1.4 6.5 65 7.41

2.5 7 / 0.67 2.01 0.8 1.4 6.5 70 7.41

4 1 / 2.26 2.26 1.0 1.4 7.5 90 4.61

4 7 / 0.85 2.55 1.0 1.4 7.5 95 4.61

6 7 / 1.04 3.12 1.0 1.4 8.0 120 3.08

10 7 / 1.35 4.05 1.0 1.4 9.0 170 1.83

16 7 / 1.70 5.10 1.0 1.4 10.0 235 1.15

25 7 / 2.13 6.39 1.2 1.4 12.0 345 0.727

35 7 / 2.52 7.56 1.2 1.4 13.0 450 0.524

50 19 / 1.83 9.15 1.4 1.4 15.0 620 0.387

70 19 / 2.17 10.85 1.4 1.4 16.5 825 0.268

95 19 / 2.52 12.60 1.6 1.5 19.0 1105 0.193

120 37 / 2.03 14.21 1.6 1.5 21.0 1350 0.153

150 37 / 2.27 15.89 1.8 1.6 23.0 1680 0.124

185 37 / 2.52 17.64 2.0 1.7 25.5 2060 0.0991

240 61 / 2.26 20.34 2.2 1.8 28.5 2685 0.0754

300 61 / 2.52 22.68 2.4 1.9 31.5 3315 0.0601

400 61 / 2.86 25.74 2.6 2.0 35.5 4235 0.0470

500 61 / 3.20 28.80 2.8 2.1 39.0 5250 0.0366

630 91 / 2.96 32.56 2.8 2.2 43.0 6560 0.0283

800 127 / 2.85 37.05 2.8 2.3 48.0 8345 0.0221

1000 127 / 3.20 41.60 3.0 2.5 53.0 10455 0.0176

Page - 18

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 21: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED AND PVC SHEATHED CABLES

PVC/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2)

Insulation : PVC Compound type A Operating Temperature

Filler : Suitable material Maximum 70°C

Sheath : PVC Compound type ST1

: Insulation - Red,Black

Sheath - Black

TWO CORES

Conductor Nominal Nominal Overall Maximum

Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

Cross- Diameter of of of of of Resistance

section area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

1.5 1 / 1.38 1.38 0.8 1.8 10.5 125 12.1

1.5 7 / 0.52 1.56 0.8 1.8 10.5 130 12.1

2.5 1 / 1.78 1.78 0.8 1.8 11.0 155 7.41

2.5 7 / 0.67 2.01 0.8 1.8 11.5 165 7.41

4 1 / 2.26 2.26 1.0 1.8 13.0 215 4.61

4 7 / 0.85 2.55 1.0 1.8 13.5 225 4.61

6 7 / 1.04 3.12 1.0 1.8 14.5 280 3.08

10 7 / 1.35 4.05 1.0 1.8 16.5 390 1.83

16 7 / 1.70 5.10 1.0 1.8 18.5 535 1.15

25 7 / 2.13 6.39 1.2 1.8 22.0 785 0.727

35 7 / 2.52 7.56 1.2 1.8 24.5 1020 0.524

50 19 / 1.83 9.15 1.4 1.8 28.5 1395 0.387

70 19 / 2.17 10.85 1.4 1.9 32.0 1865 0.268

95 19 / 2.52 12.60 1.6 2.0 36.5 2490 0.193

120 37 / 2.03 14.21 1.6 2.1 40.0 3045 0.153

150 37 / 2.27 15.89 1.8 2.2 44.5 3775 0.124

185 37 / 2.52 17.64 2.0 2.4 49.0 4635 0.0991

240 61 / 2.26 20.34 2.2 2.6 55.5 6045 0.0754

300 61 / 2.52 22.68 2.4 2.7 61.5 7435 0.0601

Page - 19

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 22: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED AND PVC SHEATHED CABLES

PVC/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2)

Insulation : PVC Compound type A Operating Temperature

Filler : Suitable material Maximum 70°C

Sheath : PVC Compound type ST1

: Insulation - Red,Yellow , Blue

Sheath - Black

THREE CORES

Conductor Nominal Nominal Overall Maximum

Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

Cross- Diameter of of of of of Resistance

section area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

1.5 1 / 1.38 1.38 0.8 1.8 11.0 150 12.1

1.5 7 / 0.52 1.56 0.8 1.8 11.0 160 12.1

2.5 1 / 1.78 1.78 0.8 1.8 11.5 190 7.41

2.5 7 / 0.67 2.01 0.8 1.8 12.0 200 7.41

4 1 / 2.26 2.26 1.0 1.8 13.5 270 4.61

4 7 / 0.85 2.55 1.0 1.8 14.0 285 4.61

6 7 / 1.04 3.12 1.0 1.8 15.5 360 3.08

10 7 / 1.35 4.05 1.0 1.8 17.5 515 1.83

16 7 / 1.70 5.10 1.0 1.8 19.5 720 1.15

25 7 / 2.13 6.39 1.2 1.8 23.5 1065 0.727

35 7 / 2.52 7.56 1.2 1.8 26.0 1400 0.524

50 6.8 1.4 1.8 24.5 1730 0.387

70 8.2 1.4 2.0 28.0 2405 0.268

95 Three- 9.7 1.6 2.1 32.5 3305 0.193

120 Segmental 10.9 1.6 2.2 35.0 3950 0.153

150 Stranded 11.9 1.8 2.3 38.5 4835 0.124

185 13.6 2.0 2.5 43.0 6035 0.0991

240 15.8 2.2 2.7 49.0 8050 0.0754

300 17.5 2.4 2.9 53.5 10010 0.0601

Page - 20

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 23: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED AND PVC SHEATHED CABLES

PVC/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2)

Insulation : PVC Compound type A Operating Temperature

Filler : Suitable material Maximum 70°C

Sheath : PVC Compound type ST1

: Insulation - Red,Yellow , Blue , Black

Sheath - Black

FOUR CORES

Conductor Nominal Nominal Overall Maximum

Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

Cross- Diameter of of of of of Resistance

section area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

1.5 1 / 1.38 1.38 0.8 1.8 11.5 180 12.1

1.5 7 / 0.52 1.56 0.8 1.8 12.0 190 12.1

2.5 1 / 1.78 1.78 0.8 1.8 12.5 235 7.41

2.5 7 / 0.67 2.01 0.8 1.8 13.0 245 7.41

4 1 / 2.26 2.26 1.0 1.8 15.0 335 4.61

4 7 / 0.85 2.55 1.0 1.8 15.5 355 4.61

6 7 / 1.04 3.12 1.0 1.8 16.5 450 3.08

10 7 / 1.35 4.05 1.0 1.8 19.0 650 1.83

16 7 / 1.70 5.10 1.0 1.8 21.5 915 1.15

25 7 / 2.13 6.39 1.2 1.8 25.5 1370 0.727

35 7 / 2.52 7.56 1.2 1.8 28.5 1805 0.524

50 8.1 1.4 1.9 28.0 2245 0.387

70 9.7 1.4 2.1 32.0 3125 0.268

95 Four- 11.4 1.6 2.2 37.0 4295 0.193

120 Segmental 12.9 1.6 2.4 40.5 5165 0.153

150 Stranded 14.2 1.8 2.5 44.5 6335 0.124

185 16.0 2.0 2.7 49.5 7895 0.0991

240 18.2 2.2 2.9 55.5 10510 0.0754

300 20.6 2.4 3.1 62.0 13110 0.0601

Page - 21

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 24: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED AND PVC SHEATHED CABLES

PVC/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2)

Insulation : PVC Compound type A Operating Temperature

Filler : Suitable material Maximum 70°C

Sheath : PVC Compound type ST1

: Insulation - Black with numbering code

Sheath - Black

FIVE CORES

Conductor Nominal Nominal Overall Maximum

Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

Cross- Diameter of of of of of Resistance

section area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

1.5 1 / 1.38 1.38 0.8 1.8 12.5 215 12.1

1.5 7 / 0.52 1.56 0.8 1.8 13.0 225 12.1

2.5 1 / 1.78 1.78 0.8 1.8 13.5 275 7.41

2.5 7 / 0.67 2.01 0.8 1.8 14.0 290 7.41

4 1 / 2.26 2.26 1.0 1.8 16.0 400 4.61

4 7 / 0.85 2.55 1.0 1.8 17.0 425 4.61

6 7 / 1.04 3.12 1.0 1.8 18.0 545 3.08

10 7 / 1.35 4.05 1.0 1.8 21.0 790 1.83

16 7 / 1.70 5.10 1.0 1.8 23.5 1125 1.15

25 7 / 2.13 6.39 1.2 1.8 28.0 1680 0.727

35 7 / 2.52 7.56 1.2 1.9 31.5 2245 0.524

50 19 / 1.83 9.15 1.4 2.1 37.5 3130 0.387

Page - 22

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 25: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED AND PVC SHEATHED CABLES

PVC/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1)

Insulation : PVC Compound type A Operating Temperature

Filler (if necessary): Suitable material Maximum 70°C

Sheath : PVC Compound type ST1

: Insulation - Black with numbering code

Sheath - Black

CONTROL CABLE : 1.5 mm² (Solid conductor)

Conductor Nominal Nominal Overall Maximum

No Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

of Cross-section Diameter of of of of of Resistance

core area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

6 1.5 1 / 1.38 1.38 0.8 1.8 13.5 240 12.1

7 1.5 1 / 1.38 1.38 0.8 1.8 13.5 260 12.1

8 1.5 1 / 1.38 1.38 0.8 1.8 14.5 290 12.1

9 1.5 1 / 1.38 1.38 0.8 1.8 15.5 325 12.1

10 1.5 1 / 1.38 1.38 0.8 1.8 16.5 360 12.1

12 1.5 1 / 1.38 1.38 0.8 1.8 17.0 410 12.1

14 1.5 1 / 1.38 1.38 0.8 1.8 18.0 460 12.1

15 1.5 1 / 1.38 1.38 0.8 1.8 18.5 490 12.1

16 1.5 1 / 1.38 1.38 0.8 1.8 19.0 515 12.1

18 1.5 1 / 1.38 1.38 0.8 1.8 20.0 565 12.1

19 1.5 1 / 1.38 1.38 0.8 1.8 20.0 585 12.1

20 1.5 1 / 1.38 1.38 0.8 1.8 20.5 615 12.1

21 1.5 1 / 1.38 1.38 0.8 1.8 21.5 650 12.1

24 1.5 1 / 1.38 1.38 0.8 1.8 23.0 735 12.1

30 1.5 1 / 1.38 1.38 0.8 1.8 24.5 880 12.1

32 1.5 1 / 1.38 1.38 0.8 1.8 25.0 930 12.1

37 1.5 1 / 1.38 1.38 0.8 1.8 26.5 1050 12.1

40 1.5 1 / 1.38 1.38 0.8 1.8 27.5 1130 12.1

50 1.5 1 / 1.38 1.38 0.8 1.9 30.0 1395 12.1

52 1.5 1 / 1.38 1.38 0.8 1.9 31.0 1450 12.1

60 1.5 1 / 1.38 1.38 0.8 2.0 33.0 1665 12.1

61 1.5 1 / 1.38 1.38 0.8 2.0 33.0 1685 12.1

Page - 23

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 26: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED AND PVC SHEATHED CABLES

PVC/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2)

Insulation : PVC Compound type A Operating Temperature

Filler (if necessary): Suitable material Maximum 70°C

Sheath : PVC Compound type ST1

: Insulation - Black with numbering code

Sheath - Black

CONTROL CABLE : 1.5 mm² (Stranded conductor)

Conductor Nominal Nominal Overall Maximum

No Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

of Cross-section Diameter of of of of of Resistance

core area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

6 1.5 7 / 0.52 1.56 0.8 1.8 14.0 255 12.1

7 1.5 7 / 0.52 1.56 0.8 1.8 14.0 275 12.1

8 1.5 7 / 0.52 1.56 0.8 1.8 15.0 310 12.1

9 1.5 7 / 0.52 1.56 0.8 1.8 16.0 345 12.1

10 1.5 7 / 0.52 1.56 0.8 1.8 17.5 380 12.1

12 1.5 7 / 0.52 1.56 0.8 1.8 18.0 430 12.1

14 1.5 7 / 0.52 1.56 0.8 1.8 19.0 490 12.1

15 1.5 7 / 0.52 1.56 0.8 1.8 19.5 515 12.1

16 1.5 7 / 0.52 1.56 0.8 1.8 20.0 545 12.1

18 1.5 7 / 0.52 1.56 0.8 1.8 21.0 600 12.1

19 1.5 7 / 0.52 1.56 0.8 1.8 21.0 620 12.1

20 1.5 7 / 0.52 1.56 0.8 1.8 21.5 650 12.1

21 1.5 7 / 0.52 1.56 0.8 1.8 22.5 685 12.1

24 1.5 7 / 0.52 1.56 0.8 1.8 24.5 775 12.1

30 1.5 7 / 0.52 1.56 0.8 1.8 25.5 930 12.1

32 1.5 7 / 0.52 1.56 0.8 1.8 26.0 980 12.1

37 1.5 7 / 0.52 1.56 0.8 1.8 27.5 1110 12.1

40 1.5 7 / 0.52 1.56 0.8 1.8 28.5 1195 12.1

50 1.5 7 / 0.52 1.56 0.8 1.9 32.0 1475 12.1

52 1.5 7 / 0.52 1.56 0.8 1.9 32.5 1530 12.1

60 1.5 7 / 0.52 1.56 0.8 2.0 35.0 1760 12.1

61 1.5 7 / 0.52 1.56 0.8 2.0 35.0 1780 12.1

Page - 24

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 27: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED AND PVC SHEATHED CABLES

PVC/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1)

Insulation : PVC Compound type A Operating Temperature

Filler (if necessary): Suitable material Maximum 70°C

Sheath : PVC Compound type ST1

: Insulation - Black with numbering code

Sheath - Black

CONTROL CABLE : 2.5 mm² (Solid conductor)

Conductor Nominal Nominal Overall Maximum

No Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

of Cross-section Diameter of of of of of Resistance

core area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

6 2.5 1 / 1.78 1.78 0.8 1.8 14.5 315 7.41

7 2.5 1 / 1.78 1.78 0.8 1.8 14.5 340 7.41

8 2.5 1 / 1.78 1.78 0.8 1.8 16.0 390 7.41

9 2.5 1 / 1.78 1.78 0.8 1.8 17.0 435 7.41

10 2.5 1 / 1.78 1.78 0.8 1.8 18.5 480 7.41

12 2.5 1 / 1.78 1.78 0.8 1.8 19.0 550 7.41

14 2.5 1 / 1.78 1.78 0.8 1.8 20.0 625 7.41

15 2.5 1 / 1.78 1.78 0.8 1.8 20.5 665 7.41

16 2.5 1 / 1.78 1.78 0.8 1.8 21.0 705 7.41

18 2.5 1 / 1.78 1.78 0.8 1.8 22.0 775 7.41

19 2.5 1 / 1.78 1.78 0.8 1.8 22.0 800 7.41

20 2.5 1 / 1.78 1.78 0.8 1.8 22.5 845 7.41

21 2.5 1 / 1.78 1.78 0.8 1.8 23.5 890 7.41

24 2.5 1 / 1.78 1.78 0.8 1.8 25.5 1010 7.41

30 2.5 1 / 1.78 1.78 0.8 1.8 27.0 1220 7.41

32 2.5 1 / 1.78 1.78 0.8 1.8 27.5 1290 7.41

37 2.5 1 / 1.78 1.78 0.8 1.9 29.5 1475 7.41

40 2.5 1 / 1.78 1.78 0.8 1.9 30.5 1590 7.41

50 2.5 1 / 1.78 1.78 0.8 2.0 33.5 1970 7.41

52 2.5 1 / 1.78 1.78 0.8 2.0 34.5 2045 7.41

60 2.5 1 / 1.78 1.78 0.8 2.1 37.0 2345 7.41

61 2.5 1 / 1.78 1.78 0.8 2.1 37.0 2380 7.41

Page - 25

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 28: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED AND PVC SHEATHED CABLES

PVC/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2)

Insulation : PVC Compound type A Operating Temperature

Filler (if necessary): Suitable material Maximum 70°C

Sheath : PVC Compound type ST1

: Insulation - Black with numbering code

Sheath - Black

CONTROL CABLE : 2.5 mm² (Stranded conductor)

Conductor Nominal Nominal Overall Maximum

No Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

of Cross-section Diameter of of of of of Resistance

core area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

6 2.5 7 / 0.67 2.01 0.8 1.8 15.5 330 7.41

7 2.5 7 / 0.67 2.01 0.8 1.8 15.5 360 7.41

8 2.5 7 / 0.67 2.01 0.8 1.8 16.5 410 7.41

9 2.5 7 / 0.67 2.01 0.8 1.8 17.5 460 7.41

10 2.5 7 / 0.67 2.01 0.8 1.8 19.0 505 7.41

12 2.5 7 / 0.67 2.01 0.8 1.8 19.5 580 7.41

14 2.5 7 / 0.67 2.01 0.8 1.8 20.5 660 7.41

15 2.5 7 / 0.67 2.01 0.8 1.8 21.0 700 7.41

16 2.5 7 / 0.67 2.01 0.8 1.8 22.0 740 7.41

18 2.5 7 / 0.67 2.01 0.8 1.8 23.0 815 7.41

19 2.5 7 / 0.67 2.01 0.8 1.8 23.0 845 7.41

20 2.5 7 / 0.67 2.01 0.8 1.8 23.5 890 7.41

21 2.5 7 / 0.67 2.01 0.8 1.8 25.0 930 7.41

24 2.5 7 / 0.67 2.01 0.8 1.8 26.5 1065 7.41

30 2.5 7 / 0.67 2.01 0.8 1.8 28.5 1285 7.41

32 2.5 7 / 0.67 2.01 0.8 1.8 29.0 1360 7.41

37 2.5 7 / 0.67 2.01 0.8 1.9 30.5 1555 7.41

40 2.5 7 / 0.67 2.01 0.8 1.9 32.0 1675 7.41

50 2.5 7 / 0.67 2.01 0.8 2.0 35.5 2075 7.41

52 2.5 7 / 0.67 2.01 0.8 2.0 36.5 2155 7.41

60 2.5 7 / 0.67 2.01 0.8 2.1 38.5 2475 7.41

61 2.5 7 / 0.67 2.01 0.8 2.1 38.5 2510 7.41

Page - 26

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 29: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED AND PVC SHEATHED CABLES

PVC/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

Insulation : PVC Compound type A Operating Temperature

Filler (if necessary): Suitable material Maximum 70°C

Sheath : PVC Compound type ST1

: Insulation - Black with numbering code

Sheath - Black

CONTROL CABLE : 4 mm² (Solid conductor)

Conductor Nominal Nominal Overall Maximum

No Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

of Cross-section Diameter of of of of of Resistance

core area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

6 4 1 / 2.26 2.26 1.0 1.8 17.5 460 4.61

7 4 1 / 2.26 2.26 1.0 1.8 17.5 500 4.61

8 4 1 / 2.26 2.26 1.0 1.8 19.0 570 4.61

9 4 1 / 2.26 2.26 1.0 1.8 20.0 640 4.61

10 4 1 / 2.26 2.26 1.0 1.8 22.0 710 4.61

12 4 1 / 2.26 2.26 1.0 1.8 22.5 820 4.61

14 4 1 / 2.26 2.26 1.0 1.8 24.0 940 4.61

15 4 1 / 2.26 2.26 1.0 1.8 24.5 995 4.61

16 4 1 / 2.26 2.26 1.0 1.8 25.0 1060 4.61

18 4 1 / 2.26 2.26 1.0 1.8 26.5 1165 4.61

19 4 1 / 2.26 2.26 1.0 1.8 26.5 1210 4.61

20 4 1 / 2.26 2.26 1.0 1.8 27.0 1280 4.61

21 4 1 / 2.26 2.26 1.0 1.8 28.5 1340 4.61

24 4 1 / 2.26 2.26 1.0 1.9 31.0 1540 4.61

30 4 1 / 2.26 2.26 1.0 2.0 33.0 1890 4.61

32 4 1 / 2.26 2.26 1.0 2.0 34.0 2000 4.61

37 4 1 / 2.26 2.26 1.0 2.1 36.0 2285 4.61

40 4 1 / 2.26 2.26 1.0 2.1 37.5 2465 4.61

50 4 1 / 2.26 2.26 1.0 2.3 41.5 3070 4.61

52 4 1 / 2.26 2.26 1.0 2.3 43.0 3190 4.61

60 4 1 / 2.26 2.26 1.0 2.4 45.5 3660 4.61

61 4 1 / 2.26 2.26 1.0 2.4 45.5 3715 4.61

Page - 27

Unarmoured Cables

(to IEC 60228 clas 1) Uo/U - 600/1000 V

Colour Ident.

W/km

Page 30: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED AND PVC SHEATHED CABLES

PVC/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

Insulation : PVC Compound type A Operating Temperature

Filler (if necessary): Suitable material Maximum 70°C

Sheath : PVC Compound type ST1

: Insulation - Black with numbering code

Sheath - Black

CONTROL CABLE : 4 mm² (Stranded conductor)

Conductor Nominal Nominal Overall Maximum

No Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

of Cross-section Diameter of of of of of Resistance

core area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

6 4 7 / 0.85 2.55 1.0 1.8 18.5 485 4.61

7 4 7 / 0.85 2.55 1.0 1.8 18.5 535 4.61

8 4 7 / 0.85 2.55 1.0 1.8 20.0 605 4.61

9 4 7 / 0.85 2.55 1.0 1.8 21.0 675 4.61

10 4 7 / 0.85 2.55 1.0 1.8 23.0 750 4.61

12 4 7 / 0.85 2.55 1.0 1.8 24.0 865 4.61

14 4 7 / 0.85 2.55 1.0 1.8 25.0 990 4.61

15 4 7 / 0.85 2.55 1.0 1.8 25.5 1050 4.61

16 4 7 / 0.85 2.55 1.0 1.8 26.5 1115 4.61

18 4 7 / 0.85 2.55 1.0 1.8 28.0 1230 4.61

19 4 7 / 0.85 2.55 1.0 1.8 28.0 1280 4.61

20 4 7 / 0.85 2.55 1.0 1.8 29.0 1350 4.61

21 4 7 / 0.85 2.55 1.0 1.8 30.5 1420 4.61

24 4 7 / 0.85 2.55 1.0 1.9 33.0 1625 4.61

30 4 7 / 0.85 2.55 1.0 2.0 35.0 1990 4.61

32 4 7 / 0.85 2.55 1.0 2.0 35.5 2110 4.61

37 4 7 / 0.85 2.55 1.0 2.1 38.0 2410 4.61

40 4 7 / 0.85 2.55 1.0 2.1 39.5 2600 4.61

50 4 7 / 0.85 2.55 1.0 2.3 44.0 3240 4.61

52 4 7 / 0.85 2.55 1.0 2.3 45.5 3365 4.61

60 4 7 / 0.85 2.55 1.0 2.4 48.5 3860 4.61

61 4 7 / 0.85 2.55 1.0 2.4 48.5 3915 4.61

Page - 28

Unarmoured Cables

(to IEC 60228 clas 2) Uo/U - 600/1000 V

Colour Ident.

W/km

Page 31: LV2009

Section 2 - PVC Insulated CablesUnarmoured Cables

Constructions : Conductor (Annealed Copper) Insulation (PVC Compound) Filler (Polyprophylene yarn,or extruded filler up to request) Binding tape (Manufacturer's option) Copper Tape screen Binding tape (Manufacturer's option) Outer sheath (PVC Compound)

600/1000 V PVC INSULATED, METALLIC SCREENED AND PVC SHEATHED CABLESPVC/PVC-S (IEC 60502-1)

Page - 29

123

4567

1

2

3

4

5

7

6

Note : Special application upon request* Available product in accordance to : SPLN, ICEA/NEMA,

AS standard or other requirement.* Flame retardant test acc to IEC 60332-3 Cat. A, B or C.* Anti termite performance.* Tin coated Copper conductor.* Copper wire screen.* Polyethylene / Low smoke Halogen Free sheathed

Page 32: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Metallic screen : Annealed Copper tape Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Red,Black

Sheath - Black

TWO CORES

1.5 1 / 1.38 1.38 0.8 0.1 1.8 10.5 145 12.1

1.5 7 / 0.52 1.56 0.8 0.1 1.8 11.0 147 12.1

2.5 1 / 1.78 1.78 0.8 0.1 1.8 11.5 176 7.41

2.5 7 / 0.67 2.01 0.8 0.1 1.8 11.5 179 7.41

4 1 / 2.26 2.26 1.0 0.1 1.8 13.0 240 4.61

4 7 / 0.85 2.55 1.0 0.1 1.8 13.5 246 4.61

6 7 / 1.04 3.12 1.0 0.1 1.8 14.5 304 3.08

10 7 / 1.35 4.05 1.0 0.1 1.8 16.5 418 1.83

16 7 / 1.70 5.10 1.0 0.1 1.8 18.5 568 1.15

25 7 / 2.13 6.39 1.2 0.1 1.8 22.0 822 0.727

35 7 / 2.52 7.56 1.2 0.1 1.8 24.5 1064 0.524

50 19 / 1.83 9.15 1.4 0.1 1.8 28.5 1450 0.387

70 19 / 2.17 10.85 1.4 0.1 1.9 32.0 1910 0.268

95 19 / 2.52 12.60 1.6 0.1 2.0 36.5 2542 0.193

120 37 / 2.03 14.21 1.6 0.1 2.1 40.0 3103 0.153

150 37 / 2.27 15.89 1.8 0.1 2.2 44.5 3840 0.124

185 37 / 2.52 17.64 2.0 0.1 2.4 49.0 4679 0.0991

240 61 / 2.26 20.34 2.2 0.1 2.6 55.5 6096 0.0754

300 61 / 2.52 22.68 2.4 0.1 2.7 61.5 7523 0.0601

Thickness

PVC/PVC-S (IEC 60502-1)

Nominal

Cross- of

Thickness

Overall

diameter

of

Nominal

(approx.)

600/1000 V PVC INSULATED, METALLIC SCREENED AND PVC SHEATHED CABLES

Diameter

of

Nominal

Thickness

of

Nominal

No./

Diameter

at 20°Ccable

mm

Conductor

mm² No./mm

Conductorsection area of wire

(approx.)

Weight

of

Maximum

Conductor

Resistance

cable

mm mm

Sheath

mm

Insulation

(approx.)

/kmkg/km

(approx.) (approx.)

of

Copper tape

mm

Page - 30

Page 33: LV2009

Section 2 - PVC Insulated CablesUnarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Metallic screen : Annealed Copper tape Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Red,Yellow , Blue

Sheath - Black

THREE CORES

1.5 1 / 1.38 1.38 0.8 0.1 1.8 11.0 173 12.1

1.5 7 / 0.52 1.56 0.8 0.1 1.8 11.5 174 12.1

2.5 1 / 1.78 1.78 0.8 0.1 1.8 12.0 214 7.41

2.5 7 / 0.67 2.01 0.8 0.1 1.8 12.5 220 7.41

4 1 / 2.26 2.26 1.0 0.1 1.8 14.0 298 4.61

4 7 / 0.85 2.55 1.0 0.1 1.8 14.5 306 4.61

6 7 / 1.04 3.12 1.0 0.1 1.8 15.0 385 3.08

10 7 / 1.35 4.05 1.0 0.1 1.8 17.5 542 1.83

16 7 / 1.70 5.10 1.0 0.1 1.8 20.0 753 1.15

25 7 / 2.13 6.39 1.2 0.1 1.8 23.5 1108 0.727

35 7 / 2.52 7.56 1.2 0.1 1.8 26.0 1445 0.524

50 6.8 1.4 0.1 1.9 25.0 1774 0.387

70 8.2 1.4 0.1 2.0 28.0 2439 0.268

95 9.7 1.6 0.1 2.1 32.5 3348 0.193

120 10.9 1.6 0.1 2.2 35.0 3994 0.153

150 11.9 1.8 0.1 2.4 38.5 4885 0.124

185 13.6 2.0 0.1 2.5 43.0 6076 0.0991

240 15.8 2.2 0.1 2.7 48.5 8095 0.0754

300 17.5 2.4 0.1 2.9 53.5 10060 0.0601

Maximum

Nominal No./ Diameter Thickness

Conductor Nominal Nominal Overall

of of

Thickness diameter Weight Conductor

at 20°Csection area of wire Conductor Insulation

of of ResistanceCross- Diameter

Segmental

Stranded

kg/kmmm mmmm² No./mm mm mm

600/1000 V PVC INSULATED, METALLIC SCREENED AND PVC SHEATHED CABLESPVC/PVC-S (IEC 60502-1)

/km

Three-

(approx.) (approx.) (approx.)(approx.)

Sheath cable cable

of

Thickness

of

Copper tape

mm

(approx.)

Nominal

Page - 31

Page 34: LV2009

Section 2 - PVC Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Metallic screen : Annealed Copper tape Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Red,Yellow , Blue , Black

Sheath - Black

FOUR CORES

1.5 1 / 1.38 1.38 0.8 0.1 1.8 12.0 202 12.1

1.5 7 / 0.52 1.56 0.8 0.1 1.8 12.5 206 12.1

2.5 1 / 1.78 1.78 0.8 0.1 1.8 13.0 260 7.41

2.5 7 / 0.67 2.01 0.8 0.1 1.8 13.5 265 7.41

4 1 / 2.26 2.26 1.0 0.1 1.8 15.0 366 4.61

4 7 / 0.85 2.55 1.0 0.1 1.8 15.5 378 4.61

6 7 / 1.04 3.12 1.0 0.1 1.8 17.0 482 3.08

10 7 / 1.35 4.05 1.0 0.1 1.8 19.5 682 1.83

16 7 / 1.70 5.10 1.0 0.1 1.8 21.5 957 1.15

25 7 / 2.13 6.39 1.2 0.1 1.8 26.0 1412 0.727

35 7 / 2.52 7.56 1.2 0.1 1.8 28.5 1856 0.524

50 8.1 1.4 0.1 2.0 28.5 2302 0.387

70 9.7 1.4 0.1 2.1 32.0 3177 0.268

95 11.4 1.6 0.1 2.2 37.0 4360 0.193

120 12.9 1.6 0.1 2.4 40.5 5217 0.153

150 14.2 1.8 0.1 2.5 44.5 6394 0.124

185 16.0 2.0 0.1 2.7 49.5 7962 0.0991

240 18.2 2.2 0.1 2.9 55.5 10591 0.0754

300 20.6 2.4 0.1 3.1 61.5 13179 0.0601

Nominal

Stranded

Segmental

Four-

600/1000 V PVC INSULATED, METALLIC SCREENED AND PVC SHEATHED CABLESPVC/PVC-S (IEC 60502-1)

No./ Diameter Thickness

Conductor Nominal Nominal Overall Maximum

ResistanceCross- Diameter of of

Thickness diameter Weight ConductorNominal

of wire Conductor Insulation

of of of

/kmmm² No./mm mm mm

Sheath cable cable at 20°Csection area

mm mm

(approx.) (approx.) (approx.) (approx.)

kg/km

Thickness

of

Copper tape

mm

(approx.)

Page - 32

Page 35: LV2009

Section 2 - PVC Insulated CablesUnarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Metallic screen : Annealed Copper tape Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Black with numbering code

Sheath - Black

FIVE CORES

1.5 1 / 1.38 1.38 0.8 0.1 1.8 12.5 238 12.1

1.5 7 / 0.52 1.56 0.8 0.1 1.8 13.5 244 12.1

2.5 1 / 1.78 1.78 0.8 0.1 1.8 14.0 302 7.41

2.5 7 / 0.67 2.01 0.8 0.1 1.8 14.5 312 7.41

4 1 / 2.26 2.26 1.0 0.1 1.8 16.5 434 4.61

4 7 / 0.85 2.55 1.0 0.1 1.8 17.0 450 4.61

6 7 / 1.04 3.12 1.0 0.1 1.8 18.5 578 3.08

10 7 / 1.35 4.05 1.0 0.1 1.8 21.0 827 1.83

16 7 / 1.70 5.10 1.0 0.1 1.8 24.0 1166 1.15

25 7 / 2.13 6.39 1.2 0.1 1.8 28.5 1730 0.727

35 7 / 2.52 7.56 1.2 0.1 1.9 31.5 2286 0.524

50 19 / 1.83 9.15 1.4 0.1 2.1 37.5 3057 0.387

Conductor Nominal Nominal OverallNominal

Thickness diameter Weight ConductorNominal No./ Diameter Thickness

section area of wire Conductor Insulation

of ofCross- Diameter of of

mm mm kg/km /kmmm² No./mm mm mm

(approx.) (approx.)

600/1000 V PVC INSULATED, METALLIC SCREENED AND PVC SHEATHED CABLESPVC/PVC-S (IEC 60502-1)

Sheath cable cable at 20°C

(approx.) (approx.)

Maximum

of Resistance

mm

(approx.)

Page - 33

Thickness

of

Copper tape

Page 36: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED, ALUMINIUM WIRE ARMOURED AND PVC SHEATHED CABLES

Constructions :

Conductor (Annealed Copper)

Insulation (PVC Compound)

Inner Covering (PVC Compound)

Binding tape (Manufacturer's option)

Outer sheath (PVC Compound)

600/1000 V PVC INSULATED, STEEL WIRE ARMOURED AND PVC SHEATHED CABLES

Constructions :

Conductor (Annealed Copper)

Insulation (PVC Compound)

up to request)

Binding tape (Manufacturer's option)

Inner Covering (PVC Compound)

Binding tape (Manufacturer's option)

Outer sheath (PVC Compound)

Page - 34

Armoured Cables

PVC/AWA/PVC (acc. to IEC 60502-1)

Round Aluminium Wire armour

PVC/SWA/PVC (acc. to IEC 60502-1)

Filler (Polyprophylene yarn,or extruded filler

Galvanized Round Steel Wire armour

11

2

3

5

4

6

7

8

2

3

4

5

6

7

8

1

2

3

4

5

6

1

2

3

4

5

6

Note : Special application upon request* Available product in accordance to : SPLN, ICEA/NEMA,

AS standard or other requirement.* Flame retardant test acc to IEC 60332-3 Cat. A, B or C.* Anti termite performance.* Tin coated Copper conductor.* Polyethylene / Low smoke Halogen Free sheathed

Page 37: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED,ALUMINIUM WIRE ARMOURED AND PVC SHEATHED CABLES

PVC/AWA/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2)

Insulation : PVC Compound type A Operating Temperature

Inner covering : PVC Compound ST1 Maximum 70°C

Armour

Sheath : PVC Compound type ST1

: Insulation - Black

Sheath - Black

SINGLE CORE

Conductor Nominal Nominal Nominal Nominal Overall Maximum

Nominal No./ Diameter Thickness Thickness diameter of Thickness diameter Weight Conductor

Cross- Diameter of of of inner of of of Resistance

section of wire Conductor Insulation covering wire Sheath cable cable at 20°C

area (approx.) (approx.) (approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm mm mm kg/km

16 7 / 1.70 5.10 1.0 1.0 0.8 1.8 14.5 370 1.15

25 7 / 2.13 6.39 1.2 1.0 0.8 1.8 16.5 495 0.727

35 7 / 2.52 7.56 1.2 1.0 0.8 1.8 17.5 620 0.524

50 19 / 1.83 9.15 1.4 1.0 1.25 1.8 20.5 845 0.387

70 19 / 2.17 10.85 1.4 1.0 1.25 1.8 22.0 1075 0.268

95 19 / 2.52 12.60 1.6 1.0 1.25 1.8 24.5 1380 0.193

120 37 / 2.03 14.21 1.6 1.0 1.6 1.8 27.0 1705 0.153

150 37 / 2.27 15.89 1.8 1.0 1.6 1.8 29.0 2054 0.124

185 37 / 2.52 17.64 2.0 1.0 1.6 1.8 31.0 2450 0.0991

240 61 / 2.26 20.34 2.2 1.0 1.6 1.9 34.0 3110 0.0754

300 61 / 2.52 22.68 2.4 1.0 2.0 2.0 38.0 3865 0.0601

400 61 / 2.86 25.74 2.6 1.2 2.0 2.1 42.0 4885 0.0470

500 61 / 3.20 28.80 2.8 1.2 2.0 2.2 46.0 5965 0.0366

630 91 / 2.96 32.56 2.8 1.2 2.0 2.4 50.0 7335 0.0283

800 127 / 2.85 37.05 2.8 1.4 2.5 2.5 56.0 9410 0.0221

1000 127 / 3.20 41.60 3.0 1.4 2.5 2.7 61.0 11635 0.0176

Page - 35

Armoured Cables

Uo/U - 600/1000 V

: Aluminium Wire

Colour Ident.

Aluminium

W/km

Page 38: LV2009

Section 2 - PVC Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Inner covering : PVC Compound Armour : Galvanized Steel Wire Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Red,Black

Sheath - Black

TWO CORES

1.5 1 / 1.38 1.38 0.8 1.0 0.8 1.8 14.0 332 12.1

1.5 7 / 0.52 1.56 0.8 1.0 0.8 1.8 14.5 347 12.1

2.5 1 / 1.78 1.78 0.8 1.0 0.8 1.8 15.0 380 7.41

2.5 7 / 0.67 2.01 0.8 1.0 0.8 1.8 15.5 395 7.41

4 1 / 2.26 2.26 1.0 1.0 0.8 1.8 16.5 473 4.61

4 7 / 0.85 2.55 1.0 1.0 0.8 1.8 17.5 494 4.61

6 7 / 1.04 3.12 1.0 1.0 1.25 1.8 19.0 667 3.08

10 7 / 1.35 4.05 1.0 1.0 1.25 1.8 21.0 837 1.83

16 7 / 1.70 5.10 1.0 1.0 1.25 1.8 23.0 1019 1.15

25 7 / 2.13 6.39 1.2 1.0 1.6 1.8 27.5 1507 0.727

35 7 / 2.52 7.56 1.2 1.0 1.6 1.8 30.0 1810 0.524

50 19 / 1.83 9.15 1.4 1.0 1.6 1.9 34.0 2318 0.387

70 19 / 2.17 10.85 1.4 1.0 2.0 2.0 38.0 3122 0.268

95 19 / 2.52 12.60 1.6 1.2 2.0 2.2 43.5 3987 0.193

120 37 / 2.03 14.21 1.6 1.2 2.0 2.3 47.0 4695 0.153

150 37 / 2.27 15.89 1.8 1.2 2.5 2.4 52.0 5994 0.124

185 37 / 2.52 17.64 2.0 1.4 2.5 2.6 57.0 7109 0.0991

240 61 / 2.26 20.34 2.2 1.4 2.5 2.8 63.5 8827 0.0754

300 61 / 2.52 22.68 2.4 1.6 2.5 2.9 70.0 10574 0.0601

(approx.)

mm mm mm kg/kmmmmmmm² No./mm mm

area (approx.) (approx.)

Cross- Diameter of of

section of wire Conductor

Maximum

(approx.)

Insulation

Conductor

of of of

Thickness

of Inner

covering

Diameter Thickness

OverallNominal Nominal

Diameter Weightdiameter

Nominal

cable cable at 20°C

(approx.)

600/1000 V PVC INSULATED, STEEL WIRE ARMOURED AND PVC SHEATHED CABLESPVC/SWA/PVC (IEC 60502-1)

Thickness

Sheath

Conductor

/km

Resistance

Nominal No./

of Galv.

Steel wire

Page - 36

Page 39: LV2009

Section 2 - PVC Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Inner covering : PVC Compound Armour : Galvanized Steel Wire Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Red,Yellow, Blue

Sheath - Black

THREE CORES

1.5 1 / 1.38 1.38 0.8 1.0 0.8 1.8 14.5 371 12.1

1.5 7 / 0.52 1.56 0.8 1.0 0.8 1.8 15.0 385 12.1

2.5 1 / 1.78 1.78 0.8 1.0 0.8 1.8 15.5 429 7.41

2.5 7 / 0.67 2.01 0.8 1.0 0.8 1.8 16.0 446 7.41

4 1 / 2.26 2.26 1.0 1.0 0.8 1.8 18.0 637 4.61

4 7 / 0.85 2.55 1.0 1.0 1.25 1.8 18.5 660 4.61

6 7 / 1.04 3.12 1.0 1.0 1.25 1.8 20.0 768 3.08

10 7 / 1.35 4.05 1.0 1.0 1.25 1.8 22.0 973 1.83

16 7 / 1.70 5.10 1.0 1.0 1.25 1.8 24.0 1229 1.15

25 7 / 2.13 6.39 1.2 1.0 1.6 1.8 29.0 1819 0.727

35 7 / 2.52 7.56 1.2 1.0 1.6 1.8 31.5 2230 0.524

50 6.8 1.4 1.0 1.6 2.0 30.5 2558 0.387

70 8.2 1.4 1.2 2.0 2.1 34.5 3577 0.268

95 9.7 1.6 1.2 2.0 2.2 39.0 4653 0.193

120 10.9 1.6 1.2 2.0 2.3 42.0 5410 0.153

150 11.9 1.8 1.4 2.5 2.5 46.0 6830 0.124

185 13.6 2.0 1.4 2.5 2.7 51.0 8260 0.0991

240 15.8 2.2 1.6 2.5 2.9 57.0 10632 0.0754

300 17.5 2.4 1.6 2.5 3.1 62.0 12795 0.0601

Sector Shape

mm mm

(approx.)

mm² No./mm /km

(approx.) (approx.)

mm mm kg/km

(approx.)

Maximum

Sheath cable

Thickness

Resistance

cable at 20°C

Conductor Nominal Nominal OverallNominal

mm mm

area (approx.)

Nominal No./ Diameter Thickness ConductorThickness Diameter

of of of Galv. ofof Inner

diameter Weight

Conductor Insulation

Cross- Diameter of of

600/1000 V PVC INSULATED, STEEL WIRE ARMOURED AND PVC SHEATHED CABLESPVC/SWA/PVC (IEC 60502-1)

Page - 37

covering Steel wiresection of wire

stranded

Page 40: LV2009

Section 2 - PVC Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Inner covering : PVC Compound Armour : Galvanized Steel Wire Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Red,Yellow, Blue, Black

Sheath - Black

FOUR CORES

1.5 1 / 1.38 1.38 0.8 1.0 0.8 1.8 15.5 412 12.1

1.5 7 / 0.52 1.56 0.8 1.0 0.8 1.8 16.0 434 12.1

2.5 1 / 1.78 1.78 0.8 1.0 0.8 1.8 16.5 486 7.41

2.5 7 / 0.67 2.01 0.8 1.0 0.8 1.8 17.0 508 7.41

4 1 / 2.26 2.26 1.0 1.0 0.8 1.8 19.5 736 4.61

4 7 / 0.85 2.55 1.0 1.0 1.25 1.8 20.0 762 4.61

6 7 / 1.04 3.12 1.0 1.0 1.25 1.8 21.0 894 3.08

10 7 / 1.35 4.05 1.0 1.0 1.25 1.8 23.5 1142 1.83

16 7 / 1.70 5.10 1.0 1.0 1.6 1.8 27.0 1621 1.15

25 7 / 2.13 6.39 1.2 1.0 1.6 1.8 31.0 2183 0.727

35 7 / 2.52 7.56 1.2 1.0 1.6 1.9 34.0 2698 0.524

50 8.1 1.4 1.2 2.0 2.1 35.0 3467 0.387

70 9.7 1.4 1.2 2.0 2.2 38.5 4455 0.268

95 11.4 1.6 1.2 2.5 2.4 44.5 6222 0.193

120 12.9 1.6 1.4 2.5 2.5 48.5 7248 0.153

150 14.2 1.8 1.4 2.5 2.7 52.5 8663 0.124

185 16.0 2.0 1.6 2.5 2.9 58.0 10503 0.0991

240 18.2 2.2 1.6 2.5 3.1 63.5 13414 0.0754

300 20.6 2.4 1.6 2.5 3.3 70.0 16298 0.0601

Conductor Nominal MaximumNominal

PVC/SWA/PVC (IEC 60502-1)

Weight ConductorNominal No./ Diameter Thickness Thickness Diameter

of ResistanceCross- Diameter of of of Inner of Galv. of

at 20°Csection of wire Conductor Insulation covering Steel wire Sheath cable

stranded

mm² No./mm mm

cable

area (approx.) (approx.) (approx.) (approx.)

/km

Sector Shape

mm mm

(approx.)

kg/kmmm

600/1000 V PVC INSULATED, STEEL WIRE ARMOURED AND PVC SHEATHED CABLES

Page - 38

mm

of

mm

Thickness

Nominal

diameter

Overall

Page 41: LV2009

Section 2 - PVC Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Inner covering : PVC Compound Armour : Galvanized Steel Wire Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Black with numbering code

Sheath - Black

FIVE CORES

1.5 1 / 1.38 1.38 0.8 1.0 0.8 1.8 16.5 465 12.1

1.5 7 / 0.52 1.56 0.8 1.0 0.8 1.8 17.0 488 12.1

2.5 1 / 1.78 1.78 0.8 1.0 0.8 1.8 17.5 551 7.41

2.5 7 / 0.67 2.01 0.8 1.0 0.8 1.8 18.0 572 7.41

4 1 / 2.26 2.26 1.0 1.0 0.8 1.8 20.5 835 4.61

4 7 / 0.85 2.55 1.0 1.0 1.25 1.8 21.5 865 4.61

6 7 / 1.04 3.12 1.0 1.0 1.25 1.8 22.5 1021 3.08

10 7 / 1.35 4.05 1.0 1.0 1.6 1.8 26.5 1479 1.83

16 7 / 1.70 5.10 1.0 1.0 1.60 1.8 29.0 1893 1.15

25 7 / 2.13 6.39 1.2 1.0 1.6 1.9 33.5 2577 0.727

35 7 / 2.52 7.56 1.2 1.0 2.0 2.0 38.0 3468 0.524

50 19 / 1.83 9.15 1.4 1.2 2.0 2.2 44.0 4503 0.387

/kmmm mm mm mm

(approx.)

mm² No./mm mm mm kg/km

Sheath cable cable at 20°C

area (approx.) (approx.) (approx.) (approx.)

of of of Resistance

section of wire Conductor Insulation covering Steel wire

Thickness diameter Weight Conductor

Cross- Diameter of of of Inner of Galv.

Nominal No./ Diameter Thickness Thickness Diameter

PVC/SWA/PVC (IEC 60502-1)

Conductor Nominal Nominal Overall MaximumNominal

600/1000 V PVC INSULATED, STEEL WIRE ARMOURED AND PVC SHEATHED CABLES

Page - 39

Page 42: LV2009

Section 2 - PVC Insulated Cables Armoured Cables

Constructions : Constructions :Conductor (Annealed Copper)Insulation (PVC Compound)Filler (Polyprophylene yarn,or extruded filler up to request)Inner Covering (PVC Compound)Galvanized Flat Steel Wire armourGalvanized Steel Tape bindingOuter sheath (PVC Compound)

600/1000 V PVC INSULATED, FLAT STEEL WIRE ARMOURED AND PVC SHEATHED CABLESPVC/FSWA/PVC (acc. to IEC 60502-1)

Page - 40

1

2

34

5

6

7

8

123

4567

Note : Special application upon request* Available product in accordance to : SPLN, ICEA/NEMA,

AS standard or other requirement.* Flame retardant test acc to IEC 60332-3 Cat. A, B or C.* Anti termite performance.* Tin coated Copper conductor.* Polyethylene / Low smoke Halogen Free sheathed

Page 43: LV2009

Section 2 - PVC Insulated CablesArmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Inner covering : PVC Compound Armour : Galvanized Flat Steel Wire+Steel tape open helix Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Red,Black

Sheath - Black

TWO CORES

1.5 1 / 1.38 1.38 0.8 1.0 0.8 0.3 1.8 14.0 406 12.1

1.5 7 / 0.52 1.56 0.8 1.0 0.8 0.3 1.8 14.5 417 12.1

2.5 1 / 1.78 1.78 0.8 1.0 0.8 0.3 1.8 15.0 442 7.41

2.5 7 / 0.67 2.01 0.8 1.0 0.8 0.3 1.8 15.5 480 7.41

4 1 / 2.26 2.26 1.0 1.0 0.8 0.3 1.8 17.0 569 4.61

4 7 / 0.85 2.55 1.0 1.0 0.8 0.3 1.8 17.5 584 4.61

6 7 / 1.04 3.12 1.0 1.0 0.8 0.3 1.8 18.5 674 3.08

10 7 / 1.35 4.05 1.0 1.0 0.8 0.3 1.8 20.5 826 1.83

16 7 / 1.70 5.10 1.0 1.0 0.8 0.3 1.8 22.5 1040 1.15

25 7 / 2.13 6.39 1.2 1.0 0.8 0.3 1.8 26.0 1365 0.727

35 7 / 2.52 7.56 1.2 1.0 0.8 0.3 1.8 28.0 1672 0.524

50 19 / 1.83 9.15 1.4 1.0 0.8 0.3 1.8 32.0 2134 0.387

70 19 / 2.17 10.85 1.4 1.0 0.8 0.3 1.9 35.5 2691 0.268

95 19 / 2.52 12.60 1.6 1.2 0.8 0.3 2.1 41.0 3484 0.193

120 37 / 2.03 14.21 1.6 1.2 0.8 0.3 2.2 44.5 4149 0.153

150 37 / 2.27 15.89 1.8 1.2 0.8 0.3 2.3 49.0 4995 0.124

185 37 / 2.52 17.64 2.0 1.4 0.8 0.3 2.4 53.5 5968 0.0991

240 61 / 2.26 20.34 2.2 1.4 0.8 0.3 2.6 60.0 7540 0.0754

300 61 / 2.52 22.68 2.4 1.6 0.8 0.3 2.8 66.5 9178 0.0601

Minimumthicknessof Galv.

Steel tapemm

of Innercovering(approx.)

thicknessof Galv.

FlatSteel wire

mm mm mm kg/kmmmmm

of section of wire Conductor

mm² No./mm mmarea (approx.) (approx.)

Maximum

(approx.)Insulation

ConductorCross- Diameter of of of of

Nominal No./ Diameter ThicknessOverall

Thickness Weightdiameter

cable cable at 20°C(approx.)

/km

Resistance

Conductor Nominal Nominal

600/1000 V PVC INSULATED, FLAT STEEL WIRE ARMOURED AND PVC SHEATHED CABLESPVC/FSWA/PVC (IEC 60502-1)

Thickness

Sheath

Nominal

Page - 41

Page 44: LV2009

Section 2 - PVC Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Inner covering : PVC Compound Armour : Galvanized Flat Steel Wire+Steel tape open helix Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Red,Yellow, Blue

Sheath - Black

THREE CORES

1.5 1 / 1.38 1.38 0.8 1.0 0.8 0.3 1.8 14.5 437 12.1

1.5 7 / 0.52 1.56 0.8 1.0 0.8 0.3 1.8 15.0 447 12.1

2.5 1 / 1.78 1.78 0.8 1.0 0.8 0.3 1.8 15.5 509 7.41

2.5 7 / 0.67 2.01 0.8 1.0 0.8 0.3 1.8 16.0 524 7.41

4 1 / 2.26 2.26 1.0 1.0 0.8 0.3 1.8 17.5 631 4.61

4 7 / 0.85 2.55 1.0 1.0 0.8 0.3 1.8 18.0 649 4.61

6 7 / 1.04 3.12 1.0 1.0 0.8 0.3 1.8 19.0 760 3.08

10 7 / 1.35 4.05 1.0 1.0 0.8 0.3 1.8 21.5 982 1.83

16 7 / 1.70 5.10 1.0 1.0 0.8 0.3 1.8 23.5 1230 1.15

25 7 / 2.13 6.39 1.2 1.0 0.8 0.3 1.8 27.0 1685 0.727

35 7 / 2.52 7.56 1.2 1.0 0.8 0.3 1.8 30.0 2089 0.524

50 6.8 1.4 1.0 0.8 0.3 1.9 28.5 2385 0.387

70 8.2 1.4 1.2 0.8 0.3 2.0 32.0 3149 0.268

95 9.7 1.6 1.2 0.8 0.3 2.2 37.0 4184 0.193

120 10.9 1.6 1.2 0.8 0.3 2.3 39.5 4902 0.153

150 11.9 1.8 1.4 0.8 0.3 2.4 43.0 5887 0.124

185 13.6 2.0 1.4 0.8 0.3 2.6 47.5 7212 0.0991

240 15.8 2.2 1.6 0.8 0.3 2.8 54.0 9457 0.0754

300 17.5 2.4 1.6 0.8 0.3 2.9 58.5 11517 0.0601

Minimumthicknessof Galv.

/km

Sector Shape

mm mm mm(approx.)

mm² No./mm mm mm mm mm kg/kmarea (approx.) (approx.) (approx.)

Sheath cablecovering Flat(approx.) Steel wire Steel tape

cable at 20°C

Conductor Nominal Nominal OverallThickness thickness

of Inner

MaximumThickness diameter Weight ConductorNominal No./ Diameter Thickness

of ResistanceCross- Diameter of of of Galv.section of wire Conductor Insulation

of of

600/1000 V PVC INSULATED, FLAT STEEL WIRE ARMOURED AND PVC SHEATHED CABLESPVC/FSWA/PVC (IEC 60502-1)

Nominal

Page - 42

stranded

Page 45: LV2009

Section 2 - PVC Insulated CablesArmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Inner covering : PVC Compound Armour : Galvanized Flat Steel Wire+Steel tape open helix Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Red,Yellow, Blue, Black

Sheath - Black

FOUR CORES

1.5 1 / 1.38 1.38 0.8 1.0 0.8 0.3 1.8 15.5 497 12.1

1.5 7 / 0.52 1.56 0.8 1.0 0.8 0.3 1.8 16.0 510 12.1

2.5 1 / 1.78 1.78 0.8 1.0 0.8 0.3 1.8 16.5 560 7.41

2.5 7 / 0.67 2.01 0.8 1.0 0.8 0.3 1.8 17.0 602 7.41

4 1 / 2.26 2.26 1.0 1.0 0.8 0.3 1.8 18.5 731 4.61

4 7 / 0.85 2.55 1.0 1.0 0.8 0.3 1.8 19.5 754 4.61

6 7 / 1.04 3.12 1.0 1.0 0.8 0.3 1.8 20.5 890 3.08

10 7 / 1.35 4.05 1.0 1.0 0.8 0.3 1.8 23.0 1157 1.83

16 7 / 1.70 5.10 1.0 1.0 0.8 0.3 1.8 25.5 1498 1.15

25 7 / 2.13 6.39 1.2 1.0 0.8 0.3 1.8 29.5 2055 0.727

35 7 / 2.52 7.56 1.2 1.0 0.8 0.3 1.9 32.5 2567 0.524

50 8.1 1.4 1.2 0.8 0.3 2.0 32.5 3041 0.387

70 9.7 1.4 1.2 0.8 0.3 2.1 36.0 3991 0.268

95 11.4 1.6 1.2 0.8 0.3 2.3 41.5 5307 0.193

120 12.9 1.6 1.4 0.8 0.3 2.4 45.0 6286 0.153

150 14.2 1.8 1.4 0.8 0.3 2.6 49.0 7567 0.124

185 16.0 2.0 1.6 0.8 0.3 2.7 54.5 9306 0.0991

240 18.2 2.2 1.6 0.8 0.3 3.0 60.5 12117 0.0754

300 20.6 2.4 1.6 0.8 0.3 3.2 66.5 14861 0.0601

600/1000 V PVC INSULATED, FLAT STEEL WIRE ARMOURED AND PVC SHEATHED CABLESPVC/FSWA/PVC (IEC 60502-1)

Conductor NominalMinimumthicknessof Galv.

Steel tape

Nominal Overall MaximumThickness diameter Weight ConductorNominal No./ Diameter Thickness Thickness thickness

of ResistanceCross- Diameter of of of Inner of Galv.

mm mmmm² No./mm

of of

area (approx.) (approx.) (approx.)section of wire Conductor Insulation

Sector Shape

mm mm

cable(approx.)

cableFlat Sheath

mm

covering

mm /kmkg/km

Nominal

mm

at 20°C

Page - 43

stranded

(approx.) Steel wire

Page 46: LV2009

Section 2 - PVC Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Inner covering : PVC Compound Armour : Galvanized Flat Steel Wire+Steel tape open helix Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Black with numbering code

Sheath - Black

FIVE CORES

1.5 1 / 1.38 1.38 0.8 1.0 0.8 0.3 1.8 16.5 538 12.1

1.5 7 / 0.52 1.56 0.8 1.0 0.8 0.3 1.8 17.0 580 12.1

2.5 1 / 1.78 1.78 0.8 1.0 0.8 0.3 1.8 17.5 635 7.41

2.5 7 / 0.67 2.01 0.8 1.0 0.8 0.3 1.8 18.0 654 7.41

4 1 / 2.26 2.26 1.0 1.0 0.8 0.3 1.8 20.0 832 4.61

4 7 / 0.85 2.55 1.0 1.0 0.8 0.3 1.8 21.0 860 4.61

6 7 / 1.04 3.12 1.0 1.0 0.8 0.3 1.8 22.0 1022 3.08

10 7 / 1.35 4.05 1.0 1.0 0.8 0.3 1.8 25.0 1338 1.83

16 7 / 1.70 5.10 1.0 1.0 0.8 0.3 1.8 27.5 1745 1.15

25 7 / 2.13 6.39 1.2 1.0 0.8 0.3 1.8 32.0 2413 0.727

35 7 / 2.52 7.56 1.2 1.0 0.8 0.3 1.9 35.5 3066 0.524

50 19 / 1.83 9.15 1.4 1.2 0.8 0.3 2.1 41.5 4013 0.387

thicknessof Galv.

Steel tapemm kg/km /km

(approx.) (approx.)mm² No./mm mm mm mm mm mm mm

Flat Sheath cable cable at 20°Carea (approx.) (approx.) (approx.) Steel wire

of Galv. of of of Resistancesection of wire Conductor Insulation covering

Thickness diameterMinimum Weight ConductorCross- Diameter of of of Inner

Nominal No./ Diameter Thickness Thickness thickness

PVC/FSWA/PVC (IEC 60502-1)

Conductor Nominal Nominal Overall MaximumNominal

600/1000 V PVC INSULATED, FLAT STEEL WIRE ARMOURED AND PVC SHEATHED CABLES

Page - 44

Page 47: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED, ALUMINIUM TAPE ARMOURED AND PVC SHEATHED CABLES

Constructions :

Conductor (Annealed Copper)

Insulation (PVC Compound)

Inner Covering (PVC Compound)

Outer sheath (PVC Compound)

600/1000 V PVC INSULATED, STEEL TAPE ARMOURED AND PVC SHEATHED CABLES

Constructions :

Conductor (Annealed Copper)

Insulation (PVC Compound)

up to request)

Binding tape (Manufacturer's option)

Inner Covering (PVC Compound)

Outer sheath (PVC Compound)

Page - 45

Armoured Cables

PVC/DATA/PVC (acc. to IEC 60502-1)

Double Aluminium Tape armour

PVC/DSTA/PVC (acc. to IEC 60502-1)

Filler (Polyprophylene yarn,or extruded filler

Double Galvanized Steel Tape armour

11

2

3

5

4

6

7

2

3

4

5

6

7

1

2

3

4

5

1

2

3

4

5

Note : Special application upon request* Available product in accordance to : SPLN, ICEA/NEMA,

AS standard or other requirement.* Flame retardant test acc to IEC 60332-3 Cat. A, B or C.* Anti termite performance.* Tin coated Copper conductor.* Polyethylene / Low smoke Halogen Free sheathed

Page 48: LV2009

Section 2 - PVC Insulated Cables

600/1000 V PVC INSULATED, ALUMINIUM TAPE ARMOURED AND PVC SHEATHED CABLES

PVC/DATA/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2)

Insulation : PVC Compound type A Operating Temperature

Inner covering : PVC Compound Maximum 70°C

Armour

Sheath : PVC Compound type ST1

: Insulation - Black

Sheath - Black

SINGLE CORE

Conductor Nominal Nominal Overall Maximum

Nominal No./ Diameter Thickness Thickness Nominal Thickness diameter Weight Conductor

Cross- Diameter of of of Inner thickness of of of of Resistance

section of wire Conductor Insulation covering Sheath cable cable at 20°C

area (approx.) (approx.) (approx.) tape (approx.) (approx.)

mm² No./mm mm mm mm mm mm mm kg/km

50 19 / 1.83 9.15 1.4 1.0 0.5 1.8 19.5 817 0.39

70 19 / 2.17 10.85 1.4 1.0 0.5 1.8 21.0 1045 0.27

95 19 / 2.52 12.60 1.6 1.0 0.5 1.8 23.5 1344 0.19

120 37 / 2.03 14.21 1.6 1.0 0.5 1.8 25.0 1607 0.15

150 37 / 2.27 15.89 1.8 1.0 0.5 1.8 27.0 1949 0.12

185 37 / 2.52 17.64 2.0 1.0 0.5 1.8 29.5 2339 0.1

240 61 / 2.26 20.34 2.2 1.0 0.5 1.9 32.5 2987 0.08

300 61 / 2.52 22.68 2.4 1.0 0.5 1.9 35.0 3628 0.06

400 61 / 2.86 25.74 2.6 1.2 0.5 2.1 39.5 4638 0.0470

500 61 / 3.20 28.80 2.8 1.2 0.5 2.2 43.5 5694 0.04

Page - 46

Armoured Cables

Uo/U - 600/1000 V

: Double Aluminium tape

Colour Ident.

Aluminium

W/km

Page 49: LV2009

Section 2 - PVC Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Inner covering : PVC Compound Armour : Double Galvanized Steel tape Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Red,Black

Sheath - Black

TWO CORES

1 / 1.38 1.38 0.8 1.0 0.2 1.8 13.0 237 12.1

7 / 0.52 1.56 0.8 1.0 0.2 1.8 13.0 250 12.1

1 / 1.78 1.78 0.8 1.0 0.2 1.8 13.5 276 7.41

7 / 0.67 2.01 0.8 1.0 0.2 1.8 14.0 290 7.41

1 / 2.26 2.26 1.0 1.0 0.2 1.8 15.5 357 4.61

7 / 0.85 2.55 1.0 1.0 0.2 1.8 16.0 374 4.61

7 / 1.04 3.12 1.0 1.0 0.2 1.8 17.0 440 3.08

10 7 / 1.35 4.05 1.0 1.0 0.2 1.8 19.0 574 1.83

16 7 / 1.70 5.10 1.0 1.0 0.2 1.8 21.0 742 1.15

25 7 / 2.13 6.39 1.2 1.0 0.2 1.8 24.5 1026 0.727

35 7 / 2.52 7.56 1.2 1.0 0.2 1.8 27.0 1290 0.524

50 19 / 1.83 9.15 1.4 1.0 0.2 1.8 31.0 1712 0.387

70 19 / 2.17 10.85 1.4 1.0 0.2 1.9 34.0 2262 0.268

95 19 / 2.52 12.60 1.6 1.2 0.2 2.1 39.0 2896 0.193

120 37 / 2.03 14.21 1.6 1.2 0.5 2.2 43.5 3921 0.153

150 37 / 2.27 15.89 1.8 1.2 0.5 2.3 48.0 4722 0.124

185 37 / 2.52 17.64 2.0 1.4 0.5 2.4 52.5 5675 0.0991

240 61 / 2.26 20.34 2.2 1.4 0.5 2.6 58.5 7166 0.0754

300 61 / 2.52 22.68 2.4 1.6 0.5 2.8 64.5 8710 0.0601

1.5

2.5

4

1.5

2.5

4

6

Thicknessof Innercovering(approx.)

Thicknessof Galv.

Steel tape

mm mm mm kg/kmmmmmmm² No./mm mmarea (approx.) (approx.)

of of of section of wire ConductorCross- Diameter of of

Maximum

(approx.)

Weightdiameter

cable cable at 20°C(approx.)

Conductor

/km

Resistance

Conductor Nominal NominalNominal No./ Diameter Thickness

Overall

Insulation

600/1000 V PVC INSULATED, STEEL TAPE ARMOURED AND PVC SHEATHED CABLESPVC/DSTA/PVC (IEC 60502-1)

Thickness

Sheath

Nominal

Page - 47

Page 50: LV2009

Section 2 - PVC Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Inner covering : PVC Compound Armour : Double Galvanized Steel tape Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Red,Yellow, Blue

Sheath - Black

THREE CORES

1 / 1.38 1.38 0.8 1.0 0.2 1.8 13.5 270 12.1

7 / 0.52 1.56 0.8 1.0 0.2 1.8 13.5 281 12.1

1 / 1.78 1.78 0.8 1.0 0.2 1.8 14.0 318 7.41

7 / 0.67 2.01 0.8 1.0 0.2 1.8 14.5 335 7.41

1 / 2.26 2.26 1.0 1.0 0.2 1.8 16.0 420 4.61

7 / 0.85 2.55 1.0 1.0 0.2 1.8 16.5 441 4.61

7 / 1.04 3.12 1.0 1.0 0.2 1.8 18.0 530 3.08

10 7 / 1.35 4.05 1.0 1.0 0.2 1.8 20.0 707 1.83

16 7 / 1.70 5.10 1.0 1.0 0.2 1.8 22.0 935 1.15

25 7 / 2.13 6.39 1.2 1.0 0.2 1.8 26.0 1328 0.727

35 7 / 2.52 7.56 1.2 1.0 0.2 1.8 28.5 1685 0.524

50 6.8 1.4 1.0 0.2 1.9 27.0 2002 0.387

70 8.2 1.4 1.2 0.2 2.0 30.5 2724 0.268

95 9.7 1.6 1.2 0.5 2.2 36.5 4062 0.193

120 10.9 1.6 1.2 0.5 2.3 39.5 4765 0.153

150 11.9 1.8 1.4 0.5 2.4 42.5 5745 0.124

185 13.6 2.0 1.4 0.5 2.6 47.5 7055 0.0991

240 15.8 2.2 1.6 0.5 2.8 53.5 9254 0.0754

300 17.5 2.4 1.6 0.5 2.9 58.0 11299 0.0601

1.5

2.5

mm² No./mm

Three-

Segmental

Stranded

1.5

2.5

4

6

4

Thickness Thicknessof Inner of Galv.

area (approx.) (approx.)/kmmm mm

(approx.)mm mm kg/km

Sheath cablecovering Steel tape

mm mm(approx.)(approx.)

cable at 20°C

Conductor Nominal Nominal Overall Maximum

Cross-Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

of Resistancesection of wire Conductor Insulation

Diameter of of of of

600/1000 V PVC INSULATED, STEEL TAPE ARMOURED AND PVC SHEATHED CABLESPVC/DSTA/PVC (IEC 60502-1)

Nominal

Page - 48

Page 51: LV2009

Section 2 - PVC Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Inner covering : PVC Compound Armour : Double Galvanized Steel tape Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Red,Yellow, Blue, Black

Sheath - Black

FOUR CORES

1 / 1.38 1.38 0.8 1.0 0.2 1.8 14.0 307 12.1

7 / 0.52 1.56 0.8 1.0 0.2 1.8 14.5 322 12.1

1 / 1.78 1.78 0.8 1.0 0.2 1.8 15.0 372 7.41

7 / 0.67 2.01 0.8 1.0 0.2 1.8 15.5 390 7.41

1 / 2.26 2.26 1.0 1.0 0.2 1.8 17.5 499 4.61

7 / 0.85 2.55 1.0 1.0 0.2 1.8 18.0 524 4.61

7 / 1.04 3.12 1.0 1.0 0.2 1.8 19.0 638 3.08

10 7 / 1.35 4.05 1.0 1.0 0.2 1.8 21.5 860 1.83

16 7 / 1.70 5.10 1.0 1.0 0.2 1.8 24.0 1158 1.15

25 7 / 2.13 6.39 1.2 1.0 0.2 1.8 28.0 1650 0.727

35 7 / 2.52 7.56 1.2 1.0 0.2 1.8 31.0 2120 0.524

50 8.1 1.4 1.2 0.2 2.0 31.0 2592 0.387

70 9.7 1.4 1.2 0.5 2.1 36.0 3862 0.268

95 11.4 1.6 1.2 0.5 2.3 41.0 5171 0.193

120 12.9 1.6 1.4 0.5 2.4 44.5 6122 0.153

150 14.2 1.8 1.4 0.5 2.6 49.0 7405 0.124

185 16.0 2.0 1.6 0.5 2.7 54.0 9113 0.0991

240 18.2 2.2 1.6 0.5 3.0 60.0 11899 0.0754

300 20.6 2.4 1.6 0.5 3.2 66.5 14624 0.0601

1.5

4

2.5

Segmental

Stranded

Four-

600/1000 V PVC INSULATED, STEEL TAPE ARMOURED AND PVC SHEATHED CABLESPVC/DSTA/PVC (IEC 60502-1)

ConductorThickness

Cross-section

Thicknessof Inner of Galv.

Nominal Overall MaximumNominal No./ Diameter Thickness Thickness diameter Weight Conductor

Nominal

Resistancecable at 20°C

Diameter of of ofof wire Conductor Insulation covering

of of Steel tape

(approx.) (approx.)Sheath cable

(approx.) (approx.)mm² No./mm mm mm mm mm kg/kmarea (approx.)

/kmmm mm

1.5

2.5

4

6

Nominal

Page - 49

Page 52: LV2009

Section 2 - PVC Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : PVC Compound type A Operating Temperature Filler : Suitable material Maximum 70°C Inner covering : PVC Compound Armour : Double Galvanized Steel tape Sheath : PVC Compound type ST1 Colour Ident. : Insulation - Black with numbering code

Sheath - Black

FIVE CORES

1 / 1.38 1.38 0.8 1.0 0.2 1.8 15.0 350 12.1

7 / 0.52 1.56 0.8 1.0 0.2 1.8 15.5 368 12.1

1 / 1.78 1.78 0.8 1.0 0.2 1.8 16.0 424 7.41

7 / 0.67 2.01 0.8 1.0 0.2 1.8 16.5 446 7.41

1 / 2.26 2.26 1.0 1.0 0.2 1.8 18.5 578 4.61

7 / 0.85 2.55 1.0 1.0 0.2 1.8 19.5 609 4.61

7 / 1.04 3.12 1.0 1.0 0.2 1.8 20.5 748 3.08

10 7 / 1.35 4.05 1.0 1.0 0.2 1.8 23.5 1022 1.83

16 7 / 1.70 5.10 1.0 1.0 0.2 1.8 26.0 1386 1.15

25 7 / 2.13 6.39 1.2 1.0 0.2 1.8 30.5 1991 0.727

35 7 / 2.52 7.56 1.2 1.0 0.2 1.9 34.0 2577 0.524

50 19 / 1.83 9.15 1.4 1.2 0.2 2.1 40.0 3400 0.387

1.5

4

2.5

1.5

2.5

mm²area

4

6

Nominal Maximum

600/1000 V PVC INSULATED, STEEL TAPE ARMOURED AND PVC SHEATHED CABLES

Thickness Thickness diameter WeightNo./ Diameter Thickness Thickness ConductorCross- Diameter of of of Inner of Galv. of of of Resistancesection of wire Conductor Insulation covering Steel tape Sheath cable cable

kg/km

at 20°C(approx.) (approx.)(approx.) (approx.) (approx.)

mm mm

Nominal

PVC/DSTA/PVC (IEC 60502-1)

Conductor Nominal Nominal Overall

Page - 50

/kmmm mm mm mmNo./mm

Page 53: LV2009

Section 3 - XLPE Insulated Cables Unarmoured Cables

Constructions :Conductor (Annealed Copper)Insulation (XLPE Compound)Filler (Polyprophylene yarn,or extruded fillerup to request)Binding tape (Manufacturer's option)Outer sheath (PVC Compound)

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLESXLPE/PVC (IEC 60502-1)

Page - 51

1

2

3

4

5

123

45

2

Note : Special application upon request* Available product in accordance to : SPLN, ICEA/NEMA,

AS standard or other requirement.* Flame retardant test acc to IEC 60332-3 Cat. A, B or C.* Anti termite performance.* Tin coated Copper conductor.* Polyethylene / Low smoke Halogen Free sheathed

Page 54: LV2009

Section 3 - XLPE Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Sheath : PVC Compound type ST2 Maximum 90°C Colour Ident. : Insulation - Black

Sheath - Black

SINGLE CORE

1.5 1 / 1.38 1.38 0.7 1.4 6.0 49 12.1

1.5 7 / 0.52 1.56 0.7 1.4 6.5 51 12.1

2.5 1 / 1.78 1.78 0.7 1.4 6.5 62 7.41

2.5 7 / 0.67 2.01 0.7 1.4 7.0 64 7.41

4 1 / 2.26 2.26 0.7 1.4 7.0 80 4.61

4 7 / 0.85 2.55 0.7 1.4 7.5 83 4.61

6 7 / 1.04 3.12 0.7 1.4 8.0 106 3.08

10 7 / 1.35 4.05 0.7 1.4 9.0 152 1.83

16 4.7 0.7 1.4 9.5 206 1.15

25 5.9 0.9 1.4 11.0 302 0.727

35 7.1 0.9 1.4 12.0 399 0.524

50 8.1 1.0 1.4 13.5 518 0.387

70 9.7 1.1 1.4 15.0 721 0.268

95 11.6 1.1 1.5 17.5 979 0.193

120 12.9 1.2 1.5 19.0 1212 0.153

150 14.3 1.4 1.6 21.0 1502 0.124

185 16.0 1.6 1.6 23.0 1854 0.0991

240 18.3 1.7 1.7 26.0 2406 0.0754

300 20.7 1.8 1.8 28.5 2996 0.0601

400 23.4 2.0 1.9 32.0 3799 0.0470

500 26.5 2.2 2.0 35.5 4842 0.0366

630 30.3 2.4 2.2 40.0 6233 0.0283

800 34.3 2.6 2.3 45.0 7933 0.0221

1000 127 / 3.2 41.6 2.8 2.4 53.0 10109 0.0176

Page - 52

area (approx.)

kg/km /kmmm

Compact

Resistance

(approx.) (approx.)

mm² No./mm mm

section of wire Conductor

Cross- Diameter of of

Insulation

of

Conductor Nominal Nominal Overall

Nominal No./ Diameter Thickness diameter

Sheath cable

Maximum

Weight Conductor

of of

round

stranded

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLESXLPE/PVC (IEC 60502-1)

cable at 20°C

(approx.)

mmmm

Thickness

Page 55: LV2009

Section 3 - XLPE Insulated Cables

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLES

XLPE/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2)

Insulation : XLPE Compound Operating Temperature

Filler : Suitable material Maximum 90°C

Sheath : PVC Compound type ST2

: Insulation - Red,Black

Sheath - Black

TWO CORES

Conductor Nominal Nominal Overall Maximum

Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

Cross- Diameter of of of of of Resistance

section of wire Conductor Insulation Sheath cable cable at 20°C

area (approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

1.5 1 / 1.38 1.38 0.7 1.8 10.0 110 12.1

1.5 7 / 0.52 1.56 0.7 1.8 10.5 120 12.1

2.5 1 / 1.78 1.78 0.7 1.8 10.5 140 7.41

2.5 7 / 0.67 2.01 0.7 1.8 11.0 145 7.41

4 1 / 2.26 2.26 0.7 1.8 11.5 180 4.61

4 7 / 0.85 2.55 0.7 1.8 12.5 190 4.61

6 7 / 1.04 3.12 0.7 1.8 13.5 240 3.08

10 7 / 1.35 4.05 0.7 1.8 15.5 345 1.83

16 4.7 0.7 1.8 16.5 460 1.15

25 5.9 0.9 1.8 19.5 675 0.73

35 Compact 7.1 0.9 1.8 22.0 890 0.52

50 round 8.1 1.0 1.8 24.5 1150 0.39

70 stranded 9.7 1.1 1.8 28.0 1595 0.27

95 11.6 1.1 2.0 32.5 2170 0.19

120 12.9 1.2 2.1 35.5 2695 0.15

150 14.3 1.4 2.2 39.5 3330 0.12

185 16.0 1.6 2.3 44.0 4135 0.1

240 18.3 1.7 2.5 49.5 5360 0.08

300 20.7 1.8 2.7 55.0 6680 0.06

400 23.4 2.0 2.9 61.5 8465 0.0470

Page - 53

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 56: LV2009

Section 3 - XLPE Insulated Cables

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLES

XLPE/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2)

Insulation : XLPE Compound Operating Temperature

Filler : Suitable material Maximum 90°C

Sheath : PVC Compound type ST2

: Insulation - Red,Yellow, Blue

Sheath - Black

THREE CORES

Conductor Nominal Nominal Overall Maximum

Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

Cross- Diameter of of of of of Resistance

section of wire Conductor Insulation Sheath cable cable at 20°C

area (approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

1.5 1 / 1.38 1.38 0.7 1.8 10.5 135 12.1

1.5 7 / 0.52 1.56 0.7 1.8 11.0 140 12.1

2.5 1 / 1.78 1.78 0.7 1.8 11.0 170 7.41

2.5 7 / 0.67 2.01 0.7 1.8 11.5 180 7.41

4 1 / 2.26 2.26 0.7 1.8 12.5 225 4.61

4 7 / 0.85 2.55 0.7 1.8 13.0 240 4.61

6 7 / 1.04 3.12 0.7 1.8 14.0 310 3.08

10 7 / 1.35 4.05 0.7 1.8 16.0 450 1.83

16 4.7 0.7 1.8 17.5 620 1.15

25 5.9 0.9 1.8 21.0 920 0.727

35 Compact 7.1 0.9 1.8 23.5 1220 0.524

50 round 8.1 1.0 1.8 26.0 1595 0.387

70 stranded 9.7 1.1 1.9 30.0 2240 0.268

95 11.6 1.1 2.0 34.5 3040 0.193

120 12.9 1.2 2.1 38.0 3790 0.153

150 14.3 1.4 2.3 42.0 4705 0.124

185 16.0 1.6 2.4 47.5 5845 0.0991

240 18.3 1.7 2.6 53.0 7595 0.0754

300 20.7 1.8 2.8 59.0 9470 0.0601

400 23.4 2.0 3.1 66.5 12055 0.0470

Page - 54

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 57: LV2009

Section 3 - XLPE Insulated Cables

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLES

XLPE/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2)

Insulation : XLPE Compound Operating Temperature

Filler : Suitable material Maximum 90°C

Sheath : PVC Compound type ST2

: Insulation - Red,Yellow, Blue, Black

Sheath - Black

FOUR CORES

Conductor Nominal Nominal Overall Maximum

Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

Cross- Diameter of of of of of Resistance

section of wire Conductor Insulation Sheath cable cable at 20°C

area (approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

1.5 1 / 1.38 1.38 0.7 1.8 11.0 160 12.1

1.5 7 / 0.52 1.56 0.7 1.8 11.5 165 12.1

2.5 1 / 1.78 1.78 0.7 1.8 12.0 210 7.41

2.5 7 / 0.67 2.01 0.7 1.8 12.5 220 7.41

4 1 / 2.26 2.26 0.7 1.8 13.5 280 4.61

4 7 / 0.85 2.55 0.7 1.8 14.0 290 4.61

6 7 / 1.04 3.12 0.7 1.8 15.0 385 3.08

10 7 / 1.35 4.05 0.7 1.8 17.5 570 1.83

16 4.7 0.7 1.8 19.0 790 1.15

25 5.9 0.9 1.8 23.0 1180 0.727

35 Compact 7.1 0.9 1.8 26.0 1575 0.524

50 round 8.1 1.0 1.9 29.0 2075 0.387

70 stranded 9.7 1.1 2.0 33.5 2925 0.268

95 11.6 1.1 2.1 38.5 3980 0.193

120 12.9 1.2 2.3 42.5 4980 0.153

150 14.3 1.4 2.4 47.0 6160 0.124

185 16.0 1.6 2.6 53.0 7680 0.0991

240 18.3 1.7 2.8 59.0 9975 0.0754

300 20.7 1.8 3.0 66.0 12440 0.0601

Page - 55

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 58: LV2009

Section 3 - XLPE Insulated Cables

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLES

XLPE/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2)

Insulation : XLPE Compound Operating Temperature

Filler : Suitable material Maximum 90°C

Sheath : PVC Compound type ST2

: Insulation - Black with numbering code

Sheath - Black

FIVE CORES

Conductor Nominal Nominal Overall Maximum

Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

Cross- Diameter of of of of of Resistance

section of wire Conductor Insulation Sheath cable cable at 20°C

area (approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

1.5 1 / 1.38 1.38 0.7 1.8 12.0 185 12.1

1.5 7 / 0.52 1.56 0.7 1.8 12.5 195 12.1

2.5 1 / 1.78 1.78 0.7 1.8 13.0 245 7.41

2.5 7 / 0.67 2.01 0.7 1.8 13.5 255 7.41

4 1 / 2.26 2.26 0.7 1.8 14.5 335 4.61

4 7 / 0.85 2.55 0.7 1.8 15.0 350 4.61

6 7 / 1.04 3.12 0.7 1.8 16.5 465 3.08

10 7 / 1.35 4.05 0.7 1.8 19.5 690 1.83

16 Compact 4.7 0.7 1.8 21.0 965 1.15

25 round 5.9 0.9 1.8 25.0 1450 0.727

35 stranded 7.1 0.9 1.8 28.5 1940 0.524

50 8.1 1.0 2.0 32.0 2575 0.387

Page - 56

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 59: LV2009

Section 3 - XLPE Insulated Cables

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLES

XLPE/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

Insulation : XLPE Compound Operating Temperature

Filler (if necessary): Suitable material Maximum 90°C

Sheath : PVC Compound type ST2

: Insulation - Black with numbering code

Sheath - Black

CONTROL CABLE : 1.5 mm² (Solid conductor)

Conductor Nominal Nominal Overall Maximum

No Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

of Cross-section Diameter of of of of of Resistance

core area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

6 1.5 1 / 1.38 1.38 0.7 1.8 13.0 210 12.1

7 1.5 1 / 1.38 1.38 0.7 1.8 13.0 225 12.1

8 1.5 1 / 1.38 1.38 0.7 1.8 14.0 250 12.1

9 1.5 1 / 1.38 1.38 0.7 1.8 14.5 280 12.1

10 1.5 1 / 1.38 1.38 0.7 1.8 16.0 310 12.1

12 1.5 1 / 1.38 1.38 0.7 1.8 16.5 350 12.1

14 1.5 1 / 1.38 1.38 0.7 1.8 17.0 395 12.1

15 1.5 1 / 1.38 1.38 0.7 1.8 17.5 415 12.1

16 1.5 1 / 1.38 1.38 0.7 1.8 18.0 440 12.1

18 1.5 1 / 1.38 1.38 0.7 1.8 19.0 480 12.1

19 1.5 1 / 1.38 1.38 0.7 1.8 19.0 495 12.1

20 1.5 1 / 1.38 1.38 0.7 1.8 19.5 520 12.1

24 1.5 1 / 1.38 1.38 0.7 1.8 22.0 620 12.1

30 1.5 1 / 1.38 1.38 0.7 1.8 23.0 740 12.1

32 1.5 1 / 1.38 1.38 0.7 1.8 23.5 780 12.1

37 1.5 1 / 1.38 1.38 0.7 1.8 25.0 880 12.1

40 1.5 1 / 1.38 1.38 0.7 1.8 26.0 945 12.1

50 1.5 1 / 1.38 1.38 0.7 1.9 28.5 1150 12.1

52 1.5 1 / 1.38 1.38 0.7 1.9 29.5 1210 12.1

60 1.5 1 / 1.38 1.38 0.7 1.9 31.0 1375 12.1

61 1.5 1 / 1.38 1.38 0.7 1.9 31.0 1390 12.1

Page - 57

Unarmoured Cables

(to IEC 60228 clas 1) Uo/U - 600/1000 V

Colour Ident.

W/km

Page 60: LV2009

Section 3 - XLPE Insulated Cables

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLES

XLPE/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

Insulation : XLPE Compound Operating Temperature

Filler (if necessary): Suitable material Maximum 90°C

Sheath : PVC Compound type ST2

: Insulation - Black with numbering code

Sheath - Black

CONTROL CABLE : 1.5 mm² (Stranded conductor)

Conductor Nominal Nominal Overall Maximum

No Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

of Cross-section Diameter of of of of of Resistance

core area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

6 1.5 7 / 0.52 1.56 0.7 1.8 13.5 220 12.1

7 1.5 7 / 0.52 1.56 0.7 1.8 13.5 235 12.1

8 1.5 7 / 0.52 1.56 0.7 1.8 14.5 265 12.1

9 1.5 7 / 0.52 1.56 0.7 1.8 15.5 295 12.1

10 1.5 7 / 0.52 1.56 0.7 1.8 16.5 325 12.1

12 1.5 7 / 0.52 1.56 0.7 1.8 17.0 365 12.1

14 1.5 7 / 0.52 1.56 0.7 1.8 18.0 415 12.1

15 1.5 7 / 0.52 1.56 0.7 1.8 18.5 435 12.1

16 1.5 7 / 0.52 1.56 0.7 1.8 19.0 460 12.1

18 1.5 7 / 0.52 1.56 0.7 1.8 20.0 505 12.1

19 1.5 7 / 0.52 1.56 0.7 1.8 20.0 520 12.1

20 1.5 7 / 0.52 1.56 0.7 1.8 20.5 545 12.1

24 1.5 7 / 0.52 1.56 0.7 1.8 23.0 650 12.1

30 1.5 7 / 0.52 1.56 0.7 1.8 24.5 775 12.1

32 1.5 7 / 0.52 1.56 0.7 1.8 25.0 815 12.1

37 1.5 7 / 0.52 1.56 0.7 1.8 26.5 920 12.1

40 1.5 7 / 0.52 1.56 0.7 1.8 27.5 990 12.1

50 1.5 7 / 0.52 1.56 0.7 1.9 30.0 1205 12.1

52 1.5 7 / 0.52 1.56 0.7 1.9 31.0 1265 12.1

60 1.5 7 / 0.52 1.56 0.7 1.9 33.0 1435 12.1

61 1.5 7 / 0.52 1.56 0.7 1.9 33.0 1455 12.1

Page - 58

Unarmoured Cables

(to IEC 60228 clas 2) Uo/U - 600/1000 V

Colour Ident.

W/km

Page 61: LV2009

Section 3 - XLPE Insulated Cables

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLES

XLPE/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1)

Insulation : XLPE Compound Operating Temperature

Filler (if necessary): Suitable material Maximum 90°C

Sheath : PVC Compound type ST2

: Insulation - Black with numbering code

Sheath - Black

CONTROL CABLE : 2.5 mm² (Solid conductor)

Conductor Nominal Nominal Overall Maximum

No Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

of Cross-section Diameter of of of of of Resistance

core area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

6 2.5 1 / 1.78 1.78 0.7 1.8 14.0 280 7.41

7 2.5 1 / 1.78 1.78 0.7 1.8 14.0 300 7.41

8 2.5 1 / 1.78 1.78 0.7 1.8 15.0 340 7.41

9 2.5 1 / 1.78 1.78 0.7 1.8 16.0 385 7.41

10 2.5 1 / 1.78 1.78 0.7 1.8 17.5 425 7.41

12 2.5 1 / 1.78 1.78 0.7 1.8 18.0 485 7.41

14 2.5 1 / 1.78 1.78 0.7 1.8 19.0 550 7.41

15 2.5 1 / 1.78 1.78 0.7 1.8 19.5 580 7.41

16 2.5 1 / 1.78 1.78 0.7 1.8 20.0 615 7.41

18 2.5 1 / 1.78 1.78 0.7 1.8 21.0 675 7.41

19 2.5 1 / 1.78 1.78 0.7 1.8 21.0 700 7.41

20 2.5 1 / 1.78 1.78 0.7 1.8 21.5 735 7.41

24 2.5 1 / 1.78 1.78 0.7 1.8 24.5 875 7.41

30 2.5 1 / 1.78 1.78 0.7 1.8 25.5 1055 7.41

32 2.5 1 / 1.78 1.78 0.7 1.8 26.0 1120 7.41

37 2.5 1 / 1.78 1.78 0.7 1.8 27.5 1265 7.41

40 2.5 1 / 1.78 1.78 0.7 1.9 29.0 1375 7.41

50 2.5 1 / 1.78 1.78 0.7 2.0 32.0 1685 7.41

52 2.5 1 / 1.78 1.78 0.7 2.0 33.0 1765 7.41

60 2.5 1 / 1.78 1.78 0.7 2.0 35.0 2010 7.41

61 2.5 1 / 1.78 1.78 0.7 2.0 35.0 2040 7.41

Page - 59

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 62: LV2009

Section 3 - XLPE Insulated Cables

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLES

XLPE/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2)

Insulation : XLPE Compound Operating Temperature

Filler (if necessary): Suitable material Maximum 90°C

Sheath : PVC Compound type ST2

: Insulation - Black with numbering code

Sheath - Black

CONTROL CABLE : 2.5 mm² (Stranded conductor)

Conductor Nominal Nominal Overall Maximum

No Nominal No./ Diameter Thickness Thickness diameter Weight Conductor

of Cross-section Diameter of of of of of Resistance

core area of wire Conductor Insulation Sheath cable cable at 20°C

(approx.) (approx.) (approx.) (approx.)

mm² No./mm mm mm mm mm kg/km

6 2.5 7 / 0.67 2.01 0.7 1.8 14.5 290 7.41

7 2.5 7 / 0.67 2.01 0.7 1.8 14.5 315 7.41

8 2.5 7 / 0.67 2.01 0.7 1.8 16.0 355 7.41

9 2.5 7 / 0.67 2.01 0.7 1.8 17.0 400 7.41

10 2.5 7 / 0.67 2.01 0.7 1.8 18.5 440 7.41

12 2.5 7 / 0.67 2.01 0.7 1.8 19.0 505 7.41

14 2.5 7 / 0.67 2.01 0.7 1.8 20.0 570 7.41

15 2.5 7 / 0.67 2.01 0.7 1.8 20.5 605 7.41

16 2.5 7 / 0.67 2.01 0.7 1.8 21.0 640 7.41

18 2.5 7 / 0.67 2.01 0.7 1.8 22.0 705 7.41

19 2.5 7 / 0.67 2.01 0.7 1.8 22.0 725 7.41

20 2.5 7 / 0.67 2.01 0.7 1.8 22.5 765 7.41

24 2.5 7 / 0.67 2.01 0.7 1.8 25.5 915 7.41

30 2.5 7 / 0.67 2.01 0.7 1.8 27.0 1100 7.41

32 2.5 7 / 0.67 2.01 0.7 1.8 27.5 1165 7.41

37 2.5 7 / 0.67 2.01 0.7 1.8 29.0 1315 7.41

40 2.5 7 / 0.67 2.01 0.7 1.9 30.5 1430 7.41

50 2.5 7 / 0.67 2.01 0.7 2.0 33.5 1755 7.41

52 2.5 7 / 0.67 2.01 0.7 2.0 34.5 1840 7.41

60 2.5 7 / 0.67 2.01 0.7 2.0 36.5 2095 7.41

61 2.5 7 / 0.67 2.01 0.7 2.0 36.5 2120 7.41

Page - 60

Unarmoured Cables

Uo/U - 600/1000 V

Colour Ident.

W/km

Page 63: LV2009

Section 3 - XLPE Insulated Cables Unarmoured Cables

Constructions :Conductor (Annealed Copper)Insulation (XLPE Compound)Filler (Polyprophylene yarn,or extruded fillerup to request)Binding tape (Manufacturer's option)Copper Tape screenBinding tape (Manufacturer's option)Outer sheath (PVC Compound)

600/1000 V XLPE INSULATED, METALLIC SCREENED AND PVC SHEATHED CABLESXLPE/PVC-S (IEC 60502-1)

Page - 61

1

2

3

6

7

4

123

4

567

5

Note : Special application upon request* Available product in accordance to : SPLN, ICEA/NEMA,

AS standard or other requirement.* Flame retardant test acc to IEC 60332-3 Cat. A, B or C.* Anti termite performance.* Tin coated Copper conductor.* Copper wire screen.* Polyethylene / Low smoke Halogen Free sheathed

Page 64: LV2009

Section 3 - XLPE Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Metallic screen : Annealed Copper tape Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Red,Black

Sheath - Black

TWO CORES

1.5 1 / 1.38 1.38 0.7 0.1 1.8 10.0 125 12.1

1.5 7 / 0.52 1.56 0.7 0.1 1.8 10.5 131 12.1

2.5 1 / 1.78 1.78 0.7 0.1 1.8 11.0 155 7.41

2.5 7 / 0.67 2.01 0.7 0.1 1.8 11.5 162 7.41

4 1 / 2.26 2.26 0.7 0.1 1.8 12.0 200 4.61

4 7 / 0.85 2.55 0.7 0.1 1.8 12.5 209 4.61

6 1 / 2.77 2.77 0.7 0.1 1.8 13.0 250 3.08

6 7 / 1.04 3.12 0.7 0.1 1.8 13.5 261 3.08

10 7 / 1.35 4.05 0.7 0.1 1.8 15.5 369 1.83

16 4.7 0.7 0.1 1.8 16.5 489 1.15

25 5.9 0.9 0.1 1.8 20.0 712 0.727

35 7.1 0.9 0.1 1.8 22.5 934 0.524

50 8.1 1.0 0.1 1.8 24.5 1196 0.387

70 9.7 1.1 0.1 1.9 28.5 1648 0.268

95 11.6 1.1 0.1 2.0 32.5 2226 0.193

120 12.9 1.2 0.1 2.1 35.5 2753 0.153

150 14.3 1.4 0.1 2.2 39.5 3394 0.124

185 16.0 1.6 0.1 2.3 44.0 4205 0.0991

240 18.3 1.7 0.1 2.5 49.5 5425 0.0754

300 20.7 1.8 0.1 2.7 55.0 6752 0.0601

400 23.4 2.0 0.1 2.9 61.5 8543 0.0470

round

mm

cable

kg/km

Page - 62

mm mm

Sheath

mm

Insulation

(approx.)

Copper tape

Resistance

(approx.)

at 20°Ccable

of

stranded

/km

Conductorsection area of wire

(approx.) (approx.)

mm² No./mm

Compact

600/1000 V XLPE INSULATED, METALLIC SCREENED AND PVC SHEATHED CABLES

Diameter

Nominal

Thickness

Overall

diameter

Conductor Maximum

Conductor

Nominal

No./

Diameter

Thickness

Nominal

Thickness

of ofof

mm

XLPE/PVC-S (IEC 60502-1)

Nominal Weight

ofofCross-

(approx.)

Page 65: LV2009

Section 3 - XLPE Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Metallic screen : Annealed Copper tape Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Red,Yellow , Blue

Sheath - Black

THREE CORES

1.5 1 / 1.38 1.38 0.7 0.1 1.8 10.5 149 12.1

1.5 7 / 0.52 1.56 0.7 0.1 1.8 11.0 155 12.1

2.5 1 / 1.78 1.78 0.7 0.1 1.8 11.5 186 7.41

2.5 7 / 0.67 2.01 0.7 0.1 1.8 12.0 195 7.41

4 1 / 2.26 2.26 0.7 0.1 1.8 12.5 246 4.61

4 7 / 0.85 2.55 0.7 0.1 1.8 13.0 257 4.61

6 1 / 2.77 2.77 0.7 0.1 1.8 13.5 318 3.08

6 7 / 1.04 3.12 0.7 0.1 1.8 14.0 330 3.08

10 7 / 1.35 4.05 0.7 0.1 1.8 16.5 478 1.83

16 4.7 0.7 0.1 1.8 17.5 650 1.15

25 5.9 0.9 0.1 1.8 21.0 959 0.727

35 7.1 0.9 0.1 1.8 23.5 1273 0.524

50 8.1 1.0 0.1 1.8 26.5 1642 0.387

70 9.7 1.1 0.1 1.9 30.0 2282 0.268

95 11.6 1.1 0.1 2.0 34.5 3106 0.193

120 12.9 1.2 0.1 2.2 38.0 3868 0.153

150 14.3 1.4 0.1 2.3 42.0 4775 0.124

185 16.0 1.6 0.1 2.4 47.0 5907 0.0991

240 18.3 1.7 0.1 2.6 53.0 7673 0.0754

300 20.7 1.8 0.1 2.8 59.0 9561 0.0601

400 23.4 2.0 0.1 3.1 66.0 12110 0.0470

Compact

(approx.)

mm

round

No./mm

stranded

(approx.) (approx.)

Thickness

of

Copper tape

(approx.)

cable

of

at 20°Csection area of wire Conductor Insulation Sheath cable

600/1000 V XLPE INSULATED, METALLIC SCREENED AND PVC SHEATHED CABLES

Cross- Diameter of of of Resistance

Nominal MaximumConductor Nominal

XLPE/PVC-S (IEC 60502-1)

Nominal Overall

mm²

(approx.)

Thickness diameterNo./ Diameter ThicknessNominal

mm /kmkg/kmmm mm

Weight Conductor

of

mm

Page - 63

Page 66: LV2009

Section 3 - XLPE Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Metallic screen : Annealed Copper tape Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Red,Yellow , Blue , Black

Sheath - Black

FOUR CORES

1.5 1 / 1.38 1.38 0.7 0.1 1.8 11.5 173 12.1

1.5 7 / 0.52 1.56 0.7 0.1 1.8 12.0 182 12.1

2.5 1 / 1.78 1.78 0.7 0.1 1.8 12.5 228 7.41

2.5 7 / 0.67 2.01 0.7 0.1 1.8 13.0 237 7.41

4 1 / 2.26 2.26 0.7 0.1 1.8 13.5 300 4.61

4 7 / 0.85 2.55 0.7 0.1 1.8 14.0 318 4.61

6 1 / 2.77 2.77 0.7 0.1 1.8 14.5 394 3.08

6 7 / 1.04 3.12 0.7 0.1 1.8 15.5 409 3.08

10 7 / 1.35 4.05 0.7 0.1 1.8 18.0 598 1.83

16 4.7 0.7 0.1 1.8 19.5 823 1.15

25 5.9 0.9 0.1 1.8 23.0 1227 0.727

35 7.1 0.9 0.1 1.8 26.0 1632 0.524

50 8.1 1.0 0.1 1.9 29.0 2120 0.387

70 9.7 1.1 0.1 2.0 33.5 2976 0.268

95 11.6 1.1 0.1 2.2 38.5 4073 0.193

120 12.9 1.2 0.1 2.3 42.5 5052 0.153

150 14.3 1.4 0.1 2.5 47.0 6243 0.124

185 16.0 1.6 0.1 2.6 52.5 7751 0.0991

240 18.3 1.7 0.1 2.8 59.0 10066 0.0754

300 20.7 1.8 0.1 3.0 65.5 12547 0.0601

400 23.4 2.0 0.1 3.3 73.5 15898 0.0470

Compact

round

stranded

(approx.)

Thickness

(approx.) (approx.) (approx.)

Conductor Nominal Nominal

of

Copper tape

diameterThickness Weight

cable

kg/km /kmmmmm² No./mm mm mm mmmm

Thickness

Resistance

at 20°Csection area of wire Conductor Insulation Sheath cable

Diameter of of of of of

600/1000 V XLPE INSULATED, METALLIC SCREENED AND PVC SHEATHED CABLESXLPE/PVC-S (IEC 60502-1)

Page - 64

No./ DiameterNominal

(approx.)

Overall MaximumNominal

Conductor

Cross-

Page 67: LV2009

Section 3 - XLPE Insulated Cables Unarmoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Metallic screen : Annealed Copper tape Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Black with numbering code

Sheath - Black

FIVE CORES

1.5 1 / 1.38 1.38 0.7 0.1 1.8 12.0 204 12.1

1.5 7 / 0.52 1.56 0.7 0.1 1.8 12.5 214 12.1

2.5 1 / 1.78 1.78 0.7 0.1 1.8 13.5 265 7.41

2.5 7 / 0.67 2.01 0.7 0.1 1.8 14.0 276 7.41

4 1 / 2.26 2.26 0.7 0.1 1.8 14.5 360 4.61

4 7 / 0.85 2.55 0.7 0.1 1.8 15.5 376 4.61

6 1 / 2.77 2.77 0.7 0.1 1.8 16.0 471 3.08

6 7 / 1.04 3.12 0.7 0.1 1.8 17.0 488 3.08

10 7 / 1.35 4.05 0.7 0.1 1.8 19.5 720 1.83

16 4.7 0.7 0.1 1.8 21.0 1005 1.15

25 5.9 0.9 0.1 1.8 25.5 1491 0.727

35 7.1 0.9 0.1 1.9 28.5 2005 0.524

50 8.1 1.0 0.1 2.0 32.0 2620 0.387

(approx.)

round

No./

(approx.)

600/1000 V XLPE INSULATED, METALLIC SCREENED AND PVC SHEATHED CABLESXLPE/PVC-S (IEC 60502-1)

Nominal

Compact

Copper tape

mm

Cross- Diameter of

Nominal

stranded

Conductor

mm² No./mm mm

cable at 20°C

of Resistance

Weight

of

Thickness

Overall Maximum

Conductor

Sheath cable

Thickness diameter

(approx.)

mm mm kg/km /kmmm

section area of wire Conductor Insulation

(approx.)

of

Diameter Thickness

Nominal Nominal

of of

Page - 65

(approx.)

Page 68: LV2009

Section 3 - XLPE Insulated Cables

600/1000 V XLPE INSULATED, ALUMINIUM WIRE ARMOURED AND PVC SHEATHED CABLES

Constructions :

Conductor (Annealed Copper)

Insulation (XLPE Compound)

Inner Covering (PVC Compound)

Binding tape (Manufacturer's option)

Outer sheath (PVC Compound)

600/1000 V XLPE INSULATED, STEEL WIRE ARMOURED AND PVC SHEATHED CABLES

Constructions :

Conductor (Annealed Copper)

Insulation (XLPE Compound)

up to request)

Binding tape (Manufacturer's option)

Inner Covering (PVC Compound)

Binding tape (Manufacturer's option)

Outer sheath (PVC Compound)

Page - 66

Armoured Cables

XLPE/AWA/PVC (acc. to IEC 60502-1)

Round Aluminium Wire armour

XLPE/SWA/PVC (acc. to IEC 60502-1)

Filler (Polyprophylene yarn,or extruded filler

Galvanized Round Steel Wire armour

1

2

3

4

5

6

7

1

2

3

4

5

1

2

3

4

6

1

2

3

5

4

6

7

88

6

5

Note : Special application upon request* Available product in accordance to : SPLN, ICEA/NEMA,

AS standard or other requirement.* Flame retardant test acc to IEC 60332-3 Cat. A, B or C.* Anti termite performance.* Tin coated Copper conductor.* Polyethylene / Low smoke Halogen Free sheathed

Page 69: LV2009

Section 3 - XLPE Insulated Cables

600/1000 V XLPE INSULATED, ALUMINIUM WIRE ARMOURED AND PVC SHEATHED CABLES

XLPE/AWA/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2)

Insulation : XLPE Compound Operating Temperature

Inner covering : PVC Compound Maximum 90°C

Armour

Sheath : PVC Compound type ST2

: Insulation - Black

Sheath - Black

SINGLE CORE

Conductor Nominal Nominal Overall Maximum

Nominal No./ Diameter Thickness Thickness Nominal Thickness diameter Weight Conductor

Cross- Diameter of of of Inner diameter of of of of Resistance

section of wire Conductor Insulation covering Sheath cable cable at 20°C

area (approx.) (approx.) (approx.) wire (approx.) (approx.)

mm² No./mm mm mm mm mm mm mm kg/km

16 4.7 0.7 1.0 0.8 1.8 13.5 325 1.15

25 5.9 0.9 1.0 0.8 1.8 15.5 435 0.73

35 7.1 0.9 1.0 0.8 1.8 16.5 545 0.52

50 8.1 1.0 1.0 1.25 1.8 18.5 715 0.39

70 9.7 1.1 1.0 1.25 1.8 20.0 940 0.27

95 11.6 1.1 1.0 1.25 1.8 22.0 1215 0.19

120 12.9 1.2 1.0 1.6 1.8 24.5 1565 0.15

150 Compact 14.3 1.4 1.0 1.6 1.8 26.5 1865 0.12

185 round 16.0 1.6 1.0 1.6 1.8 28.5 2270 0.1

240 stranded 18.3 1.7 1.0 1.6 1.9 31.0 2860 0.08

300 20.7 1.8 1.0 1.6 1.9 34.0 3490 0.06

400 23.4 2.0 1.2 2.0 2.1 38.5 4385 0.0470

500 26.5 2.2 1.2 2.0 2.2 42.0 5485 0.04

630 30.3 2.4 1.2 2.0 2.3 46.5 6930 0.03

800 34.3 2.6 1.4 2.5 2.5 52.5 8915 0.02

1000 Round stranded 41.6 2.8 1.4 2.5 2.5 60.5 11315 0.02

Page - 67

Armoured Cables

Uo/U - 600/1000 V

: Aluminium Wire

Colour Ident.

Aluminium

W/km

Page 70: LV2009

Section 3 - XLPE Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Inner covering : PVC Compound Armour : Galvanized Steel Wire Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Red,Black

Sheath - Black

TWO CORES

1.5 1 / 1.38 1.38 0.7 1.0 0.8 1.8 13.5 314 12.1

1.5 7 / 0.52 1.56 0.7 1.0 0.8 1.8 14.0 325 12.1

2.5 1 / 1.78 1.78 0.7 1.0 0.8 1.8 14.5 355 7.41

2.5 7 / 0.67 2.01 0.7 1.0 0.8 1.8 15.0 372 7.41

4 1 / 2.26 2.26 0.7 1.0 0.8 1.8 15.5 422 4.61

4 7 / 0.85 2.55 0.7 1.0 0.8 1.8 16.0 437 4.61

6 1 / 2.77 2.77 0.7 1.0 0.8 1.8 16.5 485 3.08

6 7 / 1.04 3.12 0.7 1.0 0.8 1.8 17.0 511 3.08

10 7 / 1.35 4.05 0.7 1.0 1.25 1.8 20.0 757 1.83

16 4.7 0.7 1.0 1.25 1.8 21.0 907 1.15

25 5.9 0.9 1.0 1.6 1.8 25.0 1342 0.727

35 7.1 0.9 1.0 1.6 1.8 27.5 1630 0.524

50 8.1 1.0 1.0 1.6 1.8 30.0 1965 0.387

70 9.7 1.1 1.0 1.6 2.0 34.0 2549 0.268

95 11.6 1.1 1.2 2.0 2.1 39.0 3517 0.193

120 12.9 1.2 1.2 2.0 2.2 42.0 4159 0.153

150 14.3 1.4 1.2 2.0 2.3 46.0 4966 0.124

185 16.0 1.6 1.4 2.5 2.5 52.0 6435 0.0991

240 18.3 1.7 1.4 2.5 2.7 57.5 7894 0.0754

300 20.7 1.8 1.6 2.5 2.8 63.0 9543 0.0601

of Inner

covering

(approx.)

Nominal

diameter

of

Steel wire

Compact

round

stranded

mm mm mm kg/kmmmmm

of

section of wire Conductor

mm² No./mm mm

area (approx.) (approx.)

Maximum

(approx.)

Insulation

Conductor

Cross- Diameter of of of of

Nominal No./ Diameter Thickness

Overall

Thickness Weightdiameter

cable cable at 20°C

(approx.)

/km

Resistance

600/1000 V XLPE INSULATED, STEEL WIRE ARMOURED AND PVC SHEATHED CABLESXLPE/SWA/PVC (IEC 60502-1)

Thickness

Sheath

Conductor Nominal Nominal

Page - 68

Page 71: LV2009

Section 3 - XLPE Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Inner covering : PVC Compound Armour : Galvanized Steel Wire Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Red,Yellow, Blue

Sheath - Black

THREE CORES

1.5 1 / 1.38 1.38 0.7 1.0 0.8 1.8 14.0 343 12.1

1.5 7 / 0.52 1.56 0.7 1.0 0.8 1.8 14.5 360 12.1

2.5 1 / 1.78 1.78 0.7 1.0 0.8 1.8 15.0 398 7.41

2.5 7 / 0.67 2.01 0.7 1.0 0.8 1.8 15.5 417 7.41

4 1 / 2.26 2.26 0.7 1.0 0.8 1.8 16.0 474 4.61

4 7 / 0.85 2.55 0.7 1.0 0.8 1.8 17.0 502 4.61

6 1 / 2.77 2.77 0.7 1.0 0.8 1.8 17.0 570 3.08

6 7 / 1.04 3.12 0.7 1.0 0.8 1.8 18.0 591 3.08

10 7 / 1.35 4.05 0.7 1.0 1.25 1.8 20.5 887 1.83

16 4.7 0.7 1.0 1.25 1.8 22.0 1087 1.15

25 5.9 0.9 1.0 1.6 1.8 26.5 1622 0.727

35 7.1 0.9 1.0 1.6 1.8 29.0 2015 0.524

50 8.1 1.0 1.0 1.6 1.9 31.5 2461 0.387

70 9.7 1.1 1.2 2.0 2.0 37.0 3522 0.268

95 11.6 1.1 1.2 2.0 2.2 41.5 4491 0.193

120 12.9 1.2 1.2 2.0 2.3 45.0 5381 0.153

150 14.3 1.4 1.4 2.5 2.5 50.0 6919 0.124

185 16.0 1.6 1.4 2.5 2.6 55.0 8285 0.0991

240 18.3 1.7 1.6 2.5 2.8 61.5 10398 0.0754

300 20.7 1.8 1.6 2.5 3.0 67.5 12550 0.0601

/km

Compact

round

stranded

mm mm

(approx.)

mm² No./mm mm mm mm mm kg/km

area (approx.) (approx.) (approx.)

Sheath cablecovering of

(approx.) Steel wire

cable at 20°C

Conductor Nominal Nominal Overall Maximum

Thickness diameter Weight ConductorNominal No./ Diameter Thickness Thickness Nominal

of ResistanceCross- Diameter of of of Inner diameter

section of wire Conductor Insulation

of of

600/1000 V XLPE INSULATED, STEEL WIRE ARMOURED AND PVC SHEATHED CABLESXLPE/SWA/PVC (IEC 60502-1)

Page - 69

Page 72: LV2009

Section 3 - XLPE Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Inner covering : PVC Compound Armour : Galvanized Steel Wire Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Red,Yellow, Blue, Black

Sheath - Black

FOUR CORES

1.5 1 / 1.38 1.38 0.7 1.0 0.8 1.8 15.0 384 12.1

1.5 7 / 0.52 1.56 0.7 1.0 0.8 1.8 15.5 398 12.1

2.5 1 / 1.78 1.78 0.7 1.0 0.8 1.8 16.0 455 7.41

2.5 7 / 0.67 2.01 0.7 1.0 0.8 1.8 16.5 471 7.41

4 1 / 2.26 2.26 0.7 1.0 0.8 1.8 17.0 550 4.61

4 7 / 0.85 2.55 0.7 1.0 0.8 1.8 18.0 575 4.61

6 7 / 2.77 2.77 0.7 1.0 1.25 1.8 19.0 755 3.08

6 7 / 1.04 3.12 0.7 1.0 1.25 1.8 19.5 792 3.08

10 7 / 1.35 4.05 0.7 1.0 1.25 1.8 22.0 1039 1.83

16 4.7 0.7 1.0 1.25 1.8 23.5 1292 1.15

25 5.9 0.9 1.0 1.6 1.8 28.5 1955 0.727

35 7.1 0.9 1.0 1.6 1.9 31.5 2440 0.524

50 8.1 1.0 1.0 1.6 2.0 34.5 3039 0.387

70 9.7 1.1 1.2 2.0 2.2 40.5 4345 0.268

95 11.6 1.1 1.2 2.0 2.3 45.0 5577 0.193

120 12.9 1.2 1.4 2.5 2.5 50.0 7191 0.153

150 14.3 1.4 1.4 2.5 2.6 55.0 8600 0.124

185 16.0 1.6 1.4 2.5 2.8 60.5 10388 0.0991

240 18.3 1.7 1.6 2.5 3.0 67.5 13059 0.0754

300 20.7 1.8 1.6 2.5 3.2 74.0 15807 0.0601

600/1000 V XLPE INSULATED, STEEL WIRE ARMOURED AND PVC SHEATHED CABLESXLPE/SWA/PVC (IEC 60502-1)

Conductor Nominal Nominal Overall Maximum

Thickness diameter Weight ConductorNominal No./ Diameter Thickness Thickness Nominal

of of of ResistanceCross- Diameter of of of Inner diameter

section of wire Conductor Insulation covering of Sheath cable

(approx.) Steel wire

cable at 20°C

mm kg/km

area (approx.) (approx.) (approx.)

round

stranded

mm mm

(approx.)

mm² No./mm mm mm mm

Page - 70

/km

Compact

Page 73: LV2009

Section 3 - XLPE Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Inner covering : PVC Compound Armour : Galvanized Steel Wire Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Black with numbering code

Sheath - Black

FIVE CORES

1.5 1 / 1.38 1.38 0.7 1.0 0.8 1.8 16.0 427 12.1

1.5 7 / 0.52 1.56 0.7 1.0 0.8 1.8 16.5 447 12.1

2.5 1 / 1.78 1.78 0.7 1.0 0.8 1.8 17.0 510 7.41

2.5 7 / 0.67 2.01 0.7 1.0 0.8 1.8 17.5 531 7.41

4 1 / 2.26 2.26 0.7 1.0 1.25 1.8 19.0 727 4.61

4 7 / 0.85 2.55 0.7 1.0 1.25 1.8 19.5 763 4.61

6 1 / 2.77 2.77 0.7 1.0 1.25 1.8 20.5 905 3.08

6 7 / 1.04 3.12 0.7 1.0 1.25 1.8 21.0 908 3.08

10 7 / 1.35 4.05 0.7 1.0 1.25 1.8 24.0 1203 1.83

16 4.7 0.7 1.0 1.6 1.8 26.5 1666 1.15

25 5.9 0.9 1.0 1.6 1.8 30.5 2290 0.727

35 7.1 0.9 1.0 1.6 1.9 34.0 2878 0.524

50 8.1 1.0 1.2 2.0 2.1 39.0 3920 0.387

/km

stranded

mm mm mm mm

Compact

(approx.)

mm² No./mm mm mm

round

kg/km

Sheath cable cable at 20°C

area (approx.) (approx.) (approx.) Steel wire (approx.)

of of of Resistance

section of wire Conductor Insulation covering of

Thickness diameter Weight Conductor

Cross- Diameter of of of Inner diameter

Nominal No./ Diameter Thickness Thickness Nominal

600/1000 V XLPE INSULATED, STEEL WIRE ARMOURED AND PVC SHEATHED CABLESXLPE/SWA/PVC (IEC 60502-1)

Conductor Nominal Nominal Overall Maximum

Page - 71

Page 74: LV2009

Section 3 - XLPE Insulated Cables Armoured Cables

Conductor (Annealed Copper) Insulation (XLPE Compound) Filler (Polyprophylene yarn,or extruded filler up to request) Binding tape (Manufacturer's option) Inner Covering (PVC Compound) Galvanized Flat Steel Wire armour Galvanized Steel Tape binding Outer sheath (PVC Compound)

Page - 72

600/1000 V XLPE INSULATED, FLAT STEEL WIRE ARMOURED AND PVC SHEATHED CABLESXLPE/FSWA/PVC (acc. to IEC 60502-1)

1

2

3

4

5

6

7

8

123

45678

Note : Special application upon request* Available product in accordance to : SPLN, ICEA/NEMA,

AS standard or other requirement.* Flame retardant test acc to IEC 60332-3 Cat. A, B or C.* Anti termite performance.* Tin coated Copper conductor.* Polyethylene / Low smoke Halogen Free sheathed

Page 75: LV2009

Section 3 - XLPE Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Inner covering : PVC Compound Armour : Galvanized Flat Steel Wire+Steel tape open helix Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Red,Black

Sheath - Black

TWO CORES

1.5 1 / 1.38 1.38 0.7 1.0 0.8 0.3 1.8 14.0 365 12.1

1.5 7 / 0.52 1.56 0.7 1.0 0.8 0.3 1.8 14.0 398 12.1

2.5 1 / 1.78 1.78 0.7 1.0 0.8 0.3 1.8 14.5 426 7.41

2.5 7 / 0.67 2.01 0.7 1.0 0.8 0.3 1.8 15.0 434 7.41

4 1 / 2.26 2.26 0.7 1.0 0.8 0.3 1.8 15.5 502 4.61

4 7 / 0.85 2.55 0.7 1.0 0.8 0.3 1.8 16.0 514 4.61

6 1 / 2.77 2.77 0.7 1.0 0.8 0.3 1.8 16.5 575 3.08

6 7 / 1.04 3.12 0.7 1.0 0.8 0.3 1.8 17.0 598 3.08

10 7 / 1.35 4.05 0.7 1.0 0.8 0.3 1.8 19.0 744 1.83

16 4.7 0.7 1.0 0.8 0.3 1.8 20.5 896 1.15

25 5.9 0.9 1.0 0.8 0.3 1.8 23.5 1187 0.727

35 7.1 0.9 1.0 0.8 0.3 1.8 26.0 1472 0.524

50 8.1 1.0 1.0 0.8 0.3 1.8 28.5 1804 0.387

70 9.7 1.1 1.0 0.8 0.3 1.9 32.0 2328 0.268

95 11.6 1.1 1.2 0.8 0.3 2.0 36.5 3031 0.193

120 12.9 1.2 1.2 0.8 0.3 2.1 39.5 3635 0.153

150 14.3 1.4 1.2 0.8 0.3 2.2 43.5 4381 0.124

185 16.0 1.6 1.4 0.8 0.3 2.4 48.5 5342 0.0991

240 18.3 1.7 1.4 0.8 0.3 2.6 54.0 6724 0.0754

300 20.7 1.8 1.6 0.8 0.3 2.7 60.0 8222 0.0601

400 23.4 2.0 1.6 0.8 0.3 3.0 66.5 10210 0.0470

Page - 73

Compact

round

stranded

Minimum

thickness

of Galv.

Steel tape

mm

Steel wire

Thickness

of Inner

covering

(approx.)

mm mm mm kg/kmmmmmmm² No./mm mm

area (approx.) (approx.)

section of wire Conductor

ofCross- Diameter of

Overall Maximum

(approx.)

Conductor

at 20°C

(approx.)

of of

/km

Resistance

Weightdiameter

cable cable

Nominal

Nominal No./ Thickness

Sheath

Thickness

Insulation

of

thickness

of Galv.

Flat

Diameter

Nominal

600/1000 V XLPE INSULATED, FLAT STEEL WIRE ARMOURED AND PVC SHEATHED CABLESXLPE/FSWA/PVC (IEC 60502-1)

Conductor Nominal

Page 76: LV2009

Section 3 - XLPE Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Inner covering : PVC Compound Armour : Galvanized Flat Steel Wire+Steel tape open helix Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Red,Yellow, Blue

Sheath - Black

THREE CORES

1.5 1 / 1.38 1.38 0.7 1.0 0.8 0.3 1.8 14.5 418 12.1

1.5 7 / 0.52 1.56 0.7 1.0 0.8 0.3 1.8 14.5 426 12.1

2.5 1 / 1.78 1.78 0.7 1.0 0.8 0.3 1.8 15.0 460 7.41

2.5 7 / 0.67 2.01 0.7 1.0 0.8 0.3 1.8 15.5 497 7.41

4 1 / 2.26 2.26 0.7 1.0 0.8 0.3 1.8 16.0 551 4.61

4 7 / 0.85 2.55 0.7 1.0 0.8 0.3 1.8 17.0 593 4.61

6 1 / 2.77 2.77 0.7 1.0 0.8 0.3 1.8 17.5 665 3.08

6 7 / 1.04 3.12 0.7 1.0 0.8 0.3 1.8 18.0 671 3.08

10 7 / 1.35 4.05 0.7 1.0 0.8 0.3 1.8 20.0 884 1.83

16 4.7 0.7 1.0 0.8 0.3 1.8 21.5 1087 1.15

25 5.9 0.9 1.0 0.8 0.3 1.8 25.0 1466 0.727

35 7.1 0.9 1.0 0.8 0.3 1.8 27.5 1841 0.524

50 8.1 1.0 1.0 0.8 0.3 1.8 30.0 2285 0.387

70 9.7 1.1 1.2 0.8 0.3 2.0 34.5 3070 0.268

95 11.6 1.1 1.2 0.8 0.3 2.1 39.0 3989 0.193

120 12.9 1.2 1.2 0.8 0.3 2.2 42.0 4816 0.153

150 14.3 1.4 1.4 0.8 0.3 2.3 46.5 5871 0.124

185 16.0 1.6 1.4 0.8 0.3 2.4 52.0 7162 0.0991

240 18.3 1.7 1.6 0.8 0.3 2.7 58.0 9123 0.0754

300 20.7 1.8 1.6 0.8 0.3 2.8 64.0 11130 0.0601

Page - 74

Compact

600/1000 V XLPE INSULATED, FLAT STEEL WIRE ARMOURED AND PVC SHEATHED CABLESXLPE/FSWA/PVC (IEC 60502-1)

/kmmm

(approx.)

mm²

Minimum

thickness

of Galv.

round

stranded

mm mmNo./mm mm mm kg/km

area (approx.) (approx.) (approx.)(approx.) Steel wire Steel tape

Sheath cablecovering Flat

mm mm

cable at 20°C

Conductor Nominal Nominal Overall

Thickness thickness

of Inner

Maximum

Cross- Diameter of of

Nominal No./ Diameter Thickness

of of Resistanceof Galv.

diameter Weight Conductor

section of wire Conductor Insulation

of

Thickness

Nominal

Page 77: LV2009

Section 3 - XLPE Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Inner covering : PVC Compound Armour : Galvanized Flat Steel Wire+Steel tape open helix Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Red,Yellow, Blue, Black

Sheath - Black

FOUR CORES

1.5 1 / 1.38 1.38 0.7 1.0 0.8 0.3 1.8 15.0 446 12.1

1.5 7 / 0.52 1.56 0.7 1.0 0.8 0.3 1.8 15.5 483 12.1

2.5 1 / 1.78 1.78 0.7 1.0 0.8 0.3 1.8 16.0 532 7.41

2.5 7 / 0.67 2.01 0.7 1.0 0.8 0.3 1.8 16.5 544 7.41

4 1 / 2.26 2.26 0.7 1.0 0.8 0.3 1.8 17.0 637 4.61

4 7 / 0.85 2.55 0.7 1.0 0.8 0.3 1.8 18.0 659 4.61

6 1 / 2.77 2.77 0.7 1.0 0.8 0.3 1.8 18.5 645 3.08

6 7 / 1.04 3.12 0.7 1.0 0.8 0.3 1.8 19.0 783 3.08

10 7 / 1.35 4.05 0.7 1.0 0.8 0.3 1.8 21.5 1039 1.83

16 4.7 0.7 1.0 0.8 0.3 1.8 23.0 1295 1.15

25 5.9 0.9 1.0 0.8 0.3 1.8 27.0 1795 0.727

35 7.1 0.9 1.0 0.8 0.3 1.8 30.0 2263 0.524

50 8.1 1.0 1.0 0.8 0.3 1.9 32.5 2830 0.387

70 9.7 1.1 1.2 0.8 0.3 2.1 38.0 3838 0.268

95 11.6 1.1 1.2 0.8 0.3 2.2 42.5 5013 0.193

120 12.9 1.2 1.4 0.8 0.3 2.3 47.0 6144 0.153

150 14.3 1.4 1.4 0.8 0.3 2.5 51.5 7450 0.124

185 16.0 1.6 1.4 0.8 0.3 2.7 57.5 9123 0.0991

240 18.3 1.7 1.6 0.8 0.3 2.9 64.0 11666 0.0754

300 20.7 1.8 1.6 0.8 0.3 3.1 70.5 14268 0.0601

Page - 75

600/1000 V XLPE INSULATED, FLAT STEEL WIRE ARMOURED AND PVC SHEATHED CABLESXLPE/FSWA/PVC (IEC 60502-1)

Minimum

thickness

of Galv.

Steel tape

Maximum

Nominal

Conductor Nominal

Thickness thickness

Nominal Overall

Weight Conductor

Cross- Diameter of of

No./ Diameter Thickness Thickness

of wire Conductor Insulation covering

of Inner of Galv.

mm² No./mm

cable

area (approx.) (approx.) (approx.) (approx.)

mm

section

stranded

mm mmmm mm

Compact

Nominal

mm

at 20°CFlat Sheath cable

of of of

diameter

mm /kmkg/km

Resistance

(approx.) Steel wire

round

Page 78: LV2009

Section 3 - XLPE Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 1 or 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Inner covering : XLPE Compound Armour : Galvanized Flat Steel Wire+Steel tape open helix Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Black with numbering code

Sheath - Black

FIVE CORES

1.5 1 / 1.38 1.38 0.7 1.0 0.8 0.3 1.8 16.0 508 12.1

1.5 7 / 0.52 1.56 0.7 1.0 0.8 0.3 1.8 16.5 520 12.1

2.5 1 / 1.78 1.78 0.7 1.0 0.8 0.3 1.8 17.0 601 7.41

2.5 7 / 0.67 2.01 0.7 1.0 0.8 0.3 1.8 17.5 615 7.41

4 1 / 2.26 2.26 0.7 1.0 0.8 0.3 1.8 18.5 730 4.61

4 7 / 0.85 2.55 0.7 1.0 0.8 0.3 1.8 19.0 750 4.61

6 1 / 2.77 2.77 0.7 1.0 0.8 0.3 1.8 20.0 875 3.08

6 7 / 1.04 3.12 0.7 1.0 0.8 0.3 1.8 20.5 897 3.08

10 7 / 1.35 4.05 0.7 1.0 0.8 0.3 1.8 23.0 1196 1.83

16 4.7 0.7 1.0 0.8 0.3 1.8 25.0 1512 1.15

25 5.9 0.9 1.0 0.8 0.3 1.8 29.0 2100 0.727

35 7.1 0.9 1.0 0.8 0.3 1.9 32.5 2700 0.524

50 8.1 1.0 1.2 0.8 0.3 2.0 36.0 3432 0.387

Page - 76

round

stranded

Compact

600/1000 V XLPE INSULATED, FLAT STEEL WIRE ARMOURED AND PVC SHEATHED CABLESXLPE/FSWA/PVC (IEC 60502-1)

NominalConductor Nominal Nominal Overall Maximum

Steel tape

mm

thickness

kg/km /km

(approx.)

of Galv.

mm² No./mm mm mm mm mm mm mm

Sheath cable cable at 20°C

area (approx.) (approx.) (approx.) Steel wire (approx.)

of of of Resistance

section of wire Conductor Insulation covering Flat

Thickness thickness Weight Conductor

Cross- Diameter of of of Inner of Galv.

Thickness diameterMinimumNominal No./ Diameter Thickness

Page 79: LV2009

Section 3 - XLPE Insulated Cables

600/1000 V XLPE INSULATED, ALUMINIUM TAPE ARMOURED AND PVC SHEATHED CABLES

Constructions :

Conductor (Annealed Copper)

Insulation (XLPE Compound)

Inner Covering (PVC Compound)

Outer sheath (PVC Compound)

600/1000 V XLPE INSULATED, STEEL TAPE ARMOURED AND PVC SHEATHED CABLES

Constructions :

Conductor (Annealed Copper)

Insulation (XLPE Compound)

up to request)

Binding tape (Manufacturer's option)

Inner Covering (PVC Compound)

Outer sheath (PVC Compound)

Page - 77

Armoured Cables

XLPE/DATA/PVC (acc. to IEC 60502-1)

Double Aluminium Tape armour

XLPE/DSTA/PVC (acc. to IEC 60502-1)

Filler (Polyprophylene yarn,or extruded filler

Double Galvanized Steel Tape armour

11

2

3

5

4

6

7

2

3

4

5

6

7

1

2

3

4

5

1

2

3

4

5

Note : Special application upon request* Available product in accordance to : SPLN, ICEA/NEMA,

AS standard or other requirement.* Flame retardant test acc to IEC 60332-3 Cat. A, B or C.* Anti termite performance.* Tin coated Copper conductor.* Polyethylene / Low smoke Halogen Free sheathed

Page 80: LV2009

Section 3 - XLPE Insulated Cables

600/1000 V XLPE INSULATED, ALUMINIUM TAPE ARMOURED AND PVC SHEATHED CABLES

XLPE/DATA/PVC (IEC 60502-1)

CONSTRUCTION TECHNICAL DATA

Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2)

Insulation : XLPE Compound Operating Temperature

Inner covering : PVC Compound Maximum 90°C

Armour

Sheath : PVC Compound type ST2

: Insulation - Black

Sheath - Black

SINGLE CORE

Conductor Nominal Nominal Nominal Overall Maximum

Nominal No./ Diameter Thickness Thickness Thickness Thickness diameter Weight Conductor

Cross- Diameter of of of Inner of of of of Resistance

section of wire Conductor Insulation covering Sheath cable cable at 20°C

area (approx.) (approx.) (approx.) tape (approx.) (approx.)

mm² No./mm mm mm mm mm mm mm kg/km

16 4.7 0.7 1.0 0.5 1.8 13.5 335 1.15

25 5.9 0.9 1.0 0.5 1.8 15.0 455 0.73

35 7.1 0.9 1.0 0.5 1.8 16.5 570 0.52

50 Compact 8.1 1.0 1.0 0.5 1.8 17.5 705 0.39

70 round 9.7 1.1 1.0 0.5 1.8 19.5 930 0.27

95 stranded 11.6 1.1 1.0 0.5 1.8 21.5 1210 0.19

120 12.9 1.2 1.0 0.5 1.8 23.0 1470 0.15

150 14.3 1.4 1.0 0.5 1.8 24.5 1760 0.12

185 16.0 1.6 1.0 0.5 1.8 27.0 2155 0.1

240 18.3 1.7 1.0 0.5 1.8 29.5 2735 0.08

300 20.7 1.8 1.0 0.5 1.9 32.0 3365 0.06

400 23.4 2.0 1.2 0.5 2.0 35.5 4240 0.0470

500 26.5 2.2 1.2 0.5 2.1 39.5 5350 0.04

630 30.3 2.4 1.2 0.5 2.3 44.0 6670 0.03

Page - 78

Armoured Cables

Uo/U - 600/1000 V

: Double Aluminium tape

Colour Ident.

Aluminium

W/km

Page 81: LV2009

Section 3 - XLPE Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Inner covering : PVC Compound Armour : Double Galvanized Steel tape Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Red,Black

Sheath - Black

TWO CORES

1.5 1 / 1.38 1.38 0.7 1.0 0.2 1.8 12.5 220

1.5 7 / 0.52 1.56 0.7 1.0 0.2 1.8 13.0 230 12.1

2.5 1 / 1.78 1.78 0.7 1.0 0.2 1.8 13.0 258 7.41

2.5 7 / 0.67 2.01 0.7 1.0 0.2 1.8 13.5 268 7.41

4 1 / 2.26 2.26 0.7 1.0 0.2 1.8 14.0 312 4.61

4 7 / 0.85 2.55 0.7 1.0 0.2 1.8 15.0 326 4.61

6 1 / 2.77 2.77 0.7 1.0 0.2 1.8 15.0 372 3.08

6 7 / 1.04 3.12 0.7 1.0 0.2 1.8 16.0 387 3.08

10 7 / 1.35 4.05 0.7 1.0 0.2 1.8 18.0 514 1.83

16 4.7 0.7 1.0 0.2 1.8 19.0 643 1.15

25 5.9 0.9 1.0 0.2 1.8 23.0 893 0.727

35 7.1 0.9 1.0 0.2 1.8 24.5 1134 0.524

50 8.1 1.0 1.0 0.2 1.8 27.0 1422 0.387

70 9.7 1.1 1.0 0.2 1.9 30.5 1905 0.268

95 11.6 1.1 1.2 0.2 2.0 35.0 2544 0.193

120 12.9 1.2 1.2 0.5 2.1 39.5 3505 0.153

150 14.3 1.4 1.4 0.5 2.3 43.5 4245 0.124

185 15.9 1.6 1.4 0.5 2.4 48.5 5180 0.0991

240 18.3 1.7 1.6 0.5 2.6 54.0 6530 0.0754

300 20.7 1.8 1.6 0.5 2.7 59.5 8004 0.0601

Conductor Nominal Nominal

600/1000 V XLPE INSULATED, STEEL TAPE ARMOURED AND PVC SHEATHED CABLESXLPE/DSTA/PVC (IEC 60502-1)

Thickness

Sheath

Weightdiameter

cable cable at 20°C

(approx.)

/km

Resistance

Overall Maximum

(approx.)

Nominal No./ Diameter Thickness

Insulation

Conductor

Cross- Diameter of of of of of

section of wire Conductor

mm² No./mm mm

area (approx.) (approx.)

mm mm mm kg/kmmmmm

Compact

round

stranded

Nominal

thickness

of

Steel tape

Thickness

of Inner

covering

(approx.)

Page - 79

Page 82: LV2009

Section 3 - XLPE Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Inner covering : PVC Compound Armour : Double Galvanized Steel tape Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Red,Yellow, Blue

Sheath - Black

THREE CORES

1.5 1 / 1.58 1.58 0.7 1.0 0.2 1.8 13.0 249

1.5 7 / 0.52 1.56 0.7 1.0 0.2 1.8 13.5 259 12.1

2.5 1 / 1.78 1.78 0.7 1.0 0.2 1.8 13.5 294 7.41

2.5 7 / 0.67 2.01 0.7 1.0 0.2 1.8 14.0 307 7.41

4 1 / 2.26 2.26 0.7 1.0 0.2 1.8 15.0 263 4.61

4 7 / 0.85 2.55 0.7 1.0 0.2 1.8 15.5 381 4.61

6 1 / 2.77 2.77 0.7 1.0 0.2 1.8 16.0 445 3.08

6 7 / 1.04 3.12 0.7 1.0 0.2 1.8 16.5 463 3.08

10 7 / 1.35 4.05 0.7 1.0 0.2 1.8 18.5 630 1.83

16 4.7 0.7 1.0 0.2 1.8 20.0 812 1.15

25 5.9 0.9 1.0 0.2 1.8 23.5 1150 0.727

35 7.1 0.9 1.0 0.2 1.8 26.0 1481 0.524

50 8.1 1.0 1.0 0.2 1.8 28.5 1882 0.387

70 9.7 1.1 1.2 0.2 1.9 33.0 2588 0.268

95 11.6 1.1 1.2 0.2 2.1 37.5 3456 0.193

120 12.9 1.2 1.2 0.5 2.2 42.0 4669 0.153

150 14.3 1.4 1.4 0.5 2.4 46.5 5708 0.124

185 15.9 1.6 1.4 0.5 2.5 51.5 6965 0.0991

240 18.3 1.7 1.6 0.5 2.7 58.0 8905 0.0754

300 20.7 1.8 1.6 0.5 2.9 64.0 10919 0.0601

section of wire Conductor Insulation

600/1000 V XLPE INSULATED, STEEL TAPE ARMOURED AND PVC SHEATHED CABLESXLPE/DSTA/PVC (IEC 60502-1)

Weight Conductor

Cross- Diameter of of of of of Resistance

Nominal No./ Diameter Thickness Thickness diameter

Maximum

cable at 20°C

Conductor Nominal Nominal Overall

(approx.) (approx.)

Sheath cablecovering of

(approx.) Steel tape (approx.)

mm² No./mm mm mm mm mm kg/km

area (approx.)

/km

Compact

round

stranded

mm mm

of Inner thickness

Page - 80

Thickness Nominal

Page 83: LV2009

Section 3 - XLPE Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Inner covering : PVC Compound Armour : Double Galvanized Steel tape Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Red,Yellow, Blue, Black

Sheath - Black

FOUR CORES

1.5 1 / 1.38 1.38 0.7 1.0 0.2 1.8 13.5 280

1.5 7 / 0.52 1.56 0.7 1.0 0.2 1.8 14.0 293 12.1

2.5 1 / 1.78 1.78 0.7 1.0 0.2 1.8 14.5 343 7.41

2.5 7 / 0.67 2.01 0.7 1.0 0.2 1.8 15.0 357 7.41

4 1 / 2.26 2.26 0.7 1.0 0.2 1.8 16.0 426 4.61

4 7 / 0.85 2.55 0.7 1.0 0.2 1.8 16.5 446 4.61

6 1 / 2.77 2.77 0.7 1.0 0.2 1.8 17.0 531 3.08

6 7 / 1.04 3.12 0.7 1.0 0.2 1.8 17.5 552 3.08

10 7 / 1.35 4.05 0.7 1.0 0.2 1.8 20.0 764 1.83

16 4.7 0.7 1.0 0.2 1.8 21.5 999 1.15

25 5.9 0.9 1.0 0.2 1.8 25.5 1434 0.727

35 7.1 0.9 1.0 0.2 1.8 28.5 1859 0.524

50 8.1 1.0 1.0 0.2 1.9 31.5 2383 0.387

70 9.7 1.1 1.2 0.2 2.0 36.0 3311 0.268

95 11.6 1.1 1.2 0.5 2.2 42.5 4872 0.193

120 12.9 1.2 1.4 0.5 2.4 46.5 5983 0.153

150 14.3 1.4 1.4 0.5 2.5 51.0 7274 0.124

185 15.9 1.6 1.4 0.5 2.7 57.0 8922 0.0991

240 18.3 1.7 1.6 0.5 2.9 64.0 11427 0.0754

300 20.7 1.8 1.6 0.5 3.1 70.5 14015 0.0601

/km

Compact

round

stranded

mm mm

(approx.)

mm² No./mm mm mm mm mm kg/km

area (approx.) (approx.) (approx.)

Sheath cable

(approx.) Steel tape

cable at 20°Csection of wire Conductor Insulation covering of

Weight Conductor

Cross- Diameter of of of of of Resistance

Nominal No./ Diameter Thickness Thickness diameter

Conductor Nominal Nominal Overall Maximum

600/1000 V XLPE INSULATED, STEEL TAPE ARMOURED AND PVC SHEATHED CABLESXLPE/DSTA/PVC (IEC 60502-1)

Page - 81

Thickness Nominal

of Inner thickness

Page 84: LV2009

Section 3 - XLPE Insulated Cables Armoured Cables

CONSTRUCTION TECHNICAL DATA Conductor : Plain Annealed Copper Voltage

(to IEC 60228 class 2) Uo/U - 600/1000 V Insulation : XLPE Compound Operating Temperature Filler : Suitable material Maximum 90°C Inner covering : PVC Compound Armour : Double Galvanized Steel tape Sheath : PVC Compound type ST2 Colour Ident. : Insulation - Black with numbering code

Sheath - Black

FIVE CORES

1.5 1 / 1.38 1.38 0.7 1.0 0.2 1.8 14.5 319

1.5 7 / 0.52 1.56 0.7 1.0 0.2 1.8 15.0 333 12.1

2.5 1 / 1.78 1.78 0.7 1.0 0.2 1.8 15.5 390 7.41

2.5 7 / 0.67 2.01 0.7 1.0 0.2 1.8 16.0 405 7.41

4 1 / 2.26 2.26 0.7 1.0 0.2 1.8 17.0 496 4.61

4 7 / 0.85 2.55 0.7 1.0 0.2 1.8 17.5 520 4.61

6 1 / 2.77 2.77 0.7 1.0 0.2 1.8 18.5 620 3.08

6 7 / 1.04 3.12 0.7 1.0 0.2 1.8 19.0 645 3.08

10 7 / 1.35 4.05 0.7 1.0 0.2 1.8 22.0 900 1.83

16 4.7 0.7 1.0 0.2 1.8 23.5 1196 1.15

25 5.9 0.9 1.0 0.2 1.8 27.5 1720 0.727

35 7.1 0.9 1.0 0.2 1.9 31.0 2252 0.524

50 8.1 1.0 1.2 0.2 2.0 35.0 2946 0.387

stranded

kg/km /km

round

mm mm

(approx.)

mm mm

Compact

mm² No./mm mm mm

Sheath cable cable at 20°C

area (approx.) (approx.) (approx.) Steel tape (approx.)

of of of Resistance

section of wire Conductor Insulation covering of

Thickness diameter Weight Conductor

Cross- Diameter of of of Inner thickness

Nominal No./ Diameter Thickness Thickness Nominal

600/1000 V XLPE INSULATED, STEEL TAPE ARMOURED AND PVC SHEATHED CABLESXLPE/DSTA/PVC (IEC 60502-1)

Conductor Nominal Nominal Overall Maximum

Page - 82

Page 85: LV2009

CURRENT CARRYING CAPACITY FOR SINGLE CORE XLPE INSULATED CABLE

Current Carrying Capacity DC Alternating Minimum Conductor

Conductor In Air ( 30°C ) Conductor Current Insulation Short

Nominal Flat Trefoil Trefoil Resistance resistance Nominal Resistance circuit

Area at 20°C at 90°C / Trefoil Flat Trefoil Flat Capacitance at 20°C current /

50 Hzcore to core core to core 1 sec

mm² A A A Ω / km Ω / km Ω / km Ω / km M Ω. km

1.5 re/rm 22 21 22 12.1 15.4 0.1459 0.1603 0.4646 0.5108 0.0520 3000 0.215

2.5 re/rm 30 29 29 7.41 9.45 0.1339 0.1484 0.4264 0.4726 0.0571 2500 0.358

4 re/rm 42 40 37 4.61 5.88 0.1244 0.1391 0.3962 0.4424 0.0621 2000 0.572

6 re/rm 55 53 46 3.08 3.93 0.1160 0.1305 0.3693 0.4155 0.0665 2000 0.858

10 re/rm 77 74 61 1.83 2.34 0.1072 0.1217 0.3416 0.3878 0.0721 1500 1.430

16 cm 105 101 79 1.15 1.47 0.1028 0.1172 0.3264 0.3726 0.0751 1500 2.288

25 cm 141 135 101 0.73 0.93 0.0984 0.1130 0.3124 0.3586 0.0752 1500 3.575

35 cm 176 169 122 0.52 0.67 0.0932 0.1077 0.2967 0.3429 0.0789 1000 5.005

50 cm 216 207 144 0.39 0.49 0.0911 0.1056 0.2890 0.3353 0.0796 1000 7.150

70 cm 279 268 178 0.27 0.34 0.0875 0.1023 0.2778 0.3240 0.0815 900 10.01

95 cm 342 328 211 0.19 0.25 0.0845 0.0991 0.2674 0.3136 0.0848 800 13.59

120 cm 400 383 240 0.15 0.2 0.0827 0.0974 0.2629 0.3091 0.0853 800 17.16

150 cm 464 444 271 0.12 0.16 0.0829 0.0975 0.2626 0.3088 0.0846 800 21.45

185 cm 533 510 304 0.1 0.127 0.0830 0.0976 0.2612 0.3074 0.0833 900 26.46

240 cm 634 607 351 0.08 0.1 0.0814 0.0960 0.2565 0.3028 0.0848 800 34.32

300 cm 736 703 396 0.06 0.08 0.0799 0.0944 0.2526 0.2988 0.0860 800 42.90

400 cm 868 823 464 0.0470 0.06 0.0728 0.0874 0.2500 0.2962 0.0865 700 57.20

500 cm 998 946 525 0.04 0.05 0.0777 0.0923 0.2471 0.2933 0.0871 700 71.50

630 cm 1151 1088 596 0.03 0.04 0.0770 0.0916 0.2447 0.2909 0.0880 700 90.09

800 cm 1328 1252 679 0.02 0.0310 0.0763 0.0908 0.2425 0.2887 0.0883 700 114.40

1000 rm 1511 1420 767 0.02 0.03 0.0743 0.0889 0.2363 0.2825 0.0902 600 143.00

Note : re : Round solid conductor IEC 60228 class 1 Underground : Thermal resistivity of soil

rm : Circular stranded conductor IEC 60228 class 2 Depth of laying : 80 cm capacity for : in cable ducting, in cables conduit, cables direct in the -

cm : Circular stranded compacted conductor IEC 60228 class 2 Base temperature : 20°C ground with / without added protection against mechanical damage

Reactance2) (50 Hz) Inductance2) (50 Hz)In Ground 1)

mH / km mH / km μF / km kA

: 2.5 K.m / W Note : 1) Reference methode of installation to be used to obtain current carrying

2) The Inductance calculated for non armour cable.

Section

4-

Gen

eralInformatio

n

Pag

e-

83

Page 86: LV2009

DC Alternating Minimum ConductorConductor Current Insulation Short

Resistance resistance Nominal Resistance circuit 2 3 / 4 * 2 3 / 4 * at 20°C at 90°C / 2 / 3 4 2 / 3 4 Capacitance at 20°C current /

NominalArea

CURRENT CARRYING CAPACITY FOR MULTICORE XLPE INSULATED CABLE

Current Carrying Capacity Reactance (50 Hz) Inductance (50 Hz)

Conductor In Air ( 30°C ) Underground, Direct burial

Section 4 -General Information

Page -84

Core Core Core Core 50 Hz Core Core Core Core core to core core to core 1 sec

A A A A Ω / km Ω / km Ω / km Ω / km mH / km mH / km µF / km M Ω. km kA

1.5 re/rm 26 23 26 22 12.1 15.4 0.0999 0.1125 0.3181 0.2498 0.0520 3000 0.2152.5 re/rm 36 32 34 29 7.41 9.45 0.0961 0.1086 0.3057 0.2325 0.0571 2500 0.3584 re/rm 49 42 44 37 4.61 5.88 0.0899 0.1025 0.2860 0.2128 0.0621 2000 0.5726 re/rm 63 54 56 46 3.08 3.93 0.0853 0.0980 0.2714 0.1982 0.0665 2000 0.858

10 re/rm 86 75 73 61 1.83 2.34 0.0802 0.0930 0.2552 0.1819 0.0721 1500 1.43016 cm 115 100 95 79 1.15 1.47 0.0781 0.0910 0.2485 0.1752 0.0751 1500 2.28825 cm 149 127 121 101 0.727 0.927 0.0779 0.0908 0.2480 0.1748 0.0752 1500 3.57535 cm 185 158 146 122 0.524 0.669 0.0753 0.0883 0.2397 0.1664 0.0789 1000 5.005

50 cm 225 192 173 144 0.387 0.494 0.0748 0.0877 0.2379 0.1646 0.0796 1000 7.15070 cm 289 246 213 178 0.268 0.343 0.0734 0.0864 0.2335 0.1602 0.0815 900 10.0195 cm 352 298 252 211 0.193 0.247 0.0711 0.0842 0.2262 0.1530 0.0848 800 13.59

mm²

120 cm 410 346 287 240 0.153 0.197 0.0708 0.0839 0.2254 0.1521 0.0853 800 17.16

150 cm 473 399 324 271 0.124 0.160 0.0712 0.0843 0.2267 0.1534 0.0846 800 21.45185 cm 542 456 363 304 0.0991 0.128 0.0720 0.0851 0.2292 0.1559 0.0833 900 26.46240 cm 641 538 419 351 0.0754 0.0984 0.0711 0.0842 0.2264 0.1531 0.0848 800 34.32300 cm 741 621 474 396 0.0601 0.0799 0.0704 0.0835 0.2240 0.1507 0.0860 800 42.90400 cm 892 745 555 464 0.0470 0.0633 0.0701 0.0832 0.2231 0.1498 0.0865 700 57.20

Note : re : Round solid conductor IEC 60228 class 1 Thermal resistivity of soil : 2.5 K.m / W 4* : 3 Phasa + Netral / Groundrm : Circular stranded conductor IEC 60228 class 2 Depth of laying : 80 cmcm : Circular stranded compacted conductor IEC 60228 class 2 Base temperature : 20°C

Underground :

Section 4

Page

Page 87: LV2009

CURRENT CARRYING CAPACITY FOR SINGLE CORE PVC INSULATED CABLE

Current Carrying Capacity DC Alternating Minimum Conductor

Conductor In Air ( 30°C ) Conductor Current Insulation Short

Nominal Flat Trefoil Trefoil Resistance resistance Nominal Resistance circuit

Area at 20°C at 70°C / Trefoil Flat Trefoil Flat Capacitance at 20°C current /

50 Hzcore to core core to core 1 sec

mm² A A A Ω / km Ω / km Ω / km Ω / km M Ω. km kA

1.5 re/rm 18 17.5 18.5 12.1 14.5 0.1476 0.1735 0.4697 0.5159 0.1391 50 0.174

2.5 re/rm 25 24 24 7.41 8.87 0.1359 0.1621 0.4327 0.4789 0.1531 50 0.290

4 re/rm 34 33 31 4.61 5.52 0.1291 0.1555 0.4110 0.4572 0.1553 50 0.464

6 re/rm 45 43 39 3.08 3.69 0.1209 0.1475 0.3848 0.4310 0.1671 50 0.696

10 re/rm 63 60 52 1.83 2.19 0.1112 0.1381 0.3538 0.4000 0.1827 50 1.160

16 rm 85 82 67 1.15 1.38 0.1034 0.1307 0.3292 0.3754 0.1966 40 1.856

25 rm 114 110 86 0.73 0.870 0.0988 0.1263 0.3145 0.3607 0.2001 40 2.900

35 rm 143 137 103 0.52 0.627 0.0941 0.1218 0.2995 0.3457 0.2100 40 4.060

50 rm 174 167 122 0.39 0.463 0.0909 0.1188 0.2895 0.3357 0.2127 30 5.800

70 rm 225 216 151 0.27 0.321 0.0869 0.1150 0.2767 0.3229 0.2223 30 8.120

95 rm 275 264 179 0.19 0.232 0.0864 0.1145 0.2749 0.3212 0.2205 30 11.02

120 rm 321 308 203 0.15 0.184 0.0838 0.1121 0.2669 0.3131 0.2270 30 13.92

150 rm 372 356 230 0.12 0.150 0.0833 0.1116 0.2651 0.3113 0.2274 20 17.40

185 rm 427 409 258 0.1 0.120 0.0828 0.1111 0.2634 0.3096 0.2279 20 21.46

240 rm 507 485 297 0.08 0.09 0.0814 0.1098 0.2592 0.3054 0.2308 20 27.84

300 rm 587 561 336 0.06 0.07 0.0807 0.1091 0.2567 0.3029 0.2323 20 34.80

400 rm 689 656 394 0.0470 0.06 0.0799 0.1084 0.2543 0.3005 0.2387 20 46.40

500 rm 789 749 445 0.04 0.05 0.0790 0.1075 0.2513 0.2975 0.2355 20 58.00

630 rm 905 855 506 0.03 0.04 0.0773 0.1059 0.2459 0.2921 0.2416 20 73.08

800 rm 1037 971 577 0.02 0.0334 0.0756 0.1044 0.2406 0.2868 0.2476 20 92.80

1000 rm 1167 1079 652 0.02 0.0290 0.0750 0.1038 0.2386 0.2848 0.2500 20 116.00

Note : re : Round solid conductor IEC 60228 class 1 Underground : Thermal resistivity of soil

rm : Circular stranded conductor IEC 60228 class 2 Depth of laying : 80 cm capacity for : in cable ducting, in cables conduit, cables direct in the -

Base temperature : 20°C ground with / without added protection against mechanical damage

Reactance2) (50 Hz) Inductance 2) (50 Hz)In Ground 1)

mH / km mH / km μF / km

: 2.5 K.m / W Note : 1) Reference methode of installation to be used to obtain current carrying

2) The Inductance calculated for non armour cable.

Sectio

n4

-G

eneralIn

formation

Pag

e-

85

Page 88: LV2009

DC Alternating Minimum ConductorConductor Current Insulation Short

Resistance resistance Nominal Resistance circuit 2 3 / 4 * 2 3 / 4 * at 20°C at 70°C / 2 / 3 4 2 / 3 4 Capacitance at 20°C current /

core to core core to core 1 sec

Reactance (50 Hz) Inductance (50 Hz)In Air ( 30°C ) Underground, Direct burial

CURRENT CARRYING CAPACITY FOR MULTICORE PVC INSULATED CABLE

Current Carrying Capacity

NominalArea

Conductor

Section 4 -General Information

Page -86

Core Core Core Core 50 Hz Core Core Core Core core to core core to core 1 sec

A A A A Ω / km Ω / km Ω / km Ω / km mH / km mH / km µF / km M Ω. km kA

1.5 re/rm 22 18.5 22 18 12.1 14.5 0.1075 0.1199 0.3421 0.2688 0.1391 50 0.1742.5 re/rm 30 25 29 24 7.41 8.87 0.0994 0.1120 0.3165 0.2433 0.1531 50 0.2904 re/rm 40 34 38 31 4.61 5.52 0.0983 0.1109 0.3130 0.2398 0.1553 50 0.4646 re/rm 51 43 47 39 3.08 3.69 0.0928 0.1054 0.2954 0.2221 0.1671 50 0.696

10 re/rm 70 60 63 52 1.83 2.19 0.0865 0.0993 0.2754 0.2021 0.1827 50 1.16016 rm 94 80 81 67 1.15 1.38 0.0818 0.0946 0.2604 0.1871 0.1966 40 1.85625 rm 119 101 104 86 0.727 0.870 0.0807 0.0936 0.2569 0.1836 0.2001 40 2.90035 rm 148 126 125 103 0.524 0.627 0.0778 0.0907 0.2478 0.1745 0.2100 40 4.060

50 rm/sm 180 153 148 122 0.387 0.464 0.0822 0.0950 0.2617 0.1884 0.2127 30 5.80070 rm/sm 232 196 183 151 0.268 0.321 0.0789 0.0917 0.2510 0.1777 0.2223 30 8.12095 rm/sm 282 238 216 179 0.193 0.232 0.0791 0.0920 0.2518 0.1785 0.2205 30 11.020120 rm/sm 328 276 246 203 0.153 0.184 0.0772 0.0901 0.2457 0.1724 0.2270 30 13.920

mm²

120 rm/sm 328 276 246 203 0.153 0.184 0.0772 0.0901 0.2457 0.1724 0.2270 30 13.920

150 rm/sm 379 319 278 230 0.124 0.150 0.0775 0.0904 0.2466 0.1733 0.2274 20 17.400185 rm/sm 434 364 312 258 0.0991 0.120 0.0769 0.0898 0.2447 0.1714 0.2279 20 21.460240 rm/sm 514 430 361 297 0.0754 0.0926 0.0759 0.0889 0.2417 0.1684 0.2308 20 27.840300 rm/sm 593 497 408 336 0.0601 0.0749 0.0756 0.0886 0.2407 0.1674 0.2323 20 34.80

Note : re : Round solid conductor IEC 60228 class 1 Thermal resistivity of soil : 2.5 K.m / W 4* : 3 Phasa + Netral / Groundrm : Circular stranded conductor IEC 60228 class 2 Depth of laying : 80 cmsm : Sector shape stranded conductor IEC 60228 class 2 Base temperature : 20°C

Underground :

Page 89: LV2009

Rating factor relating to open air temperature

Air temperature°C 10 15 20 25 30 35 40 45 50 55 60 65 70 80

PVC Insulation 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50 - - -

XLPE Insulation 1.15 1.12 1.08 1.04 1.00 0.96 0.91 0.87 0.82 0.76 0.71 0.65 0.58 0.41

Rating factor relating to Ground temperature

Ground temp °C 10 15 20 25 30 35 40 45 50 55 60 65 70 80

PVC Insulation 1.10 1.05 1.00 0.95 0.89 0.84 0.77 0.71 0.63 0.55 0.45 - - -

XLPE Insulation 1.07 1.04 1.00 0.96 0.93 0.89 0.85 0.80 0.76 0.71 0.65 0.60 0.53 0.38

1 1.5 2 2.5 3

Rating factors 1.18 1.1 1.05 1.00 0.96

Number of coreRating factor based on 3 core cable for size 1.5 ~ 10 mm²

Under ground In Air

5 0.70 0.75

7 0.60 0.65

10 0.50 0.55

14 0.45 0.50

19 0.40 0.45

24 0.35 0.40

40 0.30 0.35

61 0.25 0.30

Correction factor of Curent carrying capacity

Rating factor relating to themal ground resistivity

Thermal Resistivity of soil K.m / W

Sectio

n4

-G

eneralInfo

rmation

Pag

e-

87

Page 90: LV2009

Section 4 - General Information

to be applied to reference ratings for multi-core cables in free air

Method of installationNumber Number of cables

of trays 1 2 3 4 6 9

1 1.00 0.88 0.82 0.79 0.76 0.73

2 1.00 0.87 0.80 0.77 0.73 0.68

3 1.00 0.86 0.79 0.76 0.71 0.66

Perforated trays

(note 2)

1 1.00 1.00 0.98 0.95 0.91 -

2 1.00 0.99 0.96 0.92 0.87 -

3 1.00 0.98 0.95 0.91 0.85 -

1 1.00 0.88 0.82 0.78 0.73 0.72

2 1.00 0.88 0.81 0.76 0.71 0.70

Vertical

Perforated

trays

(note 3)

1 1.00 0.91 0.89 0.88 0.87 -

2 1.00 0.91 0.88 0.87 0.85 -

1 1.00 0.87 0.82 0.80 0.79 0.78

2 1.00 0.86 0.80 0.78 0.76 0.73

Ladder 3 1.00 0.85 0.79 0.76 0.73 0.70

supports,

cleats, etc.

(note 2) 1 1.00 1.00 1.00 1.00 1.00 -

2 1.00 0.99 0.98 0.97 0.96 -

3 1.00 0.98 0.97 0.96 0.93 -

Factors apply to single layer groups of cables as shown above and do not apply when cables are installed in more than one layer touching each other.

Values for such installations may be significantly lower and shall be determined by an appropriate method.

NOTE 1

NOTE 2 Values are given for vertical a spacing between trays of 300 mm and at least 20 mm between trays and wall. For closer spacing the factors

should be reduced.

NOTE 3 Values are given for horizontal spacing between trays of 225 mm with trays mounted back to back. For closer spacing the factors should be

reduced.

Page - 88

Reduction factors for group of more than one multi-core cable (note 1)

Values given are averages for the cable types and range of conductor sizes considered. The spread of values is generally less than ± 5 %.

Touching

Spaced

≥ 20 mm

≥ 20 mm

Touching

Spaced

Touching

Spaced

≥ 20 mm

≥ 20 mm

≥225 mm

≥225 mm

D

D

D

Page 91: LV2009

Section 4 - General Information

to be applied to reference rating for one circuit of single-core cables in free air

Method of installationNumber of Use as a multiplier to

trays 1 2 3 rating for

Perforated 1 0.98 0.91 0.87 Three cables in

trays 2 0.96 0.87 0.81 horizontal

(Note 3) 3 0.95 0.85 0.78 formation

Vertically

Perforated 1 0.96 0.86 - Three cables

trays

(note 4) 2 0.95 0.84 - formation

Ladder 1 1.00 0.97 0.96 Three cables in

supports,cleats etc. 2 0.98 0.93 0.89 horizontal

(Note 3) 3 0.97 0.90 0.86 formation

Perforated 1 1.00 0.98 0.96

trays 2 0.97 0.93 0.89

(Note 3) 3 0.96 0.92 0.86

Vertical 1 1.00 0.91 0.89 Three cables in

perforated trays trefoil

(Note 4) 2 1.00 0.90 0.86 formation

Ladder 1 1.00 1.00 1.00

supports,cleats etc. 2 0.97 0.95 0.93

(Note 3) 3 0.96 0.94 0.90

NOTE 1

NOTE 2 For circuits having more than one cable in parallel per phase, each three phase set of conductors should be considered as a circuit for the

purpose of this table

NOTE 3

NOTE 4 Values are given for horizontal spacings between trays of 225 mm with trays mounted back to back and at least 20 mm between the tray

and any wall. For closer spacing the factors should be reduced.

Page - 89

Reduction factors for groups of more than one circuit of single-core cables (Note 1)

in vertcal

Value given are averages for the cable types and range of conductor sizes considered. The spread of values is generally less than ± 5 %.

Values are given for vertical spacings between trays of 300 mm.For closer spacing the factors should be reduced.

Touching

≥ 20 mm

Spaced

Touching

≥ 20 mm

≥ 20 mm

≥ 2 D

225 mm

≥ 2 D

≥ 20 mm

≥ 2 D

Touching

≥225 mm

D

D

D

Page 92: LV2009

Section 4 - General Information

PERMISSIBLE PULLING TENSION

Pulling equipment Permissible pulling tension (kg)

PULLING EYE 7 x (Number of core) x (Cross section area of conductor)

CABLE NET About 500 kg, but the maximum tension shall not be more than one of

conductor (same calculation as using PULLING EYE)

Pulling equipment Permissible pulling tension (kg)

PULLING EYE 4 x (Number of core) x (Cross section area of conductor)

CABLE NET About 500 kg, but the maximum tension shall not be more than one of

conductor (same calculation as using PULLING EYE)

Note) Cable net shall be covered more than 500 mm in length

MINIMUM BENDING RADIUS D : Diameter of cable

Type of cable

Minimum bending radius

Single core cableMulti Core Cable

Round / Compacted Conductor Sector conductor

Medium Voltage Cable 10D 12D 8D

Reference data on other types of POWER cables

Type of cable

Minimum bending radius

Single core cable

Multi core cableRound/CompactedSector conductor

conductor

10D 12D 8D

8D 12D 6D

Triplex type cable ( CVT etc ) - - 8D

Wire armored cable ( XLPE/SWA/PVC etc) 10D 12D 10D

Tape armored cable (XLPE/DSTA/PVC etc) 10D 12D 10D

Flat tape armored (XLPE/FSWA/PVC etc) 10D 12D 10D

Reference data on other types of INSTRUMENT cables

Type of cableMinimum bending radius

Multi core cable

Non shield cable ( XLPE/PVC etc ) 6D

6D AL mylar tape

PERMISSIBLE SIDE WALL PRESSURE

Side wall pressure (T1) can be calculated with below formula.

T1 = Pulling tension (T) / Bending radius (r)

CALCULATION OF CABLE PULLING TENSION DURING INSTALLATION

The cable pulling tension (T2) during installation can be calculated with below formula.

1) Horizontal straight part : W : Weight of cable (kg/m)

2) Horizontal curve part : L : Length of cable with straight part (m)

: Angle of curve part (rad)

: Friction factor Friction factor T2 : Pulling tension (kg)

on pulley 0.2 T3 : Pulling tension before curve part (kg)

underground 0.2 - 0.3 T4 : Pulling tension after curve part (kg)

in pipe 0.5 - 0.7

Page - 90

Reference data on Aluminium conductor

Sheild cable ( XLPE/PVC-S etc )

Non Sheild cable ( XLPE/PVC etc )

Note) Sheild tape shall be

Sheild cable (XLPE/PVC-S etc)

300kg/m is suggested as permissible side wall pressure to the cable during installation.

θ

µ

T kg

r

LWT **2 eTT *43

Page 93: LV2009

Section 4 - Contents & Information

Fire Performance TestsFlame Propagation Tests IEC 60332-1Part 1 - Test on a single vertical insulated wire or cable This is a relatively simple method for providing adequate indication of the flame-retardant characteristics of a single cable.

A 600 mm long cable sample is verticatlly suspended, placed in the middle of a three-sided metal screen.

This is subjected to the regulated flame of one (up to a cable diameter of 50 mm) or two (above 50 mm diameter) gas burners at an

angle of 45° to the cable. The flame is applied for a continuous time calculated according to an increasing with the cable weight

(from around 1-minute for a small control cable to about 7 minutes for a 4 core 300 mm² power cable). The test is passed if the cable

has self-extinguished and the charred or flame affected portion of the cable has not reached the top of the sample.

IEC 60332-3Part 3 - Test on bunched wire or cablesThis test was developed to obtain a method to determine the flame propagation characteristics of bunched cables.

It can not be assumed that because a single vertical cable complies with the requirements of IEC 60332 part 1 it will also behave in

a similar manner when bunched with others cables.

The propagation of a flame along a bunch of cables depends on a number of features, such as :

The volume of combustible material exposed to the fire

The geometrical configuration of the cables

The temperature at which it is possible to ignite any gases emitted from the cables

The quantity of combustible gas released from the cables

The volume of air passing through the cable installation

The test consists of a vertical chamber, 1 x 2 x 4 m. Openings air inlet and outlet are provided in the base and the top of the test

chamber for a controlled air flow rate during the test. The cable samples to be tested are 3.5 m long and fixed to a steel ladder mounted

150 mm from the rear wall vertically with the test chamber. The number of lengths of cables in the test depends on the test categoty

based on the volume of combustible material.

Test Category Volume of combustible material Time of flame application

A 7 litres / m 40 Minutes

B 3.5 litres / m 40 Minutes

C 1.5 litres / m 20 Minutes

A ribbon gas burner of a set size and heat flow rate, operating at 800°C is mounted horizontally in front of the cable samples at a set

distance and height. The test is passed if the charred or affected portion of the samples have not reached a height exceeding 2.5 m

above the bottom edge of the burner.

IEC 60331 - 21 (1999)Fire resisting characteristics of electric cables Circuit Integrity TestThis test determines the circuit integrity of a cable during and after a prolonged fire :

A horizontally suspended sample 1200 mm long is placed 75 mm above a 610 mm long ribbon type gas burner, the flame temperature

of which is regulated to 750°C. The conductors of the sample are connected to an AC voltage source, at the operating voltage, via fuses.

The flame and test voltage shall be applied continuously for a period of 90 min. 12 hours after the flame has been extinguished the cable

is energised again.

The test is passed if no failure of any of the fuses occurs.

Page - 91

1

Page 94: LV2009

Section 4 - General Information

Page - 92

NOTES

Page 95: LV2009