lumisphere

8
Low voltage display lighting Low voltage display lighting Heathrow Renovation 2011 - 2012

Upload: jonathan-hawkins

Post on 23-Jul-2015

823 views

Category:

Technology


1 download

TRANSCRIPT

Page 1: Lumisphere

Low voltage display lightingLow voltage display lighting

Heathrow Renovation 2011 - 2012

Page 2: Lumisphere

�Xenon festoon low voltage�LED festoon lighting�Bespoke lighting systems�Weatherproof Transformers and Driver units�Weatherproof Transformers and Driver units�Tree lighting systems

Page 3: Lumisphere

LED FESTOONS:Utilising lumisphere’s patented lampholder and polycarbonate globes, and system cable

� Durability

� Versatility

Retrofit LEDs:� You can now extend the life of tired

Lumisphere festoons by retrofitting with LED modules.

� Exceptionally long life saving on energy and maintenance costs.

� Versatility

� Endurance

� Low maintenance

and maintenance costs.

� Available in warm white , cool white, red, gree, amber and blue ultra bright Leds

� Flashing Modules are also available to create stunning seasonal effects

� See http://www.youtube.com/user/LumisphereProductsto see the flashing units in action

Page 4: Lumisphere

� Low maintenance, with approx 50,000hr life expectancy

� Low energy consumption

� Ultra Low Power consumption

� IP68 weatherproof

� Exceptional Long life

� Flexibility to incorporate � Flexibility to incorporate imaginative lighting schemes

Wembley

Eden Project

London Eye

Page 5: Lumisphere

� ULTRA highbrightness LEDs

� Wide angle light distribution

� Anticipated 50,000 hrs

� Available in Cool white, warm white, red, green, blue and amber

� Available in Cool white, warm white, red, green, blue and amber

� Flexibility to incorporate imaginative lighting schemes

Page 6: Lumisphere

� Available in 5w 8.5w & 10w

� High brightness

� Wide angle

� World renown system installed in many prestigious locations

� Anticipated 20,000 hrs

Lumisphere X24

festoon Systems

� Anticipated 20,000 hrs

� Flexibility to incorporate imaginative lighting schemes

Page 7: Lumisphere

Current ledsOrbical 360/8 chip

X24 8.5w

300

lights

Orbical 360/8

Energy comparisons based 300 light

units @ 2000 hrs per annum

300

lights

Current ledsOrbical 360/8

chipX24 8.5w

Voltage 0 0 0

Avg kw ph 0.255 0.3 2.55

Annual kw hrs 510 600 5100

Lamp life (hrs) 70,000 50,000 20,000

Annual Energy @ £0.13 £66.30 £78.00 £663.00

Page 8: Lumisphere

Kim Knight

Lumisphere Products ltd

Tel: 01245 329999

Fax: 01245 322600

Email: [email protected]