luwa tmp and tmpc filters · 920 pressure drop (pd): recommended final pd: 450 pa ... fp-h12 fp-h11...

4
Luwa TMP and TMPC Filters ® The Superior Solution for Combustion Air Intake Systems New, fully sealed TMPC ver- sion for off-shore and coastal application Most comprehensive range – fully tested Large filter surfaces – extremely long service life Low pressure drop – maxi- mum power output Robust hollow profile plastic frame – high burst resist- ance Glass fibre paper medium – no fibre loss, no shedding Fully incinerable, recyclable materials Minimal weight and installa- tion depth Fits all commonly used filter frames

Upload: trankhanh

Post on 18-Apr-2018

254 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: Luwa TMP and TMPC Filters · 920 Pressure drop (pd): Recommended final pd: 450 Pa ... FP-H12 FP-H11 FP-H10 Luwa TMPC Filter Luwa Ultrafilter TMPC Type H10-610 H11-610 H12-610 Air

Luwa TMP and TMPC Filters®

The Superior Solution for CombustionAir Intake Systems

● New, fully sealed TMPC ver-sion for off-shore and coastalapplication

● Most comprehensive range –fully tested

● Large filter surfaces – extremely long service life

● Low pressure drop – maxi-mum power output

● Robust hollow profile plasticframe – high burst resist-ance

● Glass fibre paper medium –no fibre loss, no shedding

● Fully incinerable, recyclablematerials

● Minimal weight and installa-tion depth

● Fits all commonly used filterframes

Page 2: Luwa TMP and TMPC Filters · 920 Pressure drop (pd): Recommended final pd: 450 Pa ... FP-H12 FP-H11 FP-H10 Luwa TMPC Filter Luwa Ultrafilter TMPC Type H10-610 H11-610 H12-610 Air

100

50

90 99

10

Luwa Turbine Minipleat Filters – the superior solution

LuwaTMP filters remove airborne partic-ulate matter from combustion engine in-take air, providing full protection fromfouling, corrosion and erosion of the tur bines key components. TMP filters aremost suitable for gas turbines, dieselengines, compressors and air condi-tioning units for power plants, offeringlower pressure drop and extended life.The Luwa TMP filters are available in 7 efficiencies, two pleating densities andtwo designs. Used in combination withthe Luwa GS synthetic pocket filterrange, they offer optimised efficiency/life time relationship at the lowest pres-sure drop.

When selecting a combination of pre-filters and final filters, one should con-sider:● the co-ordination of the filters effcien-

cies,● the optimisation of the dust holding

capacity,● the minimisation of the overall system

pressure drop.

Tests confirm that the dust holding ca-pacity of the final filter is reduced withincreasing arrestance of the prefilter(see Fig. 1).

Is Cost Important to You?The cost performance of combined filterstages depends on the interaction ofthe filter efficiency of the prefilter withthat of the final filter and hence it’s ef-fect on the overall system dust holding

90 9995

2

Arrestance of Prefilter [%]Fig. 1

Overall Cost of Filter Outfit

➀ Prefilter only➁ Prefilter + F7 Final filter➂ Prefilter + F8 Final filter

Fig. 2 Arrestance of Prefilter [%]

AC-Fine Dust Holding Capacity of Final Filter [%]

Gas turbine airintake housing for515000 m3/h

For exemple:● GS-G3-K (125 mm) + TMP-F7:

120 Pa @ 3400 m3/h190 Pa @ 4250 m3/h

● GS-G4 (350 mm) + TMP-F8:150 Pa @ 3400 m3/h215 Pa @ 4250 m3/h

These low pressure drops – a typicalproperty of the Luwa filter systems –offer on one hand significant higher po-wer output of the engine and thus ashorter pay back period of the invest-ment. The high dust holding capacitieson the other hand assure low mainte-nance and replacement cost.

Luwa GS/TMP filters are designed for amodule air flow of 4250 m3/h (2500cfm). Compared with the traditional3400 m3/h (2000 cfm) units they offer20% space saving for a comparable lifeexpectancy. When traditional units witha module air flow of 3400 m3/h are ex-changed, the Luwa filter combinationtypically doubles the life.

capacity. For a given final filter efficiency,both a too low and a too high prefilterarrestance increase overall cost. Thehigher the efficiency of the final filterstage, the narrower is the resulting sec-tor for an optimal choice of the prefilterstage (see Fig. 2).

Based on these facts and on extensivepractical experiance, Luwa specialistsare happy to assist you in the selectionof optimal pre and final filter combina-tions, tailored to your local environmen-tal and operating conditions.

How We Reduce Your CostThe initial pressure drop of the LuwaTMP filter combination is extremely low.

Page 3: Luwa TMP and TMPC Filters · 920 Pressure drop (pd): Recommended final pd: 450 Pa ... FP-H12 FP-H11 FP-H10 Luwa TMPC Filter Luwa Ultrafilter TMPC Type H10-610 H11-610 H12-610 Air

250

200

150

100

70

50

40

30

2000 3000 4000 5000Air flow [m3/h] ➞

Initi

al p

ress

ure

drop

[Pa]

TMP-F9

TMP-F8

TMP-F6TMP-F7

Luwa TMP and TMPC Fine Dust Filters

Luwa TMP and TMPC fine dust filters are available in efficiency rates of 70, 86, 93, 96 and 98% to ASHRAE 52.1-92and in filter classes F6 to F9 to EN 779respectlvely. The mlcro glass flbre paperis mini pleated, formed into mats andsealed into a fully welded plastic framein a four-V arrangement. Unique hollowprofiles feature an extremely rigid andlight-weight filter (5.3 kg only). Maximumopen face area results in lowest pres- sure drop and extended filter mediumarea in maximum dust holding capacity.A fully potted HEPA-tigth version,TMPC, with conical plates for optimalwater dralnage is also avalable.Luwa TMP and TMPC fine dust filters,with the standard dimensions 592 x592 x 300 mm, are interchangeable withcommonly used filters and fit mostframes.

Application Parameters

Continuous operating temperature:● � 70 °C● High temperature version for up to

120 °C on request

3

Material Specification

Filter medium:micro glass-fibre bonded to paper

Filter frame:incinerable, halogen-free, recycledPolystyrol

Flammability classification:DIN 53438-K2/F2 and DIN 4102-B2Version with classification DIN 53438-K1/F1 (UL 900, Class 2) on request

Sealant:Polyurethane foam

Luwa Fine Dust Filter TMP and TMPC

Air flow VN (normal service life)Initial pressure drop at VN

Rated air flow VR (long service life)Initial pressure drop at VR

Filter class as per EN 779 (EN 1822) Efficiency, atmospheric, average 1)

Arrestance, gravimetic, average 1)

Type N: Filter medium areaASHRAE dust holding capacity 1)

AC-fine dust holding capacity 2)

Type E: Filter medium area ASHRAE dust holding capacity 1)

AC-fine dust holding capacity 2)

1) Tested to ASHRAE 52.1 and EN 779, for 3400 m3/h (2000 cfm) up to 450 Pa final pressure drop2) Tested on ASHRAE 52.1 test rig, for 4250 m3/h (2500 cfm) up to 600 Pa final pressure drop

Type

m3/hPa

m3/hPa

–%%

m2

gg

m2

gg

F6-610

425095

340065

F 67098

20750

1420

–––

F7-610

4250105

340070

F 786

>99

20624

1300

24724

1510

F8-610

4250125

340090

F 893

>99

20596

1030

24692

1200

F9-610

4250135

340095

F 996

~100

20564920

24655

1070

H10-610

3400140

3000120

(H 10)98

~100

20460790

24535920

Pressure drop (pd):● Recommended final pd: 450 Pa● Maximal final pd: 800 Pa● Burst pd (new filter): �2500 Pa

Admissible relative humidity:�100% for TMP� 100% for TMPC

Dimensions:see page 4

TMP-H10

Luwa TMP Filter

Page 4: Luwa TMP and TMPC Filters · 920 Pressure drop (pd): Recommended final pd: 450 Pa ... FP-H12 FP-H11 FP-H10 Luwa TMPC Filter Luwa Ultrafilter TMPC Type H10-610 H11-610 H12-610 Air

Luwa TMPC Ultrafilters are available innominal efficiency rates of 90%, 97%and 99.9% for 0.3 µm DOP to US Mil. Std. 282 and in filter classes H10, H11and H12 to EN 1822 respectively. They are designed in the same way as the TMPC fine dust filters, described onpage three.

Luwa TMPC Ultrafilters are designed tomeet the requirements of the latestgenerations of ultra-efficient GT's whichare very sensitive to submicron particles.The Ultrafilters are available in the fullypotted HEPA-tight TMPC version only,due to the higher tightness requirementsof the higher efficiencies.

For application parameters and material specifications see page 3

Air flow [m3/h] ➞

Initi

al p

ress

ure

drop

[Pa]

25

300

592

592

Dimensions in mm

Dimensions TMP/TMPC

FP-H12

FP-H11

FP-H10

Luwa TMPC Filter

Luwa Ultrafilter TMPC Type H10-610 H11-610 H12-610

Air flow VN (normal service life) m3/h 3400 3400 3400Initial pressure drop at VN Pa 140 180 295

Rated air flow VR (long service life) m3/h 3000 3000 3000Initial pressure drop at VR Pa 120 155 260

Filter class as per EN 1822 – H10 H11 H12Initial efficiency as per EN 1822 (MPPS-DEHS test) % � 85 � 95 � 99.5Initial efficiency as per US. Mil. Std. 282 (DOP test) % 90 97 99.9

Type E: Filter medium area m2 24 22 22Recommended class of prefiltration1) (EN 779) – F7 F8 F9