lv live feeder and phase identifier

12
LV Live Feeder and Phase Identifier FC3000

Upload: al-buraq-hardware-tools-llc

Post on 27-Jun-2015

254 views

Category:

Technology


2 download

DESCRIPTION

Al Buraq Electric & Tools L.L.C ---- Your All in One Destination In 2004, when Al Buraq Hardware & Tools was started as a small family-owned business, we made a commitment to provide working people with great quality tools at the lowest prices. And for over 10 years, Al Buraq Hardware & Tools has done just that. From hand tools and generators, to air and power tools, from shop equipment to automotive tools, Al Buraq offers more than 20,000 tools and accessories at quality levels that match or exceed competing brands. We buy directly from the factories and we sell directly to you to enjoy the savings and the very high quality standards products. Now Al Buraq Hardware & Tools L.L.C in the UAE is following the guidance of HH Sheikh Mohamed Bin Rashed Al Maktoom to move Dubai Government to a smart Government we decided to have our E-SHOWROOM where the client can enjoy preparing the LPO directly from our website using his username and password. What do we have in our E-SHOWROOM? - Electrical Safety Products: industrial safety helmet for linemen, safety helmet for linemen with short visor, safety helmet with integrated face screen for electricians, Electrician face shield with headband and brow-guard, Arc-Flash protective face shield, helmet for use in the forestry industry, safety cap, glasses, headgears, safety shoes, safety boots, insulating mats, work gears, high-visibility garments, rain protection, climbing equipment, harnesses, energy absorbers, fall arresters, anchorage, connectors, lanyards, sets, rescue devices, latex gloves, composite chlorinated gloves, leather gloves, handling leather gloves, preliminary identification of cables and phases, no-voltage testing / absence of voltage testing, earthing and short-circuiting, earthing stickes, insulating tools 1000 V, cable cutters, shunt, repowering, network controlling and measuring equipment, substation equipment, (FAMECA, Sibille Safe, Jegou industries, Technowill) [email protected]

TRANSCRIPT

Page 1: LV live feeder and phase identifier

LV Live Feeder and Phase Identifier FC3000

Page 2: LV live feeder and phase identifier

LV Live Feeder and Phase Identifier FC3000

Page 3: LV live feeder and phase identifier

Line Unit leadsCentral Unit leads

Heavy duty case

Illustrated operating instruction in the lid Display on LCD screen with

a choice of many languages

Fuse protection on Central Unit (CU) and Line Unit (LU)

Fused leads

Fuse leads

Up to 12 Circuits/feeders

IP2X probes

LV Live Feeder and Phase Identifier FC3000

Page 4: LV live feeder and phase identifier

■ Functions of the LV Live Feeder and Phase Identifier

This device can be used by a single operator for mapping customer phase and feeder connection in 5 seconds.

Which are compulsory information to enable Smart Meters communication. Applications : Helps to balance the

loads on the phases of the low voltage network.

Simple to use : The Central Unit (CU) is connected to all the outgoing lines on a supply substation. The Line Unit (LU), connected to any points of the network (customer, connection box, …), automatically provides you with all the useful information : Local voltage measurement

Phase indication : L1, L2 or L3 Feeder or circuit : From 1 to 6 (9 or 12) Substation (CU code) : Form 1 to 8 Didactic operating mode on the Central

Unit Category IV device protected by HRC fuses Insulated connection accessories Built-in self-test Thanks to the CU unit code it is possible to

use simultaneously several CUs located in several substations.

LV Live Feeder and Phase Identifier FC3000

Page 5: LV live feeder and phase identifier

■ Specifications of the LV Live Feeder and Phase Identifier

Central Unit FC3000 UC Nominal voltage (phase-neutral) : 115 Vrms to 230

Vrms 200 Vrms to 400 Vrms between phases Maximum rated voltage : 440 Vrms (between phases, and

between phase en neutral) Minimum operating voltage : 200 Vrms between phases Network frequency : 50 or 60 Hz Input plugs L1-L2-L3-Neutral : Ø 4mm male IP2X (at the end

of the power lead) Functions : automatic and manual modes menus available in

6 languages Inputs protection : fast-acting HRC fuses in the housing and

at the leads connecting points Overvoltage category : 1000 V – Cat. IV Enclosure protection : IP51 (IP67 in closed case) Dimensions : 300 x 230 x 85mm Weight : 2.35 kg Detection coils : 6 for FC30006, 9 for FC30009, 12 for

FC300012 Identification : by colour coded ring (s) Loop diameter : Ø 120 mm

Line Unit : FC3000 UL Nominal voltage : 230 Vrms (between phase and neutral

terminals) Power supply : 4 alkaline batteries 1.5 V AA Autonomy : over 1000 detections Inputs protection : fast-acting HRC fuses in the housing and at

the IP2X leads connecting points Overvoltage Category : 1000 V – Cat. IV Enclosure protection : IP54 Approximate dimensions : 250 (235) x 130 x 65 mm Protection : shockproof rubber-type shell case Weight : 1.4 kg with shell case, lead, test probes and alligator

clips Complete unit

• Synthetic carry and storage case, IP67 when closed• Operating temperature : from 0°C to + 40°C / Hygrometry <

90 % non condensing.• Storage and transport temperature : from -20°C to + 70°C.

LV Live Feeder and Phase Identifier FC3000

Page 6: LV live feeder and phase identifier

■ Standard and Environment

CE marking: Compliant with European Directives EMC Directive (Electro Magnetic Compatibility) 89/336/EEC, 92/31/EEC,

93/68/EEC et 92-587/RF, 95-283/RF, standard EN 55011 edition 2009 + A1/2010

Low Voltage Safety Directive (Safety of low-voltage equipment ) 73/23/EEC et 75-848/RF standard IEC/EN 61010-1 ed. 3.0 (2010-06) IEC/EN 61010-031 ed.1.1 (2008-06)

LV Live Feeder and Phase Identifier FC3000

Smart Meter friendlyNo perturbations for CLC signalsCompliant with standard requirements EN

50065-1 edition 07-2012

Page 7: LV live feeder and phase identifier

All our products help utilities to face global challenges providing high safety level for electrical network improvement operations:Preparation / safetyEfficiency / Availability

THE NETWORK WILL CHANGE !

Page 8: LV live feeder and phase identifier

THE NETWORK WILL CHANGE !

Page 9: LV live feeder and phase identifier

THE NETWORK WILL CHANGE !

Page 10: LV live feeder and phase identifier

Work in total confidence

with your powernetwork

Page 11: LV live feeder and phase identifier

HISTORY & FIGURES

1949: creation of the company to supply earthing devices to “compagnie du Rhin”

1960: creation of the French LiveW competence Center (SERECT) in Mulhouse

1989: building of this building specialy designed around high voltage laboratory

1998: integration in Novarc Group 4800 m², 3500 references, TOP80% 1500 ref / 40 products 330 suppliers, 2M components, 200k end products ISO 9002 in 1996, ISO 9001 since 2002 Export rate > 65% in more than 100 countries

Page 12: LV live feeder and phase identifier

For Sales: [email protected]